Inadvertent transposition of defibrillator coil terminal pins causing inappropriate ICD therapies.
Issa, Ziad F
2008-06-01
We report the case of a 65-year-old man with chronic atrial fibrillation (AF) and severe ischemic cardiomyopathy who underwent implantation of a prophylactic single-chamber implantable cardioverter-defibrillator (ICD). The patient experienced inappropriate ICD therapies due to oversensing of pectoral muscle myopotential secondary to reversal of the defibrillator coil terminal pins in the ICD header. Recognizing this possibility is important to avoid misinterpretation of spontaneous oversensing as hardware failure (e.g., lead fracture or insulation breech) and potentially unnecessary ICD system surgical intervention, including lead extraction.
Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C; Johansen, Jens B; Petersen, Helen H; Haarbo, Jens; Johansen, Martin B; Thøgersen, Anna Margrethe
2016-03-01
The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. The purpose of this study was to compare clinical outcomes in patients with single- and dual-coil leads. All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. Single-coil leads were associated with lower all-cause mortality with an adjusted hazard ratio of 0.85 (95% confidence interval 0.73-0.99; P = .04). This finding was robust in a supplementary propensity score-matched analysis. However, dual-coil leads were used in patients with slightly higher preimplant morbidity, making residual confounding by indication the most likely explanation for the observed association between lead type and mortality. The lowest successful defibrillation energy was higher using single-coil leads (23.2 ± 4.3 J vs 22.1 ± 3.9 J; P < .001). No significant differences were observed for other secondary end points showing high shock efficacies and low rates of lead failures and extraction complications. Shock efficacy is high for modern ICD systems. The choice between single-coil and dual-coil defibrillator leads is unlikely to have a clinically significant impact on patient outcomes in routine ICD implants. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Hauser, Robert G.; Katsiyiannis, William T.; Gornick, Charles C.; Almquist, Adrian K.; Kallinen, Linda M.
2010-01-01
Aims An estimated 10 000–15 000 pacemaker and implantable cardioverter–defibrillator (ICD) leads are extracted annually worldwide using specialized tools that disrupt encapsulating fibrous tissue. Additional information is needed regarding the safety of the devices that have been approved for lead extraction. The aim of this study was to determine whether complications due to device-assisted lead extraction might be more hazardous than published data suggest, and whether procedural safety precautions are effective. Methods and results We searched the US Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database from 1995 to 2008 using the search terms ‘lead extraction and death’ and ‘lead extraction and injury’. Additional product specific searches were performed for the terms ‘death’ and ‘injury’. Between 1995 and 2008, 57 deaths and 48 serious cardiovascular injuries associated with device-assisted lead extraction were reported to the FDA. Owing to underreporting, the FDA database does not contain all adverse events that occurred during this period. Of the 105 events, 27 deaths and 13 injuries occurred in 2007–2008. During these 2 years, 23 deaths were linked with excimer laser or mechanical dilator sheath extractions. The majority of deaths and injuries involved ICD leads, and most were caused by lacerations of the right atrium, superior vena cava, or innominate vein. Overall, 62 patients underwent emergency surgical repair of myocardial perforations and venous lacerations and 35 (56%) survived. Conclusion These findings suggest that device-assisted lead extraction is a high-risk procedure and that serious complications including death may not be mitigated by emergency surgery. However, skilled standby cardiothoracic surgery is essential when performing pacemaker and ICD lead extractions. Although the incidence of these complications is unknown, the results of our study imply that device-assisted lead extractions should be performed by highly qualified physicians and their teams in specialized centres. PMID:19946113
Howe, Andrew J; McKeag, Nicholas A; Wilson, Carol M; Ashfield, Kyle P; Roberts, Michael J
2015-06-01
Implantable cardioverter defibrillator (ICD) lead insulation failure and conductor externalization have been increasingly reported. The 7.8F silicon-insulated Linox SD and Linox S ICD leads (Biotronik, Berlin, Germany) were released in 2006 and 2007, respectively, with an estimated 85,000 implantations worldwide. A 39-year-old female suffered an out-of-hospital ventricular fibrillation (VF) arrest with successful resuscitation. An ICD was implanted utilizing a single coil active fixation Linox(Smart) S lead (Biotronik, Berlin, Germany). A device-triggered alert approximately 3 years after implantation confirmed nonphysiological high rate sensing leading to VF detection. A chest X-ray showed an abnormality of the ICD lead and fluoroscopic screening confirmed conductor externalization proximal to the defibrillator coil. In view of the combined electrical and fluoroscopic abnormalities, urgent lead extraction and replacement were performed. A review of Linox (Biotronik) and Vigila (Sorin Group, Milan, Italy) lead implantations within our center (n = 98) identified 3 additional patients presenting with premature lead failure, 2 associated with nonphysiological sensed events and one associated with a significant decrease in lead impedance. All leads were subsequently removed and replaced. This case provides a striking example of insulation failure affecting the Linox ICD lead and, we believe, is the first to demonstrate conductor externalization manifesting both electrical and fluoroscopic abnormalities. © 2015 Wiley Periodicals, Inc.
Nazmul, Mohammed N; Cha, Yong-Mei; Lin, Grace; Asirvatham, Samuel J; Powell, Brian D
2013-03-01
Pacemaker and implantable cardioverter-defibrillator (ICD) leads can cause tricuspid valve regurgitation (TR). Few data are available on the best management of significant TR that develops after pacemaker or ICD implantation and regarding any benefits of right ventricular (RV) lead extraction. We sought to determine the impact of RV lead removal on lead-induced TR. We reviewed all patients between 1 January 2000 and 31 December 2010 at the tertiary care hospital who had a preoperative indication of TR and underwent percutaneous extraction of an RV lead with the intent of trying to correct moderate or severe TR. Pre- and post-procedure echoes and clinical data were retrospectively reviewed. In the four patients identified, the RV lead was removed and placed in the coronary sinus to try to improve moderate or severe TR due to lead impingement. There was no significant improvement in the degree of TR except one patient where TR improved slightly from moderate to mild-moderate. All patients had a dilated tricuspid valve annulus by the time of lead extraction. Tricuspid annulus dilatation appeared to account for the persistent TR after RV lead removal. A greater degree of tricuspid valve annulus dilatation may be a marker and mechanism for irreversible lead-induced TR. Further studies are needed to determine whether surgical tricuspid valve repair or replacement combined with RV lead extraction would result in better outcomes than a percutaneous lead extraction approach.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-02-16
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.
De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano
2017-01-01
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a “unique” failure mechanism: Cables externalize through the insulation (“inside-out” abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads. PMID:28255544
Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav
2017-09-01
Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Hsu, Jonathan C; Saxon, Leslie A; Jones, Paul W; Wehrenberg, Scott; Marcus, Gregory M
2015-08-01
Historically, the most commonly implanted implantable cardioverter-defibrillator (ICD) lead is dual coil. Conventional wisdom holds that single-coil leads may be less effective than dual-coil leads, but easier to extract. No contemporary large-scale studies have evaluated the relative epidemiology of these 2 leads or compared their respective clinical outcomes. We sought to evaluate trends in single- vs dual-coil ICD lead implantation and differences in clinical outcomes. We evaluated 129,520 ICD recipients enrolled in the LATITUDE remote monitoring system between 2004 and 2014. Kaplan-Meier analyses and Cox proportional hazards regression analyses were used for univariate and multivariate survival analysis, respectively. The majority of ICD recipients received a dual-coil lead (n = 110,330 [85.2%]). Single-coil lead implantation increased from 1.9% to 55.2% between 2004 and 2014. After adjusting for age, sex, device type, and year of implant, single-coil lead implantation was associated with a greater odds of induction for defibrillation testing (odds ratio 1.05; 95% confidence interval [CI] 1.01-1.09; P = .0274), a higher rate of lead being taken out of service (hazard ratio 1.19; 95% CI 1.06-1.33; P = .0032), and a decreased mortality rate (hazard ratio 0.91; 95% CI 0.87-0.96; P = .0004). In a 795 patient subset with adjudicated shock outcomes, first shock success was no different (87.0% in single coil vs 86.1% in dual coil; P = .8473). In a large real-world US population, single-coil lead implantation rates increased substantially between 2004 and 2014. Single-coil lead implantation was associated with more frequent defibrillation testing and the lead being taken out of service, but was not associated with increased mortality or more frequent defibrillation failure. Copyright © 2015 Heart Rhythm Society. All rights reserved.
Generator replacement is associated with an increased rate of ICD lead alerts.
Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J
2014-10-01
Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Implantable Cardiac Defibrillator Lead Failure and Management.
Swerdlow, Charles D; Kalahasty, Gautham; Ellenbogen, Kenneth A
2016-03-22
The implantable-cardioverter defibrillator (ICD) lead is the most vulnerable component of the ICD system. Despite advanced engineering design, sophisticated manufacturing techniques, and extensive bench, pre-clinical, and clinical testing, lead failure (LF) remains the Achilles' heel of the ICD system. ICD LF has a broad range of adverse outcomes, ranging from intermittent inappropriate pacing to proarrhythmia leading to patient mortality. ICD LF is often considered in the context of design or construction defects, but is more appropriately considered in the context of the finite service life of a mechanical component placed in chemically stressful environment and subjected to continuous mechanical stresses. This clinical review summarizes LF mechanisms, assessment, and differential diagnosis of LF, including lead diagnostics, recent prominent lead recalls, and management of LF and functioning, but recalled leads. Despite recent advances in lead technology, physicians will likely continue to need to understand how to manage patients with transvenous ICD leads. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Wearable Cardioverter Defibrillators.
Ferrick, Aileen M; Tian, David; Vudathaneni, Vijaya; Shevchuk, Olga L; Ferrick, Neal J; Frishman, William
The use of implantable cardioverter defibrillators (ICD) has favorably impacted the prevention and treatment of sudden cardiac death (SCD) associated with ventricular arrhythmias. However, there are situations where an ICD cannot be immediately implanted, even though the patient is at high risk for SCD. The wearable cardioverter defibrillator (WCD) is a unique technology that can bridge this gap for patients. The WCD has been demonstrated to terminate ventricular tachycardia/fibrillation if worn and used correctly. With proper training, it is relatively easy to put on, maintain, and use. Most patients are compliant and are able to consistently wear the device. The WCD negates the infection risk or procedural complications associated with insertion and possible extraction of leads, as with an ICD. In terms of primary prevention of ventricular tachycardia/fibrillation in patients with a left ventricular ejection fraction ≤35%, prospective, randomized studies evaluating the survival of patients utilizing the WCD will need to be performed before evidenced-based criteria for its use can be established. On the basis of current data, WCD use for those awaiting heart transplant, for those with ICD indications status post-ICD explant, and for high-risk SCD patients with possible reversible cardiomyopathy appears to be a reasonable approach on the basis of current data.
Kavuluru, Ramakanth; Han, Sifei; Harris, Daniel
2017-01-01
Diagnosis codes are extracted from medical records for billing and reimbursement and for secondary uses such as quality control and cohort identification. In the US, these codes come from the standard terminology ICD-9-CM derived from the international classification of diseases (ICD). ICD-9 codes are generally extracted by trained human coders by reading all artifacts available in a patient’s medical record following specific coding guidelines. To assist coders in this manual process, this paper proposes an unsupervised ensemble approach to automatically extract ICD-9 diagnosis codes from textual narratives included in electronic medical records (EMRs). Earlier attempts on automatic extraction focused on individual documents such as radiology reports and discharge summaries. Here we use a more realistic dataset and extract ICD-9 codes from EMRs of 1000 inpatient visits at the University of Kentucky Medical Center. Using named entity recognition (NER), graph-based concept-mapping of medical concepts, and extractive text summarization techniques, we achieve an example based average recall of 0.42 with average precision 0.47; compared with a baseline of using only NER, we notice a 12% improvement in recall with the graph-based approach and a 7% improvement in precision using the extractive text summarization approach. Although diagnosis codes are complex concepts often expressed in text with significant long range non-local dependencies, our present work shows the potential of unsupervised methods in extracting a portion of codes. As such, our findings are especially relevant for code extraction tasks where obtaining large amounts of training data is difficult. PMID:28748227
Roche, N-C; Stefuriac, M; Dumitrescu, N; Charbonnel, A; Godreuil, C; Bonnevie, L
2015-02-01
Implantable cardioverter defibrillator (ICD) is well-recognized therapy to prevent sudden cardiac death. Classic ICD need the use of permanent endocavitary leads, which may cause serious troubles (lead dislodgement, ventricular perforation, lead infections, etc.). The subcutaneous implantable cardioverter defibrillator (S-ICD) is a new device provided by only a subcutaneous lead. It has been developed for the last five years and it is becoming at present a real alternative to classic ICD. We report a clinical case of a 34 y.o. woman who presented a sudden cardiac death and who benefited the implantation of this new technology. This paper deals with the potential indications, usefulness benefits, and problems of the S-ICD. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Acute evaluation of transthoracic impedance vectors using ICD leads.
Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils
2009-06-01
Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.
Santharam, Sandhya; Hudsmith, Lucy; Thorne, Sara; Clift, Paul; Marshall, Howard; De Bono, Joseph
2017-03-01
Ventricular arrhythmias are a major cause of mortality in adult congenital heart disease (ACHD) patients. The European Society of Cardiology guidelines state that implantable cardioverter-defibrillators (ICD) should be considered in patients with congenital heart disease following spontaneous sustained ventricular tachycardia (VT) or cardiac arrest and in patients at presumed high risk. This study sought to analyse the circumstances in which ACHD patients received ICD and to assess outcomes of ICD implantation, including therapies delivered and the rate of complications. A retrospective review was performed of all adult patients with congenital heart disease undergoing ICD implant between 2000 and 2014, in a large quaternary referral centre with over 4000 adults with congenital heart disease under active follow-up. Demographics: 42 patients with congenital heart disease had ICD implants: 55% male; age range 21-71 years and mean age 45 years. Mean age at implantation of ICD was 41 years. Mean follow-up was 5 years. Diagnosis: 50% of patients had repaired tetralogy of Fallot (TOF). Twelve per cent of patients had repaired transposition of the great arteries. Reason for ICD: 15 patients (35.7%) received ICD after sustained VT. Eleven patients (26.2%) received ICD after cardiac arrest. Sixteen (38%) had ICD implanted as primary prophylaxis. Outcome: Since implantation, six patients received an appropriate full-output shock for VT from ICD. Nineteen (45%) patients suffered significant complications (inappropriate shocks 11, inappropriate anti-tachycardia pacing resulting in VF 1, infection requiring extraction 3, lead abnormalities 3, and pneumothorax 1). Equal proportions of primary and secondary prevention patients received appropriate shocks. Most patients had ICD for secondary prevention (62%), and the majority had repaired TOF. There was a 2.9% annual appropriate shock rate. However, there was a high incidence of complications with more than a third suffering a major complication (9% per annum). The risks and benefits of ICD implantation are patient and disease specific, and must be clearly discussed prior to implantation. Further research is warranted into the use of primary prevention ICD in ACHD and in alternatives to ICD such as ablation in specific patient groups. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Singh-Manoux, Archana; Kivimäki, Mika; Sjösten, Noora; Ferrie, Jane E; Nabi, Hermann; Pentti, Jaana; Virtanen, Marianna; Oksanen, Tuula; Vahtera, Jussi
2010-08-01
It is unclear whether individuals experience specific patterns of morbidity prior to premature death from cardiovascular disease (CVD). We examined morbidity levels in the 6 years leading up to death from CVD in 37,397 men and 113,198 women under 65 years of age from the Finnish Public Sector study, with a particular focus on gender differences. Morbidity was assessed using lost days from work, extracted from register data on sickness leave and disability pension. Data on cause-specific mortality were obtained from national health registers. During a median follow-up of 8.5 years, there were 361 CVD deaths (174 from ischaemic heart disease (ICD9 410-414, 427.5; ICD10 I21-I25, I46), 91 from stroke (ICD9 430, 431, 434; ICD10 I60-I60, I61, I63), and 96 from other diseases of circulatory system (ICD9 390-459; ICD10 I00-I99)). Women had lower morbidity than men over the 6 years preceding stroke deaths (RR for mean annual days=0.33 (95% CI 0.14-0.78)). For other causes of CVD mortality, there were no gender differences in morbidity rates prior to death. In men, those who died from CVD had substantially greater morbidity levels than matched controls through the entire 6-year period preceding death (rate ratio=3.59; 95% confidence interval 2.62-4.93). Among women, morbidity days were greater particularly in the year preceding death from stroke. Our results on working age men and women suggest no gender differences in morbidity prior to death from heart disease and lower morbidity in women prior to death from stroke. These findings challenge the widespread belief that women experience more morbidity symptoms than men. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Clinical performance of different DF-4 implantable cardioverter defibrillator leads.
Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean
2018-06-01
Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P = 0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.
Reconstruction of an 8-lead surface ECG from two subcutaneous ICD vectors.
Wilson, David G; Cronbach, Peter L; Panfilo, D; Greenhut, Saul E; Stegemann, Berthold P; Morgan, John M
2017-06-01
Techniques exist which allow surface ECGs to be reconstructed from reduced lead sets. We aimed to reconstruct an 8-lead ECG from two independent S-ICD sensing electrodes vectors as proof of this principle. Participants with ICDs (N=61) underwent 3minute ECGs using a TMSi Porti7 multi-channel signal recorder (TMS international, The Netherlands) with electrodes in the standard S-ICD and 12-lead positions. Participants were randomised to either a training (N=31) or validation (N=30) group. The transformation used was a linear combination of the 2 independent S-ICD vectors to each of the 8 independent leads of the 12-lead ECG, with coefficients selected that minimized the root mean square error (RMSE) between recorded and derived ECGs when applied to the training group. The transformation was then applied to the validation group and agreement between the recorded and derived lead pairs was measured by Pearson correlation coefficient (r) and normalised RMSE (NRMSE). In total, 27 patients with complete data sets were included in the validation set consisting of 57,888 data points from 216 full lead sets. The distribution of the r and NRMSE were skewed. Mean r=0.770 (SE 0.024), median r=0.925. NRMSE mean=0.233 (SE 0.015) median=0.171. We have demonstrated that the reconstruction of an 8-lead ECG from two S-ICD vectors is possible. If perfected, the ability to generate accurate multi-lead surface ECG data from an S-ICD would potentially allow recording and review of clinical arrhythmias at follow-up. Copyright © 2017 Elsevier B.V. All rights reserved.
Tsurugi, Takuo; Matsui, Shogo; Nakajima, Hiroshi; Nishii, Nobuhiro; Honda, Toshihiro; Kaneko, Yoshiaki
2015-06-01
An electrical short circuit is a rare complication in a high-voltage implantable cardioverter-defibrillator (ICD). However, the inability of an ICD to deliver appropriate shock therapy can be life-threatening. During the last 2 years, four cases of serious complications related to an electrical short circuit have been reported in Japan. A spark due to an electrical short circuit resulted in the failure of an ICD shock to terminate ventricular tachycardia and total damage to the ICD generator in three of four cases. Two of the four patients died from an electrical short circuit between the right ventricle and superior vena cava (SVC) leads. The others had audible sounds from the ICD generator site and were diagnosed with a lead-to-can abrasion, which was manifested by the arc mark on the surface of the can. It is still difficult to predict the occurrence of an electrical short circuit in current ICD systems. To reduce the probability of an electrical short circuit, we suggest the following: (i) avoid lead stress at ICD implantation, (ii) select a single-coil lead instead of a dual-coil lead, or (iii) use a unique algorithm which automatically disconnect can or SVC lead from shock deliver circuit when excessive current was detected. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.
Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M
2018-02-24
The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P < 0.001). Four subjects (6%) passed screening using the ECG machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.
Sideris, Skevos; Archontakis, Stefanos; Gatzoulis, Konstantinos A; Anastasakis, Aristotelis; Sotiropoulos, Ilias; Arsenos, Petros; Kasiakogias, Alexandros; Terentes, Dimitrios; Trachanas, Konstantinos; Paschalidis, Eleftherios; Tousoulis, Dimitrios; Kallikazaros, Ioannis
The introduction of an implantable cardioverter defibrillator (ICD) in clinical practice has revolutionized our therapeutic approach for both primary and secondary prevention of sudden cardiac death (SCD), as it has proven to be superior to medical therapy in treating potentially life-threatening ventricular arrhythmias and has resulted in reduced mortality rates. However, implantation of a conventional ICD carries a non-negligible risk of periprocedural and long-term complications associated with the transvenous ICD leads. The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) has recently emerged as a therapeutic alternative to the conventional ICD for patients with various cardiopathies and who are at high risk of SCD. The main advantage is the avoidance of vascular access and thus avoidance of complications associated with transvenous leads. Patients without pacing indications, such as bradycardia, a need for antitachycardia pacing or cardiac resynchronization, as well as those at higher risk of complications from transvenous lead implantation are perfect candidates for this novel technology. The subcutaneous ICD has proven to be equally safe and effective compared to transvenous ICD systems in early clinical trials. Further technical improvements of the system will likely lead to the expansion of indications and widespread use of this technology. In the present review, we discuss the indications for this system, summarize early clinical experiences and highlight the advantages and disadvantages of this novel technology. In addition, we present the first two cases of subcutaneous cardioverter defibrillator system implantation in Greece. Copyright © 2017 Hellenic Society of Cardiology. Published by Elsevier B.V. All rights reserved.
El Garhy, Mohammad; Ohlow, Marc-Alexander; Lauer, Bernward
Shock coil interaction in patients with multiple implantable cardioverter defibrillator (ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil interaction and its clinical relevance. All ICD patients (646 patients) who came to follow up control in our ICD ambulance between January 1, 2011, and December 31, 2011 in the department of cardiology in Bad Berka hospital were retrospectively evaluated in this study. All baseline demographic, clinical, and procedural characteristics and postoperative chest x ray in postero-anterior and lateral view as well as clinical and ICD follow up data were evaluated. Among 646 patients 42 had multiple ICD leads (6.5%) of whom 36 patients (5.5% of total cohort patients and 85.7% of patients with multiple ICD leads) had shock coil interaction and presented the study group (Group I). The control group (Group II) consisted of 610 patients without coil-coil interaction including patients with single shock lead (604 patients) or patients with multiple leads but without interaction between shock coils (6 patients). Inappropriate anti-tachycardia therapies and RV lead revisions were more frequent in patients with interaction between shock coils (Group I vs Group II: 27.7% and 5.7%; p = 0.049 and 30.6% vs 6.4; p = 0.0001, respectively). Interaction between shock coils may be one of possible causes of lead failure and resulted in inappropriate therapies and subsequent lead revision. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.
Lovelock, Joshua D; Premkumar, Ajay; Levy, Mathew R; Mengistu, Andenet; Hoskins, Michael H; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel R; Langberg, Jonathan J; Delurgio, David B
2015-12-01
St. Jude Riata/Riata ST defibrillator leads (St. Jude Medical, Sylmar, CA, USA) were recalled by the Food and Drug Administration in 2011 for an increased rate of failure. More than 227,000 leads were implanted and at least 79,000 patients still have active Riata leads. Studies have examined clinical predictors of lead failure in Riata leads, but none have addressed the effect of implantable cardioverter defibrillator (ICD) generator exchange on lead failure. The purpose of this study is to assess the effect of ICD generator exchange on the rate of electrical failure in the Riata lead at 1 year. A retrospective chart review was conducted in patients who underwent implantation of a Riata/Riata ST lead at one center. Patients with a functioning Riata lead (with/without externalized conductor) at the time of ICD exchange were compared to controls with Riata leads implanted for a comparable amount of time who did not undergo generator replacement. Riata leads were implanted in 1,042 patients prior to the recall and 153 of these patients underwent generator exchange without lead replacement. Conductor externalization was noted in 21.5% of Riata leads in the ICD exchange cohort, which was not different from the control group (19.2%; P = 0.32). Two leads failed in the first year after generator replacement (1.5%) which did not significantly differ from the control group (2.0%; P = 0.57). At change-out, 54% received a commanded shock (18.6 ± 0.9 J) that did not result in any change in the high-voltage lead impedance (46.1 ± 1.1 ohms). Conductor externalization was seen frequently in our cohort of patients. ICD generator exchange did not accelerate the rate of Riata lead failure at 1 year. Although both the control and the change-out cohorts failed at a rate much greater than nonrecalled leads, generator exchange did not appear to add to the problem. ©2015 Wiley Periodicals, Inc.
Ploux, Sylvain; Swerdlow, Charles D; Strik, Marc; Welte, Nicolas; Klotz, Nicolas; Ritter, Philippe; Haïssaguerre, Michel; Bordachar, Pierre
2018-06-02
Recognition of implantable cardioverter defibrillator (ICD) lead malfunction before occurrence of life threatening complications is crucial. We aimed to assess the effectiveness of remote monitoring associated or not with a lead noise alert for early detection of ICD lead failure. From October 2013 to April 2017, a median of 1,224 (578-1,958) ICD patients were remotely monitored with comprehensive analysis of all transmitted materials. ICD lead failure and subsequent device interventions were prospectively collected in patients with (RMLN) and without (RM) a lead noise alert (Abbott Secure Sense™ or Medtronic Lead Integrity Alert™) in their remote monitoring system. During a follow-up of 4,457 patient years, 64 lead failures were diagnosed. Sixty-one (95%) of the diagnoses were made before any clinical complication occurred. Inappropriate shocks were delivered in only one patient of each group (3%), with an annual rate of 0.04%. All high voltage conductor failures were identified remotely by a dedicated impedance alert in 10 patients. Pace-sense component failures were correctly identified by a dedicated alert in 77% (17 of 22) of the RMLN group versus 25% (8 of 32) of the RM group (P = 0.002). The absence of a lead noise alert was associated with a 16-fold increase in the likelihood of initiating either a shock or ATP (OR: 16.0, 95% CI 1.8-143.3; P = 0.01). ICD remote monitoring with systematic review of all transmitted data is associated with a very low rate of inappropriate shocks related to lead failure. Dedicated noise alerts further reduce inappropriate detection of ventricular arrhythmias. © 2018 Wiley Periodicals, Inc.
Long-term single-center experience of defibrillator therapy in children and adolescents.
Frommeyer, Gerrit; Feder, Sebastian; Bettin, Markus; Debus, Volker; Köbe, Julia; Reinke, Florian; Uebing, Anselm; Eckardt, Lars; Kehl, Hans Gerd
2018-06-01
Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes. Copyright © 2017 Elsevier B.V. All rights reserved.
Janson, Christopher M; Patel, Akash R; Bonney, William J; Smoots, Karen; Shah, Maully J
2014-01-21
This study aimed to investigate the impact of lead diameter and design on implantable cardioverter-defibrillator (ICD) lead survival in children and young adults. Recent reports have called attention to high rates of lead failure in adults with small-diameter ICD leads, but data in the pediatric population is limited. We reviewed lead performance in consecutive subjects ≤30 years with transvenous right ventricular ICD leads implanted at our center between January 1995 and October 2011. Lead failure was defined as fracture, perforation, or sensing failure necessitating revision. A total of 120 ICD leads were implanted in 101 patients at a mean age of 15.5 ± 4.9 years. There were 47 small-diameter (≤8-F) and 73 standard-diameter (>8-F) leads. During a median follow-up of 28.7 months (interquartile range: 14.4 to 59.2 months), there were 25 lead failures (21% prevalence), with an incidence of 5.6%/year (95% confidence interval: 3.4 to 7.8). Sprint Fidelis (SF) (Medtronic, Inc., Minneapolis, Minnesota) leads had lower 3-year (69% vs. 92%, p < 0.01) and 5-year (44% vs. 86%, p < 0.01) survival probabilities than standard-diameter leads. In multivariate Cox regression, SF design conferred the greatest hazard ratio for lead failure (hazard ratio: 4.42, 95% confidence interval: 1.73 to 11.29, p < 0.01). Age and linear growth were not significantly associated with lead failure. In this single-center pediatric study that evaluated lead diameter, lead design, and patient factors, the SF design conferred the highest risk of lead failure, suggesting that design rather than diameter is the critical issue in ICD lead performance. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Neuzil, Petr; Reddy, Vivek Y; Merkely, Bela; Geller, Laszlo; Molnar, Levente; Bednarek, Jacek; Bartus, Krzysztof; Richey, Mark; Bsee, T J Ransbury; Sanders, William E
2014-02-01
A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). The intravascular defibrillator has DFTs similar to those of commercially available ICDs. Published by Heart Rhythm Society on behalf of Heart Rhythm Society.
Insulation defects in Riata implantable cardioverter-defibrillator leads.
Sato, Akinori; Chinushi, Masaomi; Iijima, Kenichi; Izumi, Daisuke; Furushima, Hiroshi
2012-01-01
The structures composing implantable cardioverter-defibrillator (ICD) leads have become more complicated and thinner with technological advances. Silicon insulation defects with and without clinically manifested electrical abnormalities have been reported in Riata leads (St. Jude Medical). The aim of this study was to assess the incidence and clinical implications of insulation defects in Riata leads implanted at our hospital. The subjects included 10 consecutive patients who received 8-French Riata ICD leads with dual-coil conductors (model 1580 or 1581) between 2006 and 2010 at our hospital. Operative records, chest X-rays and interrogation data were reviewed. In all cases, Atlas+ (St. Jude Medical) was used as an ICD generator and the Riata leads were implanted transvenously and fixed to the right ventricular apex. During a mean follow-up period of 52±9 (36-70) months, chest X-rays revealed insulation defects in Riata leads and conductor wires projecting from the bodies of the Riata leads in two of 10 (20%) patients. One of the patients received inappropriate ICD therapies due to T-wave oversensing based on attenuation of R waves and augmentation of T waves 41 months after implantation. In the other patient, an insulation defect without any clinically manifested electrical troubles was detected 50 months after implantation. Riata leads have a high incidence of insulation defects, which may be occasionally accompanied by inappropriate ICD discharges. For patients with Riata leads, careful observation of any changes in the lead-electrical measurements and a routine chest X-ray follow-up are necessary.
Fuchs, S M; Schliemann-Willers, S; Fischer, T W; Elsner, P
2005-01-01
In the present study, we evaluated the protective action of cream preparations containing seven different types of marigold and rosemary extracts in vivo in healthy volunteers with experimentally induced irritant contact dermatitis (ICD). Marigold and rosemary extracts in base cream DAC (Deutscher Arzneimittel-Codex = German Pharmaceutical Codex) were tested in a 4-day repetitive irritation test using sodium lauryl sulfate. The effect was evaluated visually and quantified by noninvasive bioengineering methods, namely chromametry and tewametry. When the test products were applied parallel to the induction period of ICD, a statistically significant protective effect of all cream preparations was observed by all methods. This effect, although not statistically significant, was superior to control by undyed marigold und faradiol ester-enriched extracts in chromametry and by dyed and undyed rosemary extracts in tewametry. The sequential treatment (postirritation) once a day for 5 days was without any effect. Thus, a protective effect of some marigold and rosemary extracts against ICD could be shown in the elicitation phase. Copyright (c) 2005 S. Karger AG, Basel.
Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A
2006-02-01
Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was <0.35 mV-mV, then the detected rhythm was considered noise due to a lead failure. The first ICD-detected episode of lead failure and inappropriate detection from 24 ICD patients with a pace/sense lead failure and all ventricular arrhythmias from 56 ICD patients without a lead failure were selected. The stored data were analyzed to determine the sensitivity and specificity of the algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.
Kolb, Christof; Solzbach, Ulrich; Biermann, Jürgen; Semmler, Verena; Kloppe, Axel; Klein, Norbert; Lennerz, Carsten; Szendey, Istvan; Andrikopoulos, George; Tzeis, Stylianos; Asbach, Stefan
2014-07-01
Detrimental effects of right ventricular (RV) apical pacing have directed the interest toward alternative pacing sites such as the RV mid-septum. As safety data are scarce for implantable cardioverter defibrillator (ICD) recipients the study aims to evaluate ICD lead performance in the mid-septal position. A total of 299 ICD recipients (79% male, aged 65.2 ± 12.1 years, 83% primary prevention of sudden cardiac death) were randomized to receive the RV ICD electrode either in a mid-septal (n=145) or apical (n=154) location. Event-free survival was evaluated at 3 (primary endpoint) and 12 months (secondary endpoint). Events included a composite of lead revision, suboptimal right ventricular electrode performance (including defibrillation thresholds (DFT)>25 J) or lead position not in accordance with randomized location. Event-free survival at 3 (12) months was observed in 80.6% (72.3%) of patients randomized to a mid-septal and in 82.2% (72.1%) of patients randomized to an apical lead position, p=0.726 (p=0.969). Pre-defined margins for non-inferiority were not reached at 3 or 12 months. High DFT was found in 7 patients (5.0%) of the mid-septal and in 3 (2.2%) patients of the apical group (p=0.209). In ICD recipients electrode positioning to the RV mid-septum or the RV apex results in slightly different rates concerning the survival free of lead revision, suboptimal right ventricular electrode performance or non-randomized lead position. Non-inferiority of the mid-septal lead location cannot be concluded. This should be taken into consideration when a mid-septal lead position is pursued. ClinicalTrials.gov identifier NCT00745745. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather
2016-06-01
Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.
Schneider, Andrew E; Burkhart, Harold M; Ackerman, Michael J; Dearani, Joseph A; Wackel, Philip; Cannon, Bryan C
2016-09-01
Young patients have high rates of implantable cardioverter-defibrillator (ICD) lead fractures and are at risk for venous occlusion or tricuspid regurgitation with transvenous lead placement. Epicardial ICDs have the potential to circumvent complications associated with transvenous ICDs, but the literature on young patients remains limited. The purpose of this study was to evaluate the results of a minimally invasive epicardial ICD lead placement approach in young patients. A retrospective, institutional review board-approved electronic medical record review of all patients undergoing epicardial ICD placement at our institution from January 2011 to December 2015 was performed. A total of 46 patients (20 female [43%]; mean age 10.3 years, range 0.7-18.2 years; mean weight 41 ± 21 kg) were identified; 24 (52%) were ≤10 years old. A minithoracotomy was used in 28 patients (61%). All had acceptable defibrillation, right ventricular sensing, and stimulation thresholds. Median follow-up was 2.0 ± 1.3 years (range 0.02-4.5 years). Eight surgical complications occurred in 7 patients (15%), and 8 device-related complications occurred in 6 patients (13%). Fifty-eight appropriate shocks were delivered in 7 patients (15%). Four patients received inappropriate shocks in relation to lead fractures/microfractures. One patient in this cohort who had long QT syndrome type 8 died of a hypoglycemic seizure. Minimally invasive epicardial ICD placement provides an effective, alternative method for implanting an ICD system, particularly in very young patients (<6 years of age) or patients who are concerned about cosmetic appearance. This technique is an acceptable alternative to traditional transvenous ICD placement. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Zhu, Ye; Gu, Xiang; Xu, Chao
2017-10-16
Implantable cardioverter defibrillators (ICD) are capable of effectively terminating malignant ventricular arrhythmia and are the most effective way to prevent sudden cardiac death. However, some evidences demonstrated that both anti-tachycardia pacing (ATP) and ICD shock can also bring adverse prognosis. A 66-year-old Han Chinese man with prior ICD implantation was admitted to our hospital because of frequent ICD shocks. Although intravenous amiodarone and esmolol succinate were administered daily, the patient suffered 155 episodes of VT/VF during 8 weeks after implantation. After repeated discharge of the device, the pacing threshold of the patient increased gradually. Considering the inappropriate increase of the pacing threshold, we decided to reposition the right ventricular (RV) lead with good sensing and threshold parameters confirmed. Subsequent 22 months interrogation follow-up revealed a stable lead position and electrical specifications. Furthermore, antiarrhythmic drugs were maximally increased, while ATP burst was remarkably decreased and the inappropriate ICD shock never occurred until now. An inappropriate pacing threshold was increased secondary to repeated ICD electrical storm. A timely active lead position adjustment reduced the pacing threshold and eliminated the risk of premature battery depletion.
Prevalence of Pulsatile Tinnitus Among Patients With Migraine.
Weinreich, Heather M; Carey, John P
2016-03-01
To examine the prevalence of pulsatile tinnitus (PT) among patients with a diagnosis of migraine and to determine if treatment of migraine improves symptoms. Single-institution retrospective patient review. Academic tertiary referral center. Billing data capturing ICD-9 codes 346.xx and 388.3x was used to identify patients with history of migraine and tinnitus. Patients were excluded if the symptom of PT could be attributed to an alternate diagnosis. Data were extracted from the patients' electronic medical records. Therapeutic patients were prescribed a strict migraine diet with or without migraine medication. Subjective improvement in tinnitus as documented in electronic medical records. One thousand two hundred four patients were identified with an ICD-9 code for migraine and of those patients, 12% (n = 145) had an ICD-9 code for tinnitus. After ruling out alternative causes, the prevalence of PT among all patients with migraine was 1.9%. Of migrainers with PT who underwent migraine treatment, 11 out of 16 reported resolution or improvement of their PT. PT can be observed in the context of migraine. Migraine treatment with avoidance of dietary triggers with or without medication can possibly lead to resolution of PT.
Safak, Erdal; Schmitz, Dietmar; Konorza, Thomas; Wende, Christian; De Ros, Jose Olague; Schirdewan, Alexander
2013-08-01
The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional. The studied active-fixation, steroid-eluting lead (Linox(smart) S DX, BIOTRONIK SE & Co KG, Berlin, Germany) is one French thinner than its predecessor and coated with lubricious SilGlide to improve lead handling. A dedicated ICD device has a self-adaptive atrial input stage including a fourfold amplifier. The amplification, filtering, and adapted atrial input stage are located in the Lumax 540 VR-T DX (BIOTRONIK). The Linox(smart) S DX ICD lead delivers only the signal. The lead was evaluated during implantation; at predischarge; and 1-, 3-, and 6-month follow-up examinations. The primary endpoint (efficacy) was the rate of appropriate atrial sensing tests. The secondary endpoint (safety) was freedom from lead-related invasive reinterventions. Both safety and efficacy were expected to be significantly higher than 90%. The study enrolled 116 patients at 25 clinical sites. Skin-to-skin operation time was 52.4 ± 26.2 minutes. The investigators graded lead insertion as "easy" in 87% of patients. Mean P-wave amplitudes (preamplified) varied from 5.0 to 6.1 mV in different body positions. Both primary and secondary endpoints were met, as 93.8% (364/388; P = 0.005) of specific sensing tests indicated appropriate atrial sensing, and 94.8% (110/116; P = 0.048) of patients were free from reinterventions (lead dislodgement). Analysis of arrhythmia episodes stored in ICDs and elective 24-hour Holter electrocardiogram tests raised no concerns about lead functionality. The studied ICD lead with a floating atrial sensing dipole met the predefined safety expectation and demonstrated appropriate atrial sensing performance. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.
Cardiac Implantable Electronic Device-Related Infection and Extraction Trends in the U.S.
Sridhar, Arun Raghav Mahankali; Lavu, Madhav; Yarlagadda, Vivek; Reddy, Madhu; Gunda, Sampath; Afzal, Rizwan; Atkins, Donita; Gopinathanair, Rakesh; Dawn, Buddhadeb; Lakkireddy, Dhanunjaya R
2017-03-01
Implantation of cardiac implanted electronic device (CIED) has surged lately. This resulted in a rise in cardiac device-related infections (CDI) and inevitably, lead extractions. We examined the recent national trend in the incidence of CIED infections and lead extractions in hospitalized patients and associated mortality. Using the Nationwide Inpatient Sample for the years 2003-2011 we identified patients diagnosed with a CDI-associated infection as determined by discharge ICD-9 diagnostic codes. We examined the trend of device-related infections overall and in different subgroups. We studied mortality associated with device infections, lead extractions, associated costs, and length of stay. There is a significant increase in the number of hospitalizations due to CDI from 5,308 in the year 2003 to 9,948 in 2011. Males (68%), Caucasians (77%), and age group 65-84 years (56.4%) accounted for majority of CDI. The mortality associated with CDI was 4.5 %, and was worse in higher age groups (2.5% in 18-44 years compared to 5.3% in 85+ years, P < 0.001). Average length of stay was unchanged over the years remaining at 13.6 days; however, mean hospitalization charges increased from $91,348 in 2003 to $173,211 in 2011 (P < 0.001). Among all lead extraction procedures, the percentage of patients undergoing lead extraction secondary to CDI also increased from 2003 (59.1%) to 2011 (76.7%), P-value < 0.001. Healthcare burden associated with CDI infections and associated lead extractions has significantly increased in the recent years. Despite an increase in cost associated with CIED infections, mortality remains the same, and is higher in older patients. © 2017 Wiley Periodicals, Inc.
Koneru, Jayanthi N; Swerdlow, Charles D; Ploux, Sylvain; Sharma, Parikshit S; Kaszala, Karoly; Tan, Alex Y; Huizar, Jose F; Vijayaraman, Pugazhendi; Kenigsberg, David; Ellenbogen, Kenneth A
2017-02-01
Implantable cardioverter defibrillators (ICDs) must establish a balance between delivering appropriate shocks for ventricular tachyarrhythmias and withholding inappropriate shocks for lead-related oversensing ("noise"). To improve the specificity of ICD therapy, manufacturers have developed proprietary algorithms that detect lead noise. The SecureSense TM RV Lead Noise discrimination (St. Jude Medical, St. Paul, MN, USA) algorithm is designed to differentiate oversensing due to lead failure from ventricular tachyarrhythmias and withhold therapies in the presence of sustained lead-related oversensing. We report 5 patients in whom appropriate ICD therapy was withheld due to the operation of the SecureSense algorithm and explain the mechanism for inhibition of therapy in each case. Limitations of algorithms designed to increase ICD therapy specificity, especially for the SecureSense algorithm, are analyzed. The SecureSense algorithm can withhold appropriate therapies for ventricular arrhythmias due to design and programming limitations. Electrophysiologists should have a thorough understanding of the SecureSense algorithm before routinely programming it and understand the implications for ventricular arrhythmia misclassification. © 2016 Wiley Periodicals, Inc.
Inappropriate ICD discharges due to "triple counting" during normal sinus rhythm.
Khan, Ejaz; Voudouris, Apostolos; Shorofsky, Stephen R; Peters, Robert W
2006-11-01
To describe the clinical course of a patient with multiple ICD shocks in the setting of advanced renal failure and hyperkalemia. The patient was brought to the Electrophysiology Laboratory where the ICD was interrogated. The patient was found to be hyperkalemic (serum potassium 7.6 mg/dl). Analysis of stored intracardiac electrograms from the ICD revealed "triple counting" (twice during his QRS complex and once during the T wave) and multiple inappropriate shocks. Correction of his electrolyte abnormality normalized his electrogram and no further ICD activations were observed. Electrolyte abnormalities can distort the intracardiac electrogram in patients with ICD's and these changes can lead to multiple inappropriate shocks.
Koneru, Jayanthi N; Jones, Paul W; Hammill, Eric F; Wold, Nicholas; Ellenbogen, Kenneth A
2018-05-10
The transvenous implantable cardioverter-defibrillator (ICD) lead is the most common source of complications in a traditional ICD system. This investigation aims to determine the incidence, predictors, and costs associated with these complications using a large insurance database. Data from the OptumLabs™ Data Warehouse, which include diagnosis, physician and procedure codes, and claims from patient hospitalizations, were analyzed. Patients with a de novo ICD or cardiac resynchronization therapy defibrillator implanted from January 1, 2003, through June 30, 2015, were included; those who did not have continuous coverage beginning 1 year before implantation were excluded, resulting in 40 837 patients followed up over an average of 2.3±2.1 years. Patients were followed up until they had the procedure or their last active date in the database. Of 20 580 device procedures, 2165 (5.3%) and 771 (1.9%) had mechanical and infectious complications, respectively. The 5-year rate of freedom from mechanical complication was 92.0% and 89.3% for ICDs and cardiac resynchronization therapy defibrillators, respectively. Infectious complications were more likely in patients with a history of atrial fibrillation, diabetes mellitus, and renal disease, and the risk increased with subsequent device procedures. Younger age, female sex, lack of comorbidities, and implantations between 2003 and 2008 were associated with more mechanical complications. Incidence of mechanical and infectious complications of transvenous ICD leads over long-term follow-up is much higher in the real world than in clinical studies. In our study cohort, 1 of 4 transvenous ICD leads had mechanical complications when followed up to 10 years. The high rate of reintervention leads to additional complications. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Sasaki, Shingo; Tomita, Hirofumi; Tsurugi, Takuo; Ishida, Yuji; Shoji, Yoshihiro; Nishizaki, Kimitaka; Kinjo, Takahiko; Endo, Tomohide; Nishizaki, Fumie; Hanada, Kenji; Sasaki, Kenichi; Horiuchi, Daisuke; Kimura, Masaomi; Higuma, Takumi; Okamatsu, Hideharu; Tanaka, Yasuaki; Koyama, Junjiroh; Okumura, Ken
2018-04-11
The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced as a new alternative to conventional transvenous ICD (TV-ICD) in Japan in February 2016, but its safety and efficacy are unclear.Methods and Results:A total of 60 patients (48 men, median age, 60 years; IQR, 44-67 years; primary prevention, n=24) underwent S-ICD implantation between February 2016 and August 2017. The device pocket was formed in the intermuscular space between the serratus anterior muscle and the latissimus dorsi muscle, and the parasternal S-ICD lead was placed according to pre-implant screening. Defibrillation test was performed in 56 patients (93%). Ventricular fibrillation (VF) was induced in 55 patients and terminated by a single 65-J shock in all patients. The median time to shock therapy was 13.4 s (IQR, 12.1-14.9 s) and the median post-shock impedance of the S-ICD lead was 64 Ω (IQR, 58-77 Ω). There were no operation-related complications or subsequent infectious complications. During follow-up (median, 275 days; IQR, 107-421 days), 1 patient (1.7%) had appropriate shock for VF with successful termination, whereas 5 patients (8.3%) had inappropriate shock due to oversensing of myopotential (n=3) or T-wave (n=1), and detection of supraventricular tachycardia (n=1). S-ICD is a safe and effective alternative to conventional TV-ICD. The long-term safety and efficacy of the S-ICD need further investigation.
Clark, Bradley C; Davis, Tanya D; El-Sayed Ahmed, Magdy M; McCarter, Robert; Ishibashi, Nobuyuki; Jordan, Christopher P; Kane, Timothy D; Kim, Peter C W; Krieger, Axel; Nath, Dilip S; Opfermann, Justin D; Berul, Charles I
2016-05-01
Epicardial implantable cardioverter-defibrillator (ICD) placement in infants, children, and patients with complex cardiac anatomy requires an open surgical thoracotomy and is associated with increased pain, longer length of stay, and higher cost. The purpose of this study was to compare an open surgical epicardial placement approach with percutaneous pericardial placement of an ICD lead system in an infant piglet model. Animals underwent either epicardial placement by direct suture fixation through a left thoracotomy or minimally invasive pericardial placement with thoracoscopic visualization. Initial lead testing and defibrillation threshold testing (DFT) were performed. After the 2-week survival period, repeat lead testing and DFT were performed before euthanasia. Minimally invasive placement was performed in 8 piglets and open surgical placement in 7 piglets without procedural morbidity or mortality. The mean initial DFT value was 10.5 J (range 3-28 J) in the minimally invasive group and 10.0 J (range 5-35 J) in the open surgical group (P = .90). After the survival period, the mean DFT value was 12.0 J (range 3-20 J) in the minimally invasive group and 12.3 J (range 3-35 J) in the open surgical group (P = .95). All lead and shock impedances, R-wave amplitudes, and ventricular pacing thresholds remained stable throughout the survival period. Compared with open surgical epicardial ICD lead placement, minimally invasive pericardial placement demonstrates an equivalent ability to effectively defibrillate the heart and has demonstrated similar lead stability. With continued technical development and operator experience, the minimally invasive method may provide a viable alternative to epicardial ICD lead placement in infants, children, and adults at risk of sudden cardiac death. Copyright © 2016 Heart Rhythm Society. All rights reserved.
Okamura, Hideo; Friedman, Paul A; Inoue, Yuko; Noda, Takashi; Aiba, Takeshi; Yasuda, Satoshi; Ogawa, Hisao; Kamakura, Shiro; Kusano, Kengo; Espinosa, Raul E
2016-09-23
Single-coil defibrillator leads have gained favor because of their potential ease of extraction. However, a high defibrillation threshold remains a concern in patients with hypertrophic cardiomyopathy (HCM), and in many cases, dual-coil leads have been used for this patient group. There is little data on using single-coil leads for HCM patients. We evaluated 20 patients with HCM who received an implantable cardioverter-defibrillator (ICD) on the left side in combination with a dual-coil lead. Two sets of defibrillation tests were performed in each patient, one with the superior vena cava (SVC) coil "on" and one with the SVC coil "off". ICDs were programmed to deliver 25 joules (J) for the first attempt followed by maximum energy (35 J or 40 J). Shock impedance and shock pulse width at 25 J in each setting as well as the results of the shock were analyzed. All 25-J shocks in both settings successfully terminated ventricular fibrillation. However, shock impedance and pulse width increased substantially with the SVC coil programmed "off" compared with "on" (66.4±6.1 ohm and 14.0±1.3 ms "off" vs. 41.9±5.0 ohm and 9.3±0.8 ms "on", P<0.0001 respectively). Biphasic 25-J shocks with the SVC coil 'off' successfully terminated ventricular fibrillation in HCM patients, indicating a satisfactory safety margin for 35-J devices. Single-coil leads appear appropriate for left-sided implantation in this patient group. (Circ J 2016; 80: 2199-2203).
Ptaszyński, Paweł; Grabowski, Marcin; Kowalski, Oskar; Kempa, Maciej; Mitkowski, Przemysław; Przybylski, Andrzej; Sterliński, Maciej
2017-01-01
In the past years, cardiovascular mortality has decreased but despite these cardiovascular diseases are responsible for millions of deaths every year in the world and approximately 25% of which are sudden cardiac death (SCD). Implantable defibrillators (ICD) is proven therapy used in primary and secondary SCD prevention. Currently majority of devices use transvenous leads inserted predominantly into the right heart for both pacing and defibrillation. On the other hand, ICD may cause complica-tions, including inappropriate shocks, device-related infection and lead failure. Problems with transvenous leads prompted the development of a subcutaneous defibrillator (S-ICD) with an electrode system that is placed entirely subcutaneously, outside the thoracic cavity. The device may be useful when venous access is difficult, in young patients and in patients at particular risk of infection. S-ICD is not suitable for patients with indications for bradycardia pacing, cardiac resynchronisation therapy and in cases with tachyarrhythmia easily terminated by antitachycardia pacing.
Inadvertent transarterial insertion of atrial and ventricular defibrillator leads.
Issa, Ziad F; Rumman, Syeda S; Mullin, James C
2009-01-01
Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle (LV) is a rare but well-recognized complication of device implantation [1]. We report a case of inadvertent transarterial implantation of dual-chamber ICD leads; the ventricular lead positioned in the LV and the atrial lead positioned in the aortic root. The tip of the atrial lead migrated across the aortic wall and captured the epicardial surface of the left atrium. The diagnosis was made 5 years after the implantation procedure with no apparent adverse events directly related to left heart lead placement.
Kaspar, Mathias; Fette, Georg; Güder, Gülmisal; Seidlmayer, Lea; Ertl, Maximilian; Dietrich, Georg; Greger, Helmut; Puppe, Frank; Störk, Stefan
2018-04-17
Heart failure is the predominant cause of hospitalization and amongst the leading causes of death in Germany. However, accurate estimates of prevalence and incidence are lacking. Reported figures originating from different information sources are compromised by factors like economic reasons or documentation quality. We implemented a clinical data warehouse that integrates various information sources (structured parameters, plain text, data extracted by natural language processing) and enables reliable approximations to the real number of heart failure patients. Performance of ICD-based diagnosis in detecting heart failure was compared across the years 2000-2015 with (a) advanced definitions based on algorithms that integrate various sources of the hospital information system, and (b) a physician-based reference standard. Applying these methods for detecting heart failure in inpatients revealed that relying on ICD codes resulted in a marked underestimation of the true prevalence of heart failure, ranging from 44% in the validation dataset to 55% (single year) and 31% (all years) in the overall analysis. Percentages changed over the years, indicating secular changes in coding practice and efficiency. Performance was markedly improved using search and permutation algorithms from the initial expert-specified query (F1 score of 81%) to the computer-optimized query (F1 score of 86%) or, alternatively, optimizing precision or sensitivity depending on the search objective. Estimating prevalence of heart failure using ICD codes as the sole data source yielded unreliable results. Diagnostic accuracy was markedly improved using dedicated search algorithms. Our approach may be transferred to other hospital information systems.
Lewis, Krystina B; Stacey, Dawn; Carroll, Sandra L; Boland, Laura; Sikora, Lindsey; Birnie, David
2016-07-01
Every 4-7 years an implantable cardioverter defibrillator (ICD) pulse generator must be replaced surgically. This procedure is not without risk. In some cases, the risk versus benefit ratio may be against replacement. We aimed to synthesize the evidence on risks, benefits, and costs related to ICD replacement. A systematic review was conducted using electronic databases from 2000 onward. Literature screening, quality appraisal, and data extraction were independently conducted by two reviewers. Outcomes included major and minor complications, ICD therapies, and costs, which were synthesized descriptively. Of 1,483 citations, 17 nonrandomized studies met criteria. Median rate of major complications was 4.05% (range 0.55-7.37%) and minor complications was 3.50% (range 0.36-7.37%). Without non-ICD control groups, the true risk reduction provided by the ICD following replacement is unknown. Following ICD replacement, annualized rate of appropriate ICD therapy was 10.52% (range 2.42-75.00%). Of these, patients without therapies during their first generator life and those no longer meeting ICD criteria received appropriate therapies at nontrivial rates. Rates of complications associated with ICD replacement are substantial. No study had nonreplacement groups, hence the true risk reduction provided by the ICD following replacement is unknown. Our analysis did not identify a subgroup at low risk of therapies following replacement. Shared discussions should occur with patients about the evidence, healthcare goals, risk tolerances, and feelings about life and death trade-offs to enable high-quality decisions about ICD replacement. ©2016 Wiley Periodicals, Inc.
Subcutaneous chronic implantable defibrillation systems in humans.
Cappato, Riccardo; Smith, Warren M; Hood, Margaret A; Crozier, Ian G; Jordaens, Luc; Spitzer, Stefan G; Ardashev, Andrey V; Boersma, Lucas; Lupo, Pierpaolo; Grace, Andrew A; Bardy, Gust H
2012-09-01
The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements. For this purpose, 4 S-ICD configurations were tested in 78 patients at the time of transvenous (TV)-ICD implantation. The optimal configuration was tested in 49 more patients to comparatively assess the subcutaneous defibrillation threshold (S-DFT) versus the standard TV-ICD. Long-term implants were evaluated in 55 patients using an implanted system (chronic human study). The acute humans studies led to an optimal S-ICD configuration comprising a parasternal electrode and left anterolateral thoracic pulse generator. Both configurations successfully terminated 98% of induced ventricular fibrillation (VF), but significantly higher energy levels were required with S-ICD than with TV-ICD systems (36.6 ± 19.8 J vs. 11.1 ± 8.5 J). In the chronic study, all 137 VF episodes induced at time of implant were detected with a 98% conversion rate. Two pocket infections and four lead revisions were required during 10 ± 1 months of follow-up. During this period, survival was 98%, and 12 spontaneous ventricular tachyarrhythmias were detected and treated by the device. These data show that the S-ICD systems here consistently detected and converted VF induced at time of implant as well as sustained ventricular tachyarrhythmias occurring during follow-up (248).
Pre-discharge defibrillation testing: Is it still justified?
Kempa, Maciej; Królak, Tomasz; Drelich, Łukasz; Budrejko, Szymon; Daniłowicz-Szymanowicz, Ludmiła; Lewicka, Ewa; Kozłowski, Dariusz; Raczak, Grzegorz
2016-01-01
An implantable cardioverter-defibrillator (ICD) is routinely used to prevent sudden cardiac death. Since the introduction of that device into clinical practice, a defibrillation test (the so-called pre-discharge test [PDT]) has been an inseparable part of the ICD implantation procedure. Recently, the usefulness of PDT has been called into question. The aim of this research was to analyze ICD tests performed within two time periods: in years 1995-2001 (period I) and 2007-2010 (period II), in order to compare the results of tests and solutions to all the problems with ICD systems revealed by means of PDT. During period I, 193 tests were performed, among which the ICD system malfunction was observed in 16 cases. Those included: sensing issues, specifically R-wave undersensing during ventricular fibrillation (VF) (7 patients) and T-wave oversensing (4 patients), as well as high defibrillation threshold (DFT) (2 patients) and ICD-pacemaker interaction (3 patients). During period II, among 561 tests, system malfunction was observed in 15 cases. In 1 patient it was VF undersensing, and in the remaining 14 it was high DFT. All the above problems were solved by means of appropriate ICD reprogramming, repositioning of the endocardial defibrillation lead or implantation of an additional subcutaneous defibrillation lead. Contemporary ICD technical solutions, compared to older systems, in most cases allow to avoid sensing problems. The key rationale behind ICD testing is the ability to confirm the efficacy of high-voltage therapy. Despite the increasing maximal defibrillation out-put of devices, and all possible adjustments to the characteristics of the impulse, there is still a group of patients that require additional procedures to ensure the appropriate defibrillation efficacy.
A model for indexing medical documents combining statistical and symbolic knowledge.
Avillach, Paul; Joubert, Michel; Fieschi, Marius
2007-10-11
To develop and evaluate an information processing method based on terminologies, in order to index medical documents in any given documentary context. We designed a model using both symbolic general knowledge extracted from the Unified Medical Language System (UMLS) and statistical knowledge extracted from a domain of application. Using statistical knowledge allowed us to contextualize the general knowledge for every particular situation. For each document studied, the extracted terms are ranked to highlight the most significant ones. The model was tested on a set of 17,079 French standardized discharge summaries (SDSs). The most important ICD-10 term of each SDS was ranked 1st or 2nd by the method in nearly 90% of the cases. The use of several terminologies leads to more precise indexing. The improvement achieved in the models implementation performances as a result of using semantic relationships is encouraging.
A Model for Indexing Medical Documents Combining Statistical and Symbolic Knowledge.
Avillach, Paul; Joubert, Michel; Fieschi, Marius
2007-01-01
OBJECTIVES: To develop and evaluate an information processing method based on terminologies, in order to index medical documents in any given documentary context. METHODS: We designed a model using both symbolic general knowledge extracted from the Unified Medical Language System (UMLS) and statistical knowledge extracted from a domain of application. Using statistical knowledge allowed us to contextualize the general knowledge for every particular situation. For each document studied, the extracted terms are ranked to highlight the most significant ones. The model was tested on a set of 17,079 French standardized discharge summaries (SDSs). RESULTS: The most important ICD-10 term of each SDS was ranked 1st or 2nd by the method in nearly 90% of the cases. CONCLUSIONS: The use of several terminologies leads to more precise indexing. The improvement achieved in the model’s implementation performances as a result of using semantic relationships is encouraging. PMID:18693792
ICD defibrillation failure solved in an unusual fashion.
Oliveira, Ricardo Gil; Madeira, Francisco; Ferreira, Ana Rita; Antunes, Susana; Morais, Carlos; Gil, Victor
2010-04-01
An implantable cardioverter defibrillator (ICD) is designed to sense life-threatening ventricular arrhythmias and terminate them, either by rapid pacing or by delivering an electrical shock. Nowadays it is a proven therapy for both primary and secondary prevention of sudden cardiac death. The typical configuration of an ICD consists of a right ventricular sensing/defibrillator lead with two coils (one distal, located in the right ventricle, and one proximal, located at the superior vena cava-right atrium junction) and an active can, the so-called "ventricular triad". Although effective in the vast majority of patients, it could be argued that this is not the most rational arrangement in electrical terms, since the main shock vector is anteriorly displaced in relation to the greater portion of the left ventricular mass. We describe a case of an ICD defibrillation failure that was solved by placing an additional defibrillator lead in a tributary of the coronary sinus.
Chronic lymphocytic leukemia skin infiltration mimicking an ICD pocket infection: a case report.
Snorek, M; Bulava, A; Vonke, I
2017-03-24
We are presenting a case report on an unreported and unusual cutaneous manifestation of chronic lymphocytic leukemia in a patient with an implantable cardioverter-defibrillator (ICD). A 65-year-old man with a history of chronic lymphocytic leukemia (CLL), previously treated with chlorambucil, was referred in October 2013 for extraction of a single chamber ICD due to a suspected device-related infection in the pulse generator area (left-hand side of Fig. 1). The ICD system (Current VR, St. Jude Medical, USA) had been implanted in November 2009. The patient complained of painless erythema with pruritus in the pocket area. Inflammatory blood parameters were C-reactive protein 17.3 mg/L and leucocytes 29.0 × 10 9 /L. Due to the atypical appearance of the pocket area we did not extract the device. Instead, we created an exploratory excision in the skin induration, which had been present for approximately 6 weeks, and conducted a microbiological and histological examination. All cultivation examinations were negative. However, we did histologically show skin infiltration by CD-5 positive low-grade B-cell chronic lymphocytic leukemia/small lymphocytic lymphoma (B-CLL/SLL). Re-initiation of chemotherapy was not necessary and the skin induration completely disappeared within 2 months (right-hand side of Fig. 1). Complete removal of an ICD system carries considerable risk. In patients with a history of hematological disease, it is crucial to exclude cutaneous manifestations of the disease prior to device removal.
Development of the ICD-10 simplified version and field test.
Paoin, Wansa; Yuenyongsuwan, Maliwan; Yokobori, Yukiko; Endo, Hiroyoshi; Kim, Sukil
2018-05-01
The International Statistical Classification of Diseases and Related Health Problems, 10th Revision (ICD-10) has been used in various Asia-Pacific countries for more than 20 years. Although ICD-10 is a powerful tool, clinical coding processes are complex; therefore, many developing countries have not been able to implement ICD-10-based health statistics (WHO-FIC APN, 2007). This study aimed to simplify ICD-10 clinical coding processes, to modify index terms to facilitate computer searching and to provide a simplified version of ICD-10 for use in developing countries. The World Health Organization Family of International Classifications Asia-Pacific Network (APN) developed a simplified version of the ICD-10 and conducted field testing in Cambodia during February and March 2016. Ten hospitals were selected to participate. Each hospital sent a team to join a training workshop before using the ICD-10 simplified version to code 100 cases. All hospitals subsequently sent their coded records to the researchers. Overall, there were 1038 coded records with a total of 1099 ICD clinical codes assigned. The average accuracy rate was calculated as 80.71% (66.67-93.41%). Three types of clinical coding errors were found. These related to errors relating to the coder (14.56%), those resulting from the physician documentation (1.27%) and those considered system errors (3.46%). The field trial results demonstrated that the APN ICD-10 simplified version is feasible for implementation as an effective tool to implement ICD-10 clinical coding for hospitals. Developing countries may consider adopting the APN ICD-10 simplified version for ICD-10 code assignment in hospitals and health care centres. The simplified version can be viewed as an introductory tool which leads to the implementation of the full ICD-10 and may support subsequent ICD-11 adoption.
Optimal programming management of ventricular tachycardia storm in ICD patients
Qian, Zhiyong; Guo, Jianghong; Zhang, Zhiyong; Wang, Yao; Hou, Xiaofeng; Zou, Jiangang
2015-01-01
Abstract Ventricular tachycardia storm (VTS) is defined as a life-threatening syndrome of three or more separate episodes of ventricular tachycardia (VT) leading to implantable cardioverter defibrillator (ICD) therapy within 24 hours. Patients with VTS have poor outcomes and require immediate medical attention. ICD shocks have been shown to be associated with increased mortality in several studies. Optimal programming in minimization of ICD shocks may decrease mortality. Large controlled trials showed that long detection time and high heart rate detection threshold reduced ICD shock burden without an increase in syncope or death. As a fundamental therapy of ICD, antitachycardia pacing (ATP) can terminate most slow VT with a low risk of acceleration. For fast VT, burst pacing is more effective and less likely to result in acceleration than ramp pacing. One algorithm of optimal programming management during a VTS is presented in the review. PMID:25745473
The utility of an automated electronic system to monitor and audit transfusion practice.
Grey, D E; Smith, V; Villanueva, G; Richards, B; Augustson, B; Erber, W N
2006-05-01
Transfusion laboratories with transfusion committees have a responsibility to monitor transfusion practice and generate improvements in clinical decision-making and red cell usage. However, this can be problematic and expensive because data cannot be readily extracted from most laboratory information systems. To overcome this problem, we developed and introduced a system to electronically extract and collate extensive amounts of data from two laboratory information systems and to link it with ICD10 clinical codes in a new database using standard information technology. Three data files were generated from two laboratory information systems, ULTRA (version 3.2) and TM, using standard information technology scripts. These were patient pre- and post-transfusion haemoglobin, blood group and antibody screen, and cross match and transfusion data. These data together with ICD10 codes for surgical cases were imported into an MS ACCESS database and linked by means of a unique laboratory number. Queries were then run to extract the relevant information and processed in Microsoft Excel for graphical presentation. We assessed the utility of this data extraction system to audit transfusion practice in a 600-bed adult tertiary hospital over an 18-month period. A total of 52 MB of data were extracted from the two laboratory information systems for the 18-month period and together with 2.0 MB theatre ICD10 data enabled case-specific transfusion information to be generated. The audit evaluated 15,992 blood group and antibody screens, 25,344 cross-matched red cell units and 15,455 transfused red cell units. Data evaluated included cross-matched to transfusion ratios and pre- and post-transfusion haemoglobin levels for a range of clinical diagnoses. Data showed significant differences between clinical units and by ICD10 code. This method to electronically extract large amounts of data and linkage with clinical databases has provided a powerful and sustainable tool for monitoring transfusion practice. It has been successfully used to identify areas requiring education, training and clinical guidance and allows for comparison with national haemoglobin-based transfusion guidelines.
Garg, Jalaj; Chaudhary, Rahul; Shah, Neeraj; Palaniswamy, Chandrasekar; Bozorgnia, Babak; Nazir, Talha; Natale, Andrea; Kutyifa, Valentina
We aimed to study the effect of right ventricular implantable cardioverter defibrillator (ICD) lead positioning on clinical outcomes in patients undergoing ICD placement. A systematic literature search was performed using PubMed, EMBASE, Web of Science, and Cochrane Central Register of Controlled Trials to identify clinical trials comparing outcomes in patients with ICD leads in apical and non-apical positions. The primary outcome of our study was death at 1-year follow-up. Secondary outcomes studied were "death at 3years", "total number of shocks", "appropriate shocks", "inappropriate shocks" and "cut-to-suture time". We analyzed a total of 3731 patients (2852 in apical and 879 in non-apical ICD groups) enrolled in 4 clinical trials. No significant difference was observed between the apical and non-apical ICD groups in all-cause mortality at 1year (OR 0.88; 95% CI 0.51-1.49, p=0.63; I 2 =5.32%). Similarly, no differences were seen between the two groups in death at 3years (OR=0.76; 95% CI 0.56-1.04, p=0.08; I 2 =0%), total number of shocks (OR 0.99; 95% CI 0.81-1.22, p=0.95; I 2 =0%), appropriate shocks (OR 1.00; 95% CI 0.79-1.27, p=0.99; I 2 =0%), inappropriate shocks (OR 0.98; 95% CI 0.70-1.37, p=0.91; I 2 =0%) and cut-to-suture time (Standard mean difference=-0.03; 95% CI -0.20 to 0.14, p=0.73; I 2 =0%). No publication bias was seen. Non-apical RV ICD lead implantation is non-inferior to traditional RV apical position with no significant differences in mortality, total number of shocks, appropriate shocks, inappropriate shocks and procedural time. Copyright © 2017 Elsevier Inc. All rights reserved.
T-wave loop area from a pre-implant 12-lead ECG is associated with appropriate ICD shocks
Hnatkova, Katerina; Friede, Tim; Malik, Marek; Zabel, Markus
2017-01-01
Aims In implantable cardioverter-defibrillator (ICD) patients, predictors of ICD shocks and mortality are needed to improve patient selection. Electrocardiographic (ECG) markers are simple to obtain and have been demonstrated to predict mortality. We aimed to assess the association of T-wave loop area and circularity with ICD shocks. Methods The study investigated patients with ICDs implanted between 1998 and 2010 for whom digital 12-lead ECGs (Schiller CS200 ECG-Network) of sufficient quality were obtained within 1 month prior to the implantation. T-wave loop area and circularity were calculated. Follow-up data of appropriate shocks were obtained during ICD clinic visits that included reviews of device stored electrograms. Results A total of 605 patients (82% males) were included; 68% had ischemic cardiomyopathy and 72% were treated for primary prevention. Over 3.8±1.4 years of follow-up, 114 patients (19%) experienced appropriate shock(s). Those with smaller T-wave loop area received fewer shocks (TLA, hazard ratio, HR, per increase of 1 technical unit, 0.71; [95% confidence interval, 0.53–0.94]; P = 0.02) and those with larger T-wave loop circularity (TLC) representing rounder T wave loop received more shocks (HR per 1% TLC increase 2.96; [0.85–10.36]; P = 0.09). When the quartile containing the largest TLA and TLC values, respectively, were compared to the remaining cases, TLA remained significantly associated with fewer and TLC with more frequent shocks also after multivariate adjustment for clinical variables (HR, 0.59 [0.35–0.99], P = 0.044; and 1.64 [1.08–2.49], P = 0.021, respectively). Conclusions The size and shape of the T-wave loop calculated from pre-implantation 12-lead ECGs are associated with appropriate ICD shocks. PMID:28291831
Green, Ariel R; Boyd, Cynthia M; Rickard, John; Gomon, Robert; Leff, Bruce
2015-12-23
In elderly heart failure patients, the survival benefit of implantable cardioverter-defibrillators (ICDs) may be attenuated due to competing health risks, and the risk of adverse outcomes magnified. Our objective was to examine older adults' attitudes towards ICD implantation in the context of competing health risks, exploring the determinants of ICD decision-making among a group of patients who had faced the decision in the past. Telephone survey with a qualitative component. Patients were age ≥70 with single- or dual-chamber ICDs from a single academic cardiac device clinic. Health status was assessed with the Vulnerable Elders Survey (VES-13). Responses to open-ended questions were transcribed verbatim; an "editing analysis" approach was used to extract themes. Forty-four ICD recipients participated (mean age 77.5 years). Nineteen participants (43%) had VES-13 scores ≥3, indicating a 50% likelihood of death or functional decline within 2 years. Twenty-one participants (48%) had received prior ICD shocks. Forty participants (91%) said they would "definitely" choose to get an ICD again in their current health. By and large, patients revealed a strong desire to extend life, expressed complete confidence in the lifesaving capabilities of their ICDs, and did not describe consideration of competing health risks. In this pilot telephone survey with a qualitative component, nearly all older adults with ICDs would still choose to get an ICD despite high short-term risk of death or health deterioration. These findings suggest the need to partner more effectively with patients and families to decide how best to use medical technologies, particularly for older adults with competing risks.
Pacemakers and implantable cardioverter-defibrillators in pediatric patients.
Silka, Michael J; Bar-Cohen, Yaniv
2006-11-01
The use of pacemakers and implantable cardioverter-defibrillators (ICDs) in infants, children, and patients with congenital heart disease presents unique challenges and considerations. They include uncommon indications for device implantation, innovative approaches to lead implantation and configuration, and age-dependent and disease-specific aspects of device programming. In this review, the current indications for pacemaker and ICD implantation in young patients are discussed, followed by consideration of the approaches to lead and device placement in very small patients and those with complex congenital heart disease, in whom unique problems may be encountered. The limitations of programmability of current pacemakers and ICDs when used in young patients are discussed, followed by an analysis of long-term device follow-up and potential late complications.
Kersten, Daniel J; Yi, Jinju; Feldman, Alyssa M; Brahmbhatt, Kunal; Asheld, Wilbur J; Germano, Joseph; Islam, Shahidul; Cohen, Todd J
2016-12-01
The purpose of this study was to determine if implantation of multiple recalled defibrillator leads is associated with an increased risk of lead failure. The authors of the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS") have previously reported a relationship between recalled lead status, lead failure, and patient mortality. This substudy analyzes the relationship in a smaller subset of patients who received more than one recalled lead. The specific effects of having one or more recalled leads have not been previously examined. This study analyzed lead failure and mortality of 3802 patients in PAIDLESS and compared outcomes with respect to the number of recalled leads received. PAIDLESS includes all patients at Winthrop University Hospital who underwent defibrillator lead implantation between February 1, 1996 and December 31, 2011. Patients with no recalled ICD leads, one recalled ICD lead, and two recalled ICD leads were compared using the Kaplan-Meier method and log-rank test. Sidak adjustment method was used to correct for multiple comparisons. All calculations were performed using SAS 9.4. P-values <.05 were considered statistically significant. This study included 4078 total ICD leads implanted during the trial period. There were 2400 leads (59%) in the no recalled leads category, 1620 leads (40%) in the one recalled lead category, and 58 leads (1%) in the two recalled leads category. No patient received more than two recalled leads. Of the leads categorized in the two recalled leads group, 12 experienced lead failures (21%), which was significantly higher (P<.001) than in the no recalled leads group (60 failures, 2.5%) and one recalled lead group (81 failures; 5%). Multivariable Cox's regression analysis found a total of six significant predictive variables for lead failure including the number of recalled leads (P<.001 for one and two recalled leads group). The number of recalled leads is highly predictive of lead failure. Lead-based multivariable Cox's regression analysis produced a total of six predictive variable categories for lead failure, one of which was the number of recalled leads. Kaplan-Meier analysis showed that the leads in the two recalled leads category failed faster than both the no recalled lead and one recalled lead groups. The greater the number of recalled leads to which patients are exposed, the greater the risk of lead failure.
Rantner, Lukas J; Vadakkumpadan, Fijoy; Spevak, Philip J; Crosson, Jane E; Trayanova, Natalia A
2013-01-01
There is currently no reliable way of predicting the optimal implantable cardioverter-defibrillator (ICD) placement in paediatric and congenital heart defect (CHD) patients. This study aimed to: (1) develop a new image processing pipeline for constructing patient-specific heart–torso models from clinical magnetic resonance images (MRIs); (2) use the pipeline to determine the optimal ICD configuration in a paediatric tricuspid valve atresia patient; (3) establish whether the widely used criterion of shock-induced extracellular potential (Φe) gradients ≥5 V cm−1 in ≥95% of ventricular volume predicts defibrillation success. A biophysically detailed heart–torso model was generated from patient MRIs. Because transvenous access was impossible, three subcutaneous and three epicardial lead placement sites were identified along with five ICD scan locations. Ventricular fibrillation was induced, and defibrillation shocks were applied from 11 ICD configurations to determine defibrillation thresholds (DFTs). Two configurations with epicardial leads resulted in the lowest DFTs overall and were thus considered optimal. Three configurations shared the lowest DFT among subcutaneous lead ICDs. The Φe gradient criterion was an inadequate predictor of defibrillation success, as defibrillation failed in numerous instances even when 100% of the myocardium experienced such gradients. In conclusion, we have developed a new image processing pipeline and applied it to a CHD patient to construct the first active heart–torso model from clinical MRIs. PMID:23798492
Blosnich, John R; Cashy, John; Gordon, Adam J; Shipherd, Jillian C; Kauth, Michael R; Brown, George R; Fine, Michael J
2018-04-04
Transgender individuals are vulnerable to negative health risks and outcomes, but research remains limited because data sources, such as electronic medical records (EMRs), lack standardized collection of gender identity information. Most EMR do not include the gold standard of self-identified gender identity, but International Classification of Diseases (ICDs) includes diagnostic codes indicating transgender-related clinical services. However, it is unclear if these codes can indicate transgender status. The objective of this study was to determine the extent to which patients' clinician notes in EMR contained transgender-related terms that could corroborate ICD-coded transgender identity. Data are from the US Department of Veterans Affairs Corporate Data Warehouse. Transgender patients were defined by the presence of ICD9 and ICD10 codes associated with transgender-related clinical services, and a 3:1 comparison group of nontransgender patients was drawn. Patients' clinician text notes were extracted and searched for transgender-related words and phrases. Among 7560 patients defined as transgender based on ICD codes, the search algorithm identified 6753 (89.3%) with transgender-related terms. Among 22 072 patients defined as nontransgender without ICD codes, 246 (1.1%) had transgender-related terms; after review, 11 patients were identified as transgender, suggesting a 0.05% false negative rate. Using ICD-defined transgender status can facilitate health services research when self-identified gender identity data are not available in EMR.
Influence of Slippery Pacemaker Leads on Lead-Induced Venous Occlusion
NASA Astrophysics Data System (ADS)
Yang, Weiguang; Bhatia, Sagar; Obenauf, Dayna; Resse, Max; Esmaily-Moghadam, Mahdi; Feinstein, Jeffrey; Pak, On Shun
2016-11-01
The use of medical devices such as pacemakers and implantable cardiac defibrillators have become commonplace to treat arrhythmias. Pacing leads with electrodes are used to send electrical pulses to the heart to treat either abnormally slow heart rates, or abnormal rhythms. Lead induced vessel occlusion, which is commonly seen after placement of pacemaker or ICD leads, may result in lead malfunction and/or SVC syndrome, and makes lead extraction difficult. The association between the anatomic locations at risk for thrombosis and regions of venous stasis have been reported previously. The computational studies reveal obvious flow stasis in the proximity of the leads, due to the no-slip boundary condition imposed on the lead surface. With the advent of recent technologies capable of creating slippery surfaces that can repel complex fluids including blood, we explore computationally how local flow structures may be altered in the regions around the leads when the no-slip boundary condition on the lead surface is relaxed using various slip lengths. The findings evaluate the possibility of mitigating risks of lead-induced thrombosis and occlusion by implementing novel surface conditions (i.e. theoretical coatings) on the leads.
Ogawa, Mikako; Tomita, Yusuke; Nakamura, Yuko; Lee, Min-Jung; Lee, Sunmin; Tomita, Saori; Nagaya, Tadanobu; Sato, Kazuhide; Yamauchi, Toyohiko; Iwai, Hidenao; Kumar, Abhishek; Haystead, Timothy; Shroff, Hari; Choyke, Peter L; Trepel, Jane B; Kobayashi, Hisataka
2017-02-07
Immunogenic cell death (ICD) is a form of cell death that activates an adaptive immune response against dead-cell-associated antigens. Cancer cells killed via ICD can elicit antitumor immunity. ICD is efficiently induced by near-infrared photo-immunotherapy (NIR-PIT) that selectively kills target-cells on which antibody-photoabsorber conjugates bind and are activated by NIR light exposure. Advanced live cell microscopies showed that NIR-PIT caused rapid and irreversible damage to the cell membrane function leading to swelling and bursting, releasing intracellular components due to the influx of water into the cell. The process also induces relocation of ICD bio markers including calreticulin, Hsp70 and Hsp90 to the cell surface and the rapid release of immunogenic signals including ATP and HMGB1 followed by maturation of immature dendritic cells. Thus, NIR-PIT is a therapy that kills tumor cells by ICD, eliciting a host immune response against tumor.
Ramirez-Zamora, Adolfo; Gee, Lucy; Boyd, James; Biller, José
2016-01-01
Impulse control disorders (ICDs) including compulsive gambling, buying, sexual behaviors, and eating occur relatively frequently in Parkinson disease (PD) with at least one ICD identified in 14% of PD patients in a large, multicenter, observational study. ICDs behaviors range widely in severity but can lead to catastrophic consequences, including financial ruin, divorce, loss of employment, and increased health risks. The main risk factor for ICDs in PD is the use of Dopamine agonists (DAs) and discontinuation of the offending agent is considered first line treatment. However, many patients do not tolerate this intervention as consequence of increased motor and psychiatric disability or appearance of DA withdrawal syndrome. In this article, we review current management strategies and emerging new interventions for treatment of ICDs in PD. Pharmacological treatment should be individualized based on patient's unique neuropsychiatric profile, social support, medical comorbidities, tolerability and motor symptoms.
Ploux, Sylvain; Swerdlow, Charles D; Eschalier, Romain; Monteil, Benjamin; Ouali, Sana; Haïssaguerre, Michel; Bordachar, Pierre
2016-07-01
Diaphragmatic myopotential oversensing (DMO) causes inhibition of pacing and inappropriate detection of ventricular fibrillation in implantable cardioverter defibrillators (ICDs). It occurs almost exclusively with integrated bipolar leads and is extremely rare with dedicated bipolar leads. If DMO cannot be corrected by reducing programmed sensitivity, ventricular lead revision is often required. The new Low Frequency Attenuation (LFA) filter in St. Jude Medical ICDs (St. Jude Medical, Sylmar, CA, USA) alters the sensing bandpass to reduce T-wave oversensing. This paper aims to present the LFA filter as a reversible cause of DMO. Unnecessary lead revision can be avoided by the simple programming solution of deactivating this LFA filter. ©2016 Wiley Periodicals, Inc.
Polewczyk, Anna; Jacheć, Wojciech; Janion, Marianna; Podlaski, Rafał; Kutarski, Andrzej
2015-07-01
Lead-dependent infective endocarditis (LDIE) is a serious and insidious infective disease spreading along the leads to valve leaflets and endocardial surface. LDIE is still a lesser known disease with unclear risk factors, most often evaluated jointly for all infectious complications. Clinical data from 414 patients with the diagnosis of LDIE according to the Modified Duke Leads Criteria were analyzed. Patients with LDIE were identified in a population of 1,426 subjects submitted to transvenous lead extraction (TLE) in the Reference Center on Lead Extraction in Lublin, Poland, between March 2006 and July 2013 due to infectious (619 patients-43.4%) and noninfectious (807-56.6% of patients) reasons. During the period of 2006-2011, the analysis was conducted retrospectively; from early 2012 on, patients were enrolled prospectively. The effect of potential risk factors on the development of the disease was evaluated in a comparative analysis of clinical data from the LDIE patients and from 807 subjects with noninfectious indications for TLE. Additionally, in order to identify the factors predisposing to the development of LDIE, the population of infectious patients was divided into three subgroups: with isolated LDIE (157 patients), with LDIE and pocket infection (PI; 257 patients), and with isolated PI (205 patients). The groups and subgroups were analyzed for the presence of patient-dependent risk factors (age, gender, accompanying diseases, anticoagulation, or antiplatelet therapy) and procedure-related risk factors (the number and lead dwell time, pacing system, prior procedures, lead loops, and intracardiac abrasion of the leads). Furthermore, microbes' identification was conducted. The LDIE patients were older (67.3 vs 62.3; P = 0.001) and were more frequently male (68.6% vs 55.0%; P = 0.001) as compared with patients submitted to TLE for noninfectious reasons, but not in comparison with subjects diagnosed with isolated LDIE. In univariate analysis, the independent prognostic factors of LDIE were: type 2 diabetes-increase of risk by 37.7% (hazard ratio [HR] = 1,377; 95% confidence interval [CI] [1,088-1,742]), elevated above 2 mg% creatinine level-increase of risk by 61.5% (HR = 1,615; 95% CI [1,96-2,182]), antiplatelet therapy (HR = 1,285; 95% CI [1,052-1,057]), number of intracardiac leads prior to TLE (HR = 1,199; 95% CI [1,075-1,337]), intracardiac device with implantable cardioverter defibrillator (ICD) lead (HR = 1,909; 95% CI [1,492-2,444]), intracardiac device with coronary sinus lead (HR = 1,411; 95% CI [1,099-1,810]), number of procedures prior to TLE (HR = 1,092; 95% CI [1,017-1,172]), and abrasion of intracardiac leads (HR = 1,350; 95% CI [1,097-1,662]). Multivariate logistic regression demonstrated that the independent risk factors of LDIE were: chronic renal failure (HR = 1,406; 95% CI [1,033-1,915]), number of intracardiac leads prior to TLE (HR = 1,152; 95% CI [1,017-1,305]), intracardiac devices with ICD leads (HR = 1,719; 95% CI [1,330-2,223]), and presence of abrasion of intracardiac leads (HR = 1,405; 95% CI [1,129-1,750]). Microbiological analysis showed the domination of coagulase-negative staphylococci with relative advantage of Staphylococcus epidermidis in pathogenesis of LDIE. The factors predisposing to LDIE are mainly related to procedures performed on the patients. LDIE develops more frequently in patients with multiple leads, especially ICD. An important, until now lesser known, risk factor for LDIE is intracardiac abrasion of the leads strongly connected with procedural agents and properties of specific kind of bacteries. A new concept of the pathogenesis of LDIE was proposed on the basis of present analysis. ©2015 Wiley Periodicals, Inc.
Betsou, Fotini; Beaumont, Katy; Sueur, Jean Marie; Orfila, Jeanne
2003-01-01
An internal control DNA (ICD) with the same primer binding sequences as the target Chlamydia trachomatis DNA was constructed and evaluated in a PCR assay with immunoenzymatic detection. One hundred urine specimens were tested, and 23 were found to contain inhibitors of the PCR, if not subjected to DNA extraction prior to amplification. Coamplification and detection of the ICD appeared to be a useful method for estimating the effects of inhibitors on C. trachomatis DNA amplification. PMID:12624066
Duray, Gabor Z; Schmitt, Joern; Cicek-Hartvig, Sule; Hohnloser, Stefan H; Israel, Carsten W
2009-03-01
Implantable cardioverter defibrillator (ICD) technology has become more complex, particularly with respect to biventricular resynchronization devices. The incidence of hardware-related complications in single (SC)-, dual (DC)-, and triple (BiV)-chamber devices requiring surgical revision has not been investigated systematically. We analysed data from consecutive ICD recipients implanted between January 2000 and December 2007 with respect to the need of surgical re-intervention for device- or lead-related complications. Generator exchanges due to normal battery depletion were not considered. From 816 patients (81% male, 69% ischaemic cardiomyopathy, 48% secondary prevention ICDs) followed for 31 +/- 24 months (2118 cumulative patient-years), 98 patients underwent 110 revisions (5.2% per patient-year). Complications included lead-related revision procedures in 81 cases and generator-related problems in 29 cases. The annual incidence of surgical revision due to complications was 11.8% in BiV compared with 4.9% in SC and 4.1% in DC patients (P = 0.002). This higher revision rate was mainly caused by lead-related complications. Implantation of a BiV system was an independent risk factor of the need for surgical revision (relative risk 2.37, 95% confidence interval 1.38-4.04). Even with long-lasting operator experience, complications requiring surgical revision remain a clinically important problem of ICD therapy. The incidence of complications is significantly higher in BiV resynchronization devices than in SC and DC systems.
Marsh, Laura
2012-01-01
Summary Impulse control disorders (ICD) (most commonly pathologic gambling, hypersexuality, and uncontrollable spending) and compulsive behaviors can be triggered by dopaminergic therapies in Parkinson disease (PD). ICD are especially prevalent in patients receiving a dopamine agonist as part of their treatment regimen for PD, and have also been reported when dopamine agonists are used for other indications (e.g., restless legs syndrome). Although these iatrogenic disorders are common, affecting 1 in 7 patients with PD on dopamine agonists, they often elude detection by the treating physician. ICD lead to serious consequences, causing significant financial loss and psychosocial morbidity for many patients and families. ICD can appear at any time during treatment with dopamine agonists, sometimes within the first few months, but most often after years of treatment, particularly when patients receive dopamine agonists and levodopa together. In most cases ICD resolve if the dopamine agonist is withdrawn, and PD motor symptoms are managed with levodopa monotherapy. Familiarity with the clinical aspects, risk factors, pathophysiology, and management of ICD is essential for physicians using dopaminergic therapies to treat PD and other disorders. PMID:23634371
Muscatiello, Neil; Wilson, Lloyd; Dziewulski, David
2016-01-01
We identified hospital visits with reported exposure to harmful algal blooms, an emerging public health concern because of toxicity and increased incidence. We used the World Health Organization’s International Classification of Disease (ICD) medical code specifying environmental exposure to harmful algal blooms to extract hospital visit records in New York State from 2008 to 2014. Using the ICD code, we identified 228 hospital visits with reported exposure to harmful algal blooms. They occurred all year long and had multiple principal diagnoses. Of all hospital visits, 94.7% were managed in the emergency department and 5.3% were hospitalizations. As harmful algal bloom surveillance increases, the ICD code will be a beneficial tool to public health only if used properly. PMID:26794161
Piątek, Łukasz; Polewczyk, Anna; Kurzawski, Jacek; Zachura, Małgorzata; Kaczmarczyk, Małgorzata; Janion, Marianna
Due to increasing number of patients treated by cardiac implantable electronic devices we observe increasing number of complications after these procedures We analysed causes of early surgical revision of implantable devices connected with 1673 procedures of implantation (871 procedures) or exchange (802 procedures) of pacing systems (PM), cardioverter-difibrillators (ICD) and resynchronisation systems (CRT) in one local centre of electrotherapy in years 2012 to 2015. We characterised risk factors and its influence on encountered complications. In analysed period 72 reinterventions after implantations or exchanges of PM/ICD/CRT were performed. Main causes of early complications were: lead malfunction (2.5%), including the dislodgement of the leads in 1.9%, pocket hematoma (1.4%) and other abnormalities of the pocket (0.4 %), including pocket infections in 0.2%. The most important risk factors of early complications were often implantations of the leads with passive fixation and anticoagulation therapy in perioperative period. The knowledge of the early complications after implantations and exchanges of PM/ICD/CRT should improve the safety of procedures through more often used of the leads with active fixation and properly preparation of the patients requering the antithrombic therapy.
Withania somnifera Induces Cytotoxic and Cytostatic Effects on Human T Leukemia Cells
Turrini, Eleonora; Calcabrini, Cinzia; Sestili, Piero; Catanzaro, Elena; de Gianni, Elena; Diaz, Anna Rita; Hrelia, Patrizia; Tacchini, Massimo; Guerrini, Alessandra; Canonico, Barbara; Papa, Stefano; Valdrè, Giovanni; Fimognari, Carmela
2016-01-01
Cancer chemotherapy is characterized by an elevated intrinsic toxicity and the development of drug resistance. Thus, there is a compelling need for new intervention strategies with an improved therapeutic profile. Immunogenic cell death (ICD) represents an innovative anticancer strategy where dying cancer cells release damage-associated molecular patterns promoting tumor-specific immune responses. The roots of Withania somnifera (W. somnifera) are used in the Indian traditional medicine for their anti-inflammatory, immunomodulating, neuroprotective, and anticancer activities. The present study is designed to explore the antileukemic activity of the dimethyl sulfoxide extract obtained from the roots of W. somnifera (WE). We studied its cytostatic and cytotoxic activity, its ability to induce ICD, and its genotoxic potential on a human T-lymphoblastoid cell line by using different flow cytometric assays. Our results show that WE has a significant cytotoxic and cytostatic potential, and induces ICD. Its proapoptotic mechanism involves intracellular Ca2+ accumulation and the generation of reactive oxygen species. In our experimental conditions, the extract possesses a genotoxic potential. Since the use of Withania is suggested in different contexts including anti-infertility and osteoarthritis care, its genotoxicity should be carefully considered for an accurate assessment of its risk–benefit profile. PMID:27187469
Zabel, Markus; Müller-Riemenschneider, Falk; Geller, J Christoph; Brachmann, Johannes; Kühlkamp, Volker; Dissmann, Rüdiger; Reinhold, Thomas; Roll, Stephanie; Lüthje, Lars; Bode, Frank; Eckardt, Lars; Willich, Stefan N
2014-10-01
Implantable cardioverter defibrillator (ICD) remote follow-up and ICD remote monitoring (RM) are established means of ICD follow-up. The reduction of the number of in-office visits and the time to decision is proven, but the true clinical benefit is still unknown. Cost and cost-effectiveness of RM remain leading issues for its dissemination. The MONITOR-ICD study has been designed to assess costs, cost-effectiveness, and clinical benefits of RM versus standard-care follow-up in a prospective multicenter randomized controlled trial. Patients indicated for single- or dual-chamber ICD are eligible for the study and are implanted an RM-capable Biotronik ICD (Lumax VR-T or Lumax DR-T; Biotronik SE & Co KG, Berlin, Germany). Implantable cardioverter defibrillator programming and alert-based clinical responses in the RM group are highly standardized by protocol. As of December 2011, recruitment has been completed, and 416 patients have been enrolled. Subjects are followed-up for a minimum of 12months and a maximum of 24months, ending in January 2013. Disease-specific costs from a societal perspective have been defined as primary end point and will be compared between RM and standard-care groups. Secondary end points include ICD shocks (including appropriate and inappropriate shocks), cardiovascular hospitalizations and cardiovascular mortality, and additional health economic end points. The MONITOR-ICD study will be an important randomized RM study to report data on a primary economic end point in 2014. Its results on ICD shocks will add to the currently available evidence on clinical benefit of RM. Copyright © 2014 Mosby, Inc. All rights reserved.
Device Longevity in a Contemporary Cohort of ICD/CRT-D Patients Undergoing Device Replacement.
Zanon, Francesco; Martignani, Cristian; Ammendola, Ernesto; Menardi, Endrj; Narducci, Maria Lucia; DE Filippo, Paolo; Santamaria, Matteo; Campana, Andrea; Stabile, Giuseppe; Potenza, Domenico Rosario; Pastore, Gianni; Iori, Matteo; LA Rosa, Concetto; Biffi, Mauro
2016-07-01
The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th-75th percentile, 4.9-6.9) for single- and dual-chamber ICD and 4.9 years (25th-75th percentile, 4.0-5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers. © The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.
Schwitter, Juerg; Gold, Michael R; Al Fagih, Ahmed; Lee, Sung; Peterson, Michael; Ciuffo, Allen; Zhang, Yan; Kristiansen, Nina; Kanal, Emanuel; Sommer, Torsten
2016-05-01
Recently, magnetic resonance (MR)-conditional implantable cardioverter defibrillator (ICD) systems have become available. However, associated cardiac MR image (MRI) quality is unknown. The goal was to evaluate the image quality performance of various cardiac MR sequences in a multicenter trial of patients implanted with an MR-conditional ICD system. The Evera-MRI trial enrolled 275 patients in 42 centers worldwide. There were 263 patients implanted with an Evera-MRI single- or dual-chamber ICD and randomized to controls (n=88) and MRI (n=175), 156 of whom underwent a protocol-required MRI (9-12 weeks post implant). Steady-state-free-precession (SSFP) and fast-gradient-echo (FGE) sequences were acquired in short-axis and horizontal long-axis orientations. Qualitative and quantitative assessment of image quality was performed by using a 7-point scale (grades 1-3: good quality, grades 6-7: nondiagnostic) and measuring ICD- and lead-related artifact size. Good to moderate image quality (grades 1-5) was obtained in 53% and 74% of SSFP and FGE acquisitions, respectively, covering the left ventricle, and in 69% and 84%, respectively, covering the right ventricle. Odds for better image quality were greater for right ventricle versus left ventricle (odds ratio, 1.8; 95% confidence interval, 1.5-2.2; P<0.0001) and greater for FGE versus SSFP (odds ratio, 3.5; 95% confidence interval, 2.5-4.8; P<0.0001). Compared with SSFP, ICD-related artifacts on FGE were smaller (141±65 versus 75±57 mm, respectively; P<0.0001). Lead artifacts were much smaller than ICD artifacts (P<0.0001). FGE yields good to moderate quality in 74% of left ventricle and 84% of right ventricle acquisitions and performs better than SSFP in patients with an MRI-conditional ICD system. In these patients, cardiac MRI can offer diagnostic information in most cases. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02117414. © 2016 American Heart Association, Inc.
Frommeyer, Gerrit; Zumhagen, Sven; Dechering, Dirk G; Larbig, Robert; Bettin, Markus; Löher, Andreas; Köbe, Julia; Reinke, Florian; Eckardt, Lars
2016-03-15
The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the data of a large, standard-of-care prospective single-center S-ICD registry. In the present study, 102 consecutive patients received an S-ICD for primary (n=50) or secondary prevention (n=52). Defibrillation testing was performed in all except 4 patients. In 74 (75%; 95% CI 0.66-0.83) of 98 patients, ventricular fibrillation was effectively terminated by the first programmed internal shock. In 24 (25%; 95% CI 0.22-0.44) of 98 patients, the first internal shock was ineffective and further internal or external shock deliveries were required. In these patients, programming to reversed shock polarity (n=14) or repositioning of the sensing lead (n=1) or the pulse generator (n=5) led to successful defibrillation. In 4 patients, a safety margin of <10 J was not attained. Nevertheless, in these 4 patients, ventricular arrhythmias were effectively terminated with an internal 80-J shock. Although it has been shown that defibrillation testing is not necessary in transvenous ICD systems, it seems particular important for S-ICD systems, because in nearly 25% of the cases the primary intraoperative test was not successful. In most cases, a successful defibrillation could be achieved by changing shock polarity or by optimizing the shock vector caused by the pulse generator or lead repositioning. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Validity of Diagnostic Codes for Acute Stroke in Administrative Databases: A Systematic Review
McCormick, Natalie; Bhole, Vidula; Lacaille, Diane; Avina-Zubieta, J. Antonio
2015-01-01
Objective To conduct a systematic review of studies reporting on the validity of International Classification of Diseases (ICD) codes for identifying stroke in administrative data. Methods MEDLINE and EMBASE were searched (inception to February 2015) for studies: (a) Using administrative data to identify stroke; or (b) Evaluating the validity of stroke codes in administrative data; and (c) Reporting validation statistics (sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), or Kappa scores) for stroke, or data sufficient for their calculation. Additional articles were located by hand search (up to February 2015) of original papers. Studies solely evaluating codes for transient ischaemic attack were excluded. Data were extracted by two independent reviewers; article quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Results Seventy-seven studies published from 1976–2015 were included. The sensitivity of ICD-9 430-438/ICD-10 I60-I69 for any cerebrovascular disease was ≥ 82% in most [≥ 50%] studies, and specificity and NPV were both ≥ 95%. The PPV of these codes for any cerebrovascular disease was ≥ 81% in most studies, while the PPV specifically for acute stroke was ≤ 68%. In at least 50% of studies, PPVs were ≥ 93% for subarachnoid haemorrhage (ICD-9 430/ICD-10 I60), 89% for intracerebral haemorrhage (ICD-9 431/ICD-10 I61), and 82% for ischaemic stroke (ICD-9 434/ICD-10 I63 or ICD-9 434&436). For in-hospital deaths, sensitivity was 55%. For cerebrovascular disease or acute stroke as a cause-of-death on death certificates, sensitivity was ≤ 71% in most studies while PPV was ≥ 87%. Conclusions While most cases of prevalent cerebrovascular disease can be detected using 430-438/I60-I69 collectively, acute stroke must be defined using more specific codes. Most in-hospital deaths and death certificates with stroke as a cause-of-death correspond to true stroke deaths. Linking vital statistics and hospitalization data may improve the ascertainment of fatal stroke. PMID:26292280
Cantwell, Kate; Morgans, Amee; Smith, Karen; Livingston, Michael; Dietze, Paul
2014-02-01
This paper aims to examine whether an adaptation of the International Classification of Disease (ICD) coding system can be applied retrospectively to final paramedic assessment data in an ambulance dataset with a view to developing more fine-grained, clinically relevant case definitions than are available through point-of-call data. Over 1.2 million case records were extracted from the Ambulance Victoria data warehouse. Data fields included dispatch code, cause (CN) and final primary assessment (FPA). Each FPA was converted to an ICD-10-AM code using word matching or best fit. ICD-10-AM codes were then converted into Major Diagnostic Categories (MDC). CN was aligned with the ICD-10-AM codes for external cause of morbidity and mortality. The most accurate results were obtained when ICD-10-AM codes were assigned using information from both FPA and CN. Comparison of cases coded as unconscious at point-of-call with the associated paramedic assessment highlighted the extra clinical detail obtained when paramedic assessment data are used. Ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Coding of ambulance data using ICD-10-AM allows for comparison of not only ambulance service users but also with other population groups. WHAT IS KNOWN ABOUT THE TOPIC? There is no reliable and standard coding and categorising system for paramedic assessment data contained in ambulance service databases. WHAT DOES THIS PAPER ADD? This study demonstrates that ambulance paramedic assessment data can be aligned with ICD-10-AM and MDC with relative ease, allowing retrospective coding of large datasets. Representation of ambulance case types using ICD-10-AM-coded information obtained after paramedic assessment is more fine grained and clinically relevant than point-of-call data, which uses caller information before ambulance attendance. WHAT ARE THE IMPLICATIONS FOR PRACTITIONERS? This paper describes a model of coding using an internationally recognised standard coding and categorising system to support analysis of paramedic assessment. Ambulance data coded using ICD-10-AM allows for reliable reporting and comparison within the prehospital setting and across the healthcare industry.
Jouhet, Vianney; Mougin, Fleur; Bréchat, Bérénice; Thiessard, Frantz
2017-02-07
Identifying incident cancer cases within a population remains essential for scientific research in oncology. Data produced within electronic health records can be useful for this purpose. Due to the multiplicity of providers, heterogeneous terminologies such as ICD-10 and ICD-O-3 are used for oncology diagnosis recording purpose. To enable disease identification based on these diagnoses, there is a need for integrating disease classifications in oncology. Our aim was to build a model integrating concepts involved in two disease classifications, namely ICD-10 (diagnosis) and ICD-O-3 (topography and morphology), despite their structural heterogeneity. Based on the NCIt, a "derivative" model for linking diagnosis and topography-morphology combinations was defined and built. ICD-O-3 and ICD-10 codes were then used to instantiate classes of the "derivative" model. Links between terminologies obtained through the model were then compared to mappings provided by the Surveillance, Epidemiology, and End Results (SEER) program. The model integrated 42% of neoplasm ICD-10 codes (excluding metastasis), 98% of ICD-O-3 morphology codes (excluding metastasis) and 68% of ICD-O-3 topography codes. For every codes instantiating at least a class in the "derivative" model, comparison with SEER mappings reveals that all mappings were actually available in the model as a link between the corresponding codes. We have proposed a method to automatically build a model for integrating ICD-10 and ICD-O-3 based on the NCIt. The resulting "derivative" model is a machine understandable resource that enables an integrated view of these heterogeneous terminologies. The NCIt structure and the available relationships can help to bridge disease classifications taking into account their structural and granular heterogeneities. However, (i) inconsistencies exist within the NCIt leading to misclassifications in the "derivative" model, (ii) the "derivative" model only integrates a part of ICD-10 and ICD-O-3. The NCIt is not sufficient for integration purpose and further work based on other termino-ontological resources is needed in order to enrich the model and avoid identified inconsistencies.
Knackstedt, Christian; Arndt, Marlies; Mischke, Karl; Marx, Nikolaus; Nieman, Fred; Kunert, Hanns Jürgen; Schauerte, Patrick; Norra, Christine
2014-05-01
Congestive heart failure is frequent and leads to reduced exercise capacity, reduced quality of life (QoL), and depression in many patients. Cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD) offer therapeutic options and may have an impact on QoL and depression. This study was performed to evaluate physical and mental health in patients undergoing ICD or combined CRT/ICD-implantation (CRT-D). Echocardiography, spiroergometry, and psychometric questionnaires [Beck Depression Inventory, General World Health Organization Five Well-being Index (WHO-5), Brief Symptom Inventory and 36-item Short Form (SF-36)] were obtained in 39 patients (ICD: 17, CRT-D: 22) at baseline and 6-month follow-up (FU) after device implantation. CRT-D patients had a higher NYHA class and broader left bundle branch block than ICD patients at baseline. At FU, ejection fraction (EF), peak oxygen uptake, and NYHA class improved significantly in CRT-D patients but remained unchanged in ICD patients. Patients with CRT-D implantation showed higher levels of depressive symptoms, psychological distress, and impairment in QoL at baseline and FU compared to ICD patients. These impairments remained mostly unchanged in all patients after 6 months. Overall, these findings imply that there is a need for careful assessment and treatment of psychological distress and depression in ICD and CRT-D patients in the course of device implantation as psychological burden seems to persist irrespective of physical improvement.
Fiek, Michael; Dorwarth, Uwe; Durchlaub, Ilka; Janko, Sabine; Von Bary, Christian; Steinbeck, Gerhard; Hoffmann, Ellen
2004-03-01
During surgical and interventional procedures, interference may occur between ICDs and electrical cautery or with the application of RF energy. This may lead to the false induction of ICD therapies or could even result in device malfunction, which represents a potential perioperative hazard for the patient. This study analyzed the intraoperative interactions in 45 consecutive ICD patients in reference to different surgical and interventional procedures. A total of 33 surgical operations (general surgery [n = 14], urologic [n = 5], abdominal [n = 10], gynecological [n = 2], thoracic [n = 1], neurosurgical [n = 1]) and 12 interventional therapies (RF catheter ablation [n = 10], endoscopic papillotomy [n = 2]) were performed. The ICD devices were all located in left pectoral position and consisted of 25 single and 20 dual chamber defibrillators. During the procedure, tachyarrhythmia detection (VF 296 +/- 20 ms, VT 376 +/- 49 ms) of the devices was maintained active (monitoring mode), only ICD therapies were inactivated. The indifferent electrode of the electrical cauter/RF generator was placed in standard positions (right/left mid-femoral position [n = 27/8], thoracic spine area [n = 10]). After the procedure, the ICD memory was checked for detections and for changes in the programming. There was no oversensing, reprogramming, or damage of any defibrillator caused by RF energy. Despite the lack of undesired interactions, ICDs should be inactivated preoperatively to assure maximum patient safety. However, should inactivation not be possible, or the achievement uncertain, electromagnetic interference is highly unlikely.
Comparison of procedure coding systems for level 1 and 2 hospitals in South Africa.
Montewa, Lebogang; Hanmer, Lyn; Reagon, Gavin
2013-01-01
The ability of three procedure coding systems to reflect the procedure concepts extracted from patient records from six hospitals was compared, in order to inform decision making about a procedure coding standard for South Africa. A convenience sample of 126 procedure concepts was extracted from patient records at three level 1 hospitals and three level 2 hospitals. Each procedure concept was coded using ICPC-2, ICD-9-CM, and CCSA-2001. The extent to which each code assigned actually reflected the procedure concept was evaluated (between 'no match' and 'complete match'). For the study sample, CCSA-2001 was found to reflect the procedure concepts most completely, followed by ICD-9-CM and then ICPC-2. In practice, decision making about procedure coding standards would depend on multiple factors in addition to coding accuracy.
Au-yeung, Wan-tai M.; Reinhall, Per; Poole, Jeanne E.; Anderson, Jill; Johnson, George; Fletcher, Ross D.; Moore, Hans J.; Mark, Daniel B.; Lee, Kerry L.; Bardy, Gust H.
2015-01-01
Background In the SCD-HeFT a significant fraction of the congestive heart failure (CHF) patients ultimately did not die suddenly from arrhythmic causes. CHF patients will benefit from better tools to identify if ICD therapy is needed. Objective To identify predictor variables from baseline SCD-HeFT patients’ RR intervals that correlate to arrhythmic sudden cardiac death (SCD) and mortality and to design an ICD therapy screening test. Methods Ten predictor variables were extracted from pre-randomization Holter data from 475 patients enrolled in the SCD-HeFT ICD arm using novel and traditional heart rate variability methods. All variables were correlated to SCD using Mann Whitney-Wilcoxon test and receiver operating characteristic analysis. ICD therapy screening tests were designed by minimizing the cost of false classifications. Survival analysis, including log-rank test and Cox models, was also performed. Results α1 and α2 from detrended fluctuation analysis, the ratio of low to high frequency power, the number of PVCs per hour and heart rate turbulence slope are all statistically significant for predicting the occurrences of SCD (p<0.001) and survival (log-rank p<0.01). The most powerful multivariate predictor tool using the Cox Proportional Hazards was α2 with a hazard ratio of 0.0465 (95% CI: 0.00528 – 0.409, p<0.01). Conclusion Predictor variables from RR intervals correlate to the occurrences of SCD and distinguish survival among SCD-HeFT ICD patients. We believe SCD prediction models should incorporate Holter based RR interval analysis to refine ICD patient selection especially in removing patients who are unlikely to benefit from ICD therapy. PMID:26096609
Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia
2015-01-01
The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Campbell, Peter G; Malone, Jennifer; Yadla, Sanjay; Chitale, Rohan; Nasser, Rani; Maltenfort, Mitchell G; Vaccaro, Alex; Ratliff, John K
2011-01-01
large studies of ICD-9-based complication and hospital-acquired condition (HAC) chart reviews have not been validated through a comparison with prospective assessments of perioperative adverse event occurrence. Retrospective chart review, while generally assumed to underreport complication occurrence, has not been subjected to prospective study. It is unclear whether ICD-9-based population studies are more accurate than retrospective reviews or are perhaps equally susceptible to bias. To determine the validity of an ICD-9-based assessment of perioperative complications, the authors compared a prospective independent evaluation of such complications with ICD-9-based HAC data in a cohort of patients who underwent spine surgery. For further comparison, a separate retrospective review of the same cohort of patients was completed as well. a prospective assessment of complications in spine surgery over a 6-month period (May to December 2008) was completed using an independent auditor and a validated definition of perioperative complications. The auditor maintained a prospective database, which included complications occurring in the initial 30 days after surgery. All medical adverse events were included in the assessment. All patients undergoing spine surgery during the study period were eligible for inclusion; the only exclusionary criterion used was the availability of the auditor for patient assessment. From the overall patient database, 100 patients were randomly extracted for further review; in these patients ICD-9-based HAC data were obtained from coder data. Separately, a retrospective assessment of complication incidence was completed using chart and electronic medical record review. The same definition of perioperative adverse events and the inclusion of medical adverse events were applied in the prospective, ICD-9-based, and retrospective assessments. ninety-two patients had adequate records for the ICD-9 assessment, whereas 98 patients had adequate chart information for retrospective review. The overall complication incidence among the groups was similar (major complications: ICD-9 17.4%, retrospective 19.4%, and prospective 22.4%; minor complications: ICD-9 43.8%, retrospective 31.6%, and prospective 42.9%). However, the ICD-9-based assessment included many minor medical events not deemed complications by the auditor. Rates of specific complications were consistently underreported in both the ICD-9 and the retrospective assessments. The ICD-9 assessment underreported infection, the need for reoperation, deep wound infection, deep venous thrombosis, and new neurological deficits (p = 0.003, p < 0.0001, p < 0.0001, p = 0.0025, and p = 0.04, respectively). The retrospective review underestimated incidences of infection, the need for revision, and deep wound infection (p < 0.0001 for each). Only in the capture of new cardiac events was ICD-9-based reporting more accurate than prospective data accrual (p = 0.04). The most sensitive measure for the appreciation of complication occurrence was the prospective review, followed by the ICD-9-based assessment (p = 0.05). an ICD-9-based coding of perioperative adverse events and major complications in a cohort of spine surgery patients revealed an overall complication incidence similar to that in a prospectively executed measure. In contrast, a retrospective review underestimated complication incidence. The ICD-9-based review captured many medical events of limited clinical import, inflating the overall incidence of adverse events demonstrated by this approach. In multiple categories of major, clinically significant perioperative complications, ICD-9-based and retrospective assessments significantly underestimated complication incidence. These findings illustrate a significant potential weakness and source of inaccuracy in the use of population-based ICD-9 and retrospective complication recording.
Bettin, Markus; Rath, Benjamin; Ellermann, Christian; Leitz, Patrick; Reinke, Florian; Köbe, Julia; Eckardt, Lars; Frommeyer, Gerrit
2018-06-12
The subcutaneous ICD is a promising treatment option in patients at risk for sudden cardiac death. Approved in 2009, the first S-ICD ® in Germany was implanted in June 2010. Although large prospective registry studies have shown safety and efficacy of the system, there is a lack of long-term data with regard to battery longevity of the S-ICD ® . Therefore, we report follow-up of our first initial S-ICD ® cases from implantation till battery depletion. All S-ICD ® patients with device replacement for battery depletion in our large single-center S-ICD ® registry were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a median follow-up of 75.9 ± 6.8 months. Twenty-eight patients with S-ICD ® systems were included in this study. Of these patients, 21 were male and 7 were female, with an overall mean age of 41.9 ± 12.6 years. Primary prevention of sudden cardiac death was the indication in 19 patients (67.9%). Ventricular tachycardia was adequately terminated in two patients (7.1%). In 7 patients, non-sustained ventricular arrhythmias were not treated. A total of three inappropriate shocks occurred in three patients (10.7%). Mean time from implantation till battery depletion was 65.8 ± 8.1 months. Only one patient presented premature elective replacement criteria because of rapid battery depletion. No lead-related complication occurred during follow-up and no complications were seen regarding device replacement. In one patient (3.6%), the system was explanted without replacement due to patient's preference. The estimated battery longevity of S-ICD ® of about 5 years was reached in all but one patient. Compared to larger S-ICD ® registry studies, frequency of inappropriate shocks was relatively high in the initial S-ICD ® cases. Both technological improvement as well as programming and operators' experience have led to a reduction of complications. Replacement of the S-ICD ® seems to be a safe and effective procedure.
Treskes, Roderick Willem; van der Velde, Enno Tjeerd; Barendse, Rogier; Bruining, Nico
2016-09-01
Recent developments in implantable cardioverter-defibrillators (ICDs) and smartphone technology have increased the possibilities for remote monitoring. It is the purpose of this review to give an overview of these new possibilities. Remote monitoring in ICD allows for early detection of lead fractures and remote follow-up of patients. Possible limitations are the lack of standardization and the possible unsafety of the data stored on the ICD. Secondly, remote monitoring of health parameters using smartphone compatible wearables and smartphone medical apps is addressed. Possible limitations include the fact that the majority of smartphone apps are unregulated by the regulatory authorities and privacy issues such as selling of app-generated data to third parties. Lastly, clinical studies with smartphone apps are discussed. Expert commentary: New technologies in ICDs and smartphones have the potential to be used for remote monitoring. However, unreliability of smartphone technology, inadequate legislation and lack of reimbursement impede implementation.
Godemann, F; Ahrens, B; Behrens, S; Berthold, R; Gandor, C; Lampe, F; Linden, M
2001-01-01
A model for the development of anxiety disorders (panic disorder with or without agoraphobia) is needed. Patients with an implantable cardioverter/defibrillator (ICD) are exposed to repeated electric shocks. If the theory of anxiety development by aversive classic conditioning processes is valid, these repeated shocks should lead to an increased risk of anxiety disorders. To study this hypothesis, we retrospectively studied 72 patients after implantation of an automatic ICD. Patients were assessed with the semistructured Diagnostic Interview of Psychiatric Disease 1 to 6 years after implantation of an automatic ICD. Panic disorder and/or agoraphobia was diagnosed in patients who fulfilled all DSM-III-R criteria for those conditions. Anxiety disorder developed in 15.9% of patients after ICD implantation. This was significantly related to the frequency of repeated defibrillation (shocks) to stop malignant ventricular arrhythmias. Dysfunctional cognitions are an additional vulnerability factor. The data support both the conditioning hypothesis and the cognitive model of anxiety development. These findings suggest that ICD patients are an appropriate risk population for a prospective study of the development of anxiety disorders.
Manchikanti, Laxmaiah; Kaye, Alan D; Singh, Vijay; Boswell, Mark V
2015-01-01
The forced implementation of ICD-10-CM (International Classification of Diseases, Tenth Revision, Clinical Modification) codes that are specific to the United States, scheduled for implementation October 1, 2015, which is vastly different from ICD-10 (International Classification of Diseases, Tenth Revision), implemented worldwide, which has 14,400 codes, compared to ICD-10-CM with 144,000 codes to be implemented in the United States is a major concern to practicing U.S. physicians and a bonanza for health IT and hospital industry. This implementation is based on a liberal interpretation of the Health Insurance Portability and Accountability Act (HIPAA), which requires an update to ICD-9-CM (International Classification of Diseases, Ninth Revision, Clinical Modification) and says nothing about ICD-10 or beyond. On June 29, 2015, the Supreme Court ruled that the Environmental Protection Agency unreasonably interpreted the Clean Air Act when it decided to set limits on the emissions of toxic pollutants from power plants, without first considering the costs on the industry. Thus, to do so is applicable to the medical industry with the Centers for Medicare and Medicaid Services (CMS) unreasonably interpreting HIPAA and imposing existent extensive regulations without considering the cost. In the United States, ICD-10-CM with a 10-fold increase in the number of codes has resulted in a system which has become so complicated that it no longer compares with any other country. Moreover, most WHO members use the ICD-10 system (not ICD-10-CM) only to record mortality in 138 countries or morbidity in 99 countries. Currently, only 10 countries employ ICD-10 (not ICD-10-CM) in the reimbursement process, 6 of which have a single payer health care system. Development of ICD-10-CM is managed by 4 non-physician groups, known as cooperating parties. They include the Centers for Disease Control and Prevention (CDC), CMS, the American Hospital Association (AHA), and the American Health Information Management Association (AHIMA). The AHIMA has taken the lead with the AHA just behind, both with escalating profits and influence, essentially creating a statutory monopoly for their own benefit. Further, the ICD-10-CM coalition includes 3M which will boost its revenues and profits substantially with its implementation and Blue Cross Blue Shield which has its own agenda. Physician groups are not a party to these cooperating parties or coalitions, having only a peripheral involvement. ICD-10-CM creates numerous deficiencies with 500 codes that are more specific in ICD-9-CM than ICD-10-CM. The costs of an implementation are enormous, along with maintenance costs, productivity, and cash disruptions.
Hergenhahn, Uwe
2012-12-01
The paper gives an introduction into Interatomic and Intermolecular Coulombic Decay (ICD). ICD is an autoionization process, which contrary to Auger decay involves neighbouring sites of the initial vacancy as an integral part of the decay transition. As a result of ICD, slow electrons are produced which generally are known to be active in radiation damage. The author summarizes the properties of ICD and reviews a number of important experiments performed in recent years. Intermolecular Coulombic Decay can generally take place in weakly bonded aggregates in the presence of ionizing particles or ionizing radiation. Examples collected here mostly use soft X-rays produced by synchrotron radiation to ionize, and use rare-gas clusters, water clusters or solutes in a liquid jet to observe ICD after irradiation. Intermolecular Coulombic Decay is initiated by single ionization into an excited state. The subsequent relaxation proceeds via an ultra-fast energy transfer to a neighbouring site, where a second ionization occurs. Secondary electrons from ICD have clearly been identified in numerous systems. ICD can take place after primary ionization, as the second step of a decay cascade which also involves Auger decay, or after resonant excitation with an energy which exceeds the ionization potential of the system. ICD is expected to play a role whenever particles or radiation with photon energies above the ionization energies for inner valence electrons are present in weakly bonded matter, e.g., biological tissue. The process produces at the same time a slow electron and two charged atomic or molecular fragments, which will lead to structural changes around the ionized site.
Canham-Chervak, Michelle; Steelman, Ryan A; Schuh, Anna; Jones, Bruce H
2016-11-01
Injuries are a barrier to military medical readiness, and overexertion has historically been a leading mechanism of injury among active duty U.S. Army soldiers. Details are needed to inform prevention planning. The Defense Medical Surveillance System (DMSS) was queried for unique medical encounters among active duty Army soldiers consistent with the military injury definition and assigned an overexertion external cause code (ICD-9: E927.0-E927.9) in 2014 (n=21,891). Most (99.7%) were outpatient visits and 60% were attributed specifically to sudden strenuous movement. Among the 41% (n=9,061) of visits with an activity code (ICD-9: E001-E030), running was the most common activity (n=2,891, 32%); among the 19% (n=4,190) with a place of occurrence code (ICD-9: E849.0-E849.9), the leading location was recreation/sports facilities (n=1,332, 32%). External cause codes provide essential details, but the data represented less than 4% of all injury-related medical encounters among U.S. Army soldiers in 2014. Efforts to improve external cause coding are needed, and could be aligned with training on and enforcement of ICD-10 coding guidelines throughout the Military Health System.
Rist, J.; Miteva, T.; Gaire, B.; ...
2016-09-15
In this paper we present a comprehensive and detailed study of Interatomic Coulombic Decay (ICD) occurring after irradiating argon dimers with XUV-synchrotron radiation. A manifold of different decay channels is observed and the corresponding initial and final states are assigned. Additionally, the effect of nuclear dynamics on the ICD electron spectrum is examined for one specific decay channel. The internuclear distance-dependent width Γ(R) of the decay is obtained from the measured kinetic energy release distribution of the ions employing a classical nuclear dynamics model.
Gagné, Mathieu; Moore, Lynne; Beaudoin, Claudia; Batomen Kuimi, Brice Lionel; Sirois, Marie-Josée
2016-03-01
The International Classification of Diseases (ICD) is the main classification system used for population-based injury surveillance activities but does not contain information on injury severity. ICD-based injury severity measures can be empirically derived or mapped, but no single approach has been formally recommended. This study aimed to compare the performance of ICD-based injury severity measures to predict in-hospital mortality among injury-related admissions. A systematic review and a meta-analysis were conducted. MEDLINE, EMBASE, and Global Health databases were searched from their inception through September 2014. Observational studies that assessed the performance of ICD-based injury severity measures to predict in-hospital mortality and reported discriminative ability using the area under a receiver operating characteristic curve (AUC) were included. Metrics of model performance were extracted. Pooled AUC were estimated under random-effects models. Twenty-two eligible studies reported 72 assessments of discrimination on ICD-based injury severity measures. Reported AUC ranged from 0.681 to 0.958. Of the 72 assessments, 46 showed excellent (0.80 ≤ AUC < 0.90) and 6 outstanding (AUC ≥ 0.90) discriminative ability. Pooled AUC for ICD-based Injury Severity Score (ICISS) based on the product of traditional survival proportions was significantly higher than measures based on ICD mapped to Abbreviated Injury Scale (AIS) scores (0.863 vs. 0.825 for ICDMAP-ISS [p = 0.005] and ICDMAP-NISS [p = 0.016]). Similar results were observed when studies were stratified by the type of data used (trauma registry or hospital discharge) or the provenance of survival proportions (internally or externally derived). However, among studies published after 2003 the Trauma Mortality Prediction Model based on ICD-9 codes (TMPM-9) demonstrated superior discriminative ability than ICISS using the product of traditional survival proportions (0.850 vs. 0.802, p = 0.002). Models generally showed poor calibration. ICISS using the product of traditional survival proportions and TMPM-9 predict mortality more accurately than those mapped to AIS codes and should be preferred for describing injury severity when ICD is used to record injury diagnoses. Systematic review and meta-analysis, level III.
Frozen shoulder syndrome associated with subpectoral defibrillator implantation.
Burke, M C; Drinan, K; Kopp, D E; Kall, J G; Verdino, R J; Paydak, H; Wilber, D J
1999-10-01
Pectoral implantation of transvenous non-thoracotomy internal cardioverter defibrillators (ICD) has resulted in very few complications whether placed subpectorally or subcutaneously. We report the case of a 68 year old man with a subpectorally implanted MINI-plus (Cardiac Pacemakers, Incorporated, St. Paul, Mn.) transvenous ICD who developed nearly instantaneous severe ipsilateral shoulder pain and immobilization. The symptoms progressed despite aggressive physical therapy. We elected to remove the device from the pectoral site and place it in a traditional abdominal position due to the severity, duration and refractoriness of his symptoms. This procedure utilized the chronic Endotak DSP (Model 0125, Cardiac Pacemakers, Incorporated) transvenous lead, a compatible Endotak DSP lead extender (Model 6952, Cardiac Pacemakers, Incorporated) and the above described ICD. Immediate relief of symptoms was accomplished by relocation of the device to an abdominal site. This intervention should be reserved for patients with severely debilitating symptoms. Prospective comparison of subpectoral and subcutaneous surgical approaches with respect to patient comfort and acceptance and complications may be warranted.
Evaluating Open-Source Full-Text Search Engines for Matching ICD-10 Codes.
Jurcău, Daniel-Alexandru; Stoicu-Tivadar, Vasile
2016-01-01
This research presents the results of evaluating multiple free, open-source engines on matching ICD-10 diagnostic codes via full-text searches. The study investigates what it takes to get an accurate match when searching for a specific diagnostic code. For each code the evaluation starts by extracting the words that make up its text and continues with building full-text search queries from the combinations of these words. The queries are then run against all the ICD-10 codes until a match indicates the code in question as a match with the highest relative score. This method identifies the minimum number of words that must be provided in order for the search engines choose the desired entry. The engines analyzed include a popular Java-based full-text search engine, a lightweight engine written in JavaScript which can even execute on the user's browser, and two popular open-source relational database management systems.
Webster, Gregory; Jordao, Ligia; Martuscello, Maria; Mahajan, Tarun; Alexander, Mark E; Cecchin, Frank; Triedman, John K; Walsh, Edward P; Berul, Charles I
2008-04-01
Concern exists regarding the potential electromagnetic interaction between pacemakers, implantable cardioverter-defibrillators (ICDs) and digital music players (DMPs). A preliminary study reported interference in 50% of patients whose devices were interrogated near Apple iPods. Given the high prevalence of DMP use among young patients, we sought to define the nature of interference from iPods and evaluate other DMPs. Four DMPs (Apple Nano, Apple Video, SanDisk Sansa and Microsoft Zune) were evaluated against pacemakers and ICDs (PM/ICD). Along with continuous monitoring, we recorded a baseline ECG strip, sensing parameters and lead impedance at baseline and for each device. Among 51 patients evaluated (age 6 to 60 years, median 22), there was no interference with intrinsic device function. Interference with the programmer occurred in 41% of the patients. All four DMPs caused programmer interference, including disabled communication between the PM/ICD and programmer, noise in the ECG channel, and lost marker channel indicators. Sensing parameters and lead impedances exhibited no more than baseline variability. When the DMPs were removed six inches, there were no further programmer telemetry interactions. Contrary to a prior report, we did not identify any evidence for electromagnetic interference between a selection of DMPs and intrinsic function of PM/ICDs. The DMPs did sometimes interfere with device-programmer communication, but not in a way that compromised device function. Therefore, we recommend that DMPs not be used during device interrogation, but suggest that there is reassuring counterevidence to mitigate the current high level of concern for interactions between DMPs and implantable cardiac rhythm devices.
Roguin, Ariel; Zviman, Menekhem M.; Meininger, Glenn R.; Rodrigues, E. Rene; Dickfeld, Timm M.; Bluemke, David A.; Lardo, Albert; Berger, Ronald D.; Calkins, Hugh; Halperin, Henry R.
2011-01-01
Background MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. Methods and Results We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes <0.5°C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was <100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (n=18), and after 4 weeks, 3- to 4-hour MR scans were performed (n=15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (<12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (n=3) not subjected to MRI. Conclusions These data suggest that certain modern pacemaker and ICD systems may indeed be MRI safe. This may have major clinical implications for current imaging practices. PMID:15277324
Thibault, Bernard; Roy, Denis; Guerra, Peter G; Macle, Laurent; Dubuc, Marc; Gagné, Pierre; Greiss, Isabelle; Novak, Paul; Furlani, Aldo; Talajic, Mario
2005-07-01
Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.
Fauchier, Laurent; Alonso, Christine; Anselme, Frédéric; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jérôme; Piot, Olivier; Hanon, Olivier
2016-09-01
Despite the increasingly high rate of implantation of pacemakers (PM) and cardioverter-defibrillators (ICD) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety, and effectiveness of the conventional pacing, ICD and cardiac resynchronization therapy (CRT) in elderly patients. Although peri-procedural risk may be slightly higher in the elderly, the procedure of implantation of PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, a general consensus is that dual chamber pacing, along with the programming of an algorithm to minimise ventricular pacing is preferred. In very old patients presenting with intermittent or suspected AV block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is comparable in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantage of the device on arrhythmic death may be attenuated by a higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live >5-7 years after implantation. The elderly patients usually experience a significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non responders remains globally the same, while considering a less aggressive approach in terms of re interventions (revision of LV lead placement, addition of a RV or LV lead, LV endocardial pacing configuration). Overall, age, comorbidities and comprehensive geriatric assessment should be the decisive factor in making a decision on device implantation selection for survival and well-being benefit in elderly patients.
Lampert, Rachel; Cannom, David; Olshansky, Brian
2006-01-01
Safety of Sports for ICD Patients. The safety of sports participation for patients with implantable cardioverter defibrillators (ICDs) is unknown, and recommendations among physicians may vary widely. The purposes of this study were to determine current practice among patients with ICDs and their physicians regarding sports participation, and to determine how many physicians have cared for patients who have sustained adverse events during sports participation. A survey was mailed to all 1,687 U.S. physician members of the Heart Rhythm Society. Among 614 respondent physicians, recommendations varied widely. Only 10% recommended avoidance of all sports more vigorous than golf. Seventy-six percent recommended avoidance of contact, and 45% recommend avoidance of competitive sports. Most (71%) based restrictions on patients' underlying heart disease. Regardless of recommendations, most physicians (71%) reported caring for patients who participated in sports, including many citing vigorous, competitive sports, most commonly cited were basketball, running, and skiing. ICD shocks during sports were common, cited by 40% of physicians. However, few adverse consequences were reported. One percent of physicians reported known injury to patient (all but 3 minor); 5%, injury to the ICD system, and <1%, failure of shocks to terminate arrhythmia. The most common adverse event reported was lead damage attributed to repetitive-motion activities, most commonly weightlifting and golf. Physician recommendations for sports participation for patients with ICDs varies widely. Many patients with ICDs do participate in vigorous and even competitive sports. While shocks were common, significant adverse events were rare.
Lim, Tien Siang Eric; Tan, Boon Yew; Ho, Kah Leng; Lim, Chuh Yih Paul; Teo, Wee Siong; Ching, Chi-Keong
2015-01-01
Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore. PMID:26512151
Lim, Tien Siang Eric; Tan, Boon Yew; Ho, Kah Leng; Lim, Chuh Yih Paul; Teo, Wee Siong; Ching, Chi-Keong
2015-10-01
Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.
The Value of Electronically Extracted Data for Auditing Outpatient Antimicrobial Prescribing.
Livorsi, Daniel J; Linn, Carrie M; Alexander, Bruce; Heintz, Brett H; Tubbs, Traviss A; Perencevich, Eli N
2018-01-01
OBJECTIVE The optimal approach to auditing outpatient antimicrobial prescribing has not been established. We assessed how different types of electronic data-including prescriptions, patient-visits, and International Classification of Disease, Tenth Revision (ICD-10) codes-could inform automated antimicrobial audits. DESIGN Outpatient visits during 2016 were retrospectively reviewed, including chart abstraction, if an antimicrobial was prescribed (cohort 1) or if the visit was associated with an infection-related ICD-10 code (cohort 2). Findings from cohorts 1 and 2 were compared. SETTING Primary care clinics and the emergency department (ED) at the Iowa City Veterans Affairs Medical Center. RESULTS In cohort 1, we reviewed 2,353 antimicrobial prescriptions across 52 providers. ICD-10 codes had limited sensitivity and positive predictive value (PPV) for validated cases of cystitis and pneumonia (sensitivity, 65.8%, 56.3%, respectively; PPV, 74.4%, 52.5%, respectively). The volume-adjusted antimicrobial prescribing rate was 13.6 per 100 ED visits and 7.5 per 100 primary care visits. In cohort 2, antimicrobials were not indicated in 474 of 851 visits (55.7%). The antimicrobial overtreatment rate was 48.8% for the ED and 59.7% for primary care. At the level of the individual prescriber, there was a positive correlation between a provider's volume-adjusted antimicrobial prescribing rate and the individualized rates of overtreatment in both the ED (r=0.72; P<.01) and the primary care setting (r=0.82; P=0.03). CONCLUSIONS In this single-center study, ICD-10 codes had limited sensitivity and PPV for 2 infections that typically require antimicrobials. Electronically extracted data on a provider's rate of volume-adjusted antimicrobial prescribing correlated with the frequency at which unnecessary antimicrobials were prescribed, but this may have been driven by outlier prescribers. Infect Control Hosp Epidemiol 2018;39:64-70.
Srinivasan, Neil T; Patel, Kiran H; Qamar, Kashif; Taylor, Amy; Bacà, Marco; Providência, Rui; Tome-Esteban, Maria; Elliott, Perry M; Lambiase, Pier D
2017-04-01
The features of the hypertrophic cardiomyopathy (HCM) ECG make it a challenge for subcutaneous implantable cardioverter-defibrillator (S-ICD) screening. We aimed to investigate the causes of screening failure at rest and on exercise to inform optimal S-ICD ECG vector development. One hundred and thirty-one HCM patients (age, 50±16 years; 92 males and 39 females) with ≥1 HCM risk factor for sudden death underwent S-ICD ECG screening at rest and on exercise. Fifty patients (38%) were ineligible for S-ICD because of screening failure in every lead vector: 33 (66%) failed in the supine position, 12 (24%) failed in the standing position, and 5 (10%) failed on exercise. In patients who could exercise and passed screening at rest, 31 (44%) had 1 vector safety, 16 (23%) had 2 vector safety, and 24 (33%) had 3 vector safety. Increased R:T wave ratio in the S-ICD screening ECG (odds ratio, 4.0; confidence interval, 3.0-5.3; P <0.001) was associated with screening failure, while R/T ratio <3 in aVF (odds ratio, 0.3; confidence interval, 0.12-0.69; P =0.006) and increasing age (odds ratio, 0.97; confidence interval, 0.95-0.99; P =0.03) was associated with reduced screening failure. European Society of Cardiology risk score was higher in those failing screening (risk score 5.5% [interquartile range, 3.2-8.7] in failed versus 4.5% [interquartile range, 2.9-7.4] in passed; P =0.04). HCM patients have a significant incidence of screening failure, which is determined primarily by the increased R:T ratio on the screening ECG and lead aVF. High-risk patients have an increased screening failure rate. Optimization of sensing algorithms is required to ensure that the highest risk HCM patients can benefit from S-ICD implantation. © 2017 American Heart Association, Inc.
Weinstock, Jonathan; Bader, Yousef H; Maron, Martin S; Rowin, Ethan J; Link, Mark S
2016-02-12
The subcutaneous implantable cardioverter defibrillator (S-ICD) has been developed to avert risks associated with transvenous defibrillator leads. The technology is attractive for younger patients, such as those with hypertrophic cardiomyopathy (HCM). However, there are limited data on S-ICD use in HCM. HCM patients identified at risk for sudden death were considered for S-ICD implantation. Patients were screened for potential oversensing by surface electrocardiography (ECG). At implant, defibrillation threshold (DFT) testing was performed at 65, 50, and 35 joules (J). Twenty-seven patients were considered for S-ICD implantation, and after screening, 23 (85%) remained eligible. The presence of a bundle branch block was associated with screening failure, whereas elevated body mass index (BMI) showed a trend toward association. One patient passed screening at rest, but failed with an ECG obtained after exercise. At implant, the S-ICD terminated ventricular fibrillation (VF) with a 65J shock in all 15 implanted patients and a 50J shock was successful in 12 of 15. A 35J shock terminated VF in 10 of 12 patients. DFT failure at 50 J was associated with a higher BMI. There were no appropriate shocks after a median follow-up of 17.5 (3-35) months, and 1 patient received an inappropriate shock attributable to a temporary reduction in QRS amplitude while bending forward, resulting in oversensing, despite successful screening. In a high-risk HCM cohort without a pacing indication referred for consideration of an ICD, the majority were eligible for S-ICD. The S-ICD is effective at recognizing and terminating VF at implant with a wide safety margin. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Gaba, Prakriti; Bos, J Martijn; Cannon, Bryan C; Cha, Yong-Mei; Friedman, Paul A; Asirvatham, Samuel J; Ackerman, Michael J
2016-04-01
Primary treatment of long QT syndrome (LQTS) currently consists of beta-blocker therapy, although an implantable cardioverter-defibrillator (ICD) is considered for high-risk patients. However, both overdiagnosis and overtreatment must be avoided because their sequelae can be significant. The purpose of this study was to evaluate the prevalence and details of ICD explants in a cohort of patients from a tertiary genetic heart rhythm clinic for a previously rendered diagnosis of LQTS. Overall, 1227 consecutive patients were included in the study. All patients had been referred to the Mayo Clinic for evaluation of possible LQTS and subsequently were either diagnosed with LQTS or dismissed as normal. Further stratification of patients was conducted to assess how many patients had an ICD and how many had a subsequent ICD explant. In total, 170 patients (14%) had an ICD, including 157 of 670 patients (23%) with confirmed LQTS and 13 of 557 patients (2%) who did not have LQTS. Among these, 12 of 1227 (1%) had the ICD removed: 7 of 157 LQTS patients (4.5%) compared to 5 of 14 non-LQTS patients (36%). Before explant, 5 of 12 patients (42%) experienced inappropriate shocks, ranging from 2 to as many as 54 shocks. In addition, 4 had a device-related infection, and 9 had device malfunction (including lead dysfunction or fracture). None of these patients had a breakthrough cardiac event since removal of their ICD during 5.5 ± 3.5 years of follow-up. Implications of overdiagnosis and overtreatment are profound because unnecessary ICD placement can be associated with infection, malfunction, inappropriate shocks, and subsequent anxiety. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Morken, Ingvild Margreta; Norekvål, Tone M; Isaksen, Kjetil; Munk, Peter S; Karlsen, Bjørg; Larsen, Alf I
2013-06-01
Research suggests that exercise training (ET) programmes may improve both physical and psychosocial functioning in implantable cardioverter defibrillator (ICD) recipients. Most of this research has been conducted by means of quantitative methods. However, knowledge of older ICD recipients' experiences of participating in such programmes is sparse. There is thus a need for more detailed qualitative data from the perspective of older patients. To describe older ICD recipients' experiences of participating in an ET programme. A qualitative design with semistructured interviews involving 12 older ICD recipients who had participated in a 3-month ET programme. Mini-disc recordings of the interviews were transcribed verbatim and analysed using content analysis. The analysis revealed two major themes: (1) 'increased confidence to engage in physical exertion'; and (2) 'increased satisfaction with life'. The first theme is illustrated by three subthemes: 'perceived support from physiotherapists', 'perceiving the heart rate monitor as a motivation to exercise', and 'perceiving peers as motivators for enjoyment and making the effort to exercise'. The second theme was illustrated by the following subthemes: 'perceived psychosocial benefits', 'perceived physical benefits', and 'exercise as a new health habit'. The findings indicate that exercising in a cardiac rehabilitation centre together with peers and supervised by skilled healthcare professionals may increase motivation to exert oneself, leading to emotional and physical benefits as well as a more social and active lifestyle for older ICD recipients.
Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica
2013-01-01
Background Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC ICD-9 codes, and evaluated whether natural language processing (NLP) by the Automated Retrieval Console (ARC) for document classification improves HCC identification. Methods We identified a cohort of patients with ICD-9 codes for HCC during 2005–2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared to manual classification. PPV, sensitivity, and specificity of ARC were calculated. Results 1138 patients with HCC were identified by ICD-9 codes. Based on manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. Conclusion A combined approach of ICD-9 codes and NLP of pathology and radiology reports improves HCC case identification in automated data. PMID:23929403
Sada, Yvonne; Hou, Jason; Richardson, Peter; El-Serag, Hashem; Davila, Jessica
2016-02-01
Accurate identification of hepatocellular cancer (HCC) cases from automated data is needed for efficient and valid quality improvement initiatives and research. We validated HCC International Classification of Diseases, 9th Revision (ICD-9) codes, and evaluated whether natural language processing by the Automated Retrieval Console (ARC) for document classification improves HCC identification. We identified a cohort of patients with ICD-9 codes for HCC during 2005-2010 from Veterans Affairs administrative data. Pathology and radiology reports were reviewed to confirm HCC. The positive predictive value (PPV), sensitivity, and specificity of ICD-9 codes were calculated. A split validation study of pathology and radiology reports was performed to develop and validate ARC algorithms. Reports were manually classified as diagnostic of HCC or not. ARC generated document classification algorithms using the Clinical Text Analysis and Knowledge Extraction System. ARC performance was compared with manual classification. PPV, sensitivity, and specificity of ARC were calculated. A total of 1138 patients with HCC were identified by ICD-9 codes. On the basis of manual review, 773 had HCC. The HCC ICD-9 code algorithm had a PPV of 0.67, sensitivity of 0.95, and specificity of 0.93. For a random subset of 619 patients, we identified 471 pathology reports for 323 patients and 943 radiology reports for 557 patients. The pathology ARC algorithm had PPV of 0.96, sensitivity of 0.96, and specificity of 0.97. The radiology ARC algorithm had PPV of 0.75, sensitivity of 0.94, and specificity of 0.68. A combined approach of ICD-9 codes and natural language processing of pathology and radiology reports improves HCC case identification in automated data.
Ross, Joseph S; Bates, Jonathan; Parzynski, Craig S; Akar, Joseph G; Curtis, Jeptha P; Desai, Nihar R; Freeman, James V; Gamble, Ginger M; Kuntz, Richard; Li, Shu-Xia; Marinac-Dabic, Danica; Masoudi, Frederick A; Normand, Sharon-Lise T; Ranasinghe, Isuru; Shaw, Richard E; Krumholz, Harlan M
2017-01-01
Machine learning methods may complement traditional analytic methods for medical device surveillance. Using data from the National Cardiovascular Data Registry for implantable cardioverter-defibrillators (ICDs) linked to Medicare administrative claims for longitudinal follow-up, we applied three statistical approaches to safety-signal detection for commonly used dual-chamber ICDs that used two propensity score (PS) models: one specified by subject-matter experts (PS-SME), and the other one by machine learning-based selection (PS-ML). The first approach used PS-SME and cumulative incidence (time-to-event), the second approach used PS-SME and cumulative risk (Data Extraction and Longitudinal Trend Analysis [DELTA]), and the third approach used PS-ML and cumulative risk (embedded feature selection). Safety-signal surveillance was conducted for eleven dual-chamber ICD models implanted at least 2,000 times over 3 years. Between 2006 and 2010, there were 71,948 Medicare fee-for-service beneficiaries who received dual-chamber ICDs. Cumulative device-specific unadjusted 3-year event rates varied for three surveyed safety signals: death from any cause, 12.8%-20.9%; nonfatal ICD-related adverse events, 19.3%-26.3%; and death from any cause or nonfatal ICD-related adverse event, 27.1%-37.6%. Agreement among safety signals detected/not detected between the time-to-event and DELTA approaches was 90.9% (360 of 396, k =0.068), between the time-to-event and embedded feature-selection approaches was 91.7% (363 of 396, k =-0.028), and between the DELTA and embedded feature selection approaches was 88.1% (349 of 396, k =-0.042). Three statistical approaches, including one machine learning method, identified important safety signals, but without exact agreement. Ensemble methods may be needed to detect all safety signals for further evaluation during medical device surveillance.
Daoud, Emile G; Kalbfleisch, Steven J; Hummel, John D; Weiss, Raul; Augustini, Ralph S; Duff, Steven B; Polsinelli, Georgia; Castor, John; Meta, Tejas
2002-10-01
The aim of this study is to describe implantation techniques and lead performance for biventricular pacing, dual-chamber implantable cardioverter defibrillators (ICDs). A dual-chamber ICD with biventricular pacing was implanted in 87 patients with congestive heart failure (ejection fraction: 0.21 +/- 0.09), prolonged QRS duration (161 +/- 22 msec), and an indication for ICD therapy. Left ventricular pacing was achieved with a thoracotomy approach (n = 21) or a nonthoracotomy approach (n = 66). With a thoracotomy, biventricular devices were implanted successfully in all patients. During follow-up (17 +/- 11 months), 9 patients died (43%), 2 underwent transplantation, and 2 required left ventricular lead revision. At last follow-up, biventricular sensing and capture threshold were 11 +/- 5 mV and 1.5 +/- 0.8 V, respectively. For nonthoracotomy procedures, two types of coronary sinus (CS) leads were implanted: an over-the-wire lead (n = 45) and a shaped lead (n = 21). The rate of successful implantation (overall: 89%) (over-the-wire 93% vs shaped 81%; P = 0.1) and durations for CS lead placement (66 +/- 50 vs 58 +/- 34 min, P = 0.6) and the procedure (133 +/- 58 vs 129 +/- 33 min, P = 0.8) were not different between the two CS leads. During follow-up (11 +/- 9 months), 9 patients died (14%), and the shaped CS lead dislodged in 3 patients (3 shaped vs 0 over-the-wire, P = 0.01). At last follow-up, biventricular sensing and capture threshold were 10 +/- 4 mV and 1.8 +/- 0.7 V, respectively, and there was no difference between over-the-wire and shaped leads. By multivariate analysis, mortality was associated with absence of spironolactone therapy but not procedural features. Nonthoracotomy CS lead implantation is feasible, with a success rate of about 90% and few adverse events. For the remaining 10%, a thoracotomy approach can be completed safely in these ill patients without increased risk for death.
Rao, Hygriv B; Saksena, Sanjeev
2005-08-01
Hybrid therapy strategies have combined antiarrhythmic drugs (AAD) with pacemakers, atrio-ventricular defibrillators (AV ICD) or atrial ablation individually. The feasibility combining AAD with dual site RA pacing (DAP) in an AV ICD has not been examined. We used an AV ICD with a novel lead configuration permitting DAP, antitachycardia pacing (ATP) or atrial shocks (ADF) in patients (pts) with refractory persistent or permanent AF. Hybrid therapy included linear RA ablation and/or focal ablation. Continuous DAP and automatic ATP with patient or physician activated ADF. 24 pts, mean age 66 +/- 10 yrs, with cardiac disease (22 pts), underwent insertion of an AVICD with dual RA leads. 20 patients had concomitant ablative procedures (RA only = 19, RA + LA = 1) and all pts continued previously ineffective AAD. During a follow-up of 2-36 months (mean 17 +/- 8 mos), rhythm control was restored in all pts & maintained long-term in 19 (83%) pts. 8 pts used AF termination therapies successfully. Device datalogs showed no episodes of AF in 6 pts, asymptomatic brief arrhythmias in 4 pts, infrequent paroxysmal AF in 9 pts & persistent AF recurred in 5 pts. AV ICD detection algorithms reliably detected AF or AT in the DAP mode in all pts. Intermittent brief P wave double counting occurred during AT in selected pts. No pt received inappropriate ADF therapy. 1. DAP can be safely incorporated in an AVICD devices for use in an hybrid therapy strategy for AF pts. 2. These devices can be effective for both AF prevention & termination. 3. Long term rhythm control can be achieved and documented by device datalogs in persistent and permanent AF.
NASA Astrophysics Data System (ADS)
Yang, C. H.; Kenduiywo, B. K.; Soergel, U.
2016-06-01
Persistent Scatterer Interferometry (PSI) is a technique to detect a network of extracted persistent scatterer (PS) points which feature temporal phase stability and strong radar signal throughout time-series of SAR images. The small surface deformations on such PS points are estimated. PSI particularly works well in monitoring human settlements because regular substructures of man-made objects give rise to large number of PS points. If such structures and/or substructures substantially alter or even vanish due to big change like construction, their PS points are discarded without additional explorations during standard PSI procedure. Such rejected points are called big change (BC) points. On the other hand, incoherent change detection (ICD) relies on local comparison of multi-temporal images (e.g. image difference, image ratio) to highlight scene modifications of larger size rather than detail level. However, image noise inevitably degrades ICD accuracy. We propose a change detection approach based on PSI to synergize benefits of PSI and ICD. PS points are extracted by PSI procedure. A local change index is introduced to quantify probability of a big change for each point. We propose an automatic thresholding method adopting change index to extract BC points along with a clue of the period they emerge. In the end, PS ad BC points are integrated into a change detection image. Our method is tested at a site located around north of Berlin main station where steady, demolished, and erected building substructures are successfully detected. The results are consistent with ground truth derived from time-series of aerial images provided by Google Earth. In addition, we apply our technique for traffic infrastructure, business district, and sports playground monitoring.
Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator.
Russo, Robert J; Costa, Heather S; Silva, Patricia D; Anderson, Jeffrey L; Arshad, Aysha; Biederman, Robert W W; Boyle, Noel G; Frabizzio, Jennifer V; Birgersdotter-Green, Ulrika; Higgins, Steven L; Lampert, Rachel; Machado, Christian E; Martin, Edward T; Rivard, Andrew L; Rubenstein, Jason C; Schaerf, Raymond H M; Schwartz, Jennifer D; Shah, Dipan J; Tomassoni, Gery F; Tominaga, Gail T; Tonkin, Allison E; Uretsky, Seth; Wolff, Steven D
2017-02-23
The presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverter-defibrillator (ICD) that was "non-MRI-conditional" (i.e., not approved by the Food and Drug Administration for MRI scanning). Patients in the registry were referred for clinically indicated nonthoracic MRI at a field strength of 1.5 tesla. Devices were interrogated before and after MRI with the use of a standardized protocol and were appropriately reprogrammed before the scanning. The primary end points were death, generator or lead failure, induced arrhythmia, loss of capture, or electrical reset during the scanning. The secondary end points were changes in device settings. MRI was performed in 1000 cases in which patients had a pacemaker and in 500 cases in which patients had an ICD. No deaths, lead failures, losses of capture, or ventricular arrhythmias occurred during MRI. One ICD generator could not be interrogated after MRI and required immediate replacement; the device had not been appropriately programmed per protocol before the MRI. We observed six cases of self-terminating atrial fibrillation or flutter and six cases of partial electrical reset. Changes in lead impedance, pacing threshold, battery voltage, and P-wave and R-wave amplitude exceeded prespecified thresholds in a small number of cases. Repeat MRI was not associated with an increase in adverse events. In this study, device or lead failure did not occur in any patient with a non-MRI-conditional pacemaker or ICD who underwent clinically indicated nonthoracic MRI at 1.5 tesla, was appropriately screened, and had the device reprogrammed in accordance with the prespecified protocol. (Funded by St. Jude Medical and others; MagnaSafe ClinicalTrials.gov number, NCT00907361 .).
Fauchier, Laurent; Alonso, Christine; Anselme, Frederic; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jerome; Piot, Olivier; Hanon, Olivier
2016-10-01
Despite the increasingly high rate of implantation of pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety and effectiveness of conventional pacing, ICDs and cardiac resynchronization therapy (CRT) in elderly patients. Although periprocedural risk may be slightly higher in the elderly, the implantation procedure for PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, the general consensus is that DDD pacing with the programming of an algorithm to minimize ventricular pacing is preferred. In very old patients presenting with intermittent or suspected atrioventricular block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is similar in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantageous effect of the device on arrhythmic death may be attenuated by higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live more than 5-7years after implantation. Elderly patients usually experience significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non-responders remains globally the same, while considering a less aggressive approach in terms of reinterventions (revision of left ventricular [LV] lead placement, addition of a right ventricular or LV lead, LV endocardial pacing configuration). Overall, physiological age, general status and comorbidities rather than chronological age per se should be the decisive factors in making a decision about device implantation selection for survival and well-being benefit in elderly patients. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Lalukota, Krishna; Cleland, John G F; Ingle, Lee; Clark, Andrew L; Coletta, Alison P
2004-12-01
This article summarises key presentations relevant to the pathophysiology, prevention or treatment of heart failure, from the Heart Failure Society of America annual meeting held in Toronto, Canada. Data from the EnoxiMone in intravenous inOTropE-dependent subjects (EMOTE) study suggest that the oral PDE-3 inhibitor enoximone may be effective for weaning severe heart failure patients from intravenous inotropic therapy. Hawthorn Extract Randomised Blinded Trial in CHF (HERB-CHF) failed to show a benefit of hawthorn extract added to conventional heart failure therapy. A genetic sub-group analysis of the Blocker Evaluation of Survival Trial (BEST) study showed that bucindolol reduced mortality and hospitalisations in patients who were homozygous for the Arg389 variant of the beta(1) adrenoceptor. In the Resynchronisation Hemodynamic Treatment for Heart Failure Management (RHYTHM-ICD) study, patients randomised to cardiac resynchronisation therapy (CRT) showed an improvement in symptoms and functional capacity compared to the control group.
Haghighi, Mohammad Hosein Hayavi; Dehghani, Mohammad; Teshnizi, Saeid Hoseini; Mahmoodi, Hamid
2014-01-01
Accurate cause of death coding leads to organised and usable death information but there are some factors that influence documentation on death certificates and therefore affect the coding. We reviewed the role of documentation errors on the accuracy of death coding at Shahid Mohammadi Hospital (SMH), Bandar Abbas, Iran. We studied the death certificates of all deceased patients in SMH from October 2010 to March 2011. Researchers determined and coded the underlying cause of death on the death certificates according to the guidelines issued by the World Health Organization in Volume 2 of the International Statistical Classification of Diseases and Health Related Problems-10th revision (ICD-10). Necessary ICD coding rules (such as the General Principle, Rules 1-3, the modification rules and other instructions about death coding) were applied to select the underlying cause of death on each certificate. Demographic details and documentation errors were then extracted. Data were analysed with descriptive statistics and chi square tests. The accuracy rate of causes of death coding was 51.7%, demonstrating a statistically significant relationship (p=.001) with major errors but not such a relationship with minor errors. Factors that result in poor quality of Cause of Death coding in SMH are lack of coder training, documentation errors and the undesirable structure of death certificates.
Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.
Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir
2014-02-01
Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P < 0.001). The 4-year survival rate of device battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P < 0.001). The difference in battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.
Cram, Peter; Katz, David; Vijan, Sandeep; Kent, David M; Langa, Kenneth M; Fendrick, A Mark
2006-01-01
Implantable cardioverter defibrillators (ICDs) are highly effective at preventing cardiac arrest, but their availability is limited by high cost. Automated external defibrillators (AEDs) are likely to be less effective, but also less expensive. We used decision analysis to evaluate the clinical and economic trade-offs of AEDs, ICDs, and emergency medical services equipped with defibrillators (EMS-D) for reducing cardiac arrest mortality. A Markov model was developed to compare the cost-effectiveness of three strategies in adults meeting entry criteria for the MADIT II Trial: strategy 1, individuals experiencing cardiac arrest are treated by EMS-D; strategy 2, individuals experiencing cardiac arrest are treated with an in-home AED; and strategy 3, individuals receive a prophylactic ICD. The model was then used to quantify the aggregate societal benefit of these three strategies under the conditions of a constrained federal budget. Compared with EMS-D, in-home AEDs produced a gain of 0.05 quality-adjusted life-years (QALYs) at an incremental cost of $5225 ($104,500 per QALY), while ICDs produced a gain of 0.90 QALYs at a cost of $114,660 ($127,400 per QALY). For every $1 million spent on defibrillators, 1.7 additional QALYs are produced by purchasing AEDs (9.6 QALYs/$million) instead of ICDs (7.9 QALYs/$million). Results were most sensitive to defibrillator complication rates and effectiveness, defibrillator cost, and adults' risk of cardiac arrest. Both AEDs and ICDs reduce cardiac arrest mortality, but AEDs are significantly less expensive and less effective. If financial constraints were to lead to rationing of defibrillators, it might be preferable to provide more people with a less effective and less expensive intervention (in-home AEDs) instead of providing fewer people with a more effective and more costly intervention (ICDs).
Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José
2017-02-01
Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P < 0.0001) and a trend to higher number of appropriate leads in right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P < 0.001). Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.
Gupta, Nigel; Kiley, Mary Lou; Anthony, Faith; Young, Charlie; Brar, Somjot; Kwaku, Kevin
2016-03-09
The purpose of this study is to describe key elements, clinical outcomes, and potential uses of the Kaiser Permanente-Cardiac Device Registry. This is a cohort study of implantable cardioverter defibrillators (ICD), pacemakers (PM), and cardiac resynchronization therapy (CRT) devices implanted between January 1, 2007 and December 31, 2013 by ≈400 physicians in 6 US geographical regions. Registry data variables, including patient characteristics, comorbidities, indication for procedures, complications, and revisions, were captured using the healthcare system's electronic medical record. Outcomes were identified using electronic screening algorithms and adjudicated via chart review. There were 11 924 ICDs, 33 519 PMs, 4472 CRTs, and 66 067 leads registered. A higher proportion of devices were implanted in males: 75.1% (ICD), 55.0% (PM), and 66.7% (CRT), with mean patient age 63.2 years (ICD), 75.2 (PM), and 67.2 (CRT). The 30-day postoperative incidence of tamponade, hematoma, and pneumothorax were ≤0.3% (ICD), ≤0.6% (PM), and ≤0.4% (CRT). Device failures requiring revision occurred at a rate of 2.17% for ICDs, 0.85% for PMs, and 4.93% for CRTs, per 100 patient observation years. Superficial infection rates were <0.03% for all devices; deep infection rates were 0.6% (ICD), 0.5% (PM), and 1.0% (CRT). Results were used to monitor vendor-specific variations and were systematically shared with individual regions to address potential variations in outcomes, utilization, and to assist with the management of device recalls. The Kaiser Permanente-Cardiac Device Registry is a robust tool to monitor postprocedural patient outcomes and postmarket surveillance of implants and potentially change practice patterns. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence
2016-05-01
Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Lampert, Rachel; Olshansky, Brian; Heidbuchel, Hein; Lawless, Christine; Saarel, Elizabeth; Ackerman, Michael; Calkins, Hugh; Estes, N A Mark; Link, Mark S; Maron, Barry J; Marcus, Frank; Scheinman, Melvin; Wilkoff, Bruce L; Zipes, Douglas P; Berul, Charles I; Cheng, Alan; Law, Ian; Loomis, Michele; Barth, Cheryl; Brandt, Cynthia; Dziura, James; Li, Fangyong; Cannom, David
2013-05-21
The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Athletes with ICDs (age, 10-60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21-46 months) follow-up, there were no occurrences of either primary end point-death or resuscitated arrest or arrhythmia- or shock-related injury-during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.
Guédon-Moreau, Laurence; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Brigadeau, François; Boulé, Stéphane; Blangy, Hugues; Lacroix, Dominique; Clémenty, Jacques; Sadoul, Nicolas; Kacet, Salem
2014-07-01
Inappropriate shocks remain a highly challenging complication of implantable cardioverter defibrillators (ICD). We examined whether automatic wireless remote monitoring (RM) of ICD, by providing early notifications of triggering events, lowers the incidence of inappropriate shocks. We studied 433 patients randomly assigned to RM (n = 221; active group) versus ambulatory follow-up (n = 212; control group). Patients in the active group were seen in the ambulatory department once a year, unless RM reported an event requiring an earlier ambulatory visit. Patients in the control group were seen in the ambulatory department every 6 months. The occurrence of first and further inappropriate shocks, and their causes in each group were compared. The characteristics of the study groups, including pharmaceutical regimens, were similar. Over a follow-up of 27 months, 5.0% of patients in the active group received ≥1 inappropriate shocks versus 10.4% in the control group (P = 0.03). A total of 28 inappropriate shocks were delivered in the active versus 283 in the control group. Shocks were triggered by supraventricular tachyarrhythmias (SVTA) in 48.5%, noise oversensing in 21.2%, T wave oversensing in 15.2%, and lead dysfunction in 15.2% of patients. The numbers of inappropriate shocks delivered per patient, triggered by SVTA and by lead dysfunction, were 74% and 98% lower, respectively, in the active than in the control group. RM was highly effective in the long-term prevention of inappropriate ICD shocks. © 2014 Wiley Periodicals, Inc.
Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J
2011-06-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines recommend EF <30% as a threshold for those with NYHA class I symptoms. The evidence is applicable to patients post CABG, provided all the other criteria are met. European Society of Cardiology (ESC) guidelines recommend waiting at least three months (consensus opinion) after revascularisation prior to assessment for an ICD, to allow time for potential recovery of ventricular function.
NASA Astrophysics Data System (ADS)
Vargas, E. L.; Rivas, D. A.; Duot, A. C.; Hovey, R. T.; Andrianarijaona, V. M.
2015-03-01
DNA replication is the basis for all biological reproduction. A strand of DNA will ``unzip'' and bind with a complimentary strand, creating two identical strands. In this study, we are considering how this process is affected by Interatomic Coulombic Decay (ICD), specifically how ICD affects the individual coding proteins' ability to hold together. ICD mainly deals with how the electron returns to its original state after excitation and how this affects its immediate atomic environment, sometimes affecting the connectivity between interaction sites on proteins involved in the DNA coding process. Biological heredity is fundamentally controlled by DNA and its replication therefore it affects every living thing. The small nature of the proteins (within the range of nanometers) makes it a good candidate for research of this scale. Understanding how ICD affects DNA molecules can give us invaluable insight into the human genetic code and the processes behind cell mutations that can lead to cancer. Authors wish to give special thanks to Pacific Union College Student Senate in Angwin, California, for their financial support.
DeWitt, Elizabeth S; Triedman, John K; Cecchin, Frank; Mah, Doug Y; Abrams, Dominic J; Walsh, Edward P; Gauvreau, Kimberlee; Alexander, Mark E
2014-12-01
Implantable cardioverter defibrillators (ICDs) used to prevent sudden cardiac arrest in children not only provide appropriate therapy in 25% of patients but also result in a significant incidence of inappropriate shocks and other device complications. ICDs placed for secondary prevention have higher rates of appropriate therapy than those placed for primary prevention. Pediatric patients with primary prevention ICDs were studied to determine time-dependent incidence of appropriate use and adverse events. A total of 140 patients aged <21 years (median age, 15 years) at first ICD implantation at Boston Children's Hospital (2000-2009) in whom devices were placed for primary prevention were retrospectively identified. Demographics and times to first appropriate shock; adverse events (including inappropriate shock, lead failure, reintervention, and complication); generator replacement and follow-up were noted. During mean follow-up of 4 years, appropriate shock occurred in 19% patients and first adverse event (excluding death/transplant) occurred in 36%. Risk of death or transplant was ≈1% per year and was not related to receiving appropriate therapy. Conditional survival analysis showed rates of appropriate therapy and adverse events decrease soon after implantation, but adverse events are more frequent than appropriate therapy throughout follow-up. Primary prevention ICDs were associated with appropriate therapy in 19% and adverse event in 36% in this cohort. The incidence of both first appropriate therapy and device-related adverse events decreased during longer periods of follow-up after implantation. This suggests that indications for continued device therapy in pediatric primary prevention ICD patients might be reconsidered after a period of nonuse. © 2014 American Heart Association, Inc.
Chang, Philip M; Powell, Brian D; Jones, Paul W; Carter, Nathan; Hayes, David L; Saxon, Leslie A
2016-10-01
Indications for implantable cardioverter defibrillators (ICDs) in young patients have expanded and differ from those in older adults. We sought to provide descriptive characteristics and data regarding ICD therapy and outcomes among younger and older ICD recipients. Demographics, device type and programming, remotely transmitted data, shock events, and survival were compared among younger (≤30 years) and older (>30 years) cohorts with ICDs from a single manufacturer followed on a remote network. The younger cohort included 904 patients (1.6% of all implants). This group had more females (46% vs. 25%; P < 0.01), single-coil leads (21% vs. 4%; P < 0.01), and single-chamber devices (46% vs. 34%; P < 0.01). Shock incidence was higher (40% younger vs. 32% older at 4 years; P < 0.01) and survival was better over comparable follow-up (88% vs. 72%; P < 0.01). Remote monitoring was associated with improved survival in both groups (93% vs. 86% ≤ 30 years, P < 0.01; 73% vs. 66% > 30 years, P < 0.01). Shock for polymorphic ventricular tachycardia/fibrillation (VT/VF) was more frequent in younger patients (12% vs. 5%; P < 0.01); 39% of all shocks were inappropriate. A 10-fold increased risk of mortality was seen among young patients with shocks for atrial fibrillation/flutter (AF/AFL). Differences in survival, shock incidence, and prognostic significance of VT/VF and AF/AFL exist between younger and older ICD recipients. These suggest distinct differences in myocardial substrates and diseases that ultimately impact ICD management. © 2016 Wiley Periodicals, Inc.
Makkar, Akash; Prisciandaro, Joann; Agarwal, Sunil; Lusk, Morgan; Horwood, Laura; Moran, Jean; Fox, Colleen; Hayman, James A; Ghanbari, Hamid; Roberts, Brett; Belardi, Diego; Latchamsetty, Rakesh; Crawford, Thomas; Good, Eric; Jongnarangsin, Krit; Bogun, Frank; Chugh, Aman; Oral, Hakan; Morady, Fred; Pelosi, Frank
2012-12-01
Radiation therapy's (RT's) effects on cardiac implantable electronic devices (CIEDs) such as implantable cardioverter-defibrillators (ICDs) and pacemakers (PMs) are not well established, leading to device removal or relocation in preparation for RT. To determine the effect of scattered RT on CIED performance. We analyzed 69 patients--50 (72%) with PMs and 19 (28%) with ICDs--receiving RT at the University of Michigan. Collected data included device model, anatomic location, and treatment beam energies, treatment type, and estimated dose to the device. Patients were treated with either high-energy (16-MV) and/or low-energy (6 MV) photon beams with or without electron beams (6-16 MeV). The devices were interrogated with pre- and post-RT and/or weekly with either in-treatment or home interrogation, depending on the patient's dependence on the device and the estimated or measured delivered dose. Outcomes analyzed were inappropriate ICD therapies, device malfunctions, or device-related clinical events. The PMs were exposed to 84.4 ± 99.7 cGy of radiation, and the ICDs were exposed to 92.1 ± 72.6 cGy of radiation. Two patients with ICDs experienced a partial reset of the ICD with the loss of historic diagnostic data after receiving 123 and 4 cGy, respectively. No device malfunction or premature battery depletion was observed at 6-month follow-up from RT completion. CIED malfunction due to indirect RT exposure is uncommon. Regular in-treatment or home interrogation should be done to detect and treat these events and to ensure that diagnostic data are preserved. Copyright © 2012 Elsevier Inc. All rights reserved.
Feasibility of early discharge after implantable cardioverter-defibrillator procedures.
Choudhuri, Indrajit; Desai, Dipan; Walburg, Jon; August, Phyllis; Keller, Seth I; Suri, Ranjit
2012-10-01
Registry data demonstrate considerably low complication rates after implantable cardioverter-defibrillator (ICD) procedures for primary prevention of sudden death. Yet standard of care includes postimplant overnight in-hospital observation that may levy substantial unnecessary financial burden on health care systems. In appropriate patients, discharge soon after implant could translate into significant cost savings, if such practice does not result in complications. We applied a simple clinical algorithm to assess feasibility of discharge on the same day of ICD implantation in patients at low risk for procedural complications. We prospectively randomized primary prevention ICD candidates at low risk for complications (not pacing-dependent or requiring bridging heparin anticoagulation) to next-day discharge with overnight in-hospital observation, or same-day discharge with remote monitoring for 24 hours after ICD implant. Implants were performed via cephalic vein access, and randomization occurred after 4-hours clinical observation and device interrogation. All patients were followed for a minimum of 6 weeks to assess acute procedural complications. 71 patients comprised the study cohort (mean age 62, 79% male) after 3 were excluded. The most common indication for ICD implant was ischemic cardiomyopathy with ejection fraction ≤35%. Device data obtained through 24-hour remote monitoring was comparable to 4-hour postimplant parameters in same-day discharge patients. No acute complications occurred in same-day discharge patients; 1 next-day discharge patient developed pneumothorax. ICD implantation with same-day discharge is reasonable in patients at low risk for complications. Remote monitoring can be useful in indicating lead-parameter stability during the immediate postoperative period. © 2012 Wiley Periodicals, Inc.
Ross, Joseph S; Bates, Jonathan; Parzynski, Craig S; Akar, Joseph G; Curtis, Jeptha P; Desai, Nihar R; Freeman, James V; Gamble, Ginger M; Kuntz, Richard; Li, Shu-Xia; Marinac-Dabic, Danica; Masoudi, Frederick A; Normand, Sharon-Lise T; Ranasinghe, Isuru; Shaw, Richard E; Krumholz, Harlan M
2017-01-01
Background Machine learning methods may complement traditional analytic methods for medical device surveillance. Methods and results Using data from the National Cardiovascular Data Registry for implantable cardioverter–defibrillators (ICDs) linked to Medicare administrative claims for longitudinal follow-up, we applied three statistical approaches to safety-signal detection for commonly used dual-chamber ICDs that used two propensity score (PS) models: one specified by subject-matter experts (PS-SME), and the other one by machine learning-based selection (PS-ML). The first approach used PS-SME and cumulative incidence (time-to-event), the second approach used PS-SME and cumulative risk (Data Extraction and Longitudinal Trend Analysis [DELTA]), and the third approach used PS-ML and cumulative risk (embedded feature selection). Safety-signal surveillance was conducted for eleven dual-chamber ICD models implanted at least 2,000 times over 3 years. Between 2006 and 2010, there were 71,948 Medicare fee-for-service beneficiaries who received dual-chamber ICDs. Cumulative device-specific unadjusted 3-year event rates varied for three surveyed safety signals: death from any cause, 12.8%–20.9%; nonfatal ICD-related adverse events, 19.3%–26.3%; and death from any cause or nonfatal ICD-related adverse event, 27.1%–37.6%. Agreement among safety signals detected/not detected between the time-to-event and DELTA approaches was 90.9% (360 of 396, k=0.068), between the time-to-event and embedded feature-selection approaches was 91.7% (363 of 396, k=−0.028), and between the DELTA and embedded feature selection approaches was 88.1% (349 of 396, k=−0.042). Conclusion Three statistical approaches, including one machine learning method, identified important safety signals, but without exact agreement. Ensemble methods may be needed to detect all safety signals for further evaluation during medical device surveillance. PMID:28860874
McQuilten, Z K; Zatta, A J; Andrianopoulos, N; Aoki, N; Stevenson, L; Badami, K G; Bird, R; Cole-Sinclair, M F; Hurn, C; Cameron, P A; Isbister, J P; Phillips, L E; Wood, E M
2017-04-01
To evaluate the use of routinely collected data to determine the cause(s) of critical bleeding in patients who receive massive transfusion (MT). Routinely collected data are increasingly being used to describe and evaluate transfusion practice. Chart reviews were undertaken on 10 randomly selected MT patients at 48 hospitals across Australia and New Zealand to determine the cause(s) of critical bleeding. Diagnosis-related group (DRG) and International Classification of Diseases (ICD) codes were extracted separately and used to assign each patient a cause of critical bleeding. These were compared against chart review using percentage agreement and kappa statistics. A total of 427 MT patients were included with complete ICD and DRG data for 427 (100%) and 396 (93%), respectively. Good overall agreement was found between chart review and ICD codes (78·3%; κ = 0·74, 95% CI 0·70-0·79) and only fair overall agreement with DRG (51%; κ = 0·45, 95% CI 0·40-0·50). Both ICD and DRG were sensitive and accurate for classifying obstetric haemorrhage patients (98% sensitivity and κ > 0·94). However, compared with the ICD algorithm, DRGs were less sensitive and accurate in classifying bleeding as a result of gastrointestinal haemorrhage (74% vs 8%; κ = 0·75 vs 0·1), trauma (92% vs 62%; κ = 0·78 vs 0·67), cardiac (80% vs 57%; κ = 0·79 vs 0·60) and vascular surgery (64% vs 56%; κ = 0·69 vs 0·65). Algorithms using ICD codes can determine the cause of critical bleeding in patients requiring MT with good to excellent agreement with clinical history. DRG are less suitable to determine critical bleeding causes. © 2016 British Blood Transfusion Society.
Choi, Y; Jung, C; Chae, Y; Kang, M; Kim, J; Joung, K; Lim, J; Cho, S; Sung, S; Lee, E; Kim, S
2014-01-01
Mapping of drug indications to ICD-10 was undertaken in Korea by a public and a private institution for their own purposes. A different mapping approach was used by each institution, which presented a good opportunity to compare the validity of the two approaches. This study was undertaken to compare the validity of a direct mapping approach and an indirect terminology based mapping approach of drug indications against the gold standard drawn from the results of the two mapping processes. Three hundred and seventy-five cardiovascular reference drugs were selected from all listed cardiovascular drugs for the study. In the direct approach, two experienced nurse coders mapped the free text indications directly to ICD-10. In the indirect terminology based approach, the indications were extracted and coded in the Korean Standard Terminology of Medicine. These terminology coded indications were then manually mapped to ICD-10. The results of the two approaches were compared to the gold standard. A kappa statistic was calculated to see the compatibility of both mapping approaches. Recall, precision and F1 score of each mapping approach were calculated and analyzed using a paired t-test. The mean number of indications for the study drugs was 5.42. The mean number of ICD-10 codes that matched in direct approach was 46.32 and that of indirect terminology based approach was 56.94. The agreement of the mapping results between the two approaches were poor (kappa = 0.19). The indirect terminology based approach showed higher recall (86.78%) than direct approach (p < 0.001). However, there was no difference in precision and F1 score between the two approaches. Considering no differences in the F1 scores, both approaches may be used in practice for mapping drug indications to ICD-10. However, in terms of consistency, time and manpower, better results are expected from the indirect terminology based approach.
Deep Learning for Automated Extraction of Primary Sites From Cancer Pathology Reports.
Qiu, John X; Yoon, Hong-Jun; Fearn, Paul A; Tourassi, Georgia D
2018-01-01
Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. In this study, we investigated deep learning and a convolutional neural network (CNN), for extracting ICD-O-3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations as the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro- and macro-F score increases of up to 0.132 and 0.226, respectively, when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on the CNN method and cancer site. These encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.
Sugrue, Alan; Killu, Ammar M; DeSimone, Christopher V; Chahal, Anwar A; Vogt, Josh C; Kremen, Vaclav; Hai, JoJo; Hodge, David O; Acker, Nancy G; Geske, Jeffrey B; Ackerman, Michael J; Ommen, Steve R; Lin, Grace; Noseworthy, Peter A; Brady, Peter A
2017-01-01
Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.
Akel, Tamer; Lafferty, James
2017-06-01
Implantable cardioverter defibrillators (ICDs) have proved their favorable outcomes on survival in selected patients with cardiomyopathy. Although previous meta-analyses have shown benefit for their use in primary prevention, the evidence remains less robust for patients with nonischemic cardiomyopathy (NICM) in comparison to patients with coronary artery disease (CAD). To evaluate the effect of ICD therapy on reducing all-cause mortality and sudden cardiac death (SCD) in patients with NICM. PubMed (1993-2016), the Cochrane Central Register of Controlled Trials (2000-2016), reference lists of relevant articles, and previous meta-analyses. Search terms included defibrillator, heart failure, cardiomyopathy, randomized controlled trials, and clinical trials. Eligible trials were randomized controlled trials with at least an arm of ICD, an arm of medical therapy and enrolled some patients with NICM. The primary endpoint in the trials should include all-cause mortality or mortality from SCD. Hazard ratios (HRs) for all-cause mortality and mortality from SCD were either extracted or calculated along with their standard errors. Of the 1047 abstracts retained by the initial screen, eight randomized controlled trials were identified. Five of these trials reported relevant data regarding patients with NICM and were subsequently included in this meta-analysis. Pooled analysis of HRs suggested a statistically significant reduction in all-cause mortality among a total of 2573 patients randomized to ICD vs medical therapy (HR 0.80; 95% CI, 0.67-0.96; P=.02). Pooled analysis of HRs for mortality from SCD was also statistically significant (n=1677) (HR 0.51; 95% CI, 0.34-0.76; P=.001). ICD implantation is beneficial in terms of all-cause mortality and mortality from SCD in certain subgroups of patients with NICM. © 2017 John Wiley & Sons Ltd.
Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui
2016-09-30
Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p < 0.001), but did not significantly affect mental component summary (MCS) scores (mean difference 0.84, 95 % CI -1.68 to 3.35, p = 0.52). Our meta-analysis demonstrates that psycho-educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.
Ock, Minsu; Kim, Hwa Jung; Jeon, Bomin; Kim, Ye-Jee; Ryu, Hyun Mi; Lee, Moo-Song
2018-01-01
The use of administrative data is an affordable alternative to conducting a difficult large-scale medical-record review to estimate the scale of adverse events. We identified adverse events from 2002 to 2013 on the national level in Korea, using International Classification of Diseases, tenth revision (ICD-10) Y codes. We used data from the National Health Insurance Service-National Sample Cohort (NHIS-NSC). We relied on medical treatment databases to extract information on ICD-10 Y codes from each participant in the NHIS-NSC. We classified adverse events in the ICD-10 Y codes into 6 types: those related to drugs, transfusions, and fluids; those related to vaccines and immunoglobulin; those related to surgery and procedures; those related to infections; those related to devices; and others. Over 12 years, a total of 20 817 adverse events were identified using ICD-10 Y codes, and the estimated total adverse event rate was 0.20%. Between 2002 and 2013, the total number of such events increased by 131.3%, from 1366 in 2002 to 3159 in 2013. The total rate increased by 103.9%, from 0.17% in 2002 to 0.35% in 2013. Events related to drugs, transfusions, and fluids were the most common (19 446, 93.4%), followed by those related to surgery and procedures (1209, 5.8%) and those related to vaccines and immunoglobulin (72, 0.3%). Based on a comparison with the results of other studies, the total adverse event rate in this study was significantly underestimated. Improving coding practices for ICD-10 Y codes is necessary to precisely monitor the scale of adverse events in Korea.
Blosnich, John R; Brown, George R; Wojcio, Sybil; Jones, Kenneth T; Bossarte, Robert M
2014-12-01
The aims of this project were to document all-cause and suicide mortality among Veteran Healthcare Administration (VHA) utilizers with The International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis consistent with transgender status. The study population consisted of VHA patients identified as having any one of four diagnosis codes indicating transgender status (n=5,117) gathered from the VA National Patient Care Database. Mortality data were gathered from the National Death Index from 2000-2009 for 1,277 veterans with transgender-related ICD-9-CM diagnoses. The remaining 3,840 were not searched because they had VHA utilization after 2009 (indicating they were alive). Person-time at risk (person-years) for crude rates were calculated based on the time from an individual's index diagnosis to either death or the end of FY 2009. Causes of death were categorized using ICD-10 code groups. Approximately 9.3% (n=309) veterans with transgender-related ICD-9-CM diagnoses died across the study period. Although diseases of the circulatory system and neoplasms were the first and second leading causes of death, respectively, the other ranked causes of mortality differed somewhat from patterns for the US during the same time span. The crude suicide rate among veterans with transgender-related ICD-9-CM diagnoses across the 10-year period was approximately 82/100,000 person-years, which approximated the crude suicide death rates for other serious mental illness in VHA (e.g., depression, schizophrenia). The average age of suicide decedents was 49.4 years. The crude suicide rate among veterans with transgender-related ICD-9-CM diagnoses is higher than in the general population, and they may be dying by suicide at younger ages than their veteran peers without transgender-related ICD-9-CM diagnoses. Future research, such as age-adjusted rates or accounting for psychiatric co-morbidities, will help to better clarify if the all-cause and suicide mortality rates are elevated for veterans with transgender-related ICD-9-CM diagnoses.
Using Chief Complaint in Addition to Diagnosis Codes to Identify Falls in the Emergency Department.
Patterson, Brian W; Smith, Maureen A; Repplinger, Michael D; Pulia, Michael S; Svenson, James E; Kim, Michael K; Shah, Manish N
2017-09-01
To compare incidence of falls in an emergency department (ED) cohort using a traditional International Classification of Diseases, Ninth Revision (ICD-9) code-based scheme and an expanded definition that included chief complaint information and to examine the clinical characteristics of visits "missed" in the ICD-9-based scheme. Retrospective electronic record review. Academic medical center ED. Individuals aged 65 and older seen in the ED between January 1, 2013, and September 30, 2015. Two fall definitions were applied (individually and together) to the cohort: an ICD-9-based definition and a chief complaint definition. Admission rates and 30-day mortality (per encounter) were measured for each definition. Twenty-three thousand eight hundred eighty older adult visits occurred during the study period. Using the most-inclusive definition (ICD-9 code or chief complaint indicating a fall), 4,363 visits (18%) were fall related. Of these visits, 3,506 (80%) met the ICD-9 definition for a fall-related visit, and 2,664 (61%) met the chief complaint definition. Of visits meeting the chief complaint definition, 857 (19.6%) were missed when applying the ICD-9 definition alone. Encounters missed using the ICD-9 definition were less likely to lead to an admission (42.9%, 95% confidence interval (CI) = 39.7-46.3%) than those identified (54.4%, 95% CI = 52.7-56.0%). Identifying individuals in the ED who have fallen based on diagnosis codes underestimates the true burden of falls. Individuals missed according to the code-based definition were less likely to have been admitted than those who were captured. These findings call attention to the value of using chief complaint information to identify individuals who have fallen in the ED-for research, clinical care, or policy reasons. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.
Patient satisfaction and suggestions for improvement of remote ICD monitoring.
Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe; Kensing, Finn; Svendsen, Jesper Hastrup
2012-09-01
The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients' wish for changes in remote follow-up routines. Four hundred seventy-four ICD patients at the device follow-up clinic at Rigshospitalet using CareLink® (Medtronic) remote follow-up, who had made ≥2 transmissions, received a questionnaire. Three hundred eighty-five patients (81.2%) answered. Mean time with ICD was 56 ± 45 months and mean age was 62 ± 13 years; 80% was male. Diagnosis related to ICD implant was: ischemic heart disease in 56% and dilated cardiomyopathy in 21%. Twenty-six percent had primary prophylactic indication. Mean time on remote FU was 16.4 ± 6.9 months. Mean time spent on in-clinic FU (two-way transport and FU) was 4 h and 36 min ± 7 h and 50 min, excluding 12 patients from Greenland and Faroe Islands. Ninety-five percent of the patients was very content or content with remote FU compared to in-clinic FU; 3% was less content and 2% was not content. For scheduled transmissions, 21% of the patients wished for a faster reply (sms or e-mail) compared to current practice with a letter. Eighty-four percent preferred more detailed information concerning ICD leads, battery status, and ICD therapies. A total of 96 patients (25%) had performed extra unscheduled remote transmissions: 20 due to shock, 20 due to alarm, 35 due to palpitations, and 18 for other or combined reasons. Ninety-five percent of the patients were content with the remote FU. Only 25% had unscheduled transmissions and most unscheduled transmissions were for appropriate reasons. Eighty-four percent of the patients wished for a more detailed response and 21% wished for a faster reply after routine transmissions.
Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M
2015-11-01
Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.
Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco
2015-05-01
Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Hedegaard, Holly; Schoenbaum, Michael; Claassen, Cynthia; Crosby, Alex; Holland, Kristin; Proescholdbell, Scott
2018-02-01
Suicide and intentional self-harm are among the leading causes of death in the United States. To study this public health issue, epidemiologists and researchers often analyze data coded using the International Classification of Diseases (ICD). Prior to October 1, 2015, health care organizations and providers used the clinical modification of the Ninth Revision of ICD (ICD-9-CM) to report medical information in electronic claims data. The transition in October 2015 to use of the clinical modification of the Tenth Revision of ICD (ICD-10-CM) resulted in the need to update methods and selection criteria previously developed for ICD-9-CM coded data. This report provides guidance on the use of ICD-10-CM codes to identify cases of nonfatal suicide attempts and intentional self-harm in ICD-10-CM coded data sets. ICD-10-CM codes for nonfatal suicide attempts and intentional self-harm include: X71-X83, intentional self-harm due to drowning and submersion, firearms, explosive or thermal material, sharp or blunt objects, jumping from a high place, jumping or lying in front of a moving object, crashing of motor vehicle, and other specified means; T36-T50 with a 6th character of 2 (except for T36.9, T37.9, T39.9, T41.4, T42.7, T43.9, T45.9, T47.9, and T49.9, which are included if the 5th character is 2), intentional self-harm due to drug poisoning (overdose); T51-T65 with a 6th character of 2 (except for T51.9, T52.9, T53.9, T54.9, T56.9, T57.9, T58.0, T58.1, T58.9, T59.9, T60.9, T61.0, T61.1, T61.9, T62.9, T63.9, T64.0, T64.8, and T65.9, which are included if the 5th character is 2), intentional self-harm due to toxic effects of nonmedicinal substances; T71 with a 6th character of 2, intentional self-harm due to asphyxiation, suffocation, strangulation; and T14.91, Suicide attempt. Issues to consider when selecting records for nonfatal suicide attempts and intentional self-harm from ICD-10-CM coded administrative data sets are also discussed. All material appearing in this report is in the public domain and may be reproduced or copied without permission; citation as to source, however, is appreciated.
Heart rate turbulence predicts ICD-resistant mortality in ischaemic heart disease.
Marynissen, Thomas; Floré, Vincent; Heidbuchel, Hein; Nuyens, Dieter; Ector, Joris; Willems, Rik
2014-07-01
In high-risk patients, implantable cardioverter-defibrillators (ICDs) can convert the mode of death from arrhythmic to pump failure death. Therefore, we introduced the concept of 'ICD-resistant mortality' (IRM), defined as death (a) without previous appropriate ICD intervention (AI), (b) within 1 month after the first AI, or (c) within 1 year after the initial ICD implantation. Implantable cardioverter-defibrillator implantation in patients with a high risk of IRM should be avoided. Implantable cardioverter-defibrillator patients with ischaemic heart disease were included if a digitized 24 h Holter was available pre-implantation. Demographic, electrocardiographic, echocardiographic, and 24 h Holter risk factors were collected at device implantation. The primary endpoint was IRM. Cox regression analyses were used to test the association between predictors and outcome. We included 130 patients, with a mean left ventricular ejection fraction (LVEF) of 33.6 ± 10.3%. During a follow-up of 52 ± 31 months, 33 patients died. There were 21 cases of IRM. Heart rate turbulence (HRT) was the only Holter parameter associated with IRM and total mortality. A higher New York Heart Association (NYHA) class and a lower body mass index were the strongest predictors of IRM. Left ventricular ejection fraction predicted IRM on univariate analysis, and was the strongest predictor of total mortality. The only parameter that predicted AI was non-sustained ventricular tachycardia. Implantable cardioverter-defibrillator implantation based on NYHA class and LVEF leads to selection of patients with a higher risk of IRM and death. Heart rate turbulence may have added value for the identification of poor candidates for ICD therapy. Available Holter parameters seem limited in their ability to predict AI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2013. For permissions please email: journals.permissions@oup.com.
Zusterzeel, Robbert; Caños, Daniel A; Sanders, William E; Silverman, Henry; MaCurdy, Thomas E; Worrall, Christopher M; Kelman, Jeffrey; Marinac-Dabic, Danica; Strauss, David G
2015-07-01
Previous analyses have shown that there is lower mortality with cardiac resynchronization therapy defibrillators (CRT-D) in patients with left bundle branch block (LBBB) but demonstrated mixed results in patients without LBBB. We evaluated the comparative effectiveness of CRT-D versus standard implantable defibrillators (ICDs) separately in patients with LBBB and right bundle branch block (RBBB) using Medicare claims data. Medicare records from CRT-D and ICD recipients from 2002 to 2009 that were followed up for up to 48 months were analyzed. We used propensity scores to match patients with ICD to those with CRT-D. In LBBB, 1:1 matching with replacement resulted in 54,218 patients with CRT-D and 20,763 with ICD, and in RBBB, 1:1 matching resulted in 7,298 patients with CRT-D and 7,298 with ICD. In LBBB, CRT-D had a 12% lower risk of heart failure hospitalization or death (hazard ratio [HR] 0.88, 95% confidence interval 0.86 to 0.90) and 5% lower death risk (HR 0.95, 0.92 to 0.97) compared with ICD. In RBBB, CRT-D had a 15% higher risk of heart failure hospitalization or death (HR 1.15, 1.10 to 1.20) and 13% higher death risk (HR 1.13, 1.07 to 1.18). Sensitivity analysis revealed that accounting for covariates not captured in the Medicare database may lead to increased benefit with CRT-D in LBBB and no difference in RBBB. In conclusion, in a large Medicare population, CRT-D was associated with lower mortality in LBBB but higher mortality in RBBB. The absence of certain covariates, in particular those that determine treatment selection, may affect the results of comparative effectiveness studies using claims data. Published by Elsevier Inc.
Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R
2015-03-01
Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P < .0001). Patients implanted in phase II had a lower risk of all-cause shock (adjusted hazard ratio 0.72, 95% confidence interval 0.58-0.90, P = .003). Providing programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Arias, Sarah A; Boudreaux, Edwin D; Chen, Elizabeth; Miller, Ivan; Camargo, Carlos A; Jones, Richard N; Uebelacker, Lisa
2018-05-23
In an emergency department (ED) sample, we investigated the concordance between identification of suicide-related visits through standardized comprehensive chart review versus a subset of three specific chart elements: ICD-9-CM codes, free-text presenting complaints, and free-text physician discharge diagnoses. Review of medical records for adults (≥18 years) at eight EDs across the United States. A total of 3,776 charts were reviewed. A combination of the three chart elements (ICD-9-CM, presenting complaints, and discharge diagnoses) provided the most robust data with 85% sensitivity, 96% specificity, 92% PPV, and 92% NPV. These findings highlight the use of key discrete fields in the medical record that can be extracted to facilitate identification of whether an ED visit was suicide-related.
Enhanced production of low energy electrons by alpha particle impact
Kim, Hong-Keun; Titze, Jasmin; Schöffler, Markus; Trinter, Florian; Waitz, Markus; Voigtsberger, Jörg; Sann, Hendrik; Meckel, Moritz; Stuck, Christian; Lenz, Ute; Odenweller, Matthias; Neumann, Nadine; Schössler, Sven; Ullmann-Pfleger, Klaus; Ulrich, Birte; Fraga, Rui Costa; Petridis, Nikos; Metz, Daniel; Jung, Annika; Grisenti, Robert; Czasch, Achim; Jagutzki, Ottmar; Schmidt, Lothar; Jahnke, Till; Schmidt-Böcking, Horst; Dörner, Reinhard
2011-01-01
Radiation damage to living tissue stems not only from primary ionizing particles but to a substantial fraction from the dissociative attachment of secondary electrons with energies below the ionization threshold. We show that the emission yield of those low energy electrons increases dramatically in ion–atom collisions depending on whether or not the target atoms are isolated or embedded in an environment. Only when the atom that has been ionized and excited by the primary particle impact is in immediate proximity of another atom is a fragmentation route known as interatomic Coulombic decay (ICD) enabled. This leads to the emission of a low energy electron. Over the past decade ICD was explored in several experiments following photoionization. Most recent results show its observation even in water clusters. Here we show the quantitative role of ICD for the production of low energy electrons by ion impact, thus approaching a scenario closer to that of radiation damage by alpha particles: We choose ion energies on the maximum of the Bragg peak where energy is most efficiently deposited in tissue. We compare the electron production after colliding He+ ions on isolated Ne atoms and on Ne dimers (Ne2). In the latter case the Ne atom impacted is surrounded by a most simple environment already opening ICD as a deexcitation channel. As a consequence, we find a dramatically enhanced low energy electron yield. The results suggest that ICD may have a significant influence on cell survival after exposure to ionizing radiation. PMID:21730184
Clinical implications of the proposed ICD-11 PTSD diagnostic criteria.
Barbano, Anna C; van der Mei, Willem F; Bryant, Richard A; Delahanty, Douglas L; deRoon-Cassini, Terri A; Matsuoka, Yutaka J; Olff, Miranda; Qi, Wei; Ratanatharathorn, Andrew; Schnyder, Ulrich; Seedat, Soraya; Kessler, Ronald C; Koenen, Karestan C; Shalev, Arieh Y
2018-05-14
Projected changes to post-traumatic stress disorder (PTSD) diagnostic criteria in the upcoming International Classification of Diseases (ICD)-11 may affect the prevalence and severity of identified cases. This study examined differences in rates, severity, and overlap of diagnoses using ICD-10 and ICD-11 PTSD diagnostic criteria during consecutive assessments of recent survivors of traumatic events. The study sample comprised 3863 survivors of traumatic events, evaluated in 11 longitudinal studies of PTSD. ICD-10 and ICD-11 diagnostic rules were applied to the Clinician-Administered PTSD Scale (CAPS) to derive ICD-10 and ICD-11 diagnoses at different time intervals between trauma occurrence and 15 months. The ICD-11 criteria identified fewer cases than the ICD-10 across assessment intervals (range -47.09% to -57.14%). Over 97% of ICD-11 PTSD cases met concurrent ICD-10 PTSD criteria. PTSD symptom severity of individuals identified by the ICD-11 criteria (CAPS total scores) was 31.38-36.49% higher than those identified by ICD-10 criteria alone. The latter, however, had CAPS scores indicative of moderate PTSD. ICD-11 was associated with similar or higher rates of comorbid mood and anxiety disorders. Individuals identified by either ICD-10 or ICD-11 shortly after traumatic events had similar longitudinal course. This study indicates that significantly fewer individuals would be diagnosed with PTSD using the proposed ICD-11 criteria. Though ICD-11 criteria identify more severe cases, those meeting ICD-10 but not ICD-11 criteria remain in the moderate range of PTSD symptoms. Use of ICD-11 criteria will have critical implications for case identification in clinical practice, national reporting, and research.
Mordovsky, E A; Soloviev, A G; Sannikov, A L
2015-01-01
To reveal the specific features of marital status and educational level in people who have died of leading circulatory diseases (CDs) in Arkhangelsk in relation to the place of death, alcohol anamnesis, and demographic characteristics (gender, life span). Materials and methods. Data on the diagnosed underlying cause of death, marital status, educational level, and place of death were copied from 4137 medical death certificates (form 106/y-08) of all those who had died in Arkhangelsk in 1 July to 30 June 2012. Data on patients registered at a psychoneurology dispensary as having a diagnosis of alcohol-induced mental and behavioral disorders (F10) were copied. The data were statistically processed using the procedures of binary and multinomial logistic regression analysis. A total of 2101 people (50.8% of the total number of deaths) died of CDs (ICD-10 Class IX) in the study period. Male sex and a compromised alcohol anamnesis were associated with untimely death (less than 60 years of age) from acute conditions in ICD-10 Class IX. Male sex, a compromised alcohol anamnesis, and negative characteristics of marital and educational statuses were related to untimely death from chronic conditions in ICD-10 Class IX. Single people having a lower educational level and a compromised alcohol anamnesis statistically more frequently died of CDs outside a health care facility. The results of the investigation suggest that there is inequality in the excess risk of death from leading CDs among the representatives of different social population groups in Arkhangelsk, as well as nonequivalence in their interaction with the public health system.
TRENCADIS--a WSRF grid MiddleWare for managing DICOM structured reporting objects.
Blanquer, Ignacio; Hernandez, Vicente; Segrelles, Damià
2006-01-01
The adoption of the digital processing of medical data, especially on radiology, has leaded to the availability of millions of records (images and reports). However, this information is mainly used at patient level, being the extraction of information, organised according to administrative criteria, which make the extraction of knowledge difficult. Moreover, legal constraints make the direct integration of information systems complex or even impossible. On the other side, the widespread of the DICOM format has leaded to the inclusion of other information different from just radiological images. The possibility of coding radiology reports in a structured form, adding semantic information about the data contained in the DICOM objects, eases the process of structuring images according to content. DICOM Structured Reporting (DICOM-SR) is a specification of tags and sections to code and integrate radiology reports, with seamless references to findings and regions of interests of the associated images, movies, waveforms, signals, etc. The work presented in this paper aims at developing of a framework to efficiently and securely share medical images and radiology reports, as well as to provide high throughput processing services. This system is based on a previously developed architecture in the framework of the TRENCADIS project, and uses other components such as the security system and the Grid processing service developed in previous activities. The work presented here introduces a semantic structuring and an ontology framework, to organise medical images considering standard terminology and disease coding formats (SNOMED, ICD9, LOINC..).
Bhatia, Atul; Cooley, Ryan; Berger, Marcie; Blanck, Zalmen; Dhala, Anwer; Sra, Jasbir; Axtell-Mcbride, Kathleen; Vandervort, Cheryl; Akhtar, Masood
2004-06-01
Since the introduction of the implantable cardioverter defibrillator (ICD) for the management of patients with high risk of arrhythmic SCD, there has been increasing use of this device. Its basic promise to effectively terminate ventricular tachycardia (VT)-ventricular fibrillation (VF) has been repeatedly met. In several randomized trials, the ICD has been shown to be superior to conventional anti-arrhythmic therapy, both in patients with documented VT-VF (secondary prevention) and those with high risk such as left ventricular ejection fraction and no prior sustained VT-VF (primary prevention). In both groups, the ICD showed overall and cardiac mortality reduction. The device now can more accurately detect VT-VF and differentiate these from other arrhythmias through a series of algorithms and direct-chamber sensing. Therapy options include painless antitachycardia pacing, low-energy cardioversion, and high-energy defibrillation. The technique implant is now simple as a pacemaker with one lead attached to an active (hot) can functioning as the other electrode. Among other improvements is its weight, volume, multiprogrammability, and storage of information,dual-chamber pacing and sensing, dual-chamber defibrillation, and addition of biventricular pacing for cardiac synchronization. It is anticipated that further improvement in ICD technology will take place and the list of indications will grow.
Interatomic Coulombic decay cascades in multiply excited neon clusters
Nagaya, K.; Iablonskyi, D.; Golubev, N. V.; Matsunami, K.; Fukuzawa, H.; Motomura, K.; Nishiyama, T.; Sakai, T.; Tachibana, T.; Mondal, S.; Wada, S.; Prince, K. C.; Callegari, C.; Miron, C.; Saito, N.; Yabashi, M.; Demekhin, Ph. V.; Cederbaum, L. S.; Kuleff, A. I.; Yao, M.; Ueda, K.
2016-01-01
In high-intensity laser light, matter can be ionized by direct multiphoton absorption even at photon energies below the ionization threshold. However on tuning the laser to the lowest resonant transition, the system becomes multiply excited, and more efficient, indirect ionization pathways become operative. These mechanisms are known as interatomic Coulombic decay (ICD), where one of the species de-excites to its ground state, transferring its energy to ionize another excited species. Here we show that on tuning to a higher resonant transition, a previously unknown type of interatomic Coulombic decay, intra-Rydberg ICD occurs. In it, de-excitation of an atom to a close-lying Rydberg state leads to electron emission from another neighbouring Rydberg atom. Moreover, systems multiply excited to higher Rydberg states will decay by a cascade of such processes, producing even more ions. The intra-Rydberg ICD and cascades are expected to be ubiquitous in weakly-bound systems exposed to high-intensity resonant radiation. PMID:27917867
Direct evidence of two interatomic relaxation mechanisms in argon dimers ionized by electron impact
Ren, Xueguang; Jabbour Al Maalouf, Elias; Dorn, Alexander; Denifl, Stephan
2016-01-01
In weakly bound systems like liquids and clusters electronically excited states can relax in inter-particle reactions via the interplay of electronic and nuclear dynamics. Here we report on the identification of two prominent examples, interatomic Coulombic decay (ICD) and radiative charge transfer (RCT), which are induced in argon dimers by electron collisions. After initial ionization of one dimer constituent ICD and RCT lead to the ionization of its neighbour either by energy transfer to or by electron transfer from the neighbour, respectively. By full quintuple-coincidence measurements, we unambiguously identify ICD and RCT, and trace the relaxation dynamics as function of the collisional excited state energies. Such interatomic processes multiply the number of electrons and shift their energies down to the critical 1–10 eV range, which can efficiently cause chemical degradation of biomolecules. Therefore, the observed relaxation channels might contribute to cause efficient radiation damage in biological systems. PMID:27000407
Nishii, Nobuhiro; Miyoshi, Akihito; Kubo, Motoki; Miyamoto, Masakazu; Morimoto, Yoshimasa; Kawada, Satoshi; Nakagawa, Koji; Watanabe, Atsuyuki; Nakamura, Kazufumi; Morita, Hiroshi; Ito, Hiroshi
2018-03-01
Remote monitoring (RM) has been advocated as the new standard of care for patients with cardiovascular implantable electronic devices (CIEDs). RM has allowed the early detection of adverse clinical events, such as arrhythmia, lead failure, and battery depletion. However, lead failure was often identified only by arrhythmic events, but not impedance abnormalities. To compare the usefulness of arrhythmic events with conventional impedance abnormalities for identifying lead failure in CIED patients followed by RM. CIED patients in 12 hospitals have been followed by the RM center in Okayama University Hospital. All transmitted data have been analyzed and summarized. From April 2009 to March 2016, 1,873 patients have been followed by the RM center. During the mean follow-up period of 775 days, 42 lead failure events (atrial lead 22, right ventricular pacemaker lead 5, implantable cardioverter defibrillator [ICD] lead 15) were detected. The proportion of lead failures detected only by arrhythmic events, which were not detected by conventional impedance abnormalities, was significantly higher than that detected by impedance abnormalities (arrhythmic event 76.2%, 95% CI: 60.5-87.9%; impedance abnormalities 23.8%, 95% CI: 12.1-39.5%). Twenty-seven events (64.7%) were detected without any alert. Of 15 patients with ICD lead failure, none has experienced inappropriate therapy. RM can detect lead failure earlier, before clinical adverse events. However, CIEDs often diagnose lead failure as just arrhythmic events without any warning. Thus, to detect lead failure earlier, careful human analysis of arrhythmic events is useful. © 2017 Wiley Periodicals, Inc.
Kutyifa, Valentina; Daubert, James P; Schuger, Claudio; Goldenberg, Ilan; Klein, Helmut; Aktas, Mehmet K; McNitt, Scott; Stockburger, Martin; Merkely, Bela; Zareba, Wojciech; Moss, Arthur J
2016-01-01
The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25-0.57; P<0.001). High-rate cut-off or delayed ventricular tachycardia therapy programming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; P<0.001 for all). There was a significant reduction in inappropriate anti-tachycardia pacings in both group and a significant reduction in inappropriate ICD shock in CRT-D patients. Patients implanted with a CRT-D have lower risk of inappropriate ICD therapy than those with an ICD. Innovative ICD programming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. http://clinicaltrials.gov; Unique identifier: NCT00947310. © 2016 American Heart Association, Inc.
Demoly, P; Tanno, L K; Akdis, C A; Lau, S; Calderon, M A; Santos, A F; Sanchez-Borges, M; Rosenwasser, L J; Pawankar, R; Papadopoulos, N G
2014-05-01
Hypersensitivity diseases are not adequately coded in the International Coding of Diseases (ICD)-10 resulting in misclassification, leading to low visibility of these conditions and general accuracy of official statistics. To call attention to the inadequacy of the ICD-10 in relation to allergic and hypersensitivity diseases and to contribute to improvements to be made in the forthcoming revision of ICD, a web-based global survey of healthcare professionals' attitudes toward allergic disorders classification was proposed to the members of European Academy of Allergy and Clinical Immunology (EAACI) (individuals) and World Allergy Organization (WAO) (representative responding on behalf of the national society), launched via internet and circulated for 6 week. As a result, we had 612 members of 144 countries from all six World Health Organization (WHO) global regions who answered the survey. ICD-10 is the most used classification worldwide, but it was not considered appropriate in clinical practice by the majority of participants. The majority indicated the EAACI-WAO classification as being easier and more accurate in the daily practice. They saw the need for a diagnostic system useful for nonallergists and endorsed the possibility of a global, cross-culturally applicable classification system of allergic disorders. This first and most broadly international survey ever conducted of health professionals' attitudes toward allergic disorders classification supports the need to update the current classifications of allergic diseases and can be useful to the WHO in improving the clinical utility of the classification and its global acceptability for the revised ICD-11. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
[The Wearable Cardioverter-Defibrillator (WCD)].
Helms, Thomas M; Müller, A; Schwab, J O; Bänsch, D; Karle, C; Klingenheben, T; Zugck, C; Perings, C
2015-06-01
While the implantable cardioverter-defibrillator (ICD) has been proven to be the best choice for patients with long-term risk for sudden cardiac arrest/sudden cardiac death (SCA/SCD), the question is how to manage patients with only temporary risk, e.g., during the guidelines-recommended waiting period until the decision for an ICD can be made. These patient groups should be monitored around the clock to guarantee a lifesaving shock within a few minutes, if necessary.These conditions can be accomplished by the wearable cardioverter-defibrillator (WCD) in the outpatient sector. The WCD is worn on the skin and consists of four nonadhesive ECG electrodes as well as three defibrillation electrodes-two at the back and one at the front-embedded in a garment. The defibrillation unit is connected via a cord and can be worn over the shoulder or on a belt. Cardiac events can be recorded and retrospectively analyzed by the treating physician.The WCD is a safe and effective measure to terminate potentially lethal ventricular tachycardia and ventricular fibrillation. It may be used early after myocardial infarction with reduced left ventricular ejection fraction (LVEF), as well as for patients with acute heart failure in nonischemic cardiomyopathy with uncertain cause and prognosis. In addition, it may be used for patients waiting for heart transplantation, for patients who cannot be implanted an ICD due to comorbidities, and for patients after explantation of their ICD, e.g., because of infection until reimplantation.One may expect that risk stratification of patients with the WCD will lead to even better selection for ICD use.
Shock anxiety among implantable cardioverter defibrillator recipients with recent tachyarrhythmia.
Morken, Ingvild M; Isaksen, Kjetil; Karlsen, Bjørg; Norekvål, Tone M; Bru, Edvin; Larsen, Alf Inge
2012-11-01
Shock anxiety has been documented irrespective of shock exposure in implantable cardioverter defibrillator (ICD) recipients. The presence of tachyarrhythmia may lead to an anticipation of receiving a shock and thereby give rise to shock anxiety. The aims were to assess: (1) the level of shock anxiety in a sample of ICD recipients, (2) the relationship between such anxiety and shock exposure, and (3) the relationship between recent tachyarrhythmia and shock anxiety. ICD recipients (n = 167) completed the Florida Shock Anxiety Scale measure of shock anxiety. The recipients were divided into three groups: (1) Recipients with no documented tachyarrhythmia over the previous 12 months (n = 56), (2) recipients with documented tachyarrhythmia over the previous twelve months (n = 54), and (3) recipients with any history of shocks (n = 57). Of the recipients, 44% experienced some form of shock anxiety, whereas 15% reported general shock anxiety. Analyses of covariance revealed that recipients with recent tachyarrhythmia (F = 7.675 df = 9/100, P = 0.007) as well as recipients with a shock history (F = 9.976, df = 9/103, P = 0.002) reported higher levels of shock anxiety than recipients with no recent tachyarrhythmia. This study indicates that although a substantial proportion of the ICD recipients experienced some form of shock anxiety, only a relatively small proportion reported general shock anxiety. ICD recipients with recent tachyarrhythmia, in addition to recipients with shock history, appear to be at greater risk for development of shock anxiety. This implies that these recipients may profit from clinical-based strategies and interventions targeting shock anxiety. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Luyckx, Kim; Luyten, Léon; Daelemans, Walter; Van den Bulcke, Tim
2016-01-01
Objective Enormous amounts of healthcare data are becoming increasingly accessible through the large-scale adoption of electronic health records. In this work, structured and unstructured (textual) data are combined to assign clinical diagnostic and procedural codes (specifically ICD-9-CM) to patient stays. We investigate whether integrating these heterogeneous data types improves prediction strength compared to using the data types in isolation. Methods Two separate data integration approaches were evaluated. Early data integration combines features of several sources within a single model, and late data integration learns a separate model per data source and combines these predictions with a meta-learner. This is evaluated on data sources and clinical codes from a broad set of medical specialties. Results When compared with the best individual prediction source, late data integration leads to improvements in predictive power (eg, overall F-measure increased from 30.6% to 38.3% for International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnostic codes), while early data integration is less consistent. The predictive strength strongly differs between medical specialties, both for ICD-9-CM diagnostic and procedural codes. Discussion Structured data provides complementary information to unstructured data (and vice versa) for predicting ICD-9-CM codes. This can be captured most effectively by the proposed late data integration approach. Conclusions We demonstrated that models using multiple electronic health record data sources systematically outperform models using data sources in isolation in the task of predicting ICD-9-CM codes over a broad range of medical specialties. PMID:26316458
Hayat, Sajad A; Kojodjojo, Pipin; Mason, Anthony; Benfield, Ann; Wright, Ian; Whinnett, Zachary; Lim, Phang Boon; Davies, D Wyn; Lefroy, David; Peters, Nicholas S; Kanagaratnam, Prapa
2013-03-01
Implantable cardioverter defibrillator (ICD) implantation has increased significantly over the last 10 years. Concerns about the safety and reliability of ICD systems have been raised, with premature lead failure and battery malfunctions accounting for the majority of reported adverse events. We describe the unique mode of presentation, diagnosis, and management of cardiac resynchronization therapy defibrillators (CRT-D) malfunctions that were caused by weakened bonding between the generator and header. Between June 2008 and December 2009, 22 Teligen™ ICDs and 24 Cognis™ CRT-Ds were implanted subpectorally at our institution, until a product advisory was issued. Of 24 Cognis™ CRT-D implants, 3 patients presented with CRT-D malfunctions. All our cases presented with initially intermittent and then persisting increases in shock lead impedance, associated with nonphysiological noise in the shock electrogram channels. These issues were rectified by generator change. Postexplant laboratory analysis confirmed inadequate bonding between device header and titanium casing in all cases, resulting in loosening and rocking of the header followed by fatigue-induced fracture of the shock circuitry. Weakened bonding between the header and generator casing of subpectorally implanted CRT-Ds can result in fractures and malfunction of the HV circuit. Physicians monitoring patients with devices affected by the product advisory should remain vigilant in order to diagnose and manage similar device malfunction expediently. © 2012 Wiley Periodicals, Inc.
Jetté, Nathalie; Quan, Hude; Hemmelgarn, Brenda; Drosler, Saskia; Maass, Christina; Moskal, Lori; Paoin, Wansa; Sundararajan, Vijaya; Gao, Song; Jakob, Robert; Ustün, Bedihran; Ghali, William A
2010-12-01
The United States is about to make a major nationwide transition from ICD-9-CM coding of hospital discharges to ICD-10-CM, a country-specific modification of the World Health Organization's ICD-10. As this transition occurs, the WHO is already in the midst of developing ICD-11. Given this context, we undertook this review to discuss: (1) the history of the International Classification of Diseases (a core information "building block" for health systems everywhere) from its introduction to the current era of ICD-11 development; (2) differences across country-specific ICD-10 clinical modifications and the challenges that these differences pose to the international comparability of morbidity data; (3) potential strategic approaches to achieving better international ICD-11 comparability. A literature review and stakeholder consultation was carried out. The various ICD-10 clinical modifications (ICD-10-AM [Australia], ICD-10-CA [Canada], ICD-10-GM [Germany], ICD-10-TM [Thailand], ICD-10-CM [United States]) were compared. These ICD-10 modifications differ in their number of codes, chapters, and subcategories. Specific conditions are present in some but not all of the modifications. ICD-11, with a similar structure to ICD-10, will function in an electronic health records environment and also provide disease descriptive characteristics (eg, causal properties, functional impact, and treatment). The threat to the comparability of international clinical morbidity is growing with the development of many country-specific ICD-10 versions. One solution to this threat is to develop a meta-database including all country-specific modifications to ensure more efficient use of people and resources, decrease omissions and errors but most importantly provide a platform for future ICD updates.
Conducting Retrospective Ontological Clinical Trials in ICD-9-CM in the Age of ICD-10-CM.
Venepalli, Neeta K; Shergill, Ardaman; Dorestani, Parvaneh; Boyd, Andrew D
2014-01-01
To quantify the impact of International Classification of Disease 10th Revision Clinical Modification (ICD-10-CM) transition in cancer clinical trials by comparing coding accuracy and data discontinuity in backward ICD-10-CM to ICD-9-CM mapping via two tools, and to develop a standard ICD-9-CM and ICD-10-CM bridging methodology for retrospective analyses. While the transition to ICD-10-CM has been delayed until October 2015, its impact on cancer-related studies utilizing ICD-9-CM diagnoses has been inadequately explored. Three high impact journals with broad national and international readerships were reviewed for cancer-related studies utilizing ICD-9-CM diagnoses codes in study design, methods, or results. Forward ICD-9-CM to ICD-10-CM mapping was performing using a translational methodology with the Motif web portal ICD-9-CM conversion tool. Backward mapping from ICD-10-CM to ICD-9-CM was performed using both Centers for Medicare and Medicaid Services (CMS) general equivalence mappings (GEMs) files and the Motif web portal tool. Generated ICD-9-CM codes were compared with the original ICD-9-CM codes to assess data accuracy and discontinuity. While both methods yielded additional ICD-9-CM codes, the CMS GEMs method provided incomplete coverage with 16 of the original ICD-9-CM codes missing, whereas the Motif web portal method provided complete coverage. Of these 16 codes, 12 ICD-9-CM codes were present in 2010 Illinois Medicaid data, and accounted for 0.52% of patient encounters and 0.35% of total Medicaid reimbursements. Extraneous ICD-9-CM codes from both methods (Centers for Medicare and Medicaid Services general equivalent mapping [CMS GEMs, n = 161; Motif web portal, n = 246]) in excess of original ICD-9-CM codes accounted for 2.1% and 2.3% of total patient encounters and 3.4% and 4.1% of total Medicaid reimbursements from the 2010 Illinois Medicare database. Longitudinal data analyses post-ICD-10-CM transition will require backward ICD-10-CM to ICD-9-CM coding, and data comparison for accuracy. Researchers must be aware that all methods for backward coding are not comparable in yielding original ICD-9-CM codes. The mandated delay is an opportunity for organizations to better understand areas of financial risk with regards to data management via backward coding. Our methodology is relevant for all healthcare-related coding data, and can be replicated by organizations as a strategy to mitigate financial risk.
Brugada Syndrome. Clinical, Genetic, Molecular, Cellular and Ionic Aspects
Antzelevitch, Charles; Patocskai, Bence
2015-01-01
The Brugada syndrome (BrS) is an inherited cardiac arrhythmia syndrome first described as a new clinical entity in 1992. Electrocardiographically characterized by distinct coved type ST segment elevation in the right precordial leads, the syndrome is associated with a high risk for sudden cardiac death in young adults, and less frequently in infants and children. The ECG manifestations of the BrS are often concealed and may be unmasked or aggravated by sodium channel blockers, a febrile state, vagotonic agents, as well as by tricyclic and tetracyclic antidepressants. An implantable cardioverter defibrillator (ICD) is the most widely accepted approach to therapy. Pharmacological therapy is designed to produce an inward shift in the balance of currents active during the early phases of the right ventricular action potential and can be used to abort electrical storms or as an adjunct or alternative to device therapy when use of an ICD is not possible. Isoproterenol, cilostazol and milrinone boost calcium channel current and drugs like quinidine, bepridil and the Chinese herb extract Wenxin Keli inhibit the transient outward current, acting to diminish the action potential (AP) notch and thus to suppress the substrate and trigger for VT/VF. Radiofrequency ablation of the right ventricular outflow tract epicardium of BrS patients has recently been shown to reduce arrhythmia-vulnerability and the ECG-manifestation of the disease, presumably by destroying the cells with more prominent AP notch. This review provides an overview of the clinical, genetic, molecular and cellular aspects of the BrS as well as the approach to therapy. PMID:26671757
SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalavagunta, C; Lasio, G; Yi, B
2015-06-15
Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquiredmore » for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.« less
Hao, Qing-Ying; Liu, Chu-Yin; Fu, Chan-Juan; Zhang, Xiao-Hua; Tan, Ming-Sheng
2016-01-01
Background: Continuous negative pressure drainage (CNPD) is widely used after lower lumbar internal fixation; however, it may cause tremendous blood loss and lead to postoperative hemorrhagic anemia. The present study explored the efficacy and safety of improved intermittent-clamped drainage (ICD) for lower lumbar internal fixation. Methods: This was a prospective study that included 156 patients with decompression of the spinal canal and internal fixation for the first time from January 2012 to December 2014. The patients were randomly divided into ICD group and CNPD group, and each group had 78 cases. A drainage tube was placed under the deep fascia in all patients within 10 min after the commencement of wound closure. The postoperative drainage amount at different time points, the hemoglobin level, and postoperative complications were recorded and compared between the two groups. Shapiro-Wilk test, independent samples t-test, and Mann-Whitney U-test were used in this study. Results: The drainage amount was significantly reduced in the ICD group, as compared with the CNPD group (Z = 10.74, P < 0.01). The mean total drainage amount (in ml) of the single-segment and two-segment procedures was significantly greater in the CNPD group than the ICD group (Z = 10.63 and 10.75, respectively; P < 0.01). For the adverse events, there was no significant difference in postoperative temperature, wound problem, and complications between the two groups. Conclusions: The present study showed a statistically significant reduction in postoperative drainage amount between ICD and CNPD groups, and ICD is an effective, convenient, and safe method for routine use in lower lumbar surgery. It is essential to focus on the effect of clamping drainage with long-segment surgical procedure and complex lumbar disease in the further investigation, as well as the effect of clamping on long-term functional outcomes. PMID:27900992
NASA Technical Reports Server (NTRS)
Hohnloser, S. H.; Klingenheben, T.; Li, Y. G.; Zabel, M.; Peetermans, J.; Cohen, R. J.
1998-01-01
INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.
Haravuori, Henna; Kiviruusu, Olli; Suomalainen, Laura; Marttunen, Mauri
2016-05-12
The proposed posttraumatic stress disorder (PTSD) criteria for the International Classification of Diseases (ICD) 11th revision are simpler than the criteria in ICD-10, DSM-IV or DSM-5. The aim of this study was to evaluate the ICD-11 PTSD factor structure in samples of young people, and to compare PTSD prevalence rates and diagnostic agreement between the different diagnostic systems. Possible differences in clinical characteristics of the PTSD cases identified by ICD-11, ICD-10 and DSM-IV are explored. Two samples of adolescents and young adults were followed after exposure to similar mass shooting incidents in their schools. Semi-structured diagnostic interviews were performed to assess psychiatric diagnoses and PTSD symptom scores (N = 228, mean age 17.6 years). PTSD symptom item scores were used to compose diagnoses according to the different classification systems. Confirmatory factor analyses indicated that the proposed ICD-11 PTSD symptoms represented two rather than three factors; re-experiencing and avoidance symptoms comprised one factor and hyperarousal symptoms the other factor. In the studied samples, the three-factor ICD-11 criteria identified 51 (22.4%) PTSD cases, the two-factor ICD-11 identified 56 (24.6%) cases and the DSM-IV identified 43 (18.9%) cases, while the number of cases identified by ICD-10 was larger, being 85 (37.3%) cases. Diagnostic agreement of the ICD-11 PTSD criteria with ICD-10 and DSM-IV was moderate, yet the diagnostic agreement turned to be good when an impairment criterion was imposed on ICD-10. Compared to ICD-11, ICD-10 identified cases with less severe trauma exposure and posttraumatic symptoms and DSM-IV identified cases with less severe trauma exposure. The findings suggest that the two-factor model of ICD-11 PTSD is preferable to the three-factor model. The proposed ICD-11 criteria are more restrictive compared to the ICD-10 criteria. There were some differences in the clinical characteristics of the PTSD cases identified by ICD-11, when compared to ICD-10 and DSM-IV.
Development of structured ICD-10 and its application to computer-assisted ICD coding.
Imai, Takeshi; Kajino, Masayuki; Sato, Megumi; Ohe, Kazuhiko
2010-01-01
This paper presents: (1) a framework of formal representation of ICD10, which functions as a bridge between ontological information and natural language expressions; and (2) a methodology to use formally described ICD10 for computer-assisted ICD coding. First, we analyzed and structurized the meanings of categories in 15 chapters of ICD10. Then we expanded the structured ICD10 (S-ICD10) by adding subordinate concepts and labels derived from Japanese Standard Disease Names. The information model to describe formal representation was refined repeatedly. The resultant model includes 74 types of semantic links. We also developed an ICD coding module based on S-ICD10 and a 'Coding Principle,' which achieved high accuracy (>70%) for four chapters. These results not only demonstrate the basic feasibility of our coding framework but might also inform the development of the information model for formal description framework in the ICD11 revision.
Römers, Hans; VAN Dijk, Vincent; Balt, Jippe
2017-06-01
We present the case of a 75-year-old patient with a single-chamber St. Jude Medical internal cardioverter defibrillator (ICD; St. Jude Medical, St. Paul, MN, USA) for primary prevention, who was admitted with 39 inappropriate ICD shocks because of atrial fibrillation with rapid ventricular frequention, despite magnet placement. Review of the device manual and literature revealed that apart from different responses to magnet placement programmed for the various manufacturers, the type of magnet and the positioning can be of specific interest. In the case presented, the donut-shaped magnet should have been placed off-center instead of directly over the device. © 2017 Wiley Periodicals, Inc.
Prospective cohort study of impulse control disorders in Parkinson's disease.
Bastiaens, Jesse; Dorfman, Benjamin J; Christos, Paul J; Nirenberg, Melissa J
2013-03-01
Impulse control disorders (ICDs) are potentially serious side effects of dopamine agonist therapy in Parkinson's disease (PD), but prospective data are lacking about their incidence, time course, and risk factors. This work was a 4-year, prospective cohort study of outpatients with PD and no previous ICDs (N = 164). All subjects treated with a dopamine agonist during the study were followed longitudinally for new-onset ICDs. Baseline characteristics were compared in groups with (ICD+) and without (ICD-) subsequent ICDs. Forty-six subjects were treated with a dopamine agonist, including 25 who were newly treated and 21 who received ongoing dopamine agonist therapy. Of these 46 subjects, 18 (39.1%) developed new-onset ICDs. The timing of ICD onset varied from 3.0 to 114.0 months (median, 23.0) after initiation of dopamine agonist therapy. Baseline demographic characteristics were similar in ICD+ and ICD- groups. At baseline, ICD+ subjects had a greater prevalence of motor complications (61.1% versus 25.0%; P = 0.01) than ICD- subjects, despite comparable total dopaminergic medication usage in both groups (median, 150.0 versus 150.0 levodopa equivalents; P = 0.61). Compared with ICD- subjects, ICD+ subjects had a greater baseline prevalence of caffeine use (100% versus 66.7%; P = 0.007) and higher lifetime prevalence of cigarette smoking (44.4% versus 14.3%; P = 0.04). Peak dopamine agonist doses were higher in ICD+ than ICD- subjects (median 300.0 versus 165.0 L-dopa equivalents; P = 0.03), but cumulative dopamine agonist exposure was similar in both groups. In summary, the timing of new-onset ICDs in PD is highly variable. Risk factors include cigarette smoking, caffeine use, motor complications, and higher peak dopamine agonist dosage. Copyright © 2013 Movement Disorders Society.
Primary Prevention Implantable Cardioverter-Defibrillators and Survival in Older Women
Zeitler, Emily P.; Hellkamp, Anne S.; Fonarow, Gregg C.; Hammill, Stephen C.; Curtis, Lesley H.; Hernandez, Adrian F.; Al-Khalidi, Hussein R.; Curtis, Jeptha P.; Heidenreich, Paul A.; Anstrom, Kevin J.; Peterson, Eric D.; Mark, Daniel B.; Hammill, Bradley G.; Sanders, Gillian D.; Al-Khatib, Sana M.
2015-01-01
OBJECTIVES The purpose of this study was to assess the benefit of primary prevention implantable cardioverter defibrillators (ICDs) in women. BACKGROUND Clinical trials of primary prevention ICDs enrolled a limited number of women. METHODS Using a propensity score method, we matched 490 women ≥65 years of age who received an ICD during a hospitalization for heart failure in the National Cardiovascular Data Registry ICD Registry from January 1, 2006, through December 31, 2007, to 490 ICD-eligible women without an ICD hospitalized for heart failure in the Get With The Guidelines for Heart Failure database from January 1, 2006, through December 31, 2009. The primary endpoint was all-cause mortality obtained from the Medicare Claims Database. An identical analysis was conducted in men. RESULTS Median follow-up for patients with an ICD was 4.6 years versus 3.2 years for patients with no ICD. Compared with women with no ICD, those with an ICD were younger and less frequently white. In the matched cohorts, the survival of women with an ICD was significantly longer than that of women without an ICD (adjusted hazard ratio: 0.79, 95% confidence interval: 0.66 to 0.95; p = 0.013). Similarly, men with an ICD had longer survival than men without an ICD (adjusted hazard ratio: 0.73, 95% confidence interval: 0.65 to 0.83; p < 0.0001). There was no interaction between sex and the presence of an ICD with respect to survival (p = 0.44). CONCLUSIONS Among older women with left ventricular dysfunction, a primary prevention ICD was associated with a significant survival benefit that was nearly identical to that seen in men. These findings support the use of primary prevention ICDs in eligible patients regardless of sex. PMID:25543969
Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich
2017-01-01
Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives: This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p < .001). Provisional PTSD prevalence was significantly increased under ICD-11 proposal compared to ICD-10 (30%) which was mainly due to the deletion of the time criterion. Agreement between ICD-10 and the proposed ICD-11 was low ( p = .014). Conclusion: This study provides preliminary evidence for a satisfactory concordance between provisional PTSD prevalence based on the diagnostic criteria for PTSD that are defined using DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11.
Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich
2017-01-01
ABSTRACT Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives:This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p < .001). Provisional PTSD prevalence was significantly increased under ICD-11 proposal compared to ICD-10 (30%) which was mainly due to the deletion of the time criterion. Agreement between ICD-10 and the proposed ICD-11 was low (p = .014). Conclusion: This study provides preliminary evidence for a satisfactory concordance between provisional PTSD prevalence based on the diagnostic criteria for PTSD that are defined using DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11. PMID:29163862
Utter, Garth H; Miller, Preston R; Mowery, Nathan T; Tominaga, Gail T; Gunter, Oliver; Osler, Turner M; Ciesla, David J; Agarwal, Suresh K; Inaba, Kenji; Aboutanos, Michel B; Brown, Carlos V R; Ross, Steven E; Crandall, Marie L; Shafi, Shahid
2015-05-01
The American Association for the Surgery of Trauma (AAST) recently established a grading system for uniform reporting of anatomic severity of several emergency general surgery (EGS) diseases. There are five grades of severity for each disease, ranging from I (lowest severity) to V (highest severity). However, the grading process requires manual chart review. We sought to evaluate whether International Classification of Diseases, 9th and 10th Revisions, Clinical Modification (ICD-9-CM, ICD-10-CM) codes might allow estimation of AAST grades for EGS diseases. The Patient Assessment and Outcomes Committee of the AAST reviewed all available ICD-9-CM and ICD-10-CM diagnosis codes relevant to 16 EGS diseases with available AAST grades. We then matched grades for each EGS disease with one or more ICD codes. We used the Official Coding Guidelines for ICD-9-CM and ICD-10-CM and the American Hospital Association's "Coding Clinic for ICD-9-CM" for coding guidance. The ICD codes did not allow for matching all five AAST grades of severity for each of the 16 diseases. With ICD-9-CM, six diseases mapped into four categories of severity (instead of five), another six diseases into three categories of severity, and four diseases into only two categories of severity. With ICD-10-CM, five diseases mapped into four categories of severity, seven diseases into three categories, and four diseases into two categories. Two diseases mapped into discontinuous categories of grades (two in ICD-9-CM and one in ICD-10-CM). Although resolution is limited, ICD-9-CM and ICD-10-CM diagnosis codes might have some utility in roughly approximating the severity of the AAST grades in the absence of more precise information. These ICD mappings should be validated and refined before widespread use to characterize EGS disease severity. In the long-term, it may be desirable to develop alternatives to ICD-9-CM and ICD-10-CM codes for routine collection of disease severity characteristics.
Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina; McNitt, Scott; Thomsen, Poul Erik Bloch; Klein, Helmut; Stockburger, Martin; Wichterle, Dan; Merkely, Bela; DE LA Concha, Joaquin Fernandez; Swissa, Moshe; Zareba, Wojciech; Moss, Arthur J; Kautzner, Josef; Ruwald, Martin H
2015-04-01
The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy. © 2014 Wiley Periodicals, Inc.
Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F; Flyvholm, Mari-Ann; Bonde, Jens P E; Johansen, Jeanne D
2014-12-01
Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. To characterize irritant exposures leading to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during January 2010-August 2011, in a programme consisting of a clinical examination, exposure assessment, and extensive patch/prick testing. OCD was diagnosed in 228 patients. Of these patients, 118 were diagnosed with OICD. The main irritant exposures identified were wet work (n = 64), gloves (n = 45), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact allergens, and 18 patients were exposed to 25 weak workplace contact allergens. In the present study, the systematic exposure assessment did not reveal any new irritants. MSDSs have a limited role in the investigation of ICD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Constantino, Jason; Long, Yun; Ashihara, Takashi; Trayanova, Natalia A.
2010-01-01
Background Following near-defibrillation threshold (DFT) shocks from an ICD, the first postshock activation that leads to defibrillation failure arises focally after an isolelectric window (IW). The mechanisms underlying the IW remain incompletely understood. Objective The goal of this study was to provide mechanistic insight into the origins of postshock activations and IW following ICD shocks, and to link shock outcome to the preshock state of the ventricles. We hypothesized that the non-uniform ICD field results in the formation of an intramural excitable area (tunnel) only in the LV free wall, through which both pre-existing and new shock-induced wavefronts propagate during the IW. Methods Simulations were conducted using a realistic 3-D model of defibrillation in the rabbit ventricles. Biphasic ICD shocks of varying strengths were delivered to 27 different fibrillatory states. Results Following near-DFT shocks, regardless of preshock state, the main postshock excitable area was always located within LV free wall, creating an intramural tunnel. Either preexisting fibrillatory or shock-induced wavefronts propagated during the IW (duration of up to 74ms) in this tunnel and emerged as breakthroughs on LV epicardium. Preshock activity within the LV played a significant role in shock outcome: large number of preshock filaments resulted in an IW associated with tunnel propagation of preexisting rather than shock-induced wavefronts. Furthermore, shocks were more likely to succeed if LV excitable area was smaller. Conclusions The LV intramural excitable area is the primary reason for near-DFT failure. Any intervention that decreases the extent of this area will improve the likelihood of defibrillation success. PMID:20348028
Wearable defibrillator use in heart failure (WIF): results of a prospective registry
2012-01-01
Background Heart failure (HF) patients have a high risk of death, and implantable cardioverter defibrillators (ICDs) are effective in preventing sudden cardiac death (SCD). However, a certain percentage of patients may not be immediate candidates for ICDs, particularly those having a short duration of risk or an uncertain amount of risk. This includes the newly diagnosed patients, as well as those on the cardiac transplant list or NYHA class IV heart failure patients who do not already have an ICD. In these patients, a wearable cardioverter defibrillator (WCD) may be used until long term risk of SCD is defined. The purpose of this study was to determine the incidence of SCD in this population, and the efficacy of early defibrillation by a WCD. Methods Ten enrolling centers identified 89 eligible HF patients who were either listed for cardiac transplantation, diagnosed with dilated cardiomyopathy, or receiving inotropic medications. Data collected included medical history, device records, and outcomes (including 90 day mortality). Results Out of 89 patients, final data on 82 patients has been collected. Patients wore the device for 75±58 days. Mean age was 56.8±13.2, and 72% were male. Most patients (98.8%) were diagnosed with dilated cardiomyopathy with a low ejection fraction (<40%) and twelve were listed for cardiac transplantation. Four patients were on inotropes. There were no sudden cardiac arrests or deaths during the study. Interestingly, 41.5% of patients were much improved after WCD use, while 34.1% went on to receive an ICD. Conclusions In conclusion, the WCD monitored HF patients until further assessment of risk. The leading reasons for end of WCD use were improvement in left ventricular ejection fraction (LVEF) or ICD implantation if there was no significant improvement in LVEF. PMID:23234574
Moore, Jeremy P; Mondésert, Blandine; Lloyd, Michael S; Cook, Stephen C; Zaidi, Ali N; Pass, Robert H; John, Anitha S; Fish, Frank A; Shannon, Kevin M; Aboulhosn, Jamil A; Khairy, Paul
2016-09-01
Sudden cardiac death is a major contributor to mortality for adults with congenital heart disease. The subcutaneous implantable cardioverter-defibrillator (ICD) has emerged as a novel tool for prevention of sudden cardiac death, but clinical performance data for adults with congenital heart disease are limited. A retrospective study involving 7 centers over a 5-year period beginning in 2011 was performed. Twenty-one patients (median 33.9 years) were identified. The most common diagnosis was single ventricle physiology (52%), 9 palliated by Fontan operation and 2 by aortopulmonary shunts: d-transposition of the great arteries after Mustard/Senning (n=2), tetralogy of Fallot (n=2), aortic valve disease (n=2), and other biventricular surgery (n=4). A prior cardiac device had been implanted in 7 (33%). The ICD indication was primary prevention in 67% and secondary in 33% patients. The most common reason for subcutaneous ICD placement was limited transvenous access for ventricular lead placement (n=10) followed by intracardiac right-to-left shunt (n=5). Ventricular arrhythmia was induced in 17 (81%) and was converted with ≤80 Joules in all. There was one implant complication related to infection, not requiring device removal. Over a median follow-up of 14 months, 4 patients (21%) received inappropriate and 1 (5%) patient received appropriate shocks. There was one arrhythmic death related to asystole in a single ventricle patient. Subcutaneous ICD implantation is feasible for adults with congenital heart disease patients. Most candidates have single ventricle heart disease and limited transvenous options for ICD placement. Despite variable anatomy, this study demonstrates successful conversion of induced ventricular arrhythmia and reasonable rhythm discrimination during follow-up. © 2016 American Heart Association, Inc.
Chiu, Hsienhsueh Elley; Hong, Yu-Chiang; Chang, Ku-Chou; Shih, Chun-Chuan; Hung, Jen-Wen; Liu, Chia-Wei; Tan, Teng-Yeow; Huang, Chih-Cheng
2014-01-01
Abstract Background This study searches the National Health Insurance Research Database (NHIRD) used in a previous project, aiming for reconstructing possible cerebrovascular disease-related groups (DRG),and estimating the costs between cerebrovascular disease and related diseases. Methods and Materials We conducted a nationwide retrospective cohort study in stroke inpatients, we examined the overall costs in 3 municipalities in Taiwan, by evaluating the possible costs of the expecting diagnosis related group (DRG) by using the international classification of diseases version-9 (ICD-9) system, and the overall analysis of the re-admission population that received traditional Chinese medicine (TCM) treatment and those who did not. Results The trend demonstrated that the non-participant costs were consistent with the ICD-9 categories (430 to 437) because similarities existed between years 2006 to 2007. Among the TCM patients, a wide variation and additional costs were found compared to non-TCM patients during these 2 years. The average re-admission duration was significantly shorter for TCM patients, especially those initially diagnosed with ICD 434 during the first admission. In addition, TCM patients demonstrated more severe general symptoms, which incurred high conventional treatment costs, and could result in re-admission for numerous reasons. However, in Disease 7 of ICD-9 category, representing the circulatory system was most prevalent in non-TCM inpatients, which was the leading cause of re-admission. Conclusion We concluded that favorable circulatory system outcomes were in adjuvant TCM treatment inpatients, there were less re-admission for circulatory system events and a two-third reduction of re-admission within ICD-9 code 430 to 437, compared to non-TCM ones. However, there were shorter re-admission duration other than circulatory system events by means of unfavorable baseline condition. PMID:24475108
The learning curve associated with the introduction of the subcutaneous implantable defibrillator.
Knops, Reinoud E; Brouwer, Tom F; Barr, Craig S; Theuns, Dominic A; Boersma, Lucas; Weiss, Raul; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D; Leon, Angel R; Hood, Margaret; Jones, Paul W; Wold, Nicholas; Grace, Andrew A; Olde Nordkamp, Louise R A; Burke, Martin C
2016-07-01
The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters with respect to implant-related complications, procedure time, and inappropriate shocks (IASs). In a pooled cohort from two clinical S-ICD databases, the IDE Trial and the EFFORTLESS Registry, complications, IASs at 180 days follow-up and implant procedure duration were assessed. Patients were grouped in quartiles based on experience of the implanter and Kaplan-Meier estimates of complication and IAS rates were calculated. A total of 882 patients implanted in 61 centres by 107 implanters with a median of 4 implants (IQR 1,8) were analysed. There were a total of 59 patients with complications and 48 patients with IAS. The complication rate decreased significantly from 9.8% in Quartile 1 (least experience) to 5.4% in Quartile 4 (most experience) (P = 0.02) and non-significantly for IAS from 7.9 to 4.8% (P = 0.10). Multivariable analysis demonstrated a hazard ratio of 0.78 (P = 0.045) for complications and 1.01 (P = 0.958) for IAS. Dual-zone programming increased with experience of the individual implanter (P < 0.001), which reduced IAS significantly in the multivariable model (HR 0.44, P = 0.01). Procedure time decreased from 75 to 65 min (P < 0.001). The complication rate and procedure time stabilized after Quartile 2 (>13 implants). There is a short and significant learning curve associated with physicians adopting the S-ICD. Performance stabilizes after 13 implants. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
Essebag, Vidal; Joza, Jacqueline; Birnie, David H; Sapp, John L; Sterns, Laurence D; Philippon, Francois; Yee, Raymond; Crystal, Eugene; Kus, Teresa; Rinne, Claus; Healey, Jeffrey S; Sami, Magdi; Thibault, Bernard; Exner, Derek V; Coutu, Benoit; Simpson, Chris S; Wulffhart, Zaev; Yetisir, Elizabeth; Wells, George; Tang, Anthony S L
2015-02-01
The resynchronization-defibrillation for ambulatory heart failure trial (RAFT) study demonstrated that adding cardiac resynchronization therapy (CRT) in selected patients requiring de novo implantable cardiac defibrillators (ICD) reduced mortality as compared with ICD therapy alone, despite an increase in procedure-related adverse events. Data are lacking regarding the management of patients with ICD therapy who develop an indication for CRT upgrade. Participating RAFT centers provided data regarding de novo CRT-D (CRT with ICD) implant, upgrade to CRT-D during RAFT (study upgrade), and upgrade within 6 months after presentation of study results (substudy). Substudy centers enrolled 1346 (74.9%) patients in RAFT, including 644 de novo, 80 study upgrade, and 60 substudy CRT attempts. The success rate (initial plus repeat attempts) was 95.2% for de novo versus 96.3% for study upgrade and 90.0% for substudy CRT attempts (P=0.402). Acute complications occurred among 26.2% of de novo versus 18.8% of study upgrade and 3.4% of substudy CRT implantation attempts (P<0.001). The most common complication was left ventricular lead dislodgement. The principal reasons for not yet attempting upgrade in the substudy were patient preference (31.9%), New York Heart Association Class I (17.0%), and a QRS<150 ms (13.1%). Among a broad group of implant physicians, CRT upgrades were performed in patients with an ICD in situ with no difference in implant success rate and a reduced acute complication rate as compared with a de novo CRT implant. Decisions to upgrade were influenced by predictors of benefit in subgroup analyses of the RAFT study and other trials. © 2014 American Heart Association, Inc.
Electrical Storm: Incidence, Prognosis and Therapy.
Sagone, Antonio
2015-12-01
The term "electrical storm" indicates a life-threatening clinical condition characterized by the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, in particular in patients with ICD implanted for primary or secondary prevention. Although there isn't a shared definition of electrical storm, nowadays the most accepted definition refers to three or more separate arrhythmia episodes leading to ICD therapies including antitachycardia pacing or shock occurring over a single 24 hours' time period. Clinical presentation can be dramatic and triggering mechanism are not clear at all yet, but electrical storm is associated with high mortality rates and low patients quality of life, both in the acute phase and in the long term. The first line therapy is based on antiarrhythmic drugs to suppress electrical storm, but in refractory patients, interventions such as catheter ablation or in some cases surgical cardiac sympathetic denervation might be helpful. Anyhow, earlier interventional management can lead to better outcomes than persisting with antiarrhythmic pharmacologic therapy and, when available, an early interventional approach should be preferred.
Heinemann, Christian; Schliemann-Willers, Sibylle; Oberthür, Christine; Hamburger, Matthias; Elsner, Peter
2004-05-01
Lipophilic extracts of Isatis tinctoria L. exhibit significant activity against several clinically relevant targets of inflammation. The alkaloid tryptanthrin was identified as one of the active principles in woad and characterised as a potent dual inhibitor of COX-2 and 5-LOX. Here, the anti-inflammatory efficacy of topical application of three different Isatis extracts and tryptanthrin was investigated in human volunteers. Two different models were used, namely the sodium lauryl sulphate (SLS)-induced irritant contact dermatitis (ICD) and UVB-induced erythema. Twenty healthy volunteers without any skin disease participated in the study. Cumulative irritant contact dermatitis was induced on test fields on the volunteers' backs by twice daily application of 0.5 % sodium lauryl sulphate over a period of four days. Half of the test fields were treated with the test substances during the eliciting phase, while the remaining test fields were treated over a period of 4 days after induction of dermatitis. In the second model, a UVB erythema on the volunteers' lower backs was induced using the double minimal erythema dose (MED). Twenty-four hours after irradiation the test fields were treated with the test substances over a period of 3 days. All reactions were assessed visually and by non-invasive bioengineering methods (evaporimetry and chromametry). Treatment with extracts during the ICD eliciting phase led to a significantly smaller increase of visual scores and transepidermal water loss compared to the untreated test field. For tryptanthrin this benefit was also observed, but the improvement was not statistically significant. When treatment was performed after completing the eliciting phase, accelerated resolution of the irritant reaction could not be observed. In the UVB erythema model anti-inflammatory effects of the test substances were not observed.
Opić, Petra; Utens, Elisabeth M W J; Moons, Philip; Theuns, Dominic A M J; van Dijk, Arie P J; Hoendermis, Elke S; Vliegen, Hubert W; de Groot, Natasja M S; Witsenburg, Maarten; Schalij, Martin; Roos-Hesselink, Jolien W
2012-07-01
To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). Included were 26 ToF-patients with an ICD (age 44 ± 12 years), and two control groups consisting of 28 ToF-patients without an ICD (age 40 ± 10 years) and a group of 35 ICD-patients of older age without ToF (age 72.0 ± 8 years). This last control group was chosen to represent the "older general ICD population" with acquired heart disease seen at the out-patient clinic. Psychosocial functioning encompassed daily functioning, subjective health status, quality of life, anxiety, depression, coping and social support. ToF-patients with ICD showed diminished psychosocial functioning in comparison to ToF-patients without ICD. This was reflected by diminished subjectively perceived physical functioning (p = 0.01), general health perception (p < 0.01) and a lower satisfaction with life (p = 0.02). In comparison to older ICD-patients, ToF-patients with ICD showed less satisfaction with life (p = 0.03), experienced more anxiety (p = 0.01) and showed less favourable coping styles, although physical functioning was better for ToF-patients with ICD than for older ICD-patients (p = 0.01). More inappropriate shocks were found in ToF-patients with ICD compared to the older ICD-patients. In patients with ToF, ICD implantation had a major impact on psychosocial functioning which should be taken into account when considering ICD implantation in these young patients. To help improve psychosocial functioning, psychological counselling attuned to the specific needs of these patients may be useful.
The Italian subcutaneous implantable cardioverter-defibrillator survey: S-ICD, why not?
Botto, Giovanni Luca; Forleo, Giovanni B; Capucci, Alessandro; Solimene, Francesco; Vado, Antonello; Bertero, Giovanni; Palmisano, Pietro; Pisanò, Ennio; Rapacciuolo, Antonio; Infusino, Tommaso; Vicentini, Alessandro; Viscusi, Miguel; Ferrari, Paola; Talarico, Antonello; Russo, Giovanni; Boriani, Giuseppe; Padeletti, Luigi; Lovecchio, Mariolina; Valsecchi, Sergio; D'Onofrio, Antonio
2017-11-01
A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. The survey 'S-ICD Why Not?' was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.
Zhao, Xiao; Yang, Keni; Zhao, Ruifang; Ji, Tianjiao; Wang, Xiuchao; Yang, Xiao; Zhang, Yinlong; Cheng, Keman; Liu, Shaoli; Hao, Jihui; Ren, He; Leong, Kam W; Nie, Guangjun
2016-09-01
Immunogenic cell death (ICD) occurs when apoptotic tumor cell elicits a specific immune response, which may trigger an anti-tumor effect, via the release of immunostimulatory damage-associated molecular patterns (DAMPs). Hypothesizing that nanomedicines may impact ICD due to their proven advantages in delivery of chemotherapeutics, we encapsulated oxaliplatin (OXA) or gemcitabine (GEM), an ICD and a non-ICD inducer respectively, into the amphiphilic diblock copolymer nanoparticles. Neither GEM nor nanoparticle-encapsulated GEM (NP-GEM) induced ICD, while both OXA and nanoparticle-encapsulated OXA (NP-OXA) induced ICD. Interestingly, NP-OXA treated tumor cells released more DAMPs and induced stronger immune responses of dendritic cells and T lymphocytes than OXA treatment in vitro. Furthermore, OXA and NP-OXA exhibited stronger therapeutic effects in immunocompetent mice than in immunodeficient mice, and the enhancement of therapeutic efficacy was significantly higher in the NP-OXA group than the OXA group. Moreover, NP-OXA treatment induced a higher proportion of tumor infiltrating activated cytotoxic T-lymphocytes than OXA treatment. This general trend of enhanced ICD by nanoparticle delivery was corroborated in evaluating another pair of ICD inducer and non-ICD inducer, doxorubicin and 5-fluorouracil. In conclusion, although nanoparticle encapsulation did not endow a non-ICD inducer with ICD-mediated anti-tumor capacity, treatment with a nanoparticle-encapsulated ICD inducer led to significantly enhanced ICD and consequently improved anti-tumor effects than the free ICD inducer. The proposed nanomedicine approach may impact cancer immunotherapy via the novel cell death mechanism of ICD. Copyright © 2016 Elsevier Ltd. All rights reserved.
Svanholm, Jette Rolf; Nielsen, Jens Cosedis; Mortensen, Peter; Christensen, Charlotte Fuglesang; Birkelund, Regner
2015-11-01
More than 20% of implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy (CRT) devices are implanted in the elderly population aged 80 years or older. In recent scientific literature it is suggested to consider termination of ICD therapy, rather than ICD replacement, in this patient group. The aim of this study was to explore the experiences of persons above 80 years of age concerning replacement of the ICD battery, and the shared communication and decision making with healthcare professionals. We performed a qualitative, explorative study, inspired by Ricoeur's narrative, with a phenomenological-hermeneutic approach, involving 11 ICD patients older than 80 years. The study period was 2011-2012. The meaning of the patients' experiences of living with an ICD was formulated into two themes: (1) "Feeling safe with the ICD" with the subthemes: "The ICD-a life keeper," "The battery level is important," "ICD shock-no problem." (2) "The physician is an authority" with the subthemes: "Being trustful," "Feeling fine knowing nothing," "Criminal act to deactivate the ICD." The elderly ICD recipients tended not to be aware of the option of declining replacement of their ICD. They tended to expect to have their ICD replaced and not to be involved actively in decision making concerning this. Healthcare professionals have an obligation to discuss options and ensure that every patient understands these. More research is needed to change practices and create more realistic, person-centered, ethically acceptable, and constructive healthcare for elderly persons with an ICD. © 2015 Wiley Periodicals, Inc.
Optimal Implantable Cardioverter Defibrillator Programming.
Shah, Bindi K
Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.
77 FR 48985 - Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-15
... Topics: ICD-10 Implementation Announcements Expansion of Thoracic Aorta Body Part Under Heart and Great... from thoracic aorta to abdominal aorta) ICD-10 MS-DRGs ICD-10 HAC Translations ICD-10 MCE Translations...
Validation of ICDPIC software injury severity scores using a large regional trauma registry.
Greene, Nathaniel H; Kernic, Mary A; Vavilala, Monica S; Rivara, Frederick P
2015-10-01
Administrative or quality improvement registries may or may not contain the elements needed for investigations by trauma researchers. International Classification of Diseases Program for Injury Categorisation (ICDPIC), a statistical program available through Stata, is a powerful tool that can extract injury severity scores from ICD-9-CM codes. We conducted a validation study for use of the ICDPIC in trauma research. We conducted a retrospective cohort validation study of 40,418 patients with injury using a large regional trauma registry. ICDPIC-generated AIS scores for each body region were compared with trauma registry AIS scores (gold standard) in adult and paediatric populations. A separate analysis was conducted among patients with traumatic brain injury (TBI) comparing the ICDPIC tool with ICD-9-CM embedded severity codes. Performance in characterising overall injury severity, by the ISS, was also assessed. The ICDPIC tool generated substantial correlations in thoracic and abdominal trauma (weighted κ 0.87-0.92), and in head and neck trauma (weighted κ 0.76-0.83). The ICDPIC tool captured TBI severity better than ICD-9-CM code embedded severity and offered the advantage of generating a severity value for every patient (rather than having missing data). Its ability to produce an accurate severity score was consistent within each body region as well as overall. The ICDPIC tool performs well in classifying injury severity and is superior to ICD-9-CM embedded severity for TBI. Use of ICDPIC demonstrates substantial efficiency and may be a preferred tool in determining injury severity for large trauma datasets, provided researchers understand its limitations and take caution when examining smaller trauma datasets. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Hoang, Allen; Shen, Changyu; Zheng, James; Taylor, Stanley; Groh, William J; Rosenman, Marc; Buxton, Alfred E.; Chen, Peng-Sheng
2014-01-01
Background Utilization rates (URs) for implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden cardiac death (PPSCD) are lacking in the community. Objective To establish the ICD UR in central Indiana. Methods A query run on two hospitals in a health information exchange database in Indianapolis identified patients between 2011 and 2012 with left ventricular ejection fraction (EF) ≤0.35. ICD-eligibility and utilization were determined from chart review. Results We identified 1,863 patients with at least one low-EF study. Two cohorts were analyzed: 1,672 patients without, and 191 patients with, ICD-9-CM procedure code 37.94 for ICD placement. We manually reviewed a stratified (by hospital) random sample of 300 patients from the no-ICD procedure code cohort and found that 48 (16%) had no ICD but had class I indications for ICD. Eight of 300 (2.7%) actually had ICD implantation for PPSCD. Review of all 191 patients in the ICD procedure code cohort identified 70 with ICD implantation for PPSCD. The ICD UR (ratio between patients with ICD for PPSCD and all with indication) was 38% overall (95% CI 28–49%). URs were 48% for males (95% CI 34–61%), 21% for females (95% CI 16–26%, p=0.0002 vs males), 40% for whites (95% CI 27–53%), and 37% for blacks (95% CI 28–46%, p=0.66 vs whites). Conclusions The ICD UR is 38% among patients meeting Class I indications, suggesting further opportunities to improve guideline compliance. Furthermore, this study illustrates limitations in calculating ICD UR using large electronic repositories without hands-on chart review. PMID:24566233
Jalilvand, Aryan; Fleming, Margaret; Moreno, Courtney; MacFarlane, Dan; Duszak, Richard
2018-01-01
The 2015 conversion of the International Classification of Diseases (ICD) system from the ninth revision (ICD-9) to the 10th revision (ICD-10) was widely projected to adversely impact physician practices. We aimed to assess code conversion impact factor (CCIF) projections and revenue delay impact to help radiology groups better prepare for eventual conversion to ICD, 11th revision (ICD-11). Studying 673,600 claims for 179 radiologists for the first year after ICD-10's implementation, we identified primary ICD-10 codes for the top 90th percentile of all examinations for the entire enterprise and each subspecialty division. Using established methodology, we calculated CCIFs (actual ICD-10 codes ÷ prior ICD-9 codes). To assess ICD-10's impact on cash flow, average monthly days in accounts receivable status was compared for the 12 months before and after conversion. Of all 69,823 ICD-10 codes, only 7,075 were used to report primary diagnoses across the entire practice, and just 562 were used to report 90% of all claims, compared with 348 under ICD-9. This translates to an overall CCIF of 1.6 for the department (far less than the literature-predicted 6). By subspecialty division, CCIFs ranged from 0.7 (breast) to 3.5 (musculoskeletal). Monthly average days in accounts receivable for the 12 months before and after ICD-10 conversion did not increase. The operational impact of the ICD-10 transition on radiology practices appears far less than anticipated with respect to both CCIF and delays in cash flow. Predictive models should be refined to help practices better prepare for ICD-11. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Expanding the definition of addiction: DSM-5 vs. ICD-11.
Grant, Jon E; Chamberlain, Samuel R
2016-08-01
While considerable efforts have been made to understand the neurobiological basis of substance addiction, the potentially "addictive" qualities of repetitive behaviors, and whether such behaviors constitute "behavioral addictions," is relatively neglected. It has been suggested that some conditions, such as gambling disorder, compulsive stealing, compulsive buying, compulsive sexual behavior, and problem Internet use, have phenomenological and neurobiological parallels with substance use disorders. This review considers how the issue of "behavioral addictions" has been handled by latest revisions of the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD), leading to somewhat divergent approaches. We also consider key areas for future research in order to address optimal diagnostic classification and treatments for such repetitive, debilitating behaviors.
Dougherty, Cynthia M.; Johnston, Sandra K.; Thompson, Elaine Adams
2009-01-01
The purpose of this study was to assess the reliability and validity characteristics of two new scales that measure self-efficacy expectations (SE-ICD) and outcome expectations (OE-ICD) in survivors (n=168) of sudden cardiac arrest (SCA), all of whom received an implantable cardioverter defibrillator (ICD). Cronbach's alpha reliability demonstrated good internal consistency (SE-ICD α = 0.93 and OE-ICD α = 0.81). Correlations with other self-efficacy instruments (general self-efficacy and social self-efficacy) were consistently high. The instruments were responsive to change across time with effect sizes of 0.46 for SE-ICD, and 0.26 for OE-ICD. These reliable, valid, and responsive instruments for measurement of self-efficacy expectations and outcome expectations after an ICD can be used in research and clinical settings. PMID:17693214
76 FR 51985 - ICD-9-CM Coordination and Maintenance Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-19
... and Public Health Data Standards Staff, announces the following meeting. Name: ICD-9-CM Coordination.... 2012 ICD-10-PCS GEM and Reimbursement Map Updates. ICD-10-PCS Official Coding Guidelines. ICD-10 MS... Pickett, Medical Systems Administrator, Classifications and Public Health Data Standards Staff, NCHS, 3311...
Simson, Udo; Perings, Christian; Plaskuda, Ariane; Schäfer, Ralf; Brehm, Michael; Bader, Doris; Tress, Wolfgang; Franz, Matthias
2006-12-01
OBJECTIVE It is well known fact, that the life of ICD patients is often affected by anxiety and depression. The number of ICD discharges is only a contributing factor explaining the variance of anxiety and depression. There have to be other factors that have more influence on the physical strain of ICD patients. In this study we examined the impact of attachment style and social support in addition to the number of ICD discharges. METHODS 119 out-patients at an out-patient ICD unit were examined consecutively with the following self report scales: (1) the State-Trait-Anxiety Inventory (STAI), (2) the Beck Depression Inventory (BDI), (3) a short form of a social support questionnaire (F-SOZU), (4) the Bielefeld Partnership Expectations Questionnaire (BFPE) and (5) a specifically designed questionnaire for the assessment of sociodemografic data. To determine the frequency and timing of the ICD discharges we analysed the ICD data. RESULTS 38 % of the ICD patients reported enhanced anxiety levels and 37 % reported enhanced depression levels. Only 38 % of the ICD patients received discharges at all. Elevated levels of anxiety and depression were found in patients who showed insecure attachment styles, low social support, long-term treatment in hospital and a higher number of ICD discharges. To explain the variance of anxiety we found social support, attachment style, and the number of ICD storms to be contributing factors. To explain the variance of depression we found social support and time spent in hospital in the previous year to be contributing factors. CONCLUSIONS Almost half of the ICD patients suffer considerably from anxiety and/or depression. These patients have to be identified and treated psychotherapeutically. Patients who show insecure attachment styles, receive low social support, undergo long-term treatment in hospital and receive a higher number of discharges, especially so called ICD storms, bear the highest risk to develop psychological strain. Attachment style and social support have even more impact on the development of anxiety and depression than the number of ICD discharges. It has to be shown in future studies whether psychotherapy can improve the quality of life of ICD patients.
Hoang, Allen; Shen, Changyu; Zheng, James; Taylor, Stanley; Groh, William J; Rosenman, Marc; Buxton, Alfred E; Chen, Peng-Sheng
2014-05-01
Utilization rates (URs) for implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden cardiac death (PPSCD) are lacking in the community. The purpose of this study was to establish the ICD UR in central Indiana. A query run on 2 hospitals in a health information exchange database in Indianapolis identified patients between 2011 and 2012 with left ventricular ejection fraction (EF) ≤0.35. ICD eligibility and utilization were determined from chart review. We identified 1863 patients with at least 1 low EF study. Two cohorts were analyzed: 1672 patients without and 191 patients with International Classification of Diseases, Ninth Revision, Clinical Modification procedure code 37.94 for ICD placement. We manually reviewed a stratified (by hospital) random sample of 300 patients from the no-ICD procedure code cohort and found that 48 (16%) had no ICD but had class I indications for ICD. Eight of 300 (2.7%) actually had ICD implantation for PPSCD. Review of all 191 patients in the ICD procedure code cohort identified 70 with ICD implantation for PPSCD. The ICD UR (ratio between patients with ICD for PPSCD and all with indication) was 38% overall (95% confidence interval [CI] 28%-49%). URs were 48% for males (95% CI 34%-61%), 21% for females (95% CI 16%-26%, P = .0002 vs males), 40% for whites (95% CI 27%-53%), and 37% for blacks (95% CI 28%-46%, P = .66 vs whites). ICD UR is 38% among patients meeting class I indications, suggesting further opportunities for improving guideline compliance. This study also illustrates limitations in calculating ICD UR using large electronic repositories without hands-on chart review. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Duru, Firat; Dorian, Paul; Favale, Stefano; Perings, Christian; Pedersen, Susanne S; Willems, Vincent
2010-05-01
Implantable cardioverter defibrillators (ICD) can prevent sudden cardiac death by delivering high-energy shocks in patients at risk of life-threatening ventricular tachyarrhythmias. Patients may be anxious about receiving inappropriate shocks in case of device or lead system malfunction, or about failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety. The trial will randomly assign 356 patients in a 1:1 design to a control group (PN OFF) vs. a treatment group (PN ON). Patients will be followed for 12 months, with visits scheduled at 6 and 12 months. During clinical follow-up visits, the ICD will be interrogated, and all patients will complete the Hospital Anxiety and Depression Scale and a device-related anxiety questionnaire. The sensitivity and specificity of PN, the effect of personality on anxiety, using the Type D scale (DS14), the number of delivered appropriate and inappropriate ICD therapies, changes in anxiety related to the delivery of appropriate or inappropriate shocks, crossovers from the assigned group, the number of hospitalizations, and the mortality rate will also be assessed. ClinicalTrials.gov Identifier: NCT00559559.
Chung, Tammy; Cornelius, Jack; Clark, Duncan; Martin, Christopher
2017-09-01
Proposed International Classification of Diseases, 11th edition (ICD-11), criteria for substance use disorder (SUD) radically simplify the algorithm used to diagnose substance dependence. Major differences in case identification across DSM and ICD impact determinations of treatment need and conceptualizations of substance dependence. This study compared the draft algorithm for ICD-11 SUD against DSM-IV, DSM-5, and ICD-10, for alcohol and cannabis. Adolescents (n = 339, ages 14 to 18) admitted to intensive outpatient addictions treatment completed, as part of a research study, a Structured Clinical Interview for DSM SUDs adapted for use with adolescents and which has been used to assess DSM and ICD SUD diagnoses. Analyses examined prevalence across classification systems, diagnostic concordance, and sources of diagnostic disagreement. Prevalence of any past-year proposed ICD-11 alcohol or cannabis use disorder was significantly lower compared to DSM-IV and DSM-5 (ps < 0.01). However, prevalence of proposed ICD-11 alcohol and cannabis dependence diagnoses was significantly higher compared to DSM-IV, DSM-5, and ICD-10 (ps < 0.01). ICD-11 and DSM-5 SUD diagnoses showed only moderate concordance. For both alcohol and cannabis, youth typically met criteria for an ICD-11 dependence diagnosis by reporting tolerance and much time spent using or recovering from the substance, rather than symptoms indicating impaired control over use. The proposed ICD-11 dependence algorithm appears to "overdiagnose" dependence on alcohol and cannabis relative to DSM-IV and ICD-10 dependence, and DSM-5 moderate/severe use disorder, generating potential "false-positive" cases of dependence. Among youth who met criteria for proposed ICD-11 dependence, few reported impaired control over substance use, highlighting ongoing issues in the conceptualization and diagnosis of SUD. Copyright © 2017 by the Research Society on Alcoholism.
Riordan, Rick
2013-01-01
Background/Aims With the implementation of ICD 10 CM and ICD 10 PCS less than two years away, there are still unanswered questions as to how research teams will effectively translate or use ICD 10 codes in research. Approximately 84% of the ICD 10 codes have only approximate matches with 10% having multiple matches and only 5% have exact one-to-one matches between ICD 9 and ICD 10. With the number of codes increasing five-fold, this offers additional opportunities and risks when pulling data. Methods Besides looking at the General Equivalency Mappings and other tools that are used to translate ICD 9 codes to ICD 10 codes, we will examine some common research areas where only approximate matches between ICD 9 and ICD 10 exist. We will also discuss how the finer level of detail that ICD 10 gives allows research teams to pinpoint exactly what type of asthma, Crohn’s disease, and diabetic retinopathy they wish to study without including some of the other cases that do not meet their research criteria. Results There are significant ambiguities and irregularity in several common areas such as diabetes, mental health, asthma, and gastroenterology due to approximate, multiple, or combination matches. Even in the case of exact matches such as an old myocardial infarction where there is an exact match, the definition of when a myocardial infarction becomes “old” is different. Conclusions ICD 10 offers a finer level of detail and a higher level of specificity, thereby allowing research teams to be more targeted when pulling data. On the other hand, research teams need to exercise caution when using GEMs and other tools to translate ICD 9 codes into ICD 10 codes and vice versa, especially if they are looking at data that overlaps the implementation date of October 1, 2014.
2014-01-01
Background The pediatric complex chronic conditions (CCC) classification system, developed in 2000, requires revision to accommodate the International Classification of Disease 10th Revision (ICD-10). To update the CCC classification system, we incorporated ICD-9 diagnostic codes that had been either omitted or incorrectly specified in the original system, and then translated between ICD-9 and ICD-10 using General Equivalence Mappings (GEMs). We further reviewed all codes in the ICD-9 and ICD-10 systems to include both diagnostic and procedural codes indicative of technology dependence or organ transplantation. We applied the provisional CCC version 2 (v2) system to death certificate information and 2 databases of health utilization, reviewed the resulting CCC classifications, and corrected any misclassifications. Finally, we evaluated performance of the CCC v2 system by assessing: 1) the stability of the system between ICD-9 and ICD-10 codes using data which included both ICD-9 codes and ICD-10 codes; 2) the year-to-year stability before and after ICD-10 implementation; and 3) the proportions of patients classified as having a CCC in both the v1 and v2 systems. Results The CCC v2 classification system consists of diagnostic and procedural codes that incorporate a new neonatal CCC category as well as domains of complexity arising from technology dependence or organ transplantation. CCC v2 demonstrated close comparability between ICD-9 and ICD-10 and did not detect significant discontinuity in temporal trends of death in the United States. Compared to the original system, CCC v2 resulted in a 1.0% absolute (10% relative) increase in the number of patients identified as having a CCC in national hospitalization dataset, and a 0.4% absolute (24% relative) increase in a national emergency department dataset. Conclusions The updated CCC v2 system is comprehensive and multidimensional, and provides a necessary update to accommodate widespread implementation of ICD-10. PMID:25102958
Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen
2016-08-05
With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
The Use of Advance Directives Among Patients With Implantable Cardioverter Defibrillators
Tajouri, Tanya H.; Ottenberg, Abigale L.; Hayes, David L.; Mueller, Paul S.
2013-01-01
Background We aimed to determine the prevalence of advance directives (ADs) among patients with implantable cardioverter defibrillators (ICDs) and of ADs that addressed ICD management at the end of life. Methods The medical records of all patients who underwent ICD implantation during 2007 at a single institution were reviewed retrospectively to determine the number of patients with an AD and the number of ADs mentioning the ICD specifically (ie, ICD management at end of life). Results During 2007, 420 patients (males, 71%) underwent ICD implantation at our institution (mean age [range] at implantation, 63 [1–90] years). Primary prevention was the most common indication for device therapy (254 patients [61%]). Overall, 127 patients (30%) had an AD, with 83 ADs (65%) completed more than 12 months before ICD implantation and 10 (8%) completed after it. Several life-sustaining treatments were mentioned in the ADs: tube feeding, 46 (37%); cardiopulmonary resuscitation, 25 (20%); mechanical ventilation, 22 (17%); and hemodialysis, 9 (7%). Pain control was mentioned in 58 ADs (46%) and comfort measures in 38 (30%). However, only 2 ADs (2%) mentioned the ICD or its deactivation at end of life. Conclusions About one-third of patients with ICDs had an AD, but only a couple ADs mentioned the ICD. These results suggest that clinicians should not only encourage patients with ICDs to complete an AD, but also encourage them to address ICD management specifically. Not addressing ICD management in an AD may result in ethical dilemmas during end-of- life care. PMID:22432897
Rahmawati, Anita; Chishaki, Akiko; Ohkusa, Tomoko; Sawatari, Hiroyuki; Tsuchihashi-Makaya, Miyuki; Ohtsuka, Yuko; Nakai, Mori; Miyazono, Mami; Hashiguchi, Nobuko; Sakurada, Harumizu; Takemoto, Masao; Mukai, Yasushi; Inoue, Shujirou; Sunagawa, Kenji; Chishaki, Hiroaki
2016-04-01
Implantable cardioverter-defibrillators (ICDs) have been established for primary and secondary prevention of fatal arrhythmias. However, little is known about the influence of ICD indications on quality of life (QOL) and psychological disturbances. This study aimed to examine whether there were differences in QOL and psychological distress in patients that have an ICD for primary or secondary prevention of fatal arrhythmias. A multicenter survey of 179 consecutive outpatients (29.1% primary prevention) with ICD implantations completed the Short Form-8 (SF-8), Beck Depression Inventory (BDI), Impact of Event Scale-Revised (IES-R), State-Trait Anxiety Inventory (STAI), and Worries about ICD (WAICD). Patients with an ICD for primary prevention had a higher trait anxiety score and worries about ICD score than patients with an ICD for secondary prevention (41.7±12.4 vs. 34.7±12.3, p=0.001 and 39.6±18.0 vs. 30.0±18.9, p=0.002, respectively), even after adjusting for demographic and clinical characteristics. In multivariable analysis of variance, primary prevention ICD recipients reported a poorer QOL on the vitality subscale of the SF-8. In our study population, which mostly consisted of New York Heart Association (NYHA) class I and II subjects, primary prevention ICD recipients were more prone to experience worries about their ICD, anxiety, and a poorer QOL compared to secondary prevention ICD recipients. In clinical practice, primary prevention ICD patients should be closely monitored. If warranted, they should be offered psychological intervention, as anxiety and low QOL were predictors of mortality.
Rahmawati, Anita; Chishaki, Akiko; Ohkusa, Tomoko; Sawatari, Hiroyuki; Tsuchihashi-Makaya, Miyuki; Ohtsuka, Yuko; Nakai, Mori; Miyazono, Mami; Hashiguchi, Nobuko; Sakurada, Harumizu; Takemoto, Masao; Mukai, Yasushi; Inoue, Shujirou; Sunagawa, Kenji; Chishaki, Hiroaki
2015-01-01
Background Implantable cardioverter-defibrillators (ICDs) have been established for primary and secondary prevention of fatal arrhythmias. However, little is known about the influence of ICD indications on quality of life (QOL) and psychological disturbances. This study aimed to examine whether there were differences in QOL and psychological distress in patients that have an ICD for primary or secondary prevention of fatal arrhythmias. Methods A multicenter survey of 179 consecutive outpatients (29.1% primary prevention) with ICD implantations completed the Short Form-8 (SF-8), Beck Depression Inventory (BDI), Impact of Event Scale-Revised (IES-R), State-Trait Anxiety Inventory (STAI), and Worries about ICD (WAICD). Results Patients with an ICD for primary prevention had a higher trait anxiety score and worries about ICD score than patients with an ICD for secondary prevention (41.7±12.4 vs. 34.7±12.3, p=0.001 and 39.6±18.0 vs. 30.0±18.9, p=0.002, respectively), even after adjusting for demographic and clinical characteristics. In multivariable analysis of variance, primary prevention ICD recipients reported a poorer QOL on the vitality subscale of the SF-8. Conclusions In our study population, which mostly consisted of New York Heart Association (NYHA) class I and II subjects, primary prevention ICD recipients were more prone to experience worries about their ICD, anxiety, and a poorer QOL compared to secondary prevention ICD recipients. In clinical practice, primary prevention ICD patients should be closely monitored. If warranted, they should be offered psychological intervention, as anxiety and low QOL were predictors of mortality. PMID:27092190
Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun
2016-01-01
Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.
Psychological and clinical problems in young adults with implantable cardioverter-defibrillators.
Wójcicka, Mariola; Lewandowski, Michał; Smolis-Bak, Edyta; Szwed, Hanna
2008-10-01
Implantable cardioverter-defibrillators (ICD) are the most effective treatment in patients with the risk of sudden cardiac death. ICD improves patients' safety but is also the source of numerous inconveniences. Especially young people consider such ICD-related inconveniences as most unwelcome. To assess the quality of life and main psychological problems encountered in young adults with an ICD. We studied 45 subjects aged 14-29 years (mean 21.2+/-4.3). ICDs were used in primary prevention in 22 patients, and in secondary prevention in 23 patients. Time elapsed from implantation ranged from 5 months to 11 years (4.3+/-2.7 years). Since the problems affecting this group were rather specific, the patients' quality of life was assessed with a special questionnaire addressing important issues and problems associated with living with an ICD. ICD discharges were observed in 67.4% of patients (primary prevention - 45.5%, secondary prevention - 82.6%), multiple shocks in 47.2%, and phantom shocks in 21.4%. Anxiety associated with an ICD discharge was reported by 84.4% of patients. In order to prevent ICD discharges, 53.3% of patients decreased their activity. Problems with memory were observed in 42.2% of patients, with concentration in 47.6%, and with sleep in 42.2%. Almost half of those over 18 years of age were active drivers. None of the subjects experienced an ICD discharge during sexual intercourse. None of the men reported any sexual problems, while seven (41.2%) women did. Almost a quarter of the patients claimed to have had complications after the implantation. Young adult patients generally were compliant to have their ICD checked and accepted their limitations and disease. Fewer people assessed their health status as bad. Some patients in the group studied found it extremely difficult to accept their disease and/or ICD and to adapt to the situation. As many as nine patients believed the ICD implantation had been unnecessary, seven did not accept the ICD, three patients thought negatively of follow-up visits, three were not compliant, 13 did not accept the limitations, four refused to accept the fact that their disease existed, and seven refused to do anything. At least four patients talked or thought about having the ICD removed. Patients with ICD have problems in different spheres of their activity (physical, psychological, and social). Such patients need to be informed appropriately about the ICD itself and its functioning. They should be granted psychological support from health professionals who are familiar with the specific problems of ICD recipients.
Köbe, Julia; Hucklenbroich, Katharina; Geisendörfer, Nils; Bettin, Markus; Frommeyer, Gerrit; Reinke, Florian; Dechering, Dirk; Burgmer, Markus; Eckardt, Lars
2017-05-01
For prevention of sudden cardiac death, the transvenously implantable cardioverter-defibrillator therapy (tv-ICD) is well accepted. The subcutaneous system (S-ICD ® ) is promising in terms of reducing ICD complications. Nevertheless, the impact of the novel generator position on patients' quality of life (QoL) is yet unknown. This study aimed at comparing QoL and posttraumatic stress with both systems. 60 S-ICD ® and 60 case-controlled tv single-chamber ICD patients were asked to respond to three standardized questionnaires. PDS [screening for posttraumatic stress disorders (PTSD)] and PHQ-D (detection of the most predominant psychological disorders) were used to screen for potential mental comorbidities. The SF-12 questionnaire was used to evaluate physical and mental well-being. Groups were compared in terms of QoL and PTSD. n = 42 (70%) pairs were analyzed (n = 30 male, mean age 44.6 ± 12.2 years). Prior appropriate (p = 0.06) or inappropriate episodes (p = 0.24), ejection fraction (p = 0.28), or underlying cardiac disease did not differ significantly between groups. PDS revealed a PTSD in n = 6 tv-ICD and n = 6 S-ICD ® patients (14.3%) equally. In the PHQ-D questionnaire, n = 4 tv-ICD and n = 2 S-ICD ® patients fulfilled criteria for a major depression (p = 0.68). Panic disorders (n = 2 tv, n = 0 S-ICD ® , p = 0.5), and anxiety disorders (n = 3 S-ICD ® , n = 0 tv-ICD, p = 0.24) did not differ between groups. The physical well-being score was 39.9 ± 12.5 in patients with a tv-ICD compared to 46.6 ± 9.9 in S-ICD ® patients (p = 0.01). The mental well-being score was comparable in both groups (tv-ICD 51.8 ± 10.8 vs. S-ICD ® 51.9 ± 10.4, p = 0.95). Our case-control study revealed equal or even better physical well-being of patients with the S-ICD ® . PTSD occurred in almost 15% of ICD patients irrespective of the type of system.
Souissi, Zouheir; Guédon-Moreau, Laurence; Boulé, Stéphane; Kouakam, Claude; Finat, Loïc; Marquié, Christelle; Brigadeau, François; Wissocque, Ludivine; Mouton, Stéphanie; Montaigne, David; Klug, Didier; Kacet, Salem; Lacroix, Dominique
2016-06-01
Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
van Barreveld, M; Dijkgraaf, M G W; Hulleman, M; Boersma, L V A; Delnoy, P P H M; Meine, M; Tuinenburg, A E; Theuns, D A M J; van der Voort, P H; Kimman, G P; Buskens, E; Tijssen, J P G; Bruinsma, N; Verstraelen, T E; Zwinderman, A H; van Dessel, P H F M; Wilde, A A M
2017-10-01
Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will eventually receive appropriate ICD therapy. The DO-IT Registry is a nationwide prospective cohort with a target enrolment of 1,500 primary prevention ICD patients with reduced left ventricular function in a setting of structural heart disease. The primary outcome measures are death and appropriate ICD therapy for ventricular tachyarrhythmias. Secondary outcome measures are inappropriate ICD therapy, death of any cause, hospitalisation for ICD related complications and for cardiovascular reasons. As of December 2016, data on demographic, clinical, and ICD characteristics of 1,468 patients have been collected. Follow-up will continue up to 24 months after inclusion of the last patient. During follow-up, clinical and ICD data are collected based on the normal follow-up of these patients, assuming ICD interrogations take place every six months and clinical follow-up is once a year. At baseline, the mean age was 66 (standard deviation [SD] 10) years and 27% were women. The DO-IT Registry represents a real-world nationwide cohort of patients receiving ICDs for primary prevention of sudden cardiac death with reduced left ventricular function in a setting of structural heart disease. The registry investigates the efficacy of the current practice and aims to develop prediction rules to identify subgroups who will not (sufficiently) benefit from ICD implantation and to provide results regarding costs and budget impact of targeted supply of primary preventions ICDs.
Floré, Vincent; Vandenberk, Bert; Belmans, Ann; Garweg, Christophe; Ector, Joris; Willems, Rik
2018-02-01
A new end point called ICD-resistant mortality was evaluated to assess the clinical efficacy of ICD implantations. In 302 ICD patients with ischaemic cardiomyopathy, we investigated which clinical parameters predicted useful ICD implantations using cumulative incidence competing risk analysis. Implantation was deemed clinically useful when the ICD provided appropriate therapy and the patient survived implantation by 1 year and the first shock by 30 days. ICD-resistant mortality (ICDRM) was defined as death within 30 days after the first shock, within 1 year of implantation or without previous appropriate ICD therapy. After 5 years, ICDRM occurred in 23% of implantations, while 36% were clinically useful. After multivariable analysis, ICDRM was associated with LVEF <35% (HR: 2.63; p = .005), beta-blocker dose <50% (HR: 2.0; p = .01) and anterior or diffuse infarct location (HR: 3.61; p = .001 and HR: 2.89; p = .02). Useful ICD implantations were associated with beta-blocker dose <50% (HR: 1.64; p = .02) and non-anterior infarct location (HR: 3.22 vs anterior and 1.59 vs diffuse; combined p<.001). Five years after implantation, an ICD could be classified as useful in 1 out of 3, while ICDRM occurred in one out of four patients. At 10 years, up to 80% of implantations could be categorized. Lower LVEF was related with significantly higher incidence of ICDRM. Anterior infarcts were associated with more ICDRM and less useful implantations than non-anterior infarcts. Future risk stratification for ICD should focus more on the discrimination between arrhythmic risk, probably preventable by ICDs and ICD-resistant mortality risk.
von Gunten, Simon; Schaer, Beat A; Yap, Sing-Chien; Szili-Torok, Tamas; Kühne, Michael; Sticherling, Christian; Osswald, Stefan; Theuns, Dominic A M J
2016-05-01
Longevity of implantable cardioverter defibrillators (ICDs) is crucial for patients and healthcare systems as replacements impact on infection rates and cost-effectiveness. Aim was to determine longevity using very large databases of two teaching hospitals with a high number of replacements and a rather homogeneous distribution among manufacturers. The study population consists of all patients in whom an ICD was inserted in. All ICD manufacturers operating in Switzerland and the Netherlands and all implanted ICDs were included. Implantable cardioverter defibrillator replacements due to normal battery depletion were considered events, and other replacements were censored. Longevity was assessed depending on manufacturers, pacing mode, implant before/after 2006, and all parameters combined. We analysed data from 3436 patients in whom 4881 ICDs [44.2% VVI-ICDs, 27.4% DDD-ICDs, 26.3% cardiac resynchronization therapy (CRT)-ICDs, 2.0% subcutaneous ICDs] were implanted. The four major manufacturers had implant shares between 18.4 and 31.5%. Replacement due to battery depletion (27.4%) was performed for 1339 ICDs. Patient survival at 5 years was 80.1%. Longevity at 5 years improved in contemporary compared with elderly ICDs [63.9-80.6% across all ICDs, of 73.7-92.1% in VVIs, 58.2-76.1% in DDDs, and of 47.1-66.3% in CRT defibrillators, all P value < 0.05]. Remarkable differences were seen among manufacturers, and those with better performance in elderly ICDs were not those with better performance in contemporary ones. Implantable cardioverter defibrillator longevity increased in contemporary models independent of manufacturer and pacing mode. Still, significant differences exist among manufacturers. These results might impact on device selection. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
Resting-state brain networks in patients with Parkinson's disease and impulse control disorders.
Tessitore, Alessandro; Santangelo, Gabriella; De Micco, Rosa; Giordano, Alfonso; Raimo, Simona; Amboni, Marianna; Esposito, Fabrizio; Barone, Paolo; Tedeschi, Gioacchino; Vitale, Carmine
2017-09-01
To investigate intrinsic neural networks connectivity changes in Parkinson's disease (PD) patients with and without impulse control disorders (ICD). Fifteen patients with PD with ICD (ICD+), 15 patients with PD without ICD (ICD-) and 24 age and sex-matched healthy controls (HC) were enrolled in the study. To identify patients with and without ICD and/or punding, we used the Minnesota Impulsive Disorders Interview (MIDI) and a clinical interview based on diagnostic criteria for each symptom. All patients underwent a detailed neuropsychological evaluation. Whole brain structural and functional imaging was performed on a 3T GE MR scanner. Statistical analysis of functional data was completed using BrainVoyager QX software. Voxel-based morphometry (VBM) was used to test whether between-group differences in resting-state connectivity were related to structural abnormalities. The presence of ICD symptoms was associated with an increased connectivity within the salience and default-mode networks, as well as with a decreased connectivity within the central executive network (p < .05 corrected). ICD severity was correlated with both salience and default mode networks connectivity changes only in the ICD+ group. VBM analysis did not reveal any statistically significant differences in local grey matter volume between ICD+ and ICD- patients and between all patients and HC (p < .05. FWE). The presence of a disrupted connectivity within the three core neurocognitive networks may be considered as a potential neural correlate of ICD presence in patients with PD. Our findings provide additional insights into the mechanisms underlying ICD in PD, confirming the crucial role of an abnormal prefrontal-limbic-striatal homeostasis in their development. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nosological status and definition of schizophrenia: Some considerations for DSM-V and ICD-11.
Tandon, Rajiv; Maj, Mario
2008-12-01
Although dementia praecox or schizophrenia has been considered a unique disease entity for the past century, its definitions and boundaries have varied over this period. In this article, we examine the changing conceptualization of schizophrenia over the past 100 years and make some recommendations with regards to its definition in DSM-V and ICD-11. We summarize clinical features of schizophrenia in terms of symptomatology, course, and outcome. We examine factors that lead to changing definitions of a disorder such as schizophrenia, with specific reference to the evolution of its definition from DSM-1 (American Psychiatric Association, Washington, DC, 1952) to the current DSM-IV-TR. Efforts to elucidate the etiology and pathophysiology of schizophrenia have been hampered by its imprecise definition and continuing transformations in its conceptualization. The definition of schizophrenia, at any given time, has been influenced by available diagnostic tools and treatments, other clinical considerations, extant knowledge and scientific paradigms. It is now clear that schizophrenia does not represent a single disease with a unitary etiology or pathogenetic process. Despite limitations in the concept, however, alternative approaches thus far have been unsuccessful in better defining the syndrome of schizophrenia or its component entities. Whereas changing definitions of schizophrenia might impede research into its nature and development of more effective treatments, only a better understanding of schizophrenia can lead to its more precise definition. We consider the implications of our observations for DSM-V and ICD-11 definitions of schizophrenia and summarize some emerging preliminary recommendations. Copyright © 2008 Elsevier B.V. All rights reserved.
Parental alienation, DSM-5, and ICD-11: response to critics.
Bernet, William; Baker, Amy J L
2013-01-01
There has been considerable interest among forensic practitioners in the proposals that parental alienation be included in the next editions of the Diagnostic and Statistical Manual of Mental Diseases (DSM) and The International Classification of Diseases (ICD). However, there has also been a great deal of misunderstanding about the proposals, and misinformation has been expressed in professional meetings, on websites, and in journal articles. In this article we address four common misunderstandings regarding parental alienation: that there is a lack of research to support it as a diagnosis; that adopting parental alienation as a diagnosis will lead to serious adverse consequences; that the advocates of parental alienation are driven by self-serving or malevolent motives; and that Richard Gardner should be criticized for self-publishing his description of parental alienation syndrome.
Ronald, L A; Ling, D I; FitzGerald, J M; Schwartzman, K; Bartlett-Esquilant, G; Boivin, J-F; Benedetti, A; Menzies, D
2017-05-01
An increasing number of studies are using health administrative databases for tuberculosis (TB) research. However, there are limitations to using such databases for identifying patients with TB. To summarise validated methods for identifying TB in health administrative databases. We conducted a systematic literature search in two databases (Ovid Medline and Embase, January 1980-January 2016). We limited the search to diagnostic accuracy studies assessing algorithms derived from drug prescription, International Classification of Diseases (ICD) diagnostic code and/or laboratory data for identifying patients with TB in health administrative databases. The search identified 2413 unique citations. Of the 40 full-text articles reviewed, we included 14 in our review. Algorithms and diagnostic accuracy outcomes to identify TB varied widely across studies, with positive predictive value ranging from 1.3% to 100% and sensitivity ranging from 20% to 100%. Diagnostic accuracy measures of algorithms using out-patient, in-patient and/or laboratory data to identify patients with TB in health administrative databases vary widely across studies. Use solely of ICD diagnostic codes to identify TB, particularly when using out-patient records, is likely to lead to incorrect estimates of case numbers, given the current limitations of ICD systems in coding TB.
Strachan, Patricia H.; de Laat, Sonya; Carroll, Sandra L.; Schwartz, Lisa; Vaandering, Katie; Toor, Gurjit K.; Arthur, Heather M.
2012-01-01
Background Implantable cardioverter defibrillators (ICDs) are increasingly offered to patients for primary prevention of sudden cardiac death. Candidates for ICD receive ICD-related patient education material when they make decisions to consent or decline a primary prevention ICD. Printed patient education material directed at ICD candidates has not been the focus of direct appraisal. Objective We evaluated the readability and content of ICD-related print education materials made available to patients who were enrolled in a study involving patient decision making for ICD from 3 ICD sites in southern Ontario, Canada. Methods All ICD print materials referred to during interviews and/or that were available in ICD site waiting rooms were collected for analysis. Readability testing was conducted using the SMOG (“simple measurement of gobbledygook”) and Fry methods. The material was evaluated according to selected plain-language criteria, thematic content analysis, and rhetoric analysis. Results Twenty-one print materials were identified and analyzed. Documents were authored by device manufacturers, tertiary care hospitals, and cardiac support organizations. Although many documents adhered to plain-language recommendations, text-reading levels were higher than recommended. Twelve major content themes were identified. Content focused heavily on the positive aspects of living with the device to the exclusion of other possible information that could be relevant to the decisions that patients made. Conclusions Print-based patient education materials for ICD candidates are geared to a highly literate population. The focus on positive information to the exclusion of potentially negative aspects of the ICD, or alternatives to accepting 1, could influence and/or confuse patients about the purpose and implications of this medical device. Development of print materials is indicated that includes information about possible problems and that would be relevant for the multicultural and debilitated population who may require ICDs. The findings are highly relevant for nurses who care for primary prevention ICD candidates. PMID:21926915
Essandoh, Michael K; Mark, George E; Aasbo, Johan D; Joyner, Charles A; Sharma, Saumya; Decena, Beningo F; Bolin, Eric D; Weiss, Raul; Burke, Martin C; McClernon, Timothy R; Daoud, Emile G; Gold, Michael R
2018-05-13
Worldwide adoption of the subcutaneous implantable cardioverter-defibrillator (S-ICD) for preventing sudden cardiac death continues to increase, as longer-term evidence demonstrating the safety and efficacy of the S-ICD expands. As a relatively new technology, comprehensive anesthesia guidance for the management of patients undergoing S-ICD placement is lacking. This article presents advantages and disadvantages of different peri-procedural sedation and anesthesia options for S-ICD implants including general anesthesia, monitored anesthesia care, regional anesthesia, and nonanesthesia personnel administered sedation and analgesia. Guidance, for approaches to anesthesia care during S-ICD implantation, are presented based upon literature review and consensus of a panel of high volume S-ICD implanters, a regional anesthesiologist, and a cardiothoracic anesthesiologist with significant S-ICD experience. The panel developed suggested actions for perioperative sedation, anesthesia, surgical practices and a decision algorithm for S-ICD implantation. While S-ICD implantation currently requires higher sedation than transvenous ICD systems, the panel consensus is that general anesthesia is not required or is obligatory for the majority of patients for the experienced S-ICD implanter. The focus of the implanting physician and the anesthesia services should be to maximize patient comfort and take into consideration patient specific co-morbidities, with a low threshold to consult the anesthesiology team. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Development of an expert based ICD-9-CM and ICD-10-CM map to AIS 2005 update 2008.
Loftis, Kathryn L; Price, Janet P; Gillich, Patrick J; Cookman, Kathy J; Brammer, Amy L; St Germain, Trish; Barnes, Jo; Graymire, Vickie; Nayduch, Donna A; Read-Allsopp, Christine; Baus, Katherine; Stanley, Patsye A; Brennan, Maureen
2016-09-01
This article describes how maps were developed from the clinical modifications of the 9th and 10th revisions of the International Classification of Diseases (ICD) to the Abbreviated Injury Scale 2005 Update 2008 (AIS08). The development of the mapping methodology is described, with discussion of the major assumptions used in the process to map ICD codes to AIS severities. There were many intricacies to developing the maps, because the 2 coding systems, ICD and AIS, were developed for different purposes and contain unique classification structures to meet these purposes. Experts in ICD and AIS analyzed the rules and coding guidelines of both injury coding schemes to develop rules for mapping ICD injury codes to the AIS08. This involved subject-matter expertise, detailed knowledge of anatomy, and an in-depth understanding of injury terms and definitions as applied in both taxonomies. The official ICD-9-CM and ICD-10-CM versions (injury sections) were mapped to the AIS08 codes and severities, following the rules outlined in each coding manual. The panel of experts was composed of coders certified in ICD and/or AIS from around the world. In the process of developing the map from ICD to AIS, the experts created rules to address issues with the differences in coding guidelines between the 2 schemas and assure a consistent approach to all codes. Over 19,000 ICD codes were analyzed and maps were generated for each code to AIS08 chapters, AIS08 severities, and Injury Severity Score (ISS) body regions. After completion of the maps, 14,101 (74%) of the eligible 19,012 injury-related ICD-9-CM and ICD-10-CM codes were assigned valid AIS08 severity scores between 1 and 6. The remaining 4,911 codes were assigned an AIS08 of 9 (unknown) or were determined to be nonmappable because the ICD description lacked sufficient qualifying information for determining severity according to AIS rules. There were also 15,214 (80%) ICD codes mapped to AIS08 chapter and ISS body region, which allow for ISS calculations for patient data sets. This mapping between ICD and AIS provides a comprehensive, expert-designed solution for analysts to bridge the data gap between the injury descriptions provided in hospital codes (ICD-9-CM, ICD-10-CM) and injury severity codes (AIS08). By applying consistent rules from both the ICD and AIS taxonomies, the expert panel created these definitive maps, which are the only ones endorsed by the Association for the Advancement of Automotive Medicine (AAAM). Initial validation upheld the quality of these maps for the estimation of AIS severity, but future work should include verification of these maps for MAIS and ISS estimations with large data sets. These ICD-AIS maps will support data analysis from databases with injury information classified in these 2 different systems and open new doors for the investigation of injury from traumatic events using large injury data sets.
Pedersen, Susanne S; Mastenbroek, Mirjam H; Carter, Nathan; Barr, Craig; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D; Boersma, Lucas; Johansen, Jens B; Theuns, Dominic A M J
2016-08-15
The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of life (QoL) is not known. We evaluated the QoL of patients with an S-ICD against an unrelated cohort with a transvenous (TV)-ICD system during 6 months of follow-up. Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system on a priori selected variables including baseline QoL. QoL was measured with the Short-Form Health Survey at baseline, 3, and 6 months after implant and compared using multivariable modeling with repeated measures. Patients with an S-ICD (n = 167) versus a TV-ICD system (n = 167) did not differ significantly on physical (p = 0.8157) and mental QoL scores (p = 0.9080) across baseline, 3, and 6 months after implantation in adjusted analyses. The evolution in physical (p = 0.0503) and mental scores (p = 0.3772) during follow-up was similar for both cohorts, as indicated by the nonsignificant interaction effect for ICD system by time. Both patients with an S-ICD system and a TV-ICD system experienced significant improvements in physical and mental QoL between time of implant and 3 months (both p's <0.0001) and between time of implant and 6 months (both p's <0.0001) but not between 3 and 6 months (both p's >0.05). In conclusion, these first results show that the QoL of patients with an S-ICD versus TV-ICD system is similar and that patients with either system experience improvements in QoL on the short term. Copyright © 2016 Elsevier Inc. All rights reserved.
Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem
2017-06-01
In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.
Physicians’ Knowledge and Attitudes Regarding Implantable Cardioverter- Defibrillators
Sherazi, Saadia; Zareba, Wojciech; Daubert, James P.; McNitt, Scott; Shah, Abrar H.; Aktas, Mehmet K.; Block, Robert C.
2012-01-01
Background Information is limited regarding the knowledge and attitudes of physicians typically involved in the referral of patients for implantable cardioverter defibrillator (ICD) implantation. Methods We conducted a survey of primary care physicians and cardiologists at the University of Rochester Medical Center and the Unity Health System Rochester, NY from December 2008 to February 2009. The survey collected information regarding knowledge and attitudes of physicians towards ICD therapy. Results Of the 332 surveys distributed, 110 (33%) were returned. Over-all 94 (87%) physicians reported referring patients for ICD implantation. Eighteen (17%) physicians reported unawareness of guidelines for ICD use. Sixty-four (59%) physicians recommended ICD in patients with ischemic cardiomyopathy and left ventricular ejection fraction (LVEF) ≤ 35%. Sixty-five (62%) physicians use ≤ 35% as LVEF criteria for ICD referral in patients with non-ischemic cardiomyopathy. Cardiologists were more familiar than primary care physicians with LVEF criteria for implantation of ICD in patients with ischemic and non-ischemic cardiomyopathy (p value 0.005 and 0.002 respectively). Twenty-nine (27%) participants were unsure regarding benefits of ICDs in eligible women and Blacks. Eighty two (76%) physicians believed that an ICD could benefit patients ≥70 years whereas only 53 (49%) indicated that an ICD would benefit patients ≥ 80 years of age. A lack of familiarity with current clinical guidelines regarding ICD implantation exists. Primary care physicians are less aware of clinical guidelines than are cardiologists. This finding highlights the need to improve the dissemination of guidelines to primary care physicians in an effort to improve ICD utilization. PMID:20535717
Vehmeijer, Jim T.; Brouwer, Tom F.; Limpens, Jacqueline; Knops, Reinoud E.; Bouma, Berto J.; Mulder, Barbara J.M.; de Groot, Joris R.
2016-01-01
Aims Sudden cardiac death is a major cause of mortality in adult congenital heart disease (ACHD) patients. The indications for implantable cardioverter-defibrillator (ICD) implantation in ACHD patients are still not well established. We aim to systematically review the literature on indications and outcome of ICD implantation in ACHD patients. Methods and results We performed a comprehensive search in EMBASE, MEDLINE, and Google Scholar to identify all studies on ICD implantation in ACHD patients. We used random effects models to calculate proportions and 95% confidence intervals. Of 1356 articles, 24 studies with 2162 patients were included, with a mean follow-up of 3.6 ± 0.9 years. Half of patients had tetralogy of Fallot. Mean age at implantation was 36.5 ± 5.5 years old and 66% was male. Implantable cardioverter-defibrillators were implanted for primary prevention in 53% (43.5–62.7). Overall, 24% (18.6–31.3) of patients received one or more appropriate ICD interventions (anti-tachycardia pacing or shocks) during 3.7 ± 0.9 years: 22% (16.9–28.8) of patients with primary prevention in 3.3 ± 0.3 years and 35% (26.6–45.2) of patients with secondary prevention in 4.3 ± 1.2 years. Inappropriate shocks occurred in 25% (20.1–31.0) in 3.7 ± 0.8 years and other, particularly lead-related complications in 26% (18.9–33.6) of patients in 3.8 ± 0.8 years. All-cause mortality was 10% during 3.7 ± 0.9 years. Conclusions In ACHD, remarkably high rates of appropriate ICD therapy were reported, both in primary and secondary prevention. Because of the young age and lower death rates, the cumulative beneficial effects are likely greater in ACHD patients than in acquired heart disease patients. However, considering the high rates of inappropriate shocks and complications, case-by-case weighing of costs and benefits, remains essential. PMID:26873095
Impulse Control Disorders: Updated Review of Clinical Characteristics and Pharmacological Management
Schreiber, Liana; Odlaug, Brian L.; Grant, Jon E.
2011-01-01
Impulse control disorders (ICDs) are characterized by urges and behaviors that are excessive and/or harmful to oneself or others and cause significant impairment in social and occupational functioning, as well as legal and financial difficulties. ICDs are relatively common psychiatric conditions, yet are poorly understood by the general public, clinicians, and individuals struggling with the disorder. Although ICD treatment research is limited, studies have shown ICDs may respond well to pharmacological treatment. This article presents a brief overview about the clinical characteristics of ICDs and pharmacological treatment options for individuals with ICDs. PMID:21556272
A computational model for predicting integrase catalytic domain of retrovirus.
Wu, Sijia; Han, Jiuqiang; Zhang, Xinman; Zhong, Dexing; Liu, Ruiling
2017-06-21
Integrase catalytic domain (ICD) is an essential part in the retrovirus for integration reaction, which enables its newly synthesized DNA to be incorporated into the DNA of infected cells. Owing to the crucial role of ICD for the retroviral replication and the absence of an equivalent of integrase in host cells, it is comprehensible that ICD is a promising drug target for therapeutic intervention. However, annotated ICDs in UniProtKB database have still been insufficient for a good understanding of their statistical characteristics so far. Accordingly, it is of great importance to put forward a computational ICD model in this work to annotate these domains in the retroviruses. The proposed model then discovered 11,660 new putative ICDs after scanning sequences without ICD annotations. Subsequently in order to provide much confidence in ICD prediction, it was tested under different cross-validation methods, compared with other database search tools, and verified on independent datasets. Furthermore, an evolutionary analysis performed on the annotated ICDs of retroviruses revealed a tight connection between ICD and retroviral classification. All the datasets involved in this paper and the application software tool of this model can be available for free download at https://sourceforge.net/projects/icdtool/files/?source=navbar. Copyright © 2017 Elsevier Ltd. All rights reserved.
Decision-Making Experiences of Patients with Implantable Cardioverter Defibrillators.
Green, Ariel R; Jenkins, Amy; Masoudi, Frederick A; Magid, David J; Kutner, Jean S; Leff, Bruce; Matlock, Daniel D
2016-10-01
When patients are not adequately engaged in decision making, they may be at risk of decision regret. Our objective was to explore patients' perceptions of their decision-making experiences related to implantable cardioverter defibrillators (ICDs). Cross-sectional, mailed survey of 412 patients who received an ICD without cardiac resynchronization therapy for any indication between 2006 and 2009. Patients were asked about decision participation and decision regret. A total of 295 patients with ICDs responded (72% response rate). Overall, 79% reported that they were as involved in the decision as they wanted. However, 28% reported that they were not told of the option of not getting an ICD and 37% did not remember being asked if they wanted an ICD. In total, 19% reported not wanting their ICD at the time of implantation. Those who did not want the ICD were younger (<65 years; 74% vs 43%, P < 0.001), had higher decision regret (31/100 vs 11/100, P < 0.001), and reported less participation in decision making (the doctor "totally" made the decision, 9% vs 3%; P < 0.001). A considerable number of ICD recipients recalled not wanting their ICD at the time of implantation. While these findings may be prone to recall bias, they likely identify opportunities to improve ICD decision making. © 2016 Wiley Periodicals, Inc.
Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David
2009-06-01
ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.
Trillaud-Doppia, Emilie; Paradis-Isler, Nicolas; Boehm, Jannic
2016-07-01
Alzheimer disease (AD) is initially characterized as a disease of the synapse that affects synaptic transmission and synaptic plasticity. While amyloid-beta and tau have been traditionally implicated in causing AD, recent studies suggest that other factors, such as the intracellular domain of the amyloid-precursor protein (APP-ICD), can also play a role in the development of AD. Here, we show that the expression of APP-ICD induces synaptic depression, while the intracellular domain of its homolog amyloid-like precursor protein 2 (APLP2-ICD) does not. We are able to show that this effect by APP-ICD is due to a single alanine vs. proline difference between APP-ICD and APLP2-ICD. The alanine in APP-ICD and the proline in APLP2-ICD lie directly behind a conserved caspase cleavage site. Inhibition of caspase cleavage of APP-ICD prevents the induction of synaptic depression. Finally, we show that the expression of APP-ICD increases and facilitates long-term depression and blocks induction of long-term potentiation. The block in long-term potentiation can be overcome by mutating the aforementioned alanine in APP-ICD to the proline of APLP2. Based on our results, we propose the emergence of a new APP critical domain for the regulation of synaptic plasticity and in consequence for the development of AD. Copyright © 2016 Elsevier Inc. All rights reserved.
Kobza, Richard; Duru, Firat; Erne, Paul
2008-07-01
Physicians who are caring for patients with implantable cardioverter-defibrillators (ICDs) are regularly confronted with questions concerning daily activities. This study evaluates the habits of ICD patients with respect to sports activities, stays at high-altitude, and driving patterns. A survey was performed in 387 patients with ICDs who were followed at two hospitals in Switzerland. The special-designed questionnaire addressed lifestyle practices concerning sports activity, high-altitude visits, and driving motor vehicles. Fifty-nine percent of ICD patients participated in some kind of sports activity; an ICD shock was experienced in 14% of these patients. Fifty-six percent of the patients reported a stay at high altitudes at least 2,000 m above the sea level; 11% of them stayed regularly above 2,500 m; 4% of these patients experienced an ICD shock during high altitude stay. Seventy-nine percent of the patients drove a motor vehicle; 2% of them experienced an ICD shock during driving, but none of them reported loss of consciousness or a traffic accident. It is accepted that ICD patients disqualify for competitive sports. However, the patients may be encouraged to continue leisure-time physical activities at low-to-moderate intensity. Staying at high altitudes and driving motor vehicles are very rarely associated with ICD shocks. Therefore, these activities that are likely to contribute to a better quality of life should not be discouraged in most ICD recipients in the absence of other medical reasons.
Psychiatric Functioning and Quality of Life in Young Patients With Cardiac Rhythm Devices
Panek, Kathryn A.; Labella, Madelyn; Taylor, George Alexander; Gauvreau, Kimberlee; Cecchin, Frank; Martuscello, Maria; Walsh, Edward P.; Berul, Charles I.; DeMaso, David R.
2014-01-01
BACKGROUND: Less is known about depression, anxiety and quality of life (QoL) in children and adolescents with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) than is known in adults with these devices. METHODS: A standardized psychiatric interview diagnosed anxiety/depressive disorders in a cross-sectional study. Self-report measures of anxiety, depression and post-traumatic stress disorder were obtained. Medical disease severity, family functioning and QoL data were collected. A total of 166 patients were enrolled (52 ICD, 114 PM; median age 15 years). RESULTS: Prevalence of current and lifetime psychiatric disorders was higher in patients with ICDs than PMs (Current: 27% vs. 11%, P = .02; Lifetime: 52% ICD vs. 34% PM, P = .01). Patients with ICDs had more anxiety than a healthy population (25% vs. 7%, P < .01). Patients with ICDs and PMs had similar levels of depression as a healthy population (ICD 10%, PM 4%, reference 4%, P = .29). In multivariate analysis including a medical disease score, demographics, exposure to beta-blockers, activity limitations, hospitalizations, shocks and procedures, the type of device (PM versus ICD) did not predict psychiatric diagnoses when age at implantation and the severity of medical disease were controlled for. Patients with ICDs and PMs had lower physical QoL scores (ICD 45, PM 47.5, Norm 53, P ≤ .03), but similar psychosocial functioning scores (ICD 49, PM 51, Norm 51, P ≥ .16) versus a normal reference population. CONCLUSIONS: Anxiety is highly prevalent in young patients with ICDs, but the higher rates can be attributed to medical disease severity and age at implantation instead of type of device. PMID:24664095
Combining dynamic and ECG-gated ⁸²Rb-PET for practical implementation in the clinic.
Sayre, George A; Bacharach, Stephen L; Dae, Michael W; Seo, Youngho
2012-01-01
For many cardiac clinics, list-mode PET is impractical. Therefore, separate dynamic and ECG-gated acquisitions are needed to detect harmful stenoses, indicate affected coronary arteries, and estimate stenosis severity. However, physicians usually order gated studies only because of dose, time, and cost limitations. These gated studies are limited to detection. In an effort to remove these limitations, we developed a novel curve-fitting algorithm [incomplete data (ICD)] to accurately calculate coronary flow reserve (CFR) from a combined dynamic-ECG protocol of a length equal to a typical gated scan. We selected several retrospective dynamic studies to simulate shortened dynamic acquisitions of the combined protocol and compared (a) the accuracy of ICD and a nominal method in extrapolating the complete functional form of arterial input functions (AIFs); and (b) the accuracy of ICD and ICD-AP (ICD with a-posteriori knowledge of complete-data AIFs) in predicting CFRs. According to the Akaike information criterion, AIFs predicted by ICD were more accurate than those predicted by the nominal method in 11 out of 12 studies. CFRs predicted by ICD and ICD-AP were similar to complete-data predictions (PICD=0.94 and PICD-AP=0.91) and had similar average errors (eICD=2.82% and eICD-AP=2.79%). According to a nuclear cardiologist and an expert analyst of PET data, both ICD and ICD-AP predicted CFR values with sufficient accuracy for the clinic. Therefore, by using our method, physicians in cardiac clinics would have access to the necessary amount of information to differentiate between single-vessel and triple-vessel disease for treatment decision making.
Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurkmans, Coen W.; Scheepers, Egon; Springorum, Bob G.F.
2005-09-01
Purpose: Radiotherapy can influence the functioning of pacemakers and implantable cardioverter-defibrillators (ICDs). ICDs offer the same functionality as pacemakers, but are also able to deliver a high-voltage shock to the heart if needed. Guidelines for radiotherapy treatment of patients with an implanted rhythm device have been published in 1994 by The American Association of Physicists in Medicine, and are based only on experience with pacemakers. Data on the influence of radiotherapy on ICDs are limited. The objective of our study is to determine the influence of radiotherapy on the latest generation of ICDs. Methods and Materials: Eleven modern ICDs havemore » been irradiated in our department. The irradiation was performed with a 6-MV photon beam. The given dose was fractionated up to a cumulative dose of 120 Gy. Two to 5 days passed between consecutive irradiations. Frequency, output, sensing, telemetry, and shock energy were monitored. Results: Sensing interference by ionizing radiation on all ICDs has been demonstrated. For four ICDs, this would have caused the inappropriate delivery of a shock because of interference. At the end of the irradiation sessions, all devices had reached their point of failure. Complete loss of function was observed for four ICDs at dose levels between 0.5 Gy and 1.5 Gy. Conclusions: The effect of radiation therapy on the newest generation of ICDs varies widely. If tachycardia monitoring and therapy are functional (programmed on) during irradiation, the ICD might inappropriately give antitachycardia therapy, often resulting in a shock. Although most ICDs did not fail below 80 Gy, some devices had already failed at doses below 1.5 Gy. Guidelines are formulated for the treatment of patients with an ICD.« less
Deactivation of implantable cardioverter defibrillators in terminal illness and end of life care.
Kirkpatrick, James N; Gottlieb, Maia; Sehgal, Priya; Patel, Rutuke; Verdino, Ralph J
2012-01-01
Cardiology professional societies have recommended that patients with cardiovascular implantable electronic devices complete advance directives (ADs). However, physicians rarely discuss end of life handling of implantable cardioverter defibrillators (ICDs), and standard AD forms do not address the presence of ICDs. We conducted a telephone survey of 278 patients with an ICD from a large, academic hospital. The average period since implantation was 5.15 years. More than 1/3 (38%) had been shocked, with a mean of 4.69 shocks. More than 1/2 had executed an AD, but only 3 had included a plan for their ICD. Most subjects (86%) had never considered what to do with their ICD if they had a serious illness and were unlikely to survive. When asked about ICD deactivation in an end of life situation, 42% said it would depend, 28% favored deactivation, and 11% would not deactivate. One quarter (26%) thought ICD deactivation was a form of assisted suicide, 22% thought a do not resuscitate order did not mean that the ICD should be deactivated, and 46% responded that the ICD should not be automatically deactivated in hospice. The answers did not correlate with any demographic factors. Almost all (95%) agreed that patients should have the opportunity to execute an AD that directs handing of an ICD. When asked who should be responsible for discussing this device for an AD, 31% said electrophysiologists, 45% said general cardiologists, and 14% said primary care physicians. In conclusion, the results of the present study highlight the lack of consensus among patients with an ICD on the issue of deactivation at the end of a patient's life. These findings suggest cardiologists should discuss end of life care and device deactivation with their patients with an ICD. Copyright © 2012 Elsevier Inc. All rights reserved.
[Cause-of-death statistics and ICD, quo vadis?
Eckert, Olaf; Vogel, Ulrich
2018-07-01
The International Statistical Classification of Diseases and Related Health Problems (ICD) is the worldwide binding standard for generating underlying cause-of-death statistics. What are the effects of former revisions of the ICD on underlying cause-of-death statistics and which opportunities and challenges are becoming apparent in a possible transition process from ICD-10 to ICD-11?This article presents the calculation of the exploitation grade of ICD-9 and ICD-10 in the German cause-of-death statistics and quality of documentation. Approximately 67,000 anonymized German death certificates are processed by Iris/MUSE and official German cause-of-death statistics are analyzed.In addition to substantial changes in the exploitation grade in the transition from ICD-9 to ICD-10, regional effects become visible. The rate of so-called "ill-defined" conditions exceeds 10%.Despite substantial improvement of ICD revisions there are long-known deficits in the coroner's inquest, filling death certificates and quality of coding. To make better use of the ICD as a methodological framework for mortality statistics and health reporting in Germany, the following measures are necessary: 1. General use of Iris/MUSE, 2. Establishing multiple underlying cause-of-death statistics, 3. Introduction of an electronic death certificate, 4. Improvement of the medical assessment of cause of death.Within short time the WHO will release the 11th revision of the ICD that will provide additional opportunities for the development of underlying cause-of-death statistics and their use in science, public health and politics. A coordinated effort including participants in the process and users is necessary to meet the related challenges.
A combined coarse-grained and all-atom simulation of TRPV1 channel gating and heat activation
Qin, Feng
2015-01-01
The transient receptor potential (TRP) channels act as key sensors of various chemical and physical stimuli in eukaryotic cells. Despite years of study, the molecular mechanisms of TRP channel activation remain unclear. To elucidate the structural, dynamic, and energetic basis of gating in TRPV1 (a founding member of the TRPV subfamily), we performed coarse-grained modeling and all-atom molecular dynamics (MD) simulation based on the recently solved high resolution structures of the open and closed form of TRPV1. Our coarse-grained normal mode analysis captures two key modes of collective motions involved in the TRPV1 gating transition, featuring a quaternary twist motion of the transmembrane domains (TMDs) relative to the intracellular domains (ICDs). Our transition pathway modeling predicts a sequence of structural movements that propagate from the ICDs to the TMDs via key interface domains (including the membrane proximal domain and the C-terminal domain), leading to sequential opening of the selectivity filter followed by the lower gate in the channel pore (confirmed by modeling conformational changes induced by the activation of ICDs). The above findings of coarse-grained modeling are robust to perturbation by lipids. Finally, our MD simulation of the ICD identifies key residues that contribute differently to the nonpolar energy of the open and closed state, and these residues are predicted to control the temperature sensitivity of TRPV1 gating. These computational predictions offer new insights to the mechanism for heat activation of TRPV1 gating, and will guide our future electrophysiology and mutagenesis studies. PMID:25918362
Socioeconomic and regional differences in the treatment of cervical spondylotic myelopathy
Palejwala, Sheri K.; Rughani, Anand I.; Lemole, G. Michael; Dumont, Travis M.
2017-01-01
Background: Cervical spondylotic myelopathy (CSM) is the leading cause of spinal cord dysfunction in the world. Surgical treatment is both medically and economically advantageous, and can be achieved through multiple approaches, with or without fusion. We used the Nationwide Inpatient Sample (NIS) database to better elucidate regional and socioeconomic variances in the treatment of CSM. Methods: The NIS database was queried for elective admissions with a primary diagnosis of CSM (ICD-9 721.1). This was evaluated for patients who also carried a diagnosis of anterior (ICD-9 81.02) or posterior cervical fusion (ICD-9 81.03), posterior cervical laminectomy (ICD 03.09), or a combination. We then investigated variances including regional trends and disparities according to hospital and insurance types. Results: During 2002–2012, 50605 patients were electively admitted with a diagnosis of CSM. Anterior fusions were more common in Midwestern states and in nonteaching hospitals. Fusion procedures were used more frequently than other treatments in private hospitals and with private insurance. Median hospital charges were also expectedly higher for fusion procedures and combined surgical approaches. Combined approaches were found to be significantly greater in patients with concurrent diagnoses of ossification of the posterior longitudinal ligament (OPLL) and CSM. Ultimately, there has been an increased utilization of fusion procedures versus nonfusion treatments, over the past decade, for patients with cervical myelopathy. Conclusions: Fusion surgery is being increasingly used for the treatment of CSM. Expensive procedures are being performed more frequently in both private hospitals and for those with private insurance, whereas the most economical procedure, posterior cervical laminectomy, was underutilized. PMID:28607826
Cardiac-resynchronization therapy for mild-to-moderate heart failure.
Tang, Anthony S L; Wells, George A; Talajic, Mario; Arnold, Malcolm O; Sheldon, Robert; Connolly, Stuart; Hohnloser, Stefan H; Nichol, Graham; Birnie, David H; Sapp, John L; Yee, Raymond; Healey, Jeffrey S; Rouleau, Jean L
2010-12-16
Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).
NASA Astrophysics Data System (ADS)
Ren, Xueguang; Miteva, Tsveta; Kolorenč, Přemysl; Gokhberg, Kirill; Kuleff, Alexander I.; Cederbaum, Lorenz S.; Dorn, Alexander
2017-09-01
We investigate the interatomic Coulombic decay (ICD) in argon dimers induced by electron-impact ionization (E0=90 eV ) using a multiparticle coincidence experiment in which the momentum vectors and, consequently, the kinetic energies for electrons and fragment ions are determined. The signature of the ICD process is obtained from a correlation map between ejected electron energy and kinetic energy release (KER) for Ar++Ar+ fragment ions where low-energy ICD electrons can be identified. Furthermore, two types of ICD processes, termed fast and slow interatomic decay, are separated by the ICD initial-state energies and projectile energy losses. The dependence of the energies of emitted low-energy ICD electrons on the initial-state energy is studied. ICD electron energy spectra and KER spectra are obtained separately for fast and slow decay processes where the KER spectra for the slow decay channel are strongly influenced by nuclear motion. The KER and ICD electron energy spectra are well reproduced by ab initio calculations.
A Strategic Plan for Integrating ICD-10 in Your Practice and Workflow.
Bowman, Sue; Cleland, Risë Marie; Staggs, Stuart
2015-01-01
The adoption of the International Classification of Disease (ICD) 10th Revision (ICD-10) diagnosis code set in the United States has been legislatively delayed several times with the most recent date for implementation set for October 1, 2015. The transition from ICD-9 to ICD-10 will be a major undertaking that will require a substantial amount of planning. In the following article, we outline the steps to develop and implement a strategic plan for the transition to the new code set, identify training needs throughout the practice, and review the challenges and opportunities associated with the transition to ICD-10.
Zong, W; Wang, P; Leung, B; Moody, G B; Mark, R G
2002-01-01
The advent of implantable cardioverter defibrillators (ICDs) has resulted in significant reductions in mortality in patients at high risk for sudden cardiac death. Extensive related basic research and clinical investigation continue. ICDs typically record intracardiac electrograms and inter-beat intervals along with device settings during episodes of device delivery of therapy. Researchers wishing to study these data further have until now been limited to viewing paper plots. In support of multi-center clinical studies of patients with ICDs, we have developed a web based searchable ICD data archiving system, which allows users to use a web browser to upload ICD data from diskettes to a server where the data are automatically processed and archived. Users can view and download the archived ICD data directly via the web. The entire system is built from open source software. At present more than 500 patient ICD data sets have been uploaded to and archived in the system. This project will be of value not only to those who wish to conduct research using ICD data, but also to clinicians who need to archive and review ICD data collected from their patients.
Open-access programs for injury categorization using ICD-9 or ICD-10.
Clark, David E; Black, Adam W; Skavdahl, David H; Hallagan, Lee D
2018-04-09
The article introduces Programs for Injury Categorization, using the International Classification of Diseases (ICD) and R statistical software (ICDPIC-R). Starting with ICD-8, methods have been described to map injury diagnosis codes to severity scores, especially the Abbreviated Injury Scale (AIS) and Injury Severity Score (ISS). ICDPIC was originally developed for this purpose using Stata, and ICDPIC-R is an open-access update that accepts both ICD-9 and ICD-10 codes. Data were obtained from the National Trauma Data Bank (NTDB), Admission Year 2015. ICDPIC-R derives CDC injury mechanism categories and an approximate ISS ("RISS") from either ICD-9 or ICD-10 codes. For ICD-9-coded cases, RISS is derived similar to the Stata package (with some improvements reflecting user feedback). For ICD-10-coded cases, RISS may be calculated in several ways: The "GEM" methods convert ICD-10 to ICD-9 (using General Equivalence Mapping tables from CMS) and then calculate ISS with options similar to the Stata package; a "ROCmax" method calculates RISS directly from ICD-10 codes, based on diagnosis-specific mortality in the NTDB, maximizing the C-statistic for predicting NTDB mortality while attempting to minimize the difference between RISS and ISS submitted by NTDB registrars (ISSAIS). Findings were validated using data from the National Inpatient Survey (NIS, 2015). NTDB contained 917,865 cases, of which 86,878 had valid ICD-10 injury codes. For a random 100,000 ICD-9-coded cases in NTDB, RISS using the GEM methods was nearly identical to ISS calculated by the Stata version, which has been previously validated. For ICD-10-coded cases in NTDB, categorized ISS using any version of RISS was similar to ISSAIS; for both NTDB and NIS cases, increasing ISS was associated with increasing mortality. Prediction of NTDB mortality was associated with C-statistics of 0.81 for ISSAIS, 0.75 for RISS using the GEM methods, and 0.85 for RISS using the ROCmax method; prediction of NIS mortality was associated with C-statistics of 0.75-0.76 for RISS using the GEM methods, and 0.78 for RISS using the ROCmax method. Instructions are provided for accessing ICDPIC-R at no cost. The ideal methods of injury categorization and injury severity scoring involve trained personnel with access to injured persons or their medical records. ICDPIC-R may be a useful substitute when this ideal cannot be obtained.
Comparison of Three Information Sources for Smoking Information in Electronic Health Records
Wang, Liwei; Ruan, Xiaoyang; Yang, Ping; Liu, Hongfang
2016-01-01
OBJECTIVE The primary aim was to compare independent and joint performance of retrieving smoking status through different sources, including narrative text processed by natural language processing (NLP), patient-provided information (PPI), and diagnosis codes (ie, International Classification of Diseases, Ninth Revision [ICD-9]). We also compared the performance of retrieving smoking strength information (ie, heavy/light smoker) from narrative text and PPI. MATERIALS AND METHODS Our study leveraged an existing lung cancer cohort for smoking status, amount, and strength information, which was manually chart-reviewed. On the NLP side, smoking-related electronic medical record (EMR) data were retrieved first. A pattern-based smoking information extraction module was then implemented to extract smoking-related information. After that, heuristic rules were used to obtain smoking status-related information. Smoking information was also obtained from structured data sources based on diagnosis codes and PPI. Sensitivity, specificity, and accuracy were measured using patients with coverage (ie, the proportion of patients whose smoking status/strength can be effectively determined). RESULTS NLP alone has the best overall performance for smoking status extraction (patient coverage: 0.88; sensitivity: 0.97; specificity: 0.70; accuracy: 0.88); combining PPI with NLP further improved patient coverage to 0.96. ICD-9 does not provide additional improvement to NLP and its combination with PPI. For smoking strength, combining NLP with PPI has slight improvement over NLP alone. CONCLUSION These findings suggest that narrative text could serve as a more reliable and comprehensive source for obtaining smoking-related information than structured data sources. PPI, the readily available structured data, could be used as a complementary source for more comprehensive patient coverage. PMID:27980387
Hong, KyungPyo; Jeong, Eun-Kee; Wall, T. Scott; Drakos, Stavros G.; Kim, Daniel
2015-01-01
Purpose To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). Methods We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz), in order to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5T. Results In 5 phantoms representing native myocardium and blood and post-contrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error >29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error <5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error >10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error <2.0%). Conclusion This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. PMID:25975192
Patel, Nileshkumar J; Edla, Sushruth; Deshmukh, Abhishek; Nalluri, Nikhil; Patel, Nilay; Agnihotri, Kanishk; Patel, Achint; Savani, Chirag; Patel, Nish; Bhimani, Ronak; Thakkar, Badal; Arora, Shilpkumar; Asti, Deepak; Badheka, Apurva O; Parikh, Valay; Mitrani, Raul D; Noseworthy, Peter; Paydak, Hakan; Viles-Gonzalez, Juan; Friedman, Paul A; Kowalski, Marcin
2016-02-01
Prior studies have highlighted disparities in cardiac lifesaving procedure utilization, particularly among women and in minorities. Although there has been a significant increase in implantable cardioverter-defibrillator (ICD) insertion, socioeconomic disparities still exist in the trend of ICD utilization. With the use of the Nationwide Inpatient Sample from 2003 through 2011, we identified subjects with ICD insertion (procedure code 37.94) and cardiac resynchronization defibrillator (procedure code 00.50, 00.51) as codified by the International Classification of Diseases, Ninth Revision, Clinical Modification. Overall, 1 020 076 ICDs were implanted in the United States from 2003 to 2011. We observed an initial increase in ICD utilization by 51%, from 95 062 in 2003 to 143 262 in 2006, followed by a more recent decline. The majority of ICDs were implanted in men age ≥65 years. Implantation of ICDs was 2.5× more common in men than in women (402 per million vs 163 per million). Approximately 95% of the ICDs were implanted in insured patients, and 5% were used in the uninsured population. There has been a significant increase in ICD implantation in blacks, from 162 per million in 2003 to 291 per million in 2011. We found a significant difference in the volume of ICD implants between the insured and the uninsured patient populations. Racial disparities have narrowed significantly in comparison with those noted in earlier studies and are now more reflective of the population demographics at large. On the other hand, significant gender disparities continue to exist. © 2016 Wiley Periodicals, Inc.
Venepalli, Neeta K; Qamruzzaman, Yusuf; Li, Jianrong John; Lussier, Yves A; Boyd, Andrew D
2014-03-01
To quantify coding ambiguity in International Classification of Diseases Ninth Revision Clinical Modification conversions (ICD-9-CM) to ICD-10-CM mappings for hematology-oncology diagnoses within an Illinois Medicaid database and an academic cancer center database (University of Illinois Cancer Center [UICC]) with the goal of anticipating challenges during ICD-10-CM transition. One data set of ICD-9-CM diagnosis codes came from the 2010 Illinois Department of Medicaid, filtered for diagnoses generated by hematology-oncology providers. The other data set of ICD-9-CM diagnosis codes came from UICC. Using a translational methodology via the Motif Web portal ICD-9-CM conversion tool, ICD-9-CM to ICD-10-CM code conversions were graphically mapped and evaluated for clinical loss of information. The transition to ICD-10-CM led to significant information loss, affecting 8% of total Medicaid codes and 1% of UICC codes; 39 ICD-9-CM codes with information loss accounted for 2.9% of total Medicaid reimbursements and 5.3% of UICC billing charges. Prior work stated hematology-oncology would be the least affected medical specialty. However, information loss affecting 5% of billing costs could evaporate the operating margin of a practice. By identifying codes at risk for complex transitions, the analytic tools described can be replicated for oncology practices to forecast areas requiring additional training and resource allocation. In summary, complex transitions and diagnosis codes associated with information loss within clinical oncology require additional attention during the transition to ICD-10-CM.
Thomas, Kevin L; Zimmer, Louise O; Dai, David; Al-Khatib, Sana M; Allen LaPointe, Nancy M; Peterson, Eric D
2013-07-01
Black individuals eligible for an implantable cardioverter/defibrillator (ICD) are considerably less likely than white individuals to receive one. This disparity may, in part, be explained by racial differences in patient preferences. We hypothesized that a targeted patient-centered educational video could improve knowledge of sudden cardiac arrest (SCA) and ICDs and reduce racial differences in ICD preferences. We conducted a pilot study to assess the feasibility of testing this hypothesis in a randomized trial. We created a video that included animation, physician commentary, and patient testimonials on SCA and ICDs. The primary outcome was the decision to have an ICD implanted as a function of race and intervention. Between January 1, 2011, and December 31, 2011, 59 patients (37 white and 22 black) were randomized to the video or health care provider counseling/usual care. Relative to white patients, black patients were younger (median age, 55 vs 68 years) and more likely to have attended college or technical school. Baseline SCA and ICD knowledge was similar and improved significantly in both racial groups after the intervention. Black patients viewing the video were as likely as white patients to want an ICD (60.0% vs 79.2%, P = .20); and among those in the usual care arm, black patients were less likely than white patients to want an ICD (42.9% vs 84.6% P = .05). Among individuals eligible for an ICD, a video decision aid increased patient knowledge and reduced racial differences in patient preference for an ICD. Copyright © 2013 Mosby, Inc. All rights reserved.
Cinovský, K; Skodácek, Igor
2008-02-01
This paper studies the contribution of anxiety in origin of functional behavioural disorders of children. The intense sensing of anxiety attributes to the shaping of one's personality. Adaptation and adjustment, accommodation and assimilation to stressful conditions producing anxiety are analyzed. There are diagnosed reactions of organism to the circumstances of the CAN syndrome and trauma. In these circumstances, a primary perception of reality is at stake that consequently leads to sociopathological features. This paper also provides the authors' opinions of psychoanalytical and behavioural schools on origin of personal decompensation and neurotic disorders. Causes of panic disorder and other diseases, in which a stress trauma plays a role, are considered. For these reasons the authors suggest classifying the CAN syndrome as a separate nosologic unit in the future ICD-11.
Dollars and sense: Mitigating budget risk for ICD-10.
Newell, Lucy Mancini; DeSilva, Joseph J
2013-02-01
The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.
Caillet, P; Oberlin, P; Monnet, E; Guillon-Grammatico, L; Métral, P; Belhassen, M; Denier, P; Banaei-Bouchareb, L; Viprey, M; Biau, D; Schott, A-M
2017-10-01
Osteoporotic hip fractures (OHF) are associated with significant morbidity and mortality. The French medico-administrative database (SNIIRAM) offers an interesting opportunity to improve the management of OHF. However, the validity of studies conducted with this database relies heavily on the quality of the algorithm used to detect OHF. The aim of the REDSIAM network is to facilitate the use of the SNIIRAM database. The main objective of this study was to present and discuss several OHF-detection algorithms that could be used with this database. A non-systematic literature search was performed. The Medline database was explored during the period January 2005-August 2016. Furthermore, a snowball search was then carried out from the articles included and field experts were contacted. The extraction was conducted using the chart developed by the REDSIAM network's "Methodology" task force. The ICD-10 codes used to detect OHF are mainly S72.0, S72.1, and S72.2. The performance of these algorithms is at best partially validated. Complementary use of medical and surgical procedure codes would affect their performance. Finally, few studies described how they dealt with fractures of non-osteoporotic origin, re-hospitalization, and potential contralateral fracture cases. Authors in the literature encourage the use of ICD-10 codes S72.0 to S72.2 to develop algorithms for OHF detection. These are the codes most frequently used for OHF in France. Depending on the study objectives, other ICD10 codes and medical and surgical procedures could be usefully discussed for inclusion in the algorithm. Detection and management of duplicates and non-osteoporotic fractures should be considered in the process. Finally, when a study is based on such an algorithm, all these points should be precisely described in the publication. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Lamb, Mary K; Innes, Kerry; Saad, Patricia; Rust, Julie; Dimitropoulos, Vera; Cumerlato, Megan
The Performance Indicators for Coding Quality (PICQ) is a data quality assessment tool developed by Australia's National Centre for Classification in Health (NCCH). PICQ consists of a number of indicators covering all ICD-10-AM disease chapters, some procedure chapters from the Australian Classification of Health Intervention (ACHI) and some Australian Coding Standards (ACS). The indicators can be used to assess the coding quality of hospital morbidity data by monitoring compliance of coding conventions and ACS; this enables the identification of particular records that may be incorrectly coded, thus providing a measure of data quality. There are 31 obstetric indicators available for the ICD-10-AM Fourth Edition. Twenty of these 31 indicators were classified as Fatal, nine as Warning and two Relative. These indicators were used to examine coding quality of obstetric records in the 2004-2005 financial year Australian national hospital morbidity dataset. Records with obstetric disease or procedure codes listed anywhere in the code string were extracted and exported from the SPSS source file. Data were then imported into a Microsoft Access database table as per PICQ instructions, and run against all Fatal and Warning and Relative (N=31) obstetric PICQ 2006 Fourth Edition Indicators v.5 for the ICD-10- AM Fourth Edition. There were 689,905 gynaecological and obstetric records in the 2004-2005 financial year, of which 1.14% were found to have triggered Fatal degree errors, 3.78% Warning degree errors and 8.35% Relative degree errors. The types of errors include completeness, redundancy, specificity and sequencing problems. It was found that PICQ is a useful initial screening tool for the assessment of ICD-10-AM/ACHI coding quality. The overall quality of codes assigned to obstetric records in the 2004- 2005 Australian national morbidity dataset is of fair quality.
Jilek, Clemens; Tzeis, Stylianos; Reents, Tilko; Estner, Heidi-Luise; Fichtner, Stephanie; Ammar, Sonia; Wu, Jinjin; Hessling, Gabriele; Deisenhofer, Isabel; Kolb, Christof
2010-10-01
Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices. A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St. Louis, MO, USA) at the maximal magnetic field strength of 0.1 Tesla and evaluated in vitro with respect to changes in parameter settings of the device, changes of the battery status/detection of elective replacement indication, or alterations of data stored in the device. A total of 115 out of 121 (95%) devices were free of changes in parameter settings, battery status, and internally stored data after repeated exposition to the electromagnetic field of the remote magnetic navigation system. Interference with the magnetic navigation field was observed in 6 pacemakers, resulting in reprogramming to a power-on-reset mode with or without detection of the elective replacement indication in 5 devices and abnormal variance of battery status in one device. All pacemakers could be reprogrammed to the initial modes and the battery status proved to be normal some minutes after the pacemakers had been removed from the magnetic field. Interference of a remote magnetic navigation system (at maximal field strength) with pacemakers and ICDs not connected to leads with antitachycardic detection and therapies turned off is rare. Occurring functional abnormalities could be reprogrammed in our sample. An in vitro study will give information about interference of devices connected to leads. © 2010 Wiley Periodicals, Inc.
Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio
2011-01-01
A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.
Horwood, Laura; Attili, Anil; Luba, Frank; Ibrahim, El-Sayed H; Parmar, Hemant; Stojanovska, Jadranka; Gadoth-Goodman, Sharon; Fette, Carey; Oral, Hakan; Bogun, Frank
2017-05-01
Magnetic resonance imaging (MRI) has been reported to be safe in patients with cardiac implantable electronic devices (CIED) provided a specific protocol is followed. The objective of this study was to assess whether this is also true for patients excluded from published protocols. A total of 160 MRIs were obtained in 142 consecutive patients with CIEDs [106 patients had an implantable cardioverter defibrillator (ICD) and 36 had a pacemaker implanted] using an adapted, pre-specified protocol. A cardiac MRI was performed in 95 patients, and a spinal/brain MRI was performed in 47 patients. Forty-six patients (32%) had either abandoned leads (n = 10), and/or were pacemaker dependent with an implanted ICD (n = 19), had recently implanted CIEDs (n = 1), and/or had a CIED device with battery depletion (n = 2), and/or a component of the CIED was recalled or on advisory (n = 32). No major complications occurred. Some device parameters changed slightly, but significantly, right after or at 1-week post-MRI without requiring any reprogramming. In one patient with an ICD on advisory, the pacing rate changed inexplicably during one of his two MRIs from 90 to 50 b.p.m. Using a pre-specified protocol, cardiac and non-cardiac MRIs were performed in CIED patients with pacemaker dependency, abandoned leads, or depleted batteries without occurrence of major adverse events. Patients with devices on advisory need to be monitored carefully during MRI, especially if they are pacemaker dependent. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Lubinski, Andrzej; Bissinger, Andrzej; Boersma, Lucas; Leenhardt, Antoine; Merkely, Bela; Oto, Ali; Proclemer, Alessandro; Brugada, Josep; Vardas, Panos E; Wolpert, Christian
2011-05-01
Sudden cardiac death (SCD) is a major health concern in developed countries. Many studies have demonstrated the efficacy of implantable cardioverter defibrillator (ICD) therapy in the prevention of SCD and total mortality reduction. However, the high individual costs and the reimbursement policy may limit widespread ICD utilization. This study analyzed the temporal and the geographical trends of the ICD implantation rate. Data were gathered from two editions of the European Heart Rhythm Association (EHRA) White Books published in 2008 and 2009. The analysis revealed significant differences in the rates of ICD implantation per million capita between the countries, but the median implantations was constantly increasing. The number of ICD implantations correlated with gross domestic product (GDP), GDP per capita, expenditure on health, life expectancy, and the number of implanting centres. There are great number of differences in the ICD-implanting rates between EHRA member countries, consequent to the increase in the number of ICD implantations. The ICD implantation rates are related to national economic status and healthcare expenses.
Augmentation and impulsive behaviors in restless legs syndrome: Coexistence or association?
Heim, Beatrice; Djamshidian, Atbin; Heidbreder, Anna; Stefani, Ambra; Zamarian, Laura; Pertl, Marie-Theres; Brandauer, Elisabeth; Delazer, Margarete; Seppi, Klaus; Poewe, Werner; Högl, Birgit
2016-07-05
To assess the frequency of impulse control disorders (ICDs) in patients with restless legs syndrome (RLS) with and without augmentation under dopaminergic therapy in a case-control study. Augmentation and ICDs are both serious complications of dopaminergic treatment of RLS but little is known about possible associations between these drug-induced disorders. In total, 58 patients with idiopathic RLS diagnosed according to the International Restless Legs Syndrome Study Group criteria were recruited. Of these, 35 patients had augmentation. The frequency of ICD symptoms was assessed using semi-structural interviews. Demographic variables did not differ between patients with RLS with and without augmentation but those with augmentation took higher dopaminergic medication than patients without augmentation. Twenty-three patients with RLS (39.7%) had ICD symptoms, with 12 patients (20.7%) having definitive ICDs. Patients with augmentation had an increased risk of expressing ICD symptoms (p = 0.007, odds ratio 5.64, 95% confidence interval 1.59-20.02). Patients with RLS with augmentation have an almost 6-fold increased risk of exhibiting ICD symptoms. This implies that augmentation and ICDs are related and may share a common pathophysiology. Moreover, our results have clinical implications, suggesting that patients with RLS with augmentation should be screened for ICD symptoms. © 2016 American Academy of Neurology.
Iowa Gambling Task Performance in Parkinson Disease Patients with Impulse Control Disorders.
Biars, Julia W; Johnson, Nicole L; Nespeca, Michelle; Busch, Robyn M; Kubu, Cynthia S; Floden, Darlene P
2018-04-27
A subgroup of patients with Parkinson disease (PD) develops impulse control disorders (ICD) associated with their dopamine replacement therapy. Patients and their families may be reluctant to report ICD symptoms or unaware these symptoms are related to PD medication, which can make detecting an ICD difficult for clinicians. Ideally, a behavioral measure that is sensitive to ICD could be employed to ensure that patients with these behaviors are identified and treated. The Iowa Gambling Task (IGT), a standardized decision-making task, has proven sensitive in other populations with impulse control problems. We hypothesized that the IGT would differentiate between PD patients with and without ICD. We compared IGT performance and disease variables in 24 PD patients with ICD and 24 PD patients without ICD. Patient groups were matched in terms of age, sex, and duration of PD. There were no significant differences in IGT scores between PD groups. IGT performance declined with increasing age, but the majority of patients performed within normal limits based on published age- and education-corrected normative data. The IGT did not distinguish between PD patients with and without ICD. Increasing age negatively impacted performance in both groups. Other studies have found that IGT performance may decline in normal aging. Our results suggest that the IGT lacks the sensitivity and specificity needed to differentiate between age-related deficits and disruption in frontal-subcortical circuits underlying ICD associated with PD medications. Therefore, the IGT is not an appropriate behavioral measure for ICD in PD patients.
Simard, Marc; Sirois, Caroline; Candas, Bernard
2018-05-01
To validate and compare performance of an International Classification of Diseases, tenth revision (ICD-10) version of a combined comorbidity index merging conditions of Charlson and Elixhauser measures against individual measures in the prediction of 30-day mortality. To select a weight derivation method providing optimal performance across ICD-9 and ICD-10 coding systems. Using 2 adult population-based cohorts of patients with hospital admissions in ICD-9 (2005, n=337,367) and ICD-10 (2011, n=348,820), we validated a combined comorbidity index by predicting 30-day mortality with logistic regression. To appreciate performance of the Combined index and both individual measures, factors impacting indices performance such as population characteristics and weight derivation methods were accounted for. We applied 3 scoring methods (Van Walraven, Schneeweiss, and Charlson) and determined which provides best predictive values. Combined index [c-statistics: 0.853 (95% confidence interval: CI, 0.848-0.856)] performed better than original Charlson [0.841 (95% CI, 0.835-0.844)] or Elixhauser [0.841 (95% CI, 0.837-0.844)] measures on ICD-10 cohort. All weight derivation methods provided close high discrimination results for the Combined index (Van Walraven: 0.852, Schneeweiss: 0.851, Charlson: 0.849). Results were consistent across both coding systems. The Combined index remains valid with both ICD-9 and ICD-10 coding systems and the 3 weight derivation methods evaluated provided consistent high performance across those coding systems.
Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis
2017-11-01
Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.
Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples
Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask
2015-01-01
Background In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. Objectives and method The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. Results The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. Conclusions The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria. PMID:26450830
Oosthuizen, GV; Sartorius, B; Keene, C; Clarke, DL
2014-01-01
Introduction Intercostal chest drain (ICD) insertion is a commonly performed procedure in trauma and may be associated with significant morbidity. Methods This was a retrospective review of ICD complications in a major trauma service in South Africa over a four-year period from January 2010 to December 2013. Results A total of 1,050 ICDs were inserted in 1,006 patients, of which 91% were male. The median patient age was 24 years (interquartile range [IQR]: 20–29 years). There were 962 patients with unilateral ICDs and 44 with bilateral ICDs. Seventy-five per cent (758/1,006) sustained penetrating trauma and the remaining 25% (248/1006) sustained blunt trauma. Indications for ICD insertion were: haemopneumothorax (n=338), haemothorax (n=314), simple pneumothorax (n=265), tension pneumothorax (n=79) and open pneumothorax (n=54). Overall, 203 ICDs (19%) were associated with complications: 18% (36/203) were kinked, 18% (36/203) were inserted subcutaneously, 13% (27/203) were too shallow and in 7% (14/203) there was inadequate fixation resulting in dislodgement. Four patients (2%) sustained visceral injuries and two sustained vascular injuries. Forty-one per cent (83/203) were inserted outside the ‘triangle of safety’ but without visceral or vascular injuries. One patient had the ICD inserted on the wrong side. Junior doctors inserted 798 ICDs (76%) while senior doctors inserted 252 (24%). Junior doctors had a significantly higher complication rate (24%) compared with senior doctors (5%) (p<0.001). There was no mortality as a direct result of ICD insertion. Conclusions ICD insertion is associated with a high rate of complications. These complications are significantly higher when junior doctors perform the procedure. A multifaceted quality improvement programme is needed to improve the situation. PMID:25350185
Kong, V Y; Oosthuizen, G V; Sartorius, B; Keene, C; Clarke, D L
2014-11-01
Intercostal chest drain (ICD) insertion is a commonly performed procedure in trauma and may be associated with significant morbidity. This was a retrospective review of ICD complications in a major trauma service in South Africa over a four-year period from January 2010 to December 2013. A total of 1,050 ICDs were inserted in 1,006 patients, of which 91% were male. The median patient age was 24 years (interquartile range [IQR]: 20-29 years). There were 962 patients with unilateral ICDs and 44 with bilateral ICDs. Seventy-five per cent (758/1,006) sustained penetrating trauma and the remaining 25% (248/1006) sustained blunt trauma. Indications for ICD insertion were: haemopneumothorax (n=338), haemothorax (n=314), simple pneumothorax (n=265), tension pneumothorax (n=79) and open pneumothorax (n=54). Overall, 203 ICDs (19%) were associated with complications: 18% (36/203) were kinked, 18% (36/203) were inserted subcutaneously, 13% (27/203) were too shallow and in 7% (14/203) there was inadequate fixation resulting in dislodgement. Four patients (2%) sustained visceral injuries and two sustained vascular injuries. Forty-one per cent (83/203) were inserted outside the 'triangle of safety' but without visceral or vascular injuries. One patient had the ICD inserted on the wrong side. Junior doctors inserted 798 ICDs (76%) while senior doctors inserted 252 (24%). Junior doctors had a significantly higher complication rate (24%) compared with senior doctors (5%) (p<0.001). There was no mortality as a direct result of ICD insertion. Conclusions ICD insertion is associated with a high rate of complications. These complications are significantly higher when junior doctors perform the procedure. A multifaceted quality improvement programme is needed to improve the situation.
La Greca, Annette M.; Danzi, BreAnne A.; Chan, Sherilynn F.
2017-01-01
ABSTRACT Background: Major revisions have been made to the DSM and ICD models of post-traumatic stress disorder (PTSD). However, it is not known whether these models fit children’s post-trauma responses, even though children are a vulnerable population following disasters. Objective: Using data from Hurricane Ike, we examined how well trauma-exposed children’s symptoms fit the DSM-IV, DSM-5 and ICD-11 models, and whether the models varied by gender. We also evaluated whether elevated symptoms of depression and anxiety characterized children meeting PTSD criteria based on DSM-5 and ICD-11. Method: Eight-months post-disaster, children (N = 327, 7–11 years) affected by Hurricane Ike completed measures of PTSD, anxiety and depression. Algorithms approximated a PTSD diagnosis based on DSM-5 and ICD-11 models. Results: Using confirmatory factor analysis, ICD-11 had the best-fitting model, followed by DSM-IV and DSM-5. The ICD-11 model also demonstrated strong measurement invariance across gender. Analyses revealed poor overlap between DSM-5 and ICD-11, although children meeting either set of criteria reported severe PTSD symptoms. Further, children who met PTSD criteria for DSM-5, but not for ICD-11, reported significantly higher levels of depression and general anxiety than children not meeting DSM-5 criteria. Conclusions: Findings support the parsimonious ICD-11 model of PTSD for trauma-exposed children, although adequate fit also was obtained for DSM-5. Use of only one model of PTSD, be it DSM-5 or ICD-11, will likely miss children with significant post-traumatic stress. DSM-5 may identify children with high levels of comorbid symptomatology, which may require additional clinical intervention. PMID:28451076
La Greca, Annette M; Danzi, BreAnne A; Chan, Sherilynn F
2017-01-01
Background : Major revisions have been made to the DSM and ICD models of post-traumatic stress disorder (PTSD). However, it is not known whether these models fit children's post-trauma responses, even though children are a vulnerable population following disasters. Objective : Using data from Hurricane Ike, we examined how well trauma-exposed children's symptoms fit the DSM-IV, DSM-5 and ICD-11 models, and whether the models varied by gender. We also evaluated whether elevated symptoms of depression and anxiety characterized children meeting PTSD criteria based on DSM-5 and ICD-11. Method : Eight-months post-disaster, children ( N = 327, 7-11 years) affected by Hurricane Ike completed measures of PTSD, anxiety and depression. Algorithms approximated a PTSD diagnosis based on DSM-5 and ICD-11 models. Results : Using confirmatory factor analysis, ICD-11 had the best-fitting model, followed by DSM-IV and DSM-5. The ICD-11 model also demonstrated strong measurement invariance across gender. Analyses revealed poor overlap between DSM-5 and ICD-11, although children meeting either set of criteria reported severe PTSD symptoms. Further, children who met PTSD criteria for DSM-5, but not for ICD-11, reported significantly higher levels of depression and general anxiety than children not meeting DSM-5 criteria. Conclusions : Findings support the parsimonious ICD-11 model of PTSD for trauma-exposed children, although adequate fit also was obtained for DSM-5. Use of only one model of PTSD, be it DSM-5 or ICD-11, will likely miss children with significant post-traumatic stress. DSM-5 may identify children with high levels of comorbid symptomatology, which may require additional clinical intervention.
Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples.
Hansen, Maj; Hyland, Philip; Armour, Cherie; Shevlin, Mark; Elklit, Ask
2015-01-01
In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), the symptom profile of posttraumatic stress disorder (PTSD) was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11) that includes just six symptoms. The objectives of the current study are: 1) to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746) using confirmatory factor analysis; 2) to assess the concurrent validity of the ICD-11 model of PTSD; and 3) to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria.
Validation of ICD-9 Codes for Stable Miscarriage in the Emergency Department.
Quinley, Kelly E; Falck, Ailsa; Kallan, Michael J; Datner, Elizabeth M; Carr, Brendan G; Schreiber, Courtney A
2015-07-01
International Classification of Disease, Ninth Revision (ICD-9) diagnosis codes have not been validated for identifying cases of missed abortion where a pregnancy is no longer viable but the cervical os remains closed. Our goal was to assess whether ICD-9 code "632" for missed abortion has high sensitivity and positive predictive value (PPV) in identifying patients in the emergency department (ED) with cases of stable early pregnancy failure (EPF). We studied females ages 13-50 years presenting to the ED of an urban academic medical center. We approached our analysis from two perspectives, evaluating both the sensitivity and PPV of ICD-9 code "632" in identifying patients with stable EPF. All patients with chief complaints "pregnant and bleeding" or "pregnant and cramping" over a 12-month period were identified. We randomly reviewed two months of patient visits and calculated the sensitivity of ICD-9 code "632" for true cases of stable miscarriage. To establish the PPV of ICD-9 code "632" for capturing missed abortions, we identified patients whose visits from the same time period were assigned ICD-9 code "632," and identified those with actual cases of stable EPF. We reviewed 310 patient records (17.6% of 1,762 sampled). Thirteen of 31 patient records assigned ICD-9 code for missed abortion correctly identified cases of stable EPF (sensitivity=41.9%), and 140 of the 142 patients without EPF were not assigned the ICD-9 code "632"(specificity=98.6%). Of the 52 eligible patients identified by ICD-9 code "632," 39 cases met the criteria for stable EPF (PPV=75.0%). ICD-9 code "632" has low sensitivity for identifying stable EPF, but its high specificity and moderately high PPV are valuable for studying cases of stable EPF in epidemiologic studies using administrative data.
Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F; Cheng, Alan
2014-08-01
Implantable cardioverter-defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African Americans (AAs). The purpose of this study was to determine the association between AA race and outcomes in a cohort of primary prevention ICD patients. We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end-point was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary end-point was all-cause mortality. There were 1189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratio (95% confidence interval) comparing AAs vs non-AAs were 1.24 (0.96-1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1%-69.5%), 18.7% (5.3%-58.0%), and 13.6% (3.8%-53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remaining unexplained. In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Boveda, Serge; Lenarczyk, Radoslaw; Haugaa, Kristina; Fumagalli, Stefano; Madrid, Antonio Hernandez; Defaye, Pascal; Broadhurst, Paul; Dagres, Nikolaos
2016-09-01
The purpose of this European Heart Rhythm Association (EHRA) survey is to provide an overview of the current use of subcutaneous cardioverter defibrillators (S-ICDs) across a broad range of European centres. A questionnaire was sent via the internet to centres participating in the EHRA electrophysiology research network. Questions included standards of care and policies used for patient management, indications, and techniques of implantation of the S-ICDs. In total, 52 centres replied to the questionnaire. More than one-fourth of the responding centres does not implant the S-ICD (n = 14, 27%). The majority reported to have implanted <10 (50%) or 10-29 (23%) S-ICDs during the last 12 months. Lack of reimbursement (25%), non-availability (19%), and cost of the device (25%) seem to limit the use of the S-ICD. The most commonly reported indications for S-ICD implantation are a difficult vascular access (82%), a history of previous complicated transvenous ICD (8O%), young age (69%), or an anticipated higher risk of infection (63%). Inappropriate therapies were the most frequently reported major problems (38%), but the majority of respondents (51%) never encountered any issue after an S-ICD implantation. Most of the respondents (83%) anticipate significant increase of S-ICD use within the next 2 years. This survey provides a contemporary insight into S-ICD implantation and management in the European electrophysiology centres, showing different approaches, depending on local policies. Cost issues or lack of reimbursement strongly influence the dissemination of the device. However, most respondents retain that S-ICD use will significantly increase in a very short time. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Cheng, Alan; Zhang, Yiyi; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Ellenbogen, Kenneth A; Dickfeld, Timm; Spragg, David D; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F
2014-12-01
Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. clinicaltrials.gov; Unique Identifier: NCT00733590. © 2014 American Heart Association, Inc.
Sabbag, Avi; Suleiman, Mahmoud; Laish-Farkash, Avishag; Samania, Nimer; Kazatsker, Mark; Goldenberg, Ilan; Glikson, Michael; Beinart, Roy
2015-12-01
Implantable cardioverter-defibrillators (ICDs) have become the mainstay of preventive measures for sudden cardiac death (SCD). However, there are limited data on rates of appropriate life-saving ICD shock therapies in contemporary real-life settings. The purpose of the study was to evaluate the rate of appropriate life-saving ICD shock therapies in a contemporary registry. The Israeli ICD Registry includes all implants and other ICD operative procedures nationwide. The present study comprises 2349 consecutive cases who were enrolled in the Registry and prospectively followed up for information regarding survival, hospitalizations, and ICD therapies since 2010. Kaplan-Meier survival analysis showed that the rate of appropriate ICD shock therapy at 30-month follow-up was 2.6% among patients who received an ICD for primary prevention compared with 7.4% among those who received a device for secondary prevention (log-rank P < .001). Rates of appropriate ICD shocks among primary prevention patients were 1.1% at 1-year of follow-up and 2.6% at 30 months, whereas the corresponding rates in the secondary prevention group were 3.8% at 1 year and 7.4% at 30 months (log-rank P < .001). A total of 253 patients (4.8%) died during follow-up, 65% of noncardiac causes. Rates of life-saving appropriate ICD shock therapies among patients implanted with a defibrillator for the primary prevention of SCD in a contemporary real-world setting are lower than reported previously. These findings suggest a need for improved risk stratification and patient selection in this population. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.
Weems, Shelley; Heller, Pamela; Fenton, Susan H
2015-01-01
The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.
Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study
Weems, Shelley; Heller, Pamela; Fenton, Susan H.
2015-01-01
The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity.Coder training and type of record (inpatient versus outpatient) affect coding productivity.Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity. PMID:26396553
Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R
2018-02-23
Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Boyd, Andrew D; ‘John’ Li, Jianrong; Kenost, Colleen; Joese, Binoy; Min Yang, Young; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A
2015-01-01
In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as “convoluted” by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: “identity” (reciprocal), “class-to-subclass,” “subclass-to-class,” “convoluted,” or “no mapping.” These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible. Web portal: http://www.lussierlab.org/transition-to-ICD9CM/ Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9 PMID:25681260
Chatterjee, Neal A; Roka, Attila; Lubitz, Steven A; Gold, Michael R; Daubert, Claude; Linde, Cecilia; Steffel, Jan; Singh, Jagmeet P; Mela, Theofanie
2015-11-01
For patients undergoing cardiac resynchronization therapy (CRT) with implantable cardioverter-defibrillator (ICD; CRT-D), the effect of an improvement in left ventricular ejection fraction (LVEF) on appropriate ICD therapy may have significant implications regarding management at the time of ICD generator replacement. We conducted a meta-analysis to determine the effect of LVEF recovery following CRT on the incidence of appropriate ICD therapy. A search of multiple electronic databases identified 709 reports, of which 6 retrospective cohort studies were included (n = 1740). In patients with post-CRT LVEF ≥35% (study n = 4), the pooled estimated rate of ICD therapy (5.5/100 person-years) was significantly lower than patients with post-CRT LVEF <35% [incidence rate difference (IRD): -6.5/100 person-years, 95% confidence interval (95% CI): -8.8 to -4.2, P < 0.001]. Similarly, patients with post-CRT LVEF ≥45% (study n = 4) demonstrated lower estimated rates of ICD therapy (2.3/100 person-years) compared with patients without such recovery (IRD: -5.8/100 person-years, 95% CI: -7.6 to -4.0, P < 0.001). Restricting analysis to studies discounting ICD therapies during LVEF recovery (study n = 3), patients with LVEF recovery (≥35 or ≥45%) had significantly lower rates of ICD therapy compared with patients without such recovery (P for both <0.001). Patients with primary prevention indication for ICD, regardless of LVEF recovery definition, had very low rates of ICD therapy (0.4 to 0.8/100-person years). Recovery of LVEF post-CRT is associated with significantly reduced appropriate ICD therapy. Patients with improvement of LVEF ≥45% and those with primary prevention indication for ICD appear to be at lowest risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Leveraging the NLM map from SNOMED CT to ICD-10-CM to facilitate adoption of ICD-10-CM.
Cartagena, F Phil; Schaeffer, Molly; Rifai, Dorothy; Doroshenko, Victoria; Goldberg, Howard S
2015-05-01
Develop and test web services to retrieve and identify the most precise ICD-10-CM code(s) for a given clinical encounter. Facilitate creation of user interfaces that 1) provide an initial shortlist of candidate codes, ideally visible on a single screen; and 2) enable code refinement. To satisfy our high-level use cases, the analysis and design process involved reviewing available maps and crosswalks, designing the rule adjudication framework, determining necessary metadata, retrieving related codes, and iteratively improving the code refinement algorithm. The Partners ICD-10-CM Search and Mapping Services (PI-10 Services) are SOAP web services written using Microsoft's.NET 4.0 Framework, Windows Communications Framework, and SQL Server 2012. The services cover 96% of the Partners problem list subset of SNOMED CT codes that map to ICD-10-CM codes and can return up to 76% of the 69,823 billable ICD-10-CM codes prior to creation of custom mapping rules. We consider ways to increase 1) the coverage ratio of the Partners problem list subset of SNOMED CT codes and 2) the upper bound of returnable ICD-10-CM codes by creating custom mapping rules. Future work will investigate the utility of the transitive closure of SNOMED CT codes and other methods to assist in custom rule creation and, ultimately, to provide more complete coverage of ICD-10-CM codes. ICD-10-CM will be easier for clinicians to manage if applications display short lists of candidate codes from which clinicians can subsequently select a code for further refinement. The PI-10 Services support ICD-10 migration by implementing this paradigm and enabling users to consistently and accurately find the best ICD-10-CM code(s) without translation from ICD-9-CM. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
KILLINGSWORTH, CHERYL R.; MELNICK, SHARON B.; LITOVSKY, SILVIO H.; IDEKER, RAYMOND E.; WALCOTT, GREGORY P.
2013-01-01
Background A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. Methods During sinus rhythm, anesthetized pigs (38±6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24-hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semi-quantitative scoring. Results Troponin I was significantly elevated at 4- and 24-hours (22.6±16.3 and 3.1±1.3 ng/ml; baseline 0.07±0.09 ng/ml) in control pigs but not in S-ICD pigs (0.12±0.11 and 0.13±0.13 ng/ml; baseline 0.06±0.03 ng/ml). CK-MM was significantly elevated in S-ICD pigs after shocks (6544±1496 and 9705±6240 U/L; baseline 704±398 U/L) but not in controls. ECG changes occurred post-shock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Conclusion Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. PMID:23713608
Rattanaumpawan, Pinyo; Wongkamhla, Thanyarak; Thamlikitkul, Visanu
2016-04-01
To determine the accuracy of International Statistical Classification of Disease and Related Health Problems, 10th Revision (ICD-10) coding system in identifying comorbidities and infectious conditions using data from a Thai university hospital administrative database. A retrospective cross-sectional study was conducted among patients hospitalized in six general medicine wards at Siriraj Hospital. ICD-10 code data was identified and retrieved directly from the hospital administrative database. Patient comorbidities were captured using the ICD-10 coding algorithm for the Charlson comorbidity index. Infectious conditions were captured using the groups of ICD-10 diagnostic codes that were carefully prepared by two independent infectious disease specialists. Accuracy of ICD-10 codes combined with microbiological dataf or diagnosis of urinary tract infection (UTI) and bloodstream infection (BSI) was evaluated. Clinical data gathered from chart review was considered the gold standard in this study. Between February 1 and May 31, 2013, a chart review of 546 hospitalization records was conducted. The mean age of hospitalized patients was 62.8 ± 17.8 years and 65.9% of patients were female. Median length of stay [range] was 10.0 [1.0-353.0] days and hospital mortality was 21.8%. Conditions with ICD-10 codes that had good sensitivity (90% or higher) were diabetes mellitus and HIV infection. Conditions with ICD-10 codes that had good specificity (90% or higher) were cerebrovascular disease, chronic lung disease, diabetes mellitus, cancer HIV infection, and all infectious conditions. By combining ICD-10 codes with microbiological results, sensitivity increased from 49.5 to 66%for UTI and from 78.3 to 92.8%for BS. The ICD-10 coding algorithm is reliable only in some selected conditions, including underlying diabetes mellitus and HIV infection. Combining microbiological results with ICD-10 codes increased sensitivity of ICD-10 codes for identifying BSI. Future research is needed to improve the accuracy of hospital administrative coding system in Thailand.
Van Belleghem, Griet; Devos, Stefanie; De Wit, Liesbet; Hubloue, Ives; Lauwaert, Door; Pien, Karen; Putman, Koen
2016-01-01
Injury severity scores are important in the context of developing European and national goals on traffic safety, health-care benchmarking and improving patient communication. Various severity scores are available and are mostly based on Abbreviated Injury Scale (AIS) or International Classification of Diseases (ICD). The aim of this paper is to compare the predictive value for in-hospital mortality between the various severity scores if only International Classification of Diseases, 9th revision, Clinical Modification ICD-9-CM is reported. To estimate severity scores based on the AIS lexicon, ICD-9-CM codes were converted with ICD Programmes for Injury Categorization (ICDPIC) and four AIS-based severity scores were derived: Maximum AIS (MaxAIS), Injury Severity Score (ISS), New Injury Severity Score (NISS) and Exponential Injury Severity Score (EISS). Based on ICD-9-CM, six severity scores were calculated. Determined by the number of injuries taken into account and the means by which survival risk ratios (SRRs) were calculated, four different approaches were used to calculate the ICD-9-based Injury Severity Scores (ICISS). The Trauma Mortality Prediction Model (TMPM) was calculated with the ICD-9-CM-based model averaged regression coefficients (MARC) for both the single worst injury and multiple injuries. Severity scores were compared via model discrimination and calibration. Model comparisons were performed separately for the severity scores based on the single worst injury and multiple injuries. For ICD-9-based scales, estimation of area under the receiver operating characteristic curve (AUROC) ranges between 0.94 and 0.96, while AIS-based scales range between 0.72 and 0.76, respectively. The intercept in the calibration plots is not significantly different from 0 for MaxAIS, ICISS and TMPM. When only ICD-9-CM codes are reported, ICD-9-CM-based severity scores perform better than severity scores based on the conversion to AIS. Copyright © 2015 Elsevier Ltd. All rights reserved.
Simulation of ICD-9 to ICD-10-CM Transition for Family Medicine: Simple or Convoluted?
Grief, Samuel N; Patel, Jesal; Kochendorfer, Karl M; Green, Lee A; Lussier, Yves A; Li, Jianrong; Burton, Michael; Boyd, Andrew D
2016-01-01
The objective of this study was to examine the impact of the transition from International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM), to Interactional Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM), on family medicine and to identify areas where additional training might be required. Family medicine ICD-9-CM codes were obtained from an Illinois Medicaid data set (113,000 patient visits and $5.5 million in claims). Using the science of networks, we evaluated each ICD-9-CM code used by family medicine physicians to determine whether the transition was simple or convoluted. A simple transition is defined as 1 ICD-9-CM code mapping to 1 ICD-10-CM code, or 1 ICD-9-CM code mapping to multiple ICD-10-CM codes. A convoluted transition is where the transitions between coding systems is nonreciprocal and complex, with multiple codes for which definitions become intertwined. Three family medicine physicians evaluated the most frequently encountered complex mappings for clinical accuracy. Of the 1635 diagnosis codes used by family medicine physicians, 70% of the codes were categorized as simple, 27% of codes were convoluted, and 3% had no mapping. For the visits, 75%, 24%, and 1% corresponded with simple, convoluted, and no mapping, respectively. Payment for submitted claims was similarly aligned. Of the frequently encountered convoluted codes, 3 diagnosis codes were clinically incorrect, but they represent only <0.1% of the overall diagnosis codes. The transition to ICD-10-CM is simple for 70% or more of diagnosis codes, visits, and reimbursement for a family medicine physician. However, some frequently used codes for disease management are convoluted and incorrect, and for which additional resources need to be invested to ensure a successful transition to ICD-10-CM. © Copyright 2016 by the American Board of Family Medicine.
Simulation of ICD-9 to ICD-10-CM transition for family medicine: simple or convoluted?
Grief, Samuel N.; Patel, Jesal; Lussier, Yves A.; Li, Jianrong; Burton, Michael; Boyd, Andrew D.
2017-01-01
Objectives The objective of this study was to examine the impact of the transition from International Classification of Disease Version Nine Clinical Modification (ICD-9-CM) to Interactional Classification of Disease Version Ten Clinical Modification (ICD-10-CM) on family medicine and identify areas where additional training might be required. Methods Family medicine ICD-9-CM codes were obtained from an Illinois Medicaid data set (113,000 patient visits and $5.5 million dollars in claims). Using the science of networks we evaluated each ICD-9-CM code used by family medicine physicians to determine if the transition was simple or convoluted.1 A simple translation is defined as one ICD-9-CM code mapping to one ICD-10-CM code or one ICD-9-CM code mapping to multiple ICD-10-CM codes. A convoluted transition is where the transitions between coding systems is non-reciprocal and complex with multiple codes where definitions become intertwined. Three family medicine physicians evaluated the most frequently encountered complex mappings for clinical accuracy. Results Of the 1635 diagnosis codes used by the family medicine physicians, 70% of the codes were categorized as simple, 27% of the diagnosis codes were convoluted and 3% were found to have no mapping. For the visits, 75%, 24%, and 1% corresponded with simple, convoluted, and no mapping, respectively. Payment for submitted claims were similarly aligned. Of the frequently encountered convoluted codes, 3 diagnosis codes were clinically incorrect, but they represent only < 0.1% of the overall diagnosis codes. Conclusions The transition to ICD-10-CM is simple for 70% or more of diagnosis codes, visits, and reimbursement for a family medicine physician. However, some frequently used codes for disease management are convoluted and incorrect, where additional resources need to be invested to ensure a successful transition to ICD-10-CM. PMID:26769875
Sharma, Ashish; Goyal, Vinay; Behari, Madhuri; Srivastva, Achal; Shukla, Garima; Vibha, Deepti
2015-01-01
There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs) in Indian patients with Parkinson's Disease (PD). In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated "Questionnaire for Impulsive-Compulsive Disorders in Parkinson's disease (QUIP)" and to examine their association with Dopamine replacement therapy (DRT). This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver) were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%), at least one Impulse control disorder (ICD) was present in 74 (24.75%) and at least one Impulse control related compulsive behaviour (ICRB) was present in 93 (31.1%) patients. Punding was the most frequent (12.4%) followed by hyper sexuality (11.04%), compulsive hobbyism (9.4%), compulsive shopping (8.4%), compulsive medication use (7.7%), compulsive eating (5.35%), walkabout (4%) and pathological gambling (3.3%). ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD) were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Our study revealed a relatively higher frequency of ICD-RBs, probably because of the use of screening instrument and because we combined both ICDs and ICRBs. Also high proportion of DA use (81.6%) among our patients might be responsible. The role of genetic factors that might increase the risk of developing ICD-RBs in this population needs further exploration.
Heart failure severity, inappropriate ICD therapy, and novel ICD programming: a MADIT-RIT substudy.
Daimee, Usama A; Vermilye, Katherine; Rosero, Spencer; Schuger, Claudio D; Daubert, James P; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Moss, Arthur J; Kutyifa, Valentina
2017-12-01
The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P < 0.001) and CRT-D patients (HR = 3.73, CI: 1.14-12.23, P = 0.030). This was consistent for inappropriate ATP and inappropriate ICD therapy < 200 beats/min, but not for inappropriate shocks. Novel ICD programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P < 0.001; Arm C vs Arm A: HR = 0.17, P < 0.001) and NYHA I-II (Arm B vs Arm A: HR = 0.25, P < 0.001; Arm C vs Arm A: HR = 0.28, P < 0.001). Patients with more severe HF are at increased risk for inappropriate ICD therapy, particularly ATP due to arrhythmias < 200 beats/min. Novel programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF. © 2017 Wiley Periodicals, Inc.
Zonfrillo, Mark R; Weaver, Ashley A; Gillich, Patrick J; Price, Janet P; Stitzel, Joel D
2015-01-01
There has been a longstanding desire for a map to convert International Classification of Diseases (ICD) injury codes to Abbreviated Injury Scale (AIS) codes to reflect the severity of those diagnoses. The Association for the Advancement of Automotive Medicine (AAAM) was tasked by European Union representatives to create a categorical map classifying diagnoses codes as serious injury (Abbreviated Injury Scale [AIS] 3+), minor/moderate injury (AIS 1/2), or indeterminate. This study's objective was to map injury-related ICD-9-CM (clinical modification) and ICD-10-CM codes to these severity categories. Approximately 19,000 ICD codes were mapped, including injuries from the following categories: amputations, blood vessel injury, burns, crushing injury, dislocations/sprains/strains, foreign body, fractures, internal organ, nerve/spinal cord injury, intracranial, laceration, open wounds, and superficial injury/contusion. Two parallel activities were completed to create the maps: (1) An in-person expert panel and (2) an electronic survey. The panel consisted of expert users of AIS and ICD from North America, the United Kingdom, and Australia. The panel met in person for 5 days, with follow-up virtual meetings to create and revise the maps. Additional qualitative data were documented to resolve potential discrepancies in mapping. The electronic survey was completed by 95 injury coding professionals from North America, Spain, Australia, and New Zealand over 12 weeks. ICD-to-AIS maps were created for: ICD-9-CM and ICD-10-CM. Both maps indicated whether the corresponding AIS 2005/Update 2008 severity score for each ICD code was AIS 3+, 1/2, or indeterminable. Though some ICD codes could be mapped to multiple AIS codes, the maximum severity of all potentially mapped injuries determined the final severity categorization. The in-person panel consisted of 13 experts, with 11 Certified AIS specialists (CAISS) with a median of 8 years and an average of 15 years of coding experience. Consensus was reached for AIS severity categorization for all injury-related ICD codes. There were 95 survey respondents, with a median of 8 years of injury coding experience. Approximately 15 survey responses were collected per ICD code. Results from the 2 activities were compared, and any discrepancies were resolved using additional qualitative and quantitative data from the in-person panel and survey results, respectively. Robust maps of ICD-9-CM and ICD-10-CM injury codes to AIS severity categories (3+ versus <3) were successfully created from an in-person panel discussion and electronic survey. These maps provide a link between the common ICD diagnostic lexicons and the AIS severity coding system and are of value to injury researchers, public health scientists, and epidemiologists using large databases without available AIS coding.
Wegmann, Elisa; Brand, Matthias
2016-01-01
Online communication applications such as Facebook, WhatsApp, and Twitter are some of the most frequently used Internet applications. There is a growing amount of individuals suffering diminished control over their use of online communication applications which leads to diverse negative consequences in offline life. This could be referred to as Internet-communication disorder (ICD). The current study investigates the role of individual characteristics (e.g., psychopathological symptoms, feelings of loneliness) and specific cognitions. In a sample of 485 participants a structural equation model was tested to investigate predictors and mediators which may predict an excessive use. The results emphasize that a higher level of social loneliness and less perceived social support enhance the risk of a pathological use. The effects of psychopathological symptoms (depression and social anxiety) as well as individual characteristics (self-esteem, self-efficacy, and stress vulnerability) on ICD symptoms are mediated by Internet-use expectancies and dysfunctional coping mechanisms. The results illustrate mediation effects which are in line with the theoretical model by Brand et al. (2016). As suggested in the model social aspects seem to be key predictors of ICD symptoms. Further research should investigate convergent and divergent factors of other types of specific Internet-use disorders. PMID:27891107
NASA Astrophysics Data System (ADS)
Bostock, J.; Weller, P.; Cooklin, M.
2010-07-01
Automated diagnostic algorithms are used in implantable cardioverter-defibrillators (ICD's) to detect abnormal heart rhythms. Algorithms misdiagnose and improved specificity is needed to prevent inappropriate therapy. Knowledge engineering (KE) and artificial intelligence (AI) could improve this. A pilot study of KE was performed with artificial neural network (ANN) as AI system. A case note review analysed arrhythmic events stored in patients ICD memory. 13.2% patients received inappropriate therapy. The best ICD algorithm had sensitivity 1.00, specificity 0.69 (p<0.001 different to gold standard). A subset of data was used to train and test an ANN. A feed-forward, back-propagation network with 7 inputs, a 4 node hidden layer and 1 output had sensitivity 1.00, specificity 0.71 (p<0.001). A prospective study was performed using KE to list arrhythmias, factors and indicators for which measurable parameters were evaluated and results reviewed by a domain expert. Waveforms from electrodes in the heart and thoracic bio-impedance; temperature and motion data were collected from 65 patients during cardiac electrophysiological studies. 5 incomplete datasets were due to technical failures. We concluded that KE successfully guided selection of parameters and ANN produced a usable system and that complex data collection carries greater risk of technical failure, leading to data loss.
Isothermal chemical denaturation of large proteins: Path-dependence and irreversibility.
Wafer, Lucas; Kloczewiak, Marek; Polleck, Sharon M; Luo, Yin
2017-12-15
State functions (e.g., ΔG) are path independent and quantitatively describe the equilibrium states of a thermodynamic system. Isothermal chemical denaturation (ICD) is often used to extrapolate state function parameters for protein unfolding in native buffer conditions. The approach is prudent when the unfolding/refolding processes are path independent and reversible, but may lead to erroneous results if the processes are not reversible. The reversibility was demonstrated in several early studies for smaller proteins, but was assumed in some reports for large proteins with complex structures. In this work, the unfolding/refolding of several proteins were systematically studied using an automated ICD instrument. It is shown that: (i) the apparent unfolding mechanism and conformational stability of large proteins can be denaturant-dependent, (ii) equilibration times for large proteins are non-trivial and may introduce significant error into calculations of ΔG, (iii) fluorescence emission spectroscopy may not correspond to other methods, such as circular dichroism, when used to measure protein unfolding, and (iv) irreversible unfolding and hysteresis can occur in the absence of aggregation. These results suggest that thorough confirmation of the state functions by, for example, performing refolding experiments or using additional denaturants, is needed when quantitatively studying the thermodynamics of protein unfolding using ICD. Copyright © 2017 Elsevier Inc. All rights reserved.
Wegmann, Elisa; Brand, Matthias
2016-01-01
Online communication applications such as Facebook, WhatsApp, and Twitter are some of the most frequently used Internet applications. There is a growing amount of individuals suffering diminished control over their use of online communication applications which leads to diverse negative consequences in offline life. This could be referred to as Internet-communication disorder (ICD). The current study investigates the role of individual characteristics (e.g., psychopathological symptoms, feelings of loneliness) and specific cognitions. In a sample of 485 participants a structural equation model was tested to investigate predictors and mediators which may predict an excessive use. The results emphasize that a higher level of social loneliness and less perceived social support enhance the risk of a pathological use. The effects of psychopathological symptoms (depression and social anxiety) as well as individual characteristics (self-esteem, self-efficacy, and stress vulnerability) on ICD symptoms are mediated by Internet-use expectancies and dysfunctional coping mechanisms. The results illustrate mediation effects which are in line with the theoretical model by Brand et al. (2016). As suggested in the model social aspects seem to be key predictors of ICD symptoms. Further research should investigate convergent and divergent factors of other types of specific Internet-use disorders.
Sideris, Costas; Alshurafa, Nabil; Pourhomayoun, Mohammad; Shahmohammadi, Farhad; Samy, Lauren; Sarrafzadeh, Majid
2015-01-01
In this paper, we propose a novel methodology for utilizing disease diagnostic information to predict severity of condition for Congestive Heart Failure (CHF) patients. Our methodology relies on a novel, clustering-based, feature extraction framework using disease diagnostic information. To reduce the dimensionality we identify disease clusters using cooccurence frequencies. We then utilize these clusters as features to predict patient severity of condition. We build our clustering and feature extraction algorithm using the 2012 National Inpatient Sample (NIS), Healthcare Cost and Utilization Project (HCUP) which contains 7 million discharge records and ICD-9-CM codes. The proposed framework is tested on Ronald Reagan UCLA Medical Center Electronic Health Records (EHR) from 3041 patients. We compare our cluster-based feature set with another that incorporates the Charlson comorbidity score as a feature and demonstrate an accuracy improvement of up to 14% in the predictability of the severity of condition.
Medical Surveillance Monthly Report (MSMR). Volume 13, Number 2, February/March 2007
2007-03-01
13/No. 2 1 10 100 1,000 10,000 100,000 Influenza Varicella Hep B Pertussis Hep A Mumps Meningococcal disease Vaccine-preventable disease R ep or te... pertussis (ICD- 9: 033), mumps (ICD-9: 072), influenza (ICD-9: 487), hepatitis B (ICD-9: 070.2, 070.3), and hepatitis A (ICD- 9: 070.0, 070.1) were defined by...Influenza Varicella Hep B w/o coma Pertussis Hep A w/o coma MSMR 17Vol. 13/No. 2 conditions should account for potential changes in case ascertainment and
Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper
2018-04-01
An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.
Fundamental Research on Infrared Detection
2006-10-15
2. Antimony-based type-II superlattice (T2-SL) photodetectors – We explored the temperature dependent and noise current characteristics of interband...their CZT substrates. Task 2. Antimony-based type-II superlattice (T2-SL) photodetectors – We explored the temperature dependent and noise ...structures, leading to potentially high device performance in photovoltaic mode with low noise and normal incidence detection. The ICDs have a
Gasparini, Maurizio; Galimberti, Paola; Bragato, Renato; Ghio, Stefano; Raineri, Claudia; Landolina, Maurizio; Chieffo, Enrico; Lunati, Maurizio; Mulargia, Ederina; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Vicentini, Alessandro; Marcantoni, Lina; Zanon, Francesco; Klersy, Catherine
2016-12-03
Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.
Cell death and immunity in cancer: From danger signals to mimicry of pathogen defense responses.
Garg, Abhishek D; Agostinis, Patrizia
2017-11-01
The immunogenicity of cancer cells is an emerging determinant of anti-cancer immunotherapy. Beyond developing immunostimulatory regimens like dendritic cell-based vaccines, immune-checkpoint blockers, and adoptive T-cell transfer, investigators are beginning to focus on the immunobiology of dying cancer cells and its relevance for the success of anticancer immunotherapies. It is currently accepted that cancer cells may die in response to anti-cancer therapies through regulated cell death programs, which may either repress or increase their immunogenic potential. In particular, the induction of immunogenic cancer cell death (ICD), which is hallmarked by the emission of damage-associated molecular patterns (DAMPs); molecules analogous to pathogen-associated molecular patterns (PAMPs) acting as danger signals/alarmins, is of great relevance in cancer therapy. These ICD-associated danger signals favor immunomodulatory responses that lead to tumor-associated antigens (TAAs)-directed T-cell immunity, which paves way for the removal of residual, treatment-resistant cancer cells. It is also emerging that cancer cells succumbing to ICD can orchestrate "altered-self mimicry" i.e. mimicry of pathogen defense responses, on the levels of nucleic acids and/or chemokines (resulting in type I interferon/IFN responses or pathogen response-like neutrophil activity). In this review, we exhaustively describe the main molecular, immunological, preclinical, and clinical aspects of immunosuppressive cell death or ICD (with respect to apoptosis, necrosis and necroptosis). We also provide an extensive historical background of these fields, with special attention to the self/non-self and danger models, which have shaped the field of cell death immunology. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fisher, Brian T; Harris, Tracey; Torp, Kari; Seif, Alix E; Shah, Ami; Huang, Yuan-Shung V; Bailey, L Charles; Kersun, Leslie S; Reilly, Anne F; Rheingold, Susan R; Walker, Dana; Li, Yimei; Aplenc, Richard
2014-01-01
Acute lymphoblastic leukemia (ALL) accounts for almost one quarter of pediatric cancer in the United States. Despite cooperative group therapeutic trials, there remains a paucity of large cohort data on which to conduct epidemiology and comparative effectiveness research studies. We designed a 3-step process utilizing International Classification of Diseases-9 Clinical Modification (ICD-9) discharge diagnoses codes and chemotherapy exposure data contained in the Pediatric Health Information System administrative database to establish a cohort of children with de novo ALL. This process was validated by chart review at 1 of the pediatric centers. An ALL cohort of 8733 patients was identified with a sensitivity of 88% [95% confidence interval (CI), 83%-92%] and a positive predictive value of 93% (95% CI, 89%-96%). The 30-day all cause inpatient case fatality rate using this 3-step process was 0.80% (95% CI, 0.63%-1.01%), which was significantly different than the case fatality rate of 1.40% (95% CI, 1.23%-1.60%) when ICD-9 codes alone were used. This is the first report of assembly and validation of a cohort of de novo ALL patients from a database representative of free-standing children's hospitals across the United States. Our data demonstrate that the use of ICD-9 codes alone to establish cohorts will lead to substantial patient misclassification and result in biased outcome estimates. Systematic methods beyond the use of just ICD-9 codes must be used before analysis to establish accurate cohorts of patients with malignancy. A similar approach should be followed when establishing future cohorts from administrative data.
Infant Mortality: Development of a Proposed Update to the Dollfus Classification of Infant Deaths
Dove, Melanie S.; Minnal, Archana; Damesyn, Mark; Curtis, Michael P.
2015-01-01
Objective Identifying infant deaths with common underlying causes and potential intervention points is critical to infant mortality surveillance and the development of prevention strategies. We constructed an International Classification of Diseases 10th Revision (ICD-10) parallel to the Dollfus cause-of-death classification scheme first published in 1990, which organized infant deaths by etiology and their amenability to prevention efforts. Methods Infant death records for 1996, dual-coded to the ICD Ninth Revision (ICD-9) and ICD-10, were obtained from the CDC public-use multiple-cause-of-death file on comparability between ICD-9 and ICD-10. We used the underlying cause of death to group 27,821 infant deaths into the nine categories of the ICD-9-based update to Dollfus' original coding scheme, published by Sowards in 1999. Comparability ratios were computed to measure concordance between ICD versions. Results The Dollfus classification system updated with ICD-10 codes had limited agreement with the 1999 modified classification system. Although prematurity, congenital malformations, Sudden Infant Death Syndrome, and obstetric conditions were the first through fourth most common causes of infant death under both systems, most comparability ratios were significantly different from one system to the other. Conclusion The Dollfus classification system can be adapted for use with ICD-10 codes to create a comprehensive, etiology-based profile of infant deaths. The potential benefits of using Dollfus logic to guide perinatal mortality reduction strategies, particularly to maternal and child health programs and other initiatives focused on improving infant health, warrant further examination of this method's use in perinatal mortality surveillance. PMID:26556935
Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco
2018-04-01
During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.
Kuhle, Stefan; Kirk, Sara F L; Ohinmaa, Arto; Veugelers, Paul J
2011-12-21
Administrative health databases are a valuable research tool to assess health care utilization at the population level. However, their use in obesity research limited due to the lack of data on body weight. A potential workaround is to use the ICD code of obesity to identify obese individuals. The objective of the current study was to investigate the sensitivity and specificity of an ICD code-based diagnosis of obesity from administrative health data relative to the gold standard measured BMI. Linkage of a population-based survey with anthropometric measures in elementary school children in 2003 with longitudinal administrative health data (physician visits and hospital discharges 1992-2006) from the Canadian province of Nova Scotia. Measured obesity was defined based on the CDC cut-offs applied to the measured BMI. An ICD code-based diagnosis obesity was defined as one or more ICD-9 (278) or ICD-10 code (E66-E68) of obesity from a physician visit or a hospital stay. Sensitivity and specificity were calculated and health care cost estimates based on measured obesity and ICD-based obesity were compared. The sensitivity of an ICD code-based obesity diagnosis was 7.4% using ICD codes between 2002 and 2004. Those correctly identified had a higher BMI and had higher health care utilization and costs. An ICD diagnosis of obesity in Canadian administrative health data grossly underestimates the true prevalence of childhood obesity and overestimates the health care cost differential between obese and non-obese children.
Impulse control disorders in Parkinson's disease: the role of personality and cognitive status.
Poletti, Michele; Bonuccelli, Ubaldo
2012-11-01
This study reviews empirical findings on two debated issues related to the phenomenon of impulse control disorders (ICD) in patients with Parkinson's disease (PD) treated with dopamine agonists: the role of "premorbid" or "baseline" personality traits and the role of cognitive status. A review of both these issues may help clinicians to understand why only some PD patients, when treated with dopamine agonists, develop an ICD: besides the treatment, which other neuropsychiatric characteristics represent a risk factor to develop an ICD? A literature review was performed on studies of ICD in PD patients, in electronic databases ISI Web of Knowledge, Medline and PsychInfo, conducted in January 2011. In the general population, impulsivity, depression and difficulties with executive functions, especially of inhibitory control, are factors associated with ICD development. As regards cognitive functions, PD patients present executive difficulties, and patients with ICD present more difficulties in comparison to patients without ICD. As regards personality characteristics, PD patients present a trait of negative affect, which could predispose them to affective disorders and could represent an affective risk factor for the development of ICD; as regards impulsivity, preliminary findings support the hypothesis that premorbid "baseline" levels may moderate the decrease of impulsivity because of the progressive dopaminergic deficit in PD patients and therefore also moderate the development of ICD. Longitudinal psychometric and cognitive studies, following PD patients since the clinical diagnosis and during dopaminergic treatment, are needed to confirm the role of personality traits and cognitive status on ICD development in this clinical population.
Al-Khatib, Sana M; Sanders, Gillian D; O'Brien, Sean M; Matlock, Daniel; Zimmer, Louise O; Masoudi, Frederick A; Peterson, Eric
2011-01-01
Implantable cardioverter defibrillator (ICD) therapy improves survival of patients with systolic heart failure. We assessed whether physicians' recommendation for ICD therapy varies as a function of patient age, gender, race, and physician's specialty. We surveyed a random sample (n = 9969) of U.S. physicians who are active members of the American College of Cardiology (ACC). We asked participants about their likelihood to recommend ICD therapy in 4 clinical scenarios that randomly varied patient age, gender, race, and ICD indication (guideline Class I, Class IIa, Class III, and Class I in a noncompliant patient). Responses were received from 1210 physicians (response rate 12%), of whom 1127 met the study inclusion criteria. Responders and nonresponders had similar demographics. In responding to hypothetical clinical scenarios, physicians were less likely to recommend an ICD to older patients (≥80 vs 50 years) (P < 0.01) but were unaffected by gender or race for all class indications. Compared with non-electrophysiologists (EPs), EPs were significantly more likely to recommend an ICD for a Class I indication (92.4% vs 81.4%; P < 0.01), but they were not more likely to offer an ICD for a Class III indication (0.4% vs 0.6%; P = 0.95). Based on survey responses, physicians were equally willing to offer an ICD to men and women and to whites and blacks, but were less likely to offer an ICD to an older patient even when indicated by practice guidelines. Electrophysiologists (EPs) more often adhered to practice guideline recommendations on ICD therapy compared with non-EPs. ©2011, Wiley Periodicals, Inc.
Rahmawati, Anita; Chishaki, Akiko; Sawatari, Hiroyuki; Tsuchihashi-Makaya, Miyuki; Ohtsuka, Yuko; Nakai, Mori; Miyazono, Mami; Hashiguchi, Nobuko; Sakurada, Harumizu; Takemoto, Masao; Mukai, Yasushi; Inoue, Shujiro; Sunagawa, Kenji; Chishaki, Hiroaki
2013-01-01
Implantable cardioverter-defibrillator (ICD) has improved prognosis in fatal arrhythmia and the number of ICD implantations has increased. ICD-related psychological problems and impaired quality of life (QOL), however, have been observed. This study examined whether gender differences exist in QOL and psychological disturbances in ICD patients. Consecutive outpatients (n=179; mean age, 60.5±15.9 years; 81% male) with ICD implantations completed questionnaires consisting of the Short Form-8 (SF-8), Beck Depression Inventory, Impact of Event Scale-Revised (IES-R), State-Trait Anxiety Inventory, and Worries about ICD. One-way multivariate analysis of variance (MANOVA) showed women to have impaired QOL on the role physical functioning (F15,157=4.57, P<0.05) and bodily pain (F15,157=5.26, P<0.05) subscales of the SF-8. More women reported depression (F15,157=5.37, P<0.05) and worry about ICD than men (F15,157=6.62, P<0.05). Moreover, women also had higher IES-R scores indicating post-traumatic stress disorder (PTSD) than men (F15,157=5.87, P<0.05). Women reported poorer QOL on 2 subscales: role physical functioning and bodily pain. There was a significant relationship between gender and depression, worry about ICD, and PTSD, but not for anxiety. Female patients need more psychological interventions following ICD implantation.
Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M
2009-11-24
Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.
Bach, B; Sellbom, M; Kongerslev, M; Simonsen, E; Krueger, R F; Mulder, R
2017-07-01
The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. We examined (i) whether designated DSM-5 trait facets can be used to describe the proposed ICD-11 trait domains, and (ii) how these ICD-11 trait features are hierarchically organized. A mixed Danish derivation sample (N = 1541) of 615 psychiatric out-patients and 925 community participants along with a US replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized in the proposed ICD-11 five-domain structure as well as other recognizable higher-order models of personality and psychopathology. Model fits revealed that the five proposed ICD-11 personality disorder domains were satisfactorily resembled, and replicated in the independent US sample. The proposed ICD-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Tandon, B N; Gandhi, N
1992-01-01
The Integrated Child Development Services (ICDS) programme was launched by the Indian government in October 1975 to provide a package of health, nutrition and informal educational services to mothers and children. In 1988 we studied the impact of ICDS on the immunization coverage of children aged 12-24 months and of mothers of infants in 19 rural, 8 tribal, and 9 urban ICDS projects that had been operational for more than 5 years. Complete coverage with BCG, diphtheria-pertussis-tetanus (DPT) and poliomyelitis vaccines was recorded for 65%, 63%, and 64% of children, respectively, in the ICDS population. By comparison, the coverage in the non-ICDS group was only 22% for BCG, 28% for DPT, and 27% for poliomyelitis. Complete immunization with tetanus toxoid was recorded for 68% of the mothers in the ICDS group and for 40% in the non-ICDS group. Coverage was greater in the urban and lower in the tribal projects. Scheduled castes, scheduled tribes, backward communities, and minorities (groups that have a high priority for social services) had immunization coverages in ICDS projects that were similar to those of higher castes.
Alzand, Bsn; Phlips, Tje; Willems, R
2014-05-01
A 50-year-old male with a CRT defibrillator received inappropriate ICD shocks due to T-wave oversensing. Decreasing the sensitivity to avoid T wave oversensing was not an option due to a suboptimal R-wave sensing amplitude. We decided to re-plug the LV lead in the RV port and the RV lead in the LV port. This however led to intermittent phrenic nerve stimulation due to mandatory bipolar (tip-ring) or unipolar (tip-can) pacing on the LV-lead from the RV port. Re-intervention was necessary with the implantation of an additional pacing/sensing RV lead. A software programmable choice to switch sensing and tachycardia detection from RV to LV lead could be a valuable feature in future CRT devices.
Loeffler endocarditis: silent right ventricular myocardium!
Çetin, Süha; Heper, Gülümser; Gökhan Vural, Mustafa; Hazirolan, Tuncay
2016-07-01
We present the case of a 54-year-old male patient with Loeffler endocarditis. It is a rare disorder characterized by fibrous thickening of the endocardium leading to apical obliteration and restrictive cardiomyopathy resulting in heart failure, thromboembolic events or atrial fibrillation. To the best of our knowledge, this is the first case reporting the electrical silence of the right ventricular (RV) apex caused by fibrothrombotic thickening of this area. Under these circumstances RV apical implantation of an implantable cardioverter defibrillator (ICD) or pacemaker electrode may lead to unsuccessful stimulation of these devices.
Rosenleitner, Jan; Rittmannsberger, Hans
2013-01-01
Religious beliefs can lead to difficulties in psychiatric diagnosis, when it comes to distinguishing between faith and delusion. Delusion is defined as a false assessment of reality combined with subjective certainty, which is in contrast with the reality of the social environment. The problem with this definition is that reality cannot be examined with scientific methods/criteria and that the assessment of reality itself underlies historical and cultural fluctuations. The current diagnostic manuals for psychiatric disorders DSM 5 and ICD-10 require, that the content of the belief has to be inadequate even in the subculture of the patient (ICD-10) and that the cultural and socioeconomic background of the patient has to be taken into account (DSM 5). On the basis of this case-report and of selected publications on this topic we want to discuss this diagnostic problem. After that we present a diagnostic model for delusion, which is easy to handle in the daily routine of psychiatrists.
Molecular imaging and neural networks in impulse control disorders in Parkinson's disease.
Aracil-Bolaños, I; Strafella, A P
2016-01-01
Impulse control disorders (ICDs) may arise in Parkinson's disease (PD) in relation to the use of dopamine agonists (DA). A dysfunction of reward circuits is considered the main underlying mechanism. Neuroimaging has been largely used in this setting to understand the structure of the reward system and its abnormalities brought by exogenous stimulation in PD. Dopaminergic changes, such as increased dopamine release, reduced dopamine transporter activity and other changes, have been shown to be a consistent feature of ICDs in PD. Beyond the striatum, alterations of prefrontal cortical function may also impact an individuals' propensity for impulsivity. Neuroimaging is advancing our knowledge of the mechanisms involved in the development of these behavioral addictions. An increased understanding of these disorders may lead to the discovery of new therapeutic targets, or the identification of risk factors for the development of these disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.
The subcutaneous implantable cardioverter-defibrillator.
Grace, Andrew
2014-01-01
To consider the case of need that underpinned the development of the subcutaneous implantable cardioverter-defibrillator (SICD), the preclinical and clinical data obtained so far, its current role and likely future. The data from prospective clinical evaluation of the device demonstrated safety and efficacy leading to Food and Drug Administration approval. This superseded earlier reports from Europe that raised some clinical concerns, previously anticipated through the introduction of new technology. Recent estimates indicate maybe 55% of patients in routine clinical practice needing an ICD are potentially suitable for a subcutaneous device. The SICD provides a useful alternative for high-energy (ICD) therapy in those deemed at risk and who need defibrillation and in whom there are no indications for cardiac resynchronization, bradycardia support or antitachycardia pacing. There is the possibility of both higher specificity and the avoidance of myo-cellular damage with shock delivery, and if these two aspects play out subcutaneous defibrillation could become an option of choice in many settings.
Jordan, Jochen; Titscher, Georg; Peregrinova, Ludmila; Kirsch, Holger
2013-01-01
Background: In view of the increasing number of implanted cardioverter defibrillators (ICD), the number of people suffering from so-called “multiple ICD shocks” is also increasing. The delivery of more than five shocks (appropriate or inappropriate) in 12 months or three or more shocks (so called multiple shocks) in a short time period (24 hours) leads to an increasing number of patients suffering from severe psychological distress (anxiety disorder, panic disorder, adjustment disorder, post-traumatic stress disorder). Untreated persons show chronic disease processes and a low rate of spontaneous remission and have an increased morbidity and mortality. Few papers have been published concerning the psychotherapeutic treatment for these patients. Objective: The aim of this study is to develop a psychotherapeutic treatment for patients with a post-traumatic stress disorder or adjustment disorder after multiple ICD shocks. Design: Explorative feasibility study: Treatment of 22 patients as a natural design without randomisation and without control group. The period of recruitment was three years, from March 2007 to March 2010. The study consisted of two phases: in the first phase (pilot study) we tested different components and dosages of psychotherapeutic treatments. The final intervention programme is presented in this paper. In the second phase (follow-up study) we assessed the residual post-traumatic stress symptoms in these ICD patients. The time between treatment and follow-up measurement was 12 to 30 months. Population: Thirty-one patients were assigned to the Department of Psychocardiology after multiple shocks. The sample consisted of 22 patients who had a post-traumatic stress disorder or an adjustment disorder and were willing and able to participate. They were invited for psychological treatment. 18 of them could be included into the follow-up study. Methods: After the clinical assessment at the beginning and at the end of the inpatient treatment a post-treatment assessment with questionnaires followed. In this follow-up measurement, minimum 12 months after inpatient treatment, posttraumatic stress was assessed using the “Impact of Event Scale” (IES-R). Setting: Inpatient treatment in a large Heart and Thorax Centre with a Department of Psychocardiology (Kerckhoff Heart Centre). Results: From the 18 patients in the follow-up study no one reported complaints of PTSD. 15 of them reported a high or even a very high decrease of anxiety and avoidance behaviour. Conclusions: The fist step of the treatment development seems to be successful. It shows encouraging results with an acceptable dosage. The second step of our work is in process now: we evaluate the treatment manual within other clinical institutions and a higher number of psychotherapists. This leads in the consequence to a controlled and randomised comparison study. PMID:24403967
Al-Khatib, Sana M.; Hellkamp, Anne; Bardy, Gust H.; Hammill, Stephen; Jackson Hall, W.; Mark, Daniel B.; Anstrom, Kevin J.; Curtis, Jeptha; Al-Khalidi, Hussein; Curtis, Lesley H.; Heidenreich, Paul; Peterson, Eric D.; Sanders, Gillian; Clapp-Channing, Nancy; Lee, Kerry L.; Moss, Arthur J.
2013-01-01
Importance Randomized clinical trials have shown that implantable cardioverter-defibrillator (ICD) therapy saves lives. Whether the survival of patients who received an ICD in primary prevention clinical trials differs from that of trial-eligible patients receiving a primary prevention ICD in clinical practice is unknown. Objective To determine whether trial-eligible patients who received a primary prevention ICD as documented in a large national registry have a survival rate that differs from the survival rate of similar patients who received an ICD in the 2 largest primary prevention clinical trials, MADIT-II (n=742) and SCD-HeFT (n=829). Design, Setting, and Patients Retrospective analysis of data for patients enrolled in the National Cardiovascular Data Registry ICD Registry between January 1, 2006, and December 31, 2007, meeting the MADIT-II criteria (2464 propensity score–matched patients) or the SCD-HeFT criteria (3352 propensity score–matched patients). Mortality data for the registry patients were collected through December 31, 2009. Main Outcome Measures Cox proportional hazards models were used to compare mortality from any cause. Results The median follow-up time in MADIT-II, SCD-HeFT, and the ICD Registry was 19.5, 46.1, and 35.2 months, respectively. Compared with patients enrolled in the clinical trials, patients in the ICD Registry were significantly older and had a higher burden of comorbidities. In the matched cohorts, there was no significant difference in survival between MADIT-II–like patients in the registry and MADIT-II patients randomized to receive an ICD (2-year mortality rates: 13.9% and 15.6%, respectively; adjusted ICD Registry vs trial hazard ratio, 1.06; 95% CI, 0.85–1.31; P=.62). Likewise, the survival among SCD-HeFT–like patients in the registry was not significantly different from survival among patients randomized to receive ICD therapy in SCD-HeFT (3-year mortality rates: 17.3% and 17.4%, respectively; adjusted registry vs trial hazard ratio, 1.16; 95% CI, 0.97–1.38; P=.11). Conclusions and Relevance There was no significant difference in survival between clinical trial patients randomized to receive an ICD and a similar group of clinical registry patients who received a primary prevention ICD. Our findings support the continued use of primary prevention ICDs in similar patients seen in clinical practice. Trial Registration clinicaltrials.gov Identifier: NCT00000609 PMID:23280225
Go, Michael R; Masterson, Loren; Veerman, Brent; Satiani, Bhagwan
2016-02-01
To curb increasing volumes of diagnostic imaging and costs, reimbursement for carotid duplex ultrasound (CDU) is dependent on "appropriate" indications as documented by International Classification of Diseases (ICD) codes entered by ordering physicians. Historically, asymptomatic indications for CDU yield lower rates of abnormal results than symptomatic indications, and consensus documents agree that most asymptomatic indications for CDU are inappropriate. In our vascular laboratory, we perceived an increased rate of incorrect or inappropriate ICD codes. We therefore sought to determine if ICD codes were useful in predicting the frequency of abnormal CDU. We hypothesized that asymptomatic or nonspecific ICD codes would yield a lower rate of abnormal CDU than symptomatic codes, validating efforts to limit reimbursement in asymptomatic, low-yield groups. We reviewed all outpatient CDU done in 2011 at our institution. ICD codes were recorded, and each medical record was then reviewed by a vascular surgeon to determine if the assigned ICD code appropriately reflected the clinical scenario. CDU findings categorized as abnormal (>50% stenosis) or normal (<50% stenosis) were recorded. Each individual ICD code and group 1 (asymptomatic), group 2 (nonhemispheric symptoms), group 3 (hemispheric symptoms), group 4 (preoperative cardiovascular examination), and group 5 (nonspecific) ICD codes were analyzed for correlation with CDU results. Nine hundred ninety-four patients had 74 primary ICD codes listed as indications for CDU. Of assigned ICD codes, 17.4% were deemed inaccurate. Overall, 14.8% of CDU were abnormal. Of the 13 highest frequency ICD codes, only 433.10, an asymptomatic code, was associated with abnormal CDU. Four symptomatic codes were associated with normal CDU; none of the other high frequency codes were associated with CDU result. Patients in group 1 (asymptomatic) were significantly more likely to have an abnormal CDU compared to each of the other groups (P < 0.001, P < 0.001, P = 0.020, P = 0.002) and to all other groups combined (P < 0.001). Asymptomatic indications by ICD codes yielded higher rates of abnormal CDU than symptomatic indications. This finding is inconsistent with clinical experience and historical data, and we suggest that inaccurate coding may play a role. Limiting reimbursement for CDU in low-yield groups is reasonable. However, reimbursement policies based on ICD coding, for example, limiting payment for asymptomatic ICD codes, may impede use of CDU in high-yield patient groups. Copyright © 2016 Elsevier Inc. All rights reserved.
Lupo, Pierpaolo; Cappato, Riccardo; Di Leo, Giovanni; Secchi, Francesco; Papini, Giacomo D E; Foresti, Sara; Ali, Hussam; De Ambroggi, Guido M G; Sorgente, Antonio; Epicoco, Gianluca; Cannaò, Paola M; Sardanelli, Francesco
2018-06-01
To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.
Sharma, Ashish; Goyal, Vinay; Behari, Madhuri; Srivastva, Achal; Shukla, Garima; Vibha, Deepti
2015-01-01
Background: There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs) in Indian patients with Parkinson's Disease (PD). In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. Objectives: To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated “Questionnaire for Impulsive-Compulsive Disorders in Parkinson's disease (QUIP)” and to examine their association with Dopamine replacement therapy (DRT). Materials and Methods: This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver) were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Results: Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%), at least one Impulse control disorder (ICD) was present in 74 (24.75%) and at least one Impulse control related compulsive behaviour (ICRB) was present in 93 (31.1%) patients. Punding was the most frequent (12.4%) followed by hyper sexuality (11.04%), compulsive hobbyism (9.4%), compulsive shopping (8.4%), compulsive medication use (7.7%), compulsive eating (5.35%), walkabout (4%) and pathological gambling (3.3%). ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD) were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Conclusions: Our study revealed a relatively higher frequency of ICD-RBs, probably because of the use of screening instrument and because we combined both ICDs and ICRBs. Also high proportion of DA use (81.6%) among our patients might be responsible. The role of genetic factors that might increase the risk of developing ICD-RBs in this population needs further exploration. PMID:25745311
Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J
1998-11-01
A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.
42 CFR Appendix A to Part 81 - Glossary of ICD-9 Codes and Their Cancer Descriptions 1
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Glossary of ICD-9 Codes and Their Cancer.... 81, App. A Appendix A to Part 81—Glossary of ICD-9 Codes and Their Cancer Descriptions 1 ICD-9 code Cancer description 140 Malignant neoplasm of lip. 141 Malignant neoplasm of tongue. 142 Malignant...
ERIC Educational Resources Information Center
Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten
2009-01-01
Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…
Effectiveness of implantable cardioverter-defibrillators in survivors of inhospital cardiac arrest.
Chan, Paul S; Krumholz, Harlan M; Spertus, John A; Curtis, Lesley H; Li, Yan; Hammill, Bradley G; Nallamothu, Brahmajee K
2015-06-01
Although implantable cardioverter-defibrillators (ICDs) reduce mortality in patients with out-of-hospital cardiac arrest, their effectiveness in survivors of "inhospital" cardiac arrest-a population with different arrest etiologies and higher illness acuity than out-of-hospital cardiac arrest-is unknown. We therefore sought to conduct a comparative effectiveness study of ICD therapy in survivors of inhospital cardiac arrest. We linked data from a national inpatient cardiac arrest registry with Medicare files and identified 1,200 adults from 267 hospitals between 2000 and 2008 who were discharged after surviving an inhospital cardiac arrest due to ventricular fibrillation or pulseless ventricular tachycardia and who otherwise met traditional inclusion and exclusion criteria for secondary prevention ICD trials. The association between ICD treatment and long-term mortality was evaluated using an optimal match (≤4 controls for each ICD patient) propensity-score analysis. Of 1,200 survivors, 343 (28.6%) received an ICD during the index hospitalization. Overall, 3-year mortality was 44.2%, with higher unadjusted mortality in the non-ICD versus the ICD group (46.9% vs 37.3%; log-rank; P < .001). After successfully matching 343 patients treated with ICDs with 823 untreated patients by propensity score, ICD treatment was associated with a 24% lower mortality rate (adjusted hazard ratio [HR] 0.76; 95% CI 0.60-0.97; P = .025). This lower mortality was mediated by lower rates of out-of-hospital deaths among ICD-treated patients (22.1% vs 30.8%; adjusted HR 0.71 [0.52-0.96]; P = .019), whereas deaths occurring during a readmission were similar (15.2% vs 16.1%; adjusted HR 0.89 [95% CI 0.60-1.32]; P = .56). Implantable cardioverter-defibrillator therapy in survivors of inhospital cardiac arrest due to a pulseless ventricular rhythm is used uncommonly but associated with lower long-term mortality. Given that fewer than 3 in 10 eligible survivors are treated with ICDs after surviving an inhospital cardiac arrest, our findings highlight a potentially modifiable process of care, which could improve long-term survival in this high-risk population. Copyright © 2015 Elsevier Inc. All rights reserved.
van der Heijden, Aafke C.; van Rees, Johannes B.; Levy, Wayne C.; van der Bom, Johanna G.; Cannegieter, Suzanne C.; de Bie, Mihàly K.; van Erven, Lieselot; Schalij, Martin J.; Borleffs, C. Jan Willem
2017-01-01
Aims Implantable cardioverter-defibrillator (ICD) treatment is beneficial in selected patients. However, it remains difficult to accurately predict which patients benefit most from ICD implantation. For this purpose, different risk models have been developed. The aim was to validate and compare the FADES, MADIT, and SHFM-D models. Methods and results All patients receiving a prophylactic ICD at the Leiden University Medical Center were evaluated. Individual model performance was evaluated by C-statistics. Model performances were compared using net reclassification improvement (NRI) and integrated differentiation improvement (IDI). The primary endpoint was non-benefit of ICD treatment, defined as mortality without prior ventricular arrhythmias requiring ICD intervention. A total of 1969 patients were included (age 63 ± 11 years; 79% male). During a median follow-up of 4.5 ± 3.9 years, 318 (16%) patients died without prior ICD intervention. All three risk models were predictive for event-free mortality (all: P < 0.001). The C-statistics were 0.66, 0.69, and 0.75, respectively, for FADES, MADIT, and SHFM-D (all: P < 0.001). Application of the SHFM-D resulted in an improved IDI of 4% and NRI of 26% compared with MADIT; IDI improved 11% with the use of SHFM-D instead of FADES (all: P < 0.001), but NRI remained unchanged (P = 0.71). Patients in the highest-risk category of the MADIT and SHFM-D models had 1.7 times higher risk to experience ICD non-benefit than receive appropriate ICD interventions [MADIT: mean difference (MD) 20% (95% CI: 7–33%), P = 0.001; SHFM-D: MD 16% (95% CI: 5–27%), P = 0.005]. Patients in the highest-risk category of FADES were as likely to experience ICD intervention as ICD non-benefit [MD 3% (95% CI: –8 to 14%), P = 0.60]. Conclusion The predictive and discriminatory value of SHFM-D to predict non-benefit of ICD treatment is superior to FADES and MADIT in patients receiving prophylactic ICD treatment. PMID:28130376
Killingsworth, Cheryl R; Melnick, Sharon B; Litovsky, Silvio H; Ideker, Raymond E; Walcott, Gregory P
2013-10-01
A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. During sinus rhythm, anesthetized pigs (38 ± 6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24 hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semiquantitative scoring. Troponin I was significantly elevated at 4 hours and 24 hours (22.6 ± 16.3 ng/mL and 3.1 ± 1.3 ng/mL; baseline 0.07 ± 0.09 ng/mL) in control pigs but not in S-ICD pigs (0.12 ± 0.11 ng/mL and 0.13 ± 0.13 ng/mL; baseline 0.06 ± 0.03 ng/mL). CK-MM was significantly elevated in S-ICD pigs after shocks (6,544 ± 1,496 U/L and 9,705 ± 6,240 U/L; baseline 704 ± 398 U/L) but not in controls. Electrocardiogram changes occurred postshock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.
Imidacloprid sorption and transport in cropland, grass buffer and riparian buffer soils
Satkowski, Laura E.; Goyne, Keith W.; Anderson, Stephen H.; Lerch, Robert N.; Allen, Craig R.; Snow, Daniel D.
2018-01-01
An understanding of neonicotinoid sorption and transport in soil is critical for determining and mitigating environmental risk associated with the most widely used class of insecticides. The objective of this study was to evaluate mobility and transport of the neonicotinoid imidacloprid (ICD) in soils collected from cropland, grass vegetative buffer strip (VBS), and riparian VBS soils. Soils were collected at six randomly chosen sites within grids that encompassed all three land uses. Single-point equilibrium batch sorption experiments were conducted using radio-labeled (14C) ICD to determine solid–solution partition coefficients (Kd). Column experiments were conducted using soils collected from the three vegetation treatments at one site by packing soil into glass columns. Water flow was characterized by applying Br− as a nonreactive tracer. A single pulse of 14C-ICD was then applied, and ICD leaching was monitored for up to 45 d. Bromide and ICD breakthrough curves for each column were simulated using CXTFIT and HYDRUS-1D models. Sorption results indicated that ICD sorbs more strongly to riparian VBS (Kd = 22.6 L kg−1) than crop (Kd = 11.3 L kg−1) soils. Soil organic C was the strongest predictor of ICD sorption (p < 0.0001). The column transport study found mean peak concentrations of ICD at 5.83, 10.84, and 23.8 pore volumes for crop, grass VBS, and riparian VBS soils, respectively. HYDRUS-1D results indicated that the two-site, one-rate linear reversible model best described results of the breakthrough curves, indicating the complexity of ICD sorption and demonstrating its mobility in soil. Greater sorption and longer retention by the grass and riparian VBS soils than the cropland soil suggests that VBS may be a viable means to mitigate ICD loss from agroecosystems, thereby preventing ICD transport into surface water, groundwater, or drinking water resources.
Boyd, Andrew D; Li, Jianrong John; Kenost, Colleen; Joese, Binoy; Yang, Young Min; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A
2015-05-01
In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as "convoluted" by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: "identity" (reciprocal), "class-to-subclass," "subclass-to-class," "convoluted," or "no mapping." These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible.Web portal: http://www.lussierlab.org/transition-to-ICD9CM/Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.
Clinical-genetic model predicts incident impulse control disorders in Parkinson's disease.
Kraemmer, Julia; Smith, Kara; Weintraub, Daniel; Guillemot, Vincent; Nalls, Mike A; Cormier-Dequaire, Florence; Moszer, Ivan; Brice, Alexis; Singleton, Andrew B; Corvol, Jean-Christophe
2016-10-01
Impulse control disorders (ICD) are commonly associated with dopamine replacement therapy (DRT) in patients with Parkinson's disease (PD). Our aims were to estimate ICD heritability and to predict ICD by a candidate genetic multivariable panel in patients with PD. Data from de novo patients with PD, drug-naïve and free of ICD behaviour at baseline, were obtained from the Parkinson's Progression Markers Initiative cohort. Incident ICD behaviour was defined as positive score on the Questionnaire for Impulsive-Compulsive Disorders in PD. ICD heritability was estimated by restricted maximum likelihood analysis on whole exome sequencing data. 13 candidate variants were selected from the DRD2, DRD3, DAT1, COMT, DDC, GRIN2B, ADRA2C, SERT, TPH2, HTR2A, OPRK1 and OPRM1 genes. ICD prediction was evaluated by the area under the curve (AUC) of receiver operating characteristic (ROC) curves. Among 276 patients with PD included in the analysis, 86% started DRT, 40% were on dopamine agonists (DA), 19% reported incident ICD behaviour during follow-up. We found heritability of this symptom to be 57%. Adding genotypes from the 13 candidate variants significantly increased ICD predictability (AUC=76%, 95% CI (70% to 83%)) compared to prediction based on clinical variables only (AUC=65%, 95% CI (58% to 73%), p=0.002). The clinical-genetic prediction model reached highest accuracy in patients initiating DA therapy (AUC=87%, 95% CI (80% to 93%)). OPRK1, HTR2A and DDC genotypes were the strongest genetic predictive factors. Our results show that adding a candidate genetic panel increases ICD predictability, suggesting potential for developing clinical-genetic models to identify patients with PD at increased risk of ICD development and guide DRT management. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A scoping review of ICD-11 adjustment disorder research.
Kazlauskas, Evaldas; Zelviene, Paulina; Lorenz, Louisa; Quero, Soledad; Maercker, Andreas
2017-01-01
Background : Adjustment disorder (AjD) is one of the most used mental disorder diagnoses among mental health professionals. Important revisions of the AjD definition in the 11th edition of the International Classification of Diseases (ICD-11) are proposed. AjD is included in a chapter of disorders specifically associated with stress in ICD-11. Objective : This paper aims to review recent developments in ICD-11 AjD research, and to discuss the available ICD-11 AjD diagnosis validation studies, AjD measures, treatment studies, and outline the future perspectives for AjD research and clinical practice. Methods : In total, 10 empirical studies of AjD ICD-11 were identified and included in this review. We searched for studies in Embase, PubMed, PsycINFO, Scopus, PILOTS, SocINDEX, and via additional search by contacting authors of published empirical studies and reference screening. Results : Review of the studies revealed a lack of validation studies of the ICD-11 AjD symptom structure. AjD validation study findings are ambiguous, and there is still little support for the proposed two symptom structure of AjD for the ICD-11. A self-report AjD measure 'Adjustment Disorder New Module' (ADNM) based on the ICD-11 definition has been developed and used in all 10 reviewed studies. Two self-help interventions have been developed for the ICD-11 AjD, and findings from these studies indicate that self-help low-intensity cognitive-behavioural interventions, delivered via bibliography or internet-based, might be effective treatment of AjD. Conclusions : The AjD definition in ICD-11 with a description of a new symptom profile facilitates AjD measurement and AjD-focused treatment developments. More studies and insights from clinical practice are needed to move the field of AjD research and practice forward.
Cost-effectiveness of the implantable cardioverter defibrillator: a review of current evidence.
Lynd, Larry D; O'Brien, Bernie J
2003-09-01
Implantable cardioverter defibrillator (ICD) therapy is indicated for patients at risk for sudden cardiac death (SCD) due to ventricular tachycardia (VT) or ventricular fibrillation (VF). The high relative cost of therapy with the ICD versus antiarrhythmic drugs has raised questions regarding its cost-effectiveness. To address these questions, we review the literature on ICD cost-effectiveness. MEDLINE and other databases were searched for articles published since 1980 reporting original data on the cost-effectiveness of ICD versus drug therapy for patients at risk for SCD. Data on costs and life-years were abstracted and studies grouped into decision analysis models and trial-based analyses. Cost-effectiveness ratios were inflated to 2002 US dollars. Thirteen economic studies were included in this review: 6 decision-analytic models, 4 economic analysis alongside randomized controlled trials, and 1 observational study. Two additional studies evaluated the cost-effectiveness of ICDs stratified by mortality risk. Studies varied in time horizon, and in all but one study ICD therapy was more costly than drug therapy. Early models assumed larger survival benefits than were observed in subsequent trials; therefore, ICDs appeared to be more cost-effective (i.e., US dollars 28000-US dollars 60000 per life-year gained). Three large clinical trial-based studies estimated that the cost per life-year gained was between US dollars 30181 and US dollars 185000. Stratified analyses show that patients at higher risk for mortality due to structural heart disease (e.g., left ventricular ejection fraction <35%) benefit more from ICD therapy, resulting in lower cost-effectiveness ratios. ICD therapy continues to evolve with changing methods of implantation and improving technology. Current evidence suggests that ICDs may be a cost-effective option in patients at high risk for VT/VF. The cost-effectiveness of ICD therapy for primary and secondary prevention of SCD depends upon patient characteristics that influence their prior risk of mortality. Further research on patient selection criteria and the measurement of health-related quality of life is required.
Nilsson, Johan; Östling, Svante; Waern, Margda; Karlsson, Björn; Sigström, Robert; Guo, Xinxin; Skoog, Ingmar
2012-11-01
To examine the 1-month prevalence of generalized anxiety disorder (GAD) according to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), Diagnostic and Statistical Manual of Mental, Fifth Edition (DSM-V), and International Classification of Diseases, Tenth Revision (ICD-10), and the overlap between these criteria, in a population sample of 75-year-olds. We also aimed to examine comorbidity between GAD and other psychiatric diagnoses, such as depression. During 2005-2006, a comprehensive semistructured psychiatric interview was conducted by trained nurses in a representative population sample of 75-year-olds without dementia in Gothenburg, Sweden (N = 777; 299 men and 478 women). All psychiatric diagnoses were made according to DSM-IV. GAD was also diagnosed according to ICD-10 and DSM-V. The 1-month prevalence of GAD was 4.1% (N = 32) according to DSM-IV, 4.5% (N = 35) according to DSM-V, and 3.7% (N = 29) according to ICD-10. Only 46.9% of those with DSM-IV GAD fulfilled ICD-10 criteria, and only 51.7% and 44.8% of those with ICD-10 GAD fulfilled DSM-IV/V criteria. Instead, 84.4% and 74.3% of those with DSM-IV/V GAD and 89.7% of those with ICD-10 GAD had depression. Also other psychiatric diagnoses were common in those with ICD-10 and DSM-IV GAD. Only a small minority with GAD, irrespective of criteria, had no other comorbid psychiatric disorder. ICD-10 GAD was related to an increased mortality rate. While GAD was common in 75-year-olds, DSM-IV/V and ICD-10 captured different individuals. Current definitions of GAD may comprise two different expressions of the disease. There was greater congruence between GAD in either classification system and depression than between DSM-IV/V GAD and ICD-10 GAD, emphasizing the close link between these entities. 2012 American Association for Geriatric Psychiatry
Voskoboinik, Aleksandr; Bloom, Jason; Taylor, Andrew; Mariani, Justin
2016-09-01
Primary prevention implantable cardioverter defibrillators (ICDs) reduce mortality in selected patients with severe systolic dysfunction. Current guidelines suggest a 3- to 6-month waiting period before implantation. We retrospectively studied 29 consecutive patients with newly diagnosed nonischemic cardiomyopathy (NICM) who underwent primary prevention ICD implantation within 6 months of diagnosis between January 2008 and April 2014. Cardiac MRI (CMR) evaluated left ventricular ejection fraction (LVEF) and regional fibrosis preimplant. The primary end point was "failure to qualify for an ICD at 12 months postimplant," either due to LVEF ≥ 35% or deterioration necessitating mechanical support or transplantation, without appropriate ICD therapy. Secondary end points were appropriate and inappropriate ICD therapy. Baseline mean age was 44.2 ± 14.8 years and median LVEF 16.4%. Median time from diagnosis to implant was 32 days. At 12 months, 17 patients (58.6%) no longer qualified for an ICD, mainly due to LVEF improvement. At follow-up (mean 32.0 ± 20.6 months), three patients received appropriate therapy (one for ventricular fibrillation). All three had CMR late gadolinium enhancement (LGE) and nonsustained ventricular tachycardia (NSVT) preimplant. Cardiac resynchronization at implant predicted LVEF improvement. Early appropriate therapy, particularly for ventricular fibrillation, is infrequent for patients with very severe NICM who have ICDs implanted within 6 months of diagnosis. The majority of these patients would not qualify for an ICD at 12 months postinsertion. In the absence of a multimodality risk score, early ICD insertion should only be considered in selected cases (presence of LGE and NSVT). Wearable cardioverter defibrillators may have a role as a bridge to ICD decision. © 2016 Wiley Periodicals, Inc.
Stavrakis, Stavros; Asad, Zain; Reynolds, Dwight
2017-06-01
Implantable cardioverter defibrillators (ICDs) improve survival in patients with heart failure due to ischemic cardiomyopathy, but their benefit in nonischemic cardiomyopathy (NICM) has been recently questioned. We performed a meta-analysis of randomized clinical trials to examine the effect of ICDs on total mortality and arrhythmic death in patients with NICM. We also examined the impact of age and cardiac resynchronization therapy (CRT) on the relative effect of ICD compared to control. We searched the MEDLINE and EMBASE databases for randomized trials evaluating the effect of ICD versus control in patients with NICM. Hazard ratios (HR) with 95% confidence interval (CI) were calculated using a random effects model. Six trials involving 2,967 patients were included (ICD, n = 1,553; control, n = 1,414). Based on the pooled estimate across the six studies, the use of ICD was associated with a significant reduction in total mortality (HR = 0.78, 95% CI 0.66-0.92; P = 0.003), as well as arrhythmic death (HR = 0.46, 95% CI 0.29-0.71; P = 0.0005) compared to control. ICD decreased total mortality in younger patients compared to control (HR = 0.63, 95% CI 0.46-0.86; P = 0.004), but not in older patients (HR = 0.97, 95% CI 0.56-1.68; P = 0.92). In patients with CRT, ICD reduced total mortality compared to control (HR = 0.78, 95% CI 0.65-0.95; P = 0.02), but not in patients with CRT (HR = 0.71, 95% CI 0.40-1.26). ICDs decrease total mortality and arrhythmic deaths in patients with NICM. The benefit of ICD appears to be dependent on age and concomitant use of CRT. © 2017 Wiley Periodicals, Inc.
Noyes, Katia; Corona, Ethan; Veazie, Peter; Dick, Andrew W.; Zhao, Hongwei; Moss, Arthur J.
2015-01-01
Background While implantable cardioverter-defibrillators (ICDs) improve survival, their benefit in terms of health-related quality of life (HRQOL) is negligible. Objective To examine how shocks and congestive heart failure (CHF) mediate the effect of ICDs on HRQOL. Methods The US patients from the MADIT-II (Multicenter Automatic Defibrillator Trial-II) trial (n = 983) were randomized to receive an ICD or medical treatment only. HRQOL was assessed using the Health Utility Index 3 at baseline and 3, 12, 24, and 36 months following randomization. Logistic regressions were used to test for the effect of ICDs on the CHF indicator, and linear regressions were used to examine the effect of ICD shocks and CHF on HRQOL in living patients. We used a Monte Carlo simulation and a parametric Weibull distribution survival model to test for the effect of selective attrition. Observations were clustered by patients and robust standard errors (RSEs) were used to control for the non-independence of multiple observations provided by the same patient. Results Patients in the ICD arm had 41% higher odds of experiencing CHF since their last assessment compared with those in the control arm (RSE = 0.19, p = 0.01). Developing CHF reduced HRQOL at the subsequent visit by 0.07 (p < 0.01). Having ICD shocks reduced overall HRQOL by 0.04 (p = 0.04) at the subsequent assessment. The negative effect of ICD firing on HRQOL was an order of magnitude greater than the effect of CHF. Conclusions A higher prevalence of CHF and shocks among patients with ICDs and their negative effect on HRQOL may partially explain the lack of HRQOL benefit of ICD therapy. PMID:19929037
Diagnostic Concordance between DSM-5 and ICD-10 Cannabis Use Disorders.
Proctor, Steven L; Williams, Daniel C; Kopak, Albert M; Voluse, Andrew C; Connolly, Kevin M; Hoffmann, Norman G
2016-07-01
With the recent federal mandate that all U.S. health care settings transition to ICD-10 billing codes, empirical evidence is necessary to determine if the DSM-5 designations map to their respective ICD-10 diagnostic categories/billing codes. The present study examined the concordance between DSM-5 and ICD-10 cannabis use disorder diagnoses. Data were derived from routine clinical assessments of 6871 male and 801 female inmates recently admitted to a state prison system from 2000 to 2003. DSM-5 and ICD-10 diagnostic determinations were made from algorithms corresponding to the respective diagnostic formulations. Past 12-month prevalence rates of cannabis use disorders were comparable across classification systems. The vast majority of inmates with no DSM-5 diagnosis continued to have no diagnosis per the ICD-10, and a similar proportion with a DSM-5 severe diagnosis received an ICD-10 dependence diagnosis. Most of the variation in diagnostic classifications was accounted for by those with a DSM-5 moderate diagnosis in that approximately half of these cases received an ICD-10 dependence diagnosis while the remaining cases received a harmful use diagnosis. Although there appears to be a generally high level of agreement between diagnostic classification systems for those with no diagnosis or those evincing symptoms of a more severe condition, concordance between DSM-5 moderate and ICD-10 dependence diagnoses was poor. Additional research is warranted to determine the appropriateness and implications of the current DSM-5 coding guidelines regarding the assignment of an ICD-10 dependence code for those with a DSM-5 moderate diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hyland, Philip; Shevlin, Mark; Fyvie, Claire; Karatzias, Thanos
2018-04-01
The American Psychiatric Association and the World Health Organization provide distinct trauma-based diagnoses in the fifth edition of the Diagnostic and Statistical Manual (DSM-5), and the forthcoming 11th version of the International Classification of Diseases (ICD-11), respectively. The DSM-5 conceptualizes posttraumatic stress disorder (PTSD) as a single, broad diagnosis, whereas the ICD-11 proposes two "sibling" disorders: PTSD and complex PTSD (CPTSD). The objectives of the current study were to: (a) compare prevalence rates of PTSD/CPTSD based on each diagnostic system; (b) identify clinical and behavioral variables that distinguish ICD-11 CPTSD and PTSD diagnoses; and (c) examine the diagnostic associations for ICD-11 CPTSD and DSM-5 PTSD. Participants in a predominately female clinical sample (N = 106) completed self-report scales to measure ICD-11 PTSD and CPTSD, DSM-5 PTSD, and depression, anxiety, borderline personality disorder, dissociation, destructive behaviors, and suicidal ideation and self-harm. Significantly more people were diagnosed with PTSD according to the DSM-5 criteria (90.4%) compared to those diagnosed with PTSD and CPTSD according to the ICD-11 guidelines (79.8%). An ICD-11 CPTSD diagnosis was distinguished from an ICD-11 PTSD diagnosis by higher levels of dissociation (d = 1.01), depression (d = 0.63), and borderline personality disorder (d = 0.55). Diagnostic associations with depression, anxiety, and suicidal ideation and self-harm were higher for ICD-11 CPTSD compared to DSM-5 PTSD (by 10.7%, 4.0%, and 7.0%, respectively). These results have implications for differential diagnosis and for the development of targeted treatments for CPTSD. Copyright © 2018 International Society for Traumatic Stress Studies.
Paris, Adeline; Deygas, Béatrice; Cornu, Catherine; Thalamas, Claire; Maison, Patrick; Duale, Christian; Kane, Maty; Hodaj, Enkelejda; Cracowski, Jean-Luc
2015-01-01
Aims The aim was to evaluate the comprehension of participants of an improved informed consent document (ICD). Method This was a randomized controlled French multicentre study performed in real conditions. Participants were adult patients undergoing screening for enrolment in biomedical research studies, who agreed to answer a validated questionnaire evaluating objective and subjective comprehension scored from 0 (no comprehension) to 100 (excellent comprehension). Patients were provided either the original ICD or an ICD modified in terms of structure and readability. The primary end point was the score of objective comprehension. The secondary end-points were the enrolment rate in the clinical study and patient characteristics associated with the score of objective comprehension. Results Four hundred and eighty-one patients were included, 241 patients in the original ICD group and 240 patients in the modified ICD group. There was no difference between the two groups for the score of objective comprehension (original ICD 72.7 (95% CI 71.3, 74.1) vs. modified ICD 72.5 (95% CI 71.0, 74.0); P = 0.81). However, the rate of enrolment in the clinical study was lower in the group who received the modified ICD (64.4% (95% CI 58.3, 70.5)) than for the original ICD (73.0% (95% CI 67.4, 78.7)) (P = 0.042). Only female gender and high educational level were associated with a better objective comprehension. Conclusions Improving ICDs had no effect on participants’ understanding, whereas the rate of enrolment was lower in this group. In attempts at improving potential participants’ understanding of clinical research information, efforts and future trials should focus on other ways to improve comprehension. PMID:26147763
Carroll, Sandra L.; Strachan, Patricia H.; de Laat, Sonya; Schwartz, Lisa; Arthur, Heather M.
2011-01-01
Abstract Background Patients are offered implantable defibrillators (ICDs) for the prevention of sudden cardiac death (SCD). However, patients’ decision‐making process (DMP) of whether or not to accept an ICD has not been explored. We asked patients about their decision making when offered an ICD. Design/Setting A grounded theory methodology was employed. Patients were recruited from three ICD centres. Those who received an ICD underwent interviews the first month after implant. Declining patients had interviews at their convenience. In‐depth analysis of transcripts was completed. Identified themes were placed along process pathways in a DMP model and tested. Findings Forty‐four patients consented to participate (25% women). Thirty‐four accepted an ICD and 10 (23%) declined. Ages ranged from 26 to 87 (mean = 65; SD = 12.5). Participants were retired (65%), had ischaemic heart disease (64%) and some post‐secondary education (52%). The DMP was triggered when patient’s risk for SCD was communicated. The physician’s recommendation and a new awareness SCD risk were motivators to accept the ICD. Patient’s decision‐making approaches fell along a continuum, from active and engaged to passive and indifferent. Patient’s approaches were influenced most by the following: (i) trust; (ii) social influences and (iii) health state. Conclusions Health‐care providers need to recognize the DMP pathways in which ICD candidacy and SCD risk are understood. The factors that influence a patient’s decision warrant discussion pre‐implant. It is imperative that patients comprehend the meaning of ICD candidacy to make an informed decision. Participants did not recall alternatives to receiving ICD therapy. PMID:21645190
Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akter, Jesmin; Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp; Islam, Md. Sazzadul
2014-10-10
Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus duringmore » ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.« less
Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias
2016-02-15
Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.
Stephenson, S; Henley, G; Harrison, J; Langley, J
2004-01-01
Objective: To assess the performance of the International Classification of Diseases (ICD) based injury severity score, ICISS, when applied to two versions of the 10th edition of ICD, ICD-10 and ICD-10-AM. Design: ICISS was assessed on its ability to predict threat to life using logistic regression modelling. Models used ICISS and age as predictors and survival as the outcome. Setting: Australia and New Zealand. Patients or subjects: Hospitalisations with an ICD-10-AM principal diagnosis in the range S00–T89 from 1 July 1999 to 30 June 2001 (Australia) or 1 July 1999 to 31 December 2001 (New Zealand). Interventions: None. Main outcome measures: The models were assessed in terms of their discrimination, measured by the concordance score, and calibration, measured using calibration curves and the Hosmer-Lemeshow statistic. Results: 523 633 Australian and 124 767 New Zealand hospitalisations were selected, including 7230 and 1565 deaths respectively. Discrimination was high in all the fitted models with concordance scores of 0.885 to 0.910. Calibration results were also promising with all calibration curves being close to linear, though ICISS appeared to underestimate mortality somewhat for cases with an ICISS score less than 0.6. Overall ICISS performed better when applied to the Australian than the New Zealand hospitalisations. Australian and New Zealand hospitalisations were very similar. ICISS was also only a little more successful when ICD-10-AM rather than mapped ICD-10 was used. Conclusions: ICISS appears to be a reasonable way to estimate severity for databases using ICD-10 or ICD-10-AM. It is also likely to work well for other clinical variants of ICD-10. PMID:15583261
Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P
2015-10-01
Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.
Boyd, Andrew D; Li, Jianrong ‘John’; Burton, Mike D; Jonen, Michael; Gardeux, Vincent; Achour, Ikbel; Luo, Roger Q; Zenku, Ilir; Bahroos, Neil; Brown, Stephen B; Vanden Hoek, Terry; Lussier, Yves A
2013-01-01
Objective Applying the science of networks to quantify the discriminatory impact of the ICD-9-CM to ICD-10-CM transition between clinical specialties. Materials and Methods Datasets were the Center for Medicaid and Medicare Services ICD-9-CM to ICD-10-CM mapping files, general equivalence mappings, and statewide Medicaid emergency department billing. Diagnoses were represented as nodes and their mappings as directional relationships. The complex network was synthesized as an aggregate of simpler motifs and tabulation per clinical specialty. Results We identified five mapping motif categories: identity, class-to-subclass, subclass-to-class, convoluted, and no mapping. Convoluted mappings indicate that multiple ICD-9-CM and ICD-10-CM codes share complex, entangled, and non-reciprocal mappings. The proportions of convoluted diagnoses mappings (36% overall) range from 5% (hematology) to 60% (obstetrics and injuries). In a case study of 24 008 patient visits in 217 emergency departments, 27% of the costs are associated with convoluted diagnoses, with ‘abdominal pain’ and ‘gastroenteritis’ accounting for approximately 3.5%. Discussion Previous qualitative studies report that administrators and clinicians are likely to be challenged in understanding and managing their practice because of the ICD-10-CM transition. We substantiate the complexity of this transition with a thorough quantitative summary per clinical specialty, a case study, and the tools to apply this methodology easily to any clinical practice in the form of a web portal and analytic tables. Conclusions Post-transition, successful management of frequent diseases with convoluted mapping network patterns is critical. The http://lussierlab.org/transition-to-ICD10CM web portal provides insight in linking onerous diseases to the ICD-10 transition. PMID:23645552
Kryzhevoi, Nikolai V; Mateo, David; Pi, Martí; Barranco, Manuel; Cederbaum, Lorenz S
2013-11-07
Interatomic Coulombic decay (ICD) represents an efficient electronic relaxation mechanism of an ionized or an excited system embedded in an environment. The type of this environment and its size have a great impact on the ICD performance. It is stressed that ICD is sensitive to the arrangement of neighboring atoms when the initially created vacancy has a polarization direction. This is demonstrated in the present paper for the case of a 3p-ionized Ca surrounded by He atoms. Useful explicit expressions are derived for the ICD widths which show that the neighbors located along the polarization direction of the ionized orbital have the largest contribution to the ICD rate. By comparison with ab initio results for small clusters, we also show that in a helium environment, the pairwise approximation represents a reliable approach for computing ICD widths. Using this approximation and the density distribution of the helium atoms obtained within density functional theory, we explore ICD in large isotopically mixed helium droplets doped with Ca. A special emphasis is given to the difference between the ICD widths for the Ca3p orbitals directed perpendicular and parallel to the droplet surface. Depending on the size and isotopic composition of the droplet, Ca resides in the interfacial layer between the (4)He core and the (3)He outer shell. Hence, ICD studies in these droplets may provide valuable information on the properties of this interface.
Lee, Mei Ching; Sulmasy, Daniel P; Gallo, Joseph; Kub, Joan; Hughes, Mark T; Russell, Stuart; Kellogg, Anela; Owens, Sharon G; Terry, Peter; Nolan, Marie T
2017-07-01
Many patients with advanced heart failure (HF) experience the life-extending benefits of implantable cardioverter-defibrillators (ICD), but at the end stage of HF, patients may experience shocks with increasing frequency and change the plan for end-of-life (EOL) care including the deactivation of the ICD. This report describes family members' experiences of patients with ICD making decisions at EOL. Understanding the decision-making of patients with ICD at EOL can promote informed decision-making and improve the quality of EOL care. This pilot study used a mixed methods approach to test the effects of a nurse-guided discussion in decision-making about ICD deactivation (turning off the defibrillation function) at the EOL. Interviews were conducted, audiotaped, and transcribed in 2012 to 2013 with 6 family members of patients with advanced HF and ICDs. Three researchers coded the data and identified themes in 2014. Three main themes described family members' experiences related to patients having HF with ICDs making health-care decision at EOL: decision-making preferences, patients' perception on ICD deactivation, and communication methods. Health-care providers need to have knowledge of patients' decision-making preferences. Preferences for decision-making include the allowing of appropriate people to involve and encourages direct conversation with family members even when advance directives is completed. Information of ICD function and the option of deactivation need to be clearly delivered to patients and family members. Education and guidelines will facilitate the communication of the preferences of EOL care.
Roland, Carl L; Lake, Joanita; Oderda, Gary M
2016-12-01
We conducted a systematic review to evaluate worldwide human English published literature from 2009 to 2014 on prevalence of opioid misuse/abuse in retrospective databases where International Classification of Diseases (ICD) codes were used. Inclusion criteria for the studies were use of a retrospective database, measured abuse, dependence, and/or poisoning using ICD codes, stated prevalence or it could be derived, and documented time frame. A meta-analysis was not performed. A qualitative narrative synthesis was used, and 16 studies were included for data abstraction. ICD code use varies; 10 studies used ICD codes that encompassed all three terms: abuse, dependence, or poisoning. Eight studies limited determination of misuse/abuse to an opioid user population. Abuse prevalence among opioid users in commercial databases using all three terms of ICD codes varied depending on the opioid; 21 per 1000 persons (reformulated extended-release oxymorphone; 2011-2012) to 113 per 1000 persons (immediate-release opioids; 2010-2011). Abuse prevalence in general populations using all three ICD code terms ranged from 1.15 per 1000 persons (commercial; 6 months 2010) to 8.7 per 1000 persons (Medicaid; 2002-2003). Prevalence increased over time. When similar ICD codes are used, the highest prevalence is in US government-insured populations. Limiting population to continuous opioid users increases prevalence. Prevalence varies depending on ICD codes used, population, time frame, and years studied. Researchers using ICD codes to determine opioid abuse prevalence need to be aware of cautions and limitations.
Preparing your organization's training program for ICD-10.
Carolan, Katie; Reitzel, David
2011-10-01
Training for ICD-10 is going to be expensive, though predictions of how expensive vary widely. Healthcare finance executives should create a flexible, multiyear capital and operating budget to prepare for ICD-10 conversion and the training and support that will be required. Healthcare organizations also should assess staff knowledge in the critical ICD-10 areas and begin training now to be ready for go-live by early 2013.
The impact of proposed changes to ICD-11 on estimates of PTSD prevalence and comorbidity.
Wisco, Blair E; Miller, Mark W; Wolf, Erika J; Kilpatrick, Dean; Resnick, Heidi S; Badour, Christal L; Marx, Brian P; Keane, Terence M; Rosen, Raymond C; Friedman, Matthew J
2016-06-30
The World Health Organization's posttraumatic stress disorder (PTSD) work group has published a proposal for the forthcoming edition of the International Classification of Diseases (ICD-11) that would yield a very different diagnosis relative to DSM-5. This study examined the impact of the proposed ICD-11 changes on PTSD prevalence relative to the ICD-10 and DSM-5 definitions and also evaluated the extent to which these changes would accomplish the stated aim of reducing the comorbidity associated with PTSD. Diagnostic prevalence estimates were compared using a U.S. national community sample and two U.S. Department of Veterans Affairs clinical samples. The ICD-11 definition yielded prevalence estimates 10-30% lower than DSM-5 and 25% and 50% lower than ICD-10 with no reduction in the prevalence of common comorbidities. Findings suggest that by constraining the diagnosis to a narrower set of symptoms, the proposed ICD-11 criteria set would substantially reduce the number of individuals with the disorder. These findings raise doubt about the extent to which the ICD-11 proposal would achieve the aim of reducing comorbidity associated with PTSD and highlight the public health and policy implications of such a redefinition. Published by Elsevier Ireland Ltd.
Simpson, Helen Blair; Reddy, Y. C. Janardhan
2016-01-01
Since the approval of the ICD-10 by the World Health Organization (WHO) in 1990, global research on obsessive-compulsive disorder (OCD) has expanded dramatically. This article evaluates what changes may be needed to enhance the scientific validity, clinical utility, and global applicability of OCD diagnostic guidelines in preparation for ICD-11. Existing diagnostic guidelines for OCD were compared. Key issues pertaining to clinical description, differential diagnosis, and specifiers were identified and critically reviewed on the basis of the current literature. Specific modifications to ICD guidelines are recommended, including: clarifying the definition of obsessions (i.e., that obsessions can be thoughts, images, or impulses/urges) and compulsions (i.e., clarifying that these can be behaviors or mental acts and not calling these “stereotyped”); stating that compulsions are often associated with obsessions; and removing the ICD-10 duration requirement of at least 2 weeks. In addition, a diagnosis of OCD should no longer be excluded if comorbid with Tourette syndrome, schizophrenia, or depressive disorders. Moreover, the ICD-10 specifiers (i.e., predominantly obsessional thoughts, compulsive acts, or mixed) should be replaced with a specifier for insight. Based on new research, modifications to the ICD-10 diagnostic guidelines for OCD are recommended for ICD-11. PMID:25388607
Chung, Cecilia P; Rohan, Patricia; Krishnaswami, Shanthi; McPheeters, Melissa L
2013-12-30
To review the evidence supporting the validity of billing, procedural, or diagnosis code, or pharmacy claim-based algorithms used to identify patients with rheumatoid arthritis (RA) in administrative and claim databases. We searched the MEDLINE database from 1991 to September 2012 using controlled vocabulary and key terms related to RA and reference lists of included studies were searched. Two investigators independently assessed the full text of studies against pre-determined inclusion criteria and extracted the data. Data collected included participant and algorithm characteristics. Nine studies reported validation of computer algorithms based on International Classification of Diseases (ICD) codes with or without free-text, medication use, laboratory data and the need for a diagnosis by a rheumatologist. These studies yielded positive predictive values (PPV) ranging from 34 to 97% to identify patients with RA. Higher PPVs were obtained with the use of at least two ICD and/or procedure codes (ICD-9 code 714 and others), the requirement of a prescription of a medication used to treat RA, or requirement of participation of a rheumatologist in patient care. For example, the PPV increased from 66 to 97% when the use of disease-modifying antirheumatic drugs and the presence of a positive rheumatoid factor were required. There have been substantial efforts to propose and validate algorithms to identify patients with RA in automated databases. Algorithms that include more than one code and incorporate medications or laboratory data and/or required a diagnosis by a rheumatologist may increase the PPV. Copyright © 2013 Elsevier Ltd. All rights reserved.
The Latent Class Structure of Chinese Patients with Eating Disorders in Shanghai.
Zheng, Yuchen; Kang, Qing; Huang, Jiabin; Jiang, Wenhui; Liu, Qiang; Chen, Han; Fan, Qing; Wang, Zhen; Chen, Jue; Xiao, Zeping
2017-08-25
Eating disorder is culture related, and the clinical symptoms are different between eastern and western patients. So the validity of feeding and eating disorders in the upcoming ICD-11 guide for Chinese patients is unclear. To explore the latent class structure of Chinese patients with eating disorder and the cross-cultural validity of the eating disorder section of the new ICD-11 guide in China. A total of 379 patients with eating disorders at Shanghai Mental Health Center were evaluated using the EDI questionnaire and a questionnaire developed by researchers from 2010 to 2016. SPSS 20.0 was used to enter data and analyze demographic data, and Latent GOLD was employed to conduct latent profile analysis. According to the results of latent profile analysis, patients with eating disorder were divided into five classes: low-weight fasting class (23.1%), non-fat-phobic binge/purge class (21.54%), low-fat-phobic binge class (19.27%), fat-phobic binge class (19.27%), and non-fat-phobic low-weight class (16.76%). Among the clinical symptoms extracted, there were significant differences in Body Mass Index (BMI), binge eating behavior, self-induced vomiting, laxative use and fat-phobic opinion; while there was no significant difference in restrictive food intake. Based on the clinical symptoms, there are five latent classes in Chinese patients with eating disorder, which is in accordance with the diagnostic categories of feeding and eating disorder in ICD-11. However, further work is needed in improving the fat-phobic opinion of patients with eating disorder and clarifying the BMI standard of thinness in the Chinese population.
Physicians’ Outlook on ICD-10-CM/PCS and Its Effect on Their Practice
Watzlaf, Valerie; Alkarwi, Zahraa; Meyers, Sandy; Sheridan, Patty
2015-01-01
Background The United States is one of the last countries to change from ICD-9-CM to ICD-10-CM/PCS. The compliance date for implementation of ICD-10-CM/PCS is expected to fall on October 1, 2015. Objectives Evaluate physicians’ perceptions on the change from ICD-9-CM to ICD-10-CM/PCS and its effect on their practice, determine how HIM professionals can assist in this transition, and assess what resources are needed to aid in the transition. Results Twenty physicians were asked to participate in one of three focus groups. Twelve physicians (60 percent) agreed to participate. Top concerns included electronic health record software readiness, increase in documentation specificity and time, ability of healthcare professionals to learn a new language, and inadequacy of current training methods and content. Conclusion Physicians expressed that advantages of ICD-10-CM/PCS were effective data analytics and complexity of patient cases with more specific codes. Health information management professionals were touted as needed during the transition to create simple, clear specialty guides and crosswalks as well as education and training tools specific for physicians. PMID:26807074
Electromagnetic interference of dental equipment with implantable cardioverter defibrillators.
Dadalti, Manoela Teixeira de Sant'Anna; da Cunha, Antônio José Ledo Alves; Araújo, Marcos César Pimenta de; Moraes, Luis Gustavo Belo de; Risso, Patrícia de Andrade
2017-11-01
Implantable cardioverter defibrillators (ICDs) are subject to electromagnetic interference (EMI). The aim of this study was to assess both the EMI of dental equipments with ICDs and related factors. High- and low-speed handpieces, an electric toothbrush, an implant motor and two types of ultrasonic devices were tested next to an ICD with different sensitivity settings. The ICD was immersed in a saline solution with electrical resistance of 400-800 ohms to simulate the resistance of the human body. The dental equipments were tested in both horizontal (0°) and vertical (90°) positions in relation to the components of the ICD. The tests were performed with a container containing saline solution, which was placed on a dental chair in order to assess the cumulative effect of electromagnetic fields. The dental chair, high- and low-speed handpieces, electric toothbrush, implant motor and ultrasonic devices caused no EMI with the ICD, irrespective of the program set-up or positioning. No cumulative effect of electromagnetic fields was verified. The results of this study suggest that the devices tested are safe for use in patients with an ICD.
Medium voltage therapy for preventing and treating asystole and PEA in ICDs.
Gilman, Byron L; Brewer, James E; Kroll, Kai; Kroll, Mark W
2009-01-01
Sudden cardiac death (SCD) takes up to 500,000 lives each year before a victim can even be treated. To address this the implantable cardioverter defibrillator (ICD) was developed to treat those identified at high risk of SCD. Unfortunately, there are a significant number of cases in which the ICD does not successfully return a victim to normal rhythm and effective perfusion of the blood. The vast majority of cases that are not responsive to the ICD therapy require cardio-pulmonary resuscitation (CPR) according to current resuscitation guidelines. A novel electrical stimulus called medium voltage therapy (MVT) has shown efficacy in producing coronary and carotid blood flow during ventricular fibrillation. This report presents the case that the same stimulus may be effective and feasible for use in ICD patients that do not respond to their ICD therapy, or do not have a rhythm in which, an ICD shock is indicated. The inclusion of MVT technology in implantable devices may be effective in preparing the heart for successful defibrillation or in improving the metabolic condition of the heart to the extent that a pulsatile rhythm may spontaneously develop.
Orgeron, Gabriela M; James, Cynthia A; Te Riele, Anneline; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Kamel, Ihab R; Zimmerman, Stephan L; Judge, Daniel P; Crosson, Jane; Tandri, Harikrishna; Calkins, Hugh
2017-06-06
Arrhythmogenic right ventricular dysplasia/cardiomyopathy is characterized by ventricular arrhythmias and sudden cardiac death. Once the diagnosis is established, risk stratification to determine whether implantable cardioverter-defibrillator (ICD) placement is warranted is critical. The cohort included 312 patients (163 men, age at presentation 33.6±13.9 years) with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy who received an ICD. Over 8.8±7.33 years, 186 participants (60%) had appropriate ICD therapy and 58 (19%) had an intervention for ventricular fibrillation/flutter. Ventricular tachycardia at presentation (hazard ratio [HR]: 1.86; 95% confidence interval [CI], 1.38-2.49; P <0.001), inducibility on electrophysiology study (HR: 3.14; 95% CI, 1.95-5.05; P <0.001), male sex (HR: 1.62; 95% CI, 1.20-2.19; P =0.001), inverted T waves in ≥3 precordial leads (HR: 1.66; 95% CI, 1.09-2.52; P =0.018), and premature ventricular contraction count ≥1000/24 hours (HR: 2.30; 95% CI, 1.32-4.00; P =0.003) were predictors of any appropriate ICD therapy. Inducibility at electrophysiology study (HR: 2.28; 95% CI, 1.10-4.70; P =0.025) remained as the only predictor after multivariable analysis. The predictors for ventricular fibrillation/flutter were premature ventricular contraction ≥1000/24 hours (HR: 4.39; 95% CI, 1.32-14.61; P =0.016), syncope (HR: 1.85; 95% CI, 1.10-3.11; P =0.021), aged ≤30 years at presentation (HR: 1.76; 95% CI, 1.04-3.00; P <0.036), and male sex (HR: 1.73; 95% CI, 1.01-2.97; P =0.046). Younger age at presentation (HR: 3.14; 95% CI, 1.32-7.48; P =0.010) and high premature ventricular contraction burden (HR: 4.43; 95% CI, 1.35-14.57; P <0.014) remained as independent predictors of ventricular fibrillation/flutter. Complications occurred in 66 participants (21%), and 64 (21%) had inappropriate ICD interventions. Overall mortality was low at 2%, and 4% underwent heart transplantation. These findings represent an important step in identifying predictors of ICD therapy for potentially fatal ventricular fibrillation/flutter and should be considered when developing a risk stratification model for arrhythmogenic right ventricular dysplasia/cardiomyopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Living with hypertrophic cardiomyopathy and an implantable defibrillator.
Magnusson, Peter; Jonsson, Jessica; Mörner, Stellan; Fredriksson, Lennart
2017-05-10
ICDs efficiently terminate life-threatening arrhythmias, but complications occur during long-term follow-up. Patients' own perspective is largely unknown. The aim of the study was to describe experiences of hypertrophic cardiomyopathy (HCM) patients with implantable defibrillators (ICDs). We analyzed 26 Swedish patient interviews using hermeneutics and latent content analysis. Patients (aged 27-76 years) were limited by HCM especially if it deteriorates into heart failure. The ICD implies safety, gratitude, and is accepted as a part of the body even when inappropriate ICD shocks are encountered. Nobody regretted the implant. Both the disease and the ICD affected professional life and leisure time activities, especially at younger ages. Family support was usually strong, but sometimes resulted in overprotection, whereas health care focused on medical issues. Despite limitations, patients adapted, accepted, and managed challenges. HCM patients with ICDs reported good spirit and hope even though they had to adapt and accept limitations over time.
[Inappropriate ICD therapies: All problems solved with MADIT-RIT?].
Kolb, Christof
2015-06-01
The MADIT-RIT study represents a major trial in implantable cardioverter-defibrillator (ICD) therapy that was recently published. It highlights that different programming strategies (high rate cut-off or delayed therapy versus conventional) reduce inappropriate ICD therapies, leave syncope rates unaltered and can improve patient's survival. The study should motivate cardiologist and electrophysiologists to reconsider their individual programming strategies. However, as the study represents largely patients with ischemic or dilated cardiomyopathy for primary prevention of sudden cardiac death supplied with a dual chamber or cardiac resynchronisation therapy ICD, the results may not easily be transferable to other entities or other device types. Despite the success of the MADIT-RIT study efforts still need to be taken to further optimise device algorithms to avert inappropriate therapies. Optimised ICD therapy also includes the avoidance of unnecessary ICD shocks as well as the treatment of all aspects of the underlying cardiac disease.
Krueger, Richard B; Reed, Geoffrey M; First, Michael B; Marais, Adele; Kismodi, Eszter; Briken, Peer
2017-07-01
The World Health Organization is currently developing the 11th revision of the International Classifications of Diseases and Related Health Problems (ICD-11), with approval of the ICD-11 by the World Health Assembly anticipated in 2018. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH) was created and charged with reviewing and making recommendations for categories related to sexuality that are contained in the chapter of Mental and Behavioural Disorders in ICD-10 (World Health Organization 1992a). Among these categories was the ICD-10 grouping F65, Disorders of sexual preference, which describes conditions now widely referred to as Paraphilic Disorders. This article reviews the evidence base, rationale, and recommendations for the proposed revisions in this area for ICD-11 and compares them with DSM-5. The WGSDSH recommended that the grouping, Disorders of sexual preference, be renamed to Paraphilic Disorders and be limited to disorders that involve sexual arousal patterns that focus on non-consenting others or are associated with substantial distress or direct risk of injury or death. Consistent with this framework, the WGSDSH also recommended that the ICD-10 categories of Fetishism, Fetishistic Transvestism, and Sadomasochism be removed from the classification and new categories of Coercive Sexual Sadism Disorder, Frotteuristic Disorder, Other Paraphilic Disorder Involving Non-Consenting Individuals, and Other Paraphilic Disorder Involving Solitary Behaviour or Consenting Individuals be added. The WGSDSH's proposals for Paraphilic Disorders in ICD-11 are based on the WHO's role as a global public health agency and the ICD's function as a public health reporting tool.
Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation.
Dyers, Robin; Ward, Grant; Du Plooy, Shane; Fourie, Stephanus; Evans, Juliet; Mahomed, Hassan
2017-05-24
The proposed National Health Insurance policy for South Africa (SA) requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD) codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2) adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.
An Evaluation of Comparability between NEISS and ICD-9-CM Injury Coding
Thompson, Meghan C.; Wheeler, Krista K.; Shi, Junxin; Smith, Gary A.; Xiang, Huiyun
2014-01-01
Objective To evaluate the National Electronic Injury Surveillance System’s (NEISS) comparability with a data source that uses ICD-9-CM coding. Methods A sample of NEISS cases from a children’s hospital in 2008 was selected, and cases were linked with their original medical record. Medical records were reviewed and an ICD-9-CM code was assigned to each case. Cases in the NEISS sample that were non-injuries by ICD-9-CM standards were identified. A bridging matrix between the NEISS and ICD-9-CM injury coding systems, by type of injury classification, was proposed and evaluated. Results Of the 2,890 cases reviewed, 13.32% (n = 385) were non-injuries according to the ICD-9-CM diagnosis. Using the proposed matrix, the comparability of the NEISS with ICD-9-CM coding was favorable among injury cases (κ = 0.87, 95% CI: 0.85–0.88). The distribution of injury types among the entire sample was similar for the two systems, with percentage differences ≥1% for only open wounds or amputation, poisoning, and other or unspecified injury types. Conclusions There is potential for conducting comparable injury research using NEISS and ICD-9-CM data. Due to the inclusion of some non-injuries in the NEISS and some differences in type of injury definitions between NEISS and ICD-9-CM coding, best practice for studies using NEISS data obtained from the CPSC should include manual review of case narratives. Use of the standardized injury and injury type definitions presented in this study will facilitate more accurate comparisons in injury research. PMID:24658100
Sheppard, Richard; Mather, Paul J; Alexis, Jeffrey D; Starling, Randall C; Boehmer, John P; Thohan, Vinay; Pauly, Daniel F; Markham, David W; Zucker, Mark; Kip, Kevin E; McNamara, Dennis M
2012-09-01
Given the potential for recovery in recent onset nonischemic cardiomyopathy (ROCM), the timing and need for implantable cardioverter-defibrillator (ICDs) remains controversial. We examined the utilization of ICDs and the impact on survival for subjects with ROCM. An National Heart, Lung, and Blood Institute sponsored registry enrolled 373 subjects with ROCM, all with a left ventricular ejection fraction (LVEF) ≤0.40 and ≤6 months of symptoms. The mean age was 45 ± 14 years, 38% were female, 21% black, 75% New York Heart Association II/III, and the mean LVEF was 0.24 ± 0.08. Survival was comparable for subjects with an ICD within 1 month of entry (n = 43, 1/2/3 year % survival = 97/97/92) and those with no ICD at 1 month (n = 330, % survival = 98/97/95, P = .30) and between those with and without an ICD at 6 months (ICD, n = 73, 1/2/3 year % survival = 98/98/95; no ICD, n = 300, % survival = 98/96/95, P = .95). There were only 6 sudden cardiac deaths (SCD) noted (% survival free from SCD = 99/98/97) and these occurred in 1.9% of subjects without ICD and 0.9% of those with a device (P = .50). In a multicenter cohort of ROCM the risk of SCD was low at 1% per year. Early ICD placement did not impact survival and can be deferred while assessing potential for myocardial recovery. Copyright © 2012 Elsevier Inc. All rights reserved.
An evaluation of comparability between NEISS and ICD-9-CM injury coding.
Thompson, Meghan C; Wheeler, Krista K; Shi, Junxin; Smith, Gary A; Xiang, Huiyun
2014-01-01
To evaluate the National Electronic Injury Surveillance System's (NEISS) comparability with a data source that uses ICD-9-CM coding. A sample of NEISS cases from a children's hospital in 2008 was selected, and cases were linked with their original medical record. Medical records were reviewed and an ICD-9-CM code was assigned to each case. Cases in the NEISS sample that were non-injuries by ICD-9-CM standards were identified. A bridging matrix between the NEISS and ICD-9-CM injury coding systems, by type of injury classification, was proposed and evaluated. Of the 2,890 cases reviewed, 13.32% (n = 385) were non-injuries according to the ICD-9-CM diagnosis. Using the proposed matrix, the comparability of the NEISS with ICD-9-CM coding was favorable among injury cases (κ = 0.87, 95% CI: 0.85-0.88). The distribution of injury types among the entire sample was similar for the two systems, with percentage differences ≥1% for only open wounds or amputation, poisoning, and other or unspecified injury types. There is potential for conducting comparable injury research using NEISS and ICD-9-CM data. Due to the inclusion of some non-injuries in the NEISS and some differences in type of injury definitions between NEISS and ICD-9-CM coding, best practice for studies using NEISS data obtained from the CPSC should include manual review of case narratives. Use of the standardized injury and injury type definitions presented in this study will facilitate more accurate comparisons in injury research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Wen; Jones, Frank E., E-mail: fjones3@tulane.edu
2014-01-10
Highlights: •HER4/4ICD is an obligate coactivator for 37% of estrogen regulated genes. •HER4/4ICD coactivated genes selectively regulate estrogen stimulated proliferation. •Estrogen stimulated tumor cell migration occurs independent of HER4/4ICD. •Disrupting HER4/4ICD and ER coactivated gene expression may suppress breast cancer. -- Abstract: The EGFR-family member HER4 undergoes regulated intramembrane proteolysis (RIP) to generate an intracellular domain (4ICD) that functions as a transcriptional coactivator. Accordingly, 4ICD coactivates the estrogen receptor (ER) and associates with ER at target gene promoters in breast tumor cells. However, the extent of 4ICD coactivation of ER and the functional significance of the 4ICD/ER transcriptional complex ismore » unclear. To identify 4ICD coactivated genes we performed a microarray gene expression analysis of β-estradiol treated cells comparing control MCF-7 breast cancer cells to MCF-7 cells where HER4 expression was stably suppressed using a shRNA. In the MCF-7 cell line, β-estradiol significantly stimulated or repressed by 2-fold or more 726 or 53 genes, respectively. Significantly, HER4/4ICD was an obligate coactivator for 277 or 38% of the β-estradiol stimulated genes. Ingenuity Pathway Analysis of β-estradiol regulated genes identified significant associations with multiple cellular functions regulating cellular growth and proliferation, cell cycle progression, cancer metastasis, decreased hypoplasia, tumor cell migration, apoptotic resistance of tumor cells, and increased transcription. Genes coactivated by 4ICD displayed functional specificity by only significantly contributing to cellular growth and proliferation, cell cycle progression, and decreased hypoplasia. In direct concordance with these in situ results we show that HER4 knockdown in MCF-7 cells results in a loss of estrogen stimulated tumor cell proliferation and cell cycle progression, whereas, estrogen stimulated tumor cell migration was unaffected by loss of HER4 expression. In summary, we demonstrate for the first time that a cell surface receptor functions as an obligate ER coactivator with functional specificity associated with breast tumor cell proliferation and cell cycle progression. Nearly 90% of ER positive tumors coexpress HER4, therefore we predict that the majority of breast cancer patients would benefit from a strategy to therapeutic disengage ER/4ICD coregulated tumor cell proliferation.« less
Silva, Ana F G; Bonatti, Rodolfo; Batatinha, Julio A P; Nearing, Bruce D; Zeng, Dewan; Belardinelli, Luiz; Verrier, Richard L
2017-03-01
We examined the effects of the selective late INa inhibitor eleclazine on the 50% probability of successful defibrillation (DFT50) before and after administration of amiodarone to determine its suitability for use in patients with implantable cardioverter defibrillators (ICDs). In 20 anesthetized pigs, transvenous active-fixation cardiac defibrillation leads were fluoroscopically positioned into right ventricular apex through jugular vein. ICDs were implanted subcutaneously. Dominant frequency of ventricular fibrillation was analyzed by fast Fourier transform. The measurements were made before drug administration (control), and at 40 minutes after vehicle, eleclazine (2 mg/kg, i.v., bolus over 15 minutes), or subsequent/single amiodarone administration (10 mg/kg, i.v., bolus over 10 minutes). Eleclazine did not alter DFT50, dominant frequency, heart rate, or mean arterial pressure (MAP). Subsequent amiodarone increased DFT50 (P = 0.006), decreased dominant frequency (P = 0.022), and reduced heart rate (P = 0.031) with no change in MAP. Amiodarone alone increased DFT50 (P = 0.005; NS compared to following eleclazine) and decreased dominant frequency (P = 0.003; NS compared to following eleclazine). Selective late INa inhibition with eleclazine does not alter DFT50 or dominant frequency of ventricular fibrillation when administered alone or in combination with amiodarone. Accordingly, eleclazine would not be anticipated to affect the margin of defibrillation safety in patients with ICDs.
NASA Technical Reports Server (NTRS)
1976-01-01
The AMPS to Spacelab Interface Control Document which is to be used as a guide for format and information content in generating specific AMPS Mission ICDs is presented. This document is meant to supplement the Spacelab Payload Accommodations Handbook in that it only defines interfaces which are not discussed in the handbook to the level required for design purposes. The AMPS Top Level Requirements Tree, illustrates this ICD by a shaded area and its relationship to the other AMPS technical documents. Other interface documents shown are the Level II, AMPS to Space Shuttle Vehicle ICD and the Level III, AMPS to Instruments ICD.
Makaryus, John N.; Angert-Gilman, Julia; Yacoub, Mena; Patel, Apoor
2014-01-01
Implantable cardioverter-defibrillators (ICDs) are the standard of care for preventing sudden cardiac death in patients who are predisposed to malignant ventricular arrhythmias. Causes of inappropriate ICD shock include equipment malfunction, improper arrhythmia evaluation, misinterpretation of myopotentials, and electromagnetic interference. As the number of implanted ICDs has increased, other contributors to inappropriate therapy have become known, such as minimal electrical current leaks that mimic ventricular fibrillation. We present the case of a 63-year-old man with a biventricular ICD who received 2 inappropriate shocks, probably attributable to alternating-current leaks in a swimming pool. In addition, we discuss ICD sensitivity and offer recommendations to avoid similar occurrences. PMID:24512403
Hyland, P; Shevlin, M; Brewin, C R; Cloitre, M; Downes, A J; Jumbe, S; Karatzias, T; Bisson, J I; Roberts, N P
2017-09-01
The 11th version of the International Classification of Diseases (ICD-11) has proposed two related trauma diagnoses: Post-traumatic stress disorder (PTSD) and Complex PTSD (CPTSD). Using a newly developed, disorder-specific measure of PTSD and CPTSD called the International Trauma Questionnaire (ITQ) the current study will (i) assess the factorial validity of ICD-11 PTSD and CPTSD; (ii) provide the first test of the discriminant validity of these constructs; and (iii) provide the first comparison of ICD-11, and Diagnostic and Statistical Manual, Fifth Edition (DSM-5), PTSD diagnostic rates using disorder-specific measures. ICD-11 and DSM-5 PTSD-specific measures were completed by a British clinical sample of trauma-exposed patients (N = 171). The structure and validity of ICD-11 PTSD and CPTSD were assessed by means of factor analysis and assessing relationships with criterion variables. Diagnostic rates under ICD-11 were significantly lower than those under DSM-5. A two-factor second-order model reflecting the distinction between PTSD and CPTSD best represented the data from the ITQ; and the PTSD and CPTSD factors differentially predicted multiple psychological variables. The factorial and discriminant validity of ICD-11 PTSD and CPTSD was supported, and ICD-11 produces fewer diagnostic cases than DSM-5. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Goodman, M; Hess, B
1999-01-01
Affective symptoms were examined retrospectively in 25 patients following placement of implantable cardioverter defibrillators (ICD) which can produce intermittent shocks without warning in response to cardiac ventricular arrhythmias. The number of ICD random, uncontrollable discharge shocks and pre-ICD history of psychological distress (i.e., depression and/or anxiety) were documented in all patients using a demographics questionnaire and a standardized behavioral/psychological symptoms questionnaire (i.e., Symptom Checklist-90 Revised). ICD patients were dichotomized into two groups: those without a history of psychological distress prior to ICD (n = 18) and those with a history of psychological distress prior to ICD (n = 7). In ICD patients without a prior history, results indicated that quantity of ICD discharge shocks was significantly predictive of current reported depression (r = 0.45, p = 0.03) and current reported anxiety (r = 0.51, p = 0.02). Conversely, in patients with a reported history of psychological distress, there was no significant relationship found between quantity of discharge shocks and current reported depression or anxiety. This study may provide evidence in support of a human model of learned helplessness in that it supports the notion that exposure to an unavoidable and inescapable aversive stimulus was found to be related to patients' reported depression. Further studies may wish to prospectively consider a larger sample as well as a more comprehensive assessment of premorbid psychological symptoms.
Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E
2013-05-28
The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p < 0.0001), with all-cause mortality (hazard ratio: 2.40; 95% confidence interval: 1.62 to 3.54; p < 0.0001), and with a composite of all-cause mortality and appropriate ICD shocks (hazard ratio: 3.03; 95% confidence interval: 2.21 to 4.15; p < 0.0001). RR-NSVT identified on routine ICD interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Implementation of ICD-10 in Canada: how has it impacted coded hospital discharge data?
2012-01-01
Background The purpose of this study was to assess whether or not the change in coding classification had an impact on diagnosis and comorbidity coding in hospital discharge data across Canadian provinces. Methods This study examined eight years (fiscal years 1998 to 2005) of hospital records from the Hospital Person-Oriented Information database (HPOI) derived from the Canadian national Discharge Abstract Database. The average number of coded diagnoses per hospital visit was examined from 1998 to 2005 for provinces that switched from International Classifications of Disease 9th version (ICD-9-CM) to ICD-10-CA during this period. The average numbers of type 2 and 3 diagnoses were also described. The prevalence of the Charlson comorbidities and distribution of the Charlson score one year before and one year after ICD-10 implementation for each of the 9 provinces was examined. The prevalence of at least one of the seventeen Charlson comorbidities one year before and one year after ICD-10 implementation were described by hospital characteristics (teaching/non-teaching, urban/rural, volume of patients). Results Nine Canadian provinces switched from ICD-9-CM to ICD-I0-CA over a 6 year period starting in 2001. The average number of diagnoses coded per hospital visit for all code types over the study period was 2.58. After implementation of ICD-10-CA a decrease in the number of diagnoses coded was found in four provinces whereas the number of diagnoses coded in the other five provinces remained similar. The prevalence of at least one of the seventeen Charlson conditions remained relatively stable after ICD-10 was implemented, as did the distribution of the Charlson score. When stratified by hospital characteristics, the prevalence of at least one Charlson condition decreased after ICD-10-CA implementation, particularly for low volume hospitals. Conclusion In conclusion, implementation of ICD-10-CA in Canadian provinces did not substantially change coding practices, but there was some coding variation in the average number of diagnoses per hospital visit across provinces. PMID:22682405
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashii, Haruko, E-mail: haruko@pmrc.tsukuba.ac.jp; Hashimoto, Takayuki; Okawa, Ayako
2013-03-01
Purpose: Radiation therapy for cancer may be required for patients with implantable cardiac devices. However, the influence of secondary neutrons or scattered irradiation from high-energy photons (≥10 MV) on implantable cardioverter-defibrillators (ICDs) is unclear. This study was performed to examine this issue in 2 ICD models. Methods and Materials: ICDs were positioned around a water phantom under conditions simulating clinical radiation therapy. The ICDs were not irradiated directly. A control ICD was positioned 140 cm from the irradiation isocenter. Fractional irradiation was performed with 18-MV and 10-MV photon beams to give cumulative in-field doses of 600 Gy and 1600 Gy,more » respectively. Errors were checked after each fraction. Soft errors were defined as severe (change to safety back-up mode), moderate (memory interference, no changes in device parameters), and minor (slight memory change, undetectable by computer). Results: Hard errors were not observed. For the older ICD model, the incidences of severe, moderate, and minor soft errors at 18 MV were 0.75, 0.5, and 0.83/50 Gy at the isocenter. The corresponding data for 10 MV were 0.094, 0.063, and 0 /50 Gy. For the newer ICD model at 18 MV, these data were 0.083, 2.3, and 5.8 /50 Gy. Moderate and minor errors occurred at 18 MV in control ICDs placed 140 cm from the isocenter. The error incidences were 0, 1, and 0 /600 Gy at the isocenter for the newer model, and 0, 1, and 6 /600Gy for the older model. At 10 MV, no errors occurred in control ICDs. Conclusions: ICD errors occurred more frequently at 18 MV irradiation, which suggests that the errors were mainly caused by secondary neutrons. Soft errors of ICDs were observed with high energy photon beams, but most were not critical in the newer model. These errors may occur even when the device is far from the irradiation field.« less
Jama, Zimasa V; Chin, Ashley; Mayosi, Bongani M; Badri, Motasim
2015-01-01
Objectives Little is known about the performance of re-used pacemakers and implantable cardioverter defibrillators (ICDs) in Africa. We sought to compare the risk of infection and the rate of malfunction of re-used pacemakers and ICDs with new devices implanted at Groote Schuur Hospital in Cape Town, South Africa. Methods This was a retrospective case comparison study of the performance of re-used pacemakers and ICDs in comparison with new devices implanted at Groote Schuur Hospital over a 10-year period. The outcomes were incidence of device infection, device malfunction, early battery depletion, and device removal due to infection, malfunction, or early battery depletion. Results Data for 126 devices implanted in 126 patients between 2003 and 2013 were analysed, of which 102 (81%) were pacemakers (51 re-used and 51 new) and 24 (19%) were ICDs (12 re-used and 12 new). There was no device infection, malfunction, early battery depletion or device removal in either the re-used or new pacemaker groups over the median follow up of 15.1 months [interquartile range (IQR), 1.3–36.24 months] for the re-used pacemakers, and 55.8 months (IQR, 20.3–77.8 months) for the new pacemakers. In the ICD group, no device infection occurred over a median follow up of 35.9 months (IQR, 17.0–70.9 months) for the re-used ICDs and 45.7 months (IQR, 37.6–53.7 months) for the new ICDs. One device delivered inappropriate shocks, which resolved without intervention and with no harm to the patient. This re-used ICD subsequently needed generator replacement 14 months later. In both the pacemaker and ICD groups, there were no procedure-non-related infections documented for the respective follow-up periods. Conclusion No significant differences were found in performance between re-used and new pacemakers and ICDs with regard to infection rates, device malfunction, battery life and device removal for complications. Pacemaker and ICD re-use is feasible and safe and is a viable option for patients with bradyarrhythmias and tachyarrthythmias. PMID:26407220
[Restrictions for ICD patients in daily life].
Köbe, Julia; Gradaus, Rainer; Zumhagen, Sven; Böcker, Dirk
2005-11-01
Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging (MRI) because of a high risk of destruction of the system with even potential harm to the patient. High-frequency application for electrocautery devices or ablation is possible under certain precautions that have to be planned before. There is a high sensitivity of ICD systems to ionizing radiation with defect of the devices after a cumulative dose > 5 Gy.
Carvajal-Hausdorf, Daniel E; Schalper, Kurt A; Bai, Yalai; Black, Jonathan; Santin, Alessandro D; Rimm, David L
2017-04-01
HER2 overexpression/amplification is identified in up to 40% of uterine serous carcinomas (USC) and 10% of ovarian serous carcinomas (OSC). However, clinical trials using various HER2-targeted agents failed to show significant responses. FDA-approved HER2 assays target only the protein's intracellular domain (ICD) and not the extracellular domain (ECD). Previous quantitative studies in breast cancer by our group have shown that ICD of HER2 is expressed in some cases that do not express the HER2 ECD. We measured HER2 ICD and ECD in USC and OSC samples, and determined their relationship with clinico-pathologic characteristics and survival. We measured HER2 ICD and ECD levels in 2 cohorts of USC and OSC comprising 102 and 175 patients, respectively. HER2 antibodies targeting ICD (CB11) and ECD (SP3) were validated and standardized using the AQUA® method of quantitative immunofluorescence (QIF) and a previously reported HER2 standardization tissue microarray (TMA). Objective, population-based cut-points were used to stratify patients according to HER2 ICD/ECD status. In USC, 8% of patients with high HER2 ICD had low ECD levels (6/75 patients). In OSC, 42% of patients with high HER2 ICD had low ECD levels (29/69 patients). HER2 ICD/ECD status in USC and OSC was not significantly associated with major clinico-pathological features or survival. Using objective, domain-specific HER2 measurement, 8% of USC and 42% of OSC patients with high HER2 ICD levels do not show uniform overexpression of the ECD. This may be related to the presence of p95 HER2, an oncogenic fragment generated by full protein cleavage or alternative initiation of translation. These observations raise the possibility that USC/OSCs expressing low ECD despite being HER2-positive by ICD measurement, may benefit from therapies directed against the intracellular domain (e.g. lapatinib or afatinib) alone or in combination with extracellular domain-directed drugs (e.g. trastuzumab, pertuzumab, T-DM1). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
2010-01-01
Background In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. Methods SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). Results For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease. The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Conclusions Since the frequency of ICD code registration varies between different diagnoses, each diagnosis must be separately validated. Improved frequency and quality of ICD code registration might be achieved by interventions directed towards the physicians where the greatest amount of variation was found. PMID:20416069
Hjerpe, Per; Merlo, Juan; Ohlsson, Henrik; Bengtsson Boström, Kristina; Lindblad, Ulf
2010-04-23
In recent years, several primary care databases recording information from computerized medical records have been established and used for quality assessment of medical care and research. However, to be useful for research purposes, the data generated routinely from every day practice require registration of high quality. In this study we aimed to investigate (i) the frequency and validity of ICD code and drug prescription registration in the new Skaraborg primary care database (SPCD) and (ii) to investigate the sources of variation in this registration. SPCD contains anonymous electronic medical records (ProfDoc III) automatically retrieved from all 24 public health care centres (HCC) in Skaraborg, Sweden. The frequencies of ICD code registration for the selected diagnoses diabetes mellitus, hypertension and chronic cardiovascular disease and the relevant drug prescriptions in the time period between May 2002 and October 2003 were analysed. The validity of data registration in the SPCD was assessed in a random sample of 50 medical records from each HCC (n = 1200 records) using the medical record text as gold standard. The variance of ICD code registration was studied with multi-level logistic regression analysis and expressed as median odds ratio (MOR). For diabetes mellitus and hypertension ICD codes were registered in 80-90% of cases, while for congestive heart failure and ischemic heart disease ICD codes were registered more seldom (60-70%). Drug prescription registration was overall high (88%). A correlation between the frequency of ICD coded visits and the sensitivity of the ICD code registration was found for hypertension and congestive heart failure but not for diabetes or ischemic heart disease.The frequency of ICD code registration varied from 42 to 90% between HCCs, and the greatest variation was found at the physician level (MORPHYSICIAN = 4.2 and MORHCC = 2.3). Since the frequency of ICD code registration varies between different diagnoses, each diagnosis must be separately validated. Improved frequency and quality of ICD code registration might be achieved by interventions directed towards the physicians where the greatest amount of variation was found.
How well do the DSM-5 alcohol use disorder designations map to the ICD-10 disorders?
Hoffmann, Norman G; Kopak, Albert M
2015-04-01
The Diagnostic and Statistical Manual of Mental Disorders, 5th edition (DSM-5), and the International Statistical Classification of Diseases and Related Health Problems, 10th edition (ICD-10), both establish diagnostic criteria for alcohol use disorders. The dimensional severity perspective provided by the DSM-5 may overlap in important ways but also may diverge from the categorical harmful use versus dependence designations presented by the ICD-10. It is especially important to consider the convergence of these 2 diagnostic approaches as the DSM is widely used by clinicians, but the U.S. Centers for Medicare and Medicaid Services has recently required that providers bill for services using the ICD-10 designations. Data from 6,871 male and 801 female admissions to a state prison system were used to compare the DSM-5 severity index for alcohol use disorder to the ICD-10 clinical and research formulations for harmful use and dependence. The DSM-5 and the ICD-10 were highly convergent for the most severe alcohol use disorders and also for those who did not receive a diagnosis. Most DSM-5 moderate alcohol use disorder cases were classified as dependence cases under both the clinical and research ICD criteria. In contrast, there was much more variation in the DSM mild cases. These were divided into categories of harmful use or misuse, depending on whether the clinical or research ICD criteria were applied. Results were similar among male and female inmates. The DSM-5 and ICD-10 exhibit a high level of agreement for cases that would not receive a diagnosis as well as the most severe cases. However, there are important distinctions to be made between the 2 approaches for mild and moderate DSM disorders in addition to harmful use/misuse cases in the ICD. The cases influenced by these discrepancies are most likely to be affected by recently implemented service provider billing practices. Copyright © 2015 by the Research Society on Alcoholism.
Hodgkinson, Kathleen A; Howes, A J; Boland, Paul; Shen, Xiou Seegar; Stuckless, Susan; Young, Terry-Lynn; Curtis, Fiona; Collier, Ashley; Parfrey, Patrick S; Connors, Sean P
2016-03-01
We previously showed a survival benefit of the implantable cardioverter defibrillator (ICD) in males with arrhythmogenic right ventricular cardiomyopathy caused by a p.S358L mutation in TMEM43. We present long-term data (median follow-up 8.5 years) after ICD for primary (PP) and secondary prophylaxis in males and females, determine whether ICD discharges for ventricular tachycardia/ventricular fibrillation were equivalent to an aborted death, and assess relevant clinical predictors. We studied 24 multiplex families segregating an autosomal dominant p.S358L mutation in TMEM43. We compared survival in 148 mutation carriers with an ICD to 148 controls matched for age, sex, disease status, and family. Of 80 male mutation carriers with ICDs (median age at implantation 31 years), 61 (76%) were for PP; of 68 females (median age at implantation 43 years), 66 (97%) were for PP. In males, irrespective of indication, survival was better in the ICD groups compared with control groups (relative risk 9.3 [95% confidence interval 3.3-26] for PP and 9.7 [95% confidence interval 3.2-29.6] for secondary prophylaxis). For PP females, the relative risk was 3.6 (95% confidence interval 1.3-9.5). ICD discharge-free survival for ventricular tachycardia/ventricular fibrillation ≥ 240 beats per minute was equivalent to the control survival rate. Ectopy (≥ 1000 premature ventricular complexes/24 hours) was the only independent clinical predictor of ICD discharge in males, and no predictor was identified in females. ICD therapy is indicated for PP in postpubertal males and in females ≥ 30 years with the p.S358L TMEM43 mutation. ICD termination of rapid ventricular tachycardia/ventricular fibrillation can reasonably be considered an aborted death. © 2016 American Heart Association, Inc.
Temporal trend analysis of nurses' knowledge about implantable cardioverter defibrillators.
Norekvål, Tone M; Peersen, Lene R L; Seivaag, Kirsten; Fridlund, Bengt; Wentzel-Larsen, Tore
2015-05-01
Although crucial, research on nurses' knowledge on the use of implantable cardioverter defibrillators (ICDs) is scant. The aims of the study were to investigate (i) the level of nurses' knowledge on care of patients with ICDs, (ii) whether knowledge level is related to education and type of hospital where nurses practice and (iii) whether knowledge level changes among nurses over time. We developed a questionnaire comprising 27 items in four parts: (1) Sociodemographics, (2) Technical facts about ICDs, (3) Daily life challenges and (4) Self-evaluation of knowledge. After validation, surveys were conducted during 1-week cardiac educational courses in 2003-2010. In total, 463 nurses working in cardiology-related areas participated, yielding a response rate of 91%. Practical and technical knowledge about ICDs was lacking. Nurses were unaware or did not know that mobile phones can affect the device (80%), that patients are restricted from driving heavy vehicles (69%), and that ICDs can deliver unintended shock therapy (73%). However, they were aware that ICD patients can resume sexual (87%) and physical activity (85%). There were few significant differences with regard to education and type of hospital where nurses practiced, but significant time trends in correct answers regarding kitchen appliances, resumption of physical activity and shock delivery. Over an 8-year period, despite the increased usage of ICDs, overall nurses had a lack of knowledge in relation to specific key clinical issues on the care of ICD patients. As a consequence, these patients may fail to receive qualified care. Future research should assess knowledge of other health care professionals and focus on interventions that increase and maintain an appropriate knowledge level in care of ICD patients. Relevance to clinical practice The level of nurses' knowledge on care of patients with ICDs needs to be systematically raised in order to ensure appropriate counselling and nursing care. © 2014 British Association of Critical Care Nurses.
Chen, Chien P; Braunstein, Steve; Mourad, Michelle; Hsu, I-Chow J; Haas-Kogan, Daphne; Roach, Mack; Fogh, Shannon E
2015-01-01
Accurate International Classification of Diseases (ICD) diagnosis coding is critical for patient care, billing purposes, and research endeavors. In this single-institution study, we evaluated our baseline ICD-9 (9th revision) diagnosis coding accuracy, identified the most common errors contributing to inaccurate coding, and implemented a multimodality strategy to improve radiation oncology coding. We prospectively studied ICD-9 coding accuracy in our radiation therapy--specific electronic medical record system. Baseline ICD-9 coding accuracy was obtained from chart review targeting ICD-9 coding accuracy of all patients treated at our institution between March and June of 2010. To improve performance an educational session highlighted common coding errors, and a user-friendly software tool, RadOnc ICD Search, version 1.0, for coding radiation oncology specific diagnoses was implemented. We then prospectively analyzed ICD-9 coding accuracy for all patients treated from July 2010 to June 2011, with the goal of maintaining 80% or higher coding accuracy. Data on coding accuracy were analyzed and fed back monthly to individual providers. Baseline coding accuracy for physicians was 463 of 661 (70%) cases. Only 46% of physicians had coding accuracy above 80%. The most common errors involved metastatic cases, whereby primary or secondary site ICD-9 codes were either incorrect or missing, and special procedures such as stereotactic radiosurgery cases. After implementing our project, overall coding accuracy rose to 92% (range, 86%-96%). The median accuracy for all physicians was 93% (range, 77%-100%) with only 1 attending having accuracy below 80%. Incorrect primary and secondary ICD-9 codes in metastatic cases showed the most significant improvement (10% vs 2% after intervention). Identifying common coding errors and implementing both education and systems changes led to significantly improved coding accuracy. This quality assurance project highlights the potential problem of ICD-9 coding accuracy by physicians and offers an approach to effectively address this shortcoming. Copyright © 2015. Published by Elsevier Inc.
Waks, Jonathan W; Higgins, Angela Y; Mittleman, Murray A; Buxton, Alfred E
2015-03-01
Impaired renal function is associated with increased mortality among patients with implantable cardioverter-defibrillators (ICDs). The relationship between renal function at time of ICD generator replacement and subsequent appropriate ICD therapies is not known. We identified 441 patients who underwent first ICD generator replacement between 2000 and 2011 and had serum creatinine measured within 30 days of their procedure. Patients were divided into tertiles based on estimated glomerular filtration rate (eGFR). Adjusted Cox proportional hazard and competing risk models were used to assess relationships between eGFR and subsequent mortality and appropriate ICD therapy. Median eGFR was 37.6, 59.3, and 84.8 mL/min/1.73 m(2) for tertiles 1-3, respectively. Five-year Kaplan-Meier survival probability was 34.8%, 61.4%, and 84.5% for tertiles 1-3, respectively (P < 0.001). After multivariable adjustment, compared to tertile 3, worse eGFR tertile was associated with increased mortality (HR 2.84, 95% CI [1.36-5.94] for tertile 2; HR 3.84, 95% CI [1.81-8.12] for tertile 1). At 5 years, 57.0%, 58.1%, and 60.2% of patients remained free of appropriate ICD therapy in tertiles 1-3, respectively (P = 0.82). After adjustment, eGFR tertile was not associated with future appropriate ICD therapy. Results were unchanged in an adjusted competing risk model accounting for death. At time of first ICD generator replacement, lower eGFR is associated with higher mortality, but not with appropriate ICD therapies. The poorer survival of ICD patients with reduced eGFR does not appear to be influenced by arrhythmia status, and there is no clear proarrhythmic effect of renal dysfunction, even after accounting for the competing risk of death. © 2014 Wiley Periodicals, Inc.
Rosen, Lisa M.; Liu, Tao; Merchant, Roland C.
2016-01-01
BACKGROUND Blood and body fluid exposures are frequently evaluated in emergency departments (EDs). However, efficient and effective methods for estimating their incidence are not yet established. OBJECTIVE Evaluate the efficiency and accuracy of estimating statewide ED visits for blood or body fluid exposures using International Classification of Diseases, Ninth Revision (ICD-9), code searches. DESIGN Secondary analysis of a database of ED visits for blood or body fluid exposure. SETTING EDs of 11 civilian hospitals throughout Rhode Island from January 1, 1995, through June 30, 2001. PATIENTS Patients presenting to the ED for possible blood or body fluid exposure were included, as determined by prespecified ICD-9 codes. METHODS Positive predictive values (PPVs) were estimated to determine the ability of 10 ICD-9 codes to distinguish ED visits for blood or body fluid exposure from ED visits that were not for blood or body fluid exposure. Recursive partitioning was used to identify an optimal subset of ICD-9 codes for this purpose. Random-effects logistic regression modeling was used to examine variations in ICD-9 coding practices and styles across hospitals. Cluster analysis was used to assess whether the choice of ICD-9 codes was similar across hospitals. RESULTS The PPV for the original 10 ICD-9 codes was 74.4% (95% confidence interval [CI], 73.2%–75.7%), whereas the recursive partitioning analysis identified a subset of 5 ICD-9 codes with a PPV of 89.9% (95% CI, 88.9%–90.8%) and a misclassification rate of 10.1%. The ability, efficiency, and use of the ICD-9 codes to distinguish types of ED visits varied across hospitals. CONCLUSIONS Although an accurate subset of ICD-9 codes could be identified, variations across hospitals related to hospital coding style, efficiency, and accuracy greatly affected estimates of the number of ED visits for blood or body fluid exposure. PMID:22561713
Efficacy and safety of the subcutaneous implantable cardioverter defibrillator: a systematic review.
Chue, Colin Dominic; Kwok, Chun Shing; Wong, Chun Wai; Patwala, Ashish; Barker, Diane; Zaidi, Amir; Mamas, Mamas A; Cunnington, Colin; Ahmed, Fozia Z
2017-09-01
Subcutaneous implantable cardioverter defibrillators (S-ICDs) are considered an alternative to conventional transvenous ICDs (TV-ICDs) in patients not requiring pacing. We searched MEDLINE and EMBASE for studies evaluating efficacy and safety outcomes in S-ICD patients. Outcomes were pooled across studies. Sixteen studies were included with 5380 participants (mean age range 33-56 years). Short-term follow-up data were available for 1670 subjects. The most common complication was pocket infection, affecting 2.7%. Other complications included delayed wound healing (0.6%) and wound discomfort (0.8%). 3.8% of S-ICDs were explanted, most commonly for pocket infection. Mortality rates in hospital (0.4%) and during follow-up (3.4% from 12 studies reporting) were low. Incidence of ventricular arrhythmia varied from 0% to 12%. Overall shock efficacy exceeded 96%. Inappropriate shocks affected 4.3% and was most commonly caused by T-wave oversensing. Although long-term randomised data are lacking, observational data suggest similar shock efficacy and short-term complication rates between the S-ICD and TV-ICD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Piloting a Collaborative Web-Based System for Testing ICD-11.
Donada, Marc; Kostanjsek, Nenad; Della Mea, Vincenzo; Celik, Can; Jakob, Robert
2017-01-01
The 11th revision of the International Classification of Diseases (ICD-11), for the first time in ICD history, deployed web-based collaboration of experts and ICT tools. To ensure that ICD-11 is working well, it needs to be systematically field tested in different settings, across the world. This will be done by means of a number of experiments. In order to support its implementation, a web-based system (ICDfit) has been designed and developed. The present paper illustrates the current prototype of the system and its technical testing. the system has been designed according to WHO requirements, and implemented using PHP and MySQL. Then, a preliminary technical test has been designed and run in January 2016, involving 8 users. They had to carry out double coding, that is, coding case summaries with both ICD-10 and ICD-11, and answering quick questions on the coding difficulty. the 8 users coded 632 cases each, spending an average of 163 seconds per case. While we found an issue in the mechanism used to record coding times, no further issues were found. the proposed system seems to be technically adequate for supporting future ICD-11 testing.
Tanno, Luciana Kase; Calderon, Moises; Linzer, Jeffrey F; Chalmers, Robert J G; Demoly, Pascal
2017-02-10
The International Classification of Diseases (ICD) has been grouping the allergic and hypersensitivity disorders involving the respiratory tract under topographic distribution, regardless of the underlying mechanisms, triggers or concepts currently in use for allergic and hypersensitivity conditions. In order to strengthen awareness and deliberate the creation of the new "Allergic or hypersensitivity disorders involving the respiratory tract" section of the ICD-11, we here propose make the building process public. The new frame has been constructed to cover the gaps previously identified and was based on consensus academic reports and ICD-11 principles. Constant and bilateral discussion was kept with relevant groups representing specialties and resulted in proposals submission into the ICD-11 online platform. The "Allergic or hypersensitivity disorders involving the respiratory tract" section covers 64 entities distributed across five main categories. All the 79 proposals submitted resulted from an intensive collaboration of the Allergy working group, relevant Expert working groups and the WHO ICD governance. The establishment of the ICD-11 "Allergic or hypersensitivity disorders involving the respiratory tract" section will allow the dissemination of the updated concepts to be used in clinical practice by many different specialties and health professionals.
My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?
... ICD How Might an ICD Change My Child's Quality of Life? Young ICD patients are adaptive and often courageous. ... often believe that their children have a lower quality of life than their children actually report. 3 Keeping an ...
Medical Surveillance Monthly Report (MSMR). Volume 22, Number 9, September 2015
2015-09-01
MEDICAL SURVEILLANCE MONTHLY REPORT PAGE 2 PAGE 6 PAGE 12 Assessment of ICD-9-based case definitions for influenza -like illness surveillance...appropriate when there is a need to maximize specifi city. Assessment of ICD-9-based Case Definitions for Influenza -like Illness Surveillance Angelia A. Eick...matched to the spec- imen; if such a match was not possible, T A 8 L E 1. ICD-9 codes for original influenza -like illness case definition ICD-9 code
Della Mea, Vincenzo; Vuattolo, Omar; Frattura, Lucilla; Munari, Flavia; Verdini, Eleonora; Zanier, Loris; Arcangeli, Laura; Carle, Flavia
2015-01-01
In Italy, ICD-9-CM is currently used for coding health conditions at hospital discharge, but ICD-10 is being introduced thanks to the IT-DRG Project. In this project, one needed component is a set of transcoding rules and associated tools for easing coders work in the transition. The present paper illustrates design and development of those transcoding rules, and their preliminary testing on a subset of Italian hospital discharge data.
A compact inflow control device for simulating flight fan noise
NASA Technical Reports Server (NTRS)
Homyak, L.; Mcardle, J. G.; Heidelberg, L. J.
1983-01-01
Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.
Medical Surveillance Monthly Report. Volume 18, Number 10
2011-10-01
encounters were associated with ICD-9 327.23 “obstructive sleep apnea ”. Of the 69,047 individuals with more than one encounter for “obstructive sleep ... apnea ,” the average number of encounters was 6.5. Prior to the introduction of ICD-9 327 in 2005, diagnoses of obstructive sleep apnea (ICD-9...327.23) would have been coded as ICD-9 780.57 “unspecifi ed sleep apnea .” Th e “old” code is still valid and classifi ed under the major diagnostic cat
Burattini, Laura; Man, Sumche; Fioretti, Sandro; Di Nardo, Francesco; Swenne, Cees A
2015-07-01
T-wave alternans (TWA) is a noninvasive index of risk for the occurrence of ventricular arrhythmias. It is known that TWA amplitude (TWAA) increases with heart rate (HR) but how the TWA predictive power varies with HR remains unknown. Thus, the aim of this study was to evaluate the dependency of exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias from HR. TWA was identified using our HR adaptive match filter in exercise ECGs from 248 patients with implanted cardiac defibrillator (ICD), of which 72 developed ventricular tachycardia and/or fibrillation during the 4 year follow-up (ICD_Cases) and 176 did not (ICD_Controls). TWA predictive power was evaluated at HRs from 80 to 120 bpm by computing the area under the receiver operating characteristic curve (AUC) obtained using the maximum TWAA (maxTWAA) and the TWAA ratio (TWAAratio; i.e., the ratio between TWAA at a specific HR and at 80 bpm). TWAA increased with HR. At 80 bpm maxTWAA was lower than at 120 bpm in both ICD_Cases (22 μV vs 41 μV; P < 10(-2) ) and ICD_ Controls (16 μV vs 36 μV; P < 10(-4) ). However, only at 80 bpm ICD_Cases showed significantly higher maxTWAA than ICD_Controls (AUC = 0.6486; P = 0.0080). TWAAratio was higher in ICD_Controls than ICD_Cases for all HR but 120 bpm, and its predictive power was maximum at 115 bpm (AUC = 0.6914; P < 0.05). Exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias, quantified using both maxTWAA and TWAAratio, was higher at low rather than at high HR. © 2014 Wiley Periodicals, Inc.
Caskey, Rachel N; Abutahoun, Angelos; Polick, Anne; Barnes, Michelle; Srivastava, Pavan; Boyd, Andrew D
2018-05-04
The US health care system uses diagnostic codes for billing and reimbursement as well as quality assessment and measuring clinical outcomes. The US transitioned to the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) on October, 2015. Little is known about the impact of ICD-10-CM on internal medicine and medicine subspecialists. We used a state-wide data set from Illinois Medicaid specified for Internal Medicine providers and subspecialists. A total of 3191 ICD-9-CM codes were used for 51,078 patient encounters, for a total cost of US $26,022,022 for all internal medicine. We categorized all of the ICD-9-CM codes based on the complexity of mapping to ICD-10-CM as codes with complex mapping could result in billing or administrative errors during the transition. Codes found to have complex mapping and frequently used codes (n = 295) were analyzed for clinical accuracy of mapping to ICD-10-CM. Each subspecialty was analyzed for complexity of codes used and proportion of reimbursement associated with complex codes. Twenty-five percent of internal medicine codes have convoluted mapping to ICD-10-CM, which represent 22% of Illinois Medicaid patients, and 30% of reimbursements. Rheumatology and Endocrinology had the greatest proportion of visits and reimbursement associated with complex codes. We found 14.5% of ICD-9-CM codes used by internists, when mapped to ICD-10-CM, resulted in potential clinical inaccuracies. We identified that 43% of diagnostic codes evaluated and used by internists and that account for 14% of internal medicine reimbursements are associated with codes which could result in administrative errors.
Infrequent physician use of implantable cardioverter-defibrillators risks patient safety.
Lyman, Stephen; Sedrakyan, Art; Do, Huong; Razzano, Renee; Mushlin, Alvin I
2011-10-01
Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. This cohort (N = 38,992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR = 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.
Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J; Jordaens, Luc; Pedersen, Susanne S
2012-01-01
Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 and 2010, 448 consecutively implanted ICD patients were enrolled in the prospective Mood and personality as precipitants of arrhythmia in patients with an Implantable cardioverter Defibrillator: A prospective Study (MIDAS), of which 429 completed the Hospital Anxiety and Depression Scale (HADS) and the ICD Patient Concerns questionnaire (ICDC) at baseline. Eighty per cent of all patients received beta-blocker therapy. In univariate analysis, beta-blocker therapy was not significantly associated with symptoms of anxiety, depression, and ICD concerns (β = -0.030, β = 0.007, and β = -0.045, respectively; all P's >0.36). Type of beta-blocker showed a trend towards significance for mean levels of ICD concerns (P = 0.09). No association was found between dosage and emotional distress (all P's >0.21). After adjustment for relevant clinical and demographic variables, the association of beta-blocker therapy and symptoms of anxiety, depression, and ICD concerns remained non-significant (β = 0.009, β = 0.037, and β = 0.019, respectively; all P's >0.47). In patients receiving an ICD, beta-blocker therapy was not associated with symptoms of anxiety, depression, and ICD concerns. Research is warranted that further elucidates the link between beta-blocker therapy and emotional distress in this vulnerable patient group.
Fauth-Bühler, Mira; Mann, Karl; Potenza, Marc N
2017-07-01
In light of the upcoming eleventh edition of the International Classification of Diseases (ICD-11), the question arises as to the most appropriate classification of 'Pathological Gambling' ('PG'). Some academic opinion favors leaving PG in the 'Impulse Control Disorder' ('ICD') category, as in ICD-10, whereas others argue that new data especially from the neurobiological area favor allocating it to the category of 'Substance-related and Addictive Disorders' ('SADs'), following the decision in the fifth revision of the Diagnostic and Statistical Manual of Mental Disorders. The current review examines important findings in relation to PG, with the aim of enabling a well-informed decision to be made with respect to the classification of PG as a SAD or ICD in ICD-11. Particular attention is given to cognitive deficits and underlying neurobiological mechanisms that play a role in SADs and ICDs. These processes are impulsivity, compulsivity, reward/punishment processing and decision-making. In summary, the strongest arguments for subsuming PG under a larger SAD category relate to the existence of similar diagnostic characteristics; the high co-morbidity rates between the disorders; their common core features including reward-related aspects (positive reinforcement: behaviors are pleasurable at the beginning which is not the case for ICDs); the findings that the same brain structures are involved in PG and SADs, including the ventral striatum. Research on compulsivity suggests a relationship with PG and SAD, particularly in later stages of the disorders. Although research is limited for ICDs, current data do not support continuing to classify PG as an ICD. © 2016 Society for the Study of Addiction.
Quast, Anne-Floor B E; Tjong, Fleur V Y; Koop, Brendan E; Wilde, Arthur A M; Knops, Reinoud E; Burke, Martin C
2018-02-14
The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and S-ICD orientation. This study is designed to evaluate the orientation of the LP and S-ICD in canine subjects and measure success and threshold of intrabody communication. To gain more human insights, we will explore device orientation in LP and S-ICD patients. Canine subjects implanted with a prototype S-ICD and LP (both Boston Scientific, MA, USA) with anterior-posterior fluoroscopy images were included in this analysis. For comparison, a retrospective analysis of human S-ICD and LP patients was performed. The angle of the long axis of the LP towards the vertical axis of 0°, and distance between the coil and LP were measured. Twenty-three canine subjects were analysed. Median angle of the LP was 29° and median distance of the S-ICD coil to LP was 0.8 cm. All canine subjects had successful communication. The median communicating threshold was 2.5 V. In the human retrospective analysis, 72 LP patients and 100 S-ICD patients were included. The mean angle of the LP was 56° and the median distance between the S-ICD coil and LP was 4.6 cm. Despite the less favourable LP orientation in canine subjects, all communication attempts were successful. In the human subjects, we observed a greater and in theory more favourable LP angle towards the communication vector. These data suggests suitability of human anatomy for conductive intrabody communication.
Reduced dopamine transporter binding predates impulse control disorders in Parkinson's disease.
Vriend, Chris; Nordbeck, Anna H; Booij, Jan; van der Werf, Ysbrand D; Pattij, Tommy; Voorn, Pieter; Raijmakers, Pieter; Foncke, Elisabeth M J; van de Giessen, Elsmarieke; Berendse, Henk W; van den Heuvel, Odile A
2014-06-01
Impulse control disorders (ICD) are relatively common in Parkinson's disease (PD) and generally are regarded as adverse effects of dopamine replacement therapy, although certain demographic and clinical risk factors are also involved. Previous single-photon emission computed tomography (SPECT) studies showed reduced ventral striatal dopamine transporter binding in Parkinson patients with ICD compared with patients without. Nevertheless, these studies were performed in patients with preexisting impulse control impairments, which impedes clear-cut interpretation of these findings. We retrospectively procured follow-up data from 31 medication-naïve PD patients who underwent dopamine transporter SPECT imaging at baseline and were subsequently treated with dopamine replacement therapy. We used questionnaires and a telephone interview to assess medication status and ICD symptom development during the follow-up period (31.5 ± 12.0 months). Eleven patients developed ICD symptoms during the follow-up period, eight of which were taking dopamine agonists. The PD patients with ICD symptoms at follow-up had higher baseline depressive scores and lower baseline dopamine transporter availability in the right ventral striatum, anterior-dorsal striatum, and posterior putamen compared with PD patients without ICD symptoms. No baseline between-group differences in age and disease stage or duration were found. The ICD symptom severity correlated negatively with baseline dopamine transporter availability in the right ventral and anterior-dorsal striatum. The results of this preliminary study show that reduced striatal dopamine transporter availability predates the development of ICD symptoms after dopamine replacement therapy and may constitute a neurobiological risk factor related to a lower premorbid dopamine transporter availability or a more pronounced dopamine denervation in PD patients susceptible to ICD. © 2014 International Parkinson and Movement Disorder Society.
ICARUS study: prevalence and clinical features of impulse control disorders in Parkinson's disease.
Antonini, Angelo; Barone, Paolo; Bonuccelli, Ubaldo; Annoni, Karin; Asgharnejad, Mahnaz; Stanzione, Paolo
2017-04-01
Impulse control disorders/other compulsive behaviours ('ICD behaviours') occur in Parkinson's disease (PD), but prospective studies are scarce, and prevalence and clinical characteristics of patients are insufficiently defined. To assess the presence of ICD behaviours over a 2-year period, and evaluate patients' clinical characteristics. A prospective, non-interventional, multicentre study (ICARUS (Impulse Control disorders And the association of neuRopsychiatric symptoms, cognition and qUality of life in ParkinSon disease); SP0990) in treated Italian PD outpatients. Study visits: baseline, year 1, year 2. Surrogate primary variable: presence of ICD behaviours and five ICD subtypes assessed by modified Minnesota Impulsive Disorder Interview (mMIDI). 1069/1095 (97.6%) patients comprised the Full Analysis Set. Point prevalence of ICD behaviours (mMIDI; primary analysis) was stable across visits: 28.6% (306/1069) at baseline, 29.3% (292/995) at year 1, 26.5% (245/925) at year 2. The most prevalent subtype was compulsive eating, followed by punding, compulsive sexual behaviour, gambling and buying disorder. Patients who were ICD positive at baseline were more likely to be male, younger, younger at PD onset, have longer disease duration, more severe non-motor symptoms (including mood and sexual function), depressive symptoms, sleep impairment and poorer PD-related quality of life. However, they did not differ from the ICD-negative patients in their severity of PD functional disability, motor performance and cognitive function. Prevalence of ICD behaviours was relatively stable across the 2-year observational period. ICD-positive patients had more severe depression, poorer sleep quality and reduced quality of life. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Bates, Jonathan; Parzynski, Craig S; Dhruva, Sanket S; Coppi, Andreas; Kuntz, Richard; Li, Shu-Xia; Marinac-Dabic, Danica; Masoudi, Frederick A; Shaw, Richard E; Warner, Frederick; Krumholz, Harlan M; Ross, Joseph S
2018-06-12
To estimate medical device utilization needed to detect safety differences among implantable cardioverter defibrillators (ICDs) generator models and compare these estimates to utilization in practice. We conducted repeated sample size estimates to calculate the medical device utilization needed, systematically varying device-specific safety event rate ratios and significance levels while maintaining 80% power, testing 3 average adverse event rates (3.9, 6.1, and 12.6 events per 100 person-years) estimated from the American College of Cardiology's 2006 to 2010 National Cardiovascular Data Registry of ICDs. We then compared with actual medical device utilization. At significance level 0.05 and 80% power, 34% or fewer ICD models accrued sufficient utilization in practice to detect safety differences for rate ratios <1.15 and an average event rate of 12.6 events per 100 person-years. For average event rates of 3.9 and 12.6 events per 100 person-years, 30% and 50% of ICD models, respectively, accrued sufficient utilization for a rate ratio of 1.25, whereas 52% and 67% for a rate ratio of 1.50. Because actual ICD utilization was not uniformly distributed across ICD models, the proportion of individuals receiving any ICD that accrued sufficient utilization in practice was 0% to 21%, 32% to 70%, and 67% to 84% for rate ratios of 1.05, 1.15, and 1.25, respectively, for the range of 3 average adverse event rates. Small safety differences among ICD generator models are unlikely to be detected through routine surveillance given current ICD utilization in practice, but large safety differences can be detected for most patients at anticipated average adverse event rates. Copyright © 2018 John Wiley & Sons, Ltd.
Miyake, Christina Y; Webster, Gregory; Czosek, Richard J; Kantoch, Michal J; Dubin, Anne M; Avasarala, Kishor; Atallah, Joseph
2013-06-01
The effectiveness of implantable cardioverter-defibrillator (ICD) therapy for the management of catecholaminergic polymorphic ventricular tachycardia (VT) in young patients is not known. ICD discharges are not always effective and inappropriate discharges are common, both resulting in morbidity and mortality. This is a multicenter, retrospective review of young patients with catecholaminergic polymorphic VT and ICDs from 5 centers. ICD discharges were evaluated to determine arrhythmia mechanism, appropriateness, efficacy of therapy, and complications. A total of 24 patients were included. Median (interquartile range) ages at onset of catecholaminergic polymorphic VT symptoms and ICD implant were 10.6 (5.0-13.8) years and 13.7 (10.7-16.3) years, respectively. Fourteen patients received 140 shocks. Ten patients (42%) experienced 75 appropriate shocks and 11 patients (46%) received 65 inappropriate shocks. On actuarial analysis, freedom from appropriate shock at 1 year after ICD implant was 75%. Of appropriate shocks, only 43 (57%) demonstrated successful primary termination. All successful appropriate ICD discharges were for ventricular fibrillation. No episodes of polymorphic VT or bidirectional VT demonstrated successful primary termination. The adjusted mean (95% confidence interval) cycle length of successful discharges was significantly shorter than unsuccessful discharges (168 [152-184] ms versus 245 [229-262] ms; adjusted P=0.002). Electrical storm occurred in 29% (4/14) and induction of more malignant ventricular arrhythmias in 36% (5/14). There were no deaths. ICD efficacy in catecholaminergic polymorphic VT depends on arrhythmia mechanism. Episodes of ventricular fibrillation were uniformly successfully treated, whereas polymorphic and bidirectional VT did not demonstrate successful primary termination. Inappropriate shocks, electrical storm, and ICD complications were common.
Antonini, A; Chaudhuri, K R; Boroojerdi, B; Asgharnejad, M; Bauer, L; Grieger, F; Weintraub, D
2016-10-01
Dopamine agonists in Parkinson's disease (PD) are associated with impulse control disorders (ICDs) and other compulsive behaviours (together called ICD behaviours). The frequency of ICD behaviours reported as adverse events (AEs) in long-term studies of rotigotine transdermal patch in PD was evaluated. This was a post hoc analysis of six open-label extension studies up to 6 years in duration. Analyses included patients treated with rotigotine for at least 6 months and administered the modified Minnesota Impulse Disorders Interview. ICD behaviours reported as AEs were identified and categorized. For 786 patients, the mean (±SD) exposure to rotigotine was 49.4 ± 17.6 months. 71 (9.0%) patients reported 106 ICD AEs cumulatively. Occurrence was similar across categories: 2.5% patients reported 'compulsive sexual behaviour', 2.3% 'buying disorder', 2.0% 'compulsive gambling', 1.7% 'compulsive eating' and 1.7% 'punding behaviour'. Examining at 6-month intervals, the incidence was relatively low during the first 30 months; it was higher over the next 30 months, peaking in the 54-60-month period. No ICD AEs were serious, and 97% were mild or moderate in intensity. Study discontinuation occurred in seven (9.9%) patients with ICD AEs; these then resolved in five patients. Dose reduction occurred for 23 AEs, with the majority (73.9%) resolving. In this analysis of >750 patients with PD treated with rotigotine, the frequency of ICD behaviour AEs was 9.0%, with a specific incidence timeline observed. Active surveillance as duration of treatment increases may help early identification and management; once ICD behaviours are present rotigotine dose reduction may be considered. © 2016 The Authors. European Journal of Neurology published by John Wiley & Sons Ltd on behalf of European Academy of Neurology.
Diagnostic Stability of ICD/DSM First Episode Psychosis Diagnoses: Meta-analysis
Fusar-Poli, Paolo; Cappucciati, Marco; Rutigliano, Grazia; Heslin, Margaret; Stahl, Daniel; Brittenden, Zera; Caverzasi, Edgardo; McGuire, Philip; Carpenter, William T.
2016-01-01
Background: Validity of current International Classification of Disease/Diagnostic and Statistical Manual of Mental Disorders (ICD/DSM) first episode psychosis diagnoses is essential in clinical practice, research, training and public health. Method: We provide a meta-analytical estimate of prospective diagnostic stability and instability in ICD-10 or DSM-IV first episode diagnoses of functional psychoses. Independent extraction by multiple observers. Random effect meta-analysis conducted with the “metaprop,” “metaninf,” “metafunnel,” “metabias,” and “metareg” packages of STATA13.1. Moderators were tested with meta-regression analyses. Heterogeneity was assessed with the I 2 index. Sensitivity analyses tested robustness of results. Publication biases were assessed with funnel plots and Egger’s test. Findings: 42 studies and 45 samples were included, for a total of 14 484 first episode patients and an average follow-up of 4.5 years. Prospective diagnostic stability ranked: schizophrenia 0.90 (95% CI 0.85–0.95), affective spectrum psychoses 0.84 (95% CI 0.79–0.89), schizoaffective disorder 0.72 (95% CI 0.61–0.73), substance-induced psychotic disorder 0.66 (95% CI 0.51–0.81), delusional disorder 0.59 (95% CI 0.47–0.71), acute and transient psychotic disorder/brief psychotic disorder 0.56 (95% CI 0.62–0.60), psychosis not otherwise specified 0.36 (95% CI 0.27–0.45, schizophreniform disorder 0.29 (95% CI 0.22–0.38). Diagnostic stability within schizophrenia spectrum psychoses was 0.93 (95% CI 0.89–0.97); changes to affective spectrum psychoses were 0.05 (95% CI 0.01–0.08). About 0.10 (95% CI 0.05–0.15) of affective spectrum psychoses changed to schizophrenia spectrum psychosis. Across the other psychotic diagnoses there was high diagnostic instability, mostly to schizophrenia. Interpretation: There is meta-analytical evidence for high prospective diagnostic stability in schizophrenia spectrum and affective spectrum psychoses, with no significant ICD/DSM differences. These results may inform the development of new treatment guidelines for early psychosis and impact drug licensing from regulatory agencies. PMID:26980142
Leisher, Susannah Hopkins; Teoh, Zheyi; Reinebrant, Hanna; Allanson, Emma; Blencowe, Hannah; Erwich, Jan Jaap; Frøen, J Frederik; Gardosi, Jason; Gordijn, Sanne; Gülmezoglu, A Metin; Heazell, Alexander E P; Korteweg, Fleurisca; Lawn, Joy; McClure, Elizabeth M; Pattinson, Robert; Smith, Gordon C S; Tunçalp, Ӧzge; Wojcieszek, Aleena M; Flenady, Vicki
2016-10-05
Each year, about 5.3 million babies die in the perinatal period. Understanding of causes of death is critical for prevention, yet there is no globally acceptable classification system. Instead, many disparate systems have been developed and used. We aimed to identify all systems used or created between 2009 and 2014, with their key features, including extent of alignment with the International Classification of Diseases (ICD) and variation in features by region, to inform the World Health Organization's development of a new global approach to classifying perinatal deaths. A systematic literature review (CINAHL, EMBASE, Medline, Global Health, and PubMed) identified published and unpublished studies and national reports describing new classification systems or modifications of existing systems for causes of perinatal death, or that used or tested such systems, between 2009 and 2014. Studies reporting ICD use only were excluded. Data were independently double-extracted (except from non-English publications). Subgroup analyses explored variation by extent and region. Eighty-one systems were identified as new, modifications of existing systems, or having been used between 2009 and 2014, with an average of ten systems created/modified each year. Systems had widely varying characteristics: (i) comprehensiveness (40 systems classified both stillbirths and neonatal deaths); (ii) extent of use (systems were created in 28 countries and used in 40; 17 were created for national use; 27 were widely used); (iii) accessibility (three systems available in e-format); (iv) underlying cause of death (64 systems required a single cause of death); (v) reliability (10 systems tested for reliability, with overall Kappa scores ranging from .35-.93); and (vi) ICD alignment (17 systems used ICD codes). Regional databases were not searched, so system numbers may be underestimated. Some non-differential misclassification of systems was possible. The plethora of systems in use, and continuing system development, hamper international efforts to improve understanding of causes of death. Recognition of the features of currently used systems, combined with a better understanding of the drivers of continued system creation, may help the development of a truly effective global system.
Potenza, Marc Nicholas; Koran, Lorrin Michael; Pallanti, Stefano
2009-01-01
Impulse control disorders (ICDs) constitute a heterogeneous group of conditions linked diagnostically by difficulties in resisting “the impulse, drive, or temptation to perform an act that is harmful to the person or to others.” Specific ICDs share clinical, phenomenological and biological features with obsessive-compulsive disorder (OCD) that have suggested that these disorders might be categorized together. However, other data suggest significant differences between OCD and ICDs. In this article, clinical, phenomenological and biological features of the formal ICDs are reviewed and compared and contrasted with those of OCD. Available data indicate substantial differences between ICDs and OCD that suggest independent categorizations. Existing research gaps are identified and avenues for future research suggested. PMID:19811840
NASA Technical Reports Server (NTRS)
Mcardle, J. G.; Jones, W. L.; Heidelberg, L. J.; Homyak, L.
1980-01-01
To enable accurate simulation of in-flight fan tone noise during ground static tests, four devices intended to reduce inflow disturbances and turbulence were tested with a JT15D-1 turbofan engine. These inflow control devices (ICD's) consisted of honeycomb/screen structures mounted over the engine inlet. The ICD's ranged from 1.6 to 4 fan diameters in size, and differed in shape and fabrication method. All the ICD's significantly reduced the BPF tone in the far-field directivity patterns, but the smallest ICD's apparently introduced propagating modes which could be recognized by additional lobes in the speeds; at supersonic fan tip speed the smallest ICD's had some measurable loss, but the largest had no loss. Data from a typical transducer show that the unsteady inflow distortion modes (turbulence) were eliminated or significantly reduced when either of the ICD's was installed. However, some steady inflow distortion modes remained.
Al-Khatib, Sana M.; Hellkamp, Anne S.; Fonarow, Gregg C.; Mark, Daniel B.; Curtis, Lesley H.; Hernandez, Adrian F.; Anstrom, Kevin J.; Peterson, Eric D.; Sanders, Gillian D.; Al-Khalidi, Hussein R.; Hammill, Bradley G.; Heidenreich, Paul A.; Hammill, Stephen C.
2014-01-01
IMPORTANCE Clinical trials of prophylactic implantable cardioverter-defibrillators (ICDs) have included a minority of patients with a left ventricular ejection fraction (LVEF) between 30% and 35%. Because a large number of ICDs in the United States are implanted in such patients, it is important to study survival associated with this therapy. OBJECTIVE To characterize patients with LVEF between 30% and 35% and compare the survival of those with and without ICDs. DESIGN, SETTING, AND PARTICIPANTS Retrospective cohort study of Medicare beneficiaries in the National Cardiovascular Data Registry ICD registry (January 1, 2006, through December 31, 2007) with an LVEF between 30% and 35% who received an ICD during a heart failure hospitalization and similar patients in the Get With The Guidelines–Heart Failure (GWTG-HF) database (January 1, 2005, through December 31, 2009) with no ICD. The analysis was repeated in patients with an LVEF less than 30%. There were 3120 patients with an LVEF between 30% and 35% (816 in matched cohorts) and 4578 with an LVEF less than 30% (2176 in matched cohorts). Propensity score matching and Cox models were applied. MAIN OUTCOMES AND MEASURES The primary outcome was all-cause mortality; data were obtained from Medicare claims through December 31, 2011. RESULTS There were no significant differences in the baseline characteristics of the matched groups (n = 408 for both groups). Among patients with an LVEF between 30% and 35%, there were 248 deaths in the ICD Registry group, within a median follow-up of 4.4 years (interquartile range, 2.7-4.9) and 249 deaths in the GWTG HF group, within a median follow-up of 2.9 years (interquartile range, 2.1-4.4). The risk of all-cause mortality in patients with an LVEF between 30% and 35% and an ICD was significantly lower than that in matched patients without an ICD (3-year mortality rates: 51.4% vs 55.0%; hazard ratio, 0.83 [95% CI, 0.69-0.99]; P = .04). Presence of an ICD also was associated with better survival in patients with an LVEF less than 30% (3-year mortality rates: 45.0% vs 57.6%; 634 and 660 total deaths; hazard ratio, 0.72 [95% CI, 0.65-0.81]; P < .001) (P = .20 for interaction). CONCLUSIONS AND RELEVANCE Among Medicare beneficiaries hospitalized for heart failure and with an LVEF between 30% and 35% and less than 30%, survival at 3 years was better in patients who received a prophylactic ICD than in comparable patients with no ICD. These findings support guideline recommendations to implant prophylactic ICDs in eligible patients with an LVEF of 35% or less. PMID:24893088
Bhattacharya, Pratik; Van Stavern, Renee; Madhavan, Ramesh
2010-12-01
Use of resident case logs has been considered by the Residency Review Committee for Neurology of the Accreditation Council for Graduate Medical Education (ACGME). This study explores the effectiveness of a data-mining program for creating resident logs and compares the results to a manual data-entry system. Other potential applications of data mining to enhancing resident education are also explored. Patient notes dictated by residents were extracted from the Hospital Information System and analyzed using an unstructured mining program. History, examination and ICD codes were obtained and compared to the existing manual log. The automated data History, examination, and ICD codes were gathered for a 30-day period and compared to manual case logs. The automated method extracted all resident dictations with the dates of encounter and transcription. The automated data-miner processed information from all 19 residents, while only 4 residents logged manually. The manual method identified only broad categories of diseases; the major categories were stroke or vascular disorder 53 (27.6%), epilepsy 28 (14.7%), and pain syndromes 26 (13.5%). In the automated method, epilepsy 114 (21.1%), cerebral atherosclerosis 114 (21.1%), and headache 105 (19.4%) were the most frequent primary diagnoses, and headache 89 (16.5%), seizures 94 (17.4%), and low back pain 47 (9%) were the most common chief complaints. More detailed patient information such as tobacco use 227 (42%), alcohol use 205 (38%), and drug use 38 (7%) were extracted by the data-mining method. Manual case logs are time-consuming, provide limited information, and may be unpopular with residents. Data mining is a time-effective tool that may aid in the assessment of resident experience or the ACGME core competencies or in resident clinical research. More study of this method in larger numbers of residency programs is needed.
Compulsive behaviors in patients with Parkinson's disease.
Kenangil, Gülay; Ozekmekçi, Sibel; Sohtaoglu, Melis; Erginöz, Ethem
2010-05-01
Several impulse control disorders (ICDs) may develop in patients with Parkinson's disease (PD). We aimed to identify the frequency and phenomenology of ICDs in our PD population. Among 554 PD patients examined in a 3-year period, we identified 33 patients with ICDs. Disease duration, gender, and age-matched 65 PD patients without ICDs were selected as controls. We noted age-at-onset, duration, and severity of PD, dose and types of dopaminergic treatment, as well as presence of motor complications in both groups. Of 554 patients, 33 (5.9%) had ICDs, of whom, 27 were men (81%), mean age-at onset of PD was 48 and disease duration 8 years. While all patients with ICDs were on dopamine agonist drugs (+/- an adjuvant), all but 2 of controls were on dopamine agonists. Punding was the most frequent behavioral problem (57%), 42% exhibited aggressive hypersexuality, 27% compulsive eating, 24% pathologic shopping, and 21% compulsive medication. Severity of PD, presence of l-Dopa-induced motor complications, l-Dopa equivalent doses of dopamine agonists administered were not statistically different between 2 groups. In this study performed in a tertiary clinic for movement disorders in Turkey, several ICDs occurred in a small group of PD patients, mostly in men with young-onset disease, similar to the previous reported series. However, in contrast to the Western series, the number of gamblers was quite low because gambling is illegal in our country. We did not find any association between ICDs and severity of PD as well as doses of dopaminergic agents.
A comparison of DSM-III-R and ICD-10 personality disorder criteria in an out-patient population.
Sara, G; Raven, P; Mann, A
1996-01-01
This study reports the results of a comparison of DSM-III-R and ICD-10 personality disorder criteria by application of both sets of criteria to the same group of patients. Despite the clinical relevance of these disorders and the need for reliable diagnostic criteria, such a comparison has not previously been reported. DSM-III-R and ICD-10 have converged in their classification of personality disorders, but some important differences between the two systems remain. Personality disorder diagnoses from both systems were obtained in 52 out-patients, using the Standardized Assessment of Personality (SAP), a brief, informant-based interview which yields diagnoses in both DSM-III-R and ICD-10. For individual personality disorder diagnoses, agreement between systems was limited. Thirty-four subjects received a personality disorder diagnosis that had an equivalent form in both systems, but only 10 subjects (29%) received the same primary diagnosis in each system. There was a difference in rate of diagnosis, with ICD-10 making significantly more personality disorder diagnoses. The lower diagnostic threshold of the ICD-10 contributed most of this effect. Further modifications in ICD-10 Diagnostic Criteria for Research (DCR) and DSM-IV to the personality disorder category have been considered. The omission in DSM-IV of three categories unique to that system and the raising of the threshold in ICD-10 DCR, do seem to have been helpful in promoting convergence.
Landolina, Maurizio; Curnis, Antonio; Morani, Giovanni; Vado, Antonello; Ammendola, Ernesto; D'onofrio, Antonio; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio
2015-08-01
Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
Furushima, Hiroshi; Chinushi, Masaomi; Iijima, Kenichi; Hasegawa, Kanae; Sato, Akinori; Izumi, Daisuke; Watanabe, Hiroshi; Aizawa, Yoshifusa
2012-05-01
The aim of this study was to determine whether or not the coexistence of sustained ST-segment elevation and abnormal Q waves (STe-Q) could be a risk factor for electrical storm (ES) in implanted cardioverter defibrillator (ICD) patients with structural heart diseases. In all, 156 consecutive patients received ICD therapy for secondary prevention of sudden cardiac death and/or sustained ventricular tachyarrhythmias were included. Electrical storm was defined as ≥3 separate episodes of ventricular tachycardia (VT) and/or ventricular fibrillation (VF) terminated by ICD therapies within 24 h. During a mean follow-up of 1825 ± 1188 days, 42 (26.9%) patients experienced ES, of whom 12 had coronary artery disease, 15 had idiopathic dilated cardiomyopathy, 6 had hypertrophic cardiomyopathy, 4 had arrhythmogenic right ventricular cardiomyopathy, 4 had cardiac sarcoidosis, and 1 had valvular heart disease. Sustained ST-segment elevation and abnormal Q waves in ≥2 leads on the 12-lead electrocardiography was observed in 33 (21%) patients. On the Kaplan-Meier analysis, patients with STe-Q had a markedly higher risk of ES than those without STe-Q (P< 0.0001). The multivariate Cox proportional hazards regression model indicated that STe-Q and left ventricular ejection fraction (LVEF) (<30%) were independent risk factors associated with the recurrence of VT/VF (STe-Q: HR 1.962, 95% CI 1.24-3.12, P= 0.004; LVEF: HR 1.860, 95% CI 1.20-2.89, P= 0.006), and STe-Q was an independent risk factor associated with ES (HR 4.955, 95% CI 2.69-9.13, P< 0.0001). Sustained ST-segment elevation and abnormal Q waves could be a risk factor of not only recurrent VT/VF but also ES in patients with structural heart diseases.
Shock whilst gardening--implantable defibrillators & lawn mowers.
Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C
2014-02-01
Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.
ICD-10: from assessment to remediation to strategic opportunity.
Dugan, John K
2012-02-01
Healthcare finance teams should perform an enterprisewide assessment to determine what ICD-10 means to their organization, strategically, operationally, and financially. CFOs should strategically evaluate the impact of ICD-10 on the organization's entire financial operation. Organizations should have a contingency plan in place across all processes.
BackgroundTrends in gastroenteritis-associated mortality are changing over time with development of antibiotic resistant strains of certain pathogens, improved diagnostic methods, and changing healthcare. In 1999, ICD-10 coding was introduced for mortality records which can also ...
Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K
2010-09-01
Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.
Gittler, Julia K.; Krueger, James G.; Guttman-Yassky, Emma
2014-01-01
Atopic dermatitis (AD), as well as irritant contact dermatitis (ICD) and allergic contact dermatitis (ACD), are common skin diseases. These diseases are characterized by skin inflammation mediated by activated innate immunity or acquired immune mechanisms. Although AD, ICD, and ACD can be encountered in pure forms by allergists and dermatologists, patients with AD often present with increased frequency of ICD and ACD. Although a disturbed barrier alone could potentiate immune reactivity in patients with AD through increased antigen penetration, additional immune mechanisms might explain the increased susceptibility of atopic patients to ICD and ACD. This review discusses cellular pathways associated with increased skin inflammation in all 3 conditions and presents mechanisms that might contribute to the increased rate of ICD and ACD in patients with AD. PMID:22939651
Pedretti, Roberto F E; Curnis, Antonio; Massa, Riccardo; Morandi, Fabrizio; Tritto, Massimo; Manca, Lorenzo; Occhetta, Eraldo; Molon, Giulio; De Ferrari, Gaetano M; Sarzi Braga, Simona; Raciti, Giovanni; Klersy, Catherine; Salerno-Uriarte, Jorge A
2010-08-01
Implantable cardioverter defibrillators (ICD) improve survival in selected patients with left ventricular dysfunction or heart failure (HF). The objective is to estimate the number of ICD candidates and to assess the potential impact on public health expenditure in Italy and the USA. Data from 3513 consecutive patients (ALPHA study registry) were screened. A model based on international guidelines inclusion criteria and epidemiological data was used to estimate the number of eligible patients. A comparison with current ICD implant rate was done to estimate the necessary incremental rate to treat eligible patients within 5 years. Up to 54% of HF patients are estimated to be eligible for ICD implantation. An implantation policy based on guidelines would significantly increase the ICD number to 2671 implants per million inhabitants in Italy and to 4261 in the USA. An annual increment of prophylactic ICD implants of 20% in the USA and 68% in Italy would be necessary to treat all indicated patients in a 5-year timeframe. Implantable cardioverter defibrillator implantation policy based on current evidence may have significant impact on public health expenditure. Effective risk stratification may be useful in order to maximize benefit of ICD therapy and its cost-effectiveness in primary prevention.
Shevlin, M; Hyland, P; Vallières, F; Bisson, J; Makhashvili, N; Javakhishvili, J; Shpiker, M; Roberts, B
2018-02-01
Recently, the American Psychiatric Association (DSM-5) and the World Health Organization (ICD-11) have both revised their formulation of post-traumatic stress disorder (PTSD). The primary aim of this study was to compare DSM-5 and ICD-11 PTSD prevalence and comorbidity rates, as well as the level of disability associated with each diagnosis. This study was based on a representative sample of adult Ukrainian internally displaced persons (IDPs: N = 2203). Post-traumatic stress disorder prevalence was assessed using the PTSD Checklist for DSM-5 and the International Trauma Questionnaire (ICD-11). Anxiety and depression were measured using the Generalized Anxiety Disorder Scale and the Patient Health Questionnaire-Depression. Disability was measured using the WHO Disability Assessment Schedule 2.0. The prevalence of DSM-5 PTSD (27.4%) was significantly higher than ICD-11 PTSD (21.0%), and PTSD rates for females were significantly higher using both criteria. ICD-11 PTSD was associated with significantly higher levels of disability and comorbidity. The ICD-11 diagnosis of PTSD appears to be particularly well suited to identifying those with clinically relevant levels of disability. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cochran, Susan D; Drescher, Jack; Kismödi, Eszter; Giami, Alain; García-Moreno, Claudia; Atalla, Elham; Marais, Adele; Vieira, Elisabeth Meloni; Reed, Geoffrey M
2014-09-01
The World Health Organization is developing the 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11), planned for publication in 2017. The Working Group on the Classification of Sexual Disorders and Sexual Health was charged with reviewing and making recommendations on disease categories related to sexuality in the chapter on mental and behavioural disorders in the 10th revision (ICD-10), published in 1990. This chapter includes categories for diagnoses based primarily on sexual orientation even though ICD-10 states that sexual orientation alone is not a disorder. This article reviews the scientific evidence and clinical rationale for continuing to include these categories in the ICD. A review of the evidence published since 1990 found little scientific interest in these categories. In addition, the Working Group found no evidence that they are clinically useful: they neither contribute to health service delivery or treatment selection nor provide essential information for public health surveillance. Moreover, use of these categories may create unnecessary harm by delaying accurate diagnosis and treatment. The Working Group recommends that these categories be deleted entirely from ICD-11. Health concerns related to sexual orientation can be better addressed using other ICD categories.
Bellis, Jennifer R; Kirkham, Jamie J; Nunn, Anthony J; Pirmohamed, Munir
2014-12-17
National Health Service (NHS) hospitals in the UK use a system of coding for patient episodes. The coding system used is the International Classification of Disease (ICD-10). There are ICD-10 codes which may be associated with adverse drug reactions (ADRs) and there is a possibility of using these codes for ADR surveillance. This study aimed to determine whether ADRs prospectively identified in children admitted to a paediatric hospital were coded appropriately using ICD-10. The electronic admission abstract for each patient with at least one ADR was reviewed. A record was made of whether the ADR(s) had been coded using ICD-10. Of 241 ADRs, 76 (31.5%) were coded using at least one ICD-10 ADR code. Of the oncology ADRs, 70/115 (61%) were coded using an ICD-10 ADR code compared with 6/126 (4.8%) non-oncology ADRs (difference in proportions 56%, 95% CI 46.2% to 65.8%; p < 0.001). The majority of ADRs detected in a prospective study at a paediatric centre would not have been identified if the study had relied on ICD-10 codes as a single means of detection. Data derived from administrative healthcare databases are not reliable for identifying ADRs by themselves, but may complement other methods of detection.
A review of current evidence regarding the ICD-11 proposals for diagnosing PTSD and complex PTSD.
Brewin, Chris R; Cloitre, Marylène; Hyland, Philip; Shevlin, Mark; Maercker, Andreas; Bryant, Richard A; Humayun, Asma; Jones, Lynne M; Kagee, Ashraf; Rousseau, Cécile; Somasundaram, Daya; Suzuki, Yuriko; Wessely, Simon; van Ommeren, Mark; Reed, Geoffrey M
2017-12-01
The World Health Organization's proposals for posttraumatic stress disorder (PTSD) in the 11th edition of the International Classification of Diseases, scheduled for release in 2018, involve a very brief set of symptoms and a distinction between two sibling disorders, PTSD and Complex PTSD. This review of studies conducted to test the validity and implications of the diagnostic proposals generally supports the proposed 3-factor structure of PTSD symptoms, the 6-factor structure of Complex PTSD symptoms, and the distinction between PTSD and Complex PTSD. Estimates derived from DSM-based items suggest the likely prevalence of ICD-11 PTSD in adults is lower than ICD-10 PTSD and lower than DSM-IV or DSM-5 PTSD, but this may change with the development of items that directly measure the ICD-11 re-experiencing requirement. Preliminary evidence suggests the prevalence of ICD-11 PTSD in community samples of children and adolescents is similar to DSM-IV and DSM-5. ICD-11 PTSD detects some individuals with significant impairment who would not receive a diagnosis under DSM-IV or DSM-5. ICD-11 CPTSD identifies a distinct group who have more often experienced multiple and sustained traumas and have greater functional impairment than those with PTSD. Copyright © 2017 Elsevier Ltd. All rights reserved.
Drescher, Jack; Kismödi, Eszter; Giami, Alain; García-Moreno, Claudia; Atalla, Elham; Marais, Adele; Vieira, Elisabeth Meloni; Reed, Geoffrey M
2014-01-01
Abstract The World Health Organization is developing the 11th revision of the International Statistical Classification of Diseases and Related Health Problems (ICD-11), planned for publication in 2017. The Working Group on the Classification of Sexual Disorders and Sexual Health was charged with reviewing and making recommendations on disease categories related to sexuality in the chapter on mental and behavioural disorders in the 10th revision (ICD-10), published in 1990. This chapter includes categories for diagnoses based primarily on sexual orientation even though ICD-10 states that sexual orientation alone is not a disorder. This article reviews the scientific evidence and clinical rationale for continuing to include these categories in the ICD. A review of the evidence published since 1990 found little scientific interest in these categories. In addition, the Working Group found no evidence that they are clinically useful: they neither contribute to health service delivery or treatment selection nor provide essential information for public health surveillance. Moreover, use of these categories may create unnecessary harm by delaying accurate diagnosis and treatment. The Working Group recommends that these categories be deleted entirely from ICD-11. Health concerns related to sexual orientation can be better addressed using other ICD categories. PMID:25378758
Impulse Control and Related Disorders in Parkinson's Disease.
Weintraub, Daniel; Claassen, Daniel O
2017-01-01
Impulse control disorders (ICDs), such as compulsive gambling, buying, sexual, and eating behaviors, are a serious and increasingly recognized complication in Parkinson's disease (PD), occurring in up to 20% of PD patients over the course of their illness. Related behaviors include punding (stereotyped, repetitive, purposeless behaviors), dopamine dysregulation syndrome (DDS) (compulsive medication overuse), and hobbyism (e.g., compulsive internet use, artistic endeavors, and writing). These disorders have a significant impact on quality of life and function, strain interpersonal relationships, and worsen caregiver burden, and are associated with significant psychiatric comorbidity. ICDs have been most closely related to the use of dopamine agonists (DAs), while DDS is primarily associated with shorter acting, higher potency dopamine replacement therapy (DRT), such as levodopa. However, in preliminary research ICDs have also been reported to occur with monoamine oxidase inhibitor-B and amantadine treatment, and after deep brain stimulation (DBS) surgery. Other risk factors for ICDs may include sex (e.g., male sex for compulsive sexual behavior, and female sex for compulsive buying behavior); younger age overall at PD onset; a pre-PD history of an ICD; personal or family history of substance abuse, bipolar disorder, or gambling problems; and impulsive personality traits. Dysregulation of the mesocorticolimbic dopamine system is thought to be the major neurobiological substrate for ICDs in PD, but there is preliminary evidence for alterations in opiate and serotonin systems too. The primary treatment of ICDs in PD is discontinuation of the offending treatment, but not all patients can tolerate this due to worsening motor symptoms or DA withdrawal syndrome. While psychiatric medications and psychosocial treatments are frequently used to treat ICDs in the general population, there is limited empirical evidence for their use in PD, so it is critical for patients to be monitored closely for ICDs from disease onset and routine throughout its course. In the future, it may be possible to use a precision medicine approach to decrease the incidence of ICDs in PD by avoiding DA use in patients determined to be at highest risk based on their clinical and neurobiological (e.g., motor presentation, behavioral measures of medication response, genetics, dopamine transporter neuroimaging) profile. Additionally, as empirically validated treatments for ICDs and similar disorders (e.g., substance use disorders) emerge, it will also be important to examine their efficacy and tolerability in individuals with comorbid PD. © 2017 Elsevier Inc. All rights reserved.
Mortality from idiopathic pulmonary fibrosis: a temporal trend analysis in Brazil, 1979-2014
Algranti, Eduardo; Saito, Cézar Akiyoshi; Silva, Diego Rodrigues Mendonça e; Carneiro, Ana Paula Scalia; Bussacos, Marco Antonio
2017-01-01
ABSTRACT Objective: To analyze mortality from idiopathic pulmonary fibrosis (IPF) in Brazil over the period 1979-2014. Methods: Microdata were extracted from the Brazilian National Ministry of Health Mortality Database. Only deaths for which the underlying cause was coded as International Classification of Diseases version 9 (ICD-9) 515 or 516.3 (until 1995) or as ICD version 10 (ICD-10) J84.1 (from 1996 onward) were included in our analysis. Standardized mortality rates were calculated for the 2010 Brazilian population. The annual trend in mortality rates was analyzed by joinpoint regression. We calculated risk ratios (RRs) by age group, time period of death, and gender, using a person-years denominator. Results: A total of 32,092 deaths were recorded in the study period. Standardized mortality rates trended upward, rising from 0.24/100,000 population in 1979 to 1.10/100,000 population in 2014. The annual upward trend in mortality rates had two inflection points, in 1992 and 2008, separating three distinct time segments with an annual growth of 2.2%, 6.8%, and 2.4%, respectively. The comparison of RRs for the age groups, using the 50- to 54-year age group as a reference, and for the study period, using 1979-1984 as a reference, were 16.14 (14.44-16.36) and 6.71 (6.34-7.12), respectively. Men compared with women had higher standardized mortality rates (per 100,000 person-years) in all age groups. Conclusion: Brazilian IPF mortality rates are lower than those of other countries, suggesting underdiagnosis or underreporting. The temporal trend is similar to those reported in the literature and is not explained solely by population aging. PMID:29340493
Yin, Ling-Ling; Ruan, Su-Hong; Tian, Yu; Zhao, Kai; Xu, Kai Lin
2015-10-01
To clone the variable region genes of human anti-IL1RAP (IL-1 receptor accessory protein) monoclonal antibodies (McAb) and to construct IL1RAP chimeric antigen receptors (CARs). The VH and VL DNA of IL1RAP single chain antibodies were amplified by RACE and overlap extension PCR from total RNA extracted from 3H6E10 and 10D8A7 hybridoma and ligated into specific IL1RAP single-chain variable fragments (scFv). CD8α transmembrane domain, CD137 intracellular domain, TCR ζ chain, human CD8α signal peptide and scFv-anti-IL1RAP were cloned into plasmid LV-lac. Recombinant lentiviruses were generated by co-transfection of recombinant plasmid LV-lac, pMD2. G, and psPAX2 helper vectors into 293FT packing cells. The VH and VL genes of 2 human anti-IL1RAP McAb were acquired. The 3H6E10 VH and VL genes consisted of 402 bp and 393 bp encoding 134 and 131 aminoacid residues, respectively; 10D8A7 VH and VL genes consisted of 423 bp and 381 bp encoding 141 and 127 amine acid residues, respectively. Recombinant expression vertors LV-3H6E10 scFv-ICD and LV-10D8A7 scFv-ICD (ICD: CD8α transmembrane domain-CD137 intracellular domain-TCR ζ chain) were constructed. The target fragments were demonstrated by sequencing analysis. Recombinant plasmids were transfected into 293FT cells and lentiviral particles were acquired. Human anti-IL1RAP recombinant receptors are constructed successfully and lay a good foundation for the construction of IL1RAP-CAR killer T cell vaccine.
Estimated incidence of pertussis in people aged <50 years in the United States
Chen, Chi-Chang; Balderston McGuiness, Catherine; Krishnarajah, Girishanthy; Blanchette, Christopher M.; Wang, Yuanyuan; Sun, Kainan; Buck, Philip O.
2016-01-01
ABSTRACT The introduction of pertussis vaccination in the United States (US) in the 1940s has greatly reduced its burden. However, the incidence of pertussis is difficult to quantify, as many cases are not laboratory-confirmed or reported, particularly in adults. This study estimated pertussis incidence in a commercially insured US population aged <50 years. Data were extracted from IMS' PharMetrics Plus claims database for patients with a diagnosis of pertussis or cough illness using International Classification of Diseases (ICD-9) codes, a commercial outpatient laboratory database for patients with a pertussis laboratory test, and the Centers for Disease Control influenza surveillance database. US national pertussis incidence was projected using 3 methods: (1) diagnosed pertussis, defined as a claim for pertussis (ICD-9 033.0, 033.9, 484.3) during 2008–2013; (2) based on proxy pertussis predictive logistic regression models; (3) using the fraction of cough illness (ICD-9 033.0, 033.9, 484.3, 786.2, 466.0, 466.1, 487.1) attributed to laboratory-confirmed pertussis, estimated by time series linear regression models. Method 1 gave a projected annual incidence of diagnosed pertussis of 9/100,000, which was highest in those aged <1 year. Method 2 gave an average annual projected incidence of 21/100,000. Method 3 gave an overall regression-estimated weighted annual incidence of pertussis of 649/100,000, approximately 58–93 times higher than method 1 depending on the year. These estimations, which are consistent with considerable underreporting of pertussis in people aged <50 years and provide further evidence that the majority of cases go undetected, especially with increasing age, may aid in the development of public health programs to reduce pertussis burden. PMID:27246119
Maercker, Andreas; Znoj, Hansjörg
2010-01-01
Just as traumatic experiences may lead to posttraumatic stress disorder (PTSD) in some individuals, grief may also be a serious health concern for individuals who have experienced bereavement. At present, neither the DSM-IV nor the ICD-10 recognizes any form of grief as a mental disorder. The aim of this review is to summarize recent advances in definition, assessment, prevention, and treatment of complicated grief disorder (CGD) and to compare CGD with PTSD. Four areas are identified to be of importance to clinicians and researchers: (a) the recently proposed consensus criteria of CGD for DSM-V and ICD-11, (b) available assessment instruments, (c) recent prevention and treatment techniques and related effectiveness studies, and (d) emerging disorder models and research on risks and protective factors. This review focuses on the similarities and differences between CGD and PTSD and highlights how a PTSD-related understanding aids the investigation and clinical management of CGD. PMID:22893801
Heyman, Richard E; Slep, Amy M Smith; Foran, Heather M
2015-03-01
Nuanced, multifaceted, and content valid diagnostic criteria for intimate partner violence (IPV) have been created and can be used reliably in the field even by those with little-to-no clinical training/background. The use of such criteria such as these would likely lead to more reliable decision making in the field and more consistency across studies. Further, interrater agreement was higher than that usually reported for individual mental disorders. This paper will provide an overview of (a) IPV's scope and impact; (b) the reliable and valid diagnostic criteria that have been used and the adaptation of these criteria inserted in the latest Diagnostic and Statistical Manual of Mental Disorders (DSM) and another adaptation proposed for the forthcoming International Statistical Classification of Diseases and Related Health Problems (ICD); (c) suggestions for screening of IPV in primary care settings; (d) interventions for IPV; and (e) suggested steps toward globally accepted programs. © 2015 Family Process Institute.
Ajiro, Yoichi; Shiga, Tsuyoshi; Shoda, Morio; Hagiwara, Nobuhisa
2017-03-01
An important step in diagnosing myopotential oversensing is to confirm its reproducibility using specific provocation maneuvers. Although most maneuvers involve the co-contraction of many muscles, no attempt has been made to assess relevant muscle activities by electromyography. We describe a case with an implantable cardioverter defibrillator (ICD) whose myopotential oversensing was provoked by simultaneous straining and leftward twisting. Simultaneous recordings from real-time ICD telemetry and myopotentials of the rectus abdominis, oblique abdominis, and diaphragm on electromyography during the provocation maneuvers were conducted. It was shown that all three muscles contracted simultaneously during the provocation maneuvers; the diaphragm activity was the main source of noise oversensing, and the twist itself caused oversensing possibly due to the change in the position of the lead. In conclusion, the electromyographic assessment of relevant muscle activities may be useful in assessing each muscle's role and its contribution to myopotential oversensing, especially in a patient whose myopotential oversensing requires complex maneuvers to be provoked.
Gillis, Anne M
2014-10-01
The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.
Ascoeta, Maria Soledad; Marijon, Eloi; Defaye, Pascal; Klug, Didier; Beganton, Frankie; Perier, Marie-Cécile; Gras, Daniel; Algalarrondo, Vincent; Deharo, Jean-Claude; Leclercq, Christophe; Fauchier, Laurent; Babuty, Dominique; Bordachar, Pierre; Sadoul, Nicolas; Boveda, Serge; Piot, Olivier
2016-05-01
The lifesaving benefit of implantable cardioverter-defibrillators (ICDs) has been demonstrated. Their use has increased considerably in the past decade, but related complications have become a major concern. The purpose of this study was to assess the incidence and effect on outcomes of early (≤30 days) complications after ICD implantation for primary prevention in a large French population. We analyzed data from 5539 patients from the multicenter French DAI-PP (Défibrillateur Automatique Implantable-Prévention Primaire) registry (2002-2012) who had coronary artery disease or dilated cardiomyopathy and were implanted with an ICD for primary prevention. Overall, early complications occurred in 707 patients (13.5%), mainly related to lead dislodgment or hematoma (57%). Independent factors associated with occurrence of early complications were severe renal impairment (odds ratio [OR] 1.66, 95% confidence interval [CI] 1.17-2.37, P = .02), age ≥75 years (OR 1.01, 95% CI 1.00-1.02, P = .03), cardiac resynchronization therapy (OR 1.58, 95% CI 1.16-2.17, P = .01), and anticoagulant therapy (OR 1.28, 95% CI 1.02-1.61, P = .03). During a mean ± SD follow-up of 3.1 ± 2.3 years, 824 (15.8%) patients experienced ≥1 late complication (>30 days), and 782 (14.9%) patients died. After adjustment, early complications remained associated with occurrence of late complications (OR 2.15, 95% CI 1.73-2.66, P < .0001) and mortality (OR 1.70, 95% CI 1.34-2.17, P = .003). Early complications are common after ICD implantation for primary prevention, occurring in 1 in 7 patients, and are associated with an increased risk of late complications and overall mortality. Further studies are needed to investigate the underlying mechanisms of such associations. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Abisse, Saddam S.; Lampert, Rachel; Burg, Mattew; Soufer, Robert; Shusterman, Vladimir
2011-01-01
Introduction Changes in the autonomic nervous system activity (ANS) are a major trigger of life-threatening ventricular tachyarrhythmias (VTA). Mental arithmetic, a condition administered in a laboratory setting, can provide insight into the ANS effects on cardiac physiology. We examined the responses of cardiac repolarization to laboratory-induced psychological stressors in patients with implantable cardioverter defibrillators (ICDs) with the objective of identifying the indices that differentiate patients with and without subsequent VTA in follow-up. Methods Continuous ECG signals were recorded using 3 standard bipolar (Holter) leads in 56 patients (age: 63.6±11.9, female: 12%, LVEF: 32.3±11) with ICDs during mental arithmetic. The patients were separated into those with subsequent VTA during 3–4 years of follow-up (Group 1: N=9 pts) and those without VTA (Group 2: N=47 pts). Changes in repolarization (QT-interval, mean T-wave amplitude (Tamp), and T-wave area (Tarea) were analyzed during 5min of baseline, stress and recovery. The temporal instability of Tamp and Tarea was examined using the range (Δ) and variance (σ2) of beat-to-beat variations of the corresponding parameters. Results There were no significant differences in HR between the two groups at baseline (61 vs. 63 bpm, p=0.97), during stress (64 vs. 65 bpm, p=0.40), and recovery (62 vs. 61 bpm, p= 0.88). However, during mental stress and post-stress recovery ΔTamp was almost 2-fold greater in Group 1 compared with Group 2 (111 (57–203)) vs. 68 (44–94) μV p=0.04, respectively). Changes in QT-intervals were also greater in Group 1 compared with Group 2 (p=0.02). Conclusion Among patients with ICDs, changes of T-wave amplitude after psychological stress were greater in those with subsequent arrhythmic events. This might signal proarrhythmic repolarization response and help identify patients who would benefit the most from ICD implantation and proactive management. PMID:21920534
Varma, Niraj; Epstein, Andrew E; Schweikert, Robert; Michalski, Justin; Love, Charles J
2016-03-01
The incidence of unscheduled encounters and problem occurrence between ICD implant and first in-person evaluation (IPE) recommended at 12 weeks is unknown. Automatic remote home monitoring (HM) may be useful in this potentially unstable period. ICD patients were randomized 2:1 to HM enabled post-implant (n = 908) or to conventional monitoring (CM; n = 431). Groups were compared between implant and prior to first scheduled IPE for IPE incidence, causes, and actionability (reprogramming, system revision, medication changes) and event detection time. HM and CM patients were similar (mean age 63 years, 72% male, LVEF 29%, primary prevention 73%, DDD 57%). In the post-implant interval assessed (HM 100 ± 21.3 days vs. CM 101 ± 20.8 days, P = 0.54), 85.4% (776/908) HM patients and 87.7% CM (378/431) patients had no cause for IPE (P = 0.31). When IPE occurred, actionability in HM (64/177 [36.2%]) was greater versus CM (15/62 [24.2%], P = 0.12). Actionable items were discovered sooner with HM (P = 0.025). Device reprogramming or lead revision was triggered following 53/177 (29.9%) IPEs in HM versus 9/62 (14.5%) in CM (P = 0.018). Arrhythmia detection was enhanced by HM: 276 atrial and ventricular episodes were detected in 135 follow-ups in contrast to CM (65 episodes at 17 IPEs). More silent arrhythmic episodes were discovered by HM (7.2% vs. 1.5% [P = 0.15]). Since 27/42 (64.3%) IPEs driven by HM alerts were actionable, event notification was a valuable method for problem detection. Importantly, HM did not increase incidence of non-actionable IPEs (P = 0.72). Activation of automatic remote monitoring should be encouraged soon post-ICD implant. © 2015 Wiley Periodicals, Inc.
Marschall, Jonas; Hopkins-Broyles, Diane; Jones, Marilyn; Fraser, Victoria J; Warren, David K
2007-11-01
In 2000, the rate of surgical site infections (SSIs) associated with pacemaker and implantable cardioverter-defibrillator (ICD) procedures performed in the cardiothoracic operating rooms of hospital A was 16% (19 of 116 procedures resulted in infections). This study investigates risks for SSI associated with these procedures in the cardiothoracic operating room. Unmatched 1 : 3 case-control study performed over a 12-month period among patients who had undergone implantation of a pacemaker and/or ICD. A standardized observation scrutinized infection control practices in the area where the procedures were performed. The cardiothoracic operating rooms of hospital A, which belongs to a hospital consortium in the midwestern United States. Patients with SSI were identified as case patients. Control patients were chosen from the group of uninfected patients who had procedures performed during the same period as case patients. A total of 19 SSIs associated with pacemaker and ICD procedures were retrospectively identified among the patients who underwent procedures in these cardiothoracic operating rooms. Culture samples were obtained from 7 patients; 2 yielded coagulase-negative Staphylococcus on culture, 2 yielded Staphylococcus aureus, 1 yielded Serratia marcescens, and 2 showed no growth. In the case-control study, age, race, sex, diabetes mellitus, smoking history, timing of antibiotic therapy, and hair removal did not differ significantly between case patients and control patients. Case patients were more likely to have an abdominal device in place (odds ratio [OR], 5.5 [95% confidence interval {CI}, 1.6-19.3]; P=.006) and less likely to have received a new implant (OR 0.3 [95% CI, 0.1-0.8]; P=.02) or to have had new leads placed (OR, 0.2 [95% CI, 0.1-0.6]; P=.003). Abdominal placement of implanted devices was associated with occurrence of an SSI after pacemaker and/or ICD procedures.
Rück, Christian; Larsson, K Johan; Lind, Kristina; Perez-Vigil, Ana; Isomura, Kayoko; Sariaslan, Amir; Lichtenstein, Paul; Mataix-Cols, David
2015-06-22
The usefulness of cases diagnosed in administrative registers for research purposes is dependent on diagnostic validity. This study aimed to investigate the validity and inter-rater reliability of recorded diagnoses of tic disorders and obsessive-compulsive disorder (OCD) in the Swedish National Patient Register (NPR). Chart review of randomly selected register cases and controls. 100 tic disorder cases and 100 OCD cases were randomly selected from the NPR based on codes from the International Classification of Diseases (ICD) 8th, 9th and 10th editions, together with 50 epilepsy and 50 depression control cases. The obtained psychiatric records were blindly assessed by 2 senior psychiatrists according to the criteria of the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) and ICD-10. Positive predictive value (PPV; cases diagnosed correctly divided by the sum of true positives and false positives). Between 1969 and 2009, the NPR included 7286 tic disorder and 24,757 OCD cases. The vast majority (91.3% of tic cases and 80.1% of OCD cases) are coded with the most recent ICD version (ICD-10). For tic disorders, the PPV was high across all ICD versions (PPV=89% in ICD-8, 86% in ICD-9 and 97% in ICD-10). For OCD, only ICD-10 codes had high validity (PPV=91-96%). None of the epilepsy or depression control cases were wrongly diagnosed as having tic disorders or OCD, respectively. Inter-rater reliability was outstanding for both tic disorders (κ=1) and OCD (κ=0.98). The validity and reliability of ICD codes for tic disorders and OCD in the Swedish NPR is generally high. We propose simple algorithms to further increase the confidence in the validity of these codes for epidemiological research. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Defaye, Pascal; Boveda, Serge; Klug, Didier; Beganton, Frankie; Piot, Olivier; Narayanan, Kumar; Périer, Marie-Cécile; Gras, Daniel; Fauchier, Laurent; Bordachar, Pierre; Algalarrondo, Vincent; Babuty, Dominique; Deharo, Jean-Claude; Leclercq, Christophe; Marijon, Eloi; Sadoul, Nicolas
2017-09-01
Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than single-chamber (SC) ICDs, and compared the long-term outcomes of recipients of each type of device implanted for primary prevention. Between 2002 and 2012, the DAI-PP registry consecutively enrolled 1258 SC- and 1280 DC-ICD recipients at 12 French medical centres. The devices were interrogated at 4- to 6-month intervals during outpatient visits, with a focus on the therapies delivered. The study endpoints were incidence of appropriate therapies, ICD-related morbidity, and deaths from all and from specific causes. The mean age of the SC- and DC-ICD recipients was 59 ± 12 and 62 ± 11 years, respectively (P< 0.0001). The distribution of genders, New York Heart Association functional classes and glomerular filtration rates, and the rates of ischaemic vs. dilated cardiomyopathies and of defibrillation tests at implant, were similar in both study groups. The rates of periprocedural complications were 12.1% in the DC- vs. 8.8% in the SC-ICD groups (P= 0.008). Over a mean follow-up of 3.1 ± 2.2 years, pulse generators were replaced in 21.9% of the DC- vs. 13.6% of the SC-ICD group (P< 0.0001). The proportions of patients treated with ≥1 appropriate therapies (24.7 vs. 23.8%) and ≥1 inappropriate shocks (8.4 vs. 7.8%), and all-cause mortality (12.4 vs. 13.2%) were similar in both groups. In this large registry of ICD implanted for primary prevention, DC-ICDs were associated with higher rates of peri-implant complications and generator replacements, whereas the survival and rates of inappropriate shocks were similar in both groups. NCT#01992458. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.
Naltrexone for impulse control disorders in Parkinson disease
Papay, Kimberly; Xie, Sharon X.; Stern, Matthew; Hurtig, Howard; Siderowf, Andrew; Duda, John E.; Minger, James
2014-01-01
Objective: Impulse control disorders (ICDs) in Parkinson disease (PD) are common and can be difficult to manage. The objective of this study was to determine the efficacy and tolerability of naltrexone, an opioid antagonist, for the treatment of ICDs in PD. Methods: Patients with PD (n = 50) and an ICD were enrolled in an 8-week, randomized (1:1), double-blind, placebo-controlled study of naltrexone 50–100 mg/d (flexible dosing). The primary outcome measure was response based on the Clinical Global Impression–Change score, and the secondary outcome measure was change in symptom severity using the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease–Rating Scale (QUIP-RS) ICD score. Results: Forty-five patients (90%) completed the study. The Clinical Global Impression–Change response rate difference favoring naltrexone in completers was 19.8% (95% confidence interval [CI] −8.7% to 44.2%). While this difference was not significant (odds ratio = 1.6, 95% CI 0.5–5.2, Wald χ2 [df] = 0.5 [1], p = 0.5), naltrexone treatment led to a significantly greater decrease in QUIP-RS ICD score over time compared with placebo (regression coefficient for interaction term in linear mixed-effects model = −7.37, F[df] = 4.3 [1, 49], p = 0.04). The estimated changes in QUIP-RS ICD scores from baseline to week 8 were 14.9 points (95% CI 9.9–19.9) for naltrexone and 7.5 points (95% CI 2.5–12.6) for placebo. Conclusions: Naltrexone treatment was not efficacious for the treatment of ICDs in PD using a global assessment of response, but findings using a PD-specific ICD rating scale support further evaluation of opioid antagonists for the treatment of ICD symptoms in PD. Classification of evidence: This study provides Class I evidence that in patients with PD and an ICD, naltrexone does not significantly increase the probability of achieving response. However, the study lacked the precision to exclude an important difference in response rates. PMID:25037206
Hess, Paul L; Hernandez, Adrian F; Bhatt, Deepak L; Hellkamp, Anne S; Yancy, Clyde W; Schwamm, Lee H; Peterson, Eric D; Schulte, Phillip J; Fonarow, Gregg C; Al-Khatib, Sana M
2016-08-16
Previous studies have found that women and black patients eligible for a primary prevention implantable cardioverter-defibrillator (ICD) are less likely than men or white patients to receive one. We performed an observational analysis of the Get With The Guidelines-Heart Failure Program from January 1, 2011, to March 21, 2014. Patients admitted with heart failure and an ejection fraction ≤35% without an ICD were included. Rates of ICD counseling among eligible patients and ICD receipt among counseled patients were examined by sex and race/ethnicity. Among 21 059 patients from 236 sites, 4755 (22.6%) received predischarge ICD counseling. Women were counseled less frequently than men (19.3% versus 24.6%, P<0.001, adjusted odds ratio [OR], 0.84; 95% confidence interval [CI], 0.78-0.91). Racial and ethnic minorities were less likely to receive counseling than white patients (black 22.6%, Hispanic 18.6%, other race/ethnic group 14.4% versus white 24.3%, P<0.001 for each): adjusted OR versus white, 0.69; 95% CI, 0.63 to 0.76 for black patients; adjusted OR, 0.62; 95% CI, 0.55 to 0.70 for Hispanic patients; adjusted OR, 0.53; 95% CI, 0.43 to 0.65 for other patients. Among the 4755 counseled patients, 2977 (62.6%) received an ICD or had one planned for placement after hospital stay. Among those counseled, women and men were similarly likely to receive an ICD (adjusted OR, 1.13; 95% CI, 0.99-1.29). However, black (adjusted OR, 0.70; 95% CI, 0.56-0.88) and Hispanic patients (adjusted OR, 0.68; 95% CI, 0.46-1.01) were less likely to receive an ICD. Up to 4 of 5 hospitalized patients with heart failure eligible for ICD counseling did not receive it, particularly women and minority patients. Among counseled patients, ICD use differences by race and ethnicity persisted. © 2016 American Heart Association, Inc.
Tremblay-McLean, Alexandra; Bruneau, Julie; Lebouché, Bertrand; Lisovsky, Irene; Song, Rujun; Bernard, Nicole F
2017-10-12
Natural Killer (NK) cell responses to HIV-infected CD4 T cells (iCD4) depend on the integration of signals received through inhibitory (iNKR) and activating NK receptors (aNKR). iCD4 activate NK cells to inhibit HIV replication. HIV infection-dependent changes in the human leukocyte antigen (HLA) ligands for iNKR on iCD4 are well documented. By contrast, less is known regarding the HIV infection related changes in ligands for aNKR on iCD4. We examined the aNKR ligand profiles HIV p24⁺ HIV iCD4s that maintained cell surface CD4 (iCD4⁺), did not maintain CD4 (iCD4 - ) and uninfected CD4 (unCD4) T cells for expression of unique long (UL)-16 binding proteins-1 (ULBP-1), ULBP-2/5/6, ULBP-3, major histocompatibility complex (MHC) class 1-related (MIC)-A, MIC-B, CD48, CD80, CD86, CD112, CD155, Intercellular adhesion molecule (ICAM)-1, ICAM-2, HLA-E, HLA-F, HLA-A2, HLA-C, and the ligands to NKp30, NKp44, NKp46, and killer immunoglobulin-like receptor 3DS1 (KIR3DS1) by flow cytometry on CD4 T cells from 17 HIV-1 seronegative donors activated and infected with HIV. iCD4⁺ cells had higher expression of aNKR ligands than did unCD4. However, the expression of aNKR ligands on iCD4 where CD4 was downregulated (iCD4 - ) was similar to (ULBP-1, ULBP-2/5/6, ULBP-3, MIC-A, CD48, CD80, CD86 and CD155) or significantly lower than (MIC-B, CD112 and ICAM-2) what was observed on unCD4. Thus, HIV infection can be associated with increased expression of aNKR ligands or either baseline or lower than baseline levels of aNKR ligands, concomitantly with the HIV-mediated downregulation of cell surface CD4 on infected cells.
Otang, Wilfred M; Grierson, Donald S; Afolayan, Anthony J
2014-11-18
Potentially harmful plants grow almost everywhere, hence, it is not practical to eradicate them all. However, a basic understanding of adverse cutaneous reactions and the common plants that cause each type can enable vulnerable individuals to discover the source of their dermatitis and thus prevent re-exposure. The aim of this study therefore, was to document the plants responsible for irritant contact dermatitis (ICD) in the Eastern Cape, along with their respective irritants and clinical presentations. Study participants (161) in 12 locations were selected by convenient sampling with particular focus on local people who regularly interact with plants or plant products. Interview questions were focused on the local names of plants that contain irritating chemicals and physical characteristics that cause ICD. Forty four plant species distributed in 24 families and 34 genera were reported as causative agents of irritant contact dermatitis. Herbs constituted 67.35%, trees 24.49% and shrubs 8.16%. Mechanical ICD was reported to be caused by 23 species, closely followed by chemical ICD (20 species) and mechanico-chemical ICD (6 species). Species with the highest frequency of citations were Allium cepa, Acacia karroo, Capsicum annuum, Citrus limon and Zea mays. The most representative families were Euphorbiaceae (for chemical ICD), Urticaceae (for mechanico-chemical ICD), Fabaceae and Rutaceae for mechanical ICD. Most of the classes of chemical compounds identified as being responsible for chemical ICD were restricted to plants of specific genera such as the diterpenes in Euphorbia spp., disulphides in Allium spp., terpenes in Citrus spp. and isothiocyanates in Brassica spp. Thorns and hairs were reported for causing Mechanical ICD in 6 plant species each, including widely cultivated plants such as Acacia karoo and Citrus reticulata. Irritant contact dermatitis is a common cutaneous disorder in individuals exposed to plants in the Eastern Cape, especially among workers of the food and flower industries. Health practitioners should therefore consider the possible work-related causes of dermatitis, especially in cases associated with a clear history of symptoms. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Hyland, Philip; Brewin, Chris R; Maercker, Andreas
2017-04-01
The 11 th edition of the International Classification of Diseases (ICD-11; World Health Organization, 2017) proposes a model of posttraumatic stress disorder (PTSD) that includes 6 symptoms. This study assessed the ability of a classification-independent measure of posttraumatic stress symptoms, the Impact of Event Scale-Revised (Weiss & Marmar, 1996), to capture the ICD-11 model of PTSD. The current study also provided the first assessment of the predictive validity of ICD-11 PTSD. Former East German political prisoners were assessed in 1994 (N = 144) and in 2008-2009 (N = 88) on numerous psychological variables using self-report measures. Of the participants, 48.2% and 36.8% met probable diagnosis for ICD-11 PTSD at the first and second assessments, respectively. Confirmatory factor analysis supported the factorial validity of the 3-factor ICD-11 model of PTSD, as represented by items selected from the Impact of Event Scale-Revised. Hierarchical multiple regression analysis demonstrated that, controlling for sex, the symptom clusters of ICD-11 PTSD (reexperiencing, avoidance, and sense of threat) significantly contributed to the explanation of depression (R 2 = .17), quality of life (R 2 = .21), internalized anger (R 2 = .10), externalized anger (R 2 = .12), hatred of perpetrators (R 2 = .15), dysfunctional disclosure (R 2 = .27), and social acknowledgment as a victim (R 2 = .12) across the 15-year study period. Current findings add support for the factorial and predictive validity of ICD-11 PTSD within a unique cohort of political prisoners. Copyright © 2017 International Society for Traumatic Stress Studies.
Linder, Jarrett; Hidayatallah, Nadia; Stolerman, Marina; McDonald, Thomas V.; Marion, Robert; Walsh, Christine; Dolan, Siobhan
2014-01-01
Objective To identify major concerns associated with implantable cardioverter-defibrillators (ICDs) and to provide recommendations to adult and pediatric physicians involved in the care of patients with ICDs. Background Cardiac ion channelopathies are a well-recognized cause of sudden cardiac death in infants, children, adolescents, and young adults. ICDs are effective in preventing sudden death from fatal arrhythmias in patients with known cardiac channelopathies. There is a paucity of research on the effect of ICDs on quality of life in patients with cardiac channelopathy diagnoses, especially young patients. Methods A qualitative study interviewing patients and families affected by inherited arrhythmias was conducted. Fifty participants with personal or family histories of cardiac events or sudden death were interviewed individually or in focus groups by clinical psychologists. All interviews were transcribed verbatim and then analyzed and coded based on current qualitative research theory to identify themes related to the research question. Twenty-four participants discussed ICDs in their interviews. Results Participants reported concerns about ICDs, and these concerns were categorized into six themes: (1) comprehension and physician-patient communication; (2) anxiety; (3) restrictions and fallacies; (4) complications; (5) utility; and (6) alternative therapy. Participants noted communication breakdowns between providers and their colleagues, and between providers and their patients. Participants and their families experienced many different forms of anxiety, including worry about the aesthetics of the ICDs and fears of being shocked. Multiple restrictions, fallacies, and complications were also cited. Conclusion Interview themes were used to formulate recommendations for counseling and educating patients with ICDs. PMID:25383067
Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.
Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal
2016-01-01
The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.
Safety and interaction of patients with implantable cardiac defibrillators driving a hybrid vehicle.
Tondato, Fernando; Bazzell, Jane; Schwartz, Linda; Mc Donald, Bruce W; Fisher, Robert; Anderson, S Shawn; Galindo, Arcenio; Dueck, Amylou C; Scott, Luis R
2017-01-15
Electromagnetic interference (EMI) can affect the function of implantable cardioverter defibrillators (ICD). Hybrid electric vehicles (HEV) have increased popularity and are a potential source of EMI. Little is known about the in vivo effects of EMI generated by HEV on ICD. This study evaluated the in vivo interaction between EMI generated by HEV with ICD. Thirty patients (73±9 y/o; 80% male) with stable ICD function were exposed to EMI generated by a Toyota Prius Hybrid®. The vehicle was lifted above the ground, allowing safe changes in engine rotation and consequent variations in electromagnetic emission. EMI was measured (NARDA STS® model EHP-50C) and expressed in A/m (magnetic), Volts/m (electrical), and Hertz (frequency). Six positions were evaluated: driver, front passenger, right and left back seats, outside, at the back and front of the car. Each position was evaluated at idle, 30 mph, 60 mph and variable speeds (acceleration-deceleration-brake). All ICD devices were continuously monitored during the study. The levels of EMI generated were low (highest mean levels: 2.09A/m at right back seat at 30 mph; and 3.5V/m at driver seat at variable speeds). No episode of oversensing or inadvertent change in ICD programming was observed. It is safe for patients with ICD to interact with HEV. This is the first study to address this issue using an in vivo model. Further studies are necessary to evaluate the interaction of different models of HEV or electric engine with ICD or unipolar pacemakers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Defibrillator patients should not be denied a peaceful death.
Westerdahl, Annika Kinch; Sutton, Richard; Frykman, Viveka
2015-03-01
Implantable defibrillators (ICDs) prevent sudden cardiac death. With declining health, ICD therapy may prolong death and expose the patient to unnecessary pain and anxiety. Few studies have addressed end of life care in ICD patients. The objective of this study was to investigate end of life in ICD patients, with respect to location of death; duration between do-not-resuscitate (DNR)-orders and deactivation of ICD therapy or DNR and time of death. A descriptive analysis of 65 deceased ICD patients, all whom had a written DNR-order before death, is presented. The majority (86%) was treated in hospitals, mainly (63%) university hospitals, and many (33%) in cardiology wards. Despite DNR-order, ICD shock therapy was active in 51% of all patients. In those with therapy deactivated at death, therapy deactivation was carried out two days or more after DNR-order in more than a third (38%). The time from DNR decision to death in patients with therapy active had a median of four days (IQR 1-38). During the last 24h of life, 24% of the patients experienced shock treatment. The majority of ICD patients with a DNR-order were treated in university hospitals. More than half still had shock treatment active at time of death with a median of four days or more between DNR decision and death. Patients with therapy deactivated, two days or more elapsed in more than a third from DNR decision to deactivation of therapy, exposing patients to a high risk of painful shocks before death. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Mental and behavioural disorders in the ICD-11: concepts, methodologies, and current status.
Gaebel, Wolfgang; Zielasek, Jürgen; Reed, Geoffrey M
2017-04-30
This review provides an overview of the concepts, methods and current status of the development of the Eleventh Revision of the Mental and Behavioural Disorders chapter of the International Classification of Diseases and Related Health Problems (ICD-11) by the World Health Organization (WHO). Given the global use of the current version (ICD-10) for a wide range of applications in clinical practice and health statistics, a major aim of the development process for ICD-11 has been to increase the utility of the classification system. Expert working groups with responsibility for specific disorder groupings first suggested a set of revised diagnostic guidelines. Then surveys were performed to obtain suggestions for revisions from practicing health professionals. A completely revised structure for the classification of mental and behavioural disorders was developed and major revisions were suggested, for example, for schizophrenia and other primary psychotic disorders, substance use disorders, affective disorders and personality disorders. A new category of "gaming disorder" has been proposed and conditions related to sexual health and gender identity will be classified separately from mental disorders. An ICD-11 beta draft is freely available on the internet and public comments are invited. Field studies of the revised diagnostic guidelines are in process to obtain additional information about necessary improvements. A tabulated crosswalk from previous ICD-10 to then ICD-11 criteria will be necessary to ascertain the continuity of diagnoses for epidemiological and other statistical purposes. The final version of ICD-11 is currently scheduled for release by the World Health Assembly in 2018.
NASA Astrophysics Data System (ADS)
Offutt, Sarah J.; Ryan, Kellie J.; Konop, Alexander E.; Lim, Hubert H.
2014-12-01
Objective. The inferior colliculus (IC) is the primary processing center of auditory information in the midbrain and is one site of tinnitus-related activity. One potential option for suppressing the tinnitus percept is through deep brain stimulation via the auditory midbrain implant (AMI), which is designed for hearing restoration and is already being implanted in deaf patients who also have tinnitus. However, to assess the feasibility of AMI stimulation for tinnitus treatment we first need to characterize the functional connectivity within the IC. Previous studies have suggested modulatory projections from the dorsal cortex of the IC (ICD) to the central nucleus of the IC (ICC), though the functional properties of these projections need to be determined. Approach. In this study, we investigated the effects of electrical stimulation of the ICD on acoustic-driven activity within the ICC in ketamine-anesthetized guinea pigs. Main Results. We observed ICD stimulation induces both suppressive and facilitatory changes across ICC that can occur immediately during stimulation and remain after stimulation. Additionally, ICD stimulation paired with broadband noise stimulation at a specific delay can induce greater suppressive than facilitatory effects, especially when stimulating in more rostral and medial ICD locations. Significance. These findings demonstrate that ICD stimulation can induce specific types of plastic changes in ICC activity, which may be relevant for treating tinnitus. By using the AMI with electrode sites positioned with the ICD and the ICC, the modulatory effects of ICD stimulation can be tested directly in tinnitus patients.
Identification of ICD Codes Suggestive of Child Maltreatment
ERIC Educational Resources Information Center
Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.
2011-01-01
Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
... an Interface Control Working Group (ICWG) Meeting for Document ICD-GPS-870 AGENCY: Interface Control Working Group (ICWG) meeting for document ICD-GPS-870. ACTION: Meeting Notice. SUMMARY: This notice... Working Group (ICWG) meeting for document ICD-GPS-870, Navstar Next Generation GPS Operational Control...
Three Diagnostic Systems for Autism: DSM-III, DSM-III-R, and ICD-10.
ERIC Educational Resources Information Center
Volkmar, Fred R.; And Others
1992-01-01
This paper compared clinicians' diagnosis and DSM-III (Diagnostic and Statistical Manual), DSM-III-R (Revised), and ICD-10 (International Classification of Diseases) diagnoses of 52 individuals with autism and 62 nonautistic, developmentally disordered individuals. The DSM-III-R system overdiagnosed the presence of autism, and ICD-10 closely…
Gender incongruence of childhood in the ICD-11: controversies, proposal, and rationale.
Drescher, Jack; Cohen-Kettenis, Peggy T; Reed, Geoffrey M
2016-03-01
As part of the development of the eleventh revision of the International Classification of Diseases (ICD-11), WHO appointed a Working Group on Sexual Disorders and Sexual Health to recommend changes necessary in the classification of mental and behavioural disorders in ICD-10 that are related to sexuality and gender identity. This Personal View focuses on the Working Group's proposals to include the diagnosis gender incongruence of childhood in ICD-11 and to move gender incongruence of childhood out of the mental and behavioural disorders chapter of ICD-11. We outline the history of ICD and DSM child gender diagnoses, expert consensus, knowledge gaps, and controversies related to the diagnosis and treatment of extremely gender-variant children. We argue that retaining the gender incongruence of childhood category is justified as a basis to structure clinical care and to ensure access to appropriate services for this vulnerable population, which provides opportunities for education and informed consent, the development of standards and pathways of care to help guide clinicians and family members, and a basis for future research efforts. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tanno, Luciana Kase; Calderon, Moises A; Papadopoulos, Nikolaos G; Sanchez-Borges, Mario; Rosenwasser, Lanny J; Bousquet, Jean; Pawankar, Ruby; Sisul, Juan Carlos; Cepeda, Alfonso Mario; Li, James; Muraro, Antonella; Fineman, Stanley; Sublett, James L; Katelaris, Constance H; Chang, Yoon-Seok; Moon, Hee-Bom; Casale, Thomas; Demoly, Pascal
2016-01-01
Allergy and hypersensitivity intervention management procedures, such as desensitization and/or tolerance induction and immunotherapy, have not been pondered up to now in the content of International Classification of Diseases (ICD) context because the focus has been on prioritizing the condition implementations. Tremendous efforts have been devoted to implementing allergic and hypersensitivity conditions in the forthcoming ICD-11. However, we consider that it is crucial now to have nomenclature and classification universally accepted for these procedures to be able to provide scientifically consistent proposals into the new ICD-11 platform for the best practice parameters of our specialty. With the aim of promoting a harmonized comprehension and aligning it with the ICD-11 revision, we have reviewed the definitions and concepts currently used for desensitization and/or tolerance induction and immunotherapy. We strongly believe that this review is a key instrument to support the allergy specialty identity into the ICD-11 framework and serves as a platform to perform positive quality improvement in clinical practice. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.
DeJong, Sandra; Arnett, Justin K.; Kennedy, Kathleen; Franklin, Jay O.; Berbarie, Rafic F.
2014-01-01
Firefighters who have received an implantable cardioverter-defibrillator (ICD) are asked to retire or are permanently placed on restricted duty because of concerns about their being incapacitated by an ICD shock during a fire emergency. We present the case of a 40-year-old firefighter who, after surviving sudden cardiac arrest and undergoing ICD implantation, sought to demonstrate his fitness for active duty by completing a high-intensity, occupation-specific cardiac rehabilitation training program. The report details the exercise training, ICD monitoring, and stress testing that he underwent. During the post-training treadmill stress test in firefighter turnout gear, the patient reached a functional capacity of 17 metabolic equivalents (METs), exceeding the 12-MET level required for his occupation. He had no ICD shock therapy or recurrent sustained arrhythmias during stress testing or at any time during his cardiac rehabilitation stay. By presenting this case, we hope to stimulate further discussion about firefighters who have an ICD, can meet the functional capacity requirements of their occupation, and want to return to work. PMID:24982569
Adams, Jenny; DeJong, Sandra; Arnett, Justin K; Kennedy, Kathleen; Franklin, Jay O; Berbarie, Rafic F
2014-07-01
Firefighters who have received an implantable cardioverter-defibrillator (ICD) are asked to retire or are permanently placed on restricted duty because of concerns about their being incapacitated by an ICD shock during a fire emergency. We present the case of a 40-year-old firefighter who, after surviving sudden cardiac arrest and undergoing ICD implantation, sought to demonstrate his fitness for active duty by completing a high-intensity, occupation-specific cardiac rehabilitation training program. The report details the exercise training, ICD monitoring, and stress testing that he underwent. During the post-training treadmill stress test in firefighter turnout gear, the patient reached a functional capacity of 17 metabolic equivalents (METs), exceeding the 12-MET level required for his occupation. He had no ICD shock therapy or recurrent sustained arrhythmias during stress testing or at any time during his cardiac rehabilitation stay. By presenting this case, we hope to stimulate further discussion about firefighters who have an ICD, can meet the functional capacity requirements of their occupation, and want to return to work.
Expression of Active Notch1 in Avian Coronary Development
Yang, Ke; Doughman, Yong-Qiu; Karunamuni, Ganga; Gu, Shi; Yang, Yu-Chung; Bader, David M.; Watanabe, Michiko
2010-01-01
Notch1 is an important regulator of intercellular interactions in cardiovascular development. We show that the nuclear-localized, cleaved and active form of Notch1, the Notch1 intracellular domain (N1ICD), appeared in mesothelial cells of the pro-epicardium during epicardial formation at looped heart stages. N1ICD was also present in mesothelial cells and mesenchymal cells specifically within the epicardium at sulcus regions. N1ICD-positive endothelial cells were detected within the nascent vessel plexus at the atrio-ventricular junction and within the compact myocardium (HH25-30). The endothelial cells expressing N1ICD were surrounded by N1ICD positive smooth muscle cells after coronary orifice formation (HH32-35), while N1ICD expression was absent in the mesenchymal and mesothelial cells surrounding mature coronary vessels. We propose that differential activation of the hypoxia/HIF1-VEGF-Notch pathway may play a role in epicardial cell interactions that promote epicardial EMT and coronary progenitor cell differentiation during epicardial development and coronary vasculogenesis in particularly hypoxic sulcus regions. PMID:19097050
Bugalho, Paulo; Oliveira-Maia, Albino J
2013-01-01
Non-motor symptoms contribute significantly to Parkinson's disease (PD) related disability. Impulse control disorders (ICDs) have been recently added to the behavioural spectrum of PD-related non-motor symptoms. Such behaviours are characterized by an inappropriate drive to conduct repetitive behaviours that are usually socially inadequate or result in harmful consequences. Parkinson disease impulse control disorders (PD-ICDs) have raised significant interest in the scientific and medical community, not only because of their incapacitating nature, but also because they may represent a valid model of ICDs beyond PD and a means to study the physiology of drive, impulse control and compulsive actions in the normal brain. In this review, we discuss some unresolved issues regarding PD-ICDs, including the association with psychiatric co-morbidities such as obsessive-compulsive disorder and with dopamine related side effects, such as hallucinations and dyskinesias; the relationship with executive cognitive dysfunction; and the neural underpinnings of ICDs in PD. We also discuss the contribution of neuroscience studies based on animal-models towards a mechanistic explanation of the development of PD-ICDs, specifically regarding corticostriatal control of goal directed and habitual actions.
Harmonisation of ICD-11 and DSM-V: opportunities and challenges.
First, Michael B
2009-11-01
Differences in the ICD-10 and DSM-IV definitions for the same disorder impede international communication and research efforts. The forthcoming parallel development of DSM-V and ICD-11 offers an opportunity to harmonise the two classifications. This paper aims to facilitate the harmonisation process by identifying diagnostic differences between the two systems. DSM-IV-TR criteria sets and the ICD-10 Diagnostic Criteria for Research were compared and categorised into those with identical definitions, those with conceptually based differences and those in which differences are not conceptually based and appear to be unintentional. Of the 176 criteria sets in both systems, only one, transient tic disorder, is identical. Twenty-one per cent had conceptually based differences and 78% had non-conceptually based differences. Harmonisation of criteria sets, especially those with non-conceptually based differences, should be prioritised in the DSM-V and ICD-11 development process. Prior experience with the DSM-IV and ICD-10 harmonisation effort suggests that for the process to be successful steps should be taken as early as possible.
Ohlow, Marc-Alexander; Roos, Marcus; Lauer, Bernward; Von Korn, Hubertus; Geller, Johann Christoph
2016-07-01
Inadvertent lead malposition (ILM) in the left heart is a potential cause of thromboembolism and, therefore, a complication of heart rhythm device implantation [HRDI: pacemaker, implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy (CRT)]. The aim of the study was to report the incidence and clinical outcome of ILM. Postoperative lateral and posterior-anterior chest X-rays of all consecutive patients undergoing HRDI from 2007 through 2012 were retrospectively analysed. During the study period, 2579 patients underwent HRDI at our institution. ILM was present in six patients (0.34%, 50% male, mean age 71.5 ± 9.4 years). In one and four patients, malposition was in the left atrium and ventricle, respectively. In one case, the RV-lead was placed in a coronary sinus branch. In four patients, ILM was detected intra-operatively or in the early postoperative period. In the remaining two patients, malposition was not recognized and they suffered cerebral embolism 4 months and 1 year after implantation. ILM was corrected during the same hospital stay (four cases), or during follow-up by percutaneous extraction (two cases). Patients with ILM had significantly more scoliosis (16.7 vs. 0.17%; P = 0.01), congenital heart disease (CHD: 33.3 vs. 0.4%; P = 0.003), or prior surgery for CHD (16.7 vs. 0.5%; P = 0.03). The likelihood of ILM was also increased when HRDI was performed by an inexperienced operator (<100 HRDI; P < 0.01). The incidence of ILM was 0.34% in our series. Scoliosis, CHD, prior correction of CHD, and limited operator experience were identified as risk factors. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Cytokines in immunogenic cell death: Applications for cancer immunotherapy.
Showalter, Anne; Limaye, Arati; Oyer, Jeremiah L; Igarashi, Robert; Kittipatarin, Christina; Copik, Alicja J; Khaled, Annette R
2017-09-01
Despite advances in treatments like chemotherapy and radiotherapy, metastatic cancer remains a leading cause of death for cancer patients. While many chemotherapeutic agents can efficiently eliminate cancer cells, long-term protection against cancer is not achieved and many patients experience cancer recurrence. Mobilizing and stimulating the immune system against tumor cells is one of the most effective ways to protect against cancers that recur and/or metastasize. Activated tumor specific cytotoxic T lymphocytes (CTLs) can seek out and destroy metastatic tumor cells and reduce tumor lesions. Natural Killer (NK) cells are a front-line defense against drug-resistant tumors and can provide tumoricidal activity to enhance tumor immune surveillance. Cytokines like IFN-γ or TNF play a crucial role in creating an immunogenic microenvironment and therefore are key players in the fight against metastatic cancer. To this end, a group of anthracyclines or treatments like photodynamic therapy (PDT) exert their effects on cancer cells in a manner that activates the immune system. This process, known as immunogenic cell death (ICD), is characterized by the release of membrane-bound and soluble factors that boost the function of immune cells. This review will explore different types of ICD inducers, some in clinical trials, to demonstrate that optimizing the cytokine response brought about by treatments with ICD-inducing agents is central to promoting anti-cancer immunity that provides long-lasting protection against disease recurrence and metastasis. Copyright © 2017. Published by Elsevier Ltd.
Electrical storm in patients with an implanted defibrillator: a matter of definition.
Israel, Carsten W; Barold, S Serge
2007-10-01
The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter defibrillator (ICD), ES is best defined as 3 appropriate VT detections in 24 h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. The number of shocks and inappropriate detections are irrelevant for the definition. ES occurs in approximately 25% of ICD patients within 3 years, with typically 5-55 individual VTs within one storm. Potential triggers can be found in approximately 66% of patients and include new/worsened heart failure, changes in antiarrhythmic medication, context with other illness, psychological stress, diarrhea, and hypokalemia. In most patients, ES consists of monomorphic VT indicating the presence of reentry while ventricular fibrillation indicating acute ischemia is rare. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Long-term prognostic implications of ES are unclear. The key intervention in ES is reduction of the elevated sympathetic tone by beta blockers and frequently benzodiazepines. Amiodarone i.v. has also been successful and azimilide seems promising while class I antiarrhythmic drugs are usually unsuccessful. Substrate mapping and VT ablation may be useful in treatment and prevention of ES. Prevention of ES requires ICD programming systematically avoiding unnecessary shocks (long VT detection, antitachycardia pacing where ever possible) which otherwise can fuel the sympathetic tone and prolong ES.
Torres, Jose Luis; Shah, Bindi K; Greenberg, Richard M; Deger, Florin Titus; Gerstenfeld, Edward P
2010-10-01
We hypothesized that in patients with left ventricular dysfunction undergoing implant of a biventricular ICD, the local dominant frequency during early induced ventricular fibrillation would be higher at an epicardial left ventricular position compared to an endocardial right ventricular position. Patients undergoing implant of a biventricular ICD were studied. During ventricular fibrillation induction, bipolar electrograms were recorded from leads at an epicardial left ventricular position and an endocardial right ventricular position. Overlapping 2-s fast Fourier transforms were obtained for 6 s of ventricular fibrillation. The dominant frequency and organizational index were compared. Thirty-four patients (20 men, age 64 ± 11 years) underwent 57 inductions of ventricular fibrillation. Eighteen patients had non-ischemic dilated cardiomyopathy and 16 had ischemic dilated cardiomyopathy. The dominant frequency was higher at a lateral epicardial left ventricular position than an apical endocardial right ventricular position in 18 patients with non-ischemic dilated cardiomyopathy (LV epicardial 5.34 ± 0.37 Hz, RV endocardial 5.09 ± 0.41 Hz, p < 0.001), but not in 16 patients with ischemic dilated cardiomyopathy (LV epicardial 4.99 ± 0.57 Hz, RV epicardial 4.87 ± 0.65 Hz, p = 0.094). In patients with non-ischemic dilated cardiomyopathy, there is a dominant frequency gradient during early ventricular fibrillation induced at ICD testing from the lateral left ventricular epicardium to the apical right ventricular endocardium.
Implanted near-infrared spectroscopy for cardiac monitoring
NASA Astrophysics Data System (ADS)
Bhunia, Sourav K.; Cinbis, Can
2011-02-01
Implanted Cardioverter Defibrillator (ICD) provides one of the most effective therapies for the prevention of sudden cardiac death, but also delivers some high voltage shocks inappropriately, causing morbidity and mortality. Implanted near-infrared spectroscopy (NIRS) may augment ICD arrhythmia detection by monitoring skeletal muscle perfusion. A two-wavelength, single-distance, continuous-wave implanted NIRS has been evaluated in-vivo. A weighted difference of the changes in attenuation at two wavelengths, across the isobestic point of the hemoglobin spectra, was taken to be the microvascular oxygenation trend indicator (O2 Index). Although the exact weight depends on the local vascular distribution and their oxygen levels, the hypothesis that a constant weight may be adequate for hemodynamic trending during short arrhythmic episodes, was tested. The sensor was implanted subcutaneously both on fresh tissue and inside scar tissue that formed around a pre-existing implant, in 3 animals each. Attenuations were recorded at 660 and 890 nm during normal sinus rhythm (NSR) and induced ventricular fibrillation (VF). The slope of the O2 Index over 10 seconds was computed for 7 NSR and 8 VF episodes in fresh and 13 NSR and 15 VF episodes in scar tissue pockets. The mean O2 Index slope was significantly different (p<0.0001) between NSR and VF rhythms for both the fresh and scar tissue pockets. Therefore implanted NIRS may be useful for preventing inappropriate detection of VF during electromagnetic interference, double counting of ECG T-wave as an R-wave, ICD lead failure, electrocardiographic aberrancy etc.
Leroi, Iracema; Barraclough, Michelle; McKie, Shane; Hinvest, Neal; Evans, Jonathan; Elliott, Rebecca; McDonald, Kathryn
2013-09-01
The development of impulse control disorders (ICDs) in Parkinson's disease (PD) may arise from an interaction among cognitive impairment, impulsive responding and dopaminergic state. Dopaminergic state may be influenced by pharmacologic or genotypic (catechol-O-methyltransferase; COMT) factors. We sought to investigate this interaction further by comparing those with (n = 35) and without (n = 55) ICDs on delay-discounting in different pharmacologic conditions (ON or OFF dopaminergic medication) and on response inhibition as well as aspects of executive functioning in the ON state. We then undertook an exploratory sub-group analysis of these same tasks when the overall PD group was divided into different allelic variants of COMT (val/val vs. met/met). A healthy control group (HC; n = 20) was also included. We found that in those with PD and ICDs, 'cognitive flexibility' (set shifting, verbal fluency, and attention) in the ON medication state was not impaired compared with those without ICDs. In contrast, our working memory, or 'cognitive focus', task was impaired in both PD groups compared with the HC group when ON. During the delay-discounting task, the PD with ICDs group expressed greater impulsive choice compared with the PD group without ICDs, when in the ON, but not the OFF, medication state. However, no group difference on the response inhibition task was seen when ON. Finally, the met homozygous group performed differently on tests of executive function compared with the val homozygous group. We concluded that the disparity in levels of impairment among different domains of executive function and impulsive decision-making distinguishes those with ICD in PD from those without ICD, and may in part be affected by dopaminergic status. Both pharmacologic and genotypic influences on dopaminergic state may be important in ICD. © 2013 The British Psychological Society.
Knops, Paul; Theuns, Dominic A M J; Res, Jan C J; Jordaens, Luc
2009-10-01
Information about implantable cardioverter-defibrillator (ICD) longevity is mostly calculated from measurements under ideal laboratory conditions. However, little information about longevity under clinical circumstances is available. This survey gives an overview on ICD service times and generator replacements in a cohort of consecutive ICD patients. Indications for replacement were classified as a normal end-of-service (EOS), premature EOS, system malfunction, infection and device advisory, or recall actions. From the premature and normal EOS group, longevity from single-chamber (SC), dual-chamber (DC), and cardiac resynchronization therapy defibrillator (CRT-D), rate-responsive (RR) settings, high output (HO) stimulation, and indication for ICD therapy was compared. Differences between brands were compared as well. In a total of 854 patients, 203 ICD replacements (165 patients) were recorded. Premature and normal EOS replacements consisted of 32 SC, 98 DC and 24 CRT-D systems. Longevity was significantly longer in SC systems compared to DC and CRT-D systems (54 +/- 19 vs. 40 +/- 17 and 42 +/- 15 months; P = 0.008). Longevity between non-RR (n = 143) and RR (n = 11) settings was not significantly different (43 +/- 18 vs. 45 +/- 13 months) as it also was not for HO versus non-HO stimulation (43 +/- 19 vs. 46 +/- 17 months). Longevity of ICDs was not significantly different between primary and secondary prevention (42 +/- 19 vs. 44 +/- 18 months). The average longevity on account of a device-based EOS message was 43 +/- 18 months. Average longevity for Biotronik (BIO, n = 72) was 33 +/- 10 months, for ELA Medical (ELA, n = 12) 44 +/- 17 months, for Guidant (GDT, n = 36) 49 +/- 12 months, for Medtronic (MDT, n = 29) 62 +/- 22 months, and for St. Jude Medical (SJM, n = 5) 31 +/- 9 months (P < 0.001). SC ICD generators had a longer service time compared to DC and CRT-D systems. No influence of indication for ICD therapy and HO stimulation on generator longevity was observed in this study. MDT ICDs had the longest service time.
Identifying Vasopressor and Inotrope Use for Health Services Research
Fawzy, Ashraf; Bradford, Mark; Lindenauer, Peter K.
2016-01-01
Rationale: Identifying vasopressor and inotrope (vasopressor) use from administrative claims data may provide an important resource to study the epidemiology of shock. Objectives: Determine accuracy of identifying vasopressor use using International Classification of Disease, Ninth Revision, Clinical Modification (ICD-9-CM) coding. Methods: Using administrative data enriched with pharmacy billing files (Premier, Inc., Charlotte, NC), we identified two cohorts: adult patients admitted with a diagnosis of sepsis from 2010 to 2013 or pulmonary embolism (PE) from 2008 to 2011. Vasopressor administration was obtained using pharmacy billing files (dopamine, dobutamine, epinephrine, milrinone, norepinephrine, phenylephrine, vasopressin) and compared with ICD-9-CM procedure code for vasopressor administration (00.17). We estimated performance characteristics of the ICD-9-CM code and compared patients’ characteristics and mortality rates according to vasopressor identification method. Measurements and Main Results: Using either pharmacy data or the ICD-9-CM procedure code, 29% of 541,144 patients in the sepsis cohort and 5% of 81,588 patients in the PE cohort were identified as receiving a vasopressor. In the sepsis cohort, the ICD-9-CM procedure code had low sensitivity (9.4%; 95% confidence interval, 9.2–9.5), which increased over time. Results were similar in the PE cohort (sensitivity, 5.8%; 95% confidence interval, 5.1–6.6). The ICD-9-CM code exhibited high specificity in the sepsis (99.8%) and PE (100%) cohorts. However, patients identified as receiving vasopressors by ICD-9-CM code had significantly higher unadjusted in-hospital mortality, had more acute organ failures, and were more likely hospitalized in the Northeast and West. Conclusions: The ICD-9-CM procedure code for vasopressor administration has low sensitivity and selects for higher severity of illness in studies of shock. Temporal changes in sensitivity would likely make longitudinal shock surveillance using ICD-9-CM inaccurate. PMID:26653145
Kumar, Sunil; Agarwal, Nitin; Rattan, Amulya; Rathi, Vinita
2014-01-01
Context: Thoracic trauma causes significant morbidity; however, many deaths are preventable and few patients require surgery. Intercostal chest drainage (ICD) for hemo/pneumothorax is simple and effective; the main problem is residual hemothorax, which can cause lung collapse and empyema. Aims: Our study aimed to analyze the relationship between radiological chest tube parameters (position and intrathoracic length) and the frequency of residual hemothorax. Settings and Design: This prospective analytical study was conducted in a large tertiary care hospital in north India over 2 years till March 2013. Materials and Methods: Patients of chest trauma aged 18-60 years, with hemothorax or hemopneumothorax requiring ICD insertion were included in the study. Bedside ICD insertion was performed as per current standards. Immediate post-ICD chest radiographs were used to record lung status and ICD position (chest tube zone and intrapleural length). Residual hemothorax was defined as any collection identified on radiological investigations after 48 hours of ICD placement. Statistical Analysis: Univariate analysis was performed with the chi-square test or Student's t-test as appropriate, while multivariate analysis using stepwise logistic regression; a P-value < 0.05 was significant. Results: Out of 170 patients of chest trauma, 154 underwent ICD insertion. Most patients were young (mean age: 31.7 ± 12 years) males (M:F = 14:1). Ninety-seven patients (57.1%) had isolated chest injuries. Blunt trauma (n = 119; 77.3%) and motor vehicle accidents (n = 72; 46.7%) were the commonest causes. Mean hospital stay was 9 ± 3.94 days, and mortality 2/154 (1.1%). Residual hemothorax was seen in 48 (31%). No ICD zone or length was significantly associated with residual hemothorax on univariate or multivariate analysis. Conclusion: Intrapleural ICD zone or length does not affect the frequency of residual hemothorax. PMID:25400388
Bell, J J; Bauer, J D; Capra, S; Pulle, R C
2014-03-01
Differences in malnutrition diagnostic measures impact malnutrition prevalence and outcomes data in hip fracture. This study investigated the concurrent and predictive validity of commonly reported malnutrition diagnostic measures in patients admitted to a metropolitan hospital acute hip fracture unit. A prospective, consecutive level II diagnostic accuracy study (n=142; 8 exclusions) including the International Classification of Disease, 10th Revision, Australian Modification (ICD10-AM) protein-energy malnutrition criteria, a body mass index (BMI) <18.5 kg/m(2), the Mini-Nutrition Assessment Short-Form (MNA-SF), pre-operative albumin and geriatrician individualised assessment. Patients were predominantly elderly (median age 83.5, range 50-100 years), female (68%), multimorbid (median five comorbidities), with 15% 4-month mortality. Malnutrition prevalence was lowest when assessed by BMI (13%), followed by MNA-SF (27%), ICD10-AM (48%), albumin (53%) and geriatrician assessment (55%). Agreement between measures was highest between ICD10-AM and geriatrician assessment (κ=0.61) followed by ICD10-AM and MNA-SF measures (κ=0.34). ICD10-AM diagnosed malnutrition was the only measure associated with 48-h mobilisation (35.0 vs 55.3%; P=0.018). Reduced likelihood of home discharge was predicted by ICD-10-AM (20.6 vs 57.1%; P=0.001) and MNA-SF (18.8 vs 47.8%; P=0.035). Bivariate analysis demonstrated ICD10-AM (relative risk (RR)1.2; 1.05-1.42) and MNA-SF (RR1.2; 1.0-1.5) predicted 4-month mortality. When adjusted for age, usual place of residency, comorbidities and time to surgery only ICD-10AM criteria predicted mortality (odds ratio 3.59; 1.10-11.77). Albumin, BMI and geriatrician assessment demonstrated limited concurrent and predictive validity. Malnutrition prevalence in hip fracture varies substantially depending on the diagnostic measure applied. ICD-10AM criteria or the MNA-SF should be considered for the diagnosis of protein-energy malnutrition in frail, multi-morbid hip fracture inpatients.
Friedman, Daniel J; Fudim, Marat; Overton, Robert; Shaw, Linda K; Patel, Divyang; Pokorney, Sean D; Velazquez, Eric J; Al-Khatib, Sana M
2018-07-01
Left ventricular ejection fraction (LVEF) is used to select patients for primary prevention implantable cardioverter defibrillators (ICDs). The relationship between baseline and long-term follow-up LVEF and clinical outcomes among primary prevention ICD patients remains unclear. We studied 195 patients with a baseline LVEF ≤35% ≤6 months prior to ICD implantation and follow-up LVEF 1-3 years after ICD implantation without intervening left ventricular assist device (LVAD) or transplant. The co-primary study endpoints were: (1) a composite of time to death, LVAD, or transplant and (2) appropriate ICD therapy. We examined multivariable Cox proportional hazard models with a 3-year post-implant landmark view; the LVEF closest to the 3-year mark was considered the follow-up LVEF for analyses. Follow-up LVEF was examined using 2 definitions: (1) ≥10% improvement compared to baseline or (2) actual value of ≥40%. Fifty patients (26%) had a LVEF improvement of ≥10% and 44 (23%) had a follow-up LVEF ≥40%. Neither baseline nor follow-up LVEF was significantly associated with the composite endpoint. In contrast, both baseline and follow-up LVEF were associated with risk for long-term ICD therapies, whether follow-up LVEF was modeled as a ≥10% absolute improvement (baseline LVEF HR 0.87, CI 0.91-0.93, P < .001; follow-up LVEF HR 0.18, CI 0.06-0.53, P = .002) or a ≥40% follow-up value (baseline LVEF HR 0.89, CI 0.83-0.96, P = .001, follow-up LVEF HR 0.26, CI 0.08-0.87, P = .03). Among primary prevention ICD recipients, both baseline and follow-up LVEF were independently associated with long-term risk for appropriate ICD therapy, but they were not associated with time to the composite of LVAD, transplant, or death. Copyright © 2018 Elsevier Inc. All rights reserved.
Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation.
Akter, Jesmin; Takatori, Atsushi; Islam, Md Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira
2014-10-10
We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas. Copyright © 2014 Elsevier Inc. All rights reserved.
Ventricular Arrhythmias in the North American Multidisciplinary Study of ARVC
Link, Mark S.; Laidlaw, Douglas; Polonsky, Bronislava; Zareba, Wojciech; McNitt, Scott; Gear, Kathleen; Marcus, Frank; Mark Estes, NA
2015-01-01
BACKGROUND Arrhythmogenic right ventricular cardiomyopathy (ARVC) is associated with sudden cardiac death. However, the selection of patients for implanted cardioverter-defibrillators (ICDs), as well as programming of the ICD, is unclear. OBJECTIVES The objective of this study was to identify predictors, characteristics, and treatment of ventricular arrhythmias in patients with ARVC. METHODS The Multidisciplinary Study of Right Ventricular Cardiomyopathy established the North American ARVC Registry and enrolled patients with a diagnosis of ARVC. Patients were followed prospectively. RESULTS Of 137 patients enrolled, 108 received ICDs. Forty-eight patients had 502 sustained episodes of ventricular arrhythmias, including 489 that were monomorphic and 13 that were polymorphic. In the patients with ICDs, independent predictors of ventricular arrhythmias in follow-up included spontaneous sustained ventricular arrhythmias before ICD implantation and T-wave inversions inferiorly. The only independent predictor for life-threatening arrhythmias, defined as sustained ventricular tachycardia (VT) ≥240 beats/min or ventricular fibrillation, was a younger age at enrollment. Anti-tachycardia pacing (ATP), independent of the cycle length of the VT, was successful in terminating 92% of VT episodes. CONCLUSIONS In the North American ARVC Registry, the majority of ventricular arrhythmias in follow-up are monomorphic. Risk factors for ventricular arrhythmias were spontaneous ventricular arrhythmias before enrollment and a younger age at ICD implantation. ATP is highly successful in terminating VT, and all ICDs should be programmed for ATP, even for rapid VT. PMID:25011714
Jiménez-Urbieta, Haritz; Gago, Belén; de la Riva, Patricia; Delgado-Alvarado, Manuel; Marin, Concepció; Rodriguez-Oroz, María C
2015-09-01
Dopaminergic treatment in Parkinson's disease (PD) reduces the severity of motor symptoms of the disease. However, its chronic use is associated with disabling motor and behavioral side effects, among which levodopa-induced dyskinesias (LID) and impulse control disorders (ICD) are the most common. The underlying mechanisms and pathological substrate of these dopaminergic complications are not fully understood. Recently, the refinement of imaging techniques and the study of the genetics and molecular bases of LID and ICD indicate that, although different, they could share some features. In addition, animal models of parkinsonism with LID have provided important knowledge about mechanisms underlying such complications. In contrast, animal models of parkinsonism and abnormal impulsivity, although useful regarding some aspects of human ICD, do not fully resemble the clinical phenotype of ICD in patients with PD, and until now have provided limited information. Studies on animal models of addiction could complement the previous models and provide some insights into the background of these behavioral complications given that ICD are regarded as behavioral addictions. Here we review the most relevant advances in relation to imaging, genetics, biochemistry and pharmacological interventions to treat LID and ICD in patients with PD and in animal models with a view to better understand the overlapping and unique maladaptations to dopaminergic therapy that are associated with LID and ICD. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gold, Michael R; Knops, Reinoud; Burke, Martin C; Lambiase, Pier D; Russo, Andrea M; Bongiorni, Maria Grazia; Deharo, Jean-Claude; Aasbo, Johan; El Chami, Mikhael F; Husby, Michael; Carter, Nathan; Boersma, Lucas
2017-01-01
The UNTOUCHED study will assess the safety and efficacy of the subcutaneous implantable cardioverter defibrillator (S-ICD) in the most common cohort of patients receiving ICDs. The primary goal is to evaluate the inappropriate shock (IAS)-free rate in primary prevention patients with a reduced ejection fraction (EF) and compare with a historical control of transvenous ICD patients with similar programming. The UNTOUCHED study is a global, multicenter, prospective, nonrandomized study of patients undergoing de novo S-ICD implantation for primary prevention of sudden cardiac death with a left ventricular EF ≤35%. The primary end point of this trial is freedom from IAS at 18 months. The lower 95% confidence bound of the observed incidence will be compared to a performance goal of 91.6%, which was derived from the IAS rate in MADIT-RIT. The secondary end points are all-cause shock-free rate at 18 months, and system- and procedure-related complication-free rate at 1 month and 6 months. Enrollment of a minimum of 1,100 subjects from up to 200 centers worldwide is planned based on power calculations of the primary and principal secondary end points. This trial will provide important data regarding the rates of inappropriate and appropriate shock therapy in real-world use of the S-ICD in the most common group of patients receiving ICDs. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Choi, Yoonsun; He, Michael; Harachi, Tracy W.
2008-01-01
Intergenerational cultural dissonance (ICD)--a clash between parents and children over cultural values--is a frequent issue for Asian American youth. Using longitudinal data from the Cross Cultural Families Project, this study examines the mechanisms by which ICD contributes to problem behaviors, including whether ICD predicts parent-child…
ERIC Educational Resources Information Center
Shrestha, Kishor
This paper presents an overview of the Integrated Child Development Services (ICDS) program in India, discusses the context of Early Childhood Education (ECE) in Nepal, analyzes the best practices of the ICDS, and draws some policy implications for improving ECE in Nepal. The ICDS program is an integrated child development program with the…
Stocks, S J; McNamee, R; Turner, S; Carder, M; Agius, R M
2015-07-01
Reducing healthcare-associated infections (HCAI) has been a priority in the U.K. over recent decades and this has been reflected in interventions focusing on improving hygiene procedures. To evaluate whether these interventions coincided with an increased incidence of work-related irritant contact dermatitis (ICD) attributed to hand hygiene or/and other hygiene measures in healthcare workers (HCWs). A quasi-experimental (interrupted time series) design was used to compare trends in incidence of ICD in HCWs attributed to hygiene before and after interventions to reduce HCAI with trends in the same periods in control groups (ICD in other workers). Cases of ICD reported to a U.K. surveillance scheme from 1996 to 2012 were analysed. The time periods compared were defined objectively based on the dates of the publication of national evidence-based guidelines, the U.K. Health Act 2006 and the Cleanyourhands campaign. The reported incidence of ICD in HCWs attributed to hygiene has increased steadily from 1996 to 2012 [annual incidence rate ratio (95% confidence interval): hand hygiene only 1.10 (1.07-1.12); all hygiene 1.05 (1.03-1.07)], whereas the incidence in other workers is declining. An increase in incidence of ICD in HCWs attributed to hand hygiene was observed at the beginning of the Cleanyourhands campaign. The increasing incidence of ICD in HCWs combined with the popularity of interventions to reduce HCAI warrants increased efforts towards identifying products and implementing practices posing the least risk of ICD. © 2015 British Association of Dermatologists.
Infant Deaths Due To Herpes Simplex Virus, Congenital Syphilis, and HIV in New York City.
Sampath, Amitha; Maduro, Gil; Schillinger, Julia A
2016-04-01
Neonatal infection with herpes simplex virus (HSV) is not a nationally reportable disease; there have been few population-based measures of HSV-related infant mortality. We describe infant death rates due to neonatal HSV as compared with congenital syphilis (CS) and HIV, 2 reportable, perinatally transmitted diseases, in New York City from 1981 to 2013. We identified neonatal HSV-, CS-, and HIV-related deaths using International Classification of Diseases (ICD) codes listed on certificates of death or stillbirth issued in New York City. Deaths were classified as HSV-related if certificates listed (1) any HSV ICD-9/ICD-10 codes for deaths ≤42 days of age, (2) any HSV ICD-9/ICD-10 codes and an ICD code for perinatal infection for deaths at 43 to 365 days of age, or (3) an ICD-10 code for congenital HSV. CS- and HIV-related deaths were those listing any ICD code for syphilis or HIV. There were 34 deaths due to neonatal HSV (0.82 deaths per 100 000 live births), 38 from CS (0.92 per 100 000), and 262 from HIV (6.33 per 100 000). There were no CS-related deaths after 1996, and only 1 HIV-related infant death after 2004. The neonatal HSV-related death rate during the most recent decade (2004-2013) was significantly higher than in previous years. The increasing neonatal HSV-related death rate may reflect increases in neonatal herpes incidence; an increasing number of pregnant women have never had HSV type 1 and are therefore at risk of acquiring infection during pregnancy and transmitting to their infant. Copyright © 2016 by the American Academy of Pediatrics.
Hafstad, G S; Thoresen, S; Wentzel-Larsen, T; Maercker, A; Dyb, G
2017-05-01
The conceptualization of post-traumatic stress disorder (PTSD) in the upcoming International Classification of Diseases (ICD)-11 differs in many respects from the diagnostic criteria in the Diagnostic and Statistical Manual for Mental Disorders, fifth edition (DSM-5). The consequences of these differences for individuals and for estimation of prevalence rates are largely unknown. This study investigated the concordance of the two diagnostic systems in two separate samples at two separate waves. Young survivors of the 2011 Norway attacks (n = 325) and their parents (n = 451) were interviewed at 4-6 months (wave 1) and 15-18 months (wave 2) after the shooting. PTSD was assessed with the UCLA PTSD Reaction Index for DSM-IV adapted for DSM-5, and a subset was used as diagnostic criteria for ICD-11. In survivors, PTSD prevalence did not differ significantly at any time point, but in parents, the DSM-5 algorithm produced significantly higher prevalence rates than the ICD-11 criteria. The overlap was fair for survivors, but amongst parents a large proportion of individuals met the criteria for only one of the diagnostic systems. No systematic differences were found between ICD-11 and DSM-5 in predictive validity. The proposed ICD-11 criteria and the DSM-5 criteria performed equally well when identifying individuals in distress. Nevertheless, the overlap between those meeting the PTSD diagnosis for both ICD-11 and DSM-5 was disturbingly low, with the ICD-11 criteria identifying fewer people than the DSM-5. This represents a major challenge in identifying individuals suffering from PTSD worldwide, possibly resulting in overtreatment or unmet needs for trauma-specific treatment, depending on the area of the world in which patients are being diagnosed.
Sachser, Cedric; Berliner, Lucy; Holt, Tonje; Jensen, Tine; Jungbluth, Nathaniel; Risch, Elizabeth; Rosner, Rita; Goldbeck, Lutz
2018-02-01
In contrast to the DSM-5, which expanded the posttraumatic stress disorder (PTSD) symptom profile to 20 symptoms, a workgroup of the upcoming ICD-11 suggested a reduced symptom profile with six symptoms for PTSD. Therefore, the objective of the study was to investigate the dimensional structure of DSM-5 and ICD-11 PTSD in a clinical sample of trauma-exposed children and adolescents and to compare the diagnostic rates of PTSD between diagnostic systems. The study sample consisted of 475 self-reports and 424 caregiver-reports on the child and adolescent trauma screen (CATS), which were collected at pediatric mental health clinics in the US, Norway and Germany. The factor structure of the PTSD construct as defined in the DSM-5 and in alternative models of both DSM-5 and ICD-11 was investigated using confirmatory factor analyses (CFA). To evaluate differences in PTSD prevalence, McNemar's tests for correlated proportions were used. CFA results demonstrated excellent model fit for the proposed ICD-11 model of PTSD. For the DSM-5 models we found the best fit for the hybrid model. Diagnostic rates were significantly lower according to ICD-11 (self-report: 23.4%; caregiver-report: 16.5%) compared with the DSM-5 (self-report: 37.8%; caregiver-report: 31.8%). Agreement was low between diagnostic systems. Study findings provide support for an alternative latent dimensionality of DSM-5 PTSD in children and adolescents. The conceptualization of ICD-11 PTSD shows an excellent fit. Inconsistent PTSD constructs and significantly diverging diagnostic rates between DSM-5 and the ICD-11 will result in major challenges for researchers and clinicians in the field of psychotraumatology.
Kane, Jeremy C; Johnson, Renee M; Robinson, Courtland; Jernigan, David H; Harachi, Tracy W; Bass, Judith K
2016-02-01
Rates of alcohol use may be increasing among Asian-American adolescents. Among youth from Asian-immigrant families, intergenerational cultural dissonance (ICD), a difference in acculturation between children and caregivers, is associated with adverse childhood outcomes. This study investigates the longitudinal association of ICD and alcohol use among youth from immigrant Vietnamese and Cambodian families in the United States. Two waves of annual data, wave 4 (baseline for this study) and wave 5 (follow-up), were obtained from the Cross-Cultural Families Project, a longitudinal study of 327 Vietnamese and Cambodian immigrant families in Washington State. The Asian-American Family Conflicts Scale was used to measure ICD. Adolescent alcohol use was measured as any drinking in the past 30 days. A multiple logistic regression model was estimated with the outcome, alcohol use, measured at the follow-up visit and all predictors, including ICD, measured at baseline. Sex, nationality, nativity, and acculturation were tested as modifiers of the ICD-alcohol use relationship. Nine percent of adolescents (age range 13-18 years) reported alcohol use at baseline and this increased significantly (p < .0001) to 16% one year later. ICD was associated with increased odds of alcohol use at follow-up (odds ratio: 1.57; 95% confidence interval: 1.03-2.41; p = .04). None of the interactions were statistically significant. ICD is a significant predictor of alcohol use among Vietnamese and Cambodian adolescents. Interventions that should be targeted toward reducing ICD through enhancing parent-child communication and teaching bicultural competence skills may help prevent alcohol use problems among youth from immigrant families. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Consensus guidelines for the detection of immunogenic cell death
Kepp, Oliver; Senovilla, Laura; Vitale, Ilio; Vacchelli, Erika; Adjemian, Sandy; Agostinis, Patrizia; Apetoh, Lionel; Aranda, Fernando; Barnaba, Vincenzo; Bloy, Norma; Bracci, Laura; Breckpot, Karine; Brough, David; Buqué, Aitziber; Castro, Maria G.; Cirone, Mara; Colombo, Maria I.; Cremer, Isabelle; Demaria, Sandra; Dini, Luciana; Eliopoulos, Aristides G.; Faggioni, Alberto; Formenti, Silvia C.; Fučíková, Jitka; Gabriele, Lucia; Gaipl, Udo S.; Galon, Jérôme; Garg, Abhishek; Ghiringhelli, François; Giese, Nathalia A.; Guo, Zong Sheng; Hemminki, Akseli; Herrmann, Martin; Hodge, James W.; Holdenrieder, Stefan; Honeychurch, Jamie; Hu, Hong-Min; Huang, Xing; Illidge, Tim M.; Kono, Koji; Korbelik, Mladen; Krysko, Dmitri V.; Loi, Sherene; Lowenstein, Pedro R.; Lugli, Enrico; Ma, Yuting; Madeo, Frank; Manfredi, Angelo A.; Martins, Isabelle; Mavilio, Domenico; Menger, Laurie; Merendino, Nicolò; Michaud, Michael; Mignot, Gregoire; Mossman, Karen L.; Multhoff, Gabriele; Oehler, Rudolf; Palombo, Fabio; Panaretakis, Theocharis; Pol, Jonathan; Proietti, Enrico; Ricci, Jean-Ehrland; Riganti, Chiara; Rovere-Querini, Patrizia; Rubartelli, Anna; Sistigu, Antonella; Smyth, Mark J.; Sonnemann, Juergen; Spisek, Radek; Stagg, John; Sukkurwala, Abdul Qader; Tartour, Eric; Thorburn, Andrew; Thorne, Stephen H.; Vandenabeele, Peter; Velotti, Francesca; Workenhe, Samuel T.; Yang, Haining; Zong, Wei-Xing; Zitvogel, Laurence; Kroemer, Guido; Galluzzi, Lorenzo
2014-01-01
Apoptotic cells have long been considered as intrinsically tolerogenic or unable to elicit immune responses specific for dead cell-associated antigens. However, multiple stimuli can trigger a functionally peculiar type of apoptotic demise that does not go unnoticed by the adaptive arm of the immune system, which we named “immunogenic cell death” (ICD). ICD is preceded or accompanied by the emission of a series of immunostimulatory damage-associated molecular patterns (DAMPs) in a precise spatiotemporal configuration. Several anticancer agents that have been successfully employed in the clinic for decades, including various chemotherapeutics and radiotherapy, can elicit ICD. Moreover, defects in the components that underlie the capacity of the immune system to perceive cell death as immunogenic negatively influence disease outcome among cancer patients treated with ICD inducers. Thus, ICD has profound clinical and therapeutic implications. Unfortunately, the gold-standard approach to detect ICD relies on vaccination experiments involving immunocompetent murine models and syngeneic cancer cells, an approach that is incompatible with large screening campaigns. Here, we outline strategies conceived to detect surrogate markers of ICD in vitro and to screen large chemical libraries for putative ICD inducers, based on a high-content, high-throughput platform that we recently developed. Such a platform allows for the detection of multiple DAMPs, like cell surface-exposed calreticulin, extracellular ATP and high mobility group box 1 (HMGB1), and/or the processes that underlie their emission, such as endoplasmic reticulum stress, autophagy and necrotic plasma membrane permeabilization. We surmise that this technology will facilitate the development of next-generation anticancer regimens, which kill malignant cells and simultaneously convert them into a cancer-specific therapeutic vaccine. PMID:25941621
Reed, Geoffrey M; Sharan, Pratap; Rebello, Tahilia J; Keeley, Jared W; Elena Medina-Mora, María; Gureje, Oye; Luis Ayuso-Mateos, José; Kanba, Shigenobu; Khoury, Brigitte; Kogan, Cary S; Krasnov, Valery N; Maj, Mario; de Jesus Mari, Jair; Stein, Dan J; Zhao, Min; Akiyama, Tsuyoshi; Andrews, Howard F; Asevedo, Elson; Cheour, Majda; Domínguez-Martínez, Tecelli; El-Khoury, Joseph; Fiorillo, Andrea; Grenier, Jean; Gupta, Nitin; Kola, Lola; Kulygina, Maya; Leal-Leturia, Itziar; Luciano, Mario; Lusu, Bulumko; Nicolas, J; Martínez-López, I; Matsumoto, Chihiro; Umukoro Onofa, Lucky; Paterniti, Sabrina; Purnima, Shivani; Robles, Rebeca; Sahu, Manoj K; Sibeko, Goodman; Zhong, Na; First, Michael B; Gaebel, Wolfgang; Lovell, Anne M; Maruta, Toshimasa; Roberts, Michael C; Pike, Kathleen M
2018-06-01
Reliable, clinically useful, and globally applicable diagnostic classification of mental disorders is an essential foundation for global mental health. The World Health Organization (WHO) is nearing completion of the 11th revision of the International Classification of Diseases and Related Health Problems (ICD-11). The present study assessed inter-diagnostician reliability of mental disorders accounting for the greatest proportion of global disease burden and the highest levels of service utilization - schizophrenia and other primary psychotic disorders, mood disorders, anxiety and fear-related disorders, and disorders specifically associated with stress - among adult patients presenting for treatment at 28 participating centers in 13 countries. A concurrent joint-rater design was used, focusing specifically on whether two clinicians, relying on the same clinical information, agreed on the diagnosis when separately applying the ICD-11 diagnostic guidelines. A total of 1,806 patients were assessed by 339 clinicians in the local language. Intraclass kappa coefficients for diagnoses weighted by site and study prevalence ranged from 0.45 (dysthymic disorder) to 0.88 (social anxiety disorder) and would be considered moderate to almost perfect for all diagnoses. Overall, the reliability of the ICD-11 diagnostic guidelines was superior to that previously reported for equivalent ICD-10 guidelines. These data provide support for the suitability of the ICD-11 diagnostic guidelines for implementation at a global level. The findings will inform further revision of the ICD-11 diagnostic guidelines prior to their publication and the development of programs to support professional training and implementation of the ICD-11 by WHO member states. © 2018 World Psychiatric Association.
Biton, Yitschak; Huang, David T; Goldenberg, Ilan; Rosero, Spencer; Moss, Arthur J; Kutyifa, Valentina; McNitt, Scott; Strasberg, Boris; Zareba, Wojciech; Barsheshet, Alon
2016-04-01
There is limited data regarding the relationship between age and inappropriate therapy among patients with an implantable cardioverter-defibrillator (ICD) and resynchronization therapy. We aimed to investigate this relationship and the effect of ICD programming on inappropriate therapy by age. In the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) 1500 patients were randomized to 3 ICD programming arms: (A) conventional with ventricular tachycardia (VT) therapy ≥170; (B) high-rate cutoff with VT therapy ≥200, and (C) prolonged 60-second delay for VT therapy ≥170. We investigated the relationship between age, the risk of inappropriate ICD therapy (including antitachycardia pacing [ATP] or shock), and ICD programming. Cumulative incidence function Kaplan-Meier graphs showed an inverse relationship between increasing quartiles of age (Q1: ≤55, Q2: 56-64, Q3: 65-71, and Q4: ≥72 years) and the risk for inappropriate therapy. Multivariate analyses showed that each increasing decade of life was associated with 34% (P < .001), 27% (P < .001), and 26% (P < .001) reduction in the risk of inappropriate shock, inappropriate ATP, and any inappropriate therapy, respectively. Treatment arms B and C as compared with arm A were associated with a significant reduction in the risk of inappropriate therapies across all age quartiles (P < .001 for all). Among patients with a primary prevention indication for an ICD, there is an inverse relationship between age and inappropriate ICD therapy. Innovative ICD programming of high-rate cutoff or prolonged delay for VT therapy is associated with significant reductions in inappropriate therapy among all age groups. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Primary ICD-therapy in patients with advanced heart failure: selection strategies and future trials.
Frankenstein, Lutz; Zugck, Christian; Nelles, Manfred; Schellberg, Dieter; Remppis, Andrew; Katus, Hugo
2008-09-01
For allocation of primary ICD-therapy, a possible lower limit of inclusion criteria--defining overly advanced heart failure--is less well investigated. Also, a multi-variable approach to stratification beyond ejection fraction (LVEF) appears warranted. We examined whether adding a selection limit of peak VO(2)
Karatzias, Thanos; Shevlin, Mark; Fyvie, Claire; Hyland, Philip; Efthymiadou, Erifili; Wilson, Danielle; Roberts, Neil; Bisson, Jonathan I; Brewin, Chris R; Cloitre, Marylene
2017-01-01
The WHO International Classification of Diseases, 11th version (ICD-11), has proposed two related diagnoses following exposure to traumatic events; Posttraumatic Stress Disorder (PTSD) and Complex PTSD (CPTSD). We set out to explore whether the newly developed ICD-11 Trauma Questionnaire (ICD-TQ) can distinguish between classes of individuals according to the PTSD and CPTSD symptom profiles as per ICD-11 proposals based on latent class analysis. We also hypothesized that the CPTSD class would report more frequent and a greater number of different types of childhood trauma as well as higher levels of functional impairment. Methods Participants in this study were a sample of individuals who were referred for psychological therapy to a National Health Service (NHS) trauma centre in Scotland (N=193). Participants completed the ICD-TQ as well as measures of life events and functioning. Overall, results indicate that using the newly developed ICD-TQ, two subgroups of treatment-seeking individuals could be empirically distinguished based on different patterns of symptom endorsement; a small group high in PTSD symptoms only and a larger group high in CPTSD symptoms. In addition, CPTSD was more strongly associated with more frequent and a greater accumulation of different types of childhood traumatic experiences and poorer functional impairment. Sample predominantly consisted of people who had experienced childhood psychological trauma or been multiply traumatised in childhood and adulthood. CPTSD is highly prevalent in treatment seeking populations who have been multiply traumatised in childhood and adulthood and appropriate interventions should now be developed to aid recovery from this debilitating condition. Copyright © 2016 Elsevier B.V. All rights reserved.
Zeb, Mehmood; Curzen, Nick; Allavatam, Venugopal; Wilson, David; Yue, Arthur; Roberts, Paul; Morgan, John
2015-09-15
The sensitivity and specificity of the subcutaneous implantable cardioverter defibrillator (S-ICD) pre-implant screening tool required clinical evaluation. Bipolar vectors were derived from electrodes positioned at locations similar to those employed for S-ICD sensing and pre-implant screening electrodes, and recordings collected through 80-electrode PRIME®-ECGs, in six different postures, from 40 subjects (10 healthy controls, and 30 patients with complex congenital heart disease (CCHD); 10 with Tetralogy of Fallot (TOF), 10 with single ventricle physiology (SVP), and 10 with transposition of great arteries (TGA)). The resulting vectors were analysed using the S-ICD pre-implant screening tool (Boston Scientific) and processed through the sensing algorithm of S-ICD (Boston Scientific). The data were then evaluated using 2 × 2 contingency tables. Fisher exact and McNemar tests were used for a comparison of the different categories of CCHD, and p < 0.05 vs. controls considered to be statistically significant. 57% of patients were male, mean age of 36.3 years. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the S-ICD screening tool were 95%, 79%, 59% and 98%, respectively, for controls, and 84%, 79%, 76% and 86%, respectively, in patients with CCHD (p = 0.0001). The S-ICD screening tool was comparatively more sensitive in normal controls but less specific in both CCHD patients and controls; a possible explanation for the reported high incidence of inappropriate S-ICD shocks. Thus, we propose a pre-implant screening device using the S-ICD sensing algorithm to minimise false exclusion and selection, and hence minimise potentially inappropriate shocks. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Implementation and impact of ICD-10 (Part II).
Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E
2014-01-01
The transition from the International Classification of Disease-9(th) clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices.
O'Donnell, Meaghan L; Alkemade, Nathan; Nickerson, Angela; Creamer, Mark; McFarlane, Alexander C; Silove, Derrick; Bryant, Richard A; Forbes, David
2014-09-01
There have been changes to the criteria for diagnosing post-traumatic stress disorder (PTSD) in DSM-5 and changes are proposed for ICD-11. To investigate the impact of the changes to diagnostic criteria for PTSD in DSM-5 and the proposed changes in ICD-11 using a large multisite trauma-exposed sample and structured clinical interviews. Randomly selected injury patients admitted to four hospitals were assessed 72 months post trauma (n = 510). Structured clinical interviews for PTSD and major depressive episode, as well as self-report measures of disability and quality of life were administered. Current prevalence of PTSD under DSM-5 scoring was not significantly different from DSM-IV (6.7% v. 5.9%, z = 0.53, P = 0.59). However, the ICD-11 prevalence was significantly lower than ICD-10 (3.3% v. 9.0%, z = -3.8, P<0.001). The PTSD current prevalence was significantly higher for DSM-5 than ICD-11 (6.7% v. 3.3%, z = 2.5, P = 0.01). Using ICD-11 tended to show lower rates of comorbidity with depression and a slightly lower association with disability. The diagnostic systems performed in different ways in terms of current prevalence rates and levels of comorbidity with depression, but on other broad key indicators they were relatively similar. There was overlap between those with PTSD diagnosed by ICD-11 and DSM-5 but a substantial portion met one but not the other set of criteria. This represents a challenge for research because the phenotype that is studied may be markedly different according to the diagnostic system used. Royal College of Psychiatrists.
Eligibility and utilization of implantable cardioverter-defibrillators in a regional STEMI system.
Johnson, Benjamin K; Garberich, Ross F; Henry, Timothy D; Katsiyiannis, William T; Sengupta, Jay; Kalra, Ankur; Hauser, Robert G; Lardy, Meghan E; Newell, Marc C
2016-02-01
Studies have shown mortality benefit for implantable cardioverter-defibrillators (ICDs) in ST-elevation myocardial infarction (STEMI) patients with reduced left ventricular ejection fraction (LVEF), but contemporary eligibility and appropriate utilization of ICDs is unknown. The purpose of this study was to determine the contemporary eligibility and appropriate utilization of ICDs post-STEMI. Using the prospective Minneapolis Heart Institute regional STEMI registry, LVEF before discharge and at follow-up were stratified into 3 groups: normal (LVEF ≥50%), mildly reduced (LVEF 35%-49%), and severely reduced (LVEF <35%). From March 2003 to June 2012, 3626 patients were treated. Patients with in-hospital death (n = 187), ICD in place (n = 21), negative cardiac biomarkers (n = 337), and undocumented in-hospital LVEF (n = 9) were excluded, leaving 3072 patients in the final analysis, including 1833 (59.7%) with LVEF ≥50%, 875 (28.5%) with LVEF between 35% and 49%, and 364 (11.8%) with LVEF <35% before hospital discharge. Overall, 1029 patients (33.5%) underwent follow-up echocardiography ≥40 days post-STEMI, including 140 of the 364 patients (38.5%) discharged with LVEF <35%. In total, 73 patients (7.1%) with follow-up echocardiography ≥40 days post-STEMI met criteria for an ICD (68 LVEF ≤30%, 5 LVEF 30%-35%, and New York Heart Association class II or greater). Only 26 of these patients (35.6%) underwent ICD placement within 1 year post-STEMI. Overall, only 10% to 15% of potentially eligible patients had an ICD implemented. Rates of ICD implantation in appropriate STEMI patients after 40 days are low. Strategies are needed to identify and expand access to these high-risk patients. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Cho, En-Young Nicole; von Känel, Roland; Marten-Mittag, Birgit; Ronel, Joram; Kolb, Christof; Baumert, Jens; Ladwig, Karl-Heinz
2012-05-01
The implantable cardioverter defibrillator (ICD) is the gold standard therapy to prevent life-threatening arrhythmias. Phobic anxiety predicts ventricular arrhythmia in coronary heart disease patients, but little is known about phobic anxiety in ICD patients. This study aimed to identify determinants and the course of phobic anxiety in ICD patients. 140 outpatients living with an ICD (mean age 56±14 years, 66% men). Phobic anxiety was assessed with the Symptom Checklist-90 Revised at a mean of 27±21 months (range 3-109) post-ICD placement (baseline) and after an average follow-up of 41±18 months (range 10-82). Multivariate linear regression models considered sociodemographic factors, clinical variables and psychological scales as potential determinants of phobic anxiety scores. ICD patients reported more than 10-fold higher levels of phobic anxiety than a previous representative population survey (2.6±3.4 vs 0.2±0.4). Greater age (p=0.003), previous shock experience (p=0.007), depressed mood (p<0.001) and hypochondriasis (p=0.005) were associated with higher phobic anxiety scores at baseline. Multimorbidity (p=0.030) and higher baseline phobic anxiety (p<0.001) determined greater phobic anxiety at follow-up. Younger age (p=0.029) and an elevated number of non-cardiac diseases (p=0.019) were both associated with an increase in phobic anxiety scores from baseline to follow-up. More patients had high phobic anxiety levels (score >4) at follow-up compared with baseline (31% vs 24%; p=0.048). Phobic anxiety was comparably high and persisted over time in ICD patients. Modifiable determinants of phobic anxiety were identified, which may inform tailored interventions to improve ICD patients' distress and perhaps also prognosis.
Street, J T; Thorogood, N P; Cheung, A; Noonan, V K; Chen, J; Fisher, C G; Dvorak, M F
2013-06-01
Observational cohort comparison. To compare the previously validated Spine Adverse Events Severity system (SAVES) with International Classification of Diseases, Tenth Revision codes (ICD-10) codes for identifying adverse events (AEs) in patients with traumatic spinal cord injury (TSCI). Quaternary Care Spine Program. Patients discharged between 2006 and 2010 were identified from our prospective registry. Two consecutive cohorts were created based on the system used to record acute care AEs; one used ICD-10 coding by hospital coders and the other used SAVES data prospectively collected by a multidisciplinary clinical team. The ICD-10 codes were appropriately mapped to the SAVES. There were 212 patients in the ICD-10 cohort and 173 patients in the SAVES cohort. Analyses were adjusted to account for the different sample sizes, and the two cohorts were comparable based on age, gender and motor score. The SAVES system identified twice as many AEs per person as ICD-10 coding. Fifteen unique AEs were more reliably identified using SAVES, including neuropathic pain (32 × more; P<0.001), urinary tract infections (1.4 × ; P<0.05), pressure sores (2.9 × ; P<0.001) and intra-operative AEs (2.3 × ; P<0.05). Eight of these 15 AEs more frequently identified by SAVES significantly impacted length of stay (P<0.05). Risk factors such as patient age and severity of paralysis were more reliably correlated to AEs collected through SAVES than ICD-10. Implementation of the SAVES system for patients with TSCI captured more individuals experiencing AEs and more AEs per person compared with ICD-10 codes. This study demonstrates the utility of prospectively collecting AE data using validated tools.
Wu, Bo; Zhou, Yang; Wang, Yu; Yang, Xiang-Min; Liu, Zhen-Yu; Li, Jiang-Hua; Feng, Fei; Chen, Zhi-Nan; Jiang, Jian-Li
2016-01-01
Hepatocellular carcinoma (HCC) is currently the third most common cause of cancer-related death in the Asia-Pacific region. Our previous work showed that knockdown of CD98 significantly inhibits malignant HCC cell phenotypes in vitro and in vivo. The level of CD98 in the membrane is tightly regulated to mediate complex processes associated with cell–cell communication and intracellular signaling. In addition, the intracellular domain of CD98 (CD98-ICD) seems to be of vital importance for recycling CD98 to the membrane after it is endocytosed. The intracellular and transmembrane domains of CD98 associate with β-integrins (primarily β1 but also β3), and this association is essential for CD98 mediation of integrin-like signaling and complements dominant suppression of β1-integrin. We speculated that isolated CD98-ICD would similarly suppress β1-integrin activation and inhibit the malignant behaviors of cancer cells. In particular, the exact role of CD98-ICD has not been studied independently in HCC. In this study, we found that ectopic expression of CD98-ICD inhibited the malignant phenotypes of HCC cells, and the mechanism possibly involves β1-integrin suppression. Moreover, the expression levels of CD98, β1-integrin-A (the activated form of β1-integrin) and Ki-67 were significantly increased in HCC tissues relative to those of normal liver tissues. Therefore, our preliminary study indicates that ectopic CD98-ICD has an inhibitory role in the malignant development of HCC, and shows that CD98-ICD acts as a dominant negative mutant of CD98 that attenuates β1-integrin activation. CD98-ICD may emerge as a promising candidate for antitumor treatment. PMID:27834933
Steps through the revision process of reproductive health sections of ICD-11.
Chou, Doris; Tunçalp, Özge; Hotamisligil, Selen; Norman, Jane; Say, Lale; Volkmer, Björn; Pattinson, Bob; Rooney, Cleo; Serour, Gamal; de Mouzon, Jacques; Gardosi, Jason; Thueroff, Joachim; Mark, Morgan; D'Hooghe, Thomas
2012-01-01
In 2007, the WHO initiated an organizational structure for the 11th revision of the International Classification of Diseases (ICD). Effective deployment of ICD-derived tools facilitates the use and collection of health information in a variety of resource settings, promoting quantitatively informed decisions. They also facilitate comparison of disease incidence and outcomes between different countries and different health care systems around the world. The Department of Reproductive Health and Research (RHR) coordinates the revision of chapters 14 (diseases of the genitourinary system), 15 (pregnancy, childbirth, and puerperium), and 16 (conditions originating in the perinatal period). RHR convened a technical advisory group (TAG), the Genito-Urinary Reproductive Medicine (GURM) TAG, for the ICD revision. The TAG's work reflects the collective understanding of sexual and reproductive health and is now available for review within the ICD-11 revision process. Copyright © 2012 S. Karger AG, Basel.
Effective Identification of Similar Patients Through Sequential Matching over ICD Code Embedding.
Nguyen, Dang; Luo, Wei; Venkatesh, Svetha; Phung, Dinh
2018-04-11
Evidence-based medicine often involves the identification of patients with similar conditions, which are often captured in ICD (International Classification of Diseases (World Health Organization 2013)) code sequences. With no satisfying prior solutions for matching ICD-10 code sequences, this paper presents a method which effectively captures the clinical similarity among routine patients who have multiple comorbidities and complex care needs. Our method leverages the recent progress in representation learning of individual ICD-10 codes, and it explicitly uses the sequential order of codes for matching. Empirical evaluation on a state-wide cancer data collection shows that our proposed method achieves significantly higher matching performance compared with state-of-the-art methods ignoring the sequential order. Our method better identifies similar patients in a number of clinical outcomes including readmission and mortality outlook. Although this paper focuses on ICD-10 diagnosis code sequences, our method can be adapted to work with other codified sequence data.
Efficient HIK SVM learning for image classification.
Wu, Jianxin
2012-10-01
Histograms are used in almost every aspect of image processing and computer vision, from visual descriptors to image representations. Histogram intersection kernel (HIK) and support vector machine (SVM) classifiers are shown to be very effective in dealing with histograms. This paper presents contributions concerning HIK SVM for image classification. First, we propose intersection coordinate descent (ICD), a deterministic and scalable HIK SVM solver. ICD is much faster than, and has similar accuracies to, general purpose SVM solvers and other fast HIK SVM training methods. We also extend ICD to the efficient training of a broader family of kernels. Second, we show an important empirical observation that ICD is not sensitive to the C parameter in SVM, and we provide some theoretical analyses to explain this observation. ICD achieves high accuracies in many problems, using its default parameters. This is an attractive property for practitioners, because many image processing tasks are too large to choose SVM parameters using cross-validation.
Nisam, Seah; Reddy, Shantanu
2015-05-01
The totally transvenous implantable defibrillator lead, conceived by Mirowski and Mower 45 years ago, is irrevocably related to the wide acceptance of this therapy. It paved the way for the era for non-thoracotomy implantation. This paper covers the most important details of the evolution--over this 45-year period--of the original (ENDOTAK) transvenous ICD lead and subsequent iterations. Over that time period, there have been over 800 000 patients implanted with this family of leads. The 'story' addresses the multiple problems encountered, technological improvements in materials, design, and testing to overcome them. And, the need for continued close collaboration between physicians and industry focused on reliability and longevity of this critical component of these life-saving systems. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Electromagnetic Interference in a Private Swimming Pool: Case report.
Iskandar, Sandia; Lavu, Madhav; Atoui, Moustapha; Lakkireddy, Dhanunjaya
2015-01-01
Although current lead design and filtering capabilities have greatly improved, Electromagnetic Interference (EMI) from environmental sources has been increasingly reported in patients with Cardiac Implantable Electronic Device (CIED) [1]. Few cases of inappropriate intracardiac Cardioverter Defibrillator (ICD) associated with swimming pool has been described [2]. Here we present a case of 64 year old male who presented with an interesting EMI signal that was subsequently identified to be related to AC current leak in his swimming pool.
Clinician's Primer to ICD-10-CM Coding for Cleft Lip/Palate Care.
Allori, Alexander C; Cragan, Janet D; Della Porta, Gina C; Mulliken, John B; Meara, John G; Bruun, Richard; Shusterman, Stephen; Cassell, Cynthia H; Raynor, Eileen; Santiago, Pedro; Marcus, Jeffrey R
2017-01-01
On October 1, 2015, the United States required use of the Clinical Modification of the International Classification of Diseases, 10th Revision (ICD-10-CM) for diagnostic coding. This primer was written to assist the cleft care community with understanding and use of ICD-10-CM for diagnostic coding related to cleft lip and/or palate (CL/P).
Far-Infrared Emission of Intracluster Dust (ICD)
NASA Astrophysics Data System (ADS)
Arimoto, N.; Takagi, T.; Hanami, H.
2000-12-01
In the young universe, clusters of galaxies could be bright FIR-Submm sources due to the dust emissions from young ellipticals. The intracluster dust (ICD) could also contribute to the FIR-Submm emissions considerably, but the ICD is fragile in the ambient hot ICM. Therefore, a chance to detect the ICD emission would be much smaller than the dust emissions from galaxies. Dust emissions from elliptical galaxies (EROs) in the young Coma cluster at a distance of z=2-3 would be easily detected by a future mission of H2L2 satellite, thus the FIR-Submm survey would become a powerful tool for searching high-z clusters.
Vriend, Chris
2018-01-30
Impulse control disorders (ICD) are common neuropsychiatric disorders that can arise in Parkinson's disease (PD) patients after commencing dopamine replacement therapy. Approximately 15% of all patients develop these disorders and many more exhibit subclinical symptoms of impulsivity. ICD is thought to develop due to an interaction between the use of dopaminergic medication and an as yet unknown neurobiological vulnerability that either pre-existed before PD onset (possibly genetic) or is associated with neural alterations due to the PD pathology. This review discusses genes, neurotransmitters and neural networks that have been implicated in the pathophysiology of ICD in PD. Although dopamine and the related reward system have been the main focus of research, recently, studies have started to look beyond those systems to find new clues to the neurobiological underpinnings of ICD and come up with possible new targets for treatment. Studies on the whole-brain connectome to investigate the global alterations due to ICD development are currently lacking. In addition, there is a dire need for longitudinal studies that are able to disentangle the contributions of individual (genetic) traits and secondary effects of the PD pathology and chronic dopamine replacement therapy to the development of ICD in PD.
Washizuka, Takashi; Chinushi, Masaomi; Watanabe, Hiroshi; Hosaka, Yukio; Komura, Satoru; Sugiura, Hirotaka; Hirono, Takashi; Furushima, Hiroshi; Tanabe, Yasutaka; Aizawa, Yoshifusa
2005-12-01
Some patients with an implantable cardioverter-defibrillator (ICD) suffer from burst of inappropriate multiple discharges (severe electrical storm), and because the current therapeutic options are limited, the effect of nifekalant hydrochloride, a new class III drug, on severe electrical storm was investigated in the present study. Ninety-one consecutive patients treated with ICD were included in the study (M 70; mean age 58 years; left ventricular ejection fraction 45+/-15%). Severe electrical storm was defined as more than 10 ICD discharges within 1 h. During a mean follow-up period of 30+/-13 months, 41/91 (45%) patients had appropriate ICD therapy for arrhythmias and severe electrical storm occurred in 11 of them (12%) at 20+/-18 months after ICD implantation. The mean number of ICD discharges/h during severe electrical storm was 18+/-12. In 4 of 10 patients, severe electrical storm was successfully suppressed by a combination of deep sedation and beta-blocking agent; 6 other patients were refractory to this treatment, but severe electrical storm was successfully suppressed by intravenous administration of nifekalant hydrochloride with no adverse effects. Nifekalant hydrochloride is an effective and safe treatment for severe electrical storm.