NASA Astrophysics Data System (ADS)
Marhadi, Kun Saptohartyadi
Structural optimization for damage tolerance under various unforeseen damage scenarios is computationally challenging. It couples non-linear progressive failure analysis with sampling-based stochastic analysis of random damage. The goal of this research was to understand the relationship between alternate load paths available in a structure and its damage tolerance, and to use this information to develop computationally efficient methods for designing damage tolerant structures. Progressive failure of a redundant truss structure subjected to small random variability was investigated to identify features that correlate with robustness and predictability of the structure's progressive failure. The identified features were used to develop numerical surrogate measures that permit computationally efficient deterministic optimization to achieve robustness and predictability of progressive failure. Analysis of damage tolerance on designs with robust progressive failure indicated that robustness and predictability of progressive failure do not guarantee damage tolerance. Damage tolerance requires a structure to redistribute its load to alternate load paths. In order to investigate the load distribution characteristics that lead to damage tolerance in structures, designs with varying degrees of damage tolerance were generated using brute force stochastic optimization. A method based on principal component analysis was used to describe load distributions (alternate load paths) in the structures. Results indicate that a structure that can develop alternate paths is not necessarily damage tolerant. The alternate load paths must have a required minimum load capability. Robustness analysis of damage tolerant optimum designs indicates that designs are tailored to specified damage. A design Optimized under one damage specification can be sensitive to other damages not considered. Effectiveness of existing load path definitions and characterizations were investigated for continuum structures. A load path definition using a relative compliance change measure (U* field) was demonstrated to be the most useful measure of load path. This measure provides quantitative information on load path trajectories and qualitative information on the effectiveness of the load path. The use of the U* description of load paths in optimizing structures for effective load paths was investigated.
NASA Technical Reports Server (NTRS)
Horne, Michael R.; Madaras, Eric I.
2010-01-01
Failure tests of CCM SM/ALAS (Composite Crew Module Service Module / Alternate Launch Abort System) composite panels were conducted during July 10, 2008 and July 24, 2008 at Langley Research Center. This is a report of the analysis of the Acoustic Emission (AE) data collected during those tests.
Predictive failure analysis: planning for the worst so that it never happens!
Hipple, Jack
2008-01-01
This article reviews an alternative approach to failure analysis involving a deliberate saboteurial approach rather than a checklist approach to disaster and emergency preparedness. This process is in the form of an algorithm that is easily applied to any planning situation.
Failure Analysis of CCD Image Sensors Using SQUID and GMR Magnetic Current Imaging
NASA Technical Reports Server (NTRS)
Felt, Frederick S.
2005-01-01
During electrical testing of a Full Field CCD Image Senor, electrical shorts were detected on three of six devices. These failures occurred after the parts were soldered to the PCB. Failure analysis was performed to determine the cause and locations of these failures on the devices. After removing the fiber optic faceplate, optical inspection was performed on the CCDs to understand the design and package layout. Optical inspection revealed that the device had a light shield ringing the CCD array. This structure complicated the failure analysis. Alternate methods of analysis were considered, including liquid crystal, light and thermal emission, LT/A, TT/A SQUID, and MP. Of these, SQUID and MP techniques were pursued for further analysis. Also magnetoresistive current imaging technology is discussed and compared to SQUID.
Characterization of emission microscopy and liquid crystal thermography in IC fault localization
NASA Astrophysics Data System (ADS)
Lau, C. K.; Sim, K. S.
2013-05-01
This paper characterizes two fault localization techniques - Emission Microscopy (EMMI) and Liquid Crystal Thermography (LCT) by using integrated circuit (IC) leakage failures. The majority of today's semiconductor failures do not reveal a clear visual defect on the die surface and therefore require fault localization tools to identify the fault location. Among the various fault localization tools, liquid crystal thermography and frontside emission microscopy are commonly used in most semiconductor failure analysis laboratories. Many people misunderstand that both techniques are the same and both are detecting hot spot in chip failing with short or leakage. As a result, analysts tend to use only LCT since this technique involves very simple test setup compared to EMMI. The omission of EMMI as the alternative technique in fault localization always leads to incomplete analysis when LCT fails to localize any hot spot on a failing chip. Therefore, this research was established to characterize and compare both the techniques in terms of their sensitivity in detecting the fault location in common semiconductor failures. A new method was also proposed as an alternative technique i.e. the backside LCT technique. The research observed that both techniques have successfully detected the defect locations resulted from the leakage failures. LCT wass observed more sensitive than EMMI in the frontside analysis approach. On the other hand, EMMI performed better in the backside analysis approach. LCT was more sensitive in localizing ESD defect location and EMMI was more sensitive in detecting non ESD defect location. Backside LCT was proven to work as effectively as the frontside LCT and was ready to serve as an alternative technique to the backside EMMI. The research confirmed that LCT detects heat generation and EMMI detects photon emission (recombination radiation). The analysis results also suggested that both techniques complementing each other in the IC fault localization. It is necessary for a failure analyst to use both techniques when one of the techniques produces no result.
Williams, Scott G
2006-03-01
To examine the impact of detection biases on three prostate cancer biochemical failure (bF) definitions in comparison with the existing American Society for Therapeutic Radiology and Oncology Consensus Definition (ACD). Three alternative bF definitions were tested against the ACD: three rises in prostate-specific antigen (PSA) level without backdating, nadir plus 2 ng/mL, and a threshold PSA level of >3 ng/mL, according to data from 1050 men. The mean time between PSA tests (MTBT), regularity of collection, and calendar year of analysis were examined in each bF definition. The MTBT produced a statistically significant difference in the derived hazard ratio for identification of bF in all definitions. The influence of test regularity was statistically significant beyond the median level of regularity in all definitions. The year of analysis impacted greatly on the ACD, whereas the three alternative definitions exhibited minor follow-up duration variations by comparison. The alternative definitions had reliable follow-up when the crude median time to censoring was at least 1.6 times greater than that of failure. Detection biases will always be a significant issue in defining bF. A number of alternative failure definitions have more predictable interactions with these biases than the existing ACD.
NASA Technical Reports Server (NTRS)
Phillips, D. T.; Manseur, B.; Foster, J. W.
1982-01-01
Alternate definitions of system failure create complex analysis for which analytic solutions are available only for simple, special cases. The GRASP methodology is a computer simulation approach for solving all classes of problems in which both failure and repair events are modeled according to the probability laws of the individual components of the system.
Alternative Splicing of NOX4 in the Failing Human Heart
Varga, Zoltán V.; Pipicz, Márton; Baán, Júlia A.; Baranyai, Tamás; Koncsos, Gábor; Leszek, Przemyslaw; Kuśmierczyk, Mariusz; Sánchez-Cabo, Fátima; García-Pavía, Pablo; Brenner, Gábor J.; Giricz, Zoltán; Csont, Tamás; Mendler, Luca; Lara-Pezzi, Enrique; Pacher, Pál; Ferdinandy, Péter
2017-01-01
Increased oxidative stress is a major contributor to the development and progression of heart failure, however, our knowledge on the role of the distinct NADPH oxidase (NOX) isoenzymes, especially on NOX4 is controversial. Therefore, we aimed to characterize NOX4 expression in human samples from healthy and failing hearts. Explanted human heart samples (left and right ventricular, and septal regions) were obtained from patients suffering from heart failure of ischemic or dilated origin. Control samples were obtained from donor hearts that were not used for transplantation. Deep RNA sequencing of the cardiac transcriptome indicated extensive alternative splicing of the NOX4 gene in heart failure as compared to samples from healthy donor hearts. Long distance PCR analysis with a universal 5′-3′ end primer pair, allowing amplification of different splice variants, confirmed the presence of the splice variants. To assess translation of the alternatively spliced transcripts we determined protein expression of NOX4 by using a specific antibody recognizing a conserved region in all variants. Western blot analysis showed up-regulation of the full-length NOX4 in ischemic cardiomyopathy samples and confirmed presence of shorter isoforms both in control and failing samples with disease-associated expression pattern. We describe here for the first time that NOX4 undergoes extensive alternative splicing in human hearts which gives rise to the expression of different enzyme isoforms. The full length NOX4 is significantly upregulated in ischemic cardiomyopathy suggesting a role for NOX4 in ROS production during heart failure. PMID:29204124
NASA Astrophysics Data System (ADS)
Li, N.; Cheng, Y. M.
2015-01-01
Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient detail. There is however increasing interest in the consequences after the initiation of failure that includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more detail and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and a laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanisms and the post-failure mechanisms of slopes will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure, which can give additional information not available from the classical methods of analysis.
Laboratory and 3-D-distinct element analysis of failure mechanism of slope under external surcharge
NASA Astrophysics Data System (ADS)
Li, N.; Cheng, Y. M.
2014-09-01
Landslide is a major disaster resulting in considerable loss of human lives and property damages in hilly terrain in Hong Kong, China and many other countries. The factor of safety and the critical slip surface for slope stabilization are the main considerations for slope stability analysis in the past, while the detailed post-failure conditions of the slopes have not been considered in sufficient details. There are however increasing interest on the consequences after the initiation of failure which includes the development and propagation of the failure surfaces, the amount of failed mass and runoff and the affected region. To assess the development of slope failure in more details and to consider the potential danger of slopes after failure has initiated, the slope stability problem under external surcharge is analyzed by the distinct element method (DEM) and laboratory model test in the present research. A more refined study about the development of failure, microcosmic failure mechanism and the post-failure mechanism of slope will be carried out. The numerical modeling method and the various findings from the present work can provide an alternate method of analysis of slope failure which can give additional information not available from the classical methods of analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, D. G.; Arent, D. J.; Johnson, L.
2006-06-01
This paper documents a probabilistic risk assessment of existing and alternative power supply systems at a large telecommunications office. The analysis characterizes the increase in the reliability of power supply through the use of two alternative power configurations. Failures in the power systems supporting major telecommunications service nodes are a main contributor to significant telecommunications outages. A logical approach to improving the robustness of telecommunication facilities is to increase the depth and breadth of technologies available to restore power during power outages. Distributed energy resources such as fuel cells and gas turbines could provide additional on-site electric power sources tomore » provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less
A Monte Carlo Risk Analysis of Life Cycle Cost Prediction.
1975-09-01
process which occurs with each FLU failure. With this in mind there is no alternative other than the binomial distribution. 24 GOR/SM/75D-6 With all of...Weibull distribution of failures as selected by user. For each failure of the ith FLU, the model then samples from the binomial distribution to deter- mine...which is sampled from the binomial . Neither of the two conditions for normality are met, i.e., that RTS Ie close to .5 and the number of samples close
The Design and Implementation of an Alternative High School.
ERIC Educational Resources Information Center
Kritek, William J.
The analysis of the planning for an implementation of an alternative high school in a large urban school system is the focus of this study. Interview data are used. This investigation draws on, and compliments, the previous literature on implementation. While most of the earlier studies look at failures, this one is based on an instance of…
Broët, Philippe; Tsodikov, Alexander; De Rycke, Yann; Moreau, Thierry
2004-06-01
This paper presents two-sample statistics suited for testing equality of survival functions against improper semi-parametric accelerated failure time alternatives. These tests are designed for comparing either the short- or the long-term effect of a prognostic factor, or both. These statistics are obtained as partial likelihood score statistics from a time-dependent Cox model. As a consequence, the proposed tests can be very easily implemented using widely available software. A breast cancer clinical trial is presented as an example to demonstrate the utility of the proposed tests.
Koziol, Mateusz; Figlus, Tomasz
2015-12-14
The work aimed to assess the failure progress in a glass fiber-reinforced polymer laminate with a 3D-woven and (as a comparison) plain-woven reinforcement, during static bending, using acoustic emission signals. The innovative method of the separation of the signal coming from the fiber fracture and the one coming from the matrix fracture with the use of the acoustic event's energy as a criterion was applied. The failure progress during static bending was alternatively analyzed by evaluation of the vibration signal. It gave a possibility to validate the results of the acoustic emission. Acoustic emission, as well as vibration signal analysis proved to be good and effective tools for the registration of failure effects in composite laminates. Vibration analysis is more complicated methodologically, yet it is more precise. The failure progress of the 3D laminate is "safer" and more beneficial than that of the plain-woven laminate. It exhibits less rapid load capacity drops and a higher fiber effort contribution at the moment of the main laminate failure.
BROËT, PHILIPPE; TSODIKOV, ALEXANDER; DE RYCKE, YANN; MOREAU, THIERRY
2010-01-01
This paper presents two-sample statistics suited for testing equality of survival functions against improper semi-parametric accelerated failure time alternatives. These tests are designed for comparing either the short- or the long-term effect of a prognostic factor, or both. These statistics are obtained as partial likelihood score statistics from a time-dependent Cox model. As a consequence, the proposed tests can be very easily implemented using widely available software. A breast cancer clinical trial is presented as an example to demonstrate the utility of the proposed tests. PMID:15293627
Wind Turbine Failures - Tackling current Problems in Failure Data Analysis
NASA Astrophysics Data System (ADS)
Reder, M. D.; Gonzalez, E.; Melero, J. J.
2016-09-01
The wind industry has been growing significantly over the past decades, resulting in a remarkable increase in installed wind power capacity. Turbine technologies are rapidly evolving in terms of complexity and size, and there is an urgent need for cost effective operation and maintenance (O&M) strategies. Especially unplanned downtime represents one of the main cost drivers of a modern wind farm. Here, reliability and failure prediction models can enable operators to apply preventive O&M strategies rather than corrective actions. In order to develop these models, the failure rates and downtimes of wind turbine (WT) components have to be understood profoundly. This paper is focused on tackling three of the main issues related to WT failure analyses. These are, the non-uniform data treatment, the scarcity of available failure analyses, and the lack of investigation on alternative data sources. For this, a modernised form of an existing WT taxonomy is introduced. Additionally, an extensive analysis of historical failure and downtime data of more than 4300 turbines is presented. Finally, the possibilities to encounter the lack of available failure data by complementing historical databases with Supervisory Control and Data Acquisition (SCADA) alarms are evaluated.
Finite element assisted prediction of ductile fracture in sheet bulging
NASA Astrophysics Data System (ADS)
Donald, Bryan J. Mac; Lorza, Ruben Lostado; Yoshihara, Shoichiro
2017-10-01
With growing demand for energy efficiency, there is much focus on reducing oil consumption rates and utilising alternative fuels. A contributor to the solution in this area is to produce lighter vehicles that are more fuel efficient and/or allow for the use of alternative fuel sources (e.g. electric powered automobiles). Near-net-shape manufacturing processes such as hydroforming have great potential to reduce structural weight while still maintaining structural strength and performance. Finite element analysis techniques have proved invaluable in optimizing such hydroforming processes, however, the majority of such studies have used simple predictors of failure which are usually yield criteria such as von Mises stress. There is clearly potential to obtain more optimal solutions using more advanced predictors of failure. This paper compared the Von Mises stress failure criteria and the Oyane's ductile fracture criteria in the sheet hydroforming of magnesium alloys. It was found that the results obtained from the models which used Oyane's ductile fracture criteria were more realistic than those obtained from those that used Von Mises stress as a failure criteria.
NASA Technical Reports Server (NTRS)
Williams, F. E.; Lemon, R. S.
1974-01-01
The investigation of single actuator failures on the space shuttle solid rocket booster required the analysis of both square pattern and diamond pattern actuator configurations. It was determined that for failures occuring near or prior to the region of maximum dynamic pressure, control gain adjustments can be used to achieve virtually nominal mid-boost vehicle behavior. A distinct worst case failure condition was established near staging that could significantly delay staging. It is recommended that the square pattern be retained as a viable alternative to the baseline diamond pattern because the staging transient is better controlled resulting in earlier staging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Homce, G.T.; Thalimer, J.R.
1996-05-01
Most electric motor predictive maintenance methods have drawbacks that limit their effectiveness in the mining environment. The US Bureau of Miens (USBM) is developing an alternative approach to detect winding insulation breakdown in advance of complete motor failure. In order to evaluate the analysis algorithms necessary for this approach, the USBM has designed and installed a system to monitor 120 electric motors in a coal preparation plant. The computer-based experimental system continuously gathers, stores, and analyzes electrical parameters for each motor. The results are then correlated to data from conventional motor-maintenance methods and in-service failures to determine if the analysismore » algorithms can detect signs of insulation deterioration and impending failure. This paper explains the on-line testing approach used in this research, and describes monitoring system design and implementation. At this writing data analysis is underway, but conclusive results are not yet available.« less
Actuator digital interface unit (AIU). [control units for space shuttle data system
NASA Technical Reports Server (NTRS)
1973-01-01
Alternate versions of the actuator interface unit are presented. One alternate is a dual-failure immune configuration which feeds a look-and-switch dual-failure immune hydraulic system. The other alternate is a single-failure immune configuration which feeds a majority voting hydraulic system. Both systems communicate with the data bus through data terminals dedicated to each user subsystem. Both operational control data and configuration control information are processed in and out of the subsystem via the data terminal which yields the actuator interface subsystem, self-managing within its failure immunity capability.
Analytical and experimental evaluation of an aluminum bridge deck panel. Part 2, failure analysis.
DOT National Transportation Integrated Search
1999-01-01
Aluminum bridge decks may prove to be an alternative to concrete decks for improving the performance of structural bridge systems. Combining excellent corrosion resistance with extremely low density, aluminum decks can prolong surface life, facilitat...
An Independent Evaluation of the FMEA/CIL Hazard Analysis Alternative Study
NASA Technical Reports Server (NTRS)
Ray, Paul S.
1996-01-01
The present instruments of safety and reliability risk control for a majority of the National Aeronautics and Space Administration (NASA) programs/projects consist of Failure Mode and Effects Analysis (FMEA), Hazard Analysis (HA), Critical Items List (CIL), and Hazard Report (HR). This extensive analytical approach was introduced in the early 1970's and was implemented for the Space Shuttle Program by NHB 5300.4 (1D-2. Since the Challenger accident in 1986, the process has been expanded considerably and resulted in introduction of similar and/or duplicated activities in the safety/reliability risk analysis. A study initiated in 1995, to search for an alternative to the current FMEA/CIL Hazard Analysis methodology generated a proposed method on April 30, 1996. The objective of this Summer Faculty Study was to participate in and conduct an independent evaluation of the proposed alternative to simplify the present safety and reliability risk control procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joergensen, O.; Horsewell, A.
1997-08-01
Elastic and elasto-plastic modelling of indentation in CFRP cross-ply laminates has been performed. Detailed knowledge of the field solutions in the volume below the indentor forms the basis for the reported micromechanical interpretation of the observed damage in test specimens. The analysis shows that matrix cracks originate at sites of maximum tensile stress perpendicular to fibers. The predicted stress fields due to indentation show that stress concentrations occur in the interface between alternating plies. It is found that microcracking in this zone is a precursor to the observed failure. This analysis is supported by in-situ scanning electron microscopy during loadingmore » by a cylindrical indentor onto the laminate supported on a rigid substrate. The microscopy reveals microdamage in the region of interfacial tensile stress concentrations. The onset of indentation failure in these layered composites suggests that plastic interleaves would delay failure. It is shown numerically that plastic deformation of the interleaves redistributes stresses and thereby weakens the tensile stress concentrations which arise during indentation. Experimentally it is shown that aluminium interleaves affect the formation of indentation failure. In a cross-ply laminate, where alternating ply groups are separated by aluminium sheets, matrix cracking and delamination failures are suppressed by the occurrence of plastic deformation. Since the aluminium is likely to be weakly bonded to the plies, it is seen that weak interlaminar fracture toughness does not necessarily cause delaminations, nor lead to a lower indentation strength. High indentation strength and delamination resistance are complex qualities which, among others, seem to be achieved in laminate geometries which have a minimum of stress concentration at interfaces between ply groups of different orientation.« less
Is it possible to identify a trend in problem/failure data
NASA Technical Reports Server (NTRS)
Church, Curtis K.
1990-01-01
One of the major obstacles in identifying and interpreting a trend is the small number of data points. Future trending reports will begin with 1983 data. As the problem/failure data are aggregated by year, there are just seven observations (1983 to 1989) for the 1990 reports. Any statistical inferences with a small amount of data will have a large degree of uncertainty. Consequently, a regression technique approach to identify a trend is limited. Though trend determination by failure mode may be unrealistic, the data may be explored for consistency or stability and the failure rate investigated. Various alternative data analysis procedures are briefly discussed. Techniques that could be used to explore problem/failure data by failure mode are addressed. The data used are taken from Section One, Space Shuttle Main Engine, of the Calspan Quarterly Report dated April 2, 1990.
Pre-mRNA mis-splicing of sarcomeric genes in heart failure.
Zhu, Chaoqun; Chen, Zhilong; Guo, Wei
2017-08-01
Pre-mRNA splicing is an important biological process that allows production of multiple proteins from a single gene in the genome, and mainly contributes to protein diversity in eukaryotic organisms. Alternative splicing is commonly governed by RNA binding proteins to meet the ever-changing demands of the cell. However, the mis-splicing may lead to human diseases. In the heart of human, mis-regulation of alternative splicing has been associated with heart failure. In this short review, we focus on alternative splicing of sarcomeric genes and review mis-splicing related heart failure with relatively well studied Sarcomeric genes and splicing mechanisms with identified regulatory factors. The perspective of alternative splicing based therapeutic strategies in heart failure has also been discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Broyles, R W; Narine, L; Khaliq, A
2003-08-01
This paper modifies traditional break-even analysis and develops a model that reflects the influence of variation in payer mix, the collection rate, profitability and autonomous income on the desired volume alternative. The augmented model indicates that a failure to adjust for uncollectibles and the net surplus results in a systematic understatement of the desired volume alternative. Conversely, a failure to adjust for autonomous income derived from the operation of cafeterias, gift shops or an organization's investment in marketable securities produces an overstatement of the desired volume. In addition, this paper uses Microsoft Excel to develop a spreadsheet that constructs a pro forma income statement, expressed in terms of the contribution margin. The spreadsheet also relies on the percentage of sales or revenue approach to prepare a balance sheet from which indicators of fiscal performance are calculated. Hence, the analysis enables the organization to perform a sensitivity analysis of potential changes in the desired volume, the operating margin, the current ratio, the debt: equity ratio and the amount of cash derived from operations that are associated with expected variation in payer mix, the collection rate, grouped by payer, the net surplus and autonomous income.
2005-05-01
Center (PEC) guidelines on therapeutic failure. Such guidelines recommend atorvastatin as an alternative agent in patients who had a bona fide failure...on simvastatin. Failures requiring atorvastatin as an alternate agent were defined as (a) patients not at their LDL goal on maximal doses of...simvastatin 20 atorvastatin 20 med changed 3 (2%) simvastatin 10 atorvastatin 10 med changed 1 (0.7%) simvastatin 10 atorvastatin 20 med changed 5 (3.3
Comparative analysis of partnership behaviors in the National Park Service
Melissa S. Weddell; Brett A. Wright; Kenneth F. Backman
2008-01-01
The partnership phenomenon has received considerable attention as an alternative management strategy for public agencies. The growing use of partnerships has created a need to understand key elements of partnership success and failure, how partnerships address park and recreation management paradoxes, and guidelines for best practices (Mowen & Kerstetter, 2006)....
All-inkjet-printed thin-film transistors: manufacturing process reliability by root cause analysis.
Sowade, Enrico; Ramon, Eloi; Mitra, Kalyan Yoti; Martínez-Domingo, Carme; Pedró, Marta; Pallarès, Jofre; Loffredo, Fausta; Villani, Fulvia; Gomes, Henrique L; Terés, Lluís; Baumann, Reinhard R
2016-09-21
We report on the detailed electrical investigation of all-inkjet-printed thin-film transistor (TFT) arrays focusing on TFT failures and their origins. The TFT arrays were manufactured on flexible polymer substrates in ambient condition without the need for cleanroom environment or inert atmosphere and at a maximum temperature of 150 °C. Alternative manufacturing processes for electronic devices such as inkjet printing suffer from lower accuracy compared to traditional microelectronic manufacturing methods. Furthermore, usually printing methods do not allow the manufacturing of electronic devices with high yield (high number of functional devices). In general, the manufacturing yield is much lower compared to the established conventional manufacturing methods based on lithography. Thus, the focus of this contribution is set on a comprehensive analysis of defective TFTs printed by inkjet technology. Based on root cause analysis, we present the defects by developing failure categories and discuss the reasons for the defects. This procedure identifies failure origins and allows the optimization of the manufacturing resulting finally to a yield improvement.
Alternative RNA Splicing of CSF3R in Promoting Myelodysplastic Syndromes
2017-01-01
Myelodysplastic Syndromes, Bone Marrow Failure, Granulopoiesis, RNA splicing 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES...major distinguishing feature of myelodysplastic syndromes (MDS), the most common form of acquired bone marrow failure, is the presence of recurrent...model by expressing alternative splice form in the context of Csf3r-/- mice. KEYWORDS: Myelodysplastic Syndromes, Bone Marrow Failure
Rocket nozzle thermal shock tests in an arc heater facility
NASA Technical Reports Server (NTRS)
Painter, James H.; Williamson, Ronald A.
1986-01-01
A rocket motor nozzle thermal structural test technique that utilizes arc heated nitrogen to simulate a motor burn was developed. The technique was used to test four heavily instrumented full-scale Star 48 rocket motor 2D carbon/carbon segments at conditions simulating the predicted thermal-structural environment. All four nozzles survived the tests without catastrophic or other structural failures. The test technique demonstrated promise as a low cost, controllable alternative to rocket motor firing. The technique includes the capability of rapid termination in the event of failure, allowing post-test analysis.
ERIC Educational Resources Information Center
Carver, Priscilla Rouse; Lewis, Laurie; Tice, Peter
2010-01-01
This report provides national estimates on the availability of alternative schools and programs for students at risk of educational failure in public school districts during the 2007-08 school year. The National Center for Education Statistics (NCES) previously reported results from a similar survey of alternative schools and programs conducted…
Hao, Shengwang; Liu, Chao; Lu, Chunsheng; Elsworth, Derek
2016-06-16
A theoretical explanation of a time-to-failure relation is presented, with this relationship then used to describe the failure of materials. This provides the potential to predict timing (tf - t) immediately before failure by extrapolating the trajectory as it asymptotes to zero with no need to fit unknown exponents as previously proposed in critical power law behaviors. This generalized relation is verified by comparison with approaches to criticality for volcanic eruptions and creep failure. A new relation based on changes with stress is proposed as an alternative expression of Voight's relation, which is widely used to describe the accelerating precursory signals before material failure and broadly applied to volcanic eruptions, landslides and other phenomena. The new generalized relation reduces to Voight's relation if stress is limited to increase at a constant rate with time. This implies that the time-derivatives in Voight's analysis may be a subset of a more general expression connecting stress derivatives, and thus provides a potential method for forecasting these events.
Phadnis, Joideep; Arnold, Christine; Elmorsy, Ahmed; Flannery, Mark
2015-08-01
The redislocation rate after arthroscopic stabilization for anterior glenohumeral instability is up to 30%. The Instability Severity Index Score (ISIS) was developed to preoperatively rationalize the risk of failure, but it has not yet been validated by an independent group. To assess the utility of the ISIS in predicting failure of arthroscopic anterior shoulder stabilization and to identify other preoperative factors for failure. Case-control study; Level of evidence, 3. A case-control study was performed on 141 consecutive patients, comparing those who suffered failure of arthroscopic stabilization with those who had successful arthroscopic stabilization. The mean follow-up time was 47 months (range, 24-132 months). The ISIS was applied retrospectively, and an analysis was performed to establish independent risk factors for failure. A receiver operator coefficient curve was constructed to set a threshold ISIS for considering alternative surgery. Of 141 patients, 19 (13.5%) suffered recurrent instability. The mean ISIS of the failed stabilization group was higher than that of the successful stabilization group (5.1 vs 1.7; P < .001). Independent risk factors for failure were Hill-Sachs lesion (P < .001), glenoid bone loss (P < .001), age <21 years at the time of surgery (P < .001), age at first dislocation (P = .01), competitive-level participation in sports (P < .001), and participation in contact or overhead sports (P = .03). The presence of glenoid bone loss carried the highest risk of failure (70%). There was a 70% risk of failure if the ISIS was ≥4, as opposed to a 4% risk of failure if the ISIS was <4. This is the first completely independent study to confirm that the ISIS is a useful preoperative tool. It is recommended that surgeons consider alternative forms of stabilization if the ISIS is ≥4. © 2015 The Author(s).
Strategic rehabilitation planning of piped water networks using multi-criteria decision analysis.
Scholten, Lisa; Scheidegger, Andreas; Reichert, Peter; Maurer, Max; Mauer, Max; Lienert, Judit
2014-02-01
To overcome the difficulties of strategic asset management of water distribution networks, a pipe failure and a rehabilitation model are combined to predict the long-term performance of rehabilitation strategies. Bayesian parameter estimation is performed to calibrate the failure and replacement model based on a prior distribution inferred from three large water utilities in Switzerland. Multi-criteria decision analysis (MCDA) and scenario planning build the framework for evaluating 18 strategic rehabilitation alternatives under future uncertainty. Outcomes for three fundamental objectives (low costs, high reliability, and high intergenerational equity) are assessed. Exploitation of stochastic dominance concepts helps to identify twelve non-dominated alternatives and local sensitivity analysis of stakeholder preferences is used to rank them under four scenarios. Strategies with annual replacement of 1.5-2% of the network perform reasonably well under all scenarios. In contrast, the commonly used reactive replacement is not recommendable unless cost is the only relevant objective. Exemplified for a small Swiss water utility, this approach can readily be adapted to support strategic asset management for any utility size and based on objectives and preferences that matter to the respective decision makers. Copyright © 2013 Elsevier Ltd. All rights reserved.
Evaluation of a Linear Cumulative Damage Failure Model for Epoxy Adhesive
NASA Technical Reports Server (NTRS)
Richardson, David E.; Batista-Rodriquez, Alicia; Macon, David; Totman, Peter; McCool, Alex (Technical Monitor)
2001-01-01
Recently a significant amount of work has been conducted to provide more complex and accurate material models for use in the evaluation of adhesive bondlines. Some of this has been prompted by recent studies into the effects of residual stresses on the integrity of bondlines. Several techniques have been developed for the analysis of bondline residual stresses. Key to these analyses is the criterion that is used for predicting failure. Residual stress loading of an adhesive bondline can occur over the life of the component. For many bonded systems, this can be several years. It is impractical to directly characterize failure of adhesive bondlines under a constant load for several years. Therefore, alternative approaches for predictions of bondline failures are required. In the past, cumulative damage failure models have been developed. These models have ranged from very simple to very complex. This paper documents the generation and evaluation of some of the most simple linear damage accumulation tensile failure models for an epoxy adhesive. This paper shows how several variations on the failure model were generated and presents an evaluation of the accuracy of these failure models in predicting creep failure of the adhesive. The paper shows that a simple failure model can be generated from short-term failure data for accurate predictions of long-term adhesive performance.
Quantitative Risk Analysis on the Transport of Dangerous Goods Through a Bi-Directional Road Tunnel.
Caliendo, Ciro; De Guglielmo, Maria Luisa
2017-01-01
A quantitative risk analysis (QRA) regarding dangerous goods vehicles (DGVs) running through road tunnels was set up. Peak hourly traffic volumes (VHP), percentage of heavy goods vehicles (HGVs), and failure of the emergency ventilation system were investigated in order to assess their impact on the risk level. The risk associated with an alternative route running completely in the open air and passing through a highly populated urban area was also evaluated. The results in terms of social risk, as F/N curves, show an increased risk level with an increase the VHP, the percentage of HGVs, and a failure of the emergency ventilation system. The risk curves of the tunnel investigated were found to lie both above and below those of the alternative route running in the open air depending on the type of dangerous goods transported. In particular, risk was found to be greater in the tunnel for two fire scenarios (no explosion). In contrast, the risk level for the exposed population was found to be greater for the alternative route in three possible accident scenarios associated with explosions and toxic releases. Therefore, one should be wary before stating that for the transport of dangerous products an itinerary running completely in the open air might be used if the latter passes through a populated area. The QRA may help decisionmakers both to implement additional safety measures and to understand whether to allow, forbid, or limit circulation of DGVs. © 2016 Society for Risk Analysis.
A putative placebo analysis of the effects of LCZ696 on clinical outcomes in heart failure
McMurray, John; Packer, Milton; Desai, Akshay; Gong, Jianjian; Greenlaw, Nicola; Lefkowitz, Martin; Rizkala, Adel; Shi, Victor; Rouleau, Jean; Solomon, Scott; Swedberg, Karl; Zile, Michael R.; Andersen, Karl; Arango, Juan Luis; Arnold, Malcolm; Be˘lohlávek, Jan; Böhm, Michael; Boytsov, Sergey; Burgess, Lesley; Cabrera, Walter; Chen, Chen-Huan; Erglis, Andrejs; Fu, Michael; Gomez, Efrain; Gonzalez, Angel; Hagege, Albert-Alain; Katova, Tzvetana; Kiatchoosakun, Songsak; Kim, Kee-Sik; Bayram, Edmundo; Martinez, Felipe; Merkely, Bela; Mendoza, Iván; Mosterd, Arend; Negrusz-Kawecka, Marta; Peuhkurinen, Keijo; Ramires, Felix; Refsgaard, Jens; Senni, Michele; Sibulo, Antonio S.; Silva-Cardoso, José; Squire, Iain; Starling, Randall C.; Vinereanu, Dragos; Teerlink, John R.; Wong, Raymond
2015-01-01
Aims Although active-controlled trials with renin–angiotensin inhibitors are ethically mandated in heart failure with reduced ejection fraction, clinicians and regulators often want to know how the experimental therapy would perform compared with placebo. The angiotensin receptor-neprilysin inhibitor LCZ696 was compared with enalapril in PARADIGM-HF. We made indirect comparisons of the effects of LCZ696 with putative placebos. Methods and results We used the treatment-arm of the Studies Of Left Ventricular Dysfunction (SOLVD-T) as the reference trial for comparison of an ACE inhibitor to placebo and the Candesartan in Heart failure: Assessment of Reduction in Mortality and morbidity-Alternative trial (CHARM-Alternative) as the reference trial for comparison of an ARB to placebo. The hazard ratio of LCZ696 vs. a putative placebo was estimated through the product of the hazard ratio of LCZ696 vs. enalapril (active-control) and that of the historical active-control (enalapril or candesartan) vs. placebo. For the primary composite outcome of cardiovascular death or heart failure hospitalization in PARADIGM-HF, the relative risk reduction with LCZ696 vs. a putative placebo from SOLVD-T was 43% (95%CI 34–50%; P < 0.0001) with similarly large effects on cardiovascular death (34%, 21–44%; P < 0.0001) and heart failure hospitalization (49%, 39–58%; P < 0.0001). For all-cause mortality, the reduction compared with a putative placebo was 28% (95%CI 15–39%; P < 0.0001). Putative placebo analyses based on CHARM-Alternative gave relative risk reductions of 39% (95%CI 27–48%; P < 0.0001) for the composite outcome of cardiovascular death or heart failure hospitalization, 32% (95%CI 16–45%; P < 0.0001) for cardiovascular death, 46% (33–56%; P < 0.0001) for heart failure hospitalization, and 26% (95%CI 11–39%; P < 0.0001) for all-cause mortality. Conclusion These indirect comparisons of LCZ696 with a putative placebo show that the strategy of combined angiotensin receptor blockade and neprilysin inhibition led to striking reductions in cardiovascular and all-cause mortality, as well as heart failure hospitalization. These benefits were obtained even though LCZ696 was added to comprehensive background beta-blocker and mineralocorticoid receptor antagonist therapy. PMID:25416329
Alternative Second Language Curricula for Learners with Disabilities: Two Case Studies
ERIC Educational Resources Information Center
Abrams, Zsuzsanna
2008-01-01
According to the National Center for Learning Disabilities (2005), students with disabilities often must demonstrate failure in order to qualify for academic accommodations. For students with disabilities, this failure may be life-altering. The present article argues that alternative curricula (modified teaching and assessment plans) should be…
Derivation and experimental verification of clock synchronization theory
NASA Technical Reports Server (NTRS)
Palumbo, Daniel L.
1994-01-01
The objective of this work is to validate mathematically derived clock synchronization theories and their associated algorithms through experiment. Two theories are considered, the Interactive Convergence Clock Synchronization Algorithm and the Mid-Point Algorithm. Special clock circuitry was designed and built so that several operating conditions and failure modes (including malicious failures) could be tested. Both theories are shown to predict conservative upper bounds (i.e., measured values of clock skew were always less than the theory prediction). Insight gained during experimentation led to alternative derivations of the theories. These new theories accurately predict the clock system's behavior. It is found that a 100% penalty is paid to tolerate worst case failures. It is also shown that under optimal conditions (with minimum error and no failures) the clock skew can be as much as 3 clock ticks. Clock skew grows to 6 clock ticks when failures are present. Finally, it is concluded that one cannot rely solely on test procedures or theoretical analysis to predict worst case conditions. conditions.
Experimental validation of clock synchronization algorithms
NASA Technical Reports Server (NTRS)
Palumbo, Daniel L.; Graham, R. Lynn
1992-01-01
The objective of this work is to validate mathematically derived clock synchronization theories and their associated algorithms through experiment. Two theories are considered, the Interactive Convergence Clock Synchronization Algorithm and the Midpoint Algorithm. Special clock circuitry was designed and built so that several operating conditions and failure modes (including malicious failures) could be tested. Both theories are shown to predict conservative upper bounds (i.e., measured values of clock skew were always less than the theory prediction). Insight gained during experimentation led to alternative derivations of the theories. These new theories accurately predict the behavior of the clock system. It is found that a 100 percent penalty is paid to tolerate worst-case failures. It is also shown that under optimal conditions (with minimum error and no failures) the clock skew can be as much as three clock ticks. Clock skew grows to six clock ticks when failures are present. Finally, it is concluded that one cannot rely solely on test procedures or theoretical analysis to predict worst-case conditions.
NASA Astrophysics Data System (ADS)
Hsieh, Fu-Shiung
2011-03-01
Design of robust supervisory controllers for manufacturing systems with unreliable resources has received significant attention recently. Robustness analysis provides an alternative way to analyse a perturbed system to quickly respond to resource failures. Although we have analysed the robustness properties of several subclasses of ordinary Petri nets (PNs), analysis for non-ordinary PNs has not been done. Non-ordinary PNs have weighted arcs and have the advantage to compactly model operations requiring multiple parts or resources. In this article, we consider a class of flexible assembly/disassembly manufacturing systems and propose a non-ordinary flexible assembly/disassembly Petri net (NFADPN) model for this class of systems. As the class of flexible assembly/disassembly manufacturing systems can be regarded as the integration and interactions of a set of assembly/disassembly subprocesses, a bottom-up approach is adopted in this article to construct the NFADPN models. Due to the routing flexibility in NFADPN, there may exist different ways to accomplish the tasks. To characterise different ways to accomplish the tasks, we propose the concept of completely connected subprocesses. As long as there exists a set of completely connected subprocesses for certain type of products, the production of that type of products can still be maintained without requiring the whole NFADPN to be live. To take advantage of the alternative routes without enforcing liveness for the whole system, we generalise the concept of persistent production proposed to NFADPN. We propose a condition for persistent production based on the concept of completely connected subprocesses. We extend robustness analysis to NFADPN by exploiting its structure. We identify several patterns of resource failures and characterise the conditions to maintain operation in the presence of resource failures.
Factors Leading to Success in Diversified Occupation: A Livelihood Analysis in India
ERIC Educational Resources Information Center
Saha, Biswarup; Bahal, Ram
2015-01-01
Purpose: Livelihood diversification is a sound alternative for higher economic growth and its success or failure is conditioned by the interplay of a multitude of factors. The study of the profile of the farmers in which they operate is important to highlight the factors leading to success in diversified livelihoods. Design/Methodology/Approach: A…
Camps-Font, Octavi; Burgueño-Barris, Genís; Figueiredo, Rui; Jung, Ronald E; Gay-Escoda, Cosme; Valmaseda-Castellón, Eduard
2016-12-01
The purpose of the current study is to assess which vertical bone augmentation techniques are most effective for restoring atrophic posterior areas of the mandible with dental implants and compare these procedures with alternative treatments. Electronic literature searches in PubMed (MEDLINE), Ovid, and the Cochrane Library were conducted to identify all relevant articles published up to July 1, 2015. Eligibility was based on inclusion criteria, and quality assessments were conducted. The primary outcome variables were implant and prosthetic failure. After data extraction, meta-analyses were performed. Out of 527 potentially eligible papers, 14 randomized clinical trials were included. Out of these 14 studies, four trials assessed short implants (5 to 8 mm) as an alternative to vertical bone augmentation in sites with a residual ridge height of 5 to 8 mm. No statistically significant differences were found in implant (odds ratio [OR]: 1.02; 95% confidence interval [CI]: 0.31 to 3.31; P = 0.98; I 2 : 0%) or prosthetic failure (OR: 0.64; 95% CI: 0.21 to 1.96; P = 0.43; I 2 : 0%) after 12 months of loading. However, complications at treated sites increased with the augmentation procedures (OR: 8.33; 95% CI: 3.85 to 20.0; P <0.001; I 2 : 0%). There was no evidence of any vertical augmentation procedure being of greater benefit than any other for the primary outcomes (implant and prosthetic failure). Short implants in the posterior area of the mandible seem to be preferable to vertical augmentation procedures, which present similar implant and prosthetic failure rates but greater morbidity. All the vertical augmentation technique comparisons showed similar intergroup results.
Hao, Shengwang; Liu, Chao; Lu, Chunsheng; Elsworth, Derek
2016-01-01
A theoretical explanation of a time-to-failure relation is presented, with this relationship then used to describe the failure of materials. This provides the potential to predict timing (tf − t) immediately before failure by extrapolating the trajectory as it asymptotes to zero with no need to fit unknown exponents as previously proposed in critical power law behaviors. This generalized relation is verified by comparison with approaches to criticality for volcanic eruptions and creep failure. A new relation based on changes with stress is proposed as an alternative expression of Voight’s relation, which is widely used to describe the accelerating precursory signals before material failure and broadly applied to volcanic eruptions, landslides and other phenomena. The new generalized relation reduces to Voight’s relation if stress is limited to increase at a constant rate with time. This implies that the time-derivatives in Voight’s analysis may be a subset of a more general expression connecting stress derivatives, and thus provides a potential method for forecasting these events. PMID:27306851
CYK-4 regulates Rac, but not Rho, during cytokinesis
Zhuravlev, Yelena; Hirsch, Sophia M.; Jordan, Shawn N.; Dumont, Julien; Shirasu-Hiza, Mimi; Canman, Julie C.
2017-01-01
Cytokinesis is driven by constriction of an actomyosin contractile ring that is controlled by Rho-family small GTPases. Rho, activated by the guanine-nucleotide exchange factor ECT-2, is upstream of both myosin-II activation and diaphanous formin-mediated filamentous actin (f-actin) assembly, which drive ring constriction. The role for Rac and its regulators is more controversial, but, based on the finding that Rac inactivation can rescue cytokinesis failure when the GTPase-activating protein (GAP) CYK-4 is disrupted, Rac activity was proposed to be inhibitory to contractile ring constriction and thus specifically inactivated by CYK-4 at the division plane. An alternative model proposes that Rac inactivation generally rescues cytokinesis failure by reducing cortical tension, thus making it easier for the cell to divide when ring constriction is compromised. In this alternative model, CYK-4 was instead proposed to activate Rho by binding ECT-2. Using a combination of time-lapse in vivo single-cell analysis and Caenorhabditis elegans genetics, our evidence does not support this alternative model. First, we found that Rac disruption does not generally rescue cytokinesis failure: inhibition of Rac specifically rescues cytokinesis failure due to disruption of CYK-4 or ECT-2 but does not rescue cytokinesis failure due to disruption of two other contractile ring components, the Rho effectors diaphanous formin and myosin-II. Second, if CYK-4 regulates cytokinesis through Rho rather than Rac, then CYK-4 inhibition should decrease levels of downstream targets of Rho. Inconsistent with this, we found no change in the levels of f-actin or myosin-II at the division plane when CYK-4 GAP activity was reduced, suggesting that CYK-4 is not upstream of ECT-2/Rho activation. Instead, we found that the rescue of cytokinesis in CYK-4 mutants by Rac inactivation was Cdc42 dependent. Together our data suggest that CYK-4 GAP activity opposes Rac (and perhaps Cdc42) during cytokinesis. PMID:28298491
All-inkjet-printed thin-film transistors: manufacturing process reliability by root cause analysis
Sowade, Enrico; Ramon, Eloi; Mitra, Kalyan Yoti; Martínez-Domingo, Carme; Pedró, Marta; Pallarès, Jofre; Loffredo, Fausta; Villani, Fulvia; Gomes, Henrique L.; Terés, Lluís; Baumann, Reinhard R.
2016-01-01
We report on the detailed electrical investigation of all-inkjet-printed thin-film transistor (TFT) arrays focusing on TFT failures and their origins. The TFT arrays were manufactured on flexible polymer substrates in ambient condition without the need for cleanroom environment or inert atmosphere and at a maximum temperature of 150 °C. Alternative manufacturing processes for electronic devices such as inkjet printing suffer from lower accuracy compared to traditional microelectronic manufacturing methods. Furthermore, usually printing methods do not allow the manufacturing of electronic devices with high yield (high number of functional devices). In general, the manufacturing yield is much lower compared to the established conventional manufacturing methods based on lithography. Thus, the focus of this contribution is set on a comprehensive analysis of defective TFTs printed by inkjet technology. Based on root cause analysis, we present the defects by developing failure categories and discuss the reasons for the defects. This procedure identifies failure origins and allows the optimization of the manufacturing resulting finally to a yield improvement. PMID:27649784
Using Failure Mode and Effects Analysis to design a comfortable automotive driver seat.
Kolich, Mike
2014-07-01
Given enough time and use, all designs will fail. There are no fail-free designs. This is especially true when it comes to automotive seating comfort where the characteristics and preferences of individual customers are many and varied. To address this problem, individuals charged with automotive seating comfort development have, traditionally, relied on iterative and, as a result, expensive build-test cycles. Cost pressures being placed on today's vehicle manufacturers have necessitated the search for more efficient alternatives. This contribution aims to fill this need by proposing the application of an analytical technique common to engineering circles (but new to seating comfort development), namely Design Failure Mode and Effects Analysis (DFMEA). An example is offered to describe how development teams can use this systematic and disciplined approach to highlight potential seating comfort failure modes, reduce their risk, and bring capable designs to life. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Failure analysis in the identification of synergies between cleaning monitoring methods.
Whiteley, Greg S; Derry, Chris; Glasbey, Trevor
2015-02-01
The 4 monitoring methods used to manage the quality assurance of cleaning outcomes within health care settings are visual inspection, microbial recovery, fluorescent marker assessment, and rapid ATP bioluminometry. These methods each generate different types of information, presenting a challenge to the successful integration of monitoring results. A systematic approach to safety and quality control can be used to interrogate the known qualities of cleaning monitoring methods and provide a prospective management tool for infection control professionals. We investigated the use of failure mode and effects analysis (FMEA) for measuring failure risk arising through each cleaning monitoring method. FMEA uses existing data in a structured risk assessment tool that identifies weaknesses in products or processes. Our FMEA approach used the literature and a small experienced team to construct a series of analyses to investigate the cleaning monitoring methods in a way that minimized identified failure risks. FMEA applied to each of the cleaning monitoring methods revealed failure modes for each. The combined use of cleaning monitoring methods in sequence is preferable to their use in isolation. When these 4 cleaning monitoring methods are used in combination in a logical sequence, the failure modes noted for any 1 can be complemented by the strengths of the alternatives, thereby circumventing the risk of failure of any individual cleaning monitoring method. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
A FORTRAN program for multivariate survival analysis on the personal computer.
Mulder, P G
1988-01-01
In this paper a FORTRAN program is presented for multivariate survival or life table regression analysis in a competing risks' situation. The relevant failure rate (for example, a particular disease or mortality rate) is modelled as a log-linear function of a vector of (possibly time-dependent) explanatory variables. The explanatory variables may also include the variable time itself, which is useful for parameterizing piecewise exponential time-to-failure distributions in a Gompertz-like or Weibull-like way as a more efficient alternative to Cox's proportional hazards model. Maximum likelihood estimates of the coefficients of the log-linear relationship are obtained from the iterative Newton-Raphson method. The program runs on a personal computer under DOS; running time is quite acceptable, even for large samples.
Kilchemmann Fuentes, Carlos; Vallejos Vallejos, Carlos; Román Navarro, Andrés
Inhaled nitric oxide (iNO) is currently the first-line therapy in severe hypoxaemic respiratory failure of the newborn. Most of regional neonatal centres in Chile do not have this therapeutic alternative. To determine the cost effectiveness of inhaled nitric oxide in the treatment of respiratory failure associated with pulmonary hypertension of the newborn compared to the usual care, including the transfer to a more complex unit. A clinical decision tree was designed from the perspective of Chilean Public Health Service. Incremental cost effectiveness rates (ICER) were calculated, deterministic sensitivity analysis was performed, and probabilistic budget impact was estimated using: TreeAge Pro Healthcare 2014 software. The iNO option leads to an increase in mean cost of $ 11.7 million Chilean pesos (€15,000) per patient treated, with an ICER compared with the usual care of $23 million pesos (€30,000) in case of death or ECMO avoided. By sensitising the results by incidence, it was found that from 7 cases and upwards treated annually, inhaled nitric oxide is less costly than the transfer to a more complex unit. From the perspective of a Chilean regional hospital, incorporating inhaled nitric oxide into the management of neonatal respiratory failure is the optimal alternative in most scenarios. Copyright © 2016 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
MOMOZONO, HIROYUKI; MIYAKE, HIDEAKI; TEI, HIROMOTO; HARADA, KEN-ICHI; FUJISAWA, MASATO
2016-01-01
The present study aimed to investigate the significance of anti-androgen withdrawal and/or subsequent alternative anti-androgen therapy in patients with advanced prostate cancer (PC) who relapsed after initial maximum androgen blockade (MAB). The present study evaluated the clinical outcomes of 272 consecutive advanced PC patients undergoing anti-androgen withdrawal and/or subsequent alternative anti-androgen therapy with flutamide following the failure of initial MAB using bicalutamide. With the exception of 41 patients (15.1%) who did not undergo anti-androgen withdrawal due to the characteristics of PC suggesting aggressive diseases, prostate-specific antigen (PSA) declined from the baseline value in 83 patients (35.9%), including 18 (7.8%) with PSA decline >50%, but not in the remaining 148 (64.1%). No significant difference in the overall survival (OS) or cancer-specific survival (CSS) among the three groups was observed based on the response to anti-androgen withdrawal. Following the introduction of alternative anti-androgen therapy with flutamide, PSA decline was observed in 185 patients (68.0%), including 103 (37.9%) who achieved a PSA reduction of >50%; however, the PSA level continued to elevate in the remaining 87 (32.0%). Furthermore, of the numerous factors examined, only the duration of the initial MAB therapy was shown to be significantly correlated with the PSA decline following alternative anti-androgen therapy. Multivariate analysis of several factors identified revealed that only PSA decline following alternative anti-androgen therapy was an independent predictor of CSS and OS. If initial MAB is effective, the introduction of alternative anti-androgen therapy may be considered; however, anti-androgen withdrawal should be omitted, irrespective of the characteristics of advanced PC. PMID:27123292
Failure rate of inferior alveolar nerve block among dental students and interns
AlHindi, Maryam; Rashed, Bayan; AlOtaibi, Noura
2016-01-01
Objectives: To report the failure rate of inferior alveolar nerve block (IANB) among dental students and interns, causes of failure, investigate awareness of different IANB techniques, and to report IANB-associated complications. Methods: A 3-page questionnaire containing 13 questions was distributed to a random sample of 350 third to fifth years students and interns at the College of Dentistry, King Saud University, Riyadh, Saudi Arabia on January 2011. It included demographic questions (age, gender, and academic level) and questions on IANB failure frequency and reasons, actions taken to overcome the failure, and awareness of different anesthetic techniques, supplementary techniques, and complications. Results: Of the 250 distributed questionnaires, 238 were returned (68% response rate). Most (85.7%) of surveyed sample had experienced IANB failure once or twice. The participants attributed the failures most commonly (66.45%) to anatomical variations. The most common alternative technique used was intraligamentary injection (57.1%), although 42.8% of the sample never attempted any alternatives. Large portion of the samples stated that they either lacked both knowledge of and training for other techniques (44.9%), or that they had knowledge of them but not enough training to perform them (45.8%). Conclusion: To decrease IANB failure rates for dental students and interns, knowledge of landmarks, anatomical variation and their training in alternatives to IANB, such as the Gow-Gates and Akinosi techniques, both theoretically and clinically in the dental curriculum should be enhanced. PMID:26739980
Failure rate of inferior alveolar nerve block among dental students and interns.
AlHindi, Maryam; Rashed, Bayan; AlOtaibi, Noura
2016-01-01
To report the failure rate of inferior alveolar nerve block (IANB) among dental students and interns, causes of failure, investigate awareness of different IANB techniques, and to report IANB-associated complications. A 3-page questionnaire containing 13 questions was distributed to a random sample of 350 third to fifth years students and interns at the College of Dentistry, King Saud University, Riyadh, Saudi Arabia on January 2011. It included demographic questions (age, gender, and academic level) and questions on IANB failure frequency and reasons, actions taken to overcome the failure, and awareness of different anesthetic techniques, supplementary techniques, and complications. Of the 250 distributed questionnaires, 238 were returned (68% response rate). Most (85.7%) of surveyed sample had experienced IANB failure once or twice. The participants attributed the failures most commonly (66.45%) to anatomical variations. The most common alternative technique used was intraligamentary injection (57.1%), although 42.8% of the sample never attempted any alternatives. Large portion of the samples stated that they either lacked both knowledge of and training for other techniques (44.9%), or that they had knowledge of them but not enough training to perform them (45.8%). To decrease IANB failure rates for dental students and interns, knowledge of landmarks, anatomical variation and their training in alternatives to IANB, such as the Gow-Gates and Akinosi techniques, both theoretically and clinically in the dental curriculum should be enhanced.
Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier
2018-04-01
Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2 = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2 = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2 = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.
Damarell, Raechel A; Tieman, Jennifer J; Sladek, Ruth M
2013-07-02
PubMed translations of OvidSP Medline search filters offer searchers improved ease of access. They may also facilitate access to PubMed's unique content, including citations for the most recently published biomedical evidence. Retrieving this content requires a search strategy comprising natural language terms ('textwords'), rather than Medical Subject Headings (MeSH). We describe a reproducible methodology that uses a validated PubMed search filter translation to create a textword-only strategy to extend retrieval to PubMed's unique heart failure literature. We translated an OvidSP Medline heart failure search filter for PubMed and established version equivalence in terms of indexed literature retrieval. The PubMed version was then run within PubMed to identify citations retrieved by the filter's MeSH terms (Heart failure, Left ventricular dysfunction, and Cardiomyopathy). It was then rerun with the same MeSH terms restricted to searching on title and abstract fields (i.e. as 'textwords'). Citations retrieved by the MeSH search but not the textword search were isolated. Frequency analysis of their titles/abstracts identified natural language alternatives for those MeSH terms that performed less effectively as textwords. These terms were tested in combination to determine the best performing search string for reclaiming this 'lost set'. This string, restricted to searching on PubMed's unique content, was then combined with the validated PubMed translation to extend the filter's performance in this database. The PubMed heart failure filter retrieved 6829 citations. Of these, 834 (12%) failed to be retrieved when MeSH terms were converted to textwords. Frequency analysis of the 834 citations identified five high frequency natural language alternatives that could improve retrieval of this set (cardiac failure, cardiac resynchronization, left ventricular systolic dysfunction, left ventricular diastolic dysfunction, and LV dysfunction). Together these terms reclaimed 157/834 (18.8%) of lost citations. MeSH terms facilitate precise searching in PubMed's indexed subset. They may, however, work less effectively as search terms prior to subject indexing. A validated PubMed search filter can be used to develop a supplementary textword-only search strategy to extend retrieval to PubMed's unique content. A PubMed heart failure search filter is available on the CareSearch website (http://www.caresearch.com.au) providing access to both indexed and non-indexed heart failure evidence.
Importance Sampling in the Evaluation and Optimization of Buffered Failure Probability
2015-07-01
12th International Conference on Applications of Statistics and Probability in Civil Engineering, ICASP12 Vancouver, Canada, July 12-15, 2015...Importance Sampling in the Evaluation and Optimization of Buffered Failure Probability Marwan M. Harajli Graduate Student, Dept. of Civil and Environ...criterion is usually the failure probability . In this paper, we examine the buffered failure probability as an attractive alternative to the failure
Statistical analysis of early failures in electromigration
NASA Astrophysics Data System (ADS)
Gall, M.; Capasso, C.; Jawarani, D.; Hernandez, R.; Kawasaki, H.; Ho, P. S.
2001-07-01
The detection of early failures in electromigration (EM) and the complicated statistical nature of this important reliability phenomenon have been difficult issues to treat in the past. A satisfactory experimental approach for the detection and the statistical analysis of early failures has not yet been established. This is mainly due to the rare occurrence of early failures and difficulties in testing of large sample populations. Furthermore, experimental data on the EM behavior as a function of varying number of failure links are scarce. In this study, a technique utilizing large interconnect arrays in conjunction with the well-known Wheatstone Bridge is presented. Three types of structures with a varying number of Ti/TiN/Al(Cu)/TiN-based interconnects were used, starting from a small unit of five lines in parallel. A serial arrangement of this unit enabled testing of interconnect arrays encompassing 480 possible failure links. In addition, a Wheatstone Bridge-type wiring using four large arrays in each device enabled simultaneous testing of 1920 interconnects. In conjunction with a statistical deconvolution to the single interconnect level, the results indicate that the electromigration failure mechanism studied here follows perfect lognormal behavior down to the four sigma level. The statistical deconvolution procedure is described in detail. Over a temperature range from 155 to 200 °C, a total of more than 75 000 interconnects were tested. None of the samples have shown an indication of early, or alternate, failure mechanisms. The activation energy of the EM mechanism studied here, namely the Cu incubation time, was determined to be Q=1.08±0.05 eV. We surmise that interface diffusion of Cu along the Al(Cu) sidewalls and along the top and bottom refractory layers, coupled with grain boundary diffusion within the interconnects, constitutes the Cu incubation mechanism.
2017-03-01
little hope of a better solution, low self - esteem temporarily induced by recent failures, and difficulties in determining feasible alternatives in...The ability to think creatively and communicate potentially negative findings effectively are unique skills improved with formal training and...Homeland Security Presidential Directive IC intelligence community IED improvised explosive device JCCIC Joint Congressional Committee on
Conceptual and Preliminary Design of a Low-Cost Precision Aerial Delivery System
2016-06-01
test results. It includes an analysis of the failure modes encountered during flight experimentation , methodology used for conducting coordinate...and experimentation . Additionally, the current and desired end state of the research is addressed. Finally, this chapter outlines the methodology ...preliminary design phases are utilized to investigate and develop a potentially low-cost alternative to existing systems. Using an Agile methodology
2012-03-01
for enabling condition based maintenance plus in Army ground vehicles. The sensor study was driven from Failure Mode Effects Analysis ( FMEA ...of Tables Table 1. Sensor technology baseline study based on engine FMEA report. ...................................5 Table 2. Sensor technology...baseline study based on transmission FMEA report. .........................8 Table 3. Sensor technology baseline study based on alternator FMEA report
DDD pacemaker for severe heart failure-alternate to CRT.
Krishnamani, N C
Patients with severe systolic Heart Failure continue to have poor quality of life and increased mortality in spite of optimal medical management. Cardiac Resynchronization Therapy [CRT] is promising modality in patients with systolic heart failure and electrocardiographic [ECG] evidence of left bundle branch block [LBBB]. Cost issues continue to elude many deserving cases of this therapy in our society. Relatively cost effective Dual chamber pacing [DDD] with right atrial and isolated left ventricular pacing [RA-LV] can be a good alternative. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Chavez-Tapia, Norberto C; Mendiola-Pastrana, Indira; Ornelas-Arroyo, Victoria J; Noreña-Herrera, Camilo; Vidaña-Perez, Desiree; Delgado-Sanchez, Guadalupe; Uribe, Misael; Barrientos-Gutierrez, Tonatiuh
2015-01-01
Acute-on-chronic liver failure (ACLF) is associated with increased short and long-term mortality. Animal models of liver failure have demonstrated that granulocyte-colony stimulating factor (G-CSF) accelerates the liver regeneration process and improves survival. However, clinical evidence regarding the use of G-CSF in ACLF remains scarce. The aim of this study was to assess the benefits and harms of G-CSF in patients with acute-on-chronic liver failure. An electronic search was made in The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and LILACS up to November 2013. Randomized clinical trials comparing the use of any regimen of G-CSF against placebo or no intervention in patients with ACLF were included. Primary outcomes included overal mortality, mortality due multi-organ failure, and adverse events. Relative risk (RR) and mean difference (MD) were used. Two trials involving 102 patients were included. A significant reduction in short-term overall mortality was observed in patients receiving G-CSF compared to controls (RR 0.56; 95%CI 0.39,0.80). G-CSF failed to reduce mortality secondary to gastrointestinal bleeding (RR 1.45; 95%CI 0.50, 4.27). Adverse effects reported included: fever, rash, herpes zoster, headache and nausea. In conclusion, the use of G-CSF for the treatment of patients with ACLF significantly reduced short-term mortality. While the evidence is still limited, the apparent benefit observed on short-term mortality, mild adverse effects and lack of an alternative therapy make the use of G-CSF in ACLF patients a reasonable alternative when liver transplantation is contraindicated or unavailable.
Failed pelvic pouch substituted by continent ileostomy.
Wasmuth, H H; Tranø, G; Wibe, A; Endreseth, B H; Rydning, A; Myrvold, H E
2010-07-01
The long-term failure rate of ileal pouch-anal anastomosis (IPAA) is 10-15%. When salvage surgery is unsuccessful, most surgeons prefer pouch excision with conventional ileostomy, thus sacrificing 40-50 cm of ileum. Conversion of a pelvic pouch to a continent ileostomy (CI, Kock pouch) is an alternative that preserves both the ileal surface and pouch properties. The aim of the study was to evaluate clinical outcome after the construction of a CI following a failed IPAA. During 1984-2007, 317 patients were operated with IPAA at St Olavs Hospital and evaluated for failure, treatment and outcome. Seven patients with IPAA failure had CI. Four patients with IPAA failure referred from other hospitals underwent conversion to CI and are included in the final analysis. Seven patients had a CI constructed from the transposing pelvic pouch and four had the pelvic pouch removed and a new continent pouch constructed from the distal ileum. Median follow up after conversion to CI was 7 years (0-17 years). Two CI had to be removed due to fistulae. One patient needed a revision of the nipple valve due to pouch loosening. At the end of follow-up, 8 of the 11 patients were fully continent. One patient with Crohn's disease had minor leakage. In patients with pelvic pouch failure, the possibility of conversion to CI should be presented to the patient as an alternative to pouch excision and permanent ileostomy. The advantage is the continence and possibly a better body image. Construction of a CI on a new ileal segment may be considered, but the consequences of additional small bowel loss and risk of malnutrition if the Kock pouch fails should be appraised.
2013-01-01
Background Whereas the prognosis of second kidney transplant recipients (STR) compared to the first ones has been frequently analyzed, no study has addressed the issue of comparing the risk factor effects on graft failure between both groups. Methods Here, we propose two alternative strategies to study the heterogeneity of risk factors between two groups of patients: (i) a multiplicative-regression model for relative survival (MRS) and (ii) a stratified Cox model (SCM) specifying the graft rank as strata and assuming subvectors of the explicatives variables. These developments were motivated by the analysis of factors associated with time to graft failure (return-to-dialysis or patient death) in second kidney transplant recipients (STR) compared to the first ones. Estimation of the parameters was based on partial likelihood maximization. Monte-Carlo simulations associated with bootstrap re-sampling was performed to calculate the standard deviations for the MRS. Results We demonstrate, for the first time in renal transplantation, that: (i) male donor gender is a specific risk factor for STR, (ii) the adverse effect of recipient age is enhanced for STR and (iii) the graft failure risk related to donor age is attenuated for STR. Conclusion While the traditional Cox model did not provide original results based on the renal transplantation literature, the proposed relative and stratified models revealed new findings that are useful for clinicians. These methodologies may be of interest in other medical fields when the principal objective is the comparison of risk factors between two populations. PMID:23915191
Integrated Testing and Maintenance Technologies.
1983-12-01
provides pilot cueing for mode failures of LRU’s. Equipment fail and status indicators are lighted displays that indicate specific failures within an...provided with appropriate display cueing only when a reversion results in some loss of capability or performance. Three forms of degraded mode advisories...are- a. Reversion to an alternative data source of equivalent accuracy with no pilot cueing . b. Reversion to an alternative data source of lesser
Chen, Yun; Yang, Hui
2013-01-01
Heart rate variability (HRV) analysis has emerged as an important research topic to evaluate autonomic cardiac function. However, traditional time and frequency-domain analysis characterizes and quantify only linear and stationary phenomena. In the present investigation, we made a comparative analysis of three alternative approaches (i.e., wavelet multifractal analysis, Lyapunov exponents and multiscale entropy analysis) for quantifying nonlinear dynamics in heart rate time series. Note that these extracted nonlinear features provide information about nonlinear scaling behaviors and the complexity of cardiac systems. To evaluate the performance, we used 24-hour HRV recordings from 54 healthy subjects and 29 heart failure patients, available in PhysioNet. Three nonlinear methods are evaluated not only individually but also in combination using three classification algorithms, i.e., linear discriminate analysis, quadratic discriminate analysis and k-nearest neighbors. Experimental results show that three nonlinear methods capture nonlinear dynamics from different perspectives and the combined feature set achieves the best performance, i.e., sensitivity 97.7% and specificity 91.5%. Collectively, nonlinear HRV features are shown to have the promise to identify the disorders in autonomic cardiovascular function.
Canary in the coal mine-Initial reports of thermal injury secondary to electronic cigarettes.
Bauman, Zachary M; Roman, Jordan; Singer, Matthew; Vercruysse, Gary A
2017-05-01
The use of electronic cigarettes has become increasingly popular with claims suggesting healthier alternatives to tobacco cigarettes. However, research regarding the safety of such devices has been limited to an analysis of the inhaled vapor and the short and long-term effects on the body. A lesser recognized risk of electronic cigarette use is that of lithium-ion battery failure causing ignition, leading to severe thermal injury. Such incidents have been reported in the media but with inconsistencies from a lack of focus on the injuries sustained and a cause of ignition. The cases presented here are among the first recognized thermal injuries sustained from electronic cigarette lithium-ion battery failure, the potential rationale for these failures, and a need for increased awareness of the safety hazards of these devices. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
NASA Astrophysics Data System (ADS)
Massmann, Joel; Freeze, R. Allan
1987-02-01
This paper puts in place a risk-cost-benefit analysis for waste management facilities that explicitly recognizes the adversarial relationship that exists in a regulated market economy between the owner/operator of a waste management facility and the government regulatory agency under whose terms the facility must be licensed. The risk-cost-benefit analysis is set up from the perspective of the owner/operator. It can be used directly by the owner/operator to assess alternative design strategies. It can also be used by the regulatory agency to assess alternative regulatory policy, but only in an indirect manner, by examining the response of an owner/operator to the stimuli of various policies. The objective function is couched in terms of a discounted stream of benefits, costs, and risks over an engineering time horizon. Benefits are in the form of revenues for services provided; costs are those of construction and operation of the facility. Risk is defined as the cost associated with the probability of failure, with failure defined as the occurrence of a groundwater contamination event that violates the licensing requirements established for the facility. Failure requires a breach of the containment structure and contaminant migration through the hydrogeological environment to a compliance surface. The probability of failure can be estimated on the basis of reliability theory for the breach of containment and with a Monte-Carlo finite-element simulation for the advective contaminant transport. In the hydrogeological environment the hydraulic conductivity values are defined stochastically. The probability of failure is reduced by the presence of a monitoring network operated by the owner/operator and located between the source and the regulatory compliance surface. The level of reduction in the probability of failure depends on the probability of detection of the monitoring network, which can be calculated from the stochastic contaminant transport simulations. While the framework is quite general, the development in this paper is specifically suited for a landfill in which the primary design feature is one or more synthetic liners in parallel. Contamination is brought about by the release of a single, inorganic nonradioactive species into a saturated, high-permeability, advective, steady state horizontal flow system which can be analyzed with a two-dimensional analysis. It is possible to carry out sensitivity analyses for a wide variety of influences on this system, including landfill size, liner design, hydrogeological parameters, amount of exploration, extent of monitoring network, nature of remedial schemes, economic factors, and regulatory policy.
Ground Vehicle Condition Based Maintenance
2010-10-04
Diagnostic Process Map 32 FMEAs Developed : • Diesel Engine • Transmission • Alternators Analysis : • Identify failure modes • Derive design factors and...S&T Initiatives TARDEC P&D Process Map Component Testing ARL CBM Research AMSAA SDC & Terrain Modeling UNCLASSIFIED 3 CBM+ Overview...UNCLASSIFIED 4 RCM and CBM are core processes for CBM+ System Development • Army Regulation 750-1, 20 Sep 2007, p. 79 - Reliability Centered Maintenance (RCM
Progressive Damage and Failure Analysis of Composite Laminates
NASA Astrophysics Data System (ADS)
Joseph, Ashith P. K.
Composite materials are widely used in various industries for making structural parts due to higher strength to weight ratio, better fatigue life, corrosion resistance and material property tailorability. To fully exploit the capability of composites, it is required to know the load carrying capacity of the parts made of them. Unlike metals, composites are orthotropic in nature and fails in a complex manner under various loading conditions which makes it a hard problem to analyze. Lack of reliable and efficient failure analysis tools for composites have led industries to rely more on coupon and component level testing to estimate the design space. Due to the complex failure mechanisms, composite materials require a very large number of coupon level tests to fully characterize the behavior. This makes the entire testing process very time consuming and costly. The alternative is to use virtual testing tools which can predict the complex failure mechanisms accurately. This reduces the cost only to it's associated computational expenses making significant savings. Some of the most desired features in a virtual testing tool are - (1) Accurate representation of failure mechanism: Failure progression predicted by the virtual tool must be same as those observed in experiments. A tool has to be assessed based on the mechanisms it can capture. (2) Computational efficiency: The greatest advantages of a virtual tools are the savings in time and money and hence computational efficiency is one of the most needed features. (3) Applicability to a wide range of problems: Structural parts are subjected to a variety of loading conditions including static, dynamic and fatigue conditions. A good virtual testing tool should be able to make good predictions for all these different loading conditions. The aim of this PhD thesis is to develop a computational tool which can model the progressive failure of composite laminates under different quasi-static loading conditions. The analysis tool is validated by comparing the simulations against experiments for a selected number of quasi-static loading cases.
Risk-based decision making to manage water quality failures caused by combined sewer overflows
NASA Astrophysics Data System (ADS)
Sriwastava, A. K.; Torres-Matallana, J. A.; Tait, S.; Schellart, A.
2017-12-01
Regulatory authorities set certain environmental permit for water utilities such that the combined sewer overflows (CSO) managed by these companies conform to the regulations. These utility companies face the risk of paying penalty or negative publicity in case they breach the environmental permit. These risks can be addressed by designing appropriate solutions such as investing in additional infrastructure which improve the system capacity and reduce the impact of CSO spills. The performance of these solutions is often estimated using urban drainage models. Hence, any uncertainty in these models can have a significant effect on the decision making process. This study outlines a risk-based decision making approach to address water quality failure caused by CSO spills. A calibrated lumped urban drainage model is used to simulate CSO spill quality in Haute-Sûre catchment in Luxembourg. Uncertainty in rainfall and model parameters is propagated through Monte Carlo simulations to quantify uncertainty in the concentration of ammonia in the CSO spill. A combination of decision alternatives such as the construction of a storage tank at the CSO and the reduction in the flow contribution of catchment surfaces are selected as planning measures to avoid the water quality failure. Failure is defined as exceedance of a concentration-duration based threshold based on Austrian emission standards for ammonia (De Toffol, 2006) with a certain frequency. For each decision alternative, uncertainty quantification results into a probability distribution of the number of annual CSO spill events which exceed the threshold. For each alternative, a buffered failure probability as defined in Rockafellar & Royset (2010), is estimated. Buffered failure probability (pbf) is a conservative estimate of failure probability (pf), however, unlike failure probability, it includes information about the upper tail of the distribution. A pareto-optimal set of solutions is obtained by performing mean- pbf optimization. The effectiveness of using buffered failure probability compared to the failure probability is tested by comparing the solutions obtained by using mean-pbf and mean-pf optimizations.
Alternative Methods to Standby Gain Scheduling Following Air Data System Failure
2009-09-01
in the event of air data system failures. There are two problems with this current method. First, the pilot must take time away from other ...pertinent tasks to manually position the standby-gains via the landing gear handle, air-to-air refueling door switch or some other means. Second, the...the way, the original airspeed estimator was improved and two other alternatives to standby-gain-scheduling were investigated. Knowing what
RBFox1-mediated RNA splicing regulates cardiac hypertrophy and heart failure.
Gao, Chen; Ren, Shuxun; Lee, Jae-Hyung; Qiu, Jinsong; Chapski, Douglas J; Rau, Christoph D; Zhou, Yu; Abdellatif, Maha; Nakano, Astushi; Vondriska, Thomas M; Xiao, Xinshu; Fu, Xiang-Dong; Chen, Jau-Nian; Wang, Yibin
2016-01-01
RNA splicing is a major contributor to total transcriptome complexity; however, the functional role and regulation of splicing in heart failure remain poorly understood. Here, we used a total transcriptome profiling and bioinformatic analysis approach and identified a muscle-specific isoform of an RNA splicing regulator, RBFox1 (also known as A2BP1), as a prominent regulator of alternative RNA splicing during heart failure. Evaluation of developing murine and zebrafish hearts revealed that RBFox1 is induced during postnatal cardiac maturation. However, we found that RBFox1 is markedly diminished in failing human and mouse hearts. In a mouse model, RBFox1 deficiency in the heart promoted pressure overload-induced heart failure. We determined that RBFox1 is a potent regulator of RNA splicing and is required for a conserved splicing process of transcription factor MEF2 family members that yields different MEF2 isoforms with differential effects on cardiac hypertrophic gene expression. Finally, induction of RBFox1 expression in murine pressure overload models substantially attenuated cardiac hypertrophy and pathological manifestations. Together, this study identifies regulation of RNA splicing by RBFox1 as an important player in transcriptome reprogramming during heart failure that influence pathogenesis of the disease.
RBFox1-mediated RNA splicing regulates cardiac hypertrophy and heart failure
Gao, Chen; Ren, Shuxun; Lee, Jae-Hyung; Qiu, Jinsong; Chapski, Douglas J.; Rau, Christoph D.; Zhou, Yu; Abdellatif, Maha; Nakano, Astushi; Vondriska, Thomas M.; Xiao, Xinshu; Fu, Xiang-Dong; Chen, Jau-Nian; Wang, Yibin
2015-01-01
RNA splicing is a major contributor to total transcriptome complexity; however, the functional role and regulation of splicing in heart failure remain poorly understood. Here, we used a total transcriptome profiling and bioinformatic analysis approach and identified a muscle-specific isoform of an RNA splicing regulator, RBFox1 (also known as A2BP1), as a prominent regulator of alternative RNA splicing during heart failure. Evaluation of developing murine and zebrafish hearts revealed that RBFox1 is induced during postnatal cardiac maturation. However, we found that RBFox1 is markedly diminished in failing human and mouse hearts. In a mouse model, RBFox1 deficiency in the heart promoted pressure overload–induced heart failure. We determined that RBFox1 is a potent regulator of RNA splicing and is required for a conserved splicing process of transcription factor MEF2 family members that yields different MEF2 isoforms with differential effects on cardiac hypertrophic gene expression. Finally, induction of RBFox1 expression in murine pressure overload models substantially attenuated cardiac hypertrophy and pathological manifestations. Together, this study identifies regulation of RNA splicing by RBFox1 as an important player in transcriptome reprogramming during heart failure that influence pathogenesis of the disease. PMID:26619120
Improving the treatment planning and delivery process of Xoft electronic skin brachytherapy.
Manger, Ryan; Rahn, Douglas; Hoisak, Jeremy; Dragojević, Irena
2018-05-14
To develop an improved Xoft electronic skin brachytherapy process and identify areas of further improvement. A multidisciplinary team conducted a failure modes and effects analysis (FMEA) by developing a process map and a corresponding list of failure modes. The failure modes were scored for their occurrence, severity, and detectability, and a risk priority number (RPN) was calculated for each failure mode as the product of occurrence, severity, and detectability. Corrective actions were implemented to address the higher risk failure modes, and a revised process was generated. The RPNs of the failure modes were compared between the initial process and final process to assess the perceived benefits of the corrective actions. The final treatment process consists of 100 steps and 114 failure modes. The FMEA took approximately 20 person-hours (one physician, three physicists, and two therapists) to complete. The 10 most dangerous failure modes had RPNs ranging from 336 to 630. Corrective actions were effective at addressing most failure modes (10 riskiest RPNs ranging from 189 to 310), yet the RPNs were higher than those published for alternative systems. Many of these high-risk failure modes remained due to hardware design limitations. FMEA helps guide process improvement efforts by emphasizing the riskiest steps. Significant risks are apparent when using a Xoft treatment unit for skin brachytherapy due to hardware limitations such as the lack of several interlocks, a short source lifespan, and variability in source output. The process presented in this article is expected to reduce but not eliminate these risks. Copyright © 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background PubMed translations of OvidSP Medline search filters offer searchers improved ease of access. They may also facilitate access to PubMed’s unique content, including citations for the most recently published biomedical evidence. Retrieving this content requires a search strategy comprising natural language terms (‘textwords’), rather than Medical Subject Headings (MeSH). We describe a reproducible methodology that uses a validated PubMed search filter translation to create a textword-only strategy to extend retrieval to PubMed’s unique heart failure literature. Methods We translated an OvidSP Medline heart failure search filter for PubMed and established version equivalence in terms of indexed literature retrieval. The PubMed version was then run within PubMed to identify citations retrieved by the filter’s MeSH terms (Heart failure, Left ventricular dysfunction, and Cardiomyopathy). It was then rerun with the same MeSH terms restricted to searching on title and abstract fields (i.e. as ‘textwords’). Citations retrieved by the MeSH search but not the textword search were isolated. Frequency analysis of their titles/abstracts identified natural language alternatives for those MeSH terms that performed less effectively as textwords. These terms were tested in combination to determine the best performing search string for reclaiming this ‘lost set’. This string, restricted to searching on PubMed’s unique content, was then combined with the validated PubMed translation to extend the filter’s performance in this database. Results The PubMed heart failure filter retrieved 6829 citations. Of these, 834 (12%) failed to be retrieved when MeSH terms were converted to textwords. Frequency analysis of the 834 citations identified five high frequency natural language alternatives that could improve retrieval of this set (cardiac failure, cardiac resynchronization, left ventricular systolic dysfunction, left ventricular diastolic dysfunction, and LV dysfunction). Together these terms reclaimed 157/834 (18.8%) of lost citations. Conclusions MeSH terms facilitate precise searching in PubMed’s indexed subset. They may, however, work less effectively as search terms prior to subject indexing. A validated PubMed search filter can be used to develop a supplementary textword-only search strategy to extend retrieval to PubMed’s unique content. A PubMed heart failure search filter is available on the CareSearch website (http://www.caresearch.com.au) providing access to both indexed and non-indexed heart failure evidence. PMID:23819658
Bruxism and Dental Implants: A Meta-Analysis.
Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann
2015-10-01
To test the null hypothesis of no difference in the implant failure rates, postoperative infection, and marginal bone loss after the insertion of dental implants in bruxers compared with the insertion in non-bruxers against the alternative hypothesis of a difference. An electronic search was undertaken in June 2014. Eligibility criteria included clinical studies, either randomized or not. Ten publications were included with a total of 760 implants inserted in bruxers (49 failures; 6.45%) and 2989 in non-bruxers (109 failures; 3.65%). Due to lack of information, meta-analyses for the outcomes "postoperative infection" and "marginal bone loss" were not possible. A risk ratio of 2.93 was found (95% confidence interval, 1.48-5.81; P = 0.002). These results cannot suggest that the insertion of dental implants in bruxers affects the implant failure rates due to a limited number of published studies, all characterized by a low level of specificity, and most of them deal with a limited number of cases without a control group. Therefore, the real effect of bruxing habits on the osseointegration and survival of endosteal dental implants is still not well established.
NASA Technical Reports Server (NTRS)
Brichenough, A. G.
1975-01-01
The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.
A closer look: Alternative pain management practices by heart failure patients with chronic pain.
McDonald, Deborah Dillon; Soutar, Christina; Chan, Maria Agudelo; Afriyie, Angela
2015-01-01
To describe alternative non-pharmaceutical non-nutraceutical pain self-management strategies used by people with heart failure (HF) in order to reduce chronic non-cardiac pain. Little is known about alternative pain self-treatments used by HF patients with chronic pain. A cross-sectional descriptive design was used with 25 hospitalized HF patients who had chronic pain and used at least one alternative pain treatment. Pain intensity, pain interference with function, and current pain treatments were measured with the Brief Pain Inventory. Alternative treatments included walking, stretching, use of heat and cold. Five patients used evidence-based pain treatments for their chronic pain conditions. Patients reported moderate pain intensity and pain interference with activity. Patients with HF and chronic pain use few alternative pain treatments. Screening for chronic pain and referral to Integrative Medicine and/or Palliative care for a pain management consult might reduce the added burden of pain in people with HF. Copyright © 2015 Elsevier Inc. All rights reserved.
Calvert, George T; Cummings, Judd E; Bowles, Austin J; Jones, Kevin B; Wurtz, L Daniel; Randall, R Lor
2014-03-01
Aseptic failure of massive endoprostheses used in the reconstruction of major skeletal defects remains a major clinical problem. Fixation using compressive osseointegration was developed as an alternative to cemented and traditional press-fit fixation in an effort to decrease aseptic failure rates. The purpose of this study was to answer the following questions: (1) What is the survivorship of this technique at minimum 2-year followup? (2) Were patient demographic variables (age, sex) or anatomic location associated with implant failure? (3) Were there any prosthesis-related variables (eg, spindle size) associated with failure? (4) Was there a discernible learning curve associated with the use of the new device as defined by a difference in failure rate early in the series versus later on? The first 50 cases using compressive osseointegration fixation from two tertiary referral centers were retrospectively studied. Rates of component removal for any reason and for aseptic failure were calculated. Demographic, surgical, and oncologic factors were analyzed using regression analysis to assess for association with implant failure. Minimum followup was 2 years with a mean of 66 months. Median age at the time of surgery was 14.5 years. A total of 15 (30%) implants were removed for any reason. Of these revisions, seven (14%) were the result of aseptic failure. Five of the seven aseptic failures occurred at less than 1 year (average, 8.3 months), and none occurred beyond 17 months. With the limited numbers available, no demographic, surgical, or prosthesis-related factors correlated with failure. Most aseptic failures of compressive osseointegration occurred early. Longer followup is needed to determine if this technique is superior to other forms of fixation.
Effect of Crystal Orientation on Analysis of Single-Crystal, Nickel-Based Turbine Blade Superalloys
NASA Technical Reports Server (NTRS)
Swanson, G. R.; Arakere, N. K.
2000-01-01
High-cycle fatigue-induced failures in turbine and turbopump blades is a pervasive problem. Single-crystal nickel turbine blades are used because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities. Single-crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant and complicating factor. A fatigue failure criterion based on the maximum shear stress amplitude on the 24 octahedral and 6 cube slip systems is presented for single-crystal nickel superalloys (FCC crystal). This criterion greatly reduces the scatter in uniaxial fatigue data for PWA 1493 at 1,200 F in air. Additionally, single-crystal turbine blades used in the Space Shuttle main engine high pressure fuel turbopump/alternate turbopump are modeled using a three-dimensional finite element (FE) model. This model accounts for material orthotrophy and crystal orientation. Fatigue life of the blade tip is computed using FE stress results and the failure criterion that was developed. Stress analysis results in the blade attachment region are also presented. Results demonstrate that control of crystallographic orientation has the potential to significantly increase a component's resistance to fatigue crack growth without adding additional weight or cost.
NASA Technical Reports Server (NTRS)
Kelly, Michael J.
2013-01-01
The Alternative Fuel Effects on Contrails & Cruise Emissions (ACCESS) Project Integration Manager requested in July 2012 that the NASA Engineering and Safety Center (NESC) form a team to independently assess aircraft structural failure hazards associated with the ACCESS experiment and to identify potential flight test hazard mitigations to ensure flight safety. The ACCESS Project Integration Manager subsequently requested that the assessment scope be focused predominantly on structural failure risks to the aircraft empennage raft empennage.
Forensic analysis of rockfall scars
NASA Astrophysics Data System (ADS)
de Vilder, Saskia J.; Rosser, Nick J.; Brain, Matthew J.
2017-10-01
We characterise and analyse the detachment (scar) surfaces of rockfalls to understand the mechanisms that underpin their failure. Rockfall scars are variously weathered and comprised of both discontinuity release surfaces and surfaces indicative of fracturing through zones of previously intact rock, known as rock bridges. The presence of rock bridges and pre-existing discontinuities is challenging to quantify due to the difficulty in determining discontinuity persistence below the surface of a rock slope. Rock bridges form an important control in holding blocks onto rockslopes, with their frequency, extent and location commonly modelled from the surface exposure of daylighting discontinuities. We explore an alternative approach to assessing their role, by characterising failure scars. We analyse a database of multiple rockfall scar surfaces detailing the areal extent, shape, and location of broken rock bridges and weathered surfaces. Terrestrial laser scanning and gigapixel imagery were combined to record the detailed texture and surface morphology. From this, scar surfaces were mapped via automated classification based on RGB pixel values. Our analysis of the resulting data from scars on the North Yorkshire coast (UK) indicates a wide variation in both weathering and rock bridge properties, controlled by lithology and associated rock mass structure. Importantly, the proportion of rock bridges in a rockfall failure surface does not increase with failure size. Rather larger failures display fracturing through multiple rock bridges, and in contrast smaller failures fracture occurs only through a single critical rock bridge. This holds implications for how failure mechanisms change with rockfall size and shape. Additionally, the location of rock bridges with respect to the geometry of an incipient rockfall is shown to determine failure mode. Weathering can occur both along discontinuity surfaces and previously broken rock bridges, indicating the sequential stages of progressively detaching rockfall. Our findings have wider implications for hazard assessment where rock slope stability is dependent on the nature of rock bridges, how this is accounted for in slope stability modelling, and the implications of rock bridges on long-term rock slope evolution.
Reliability Analysis of a Green Roof Under Different Storm Scenarios
NASA Astrophysics Data System (ADS)
William, R. K.; Stillwell, A. S.
2015-12-01
Urban environments continue to face the challenges of localized flooding and decreased water quality brought on by the increasing amount of impervious area in the built environment. Green infrastructure provides an alternative to conventional storm sewer design by using natural processes to filter and store stormwater at its source. However, there are currently few consistent standards available in North America to ensure that installed green infrastructure is performing as expected. This analysis offers a method for characterizing green roof failure using a visual aid commonly used in earthquake engineering: fragility curves. We adapted the concept of the fragility curve based on the efficiency in runoff reduction provided by a green roof compared to a conventional roof under different storm scenarios. We then used the 2D distributed surface water-groundwater coupled model MIKE SHE to model the impact that a real green roof might have on runoff in different storm events. We then employed a multiple regression analysis to generate an algebraic demand model that was input into the Matlab-based reliability analysis model FERUM, which was then used to calculate the probability of failure. The use of reliability analysis as a part of green infrastructure design code can provide insights into green roof weaknesses and areas for improvement. It also supports the design of code that is more resilient than current standards and is easily testable for failure. Finally, the understanding of reliability of a single green roof module under different scenarios can support holistic testing of system reliability.
Thorndahl, S; Willems, P
2008-01-01
Failure of urban drainage systems may occur due to surcharge or flooding at specific manholes in the system, or due to overflows from combined sewer systems to receiving waters. To quantify the probability or return period of failure, standard approaches make use of the simulation of design storms or long historical rainfall series in a hydrodynamic model of the urban drainage system. In this paper, an alternative probabilistic method is investigated: the first-order reliability method (FORM). To apply this method, a long rainfall time series was divided in rainstorms (rain events), and each rainstorm conceptualized to a synthetic rainfall hyetograph by a Gaussian shape with the parameters rainstorm depth, duration and peak intensity. Probability distributions were calibrated for these three parameters and used on the basis of the failure probability estimation, together with a hydrodynamic simulation model to determine the failure conditions for each set of parameters. The method takes into account the uncertainties involved in the rainstorm parameterization. Comparison is made between the failure probability results of the FORM method, the standard method using long-term simulations and alternative methods based on random sampling (Monte Carlo direct sampling and importance sampling). It is concluded that without crucial influence on the modelling accuracy, the FORM is very applicable as an alternative to traditional long-term simulations of urban drainage systems.
Slip initiation in alternative and slip-resistant footwear.
Chander, Harish; Wade, Chip; Garner, John C; Knight, Adam C
2017-12-01
Slips occur as a result of failure of normal locomotion. The purpose of this study is to analyze the impact of alternative footwear (Crocs™, flip-flops) and an industry standard low-top slip-resistant shoe (SRS) under multiple gait trials (normal dry, unexpected slip, alert slip and expected slip) on lower extremity joint kinematics, kinetics and muscle activity. Eighteen healthy male participants (age: 22.28 ± 2.2 years; height: 177.66 ± 6.9 cm; mass: 79.27 ± 7.6 kg) completed the study. Kinematic, kinetic and muscle activity variables were analyzed using a 3(footwear) × 4(gait trials) repeated-measures analysis of variance at p = 0.05. Greater plantar flexion angles, lower ground reaction forces and greater muscle activity were seen on slip trials with the alternative footwear. During slip events, SRS closely resembled normal dry biomechanics, suggesting it to be a safer footwear choice compared with alternative footwear.
Karvetski, Christopher W; Lambert, James H; Linkov, Igor
2011-04-01
Military and industrial facilities need secure and reliable power generation. Grid outages can result in cascading infrastructure failures as well as security breaches and should be avoided. Adding redundancy and increasing reliability can require additional environmental, financial, logistical, and other considerations and resources. Uncertain scenarios consisting of emergent environmental conditions, regulatory changes, growth of regional energy demands, and other concerns result in further complications. Decisions on selecting energy alternatives are made on an ad hoc basis. The present work integrates scenario analysis and multiple criteria decision analysis (MCDA) to identify combinations of impactful emergent conditions and to perform a preliminary benefits analysis of energy and environmental security investments for industrial and military installations. Application of a traditional MCDA approach would require significant stakeholder elicitations under multiple uncertain scenarios. The approach proposed in this study develops and iteratively adjusts a scoring function for investment alternatives to find the scenarios with the most significant impacts on installation security. A robust prioritization of investment alternatives can be achieved by integrating stakeholder preferences and focusing modeling and decision-analytical tools on a few key emergent conditions and scenarios. The approach is described and demonstrated for a campus of several dozen interconnected industrial buildings within a major installation. Copyright © 2010 SETAC.
Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin
2016-09-01
Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Probability of Failure Analysis Standards and Guidelines for Expendable Launch Vehicles
NASA Astrophysics Data System (ADS)
Wilde, Paul D.; Morse, Elisabeth L.; Rosati, Paul; Cather, Corey
2013-09-01
Recognizing the central importance of probability of failure estimates to ensuring public safety for launches, the Federal Aviation Administration (FAA), Office of Commercial Space Transportation (AST), the National Aeronautics and Space Administration (NASA), and U.S. Air Force (USAF), through the Common Standards Working Group (CSWG), developed a guide for conducting valid probability of failure (POF) analyses for expendable launch vehicles (ELV), with an emphasis on POF analysis for new ELVs. A probability of failure analysis for an ELV produces estimates of the likelihood of occurrence of potentially hazardous events, which are critical inputs to launch risk analysis of debris, toxic, or explosive hazards. This guide is intended to document a framework for POF analyses commonly accepted in the US, and should be useful to anyone who performs or evaluates launch risk analyses for new ELVs. The CSWG guidelines provide performance standards and definitions of key terms, and are being revised to address allocation to flight times and vehicle response modes. The POF performance standard allows a launch operator to employ alternative, potentially innovative methodologies so long as the results satisfy the performance standard. Current POF analysis practice at US ranges includes multiple methodologies described in the guidelines as accepted methods, but not necessarily the only methods available to demonstrate compliance with the performance standard. The guidelines include illustrative examples for each POF analysis method, which are intended to illustrate an acceptable level of fidelity for ELV POF analyses used to ensure public safety. The focus is on providing guiding principles rather than "recipe lists." Independent reviews of these guidelines were performed to assess their logic, completeness, accuracy, self- consistency, consistency with risk analysis practices, use of available information, and ease of applicability. The independent reviews confirmed the general validity of the performance standard approach and suggested potential updates to improve the accuracy each of the example methods, especially to address reliability growth.
Intelligent failure-tolerant control
NASA Technical Reports Server (NTRS)
Stengel, Robert F.
1991-01-01
An overview of failure-tolerant control is presented, beginning with robust control, progressing through parallel and analytical redundancy, and ending with rule-based systems and artificial neural networks. By design or implementation, failure-tolerant control systems are 'intelligent' systems. All failure-tolerant systems require some degrees of robustness to protect against catastrophic failure; failure tolerance often can be improved by adaptivity in decision-making and control, as well as by redundancy in measurement and actuation. Reliability, maintainability, and survivability can be enhanced by failure tolerance, although each objective poses different goals for control system design. Artificial intelligence concepts are helpful for integrating and codifying failure-tolerant control systems, not as alternatives but as adjuncts to conventional design methods.
1999-03-01
expressed in this thesis are those of the author and do not reflect the official policy or position of the Department of Defense or the U.S...a satellite constellation through a policy of launching a new satellite at the first on-orbit failure. Increasing satellite design life is a common...alternatives consisted of the current constellation with the addition of various servicing architectures. We assumed no radical shift in GPS management policy
Sancho, Leyla Gomes; Dain, Sulamis
2008-06-01
This study aims to contribute to the discussion on the possibility of applying health economics assessment, specifically the cost-effectiveness technique, to renal replacement therapies for end-stage renal failure. A review was conducted on the interventions and their alternative courses from the perspective of the various methodological proposals in the literature, considering the availability of data and information in Brazil to back this type of research.
Ruh, Christine A; Parameswaran, Ganapathi I; Wojciechowski, Amy L; Mergenhagen, Kari A
2015-11-01
The use of outpatient parenteral antibiotic therapy (OPAT) programs has become more frequent because of benefits in costs with equivalent clinical outcomes compared with inpatient care. The purpose of this study was to evaluate the outcomes of our program. A modified pharmacoeconomic analysis was performed to compare costs of our program with hospital or rehabilitation facility care. This was a retrospective chart review of 96 courses of OPAT between April 1, 2011, and July 31, 2013. Clinical failures were defined as readmission or death due to worsening infection or readmission secondary to adverse drug event (ADE) to antibiotic therapy. This does not include those patients readmitted for reasons not associated with OPAT therapy, including comorbidities or elective procedures. Baseline characteristics and program-specific data were analyzed. Statistically significant variables were built into a multivariate logistic regression model to determine predictors of failure. A pharmacoeconomic analysis was performed with the use of billing records. Of the total episodes evaluated, 17 (17.71%) clinically failed therapy, and 79 (82.29%) were considered a success. In the multivariate analysis, number of laboratory draws (P = 0.02) and occurrence of drug reaction were significant in the final model, P = 0.02 and P = 0.001, respectively. The presence an adverse drug reaction increases the odds of failure (OR = 10.10; 95% CI, 2.69-44.90). Compared with inpatient or rehabilitation care, the cost savings was $6,932,552.03 or $2,649,870.68, respectively. In our study, patients tolerated OPAT well, with a low number of failures due to ADE. The clinical outcomes and cost savings of our program indicate that OPAT can be a viable alternative to long-term inpatient antimicrobial therapy. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Zolkoski, Staci M.; Bullock, Lyndal M.; Gable, Robert A.
2016-01-01
Many students with emotional and behavioral disorders placed in alternative education settings lack resilience and are likely to experience failure in school and beyond without carefully designed intervention programs. Although researchers have examined both resilience in children and youth and their placement in alternative education settings,…
Sub-Optimal Choice by Pigeons: Failure to Support the Allais Paradox
ERIC Educational Resources Information Center
Zentall, Thomas R.; Stagner, Jessica P.
2011-01-01
Pigeons show a preference for an alternative that provides them with discriminative stimuli (sometimes a stimulus that predicts reinforcement and at other times a stimulus that predicts the absence of reinforcement) over an alternative that provides them with nondiscriminative stimuli, even if the nondiscriminative stimulus alternative is…
Kurji, Zahra A; Sigal, Michael J; Andrews, Paul; Titley, Keith
2011-01-01
The purpose of this study was to assess the clinical and radiographic outcomes of a 1-minute application of full-strength Buckley's formocresol with concurrent hemostasis using the medicated cotton pledget in human primary teeth. Using a retrospective chart review, clinical and radiographic data were available for 557 primary molars in 320 patients. Descriptive statistics and survival analysis were used to assess outcomes. Overall clinical success, radiographic success, and cumulative 5-year survival rates were approximately 99%, 90%, and 87%, respectively. Internal root resorption (∼5%) and pulp canal obliteration (∼2%) were the most frequently observed radiographic failures. Thirty-nine teeth were extracted due to clinical and or radiographic failure. Mandibular molars were 6 times more prone to radiographic failure than maxillary molars. Success rates for the modified technique are comparable to techniques that use the 5-minute diluted or full-strength solutions reported in the literature. This 1-minute full-strength formocresol technique is an acceptable alternative to published traditional techniques.
Jaarsma, Tiny; Nikolova-Simons, Mariana; van der Wal, Martje H L
2012-01-01
Despite an increasing body of knowledge on self-care in heart failure patients, the need for effective interventions remains. We sought to deepen the understanding of interventions that heart failure nurses use in clinical practice to improve patient adherence to medication and symptom monitoring. A qualitative study with a directed content analysis was performed, using data from a selected sample of Dutch-speaking heart failure nurses who completed booklets with two vignettes involving medication adherence and symptom recognition. Nurses regularly assess and reassess patients before they decide on an intervention. They evaluate basic/factual information and barriers in a patient's behavior, and try to find room for improvement in a patient's behavior. Interventions that heart failure nurses use to improve adherence to medication and symptom monitoring were grouped into the themes of increasing knowledge, increasing motivation, and providing patients with practical tools. Nurses also described using technology-based tools, increased social support, alternative communication, partnership approaches, and coordination of care to improve adherence to medications and symptom monitoring. Despite a strong focus on educational strategies, nurses also reported other strategies to increase patient adherence. Nurses use several strategies to improve patient adherence that are not incorporated into guidelines. These interventions need to be evaluated for further applications in improving heart failure management. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pickett, Leon, Jr.
Past research has conclusively shown that long fiber structural composites possess superior specific energy absorption characteristics as compared to steel and aluminum structures. However, destructive physical testing of composites is very costly and time consuming. As a result, numerical solutions are desirable as an alternative to experimental testing. Up until this point, very little numerical work has been successful in predicting the energy absorption of composite crush structures. This research investigates the ability to use commercially available numerical modeling tools to approximate the energy absorption capability of long-fiber composite crush tubes. This study is significant because it provides a preliminary analysis of the suitability of LS-DYNA to numerically characterize the crushing behavior of a dynamic axial impact crushing event. Composite crushing theory suggests that there are several crushing mechanisms occurring during a composite crush event. This research evaluates the capability and suitability of employing, LS-DYNA, to simulate the dynamic crush event of an E-glass/epoxy cylindrical tube. The model employed is the composite "progressive failure model", a much more limited failure model when compared to the experimental failure events which naturally occur. This numerical model employs (1) matrix cracking, (2) compression, and (3) fiber breakage failure modes only. The motivation for the work comes from the need to reduce the significant cost associated with experimental trials. This research chronicles some preliminary efforts to better understand the mechanics essential in pursuit of this goal. The immediate goal is to begin to provide deeper understanding of a composite crush event and ultimately create a viable alternative to destructive testing of composite crush tubes.
Aquatic exercise training and stable heart failure: A systematic review and meta-analysis.
Adsett, Julie A; Mudge, Alison M; Morris, Norman; Kuys, Suzanne; Paratz, Jennifer D
2015-01-01
A meta-analysis and review of the evidence was conducted to determine the efficacy of aquatic exercise training for individuals with heart failure compared to traditional land-based programmes. A systematic search was conducted for studies published prior to March 2014, using MEDLINE, PUBMED, Cochrane Library, CINAHL and PEDro databases. Key words and synonyms relating to aquatic exercise and heart failure comprised the search strategy. Interventions included aquatic exercise or a combination of aquatic plus land-based training, whilst comparator protocols included usual care, no exercise or land-based training alone. The primary outcome of interest was exercise performance. Studies reporting on muscle strength, quality of life and a range of haemodynamic and physiological parameters were also reviewed. Eight studies met criteria, accounting for 156 participants. Meta-analysis identified studies including aquatic exercise to be superior to comparator protocols for 6 minute walk test (p < 0.004) and peak power (p < 0.044). Compared to land-based training programmes, aquatic exercise training provided similar benefits for VO(2peak), muscle strength and quality of life, though was not superior. Cardiac dimensions, left ventricular ejection fraction, cardiac output and BNP were not influenced by aquatic exercise training. For those with stable heart failure, aquatic exercise training can improve exercise capacity, muscle strength and quality of life similar to land-based training programmes. This form of exercise may provide a safe and effective alternative for those unable to participate in traditional exercise programmes. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.
Grau, S; Rebollo, P; Cuervo, J; Gil-Parrado, S
2011-09-01
To assess the efficiency of daptomycin as firstline therapy (D) versus daptomycin as salvage therapy after vancomycin (V→D ) or linezolid (L→D) failure in gram-positive bacteraemia and complicated skin and skin-structure infections (cSSTIs). Cost-effectiveness analysis of 161 bacteraemia and 84 cSSTIs patients comparing the above mentioned therapeutic alternatives was performed using the data from 27 Spanish hospitals involved in the EUCORE study. Direct medical costs were considered. Patients were observed from the first antibiotic dose for infection until either the end of daptomycin therapy or exitus. A multivariate Monte Carlo probabilistic sensitivity analysis was applied for costs (lognormal distribution) and effectiveness (normal distribution). In terms of effectiveness there were no statistical differences between groups but referring total costs per patient, there were significant differences. Sensitivity analysis confirmed that D dominates over L→D between 44.2%-62.1% of simulations in bacteraemia and between 48.2%-67.5% in cSSTIs. In comparison to V→D, D dominance was detected in 29.2%-33.2% of simulations in bacteraemia and between 48.2%-59.3% in cSSTIs. Daptomycin as first-line therapy dominates over daptomycin as salvage therapy after linezolid failure both in bacteraemia and cSSTIs. Comparing daptomycin as first-line therapy with its use after vancomycin failure, in cSSTIs the former is dominant. In bacteremia daptomycin as first line therapy is as effective as daptomycin as salvage therapy after vancomycin failure and implies lower costs.
NASA Astrophysics Data System (ADS)
Meade, Brendan J.; DeVries, Phoebe M. R.; Faller, Jeremy; Viegas, Fernanda; Wattenberg, Martin
2017-11-01
Aftershocks may be triggered by the stresses generated by preceding mainshocks. The temporal frequency and maximum size of aftershocks are well described by the empirical Omori and Bath laws, but spatial patterns are more difficult to forecast. Coulomb failure stress is perhaps the most common criterion invoked to explain spatial distributions of aftershocks. Here we consider the spatial relationship between patterns of aftershocks and a comprehensive list of 38 static elastic scalar metrics of stress (including stress tensor invariants, maximum shear stress, and Coulomb failure stress) from 213 coseismic slip distributions worldwide. The rates of true-positive and false-positive classification of regions with and without aftershocks are assessed with receiver operating characteristic analysis. We infer that the stress metrics that are most consistent with observed aftershock locations are maximum shear stress and the magnitude of the second and third invariants of the stress tensor. These metrics are significantly better than random assignment at a significance level of 0.005 in over 80% of the slip distributions. In contrast, the widely used Coulomb failure stress criterion is distinguishable from random assignment in only 51-64% of the slip distributions. These results suggest that a number of alternative scalar metrics are better predictors of aftershock locations than classic Coulomb failure stress change.
Simulation and Failure Analysis of Car Bumper Made of Pineapple Leaf Fiber Reinforced Composite
NASA Astrophysics Data System (ADS)
Arbintarso, E. S.; Muslim, M.; Rusianto, T.
2018-02-01
The bumper car made of the Pineapple Leaf Fiber Reinforced Composite (PLFRC) is possible to be produced with the advantage of easy to get, and cheap. Pineapple leaf fiber has chosen as a natural fiber, which the maximum of the strength of 368 MPa. The objective of this study was to determine the maximum capability of front car bumpers using Pineapple Leaf Fiber Reinforced Composite materials through the process of simulating stress analysis with Solidworks 2014 software. The aim also to know the distribution of loads that occur on the front car bumper and predict the critical point position on the design of the bumper. The result will use to develop the alternative lightweight, cheap and environmentally friendly materials in general and the development of the use of pineapple fiber for automotive purposes in particular. Simulations and failure analysis have been conducted and showed an increased impact speed in line with increased displacement, strain, and stress that occur on the surface of the bumper. The bumper can withstand collisions at a speed of less than 70 kph.
46 CFR 62.25-10 - Manual alternate control systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... automatic primary control system failure; (2) Be suitable for manual control for prolonged periods; (3) Be... 46 Shipping 2 2011-10-01 2011-10-01 false Manual alternate control systems. 62.25-10 Section 62.25... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-10 Manual alternate control systems...
The Positive Alternative Credit Experience (PACE) Program a Quantitative Comparative Study
ERIC Educational Resources Information Center
Warren, Rebecca Anne
2011-01-01
The purpose of this quantitative comparative study was to evaluate the Positive Alternative Credit Experience (PACE) Program using an objectives-oriented approach to a formative program evaluation. The PACE Program was a semester-long high school alternative education program designed to serve students at-risk for academic failure or dropping out…
Adaptive subdomain modeling: A multi-analysis technique for ocean circulation models
NASA Astrophysics Data System (ADS)
Altuntas, Alper; Baugh, John
2017-07-01
Many coastal and ocean processes of interest operate over large temporal and geographical scales and require a substantial amount of computational resources, particularly when engineering design and failure scenarios are also considered. This study presents an adaptive multi-analysis technique that improves the efficiency of these computations when multiple alternatives are being simulated. The technique, called adaptive subdomain modeling, concurrently analyzes any number of child domains, with each instance corresponding to a unique design or failure scenario, in addition to a full-scale parent domain providing the boundary conditions for its children. To contain the altered hydrodynamics originating from the modifications, the spatial extent of each child domain is adaptively adjusted during runtime depending on the response of the model. The technique is incorporated in ADCIRC++, a re-implementation of the popular ADCIRC ocean circulation model with an updated software architecture designed to facilitate this adaptive behavior and to utilize concurrent executions of multiple domains. The results of our case studies confirm that the method substantially reduces computational effort while maintaining accuracy.
NASA Astrophysics Data System (ADS)
Gaulke, Linda S.; Weiyang, Xiao; Scanlon, Andrew; Henck, Amanda; Hinckley, Tom
2010-01-01
The administration of Jiuzhaigou National Park in Sichuan Province, China, is in the process of considering a range of upgrades to their sanitation and wastewater treatment systems. Their case history involves an ongoing series of engineering design flaws and management failures. The administration of the Park identified sustainability, environmental protection, and education goals for their sanitation and wastewater treatment system. To meet the goal of sustainability, environmental and economic concerns of the Park’s administration had to be balanced with socio-cultural needs. An advanced reconnaissance method was developed that identified reasons for previous failures, conducted stakeholder analysis and interviews, determined evaluation criteria, and introduced innovative alternatives with records of successful global implementations. This evaluation also helped the Park to better define their goals . To prevent future failures, the administration of the Park must commit to a balanced and thorough evaluation process for selection of a final alternative and institute effective long-term management and monitoring of systems. In addition, to meet goals and achieve energy efficient, cost-effective use of resources, the Park must shift their thinking from one of waste disposal to resource recovery. The method and criteria developed for this case study provides a framework to aid in the successful implementation of sanitation projects in both underdeveloped and developed areas of the world, incorporating socio-cultural values and resource recovery for a complex group of stakeholders.
Markov and semi-Markov processes as a failure rate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabski, Franciszek
2016-06-08
In this paper the reliability function is defined by the stochastic failure rate process with a non negative and right continuous trajectories. Equations for the conditional reliability functions of an object, under assumption that the failure rate is a semi-Markov process with an at most countable state space are derived. A proper theorem is presented. The linear systems of equations for the appropriate Laplace transforms allow to find the reliability functions for the alternating, the Poisson and the Furry-Yule failure rate processes.
Multi-criteria robustness analysis of metro networks
NASA Astrophysics Data System (ADS)
Wang, Xiangrong; Koç, Yakup; Derrible, Sybil; Ahmad, Sk Nasir; Pino, Willem J. A.; Kooij, Robert E.
2017-05-01
Metros (heavy rail transit systems) are integral parts of urban transportation systems. Failures in their operations can have serious impacts on urban mobility, and measuring their robustness is therefore critical. Moreover, as physical networks, metros can be viewed as topological entities, and as such they possess measurable network properties. In this article, by using network science and graph theory, we investigate ten theoretical and four numerical robustness metrics and their performance in quantifying the robustness of 33 metro networks under random failures or targeted attacks. We find that the ten theoretical metrics capture two distinct aspects of robustness of metro networks. First, several metrics place an emphasis on alternative paths. Second, other metrics place an emphasis on the length of the paths. To account for all aspects, we standardize all ten indicators and plot them on radar diagrams to assess the overall robustness for metro networks. Overall, we find that Tokyo and Rome are the most robust networks. Rome benefits from short transferring and Tokyo has a significant number of transfer stations, both in the city center and in the peripheral area of the city, promoting both a higher number of alternative paths and overall relatively short path-lengths.
Fatigue Failure of Space Shuttle Main Engine Turbine Blades
NASA Technical Reports Server (NTRS)
Swanson, Gregrory R.; Arakere, Nagaraj K.
2000-01-01
Experimental validation of finite element modeling of single crystal turbine blades is presented. Experimental results from uniaxial high cycle fatigue (HCF) test specimens and full scale Space Shuttle Main Engine test firings with the High Pressure Fuel Turbopump Alternate Turbopump (HPFTP/AT) provide the data used for the validation. The conclusions show the significant contribution of the crystal orientation within the blade on the resulting life of the component, that the analysis can predict this variation, and that experimental testing demonstrates it.
2014-01-01
pressure of 325 kPa (40 psi) at the peak of the temperature ramp of the cure schedule (13). The higher hold pressure requires the use of a high -pressure...Henkel Corporation Aerospace Group. Hysol EA 9896 Peel Ply; Preliminary Technical Datasheet, Bay Point, CA, February 2010. 11. Airtech Advanced ...using FM 94K epoxy film adhesive by mechanical testing, elemental surface analysis, and high -resolution imaging of failure surfaces. Woven S2
Layered Composite Analysis Capability
NASA Technical Reports Server (NTRS)
Narayanaswami, R.; Cole, J. G.
1985-01-01
Laminated composite material construction is gaining popularity within industry as an attractive alternative to metallic designs where high strength at reduced weights is of prime consideration. This has necessitated the development of an effective analysis capability for the static, dynamic and buckling analyses of structural components constructed of layered composites. Theoretical and user aspects of layered composite analysis and its incorporation into CSA/NASTRAN are discussed. The availability of stress and strain based failure criteria is described which aids the user in reviewing the voluminous output normally produced in such analyses. Simple strategies to obtain minimum weight designs of composite structures are discussed. Several example problems are presented to demonstrate the accuracy and user convenient features of the capability.
Patel, Gita Wasan; Duquaine, Susan M; McKinnon, Peggy S
2007-12-01
To compare outcomes and cost for the traditional United States Food and Drug Administration-approved dosing regimen for meropenem versus an alternative dosing regimen providing similar pharmacodynamic exposure with a lower total daily dose. Retrospective cohort study with a cost-minimization analysis. A 417-bed, privately owned community hospital. One hundred patients who received meropenem 1 g every 8 or 12 hours (traditional dosing regimen) between January 1 and September 30, 2004 (historical controls), and 192 patients who received meropenem 500 mg every 6 or 8 hours (alternative dosing regimen) between October 1, 2004, and September 30, 2005. Demographic and clinical data were collected for all patients. Cost-minimization analysis was performed by using the drug acquisition cost for meropenem. Demographics, sources of infection, distributions of organisms, and Charlson Comorbidity Index scores were similar between patients in the traditionally and alternatively dosed groups. Concomitant therapy, duration of therapy, success rates, lengths of stay, and in-hospital mortality rates were also similar between groups. Median time to the resolution of symptoms was 3 days for traditional dosing and 1.5 days for alternative dosing (p<0.0001). A logistic regression model including the dosing strategy showed that only polymicrobial infections and sepsis were associated with increased failure rates. The median cost for antibiotics was $439.05/patient for traditional dosing and $234.08/patient for alternative dosing (p<0.0001). An alternative dosing regimen for meropenem with a lower total daily dose yielded patient outcomes, including success rates and duration of therapy, equivalent to those of the traditional dosing regimen. Alternative dosing decreased total drug exposure, costs for antibiotics, and time to the resolution of infections.
NASA Technical Reports Server (NTRS)
Beatty, R.
1971-01-01
Metallization-related failure mechanisms were shown to be a major cause of integrated circuit failures under accelerated stress conditions, as well as in actual use under field operation. The integrated circuit industry is aware of the problem and is attempting to solve it in one of two ways: (1) better understanding of the aluminum system, which is the most widely used metallization material for silicon integrated circuits both as a single level and multilevel metallization, or (2) evaluating alternative metal systems. Aluminum metallization offers many advantages, but also has limitations particularly at elevated temperatures and high current densities. As an alternative, multilayer systems of the general form, silicon device-metal-inorganic insulator-metal, are being considered to produce large scale integrated arrays. The merits and restrictions of metallization systems in current usage and systems under development are defined.
Kanapathipillai, Rupa; McManus, Hamish; Kamarulzaman, Adeeba; Lim, Poh Lian; Templeton, David J; Law, Matthew; Woolley, Ian
2014-01-01
Magnitude and frequency of HIV viral load blips in resource-limited settings, has not previously been assessed. This study was undertaken in a cohort from a high income country (Australia) known as AHOD (Australian HIV Observational Database) and another cohort from a mixture of Asian countries of varying national income per capita, TAHOD (TREAT Asia HIV Observational Database). Blips were defined as detectable VL (≥ 50 copies/mL) preceded and followed by undetectable VL (<50 copies/mL). Virological failure (VF) was defined as two consecutive VL ≥50 copies/ml. Cox proportional hazard models of time to first VF after entry, were developed. 5040 patients (AHOD n = 2597 and TAHOD n = 2521) were included; 910 (18%) of patients experienced blips. 744 (21%) and 166 (11%) of high- and middle/low-income participants, respectively, experienced blips ever. 711 (14%) experienced blips prior to virological failure. 559 (16%) and 152 (10%) of high- and middle/low-income participants, respectively, experienced blips prior to virological failure. VL testing occurred at a median frequency of 175 and 91 days in middle/low- and high-income sites, respectively. Longer time to VF occurred in middle/low income sites, compared with high-income sites (adjusted hazards ratio (AHR) 0.41; p<0.001), adjusted for year of first cART, Hepatitis C co-infection, cART regimen, and prior blips. Prior blips were not a significant predictor of VF in univariate analysis (AHR 0.97, p = 0.82). Differing magnitudes of blips were not significant in univariate analyses as predictors of virological failure (p = 0.360 for blip 50-≤1000, p = 0.309 for blip 50-≤400 and p = 0.300 for blip 50-≤200). 209 of 866 (24%) patients were switched to an alternate regimen in the setting of a blip. Despite a lower proportion of blips occurring in low/middle-income settings, no significant difference was found between settings. Nonetheless, a substantial number of participants were switched to alternative regimens in the setting of blips.
The 2-year cost-effectiveness of 3 options to treat lumbar spinal stenosis patients.
Udeh, Belinda L; Costandi, Shrif; Dalton, Jarrod E; Ghosh, Raktim; Yousef, Hani; Mekhail, Nagy
2015-02-01
Lumbar spinal stenosis (LSS) may result from degenerative changes of the spine, which lead to neural ischemia, neurogenic claudication, and a significant decrease in quality of life. Treatments for LSS range from conservative management including epidural steroid injections (ESI) to laminectomy surgery. Treatments vary greatly in cost and success. ESI is the least costly treatment may be successful for early stages of LSS but often must be repeated frequently. Laminectomy surgery is more costly and has higher complication rates. Minimally invasive lumbar decompression (mild(®) ) is an alternative. Using a decision-analytic model from the Medicare perspective, a cost-effectiveness analysis was performed comparing mild(®) to ESI or laminectomy surgery. The analysis population included patients with LSS who have moderate to severe symptoms and have failed conservative therapy. Costs included initial procedure, complications, and repeat/revision or alternate procedure after failure. Effects measured as change in quality-adjusted life years (QALY) from preprocedure to 2 years postprocedure. Incremental cost-effectiveness ratios were determined, and sensitivity analysis conducted. The mild(®) strategy appears to be the most cost-effective ($43,760/QALY), with ESI the next best alternative at an additional $37,758/QALY. Laminectomy surgery was the least cost-effective ($125,985/QALY). © 2014 World Institute of Pain.
[Alternatives to conventional diuretic therapy in heart failure].
Morales-Rull, José Luis; Trullàs, Joan Carles; Formiga, Francesc
2014-03-01
Although treatment of acute heart failure is based primarily on the administration of intravenous loop diuretics, evidence supporting this practice is still scarce and there is uncertainty about the optimal dose. The existence of a considerable percentage of patients refractory to diuretic therapy and worsening of renal failure associated with the use of these drugs, with possible implications for medium-term mortality, have prompted the search for more effective and safer alternatives. Extracorporeal purification techniques, such as ultrafiltration, have demonstrated efficacy, although their superiority is unclear, due to the possible adverse effects associated with the procedure. The use of low-dose dopamine is not superior to conventional diuretic therapy after the first few hours of treatment. Moreover, combination with furosemide and hypertonic saline could be a valid alternative for patients with refractory congestion and depressed ejection fraction and serum creatinine ≤ 2.5mg/dL, but further studies are needed before its widespread use. The use of tolvaptan may be an effective alternative in the short-term but its use may be limited by its price. There is still controversy about whether treatment with loop diuretics is associated with higher mortality in all groups of patients with HF exacerbations. These controversies should be clarified by future clinical trials. Copyright © 2014 Elsevier España, S.L. All rights reserved.
Xiong, Tian-Yuan; Liao, Yan-Biao; Zhao, Zhen-Gang; Xu, Yuan-Ning; Wei, Xin; Zuo, Zhi-Liang; Li, Yi-Jian; Cao, Jia-Yu; Tang, Hong; Jilaihawi, Hasan; Feng, Yuan; Chen, Mao
2015-09-21
Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement in patients at high surgical risk. However, there is little published literature on the exact causes of death. The PubMed database was systematically searched for studies reporting causes of death within and after 30 days following TAVR. Twenty-eight studies out of 3934 results retrieved were identified. In the overall analysis, 46.4% and 51.6% of deaths were related to noncardiovascular causes within and after the first 30 days, respectively. Within 30 days of TAVR, infection/sepsis (18.5%), heart failure (14.7%), and multiorgan failure (13.2%) were the top 3 causes of death. Beyond 30 days, infection/sepsis (14.3%), heart failure (14.1%), and sudden death (10.8%) were the most common causes. All possible subgroup analyses were made. No significant differences were seen for proportions of cardiovascular deaths except the comparison between moderate (mean STS score 4 to 8) and high (mean STS score >8) -risk patients after 30 days post-TAVR (56.0% versus 33.5%, P=0.005). Cardiovascular and noncardiovascular causes of death are evenly balanced both in the perioperative period and at long-term follow-up after TAVR. Infection/sepsis and heart failure were the most frequent noncardiovascular and cardiovascular causes of death. This study highlights important areas of clinical focus that could further improve outcomes after TAVR. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
NASA Astrophysics Data System (ADS)
Rahman, Abdul Ghaffar Abdul; Noroozi, Siamak; Dupac, Mihai; Mahathir Syed Mohd Al-Attas, Syed; Vinney, John E.
2013-03-01
Complex rotating machinery requires regular condition monitoring inspections to assess their running conditions and their structural integrity to prevent catastrophic failures. Machine failures can be divided into two categories. First is the wear and tear during operation, they range from bearing defects, gear damage, misalignment, imbalance or mechanical looseness, for which simple condition-based maintenance techniques can easily detect the root cause and trigger remedial action process. The second factor in machine failure is caused by the inherent design faults that usually happened due to many reasons such as improper installation, poor servicing, bad workmanship and structural dynamics design deficiency. In fact, individual machines components are generally dynamically well designed and rigorously tested. However, when these machines are assembled on sight and linked together, their dynamic characteristics will change causing unexpected behaviour of the system. Since nondestructive evaluation provides an excellent alternative to the classical monitoring and proved attractive due to the possibility of performing reliable assessments of all types of machinery, the novel dynamic design verification procedure - based on the combination of in-service operation deflection shape measurement, experimental modal analysis and iterative inverse finite element analysis - proposed here allows quick identification of structural weakness, and helps to provide and verify the solutions.
Pavlova, Viola; Grimm, Volker; Dietz, Rune; Sonne, Christian; Vorkamp, Katrin; Rigét, Frank F; Letcher, Robert J; Gustavson, Kim; Desforges, Jean-Pierre; Nabe-Nielsen, Jacob
2016-01-01
Polychlorinated biphenyls (PCBs) can cause endocrine disruption, cancer, immunosuppression, or reproductive failure in animals. We used an individual-based model to explore whether and how PCB-associated reproductive failure could affect the dynamics of a hypothetical polar bear (Ursus maritimus) population exposed to PCBs to the same degree as the East Greenland subpopulation. Dose-response data from experimental studies on a surrogate species, the mink (Mustela vision), were used in the absence of similar data for polar bears. Two alternative types of reproductive failure in relation to maternal sum-PCB concentrations were considered: increased abortion rate and increased cub mortality. We found that the quantitative impact of PCB-induced reproductive failure on population growth rate depended largely on the actual type of reproductive failure involved. Critical potencies of the dose-response relationship for decreasing the population growth rate were established for both modeled types of reproductive failure. Comparing the model predictions of the age-dependent trend of sum-PCBs concentrations in females with actual field measurements from East Greenland indicated that it was unlikely that PCB exposure caused a high incidence of abortions in the subpopulation. However, on the basis of this analysis, it could not be excluded that PCB exposure contributes to higher cub mortality. Our results highlight the necessity for further research on the possible influence of PCBs on polar bear reproduction regarding their physiological pathway. This includes determining the exact cause of reproductive failure, i.e., in utero exposure versus lactational exposure of offspring; the timing of offspring death; and establishing the most relevant reference metrics for the dose-response relationship.
Kaspar, Mathias; Fette, Georg; Güder, Gülmisal; Seidlmayer, Lea; Ertl, Maximilian; Dietrich, Georg; Greger, Helmut; Puppe, Frank; Störk, Stefan
2018-04-17
Heart failure is the predominant cause of hospitalization and amongst the leading causes of death in Germany. However, accurate estimates of prevalence and incidence are lacking. Reported figures originating from different information sources are compromised by factors like economic reasons or documentation quality. We implemented a clinical data warehouse that integrates various information sources (structured parameters, plain text, data extracted by natural language processing) and enables reliable approximations to the real number of heart failure patients. Performance of ICD-based diagnosis in detecting heart failure was compared across the years 2000-2015 with (a) advanced definitions based on algorithms that integrate various sources of the hospital information system, and (b) a physician-based reference standard. Applying these methods for detecting heart failure in inpatients revealed that relying on ICD codes resulted in a marked underestimation of the true prevalence of heart failure, ranging from 44% in the validation dataset to 55% (single year) and 31% (all years) in the overall analysis. Percentages changed over the years, indicating secular changes in coding practice and efficiency. Performance was markedly improved using search and permutation algorithms from the initial expert-specified query (F1 score of 81%) to the computer-optimized query (F1 score of 86%) or, alternatively, optimizing precision or sensitivity depending on the search objective. Estimating prevalence of heart failure using ICD codes as the sole data source yielded unreliable results. Diagnostic accuracy was markedly improved using dedicated search algorithms. Our approach may be transferred to other hospital information systems.
Lee, Kyung Tai; Kim, Eung Soo; Kim, Young Ho; Ryu, Je Seong; Rhyu, Im Joo; Lee, Young Koo
2016-04-01
The all-inside arthroscopic modified Broström operation has been developed for lateral ankle instability. We compared the biomechanical parameters of the all-inside arthroscopic procedure to the open modified Broström operation. Eleven matched pairs of human cadaver specimens [average age 71.5 (range 58-98) years] were subject to the arthroscopic modified Broström operation using a suture anchor and the open modified Broström operation. The ligaments were loaded cyclically 20 times and then tested to failure. Torque to failure, degrees to failure, and stiffness were measured. A matched-pair analysis was performed. There was no significant difference in torque to failure between the open and arthroscopic modified Broström operation (19.9 ± 8.9 vs. 23.3 ± 12.1 Nm, n.s). The degrees to failure did not differ significantly between the open and arthroscopic modified Broström operations (46.8 ± 9.9° vs. 46.7 ± 7.6°, n.s). The working construct stiffness (or stiffness to failure) was no significant difference in the two groups (0.438 ± 0.21 vs. 0.487 ± 0.268 Nm/deg for the open and arthroscopic modified Broström operations, respectively, n.s). The all-inside arthroscopic modified Broström operation and the open modified Broström operation resulted in no significantly different torque to failure, degrees to failure, and working construct stiffness with no significant differences (n.s, n.s, and n.s, respectively). Our results indicate that the arthroscopic modified Broström operation is a reasonable alternative procedure for chronic ankle instability.
NASA Technical Reports Server (NTRS)
Kelly, Michael J.
2013-01-01
The Alternative Fuel Effects on Contrails and Cruise Emissions (ACCESS) Project Integration Manager requested in July 2012 that the NASA Engineering and Safety Center (NESC) form a team to independently assess aircraft structural failure hazards associated with the ACCESS experiment and to identify potential flight test hazard mitigations to ensure flight safety. The ACCESS Project Integration Manager subsequently requested that the assessment scope be focused predominantly on structural failure risks to the aircraft empennage (horizontal and vertical tail). This report contains the Appendices to Volume I.
Methods for analysis of cracks in three-dimensional solids
NASA Technical Reports Server (NTRS)
Raju, I. S.; Newman, J. C., Jr.
1984-01-01
Analytical and numerical methods evaluating the stress-intensity factors for three-dimensional cracks in solids are presented, with reference to fatigue failure in aerospace structures. The exact solutions for embedded elliptical and circular cracks in infinite solids, and the approximate methods, including the finite-element, the boundary-integral equation, the line-spring models, and the mixed methods are discussed. Among the mixed methods, the superposition of analytical and finite element methods, the stress-difference, the discretization-error, the alternating, and the finite element-alternating methods are reviewed. Comparison of the stress-intensity factor solutions for some three-dimensional crack configurations showed good agreement. Thus, the choice of a particular method in evaluating the stress-intensity factor is limited only to the availability of resources and computer programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pringle, C.S.
1997-12-30
Ballistic missile defense is the morally and strategically superior alternative to the current system of deterrence, provided that it is responsibly implemented. Analysis of the Just War Criteria and the utilitarian justifications of deterrence present a moral obligation to pursue the alternative strategy of missile defense as a means of defending the United States. However, the Anti-Ballistic Missile (ABM) Treaty does not allow earnest pursuit of this alternative, despite recent efforts to exploit its loopholes and broaden its meaning beyond any reasonable limit. Moreover, deterrence can no longer provide the guarantee of security that it did during the Cold War.more » Offense-Defense Theory shows that revisionist states are not subject to the same calculations of effective deterrence that the Soviet Union was during that period. This strategic analysis underlies the moral evaluations and further supports missile defense. The cult of deterrence is presented as an explanation for the failure to adapt national security policy to the new international structure, as European powers failed to perceive the offense-defense balance prior to World War I. The ABM regime threatens to reproduce those same mistakes with even greater consequences.« less
Propylthiouracil-Induced Acute Liver Failure: Role of Liver Transplantation
Carrion, Andres F.; Czul, Frank; Arosemena, Leopoldo R.; Selvaggi, Gennaro; Garcia, Monica T.; Tekin, Akin; Tzakis, Andreas G.; Martin, Paul; Ghanta, Ravi K.
2010-01-01
Propylthiouracil- (PTU-) induced hepatotoxicity is rare but potentially lethal with a spectrum of liver injury ranging from asymptomatic elevation of transaminases to fulminant hepatic failure and death. We describe two cases of acute hepatic failure due to PTU that required liver transplantation. Differences in the clinical presentation, histological characteristics, and posttransplant management are described as well as alternative therapeutic options. Frequent monitoring for PTU-induced hepatic dysfunction is strongly advised because timely discontinuation of this drug and implementation of noninvasive therapeutic interventions may prevent progression to liver failure or even death. PMID:21234410
Oellgaard, Jens; Gæde, Peter; Rossing, Peter; Rørth, Rasmus; Køber, Lars; Parving, Hans-Henrik; Pedersen, Oluf
2018-05-30
In type 2 diabetes mellitus, heart failure is a frequent, potentially fatal and often forgotten complication. Glucose-lowering agents and adjuvant therapies modify the risk of heart failure. We recently reported that 7.8 years of intensified compared with conventional multifactorial intervention in individuals with type 2 diabetes and microalbuminuria in the Steno-2 study reduced the risk of cardiovascular disease and prolonged life over 21.2 years of follow-up. In this post hoc analysis, we examine the impact of intensified multifactorial intervention on the risk of hospitalisation for heart failure. One hundred and sixty individuals were randomised to conventional or intensified multifactorial intervention, using sealed envelopes. The trial was conducted using the Prospective, Randomised, Open, Blinded Endpoints (PROBE) design. After 7.8 years, all individuals were offered intensified therapy and the study continued as an observational follow-up study for an additional 13.4 years. Heart-failure hospitalisations were adjudicated from patient records by an external expert committee blinded for treatment allocation. Event rates were compared using a Cox regression model adjusted for age and sex. Eighty patients were assigned to each treatment group. Ten patients undergoing intensive therapy vs 24 undergoing conventional therapy were hospitalised for heart failure during follow-up. The HR (95% CI) was 0.30 (0.14, 0.64), p = 0.002 in the intensive-therapy group compared with the conventional-therapy group. Including death in the endpoint did not lead to an alternate overall outcome; HR 0.51 (0.34, 0.76), p = 0.001. In a pooled cohort analysis, an increase in plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) during the first two years of the trial was associated with incident heart failure. Intensified, multifactorial intervention for 7.8 years in type 2 diabetic individuals with microalbuminuria reduced the risk of hospitalisation for heart failure by 70% during a total of 21.2 years of observation. ClinicalTrials.gov NCT00320008.
On the use of temperature for online condition monitoring of geared systems - A review
NASA Astrophysics Data System (ADS)
Touret, T.; Changenet, C.; Ville, F.; Lalmi, M.; Becquerelle, S.
2018-02-01
Gear unit condition monitoring is a key factor for mechanical system reliability management. When they are subjected to failure, gears and bearings may generate excessive vibration, debris and heat. Vibratory, acoustic or debris analyses are proven approaches to perform condition monitoring. An alternative to those methods is to use temperature as a condition indicator to detect gearbox failure. The review focuses on condition monitoring studies which use this thermal approach. According to the failure type and the measurement method, it exists a distinction whether it is contact (e.g. thermocouple) or non-contact temperature sensor (e.g. thermography). Capabilities and limitations of this approach are discussed. It is shown that the use of temperature for condition monitoring has a clear potential as an alternative to vibratory or acoustic health monitoring.
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2014 CFR
2014-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2012 CFR
2012-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
BWR Steam Dryer Alternating Stress Assessment Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morante, R. J.; Hambric, S. A.; Ziada, S.
2016-12-01
This report presents an overview of Boiling Water Reactor (BWR) steam dryer design; the fatigue cracking failures that occurred at the Quad Cities (QC) plants and their root causes; a history of BWR Extended Power Uprates (EPUs) in the USA; and a discussion of steam dryer modifications/replacements, alternating stress mechanisms on steam dryers, and structural integrity evaluations (static and alternating stress).
ERIC Educational Resources Information Center
Elwood, Bryan C.
This report provides a procedure by which the educational administrator can select from available alternatives the best method for transporting students and can evaluate at intervals the success or failure of the method selected. The report outlines the methodology used to analyze the problem, defines the range of alternatives called the…
Reliability study of refractory gate gallium arsenide MESFETS
NASA Technical Reports Server (NTRS)
Yin, J. C. W.; Portnoy, W. M.
1981-01-01
Refractory gate MESFET's were fabricated as an alternative to aluminum gate devices, which have been found to be unreliable as RF power amplifiers. In order to determine the reliability of the new structures, statistics of failure and information about mechanisms of failure in refractory gate MESFET's are given. Test transistors were stressed under conditions of high temperature and forward gate current to enhance failure. Results of work at 150 C and 275 C are reported.
Reliability study of refractory gate gallium arsenide MESFETS
NASA Astrophysics Data System (ADS)
Yin, J. C. W.; Portnoy, W. M.
Refractory gate MESFET's were fabricated as an alternative to aluminum gate devices, which have been found to be unreliable as RF power amplifiers. In order to determine the reliability of the new structures, statistics of failure and information about mechanisms of failure in refractory gate MESFET's are given. Test transistors were stressed under conditions of high temperature and forward gate current to enhance failure. Results of work at 150 C and 275 C are reported.
Smith, C W; Snyder, D R; Handelsman, M M
1982-02-01
The present study investigated the hypothesis that psychological symptoms may serve a self-protective function by providing an alternative explanation for potential failure in evaluating situations. It was hypothesized that highly test-anxious subjects would report anxiety symptoms in a pattern that reflected strategic presentation of symptoms; more specifically, it was predicted that greater reported anxiety should result when anxiety was a viable explanation for poor performance on an intelligence test and that lower reported anxiety should result when anxiety was not a viable explanation for poor performance. Analysis of state measures of self-reported anxiety supported these predictions. Further analysis indicated that when anxiety was not a viable explanation for poor test performance, high test-anxiety subjects reported reduced effort as an alternative self-protective strategy. These results are discussed in terms of traditional models of symptoms as self-protective strategies, current social psychological models of symptoms, and in reference to recent theory and research about the nature and treatment of test anxiety.
Impact of distributed energy resources on the reliability of a critical telecommunications facility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, David; Zuffranieri, Jason V.; Atcitty, Christopher B.
2006-03-01
This report documents a probabilistic risk assessment of an existing power supply system at a large telecommunications office. The focus is on characterizing the increase in the reliability of power supply through the use of two alternative power configurations. Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages. A logical approach to improve the robustness of telecommunication facilities would be to increase the depth and breadth of technologies available to restore power inmore » the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less
Design/Analysis of Metal/Composite Bonded Joints for Survivability at Cryogenic Temperatures
NASA Technical Reports Server (NTRS)
Bartoszyk, Andrew E.
2004-01-01
A major design and analysis challenge for the JWST ISM structure is the metal/composite bonded joints that will be required to survive down to an operational ultra-low temperature of 30K (-405 F). The initial and current baseline design for the plug-type joint consists of a titanium thin walled fitting (1-3mm thick) bonded to the interior surface of an M555/954-6 composite truss square tube with an axially stiff biased lay-up. Metallic fittings are required at various nodes of the truss structure to accommodate instrument and lift-point bolted interfaces. Analytical experience and design work done on metal/composite bonded joints at temperatures below liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are virtually nonexistent. Increasing the challenge is the difficulty in testing for these required tools and parameters at 30K. A preliminary finite element analysis shows that failure due to CTE mismatch between the biased composite and titanium or aluminum is likely. Failure is less likely with Invar, however an initial mass estimate of Invar fittings demonstrates that Invar is not an automatic alternative. In order to gain confidence in analyzing and designing the ISM joints, a comprehensive joint development testing program has been planned and is currently running. The test program is designed for the correlation of the analysis methodology, including tuning finite element model parameters, and developing a composite failure criterion for the effect of multi-axial composite stresses on the strength of a bonded joint at 30K. The testing program will also consider stress mitigation using compliant composite layers and potential strength degradation due to multiple thermal cycles. Not only will the finite element analysis be correlated to the test data, but the FEA will be used to guide the design of the test. The first phase of the test program has been completed and the preliminary analysis has been revisited based on the test data In this work, we present an overview of the test plan, results today, and resulting design improvements.
Sustainability - What are the Odds? Guessing the Future of our Environment, Economy, and Society
This article examines the concept of sustainability from a global perspective, describing how alternative futures might develop in the environmental, economic, and social dimensions. The alternatives to sustainability appear to be (a) a catastrophic failure of life support, econo...
NASA Astrophysics Data System (ADS)
Luo, X. M.; Zhang, B.; Zhang, G. P.
2014-09-01
Thermal fatigue failure of metallization interconnect lines subjected to alternating currents (AC) is becoming a severe threat to the long-term reliability of micro/nanodevices with increasing electrical current density/power. Here, thermal fatigue failure behaviors and damage mechanisms of nanocrystalline Au interconnect lines on the silicon glass substrate have been investigated by applying general alternating currents (the pure alternating current coupled with a direct current (DC) component) with different frequencies ranging from 0.05 Hz to 5 kHz. We observed both thermal fatigue damages caused by Joule heating-induced cyclic strain/stress and electromigration (EM) damages caused by the DC component. Besides, the damage formation showed a strong electrically-thermally-mechanically coupled effect and frequency dependence. At lower frequencies, thermal fatigue damages were dominant and the main damage forms were grain coarsening with grain boundary (GB) cracking/voiding and grain thinning. At higher frequencies, EM damages took over and the main damage forms were GB cracking/voiding of smaller grains and hillocks. Furthermore, the healing effect of the reversing current was considered to elucidate damage mechanisms of the nanocrystalline Au lines generated by the general AC. Lastly, a modified model was proposed to predict the lifetime of the nanocrystalline metal interconnect lines, i.e., that was a competing drift velocity-based approach based on the threshold time required for reverse diffusion/healing to occur.
Schiffl, H; Lang, S M; Haider, M
1998-01-01
The mortality rate of critically ill patients with acute renal failure (ARF) has remained high. The impact of vigorous intermittent hemodialysis (IHD) on the outcome of ARF has not been validated. In this retrospective multicenter analysis, 154 patients with ARF were treated daily (intensive) or on alternate days (conventional) using complement and cell activating cuprophane (bioincompatible) or high-flux polysulfone dialyzer membranes with insignificant effects on circulating complement or cells (biocompatible). At initiation of IHD, all four groups were similar in patient characteristics and ARF factors. The use of synthetic membranes resulted in a reduced mortality rate (18% vs 45%; p < 0.001) and shorter duration of ARF (8 vs 15 sessions; p < 0.001). Daily IHD with cellulose based membranes tended to increase mortality rates compared with conventional cuprophane dialysis (37% vs 53%). Intensive IHD with polysulfone membranes resulted in a further decrease in overall mortality rates (15% vs 22%). This retrospective analysis shows that bioincompatibility of dialyzer membranes may be more important for the outcome of patients with ARF than the dose of dialysis. Its impact on outcome occurs independently of the dose of dialysis delivered.
Outcome-Dependent Sampling with Interval-Censored Failure Time Data
Zhou, Qingning; Cai, Jianwen; Zhou, Haibo
2017-01-01
Summary Epidemiologic studies and disease prevention trials often seek to relate an exposure variable to a failure time that suffers from interval-censoring. When the failure rate is low and the time intervals are wide, a large cohort is often required so as to yield reliable precision on the exposure-failure-time relationship. However, large cohort studies with simple random sampling could be prohibitive for investigators with a limited budget, especially when the exposure variables are expensive to obtain. Alternative cost-effective sampling designs and inference procedures are therefore desirable. We propose an outcome-dependent sampling (ODS) design with interval-censored failure time data, where we enrich the observed sample by selectively including certain more informative failure subjects. We develop a novel sieve semiparametric maximum empirical likelihood approach for fitting the proportional hazards model to data from the proposed interval-censoring ODS design. This approach employs the empirical likelihood and sieve methods to deal with the infinite-dimensional nuisance parameters, which greatly reduces the dimensionality of the estimation problem and eases the computation difficulty. The consistency and asymptotic normality of the resulting regression parameter estimator are established. The results from our extensive simulation study show that the proposed design and method works well for practical situations and is more efficient than the alternative designs and competing approaches. An example from the Atherosclerosis Risk in Communities (ARIC) study is provided for illustration. PMID:28771664
Rational Temporal Predictions Can Underlie Apparent Failures to Delay Gratification
ERIC Educational Resources Information Center
McGuire, Joseph T.; Kable, Joseph W.
2013-01-01
An important category of seemingly maladaptive decisions involves failure to postpone gratification. A person pursuing a desirable long-run outcome may abandon it in favor of a short-run alternative that has been available all along. Here we present a theoretical framework in which this seemingly irrational behavior emerges from stable preferences…
Alternative right ventricular pacing sites.
Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek
2015-01-01
The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.
Is methoxyflurane a suitable battlefield analgesic?
McLennan, J V
2007-06-01
Anecdotal reports of mechanical failure of morphine autojets have triggered a review of possible alternatives. Methoxyflurane is one such alternative already widely used by the Australian and New Zealand Defence Forces. The potential benefits and likely significant drawbacks of methoxyflurane are reviewed with the aim of stimulating discussion.
Alternative model of thrust-fault propagation
NASA Astrophysics Data System (ADS)
Eisenstadt, Gloria; de Paor, Declan G.
1987-07-01
A widely accepted explanation for the geometry of thrust faults is that initial failures occur on deeply buried planes of weak rock and that thrust faults propagate toward the surface along a staircase trajectory. We propose an alternative model that applies Gretener's beam-failure mechanism to a multilayered sequence. Invoking compatibility conditions, which demand that a thrust propagate both upsection and downsection, we suggest that ramps form first, at shallow levels, and are subsequently connected by flat faults. This hypothesis also explains the formation of many minor structures associated with thrusts, such as backthrusts, wedge structures, pop-ups, and duplexes, and provides a unified conceptual framework in which to evaluate field observations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hueter, J.M.
Creativity involves the associating of hitherto unrelated elements to form a new and useful combination. All have the ability but most seldom use it because of some false beliefs and failure to understand the creative process. Deterrents to creativity include fear of criticism, narrowness of education and training, habit, negative attitudes toward problems, lack of motivation, lack of self-confidence, lack of courage and discouragement by failures. The recognition and development of creative ideas requires mental effort, an open mind, searching seemingly unrelated fields and definition of the problem. Brainstorming is widely used to produce alternate ideas. Modifications of it aremore » the Gordon Technique and Synectics. Morphological analysis and the examination of attributes are other aids to creativity. Recognition of a need, or of a new use of an old idea can be helpful. Management should encourage attempts at creativity. If the will exists, creativity can be developed by conscious effort instead of being left to chance.« less
A Comparison of Two Approaches to Safety Analysis Based on Use Cases
NASA Astrophysics Data System (ADS)
Stålhane, Tor; Sindre, Guttorm
Engineering has a long tradition in analyzing the safety of mechanical, electrical and electronic systems. Important methods like HazOp and FMEA have also been adopted by the software engineering community. The misuse case method, on the other hand, has been developed by the software community as an alternative to FMEA and preliminary HazOp for software development. To compare the two methods misuse case and FMEA we have run a small experiment involving 42 third year software engineering students. In the experiment, the students should identify and analyze failure modes from one of the use cases for a commercial electronic patient journals system. The results of the experiment show that on the average, the group that used misuse cases identified and analyzed more user related failure modes than the persons using FMEA. In addition, the persons who used the misuse cases scored better on perceived ease of use and intention to use.
Application of Single Crystal Failure Criteria: Theory and Turbine Blade Case Study
NASA Technical Reports Server (NTRS)
Sayyah, Tarek; Swanson, Gregory R.; Schonberg, W. P.
1999-01-01
The orientation of the single crystal material within a structural component is known to affect the strength and life of the part. The first stage blade of the High Pressure Fuel Turbopump (HPFTP)/ Alternative Turbopump Development (ATD), of the Space Shuttle Main Engine (SSME) was used to study the effects of secondary axis'orientation angles on the failure rate of the blade. A new failure criterion was developed based on normal and shear strains on the primary crystallographic planes. The criterion was verified using low cycle fatigue (LCF) specimen data and a finite element model of the test specimens. The criterion was then used to study ATD/HPFTP first stage blade failure events. A detailed ANSYS finite element model of the blade was used to calculate the failure parameter for the different crystallographic orientations. A total of 297 cases were run to cover a wide range of acceptable orientations within the blade. Those orientations are related to the base crystallographic coordinate system that was created in the ANSYS finite element model. Contour plots of the criterion as a function of orientation for the blade tip and attachment were obtained. Results of the analysis revealed a 40% increase in the failure parameter due to changing of the primary and secondary axes of material orientations. A comparison between failure criterion predictions and actual engine test data was then conducted. The engine test data comes from two ATD/HPFTP builds (units F3- 4B and F6-5D), which were ground tested on the SSME at the Stennis Space Center in Mississippi. Both units experienced cracking of the airfoil tips in multiple blades, but only a few cracks grew all the way across the wall of the hollow core airfoil.
Forecasting overhaul or replacement intervals based on estimated system failure intensity
NASA Astrophysics Data System (ADS)
Gannon, James M.
1994-12-01
System reliability can be expressed in terms of the pattern of failure events over time. Assuming a nonhomogeneous Poisson process and Weibull intensity function for complex repairable system failures, the degree of system deterioration can be approximated. Maximum likelihood estimators (MLE's) for the system Rate of Occurrence of Failure (ROCOF) function are presented. Evaluating the integral of the ROCOF over annual usage intervals yields the expected number of annual system failures. By associating a cost of failure with the expected number of failures, budget and program policy decisions can be made based on expected future maintenance costs. Monte Carlo simulation is used to estimate the range and the distribution of the net present value and internal rate of return of alternative cash flows based on the distributions of the cost inputs and confidence intervals of the MLE's.
Academic Remediation-Focused Alternative Schools: Impact on Student Outcomes
ERIC Educational Resources Information Center
Wilkerson, Kimber L.; Afacan, Kemal; Yan, Min-Chi; Justin, Whitney; Datar, Sujata D.
2016-01-01
School districts offer specialized programming for secondary students who experience high rates of course failure or low credit accumulation. While these alternative programs are meant to increase student success, little research evaluates outcomes for students attending them. In this study, we used propensity score matching (PSM) to investigate…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... Boeing Model 787-8 airplane will incorporate a fuel tank nitrogen generation system (NGS) that actively... ignition source in the fuel tank system could not result from any single failure, from any single failure... of fuel systems. We do not intend to apply the alternative standards used under these special...
Kanapathipillai, Rupa; McManus, Hamish; Kamarulzaman, Adeeba; Lim, Poh Lian; Templeton, David J.; Law, Matthew; Woolley, Ian
2014-01-01
Introduction Magnitude and frequency of HIV viral load blips in resource-limited settings, has not previously been assessed. This study was undertaken in a cohort from a high income country (Australia) known as AHOD (Australian HIV Observational Database) and another cohort from a mixture of Asian countries of varying national income per capita, TAHOD (TREAT Asia HIV Observational Database). Methods Blips were defined as detectable VL (≥ 50 copies/mL) preceded and followed by undetectable VL (<50 copies/mL). Virological failure (VF) was defined as two consecutive VL ≥50 copies/ml. Cox proportional hazard models of time to first VF after entry, were developed. Results 5040 patients (AHOD n = 2597 and TAHOD n = 2521) were included; 910 (18%) of patients experienced blips. 744 (21%) and 166 (11%) of high- and middle/low-income participants, respectively, experienced blips ever. 711 (14%) experienced blips prior to virological failure. 559 (16%) and 152 (10%) of high- and middle/low-income participants, respectively, experienced blips prior to virological failure. VL testing occurred at a median frequency of 175 and 91 days in middle/low- and high-income sites, respectively. Longer time to VF occurred in middle/low income sites, compared with high-income sites (adjusted hazards ratio (AHR) 0.41; p<0.001), adjusted for year of first cART, Hepatitis C co-infection, cART regimen, and prior blips. Prior blips were not a significant predictor of VF in univariate analysis (AHR 0.97, p = 0.82). Differing magnitudes of blips were not significant in univariate analyses as predictors of virological failure (p = 0.360 for blip 50–≤1000, p = 0.309 for blip 50–≤400 and p = 0.300 for blip 50–≤200). 209 of 866 (24%) patients were switched to an alternate regimen in the setting of a blip. Conclusion Despite a lower proportion of blips occurring in low/middle-income settings, no significant difference was found between settings. Nonetheless, a substantial number of participants were switched to alternative regimens in the setting of blips. PMID:24516527
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Uccioli, Luigi; Spinelli, Alessio
The purpose of this study was to describe alternative endovascular (EV) techniques and assess their feasibility and efficacy in minimizing failure rates in limb salvage for the treatment of complex below-the knee (BTK) occlusions that could not be crossed with a conventional antegrade access. Between December 2007 and November 2010, 1,035 patients (557 male) underwent EV treatment for critical limb ischemia in our institution. In 124 (12% [83 male], mean age 68.2 {+-} 0.5 years) patients, transfemoral antegrade revascularization attempt failed, and an alternative approach was used. Follow-up was performed at 1 and 6 months. Results were compared with 56more » patients treated between November 2002 and November 2007, in whom conventional technique was unsuccessful and unconventional techniques were not adopted. Technical success was achieved in 119 (96%) patients. The limb-salvage rates were 96.8% and 83% at 1- and 6-month follow-up, respectively. Sixteen (12.9%) and 33 (26.6%) patients underwent reintervention at 1- and 6-month follow-up, respectively. Transcutaneous oxygen tension increased at 1 month (44.7 {+-} 1.1 vs. 15.7 {+-} 0.8 mmHg; p < 0.001) and remained stable at follow-up. Twenty (16.1%) patients required major amputation. Thirteen (10.4%) patients died during follow-up. In our previous experience, percutaneous transluminal angioplasty failure, amputation, and death rates were 10.9, 39.2, and 23.2%, respectively. Alternative techniques allowed a significant decrease of major amputation and death rates (p = 0.0001 and p = 0.02, respectively). The use of alternative techniques seems feasible in case of a failed antegrade BTK revascularization attempt and could minimize failure rates in the treatment of complex occlusions while providing satisfying clinical success rates at 6 months.« less
Progressive Failure Analysis Methodology for Laminated Composite Structures
NASA Technical Reports Server (NTRS)
Sleight, David W.
1999-01-01
A progressive failure analysis method has been developed for predicting the failure of laminated composite structures under geometrically nonlinear deformations. The progressive failure analysis uses C(exp 1) shell elements based on classical lamination theory to calculate the in-plane stresses. Several failure criteria, including the maximum strain criterion, Hashin's criterion, and Christensen's criterion, are used to predict the failure mechanisms and several options are available to degrade the material properties after failures. The progressive failure analysis method is implemented in the COMET finite element analysis code and can predict the damage and response of laminated composite structures from initial loading to final failure. The different failure criteria and material degradation methods are compared and assessed by performing analyses of several laminated composite structures. Results from the progressive failure method indicate good correlation with the existing test data except in structural applications where interlaminar stresses are important which may cause failure mechanisms such as debonding or delaminations.
AAC and RTI: building classroom-based strategies for every child in the classroom.
Grether, Sandra M; Sickman, Linda Sue
2008-05-01
Educators were previously encouraged to use IQ-achievement discrepancy to identify children with learning disabilities. The Individuals with Disabilities Education Improvement Act promotes an alternative method, response to intervention, or RTI, not only to identify these children but also to provide early intervention to all children at risk for school failure. Children with complex communication needs who use augmentative and alternative communication (AAC) are at risk for failure in the classroom and can benefit from the educational supports provided through RTI. This article discusses the levels of support provided by RTI, the speech-language pathologist's role in RTI, and strategies and supports for achieving academic success for children who use AAC.
Mathematical modeling of thermal stresses in basic oxygen furnace hood tubes
NASA Astrophysics Data System (ADS)
Samarasekera, I. V.
1985-06-01
The stress-strain history of Basic Oxygen Furnace hood tubes during thermal cycling has been computed using heat flow and stress analyses. The steady-state temperature distribution in a transverse section of the tube was computed at a location where gas temperature in the hood could be expected to be a maximum. Calculations were performed for peak gas temperatures in the range 1950 to 2480 °C (3500 to 4500 °F). The stress-strain history of an element of material located at the center of the tube hot face was traced for three consecutive cycles using elasto-plastic finite-element analysis. It has been shown that the state of stress in the element alternates between compression and tension as the tube successively heats and cools. Yielding and plastic flow occurs at the end of each half of a given cycle. It was postulated that owing to repctitive yielding, plastic strain energy accumulates causing failure of the tubes by fatigue in the low cycle region. Using fatigue theory a conservative estimate for tube life was arrived at. In-plant observations support this mechanism of failure, and the number of cycles within which tube cracking was observed compares reasonably with model predictions. Utilizing the heat flow and stress models it was recommended that tube life could be enhanced by changing the tube material to ARMCO 17-4 pH or AISI 405 steel or alternatively reconstructing hoods with AISI 316L tubes of reduced thickness. These recommendations were based on the criterion that low-cycle fatigue failure could be averted if the magnitude of the cyclic strain could be reduced or if macroscopic plastic flow could be prevented.
CRANS - CONFIGURABLE REAL-TIME ANALYSIS SYSTEM
NASA Technical Reports Server (NTRS)
Mccluney, K.
1994-01-01
In a real-time environment, the results of changes or failures in a complex, interconnected system need evaluation quickly. Tabulations showing the effects of changes and/or failures of a given item in the system are generally only useful for a single input, and only with regard to that item. Subsequent changes become harder to evaluate as combinations of failures produce a cascade effect. When confronted by multiple indicated failures in the system, it becomes necessary to determine a single cause. In this case, failure tables are not very helpful. CRANS, the Configurable Real-time ANalysis System, can interpret a logic tree, constructed by the user, describing a complex system and determine the effects of changes and failures in it. Items in the tree are related to each other by Boolean operators. The user is then able to change the state of these items (ON/OFF FAILED/UNFAILED). The program then evaluates the logic tree based on these changes and determines any resultant changes to other items in the tree. CRANS can also search for a common cause for multiple item failures, and allow the user to explore the logic tree from within the program. A "help" mode and a reference check provide the user with a means of exploring an item's underlying logic from within the program. A commonality check determines single point failures for an item or group of items. Output is in the form of a user-defined matrix or matrices of colored boxes, each box representing an item or set of items from the logic tree. Input is via mouse selection of the matrix boxes, using the mouse buttons to toggle the state of the item. CRANS is written in C-language and requires the MIT X Window System, Version 11 Revision 4 or Revision 5. It requires 78K of RAM for execution and a three button mouse. It has been successfully implemented on Sun4 workstations running SunOS, HP9000 workstations running HP-UX, and DECstations running ULTRIX. No executable is provided on the distribution medium; however, a sample makefile is included. Sample input files are also included. The standard distribution medium is a .25 inch streaming magnetic tape cartridge (Sun QIC-24) in UNIX tar format. Alternate distribution media and formats are available upon request. This program was developed in 1992.
ERIC Educational Resources Information Center
Mbwiri, Francis I.
2017-01-01
Many students with disabilities attending alternative high schools are not improving their mathematics ability scores. Failure to improve their mathematics ability scores has hampered their potential academic success and career prospects, resulting in many students dropping out of schools without graduating. The purpose of this quantitative study…
Special Educators' Perceptions on Effective Preparation and Practice for Student Success
ERIC Educational Resources Information Center
Liese, Aerial Anne
2018-01-01
Alternative school settings are success prospects for students at risk of school failure. However, research on the daily experiences of the special educators in alternate school settings tasked with educating the at-risk population, is limited. The purpose of this phenomenological study was (a) to recognize the perceptions of special educators…
ERIC Educational Resources Information Center
Swift, Marshall S.; Spivack, George
This book provides (1) specific information about overt classroom behaviors that affect or reflect academic success or failure, and (2) information and suggestions about alternative teaching strategies that may be used to increase behavioral effectiveness and subsequent academic achievement. The focus of the book is on specific behaviors, behavior…
Evaluation of a Progressive Failure Analysis Methodology for Laminated Composite Structures
NASA Technical Reports Server (NTRS)
Sleight, David W.; Knight, Norman F., Jr.; Wang, John T.
1997-01-01
A progressive failure analysis methodology has been developed for predicting the nonlinear response and failure of laminated composite structures. The progressive failure analysis uses C plate and shell elements based on classical lamination theory to calculate the in-plane stresses. Several failure criteria, including the maximum strain criterion, Hashin's criterion, and Christensen's criterion, are used to predict the failure mechanisms. The progressive failure analysis model is implemented into a general purpose finite element code and can predict the damage and response of laminated composite structures from initial loading to final failure.
Alternate Design of ITER Cryostat Skirt Support System
NASA Astrophysics Data System (ADS)
Pandey, Manish Kumar; Jha, Saroj Kumar; Gupta, Girish Kumar; Bhattacharya, Avik; Jogi, Gaurav; Bhardwaj, Anil Kumar
2017-04-01
The skirt support of ITER cryostat is a support system which takes all the load of cryostat cylinder and dome during normal and operational condition. The present design of skirt support has full penetration weld joints at the bottom (shell to horizontal plate joint). To fulfil the requirements of tolerances and control the welding distortions, we have proposed to change the full penetration weld into fillet weld. A detail calculation is done to check the feasibility and structural impact due to proposed design. The calculations provide the size requirements of fillet weld. To verify the structural integrity during most severe load case, finite element analysis (FEA) has been done in line with ASME section VIII division 2 [1]. By FEA ‘Plastic Collapse’ and ‘Local Failure’ modes has been assessed. 5° sector of skirt clamp has been modelled in CATIA V5 R21 and used in FEA. Fillet weld at shell to horizontal plate joint has been modelled and symmetry boundary condition at ± 2.5° applied. ‘Elastic Plastic Analysis’ has been performed for the most severe loading case i.e. Category IV loading. The alternate design of Cryostat Skirt support system has been found safe by analysis against Plastic collapse and Local Failure Modes with load proportionality factor 2.3. Alternate design of Cryostat skirt support system has been done and validated by FEA. As per alternate design, the proposal of fillet weld has been implemented in manufacturing.
Yamaue, Hiroki; Shimizu, Atsushi; Hagiwara, Yasuhiro; Sho, Masayuki; Yanagimoto, Hiroaki; Nakamori, Shoji; Ueno, Hideki; Ishii, Hiroshi; Kitano, Masayuki; Sugimori, Kazuya; Maguchi, Hiroyuki; Ohkawa, Shinichi; Imaoka, Hiroshi; Hashimoto, Daisuke; Ueda, Kazuki; Nebiki, Hiroko; Nagakawa, Tatsuya; Isayama, Hiroyuki; Yokota, Isao; Ohashi, Yasuo; Shirasaka, Tetsuhiko
2017-04-01
Non-inferiority for overall survival (OS) following alternate-day treatment with the oral anticancer drug S-1 compared with standard daily treatment was assessed in Japanese patients with unresectable advanced pancreatic cancer in a multicenter, randomized, phase II study. This trial was registered at the UMIN Clinical Trials Registry (no. 000008604). Chemotherapy-naïve patients with locally advanced or metastatic pancreatic cancer were randomly assigned 2:1 to treatment with alternate-day (twice daily on alternate days from days 1 through 42 of a 42-day cycle) or daily (twice daily on days 1 through 28 of a 42-day cycle) treatment with S-1. The primary endpoint was OS. Secondary endpoints were progression-free survival (PFS), time to treatment failure, response rate, quality of life assessments, and safety. A total of 190 patients were enrolled, of which 185 were included in the final analysis (alternate-day: 121; daily: 64). Median OS was 9.4 for the alternate-day group and 10.4 months for the daily group [hazard ratio (HR), 1.19; 95% credible interval, 0.86 to 1.64], indicating that non-inferiority of alternate-day treatment to daily treatment was not demonstrated. Median PFS was 3.0 for the alternate-day group and 4.2 months for the daily group (HR, 1.65; 95% credible interval, 1.20-2.29). The incidence of anorexia, fatigue, neutrophils, pigmentation, and pneumonitis was lower in alternate-day treatment compared with daily treatment. S-1 for advanced pancreatic cancer should be taken daily as recommended, based on the decreased OS and PFS and marginal improvement in safety observed in the alternate-day group.
A Bayesian Framework for Human Body Pose Tracking from Depth Image Sequences
Zhu, Youding; Fujimura, Kikuo
2010-01-01
This paper addresses the problem of accurate and robust tracking of 3D human body pose from depth image sequences. Recovering the large number of degrees of freedom in human body movements from a depth image sequence is challenging due to the need to resolve the depth ambiguity caused by self-occlusions and the difficulty to recover from tracking failure. Human body poses could be estimated through model fitting using dense correspondences between depth data and an articulated human model (local optimization method). Although it usually achieves a high accuracy due to dense correspondences, it may fail to recover from tracking failure. Alternately, human pose may be reconstructed by detecting and tracking human body anatomical landmarks (key-points) based on low-level depth image analysis. While this method (key-point based method) is robust and recovers from tracking failure, its pose estimation accuracy depends solely on image-based localization accuracy of key-points. To address these limitations, we present a flexible Bayesian framework for integrating pose estimation results obtained by methods based on key-points and local optimization. Experimental results are shown and performance comparison is presented to demonstrate the effectiveness of the proposed approach. PMID:22399933
Factors Influencing Progressive Failure Analysis Predictions for Laminated Composite Structure
NASA Technical Reports Server (NTRS)
Knight, Norman F., Jr.
2008-01-01
Progressive failure material modeling methods used for structural analysis including failure initiation and material degradation are presented. Different failure initiation criteria and material degradation models are described that define progressive failure formulations. These progressive failure formulations are implemented in a user-defined material model for use with a nonlinear finite element analysis tool. The failure initiation criteria include the maximum stress criteria, maximum strain criteria, the Tsai-Wu failure polynomial, and the Hashin criteria. The material degradation model is based on the ply-discounting approach where the local material constitutive coefficients are degraded. Applications and extensions of the progressive failure analysis material model address two-dimensional plate and shell finite elements and three-dimensional solid finite elements. Implementation details are described in the present paper. Parametric studies for laminated composite structures are discussed to illustrate the features of the progressive failure modeling methods that have been implemented and to demonstrate their influence on progressive failure analysis predictions.
Prouvot, Catherine; Golfier, François; Massardier, Jérôme; You, Benoit; Lotz, Jean-Pierre; Patrier, Sophie; Devouassoux, Mojgan; Schott, Anne-Marie; Hajri, Touria; Bolze, Pierre-Adrien
2018-06-01
The objective of this study was to evaluate the characteristics and outcomes of patients treated for gestational trophoblastic neoplasia (GTN) with second-line 5-day dactinomycin after failed first-line 8-day methotrexate. From 1999 to 2017, patients with methotrexate resistant GTN treated with second line dactinomycin were identified at the French Trophoblastic Disease Reference Center. Using univariate and multivariate analysis, we identified significant predictive factors of second line dactinomycin failure. A total of 877 GTN patients were treated with first-line 8-day methotrexate, of which 103 required second-line 5-day dactinomycin for methotrexate failure. Complete response was observed in 78 patients (75.7% [95% confidence interval, 66.3-83.6]; P < 0.0001), whereas 25 needed third-line treatment, 13 for dactinomycin resistance and 12 for post-dactinomycin relapse. Overall survival of patients treated with dactinomycin was 100%. An interval of greater than or equal to 7 months between antecedent pregnancy termination and methotrexate initiation was a predictive factor significantly associated with second-line dactinomycin failure in multivariate analysis (exact odds ratio, 9.17 [95% confidence interval, 1.98-50.70]; P = 0.0029). No grades 4 and 5 adverse effects were experienced and the most common toxicity being grade 1 nausea (14.6%). Given a 75.7% complete response rate in methotrexate failed low-risk GTN patients treated with second-line dactinomycin and an overall survival rate of 100% after third-line treatment, the use of dactinomycin should be favored as second-line, regardless of human chorionic gonadotropin level at the time of dactinomycin initiation. However, an interval between the termination of the antecedent pregnancy and methotrexate initiation longer than 6 months should encourage considering alternative therapeutic strategies.
Addressing Production System Failures Using Multi-agent Control
NASA Astrophysics Data System (ADS)
Gautam, Rajesh; Miyashita, Kazuo
Output in high-volume production facilities is limited by bottleneck machines. We propose a control mechanism by modeling workstations as agents that pull jobs from other agents based on their current WIP level and requirements. During failures, when flows of some jobs are disrupted, the agents pull alternative jobs to maintain utilization of their capacity at a high level. In this paper, we empirically demonstrate that the proposed mechanism can react to failures more appropriately than other control mechanisms using a benchmark problem of a semiconductor manufacturing process.
Ambulatory intravenous ceftriaxone in paediatric A&E: a useful alternative to hospital admission?
Smith, Jennifer K; Alexander, Saji; Abrahamson, Ed
2011-10-01
Treatment of children with intravenous ceftriaxone on an ambulatory basis is described. This allows a child to remain at home, but also be reviewed regularly when attending the Emergency Department for antibiotics. Indications for, and length of, treatment and laboratory parameters were recorded. Also, a survey of children's parents was undertaken to ascertain opinions regarding ambulatory treatment. 36 patients were treated with ambulatory ceftriaxone over 4 months. Indications included fever without focus, tonsillitis, periorbital cellulitis, urinary tract infection, petechial rash and lymphadenitis. Median duration of treatment was 2.3 days. There was no occult bacteraemia but five positive urine cultures. There was one failure of treatment with subsequent admission for alternative intravenous antibiotics. Parental opinion favours ambulatory treatment, with 94% of parents acknowledging they would choose it again in similar circumstances. Cost analysis favours ambulatory treatment based on predicted costs of a similar length of inpatient stay.
The levels of analysis revisited
MacDougall-Shackleton, Scott A.
2011-01-01
The term levels of analysis has been used in several ways: to distinguish between ultimate and proximate levels, to categorize different kinds of research questions and to differentiate levels of reductionism. Because questions regarding ultimate function and proximate mechanisms are logically distinct, I suggest that distinguishing between these two levels is the best use of the term. Integrating across levels in research has potential risks, but many benefits. Consideration at one level can help generate novel hypotheses at the other, define categories of behaviour and set criteria that must be addressed. Taking an adaptationist stance thus strengthens research on proximate mechanisms. Similarly, it is critical for researchers studying adaptation and function to have detailed knowledge of proximate mechanisms that may constrain or modulate evolutionary processes. Despite the benefits of integrating across ultimate and proximate levels, failure to clearly identify levels of analysis, and whether or not hypotheses are exclusive alternatives, can create false debates. Such non-alternative hypotheses may occur between or within levels, and are not limited to integrative approaches. In this review, I survey different uses of the term levels of analysis and the benefits of integration, and highlight examples of false debate within and between levels. The best integrative biology reciprocally uses ultimate and proximate hypotheses to generate a more complete understanding of behaviour. PMID:21690126
Kline, A David
2006-04-01
The received account of whistleblowing, developed over the last quarter century, is identified with the work of Norman Bowie and Richard DeGeorge. Michael Davis has detailed three anomalies for the received view: the paradoxes of burden, missing harm and failure. In addition, he has proposed an alternative account of whistleblowing, viz., the Complicity Theory. This paper examines the Complicity Theory. The supposed anomalies rest on misunderstandings of the received view or misreadings of model cases of whistleblowing, for example, the Challenger disaster and the Ford Pinto. Nevertheless, the Complicity Theory is important for as in science the contrast with alternative competing accounts often helps us better understand the received view. Several aspects of the received view are reviewed and strengthened through comparison with Complicity Theory, including why whistleblowing needs moral justification. Complicity Theory is also critiqued. The fundamental failure of Complicity Theory is its failure to explain why government and the public encourage and protect whistleblowers despite the possibility of considerable harm to the relevant company in reputation, lost jobs, and lost shareholder value.
Section 2: Corrosion and failure analysis studies in support of the pulp and paper industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keiser, J.R.; Pawel, S.J.; Swindeman, R.W.
1997-04-01
Technical support is being provided to various pulp and paper companies and related industries to help determine the cause of material degradation problems and to identify alternate materials to prevent such degradation. During the past year, examinations have included parts from several sootblowers, two failed economizer tubes, and inspection of a continuous digester. The results of the analyses and inspections were communicated to the plant operators, and, in some cases, recommendations were made. This article discusses examination of sootblower nozzles, which evidenced intergranular cracking. Analysis indicated the presence of chromium carbide precipitates along the grain boundaries, which can cause themore » sample to be sensitized to grain boundary attack.« less
Kurz, Sascha; Pieroh, Philipp; Lenk, Maximilian; Josten, Christoph; Böhme, Jörg
2017-01-01
Abstract Rationale: Pelvic malunion is a rare complication and is technically challenging to correct owing to the complex three-dimensional (3D) geometry of the pelvic girdle. Hence, precise preoperative planning is required to ensure appropriate correction. Reconstructive surgery is generally a 2- or 3-stage procedure, with transiliac osteotomy serving as an alternative to address limb length discrepancy. Patient concerns: A 38-year-old female patient with a Mears type IV pelvic malunion with previous failed reconstructive surgery was admitted to our department due to progressive immobilization, increasing pain especially at the posterior pelvic arch and a leg length discrepancy. The leg discrepancy was approximately 4 cm and rotation of the right hip joint was associated with pain. Diagnosis: Radiography and computer tomography (CT) revealed a hypertrophic malunion at the site of the previous posterior osteotomy (Mears type IV) involving the anterior and middle column, according to the 3-column concept, as well as malunion of the left anterior arch (Mears type IV). Interventions: The surgery was planned virtually via 3D reconstruction, using the patient's CT, and subsequently performed via transiliac osteotomy and symphysiotomy. Finite element method (FEM) was used to plan the osteotomy and osteosynthesis as to include an estimation of the risk of implant failure. Outcomes: There was not incidence of neurological injury or infection, and the remaining leg length discrepancy was ≤ 2 cm. The patient recovered independent, pain free, mobility. Virtual 3D planning provided a more precise measurement of correction parameters than radiographic-based measurements. FEM analysis identified the highest risk for implant failure at the symphyseal plate osteosynthesis and the parasymphyseal screws. No implant failure was observed. Lessons: Transiliac osteotomy, with additional osteotomy or symphysiotomy, was a suitable surgical procedure for the correction of pelvic malunion and provided adequate correction of leg length discrepancy. Virtual 3D planning enabled precise determination of correction parameters, with FEM analysis providing an appropriate method to predict areas of implant failure. PMID:29049196
Gupta, Ashish; Fu, Pingfu; Hashem, Hasan; Vatsayan, Anant; Shein, Steven; Dalal, Jignesh
2017-12-01
Aplastic anemia is a bone marrow failure syndrome with high mortality affecting children and young adults. Although current treatment guidelines recommend hematopoietic stem cell transplant (HCT) for patients with matched sibling donors, outcomes with alternate donor options have been improving. We analyzed a validated multiinstitutional pediatric cohort using one of the largest pediatric and young adult database, the Pediatric Health Information System, for patients diagnosed with aplastic anemia (AA) from 2006 to 2015. Outcomes with upfront and salvage transplants were analyzed along with healthcare utilization. Among 2,169 patients in the study period, almost 20% underwent HCT, while others received immunosuppressive therapy. In a multivariate model, there was no significant difference in mortality with upfront or salvage transplants (odds ratio [OR] 1.24, 95% confidence interval [CI] 0.6-2.58, P = 0.567), while every platelet transfusion was associated with higher mortality (OR 1.37, 95% CI 1.12-1.67, P = 0.002). Healthcare utilization was significantly higher in salvage transplants requiring frequent hospitalization and transfusion requirements. Treatment mortality and graft failure rates were significantly reduced in the salvage transplant group in recent years (2011-2015 as compared to 2006-2010). As outcomes with HCT continue to improve in severe AA, transplant with good alternate donors should be considered upfront in children and young adults. © 2017 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Lagana-Riordan, Christine; Aguilar, Jemel P.; Franklin, Cynthia; Streeter, Calvin L.; Kim, Johnny S.; Tripodi, Stephen J.; Hopson, Laura M.
2011-01-01
Recent trends in education have drawn attention to students at risk of school failure and dropout in the United States. Alternative schools are one method for preventing the severe and long-lasting consequences of underachievement and dropout. Few research studies have sought the opinions and perceptions of the at-risk students who attend…
ERIC Educational Resources Information Center
Vecchio, Jennifer; Kearney, Christopher A.
2009-01-01
Selective mutism is a severe childhood disorder involving failure to speak in public situations in which speaking is expected. The present study examined 9 youths with selective mutism treated with child-focused, exposure-based practices and parent-focused contingency management via an alternating treatments design. Broadband measures of…
Education and Day Treatment Opportunities in Schools: Strategies that Work
ERIC Educational Resources Information Center
Hughes, Anne Fitzsimons; Adera, Beatrice
2006-01-01
In recent years, the number of alternative schools has continued to grow and an increasingly large number of students at-risk for school failure have been enrolled in alternative settings. Critics blame this increase on the fact that the school-aged population has become increasingly diverse, presenting a broad range of issues that the schools…
ERIC Educational Resources Information Center
Long, Anna C. J.; Sanetti, Lisa M. Hagermoser; Lark, Catherine R.; Connolly, Jennifer J. G.
2018-01-01
Students who demonstrate the most challenging behaviors are at risk of school failure and are often placed in alternative schools, in which a primary goal is remediating behavioral and academic concerns to facilitate students' return to their community school. Consistently implemented evidence-based classroom management is necessary toward this…
ERIC Educational Resources Information Center
Gurung, Binod
2013-01-01
Alternative high school students are the at-risk students of educational failure lacking behavioral, emotional, and cognitive engagement with school and the schoolwork. They are also generally considered as the at-risk computer users, who use technology for development of skills and drill and practice when compared to their regular counterparts,…
ERIC Educational Resources Information Center
Goldberg, Steven S.
1989-01-01
A federal statute provided that parents may use the judicial process to challenge educators' decisions. Describes the intent of legalization; how reaction to an adversarial system led to the use of mediation in most states; and why this alternative model is not appropriate for resolving education questions. (MLF)
A Model of Risk Analysis in Analytical Methodology for Biopharmaceutical Quality Control.
Andrade, Cleyton Lage; Herrera, Miguel Angel De La O; Lemes, Elezer Monte Blanco
2018-01-01
One key quality control parameter for biopharmaceutical products is the analysis of residual cellular DNA. To determine small amounts of DNA (around 100 pg) that may be in a biologically derived drug substance, an analytical method should be sensitive, robust, reliable, and accurate. In principle, three techniques have the ability to measure residual cellular DNA: radioactive dot-blot, a type of hybridization; threshold analysis; and quantitative polymerase chain reaction. Quality risk management is a systematic process for evaluating, controlling, and reporting of risks that may affects method capabilities and supports a scientific and practical approach to decision making. This paper evaluates, by quality risk management, an alternative approach to assessing the performance risks associated with quality control methods used with biopharmaceuticals, using the tool hazard analysis and critical control points. This tool provides the possibility to find the steps in an analytical procedure with higher impact on method performance. By applying these principles to DNA analysis methods, we conclude that the radioactive dot-blot assay has the largest number of critical control points, followed by quantitative polymerase chain reaction, and threshold analysis. From the analysis of hazards (i.e., points of method failure) and the associated method procedure critical control points, we conclude that the analytical methodology with the lowest risk for performance failure for residual cellular DNA testing is quantitative polymerase chain reaction. LAY ABSTRACT: In order to mitigate the risk of adverse events by residual cellular DNA that is not completely cleared from downstream production processes, regulatory agencies have required the industry to guarantee a very low level of DNA in biologically derived pharmaceutical products. The technique historically used was radioactive blot hybridization. However, the technique is a challenging method to implement in a quality control laboratory: It is laborious, time consuming, semi-quantitative, and requires a radioisotope. Along with dot-blot hybridization, two alternatives techniques were evaluated: threshold analysis and quantitative polymerase chain reaction. Quality risk management tools were applied to compare the techniques, taking into account the uncertainties, the possibility of circumstances or future events, and their effects upon method performance. By illustrating the application of these tools with DNA methods, we provide an example of how they can be used to support a scientific and practical approach to decision making and can assess and manage method performance risk using such tools. This paper discusses, considering the principles of quality risk management, an additional approach to the development and selection of analytical quality control methods using the risk analysis tool hazard analysis and critical control points. This tool provides the possibility to find the method procedural steps with higher impact on method reliability (called critical control points). Our model concluded that the radioactive dot-blot assay has the larger number of critical control points, followed by quantitative polymerase chain reaction and threshold analysis. Quantitative polymerase chain reaction is shown to be the better alternative analytical methodology in residual cellular DNA analysis. © PDA, Inc. 2018.
ERIC Educational Resources Information Center
Fific, Mario; Townsend, James T.
2010-01-01
Failure to selectively attend to a facial feature, in the part-to-whole paradigm, has been taken as evidence of holistic perception in a large body of face perception literature. In this article, we demonstrate that although failure of selective attention is a necessary property of holistic perception, its presence alone is not sufficient to…
Respiratory failure due to tracheobronchomalacia.
Collard, P.; Freitag, L.; Reynaert, M. S.; Rodenstein, D. O.; Francis, C.
1996-01-01
A case is described of tracheobronchomegaly progressing to extensive tracheomalacia, complicated by episodic choking, recurrent pulmonary infections, and irreversible hypercapnic respiratory failure. A Y-shaped tracheobronchial stent was placed endoscopically to splint the trachea open, with excellent clinical and physiological improvement. New stent designs may provide long term palliation in selected cases of diffuse tracheal collapse or stenosis, and offer an alternative to surgical repair. PMID:8711665
Translational Control in Bone Marrow Failure
2015-05-01
HCLS1 associated protein X-1 (HAX1), cause hereditary forms of neutropenia . Previously, competing hypotheses have posited that mutant forms of...derived induced pluripotent stem cell (iPSC) model of ELANE-associated neutropenia . During the second year of this project, in order to facilitate...pathology. 3 2. KEY WORDS neutropenia bone marrow failure neutrophil elastase ELANE HAX1 alternate translation induced pluripotent stem cells (iPSC
Failure of geometric electromagnetism in the adiabatic vector Kepler problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anglin, J.R.; Schmiedmayer, J.
2004-02-01
The magnetic moment of a particle orbiting a straight current-carrying wire may precess rapidly enough in the wire's magnetic field to justify an adiabatic approximation, eliminating the rapid time dependence of the magnetic moment and leaving only the particle position as a slow degree of freedom. To zeroth order in the adiabatic expansion, the orbits of the particle in the plane perpendicular to the wire are Keplerian ellipses. Higher-order postadiabatic corrections make the orbits precess, but recent analysis of this 'vector Kepler problem' has shown that the effective Hamiltonian incorporating a postadiabatic scalar potential ('geometric electromagnetism') fails to predict themore » precession correctly, while a heuristic alternative succeeds. In this paper we resolve the apparent failure of the postadiabatic approximation, by pointing out that the correct second-order analysis produces a third Hamiltonian, in which geometric electromagnetism is supplemented by a tensor potential. The heuristic Hamiltonian of Schmiedmayer and Scrinzi is then shown to be a canonical transformation of the correct adiabatic Hamiltonian, to second order. The transformation has the important advantage of removing a 1/r{sup 3} singularity which is an artifact of the adiabatic approximation.« less
Score tests for independence in semiparametric competing risks models.
Saïd, Mériem; Ghazzali, Nadia; Rivest, Louis-Paul
2009-12-01
A popular model for competing risks postulates the existence of a latent unobserved failure time for each risk. Assuming that these underlying failure times are independent is attractive since it allows standard statistical tools for right-censored lifetime data to be used in the analysis. This paper proposes simple independence score tests for the validity of this assumption when the individual risks are modeled using semiparametric proportional hazards regressions. It assumes that covariates are available, making the model identifiable. The score tests are derived for alternatives that specify that copulas are responsible for a possible dependency between the competing risks. The test statistics are constructed by adding to the partial likelihoods for the individual risks an explanatory variable for the dependency between the risks. A variance estimator is derived by writing the score function and the Fisher information matrix for the marginal models as stochastic integrals. Pitman efficiencies are used to compare test statistics. A simulation study and a numerical example illustrate the methodology proposed in this paper.
... overdose, there is a very good chance of recovery. However, without rapid treatment, a very large overdose of acetaminophen can lead to liver failure and death in a few days. Alternative Names ...
ERIC Educational Resources Information Center
Garces, Andres; Sanchez-Barba, Luis Fernando
2011-01-01
We describe an alternative educational approach for an inorganic chemistry laboratory module named "Experimentation in Chemistry", which is included in Industrial Engineering and Chemical Engineering courses. The main aims of the new approach were to reduce the high levels of failure and dropout on the module and to make the content match the…
Casey, William J; Rebecca, Alanna M; Smith, Anthony A; Craft, Randall O; Buchel, Edward W
2007-01-01
The internal mammary and thoracodorsal vessels are the standard recipient sites in microsurgical breast reconstruction. We review our series of venous outflow alternatives when these vessels are inadequate or unusable. A retrospective review of all free breast reconstructions was performed from July 2003 through December 2005. Outcomes were measured with regard to re-exploration, flap failure, and fat necrosis, with attention to the timing and side of reconstruction, as well as the presence or absence of radiation therapy. A total of 141 free breast reconstructions were performed during the study period. In seven cases (5%), alternative venous outflow vessels were selected (cephalic or external jugular vein). Nine anastamotic complications occurred, all of which involved the left internal mammary group (statistically significant for venous thrombosis, P = 0.0063) and three flaps failed. All cephalic and external jugular veins remained patent with no flap failures or fat necrosis within this group. The cephalic vein and external jugular vein are excellent alternatives for venous outflow in free breast reconstruction if neither the internal mammary nor thoracodorsal veins are sufficient, especially in left-sided reconstruction. 2007 Wiley-Liss, Inc.
Lee, Charlotte A; Sinha, Siddharth; Fitzpatrick, Emer; Dhawan, Anil
2018-06-01
Human hepatocyte transplantation has been actively perused as an alternative to liver replacement for acute liver failure and liver-based metabolic defects. Current challenges in this field include a limited cell source, reduced cell viability following cryopreservation and poor engraftment of cells into the recipient liver with consequent limited life span. As a result, alternative stem cell sources such as pluripotent stem cells, fibroblasts, hepatic progenitor cells, amniotic epithelial cells and mesenchymal stem/stromal cells (MSCs) can be used to generate induced hepatocyte like cells (HLC) with each technique exhibiting advantages and disadvantages. HLCs may have comparable function to primary human hepatocytes and could offer patient-specific treatment. However, long-term functionality of transplanted HLCs and the potential oncogenic risks of using stem cells have yet to be established. The immunomodulatory effects of MSCs are promising, and multiple clinical trials are investigating their effect in cirrhosis and acute liver failure. Here, we review the current status of hepatocyte transplantation, alternative cell sources to primary human hepatocytes and their potential in liver regeneration. We also describe recent clinical trials using hepatocytes derived from stem cells and their role in improving the phenotype of several liver diseases.
Diagnostic tolerance for missing sensor data
NASA Technical Reports Server (NTRS)
Scarl, Ethan A.
1989-01-01
For practical automated diagnostic systems to continue functioning after failure, they must not only be able to diagnose sensor failures but also be able to tolerate the absence of data from the faulty sensors. It is shown that conventional (associational) diagnostic methods will have combinatoric problems when trying to isolate faulty sensors, even if they adequately diagnose other components. Moreover, attempts to extend the operation of diagnostic capability past sensor failure will necessarily compound those difficulties. Model-based reasoning offers a structured alternative that has no special problems diagnosing faulty sensors and can operate gracefully when sensor data is missing.
The SAM framework: modeling the effects of management factors on human behavior in risk analysis.
Murphy, D M; Paté-Cornell, M E
1996-08-01
Complex engineered systems, such as nuclear reactors and chemical plants, have the potential for catastrophic failure with disastrous consequences. In recent years, human and management factors have been recognized as frequent root causes of major failures in such systems. However, classical probabilistic risk analysis (PRA) techniques do not account for the underlying causes of these errors because they focus on the physical system and do not explicitly address the link between components' performance and organizational factors. This paper describes a general approach for addressing the human and management causes of system failure, called the SAM (System-Action-Management) framework. Beginning with a quantitative risk model of the physical system, SAM expands the scope of analysis to incorporate first the decisions and actions of individuals that affect the physical system. SAM then links management factors (incentives, training, policies and procedures, selection criteria, etc.) to those decisions and actions. The focus of this paper is on four quantitative models of action that describe this last relationship. These models address the formation of intentions for action and their execution as a function of the organizational environment. Intention formation is described by three alternative models: a rational model, a bounded rationality model, and a rule-based model. The execution of intentions is then modeled separately. These four models are designed to assess the probabilities of individual actions from the perspective of management, thus reflecting the uncertainties inherent to human behavior. The SAM framework is illustrated for a hypothetical case of hazardous materials transportation. This framework can be used as a tool to increase the safety and reliability of complex technical systems by modifying the organization, rather than, or in addition to, re-designing the physical system.
Analysis of recreational closed-circuit rebreather deaths 1998-2010.
Fock, Andrew W
2013-06-01
Since the introduction of recreational closed-circuit rebreathers (CCRs) in 1998, there have been many recorded deaths. Rebreather deaths have been quoted to be as high as 1 in 100 users. Rebreather fatalities between 1998 and 2010 were extracted from the Deeplife rebreather mortality database, and inaccuracies were corrected where known. Rebreather absolute numbers were derived from industry discussions and training agency statistics. Relative numbers and brands were extracted from the Rebreather World website database and a Dutch rebreather survey. Mortality was compared with data from other databases. A fault-tree analysis of rebreathers was compared to that of open-circuit scuba of various configurations. Finally, a risk analysis was applied to the mortality database. The 181 recorded recreational rebreather deaths occurred at about 10 times the rate of deaths amongst open-circuit recreational scuba divers. No particular brand or type of rebreather was over-represented. Closed-circuit rebreathers have a 25-fold increased risk of component failure compared to a manifolded twin-cylinder open-circuit system. This risk can be offset by carrying a redundant 'bailout' system. Two-thirds of fatal dives were associated with a high-risk dive or high-risk behaviour. There are multiple points in the human-machine interface (HMI) during the use of rebreathers that can result in errors that may lead to a fatality. While rebreathers have an intrinsically higher risk of mechanical failure as a result of their complexity, this can be offset by good design incorporating redundancy and by carrying adequate 'bailout' or alternative gas sources for decompression in the event of a failure. Designs that minimize the chances of HMI errors and training that highlights this area may help to minimize fatalities.
NASA Astrophysics Data System (ADS)
Ryan, R.; Gross, L. A.
1995-05-01
The Space Shuttle main engine (SSME) alternate high-pressure liquid oxygen pump experienced synchronous vibration and ball bearing life problems that were program threatening. The success of the program hinged on the ability to solve these development problems. The design and solutions to these problems are engirded in the lessons learned and experiences from prior programs, technology programs, and the ability to properly conduct failure or anomaly investigations. The failure investigation determines the problem cause and is the basis for recommending design solutions. For a complex problem, a comprehensive solution requires that formal investigation procedures be used, including fault trees, resolution logic, and action items worked through a concurrent engineering-multidiscipline team. The normal tendency to use an intuitive, cut-and-try approach will usually prove to be costly, both in money and time and will reach a less than optimum, poorly understood answer. The SSME alternate high-pressure oxidizer turbopump development has had two complex problems critical to program success: (1) high synchronous vibrations and (2) excessive ball bearing wear. This paper will use these two problems as examples of this formal failure investigation approach. The results of the team's investigation provides insight into the complexity of the turbomachinery technical discipline interacting/sensitivities and the fine balance of competing investigations required to solve problems and guarantee program success. It is very important to the solution process that maximum use be made of the resources that both the contractor and Government can bring to the problem in a supporting and noncompeting way. There is no place for the not-invented-here attitude. The resources include, but are not limited to: (1) specially skilled professionals; (2) supporting technologies; (3) computational codes and capabilities; and (4) test and manufacturing facilities.
NASA Technical Reports Server (NTRS)
Ryan, R.; Gross, L. A.
1995-01-01
The Space Shuttle main engine (SSME) alternate high-pressure liquid oxygen pump experienced synchronous vibration and ball bearing life problems that were program threatening. The success of the program hinged on the ability to solve these development problems. The design and solutions to these problems are engirded in the lessons learned and experiences from prior programs, technology programs, and the ability to properly conduct failure or anomaly investigations. The failure investigation determines the problem cause and is the basis for recommending design solutions. For a complex problem, a comprehensive solution requires that formal investigation procedures be used, including fault trees, resolution logic, and action items worked through a concurrent engineering-multidiscipline team. The normal tendency to use an intuitive, cut-and-try approach will usually prove to be costly, both in money and time and will reach a less than optimum, poorly understood answer. The SSME alternate high-pressure oxidizer turbopump development has had two complex problems critical to program success: (1) high synchronous vibrations and (2) excessive ball bearing wear. This paper will use these two problems as examples of this formal failure investigation approach. The results of the team's investigation provides insight into the complexity of the turbomachinery technical discipline interacting/sensitivities and the fine balance of competing investigations required to solve problems and guarantee program success. It is very important to the solution process that maximum use be made of the resources that both the contractor and Government can bring to the problem in a supporting and noncompeting way. There is no place for the not-invented-here attitude. The resources include, but are not limited to: (1) specially skilled professionals; (2) supporting technologies; (3) computational codes and capabilities; and (4) test and manufacturing facilities.
Combining neuroendocrine inhibitors in heart failure: reflections on safety and efficacy.
Jneid, Hani; Moukarbel, George V; Dawson, Bart; Hajjar, Roger J; Francis, Gary S
2007-12-01
Neuroendocrine activation in heart failure has become the major target of pharmacotherapy for this growing epidemic. Agents targeting the renin-angiotensin-aldosterone and sympathetic nervous systems have shown cardiovascular and survival benefits in clinical trials. Beta-blockers and angiotensin-converting enzyme (ACE) inhibitors remain the mainstream initial therapy. The benefits of aldosterone antagonists have been demonstrated in advanced heart failure (spironolactone) and after myocardial infarction complicated by left ventricular dysfunction and heart failure (eplerenone). Emerging clinical evidence demonstrated that angiotensin receptor blockers may be a reasonable alternative to ACE inhibitors in patients with heart failure (candesartan) and following myocardial infarction complicated by heart failure or left ventricular dysfunction (valsartan). Angiotensin receptor blockers (candesartan) also provided incremental benefits when added to ACE inhibitors in chronic heart failure. Thus, combining neuroendocrine inhibitors in heart failure appears both biologically plausible and evidence-based. However, this approach raised concerns about side effects, such as hypotension, renal insufficiency, hyperkalemia, and others. Close follow-up and implementation of evidence-based medicine (ie, using agents and doses proven beneficial in clinical trials) should therefore be undertaken when combining neuroendocrine inhibitors.
Time of non-invasive ventilation.
Nava, Stefano; Navalesi, Paolo; Conti, Giorgio
2006-03-01
Non-invasive ventilation (NIV) is a safe, versatile and effective technique that can avert side effects and complications associated with endotracheal intubation. The success of NIV relies on several factors, including the type and severity of acute respiratory failure, the underlying disease, the location of treatment, and the experience of the team. The time factor is also important. NIV is primarily used to avert the need for endotracheal intubation in patients with early-stage acute respiratory failure and post-extubation respiratory failure. It can also be used as an alternative to invasive ventilation at a more advanced stage of acute respiratory failure or to facilitate the process of weaning from mechanical ventilation. NIV has been used to prevent development of acute respiratory failure or post-extubation respiratory failure. The number of days of NIV and hours of daily use differ, depending on the severity and course of the acute respiratory failure and the timing of application. In this review article, we analyse, compare and discuss the results of studies in which NIV was applied at various times during the evolution of acute respiratory failure.
Finite element investigation of the effect of a bifid arch on loading of the vertebral isthmus.
Quah, Conal; Yeoman, Mark S; Cizinauskas, Andrius; Cooper, Kevin C; Peirce, Nick S; McNally, Donal S; Boszczyk, Bronek M
2014-04-01
The biomechanical effect of a bifid arch as seen in spina bifida occulta and following a midline laminectomy is poorly understood. To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Finite element analysis. Finite element model of an intact L4-S1 human lumbar motion segment including ligaments was used. A section of the L5 vertebral arch and spinous process was removed to create the model with a midline defect. The models were loaded axially to 1 kN and then combined with axial rotation of 3°. Bilateral stresses, alternating stresses, and shear fatigue failure on both models were assessed and compared. Under 1 kN axial load, the von Mises stresses observed in midline defect case and in the intact case were very similar (differences <5 MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1 kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the midline defect case (31 MPa) was much higher than the intact case (24.2 MPa), indicating a lack of load sharing across the vertebral arch in the midline defect case. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the midline defect case and 13.6 MPa for the intact case. From this, it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load and rotation conditions in the midline defect case, whereas for the intact case, fatigue failure will occur only after more than 10 million cycles. A bifid arch predisposes the isthmus to early fatigue fracture by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Copyright © 2014 Elsevier Inc. All rights reserved.
Li, Ling; Li, Sheyu; Liu, Jiali; Deng, Ke; Busse, Jason W; Vandvik, Per Olav; Wong, Evelyn; Sohani, Zahra N; Bala, Malgorzata M; Rios, Lorena P; Malaga, German; Ebrahim, Shanil; Shen, Jiantong; Zhang, Longhao; Zhao, Pujing; Chen, Qunfei; Wang, Yingqiang; Guyatt, Gordon H; Sun, Xin
2016-05-11
The effect of glucagon-like peptide-1(GLP-1) receptor agonists on heart failure remains uncertain. We therefore conducted a systematic review to assess the possible impact of GLP-1 agonists on heart failure or hospitalization for heart failure in patients with type 2 diabetes. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL) and ClinicalTrials.gov to identify randomized controlled trials (RCTs) and observational studies that addressed the effect of GLP-1 receptor agonists in adults with type 2 diabetes, and explicitly reported heart failure or hospitalization for heart failure. Two paired reviewers screened reports, collected data, and assessed the risk of bias. We pooled data from RCTs and observational studies separately, and used the GRADE approach to rate the quality of evidence. We identified 25 studies that were eligible for our review; 21 RCTs (n = 18,270) and 4 observational studies (n = 111,029). Low quality evidence from 20 RCTs suggested, if anything, a lower incidence of heart failure between GLP-1 agonists versus control (17/7,441 vs. 19/4,317; odds ratio (OR) 0.62, 95 % confidence interval (CI) 0.31 to 1.22; risk difference (RD) 19 fewer, 95 % CI 34 fewer to 11 more per 1000 over 5 years). Three cohort studies comparing GLP-1 agonists to alternative agents provided very low quality evidence that GLP-1 agonists do not increase the incidence of heart failure. One RCT provided moderate quality evidence that GLP-1 agonists were not associated with hospitalization for heart failure (lixisenatide vs placebo: 122/3,034 vs. 127/3,034; adjusted hazard ratio 0.96, 95 % CI 0.75 to 1.23; RD 4 fewer, 95 % CI 25 fewer to 23 more per 1000 over 5 years) and a case-control study provided very low quality evidence also suggesting no association (GLP-1 agonists vs. other anti-hyperglycemic drugs: 1118 cases and 17,626 controls, adjusted OR 0.67, 95 % CI 0.32 to 1.42). The current evidence suggests that GLP-1 agonists do not increase the risk of heart failure or hospitalization for heart failure among patients with type 2 diabetes.
Cycles till failure of silver-zinc cells with competing failure modes - Preliminary data analysis
NASA Technical Reports Server (NTRS)
Sidik, S. M.; Leibecki, H. F.; Bozek, J. M.
1980-01-01
The data analysis of cycles to failure of silver-zinc electrochemical cells with competing failure modes is presented. The test ran 129 cells through charge-discharge cycles until failure; preliminary data analysis consisted of response surface estimate of life. Batteries fail through low voltage condition and an internal shorting condition; a competing failure modes analysis was made using maximum likelihood estimation for the extreme value life distribution. Extensive residual plotting and probability plotting were used to verify data quality and selection of model.
NASA Astrophysics Data System (ADS)
Rahman, P. A.; D'K Novikova Freyre Shavier, G.
2018-03-01
This scientific paper is devoted to the analysis of the mean time to data loss of redundant disk arrays RAID-6 with alternation of data considering different failure rates of disks both in normal state of the disk array and in degraded and rebuild states, and also nonzero time of the disk replacement. The reliability model developed by the authors on the basis of the Markov chain and obtained calculation formula for estimation of the mean time to data loss (MTTDL) of the RAID-6 disk arrays are also presented. At last, the technique of estimation of the initial reliability parameters and examples of calculation of the MTTDL of the RAID-6 disk arrays for the different numbers of disks are also given.
30 CFR 285.817-285.819 - [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
... Equipment Failure and Adverse Environmental Effects §§ 285.817-285.819 [Reserved] Inspections and... ENERGY ALTERNATE USES OF EXISTING FACILITIES ON THE OUTER CONTINENTAL SHELF Environmental and Safety...
Study on coming out of the shaft from ceramic sleeve in terms of the residual displacement
NASA Astrophysics Data System (ADS)
Zhang, G. W.; Noda, N.-A.; Sano, Y.; Sakai, H.
2018-06-01
Ceramic roller can be used in the heating furnace conveniently because of its high temperature resistance. However, the coming out of the shaft may often happen from the ceramic sleeve under repeated load. In this paper, a two-dimensional shrink fitted structure is considered by replacing the shaft with the inner plate and by replacing the sleeve with the outer plate. Based on the model with stopper, the FEM simulation is performed under alternate loading with certain intervals newly added. The analysis results show that the coming out failure can be explained from the residual displacement accumulation during these intervals.
Failure Analysis of Discrete Damaged Tailored Extension-Shear-Coupled Stiffened Composite Panels
NASA Technical Reports Server (NTRS)
Baker, Donald J.
2005-01-01
The results of an analytical and experimental investigation of the failure of composite is tiffener panels with extension-shear coupling are presented. This tailored concept, when used in the cover skins of a tiltrotor aircraft wing has the potential for increasing the aeroelastic stability margins and improving the aircraft productivity. The extension-shear coupling is achieved by using unbalanced 45 plies in the skin. The failure analysis of two tailored panel configurations that have the center stringer and adjacent skin severed is presented. Finite element analysis of the damaged panels was conducted using STAGS (STructural Analysis of General Shells) general purpose finite element program that includes a progressive failure capability for laminated composite structures that is based on point-stress analysis, traditional failure criteria, and ply discounting for material degradation. The progressive failure predicted the path of the failure and maximum load capability. There is less than 12 percent difference between the predicted failure load and experimental failure load. There is a good match of the panel stiffness and strength between the progressive failure analysis and the experimental results. The results indicate that the tailored concept would be feasible to use in the wing skin of a tiltrotor aircraft.
A large landslide in volcanic rock: failure processes, geometry and propagation
NASA Astrophysics Data System (ADS)
Putu Krishna Wijaya, I.; Zangerl, Christian; Straka, Wolfgang; Mergili, Martin; Prasad Pudasaini, Shiva; Arifianti, Yukni
2017-04-01
The Jemblung landslide in Banjarnegara, Indonesia was one of the most destructive landslides in the country since 2006. This landslide caused at least 90 deaths while more than 1300 people were evacuated to safer areas. Concerning the failure mechanisms and type of material, the event can be characterized as a complex landslide (earth slide to earth flow). It originated in volcaniclastic soil/rock, i.e. andesites and lapilli-tuffs of varying degrees of weathering that lie above tuffaceous sandstones, conglomerates, as well as an alternation of shale and brown coal layers. Unmanned aerial vehicle (UAV) data from a secondary database are processed by using photogrammetric software to obtain an overview of the landslide geometry before and after the failure event. Stratigraphic field data and geoelectrical measurements are compared and correlated to build a geological-geometrical model and to estimate the volume of the landslide. Petrographical and XRD analysis are conducted to explain the mineral composition of parent rock and its weathering products. Rainfall as well as seismologic data are collected to study potential trigger and failure mechanisms. The geological-geometrical model of the landslide, digital terrain models of the process area and geotechnical soil properties are combined to model the initial sliding process by applying limit-equilibrium software products. Furthermore, the landslide propagation is simulated with the novel, GIS-based, two-phase mass flow modelling tool r.avaflow in order to improve the understanding of the dynamics of the Jemblung landslide.
New Approach For Prediction Groundwater Depletion
NASA Astrophysics Data System (ADS)
Moustafa, Mahmoud
2017-01-01
Current approaches to quantify groundwater depletion involve water balance and satellite gravity. However, the water balance technique includes uncertain estimation of parameters such as evapotranspiration and runoff. The satellite method consumes time and effort. The work reported in this paper proposes using failure theory in a novel way to predict groundwater saturated thickness depletion. An important issue in the failure theory proposed is to determine the failure point (depletion case). The proposed technique uses depth of water as the net result of recharge/discharge processes in the aquifer to calculate remaining saturated thickness resulting from the applied pumping rates in an area to evaluate the groundwater depletion. Two parameters, the Weibull function and Bayes analysis were used to model and analyze collected data from 1962 to 2009. The proposed methodology was tested in a nonrenewable aquifer, with no recharge. Consequently, the continuous decline in water depth has been the main criterion used to estimate the depletion. The value of the proposed approach is to predict the probable effect of the current applied pumping rates on the saturated thickness based on the remaining saturated thickness data. The limitation of the suggested approach is that it assumes the applied management practices are constant during the prediction period. The study predicted that after 300 years there would be an 80% probability of the saturated aquifer which would be expected to be depleted. Lifetime or failure theory can give a simple alternative way to predict the remaining saturated thickness depletion with no time-consuming processes such as the sophisticated software required.
Olivieri, Jacopo; Attolico, Immacolata; Nuccorini, Roberta; Pascale, Sara Pasquina; Chiarucci, Martina; Poiani, Monica; Corradini, Paolo; Farina, Lucia; Gaidano, Gianluca; Nassi, Luca; Sica, Simona; Piccirillo, Nicola; Pioltelli, Pietro Enrico; Martino, Massimo; Moscato, Tiziana; Pini, Massimo; Zallio, Francesco; Ciceri, Fabio; Marktel, Sarah; Mengarelli, Andrea; Musto, Pellegrino; Capria, Saveria; Merli, Francesco; Codeluppi, Katia; Mele, Giuseppe; Lanza, Francesco; Specchia, Giorgina; Pastore, Domenico; Milone, Giuseppe; Saraceni, Francesco; Di Nardo, Elvira; Perseghin, Paolo; Olivieri, Attilio
2018-04-01
Predicting mobilization failure before it starts may enable patient-tailored strategies. Although consensus criteria for predicted PM (pPM) are available, their predictive performance has never been measured on real data. We retrospectively collected and analyzed 1318 mobilization procedures performed for MM and lymphoma patients in the plerixafor era. In our sample, 180/1318 (13.7%) were PM. The score resulting from published pPM criteria had sufficient performance for predicting PM, as measured by AUC (0.67, 95%CI: 0.63-0.72). We developed a new prediction model from multivariate analysis whose score (pPM-score) resulted in better AUC (0.80, 95%CI: 0.76-0.84, p < 0001). pPM-score included as risk factors: increasing age, diagnosis of NHL, positive bone marrow biopsy or cytopenias before mobilization, previous mobilization failure, priming strategy with G-CSF alone, or without upfront plerixafor. A simplified version of pPM-score was categorized using a cut-off to maximize positive likelihood ratio (15.7, 95%CI: 9.9-24.8); specificity was 98% (95%CI: 97-98.7%), sensitivity 31.7% (95%CI: 24.9-39%); positive predictive value in our sample was 71.3% (95%CI: 60-80.8%). Simplified pPM-score can "rule in" patients at very high risk for PM before starting mobilization, allowing changes in clinical management, such as choice of alternative priming strategies, to avoid highly likely mobilization failure.
Simplified technique for auxiliary orthotopic liver transplantation using a whole graft
ROCHA-SANTOS, Vinicius; NACIF, Lucas Souto; PINHEIRO, Rafael Soares; DUCATTI, Liliana; ANDRAUS, Wellington; D'ALBURQUERQUE, Luiz Carneiro
2015-01-01
Background Acute liver failure is associated with a high mortality rate and the main purposes of treatment are to prevent cerebral edema and infections, which often are responsible for patient death. The orthotopic liver transplantation is the gold standard treatment and improves the 1-year survival. Aim To describe an alternative technique to auxiliary liver transplant on acute liver failure. Method Was performed whole auxiliary liver transplantation as an alternative technique for a partial auxiliary liver transplantation using a whole liver graft from a child removing the native right liver performed a right hepatectomy. The patient met the O´Grady´s criteria and the rational to indicate an auxiliary orthotopic liver transplantation was the acute classification without hemodynamic instability or renal failure in a patient with deterioration in consciousness. Results The procedure improved liver function and decreased intracranial hypertension in the postoperative period. Conclusion This technique can overcome some postoperative complications that are associated with partial grafts. As far as is known, this is the first case of auxiliary orthotopic liver transplantation in Brazil. PMID:26176253
Comparing the tensile strength of square and reversing half-hitch alternating post knots
Wu, Vincent; Sykes, Edward A.; Mercer, Dale; Hopman, Wilma M.; Tang, Ephraim
2017-01-01
Background Square knots are the gold standard in hand-tie wound closure, but are difficult to reproduce in deep cavities, inadvertently resulting in slipknots. The reversing half-hitch alternating post (RHAP) knot has been suggested as an alternative owing to its nonslip nature and reproducibility in limited spaces. We explored whether the RHAP knot is noninferior to the square knot by assessing tensile strength. Methods We conducted 10 trials for each baseline and knot configuration, using 3–0 silk and 3–0 polyglactin 910 sutures. We compared tensile strength between knot configurations at the point of knot failure between slippage and breakage. Results Maximal failure strength (mean ± SD) in square knots was reached with 4-throw in both silk (30 ± 1.5 N) and polyglactin 910 (39 ± 12 N). For RHAP knots, maximal failure strength was reached at 5-throw for both silk (31 ± 1.5 N) and polyglactin 910 (41 ± 13 N). In both sutures, there were no strength differences between 3-throw square and 4-throw RHAP, between 4-throw square and 5-throw RHAP, or between 5-throw square and 6-throw RHAP knots. Polyglactin 910 sutures, in all knot configurations, were more prone to slippage than silk sutures (p < 0.001). Conclusion The difference in mean tensile strength could be attributed to the proportion of knot slippage versus breakage, which is material-dependent. Future studies can re-evaluate findings in monofilament sutures and objectively assess the reproducibility of square and RHAP knots in deep cavities. Our results indicate that RHAP knots composed of 1 extra throw provide equivalent strength to square knots and may be an alternative when performing hand-ties in limited cavities with either silk or polyglactin 910 sutures. PMID:28327276
Comparing the tensile strength of square and reversing half-hitch alternating post knots.
Wu, Vincent; Sykes, Edward A; Mercer, Dale; Hopman, Wilma M; Tang, Ephraim
2017-06-01
Square knots are the gold standard in hand-tie wound closure, but are difficult to reproduce in deep cavities, inadvertently resulting in slipknots. The reversing half-hitch alternating post (RHAP) knot has been suggested as an alternative owing to its nonslip nature and reproducibility in limited spaces. We explored whether the RHAP knot is noninferior to the square knot by assessing tensile strength. We conducted 10 trials for each baseline and knot configuration, using 3-0 silk and 3-0 polyglactin 910 sutures. We compared tensile strength between knot configurations at the point of knot failure between slippage and breakage. Maximal failure strength (mean ± SD) in square knots was reached with 4-throw in both silk (30 ± 1.5 N) and polyglactin 910 (39 ± 12 N). For RHAP knots, maximal failure strength was reached at 5-throw for both silk (31 ± 1.5 N) and polyglactin 910 (41 ± 13 N). In both sutures, there were no strength differences between 3-throw square and 4-throw RHAP, between 4-throw square and 5-throw RHAP, or between 5-throw square and 6-throw RHAP knots. Polyglactin 910 sutures, in all knot configurations, were more prone to slippage than silk sutures ( p < 0.001). The difference in mean tensile strength could be attributed to the proportion of knot slippage versus breakage, which is material-dependent. Future studies can re-evaluate findings in monofilament sutures and objectively assess the reproducibility of square and RHAP knots in deep cavities. Our results indicate that RHAP knots composed of 1 extra throw provide equivalent strength to square knots and may be an alternative when performing hand-ties in limited cavities with either silk or polyglactin 910 sutures.
Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.
2010-01-01
An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. PMID:20309731
Identifying Contingency Requirements using Obstacle Analysis on an Unpiloted Aerial Vehicle
NASA Technical Reports Server (NTRS)
Lutz, Robyn R.; Nelson, Stacy; Patterson-Hine, Ann; Frost, Chad R.; Tal, Doron
2005-01-01
This paper describes experience using Obstacle Analysis to identify contingency requirements on an unpiloted aerial vehicle. A contingency is an operational anomaly, and may or may not involve component failure. The challenges to this effort were: ( I ) rapid evolution of the system while operational, (2) incremental autonomy as capabilities were transferred from ground control to software control and (3) the eventual safety-criticality of such systems as they begin to fly over populated areas. The results reported here are preliminary but show that Obstacle Analysis helped (1) identify new contingencies that appeared as autonomy increased; (2) identify new alternatives for handling both previously known and new contingencies; and (3) investigate the continued validity of existing software requirements for contingency handling. Since many mobile, intelligent systems are built using a development process that poses the same challenges, the results appear to have applicability to other similar systems.
1986-11-01
Report Organization. .................... 7 *PART 11: CASE STUDIES .......................... 9 Teton Dam Failure Flood. ...................... 9...channel, (3) Laurel Run Dam , and (4) Stillhouse Hollow Dam . The Laurel Run and Teton case studies involved field data sets from actual dam failures. The...hypothetical prismatic channel case study used the Teton reservoir and dam data but replaced the complex Teton Valley geometry with a prismatic channel
Moise, Pamela A; Culshaw, Darren L; Wong-Beringer, Annie; Bensman, Joyce; Lamp, Kenneth C; Smith, Winter J; Bauer, Karri; Goff, Debra A; Adamson, Robert; Leuthner, Kimberly; Virata, Michael D; McKinnell, James A; Chaudhry, Saira B; Eskandarian, Romic; Lodise, Thomas; Reyes, Katherine; Zervos, Marcus J
2016-01-01
Clinical studies comparing vancomycin with alternative therapy for methicillin-resistant Staphylococcus aureus (MRSA) bacteremia are limited. The objective of this study was to compare outcomes of early daptomycin versus vancomycin treatment for MRSA bacteremia with high vancomycin MICs in a geographically diverse multicenter evaluation. This nationwide, retrospective, multicenter (N = 11), matched, cohort study compared outcomes of early daptomycin with vancomycin for MRSA bloodstream infection (BSI) with vancomycin MICs 1.5 to 2 µg/mL. Matching variables, based on propensity regression analysis, included age, intensive care unit (ICU), and type of BSI. Outcomes were as follows: (1) composite failure (60-day all-cause mortality, 7-day clinical or microbiologic failure, 30-day BSI relapse, or end-of-treatment failure (EOT; discontinue/change daptomycin or vancomycin because of treatment failure or adverse event]); (2) nephrotoxicity; and (2) day 4 BSI clearance. A total of 170 patients were included. The median (interquartile range) age was 60 years (50-74); the median (range) Acute Physiology and Chronic Health Evaluation II score was 15 (10-18); 31% were in an ICU; and 92% had an infectious disease consultation. BSI types included endocarditis/endovascular (39%), extravascular (55%), and central catheter (6%). The median daptomycin dose was 6 mg/kg, and the vancomycin trough level was 17 mg/L. Overall composite failure was 35% (59 of 170): 15% due to 60-day all-cause mortality, 14% for lack of clinical or microbiologic response by 7 days, and 17% due to failure at end of therapy (discontinue/change because of treatment failure or adverse event). Predictors of composite failure according to multivariate analysis were age >60 years (odds ratio, 3.7; P < 0.01) and ICU stay (odds ratio, 2.64; P = 0.03). Notable differences between treatment groups were seen with: (1) end of therapy failure rates (11% vs 24% for daptomycin vs vancomycin; P = 0.025); (2) acute kidney injury rates (9% vs 23% for daptomycin vs vancomycin; P = 0.043); and (3) day 4 bacteremia clearance rates for immunocompromised patients (n = 26) (94% vs 56% for daptomycin vs vancomycin; P = 0.035). Results from this multicenter study provide, for the first time, a geographically diverse evaluation of daptomycin versus vancomycin for patients with vancomycin-susceptible MRSA bacteremia with vancomycin MIC values >1 µg/mL. Although the overall composite failure rates did not differ between the vancomycin and daptomycin groups when intensively matched according to risks for failure, the rates of acute kidney injury were significantly lower in the daptomycin group. These findings suggest that daptomycin is a useful therapy for clinicians treating patients who have MRSA bacteremia. Prospective, randomized trials should be conducted to better assess the potential significance of elevated vancomycin MIC. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.
The future of mechanical circulatory support for advanced heart failure.
Marinescu, Karolina K; Uriel, Nir; Adatya, Sirtaz
2016-05-01
Mechanical circulatory support (MCS) has become the main focus of heart replacement therapy for end stage heart failure patients. Advances in technology are moving towards miniaturization, biventricular support devices, complete internalization, improved hemocompatibility profiles, and responsiveness to cardiac loading conditions. This review will discuss the recent advances and investigational devices in MCS for advanced heart failure. The demand for both short-term and long-term durable devices for advanced heart failure is increasing. The current devices are still fraught with an unacceptably high incidence of gastrointestinal bleeding and thromboembolic and infectious complications. New devices are on the horizon focusing on miniaturization, versatility for biventricular support, improved hemocompatibility, use of alternate energy sources, and incorporation of continuous hemodynamic monitoring. The role for MCS in advanced heart replacement therapy is steadily increasing. With the advent of newer generation devices on the horizon, the potential exists for MCS to surpass heart transplantation as the primary therapy for advanced heart failure.
Vasodilators in Acute Heart Failure: Review of the Latest Studies.
Levy, Phillip D; Laribi, Said; Mebazaa, Alexandre
2014-06-01
Vasodilators play an important role in the management of acute heart failure, particularly when increased afterload is the precipitating cause of decompensation. The time-honored approach to afterload reduction has been largely focused on use of intravenous nitrovasodilators and, when properly dosed, this class of agents does provide substantial symptom relief for patients with acute hypertensive heart failure. Despite this, nitrovasodilators have never been shown to diminish mortality or provide any post-discharge outcome benefit leading to an on-going search for viable and more effective alternatives. While no new vasodilators have been approved for use in acute heart failure since nesiritide more than a decade ago, a number of novel agents have been developed, with some showing significant promise in recent clinical trials. In this review, we summarize the latest study data as it relates to vasodilator therapy and provide a glimpse into the not too distant future state of acute heart failure care.
The Severe Heart Failure Questionnaire: Italian translation and linguistic validation.
Scarinzi, C; Berchialla, P; Ghidina, M; Rozbowsky, P; Pilotto, L; Albanese, M C; Fioretti, P M; Gregori, D
2008-12-01
The quality of life (QoL) is an important outcome indicator for heart failure management. As the use of a validate questionnaire in a different cultural context can affect data interpretation our main objective is the Italian translation and linguistic validation of the Severe Heart Failure Questionnaire (SHF) and its comparison with the MLHF (Minnesota Living with Heart Failure) Questionnaire. The SHF and "The Minnesota Living with Heart Failure Questionnaire" were translated. A consensus involving parallel back-translations was established among a group of cardiologists, psychologists and biostatisticians. SHF and MLHF were both administrated to a sample of 50 patients. The patients' median age was 63 years. Ace inhibitors therapy was administered in 88% of cases and betablockers in 56% of cases. Finally the Italian version of SHF correlates well with MLHF for all domains, except life satisfaction SHF domain. The Italian version of the SHF correlates well with MLHF for almost all domains and it represents a valid alternative for quality of life assessment in heart failure patients.
User-Defined Material Model for Progressive Failure Analysis
NASA Technical Reports Server (NTRS)
Knight, Norman F. Jr.; Reeder, James R. (Technical Monitor)
2006-01-01
An overview of different types of composite material system architectures and a brief review of progressive failure material modeling methods used for structural analysis including failure initiation and material degradation are presented. Different failure initiation criteria and material degradation models are described that define progressive failure formulations. These progressive failure formulations are implemented in a user-defined material model (or UMAT) for use with the ABAQUS/Standard1 nonlinear finite element analysis tool. The failure initiation criteria include the maximum stress criteria, maximum strain criteria, the Tsai-Wu failure polynomial, and the Hashin criteria. The material degradation model is based on the ply-discounting approach where the local material constitutive coefficients are degraded. Applications and extensions of the progressive failure analysis material model address two-dimensional plate and shell finite elements and three-dimensional solid finite elements. Implementation details and use of the UMAT subroutine are described in the present paper. Parametric studies for composite structures are discussed to illustrate the features of the progressive failure modeling methods that have been implemented.
... diuretics Thrombocytosis (high platelet count) Tumors Vitamin A excess Vitamin D excess Lower-than-normal levels may be due to: Hypoparathyroidism Malabsorption Osteomalacia Pancreatitis Renal failure Rickets Vitamin D deficiency Alternative Names Free calcium; Ionized calcium ...
An efficient scan diagnosis methodology according to scan failure mode for yield enhancement
NASA Astrophysics Data System (ADS)
Kim, Jung-Tae; Seo, Nam-Sik; Oh, Ghil-Geun; Kim, Dae-Gue; Lee, Kyu-Taek; Choi, Chi-Young; Kim, InSoo; Min, Hyoung Bok
2008-12-01
Yield has always been a driving consideration during fabrication of modern semiconductor industry. Statistically, the largest portion of wafer yield loss is defective scan failure. This paper presents efficient failure analysis methods for initial yield ramp up and ongoing product with scan diagnosis. Result of our analysis shows that more than 60% of the scan failure dies fall into the category of shift mode in the very deep submicron (VDSM) devices. However, localization of scan shift mode failure is very difficult in comparison to capture mode failure because it is caused by the malfunction of scan chain. Addressing the biggest challenge, we propose the most suitable analysis method according to scan failure mode (capture / shift) for yield enhancement. In the event of capture failure mode, this paper describes the method that integrates scan diagnosis flow and backside probing technology to obtain more accurate candidates. We also describe several unique techniques, such as bulk back-grinding solution, efficient backside probing and signal analysis method. Lastly, we introduce blocked chain analysis algorithm for efficient analysis of shift failure mode. In this paper, we contribute to enhancement of the yield as a result of the combination of two methods. We confirm the failure candidates with physical failure analysis (PFA) method. The direct feedback of the defective visualization is useful to mass-produce devices in a shorter time. The experimental data on mass products show that our method produces average reduction by 13.7% in defective SCAN & SRAM-BIST failure rates and by 18.2% in wafer yield rates.
NASA Technical Reports Server (NTRS)
1974-01-01
Future operational concepts for the space transportation system were studied in terms of space shuttle upper stage failure contingencies possible during deployment, retrieval, or space servicing of automated satellite programs. Problems anticipated during mission planning were isolated using a modified 'fault tree' technique, normally used in safety analyses. A comprehensive space servicing hazard analysis is presented which classifies possible failure modes under the catagories of catastrophic collision, failure to rendezvous and dock, servicing failure, and failure to undock. The failure contingencies defined are to be taken into account during design of the upper stage.
Fixed-angle plate osteosynthesis of the patella - an alternative to tension wiring?
Wild, M; Eichler, C; Thelen, S; Jungbluth, P; Windolf, J; Hakimi, M
2010-05-01
The goal of this study is carry out a biomechanical evaluation of the stability of a bilateral, polyaxial, fixed-angle 2.7 mm plate system specifically designed for use on the patella. The results of this approach are then compared to the two currently most commonly used surgical techniques for patella fractures: modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring. A transient biomechanical analysis determining material failure points of all osteosyntheses were conducted on 21 identical left polyurethane foam patellae, which were osteotomized horizontally. Evaluated were load (N), displacement (mm) and run-time (s) as well as elastic modulus (MPa), tensile strength (MPa) and strain at failure (%). With a maximum load capacity of 2396 (SD 492) N, the fixed-angle plate proved to be significantly stronger than the cannulated lag screws with anterior tension wiring (1015 (SD 246) N) and the modified anterior tension wiring (625 (SD 84.9) N). The fixed-angle plate displayed significantly greater stiffness and lower fracture gap dehiscence than the other osteosyntheses. Additionally, osteosynthesis deformation was found to be lower for the fixed-angle plate. A bilateral fixed-angle plate was the most rigid and stable osteosynthesis for horizontal patella fractures with the least amount of fracture gap dehiscence. Further biomechanical trials performed under cycling loading with fresh cadaver specimen should be done to figure out if a fixed-angle plate may be an alternative in the surgical treatment of patella fractures. Copyright 2009 Elsevier Ltd. All rights reserved.
Biomechanical Properties of a Novel Biodegradable Magnesium-Based Interference Screw
Ezechieli, Marco; Meyer, Hanna; Lucas, Arne; Helmecke, Patrick; Becher, Christoph; Calliess, Tilman; Windhagen, Henning; Ettinger, Max
2016-01-01
Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA) were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57). Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05). Stiffness was 121.1±13.8 N/mm for the magnesium-based screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32). MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future. PMID:27433303
Failure of engineering artifacts: a life cycle approach.
Del Frate, Luca
2013-09-01
Failure is a central notion both in ethics of engineering and in engineering practice. Engineers devote considerable resources to assure their products will not fail and considerable progress has been made in the development of tools and methods for understanding and avoiding failure. Engineering ethics, on the other hand, is concerned with the moral and social aspects related to the causes and consequences of technological failures. But what is meant by failure, and what does it mean that a failure has occurred? The subject of this paper is how engineers use and define this notion. Although a traditional definition of failure can be identified that is shared by a large part of the engineering community, the literature shows that engineers are willing to consider as failures also events and circumstance that are at odds with this traditional definition. These cases violate one or more of three assumptions made by the traditional approach to failure. An alternative approach, inspired by the notion of product life cycle, is proposed which dispenses with these assumptions. Besides being able to address the traditional cases of failure, it can deal successfully with the problematic cases. The adoption of a life cycle perspective allows the introduction of a clearer notion of failure and allows a classification of failure phenomena that takes into account the roles of stakeholders involved in the various stages of a product life cycle.
Collins, Sean P; Storrow, Alan B; Levy, Phillip D; Albert, Nancy; Butler, Javed; Ezekowitz, Justin A; Felker, G Michael; Fermann, Gregory J; Fonarow, Gregg C; Givertz, Michael M; Hiestand, Brian; Hollander, Judd E; Lanfear, David E; Pang, Peter S; Peacock, W Frank; Sawyer, Douglas B; Teerlink, John R; Lenihan, Daniel J
2015-01-01
Heart failure (HF) afflicts nearly 6 million Americans, resulting in 1 million emergency department (ED) visits and over 1 million annual hospital discharges. The majority of inpatient admissions originate in the ED; thus, it is crucial that emergency physicians and other providers involved in early management understand the latest developments in diagnostic testing, therapeutics, and alternatives to hospitalization. This article discusses contemporary ED management as well as the necessary next steps for ED-based acute HF research. © 2015 by the Society for Academic Emergency Medicine.
Time-frequency vibration analysis for the detection of motor damages caused by bearing currents
NASA Astrophysics Data System (ADS)
Prudhom, Aurelien; Antonino-Daviu, Jose; Razik, Hubert; Climente-Alarcon, Vicente
2017-02-01
Motor failure due to bearing currents is an issue that has drawn an increasing industrial interest over recent years. Bearing currents usually appear in motors operated by variable frequency drives (VFD); these drives may lead to common voltage modes which cause currents induced in the motor shaft that are discharged through the bearings. The presence of these currents may lead to the motor bearing failure only few months after system startup. Vibration monitoring is one of the most common ways for detecting bearing damages caused by circulating currents; the evaluation of the amplitudes of well-known characteristic components in the vibration Fourier spectrum that are associated with race, ball or cage defects enables to evaluate the bearing condition and, hence, to identify an eventual damage due to bearing currents. However, the inherent constraints of the Fourier transform may complicate the detection of the progressive bearing degradation; for instance, in some cases, other frequency components may mask or be confused with bearing defect-related while, in other cases, the analysis may not be suitable due to the eventual non-stationary nature of the captured vibration signals. Moreover, the fact that this analysis implies to lose the time-dimension limits the amount of information obtained from this technique. This work proposes the use of time-frequency (T-F) transforms to analyse vibration data in motors affected by bearing currents. The experimental results obtained in real machines show that the vibration analysis via T-F tools may provide significant advantages for the detection of bearing current damages; among other, these techniques enable to visualise the progressive degradation of the bearing while providing an effective discrimination versus other components that are not related with the fault. Moreover, their application is valid regardless of the operation regime of the machine. Both factors confirm the robustness and reliability of these tools that may be an interesting alternative for detecting this type of failure in induction motors.
Steinberger, Dina M; Douglas, Stephen V; Kirschbaum, Mark S
2009-09-01
A multidisciplinary team from the University of Wisconsin Hospital and Clinics transplant program used failure mode and effects analysis to proactively examine opportunities for communication and handoff failures across the continuum of care from organ procurement to transplantation. The team performed a modified failure mode and effects analysis that isolated the multiple linked, serial, and complex information exchanges occurring during the transplantation of one solid organ. Failure mode and effects analysis proved effective for engaging a diverse group of persons who had an investment in the outcome in analysis and discussion of opportunities to improve the system's resilience for avoiding errors during a time-pressured and complex process.
Failure Mode, Effects, and Criticality Analysis (FMECA)
1993-04-01
Preliminary Failure Modes, Effects and Criticality Analysis (FMECA) of the Brayton Isotope Power System Ground Demonstration System, Report No. TID 27301...No. TID/SNA - 3015, Aeroject Nuclear Systems Co., Sacramento, California: 1970. 95. Taylor , J.R. A Formalization of Failure Mode Analysis of Control...Roskilde, Denmark: 1973. 96. Taylor , J.R. A Semi-Automatic Method for Oualitative Failure Mode Analysis. Report No. RISO-M-1707. Available from a
Comprehension and retrieval of failure cases in airborne observatories
NASA Technical Reports Server (NTRS)
Alvarado, Sergio J.; Mock, Kenrick J.
1995-01-01
This paper describes research dealing with the computational problem of analyzing and repairing failures of electronic and mechanical systems of telescopes in NASA's airborne observatories, such as KAO (Kuiper Airborne Observatory) and SOFIA (Stratospheric Observatory for Infrared Astronomy). The research has resulted in the development of an experimental system that acquires knowledge of failure analysis from input text, and answers questions regarding failure detection and correction. The system's design builds upon previous work on text comprehension and question answering, including: knowledge representation for conceptual analysis of failure descriptions, strategies for mapping natural language into conceptual representations, case-based reasoning strategies for memory organization and indexing, and strategies for memory search and retrieval. These techniques have been combined into a model that accounts for: (a) how to build a knowledge base of system failures and repair procedures from descriptions that appear in telescope-operators' logbooks and FMEA (failure modes and effects analysis) manuals; and (b) how to use that knowledge base to search and retrieve answers to questions about causes and effects of failures, as well as diagnosis and repair procedures. This model has been implemented in FANSYS (Failure ANalysis SYStem), a prototype text comprehension and question answering program for failure analysis.
Comprehension and retrieval of failure cases in airborne observatories
NASA Astrophysics Data System (ADS)
Alvarado, Sergio J.; Mock, Kenrick J.
1995-05-01
This paper describes research dealing with the computational problem of analyzing and repairing failures of electronic and mechanical systems of telescopes in NASA's airborne observatories, such as KAO (Kuiper Airborne Observatory) and SOFIA (Stratospheric Observatory for Infrared Astronomy). The research has resulted in the development of an experimental system that acquires knowledge of failure analysis from input text, and answers questions regarding failure detection and correction. The system's design builds upon previous work on text comprehension and question answering, including: knowledge representation for conceptual analysis of failure descriptions, strategies for mapping natural language into conceptual representations, case-based reasoning strategies for memory organization and indexing, and strategies for memory search and retrieval. These techniques have been combined into a model that accounts for: (a) how to build a knowledge base of system failures and repair procedures from descriptions that appear in telescope-operators' logbooks and FMEA (failure modes and effects analysis) manuals; and (b) how to use that knowledge base to search and retrieve answers to questions about causes and effects of failures, as well as diagnosis and repair procedures. This model has been implemented in FANSYS (Failure ANalysis SYStem), a prototype text comprehension and question answering program for failure analysis.
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2012 CFR
2012-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2013 CFR
2013-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2014 CFR
2014-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
14 CFR 417.309 - Flight safety system analysis.
Code of Federal Regulations, 2011 CFR
2011-01-01
... system anomaly occurring and all of its effects as determined by the single failure point analysis and... termination system. (c) Single failure point. A command control system must undergo an analysis that... fault tree analysis or a failure modes effects and criticality analysis; (2) Identify all possible...
Scaling Impacts in Life Support Architecture and Technology Selection
NASA Technical Reports Server (NTRS)
Lange, Kevin
2016-01-01
For long-duration space missions outside of Earth orbit, reliability considerations will drive higher levels of redundancy and/or on-board spares for life support equipment. Component scaling will be a critical element in minimizing overall launch mass while maintaining an acceptable level of system reliability. Building on an earlier reliability study (AIAA 2012-3491), this paper considers the impact of alternative scaling approaches, including the design of technology assemblies and their individual components to maximum, nominal, survival, or other fractional requirements. The optimal level of life support system closure is evaluated for deep-space missions of varying duration using equivalent system mass (ESM) as the comparative basis. Reliability impacts are included in ESM by estimating the number of component spares required to meet a target system reliability. Common cause failures are included in the analysis. ISS and ISS-derived life support technologies are considered along with selected alternatives. This study focusses on minimizing launch mass, which may be enabling for deep-space missions.
Structural analysis of a bolted joint concept for the space shuttle's solid rocket motor casing
NASA Technical Reports Server (NTRS)
Lindell, Michael C.; Stalnaker, Winifred A.
1987-01-01
The Space Shuttle Challenger accident is thought to have been caused by the failure of one of the tang-clevis joints joining together the casing segments of the Solid Rocket Motors (SRM). Excessive displacement between the tang and clevis, possibly unseating the O-ring seals, may have initiated the resulting accident. An effort was made at NASA Langley Research Center to design an alternative concept for mating the casing segments. A bolted flange joint concept was designed and analyzed to determine if the concept would effectively maintain a seal while minimizing joint weight and controlling stress levels. It is shown that under the loading conditions analyzed the seal area of the joint remains seated. The only potential stress problem is a stress concentration in the flange at the edge of the bolt hole, which is highly localized. While heavier than the existing joint, this concept does have some advantages making the bolted joint an attractive alternative.
The history of MF59(®) adjuvant: a phoenix that arose from the ashes.
O'Hagan, Derek T; Ott, Gary S; Nest, Gary Van; Rappuoli, Rino; Giudice, Giuseppe Del
2013-01-01
The first clinical trial of an MF59(®)-adjuvanted influenza vaccine (Novartis) was conducted 20 years ago in 1992. The product that emerged (Fluad(®), Novartis) was licensed first in Italy in 1997 and is now licensed worldwide in 30 countries. US licensure is expected in the coming years. By contrast, many alternative adjuvanted vaccines have failed to progress. The key decisions that allowed MF59 to succeed in such a challenging environment are highlighted here and the lessons that were learned along the way are discussed. MF59 was connected to vaccines that did not succeed and was perceived as a 'failure' before it was a success. Importantly, it never failed for safety reasons and was always well tolerated. Even when safety issues have emerged for alternative adjuvants, careful analysis of the substantial safety database for MF59 have shown that there are no significant concerns with widespread use, even in more 'sensitive' populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonen, E.P.; Johnson, K.I.; Simonen, F.A.
The Vessel Integrity Simulation Analysis (VISA-II) code was developed to allow calculations of the failure probability of a reactor pressure vessel subject to defined pressure/temperature transients. A version of the code, revised by Pacific Northwest Laboratory for the US Nuclear Regulatory Commission, was used to evaluate the sensitivities of calculated through-wall flaw probability to material, flaw and calculational assumptions. Probabilities were more sensitive to flaw assumptions than to material or calculational assumptions. Alternative flaw assumptions changed the probabilities by one to two orders of magnitude, whereas alternative material assumptions typically changed the probabilities by a factor of two or less.more » Flaw shape, flaw through-wall position and flaw inspection were sensitivities examined. Material property sensitivities included the assumed distributions in copper content and fracture toughness. Methods of modeling flaw propagation that were evaluated included arrest/reinitiation toughness correlations, multiple toughness values along the length of a flaw, flaw jump distance for each computer simulation and added error in estimating irradiated properties caused by the trend curve correlation error.« less
Challenges on non-invasive ventilation to treat acute respiratory failure in the elderly.
Scala, Raffaele
2016-11-15
Acute respiratory failure is a frequent complication in elderly patients especially if suffering from chronic cardio-pulmonary diseases. Non-invasive mechanical ventilation constitutes a successful therapeutic tool in the elderly as, like in younger patients, it is able to prevent endotracheal intubation in a wide range of acute conditions; moreover, this ventilator technique is largely applied in the elderly in whom invasive mechanical ventilation is considered not appropriated. Furthermore, the integration of new technological devices, ethical issues and environment of treatment are still largely debated in the treatment of acute respiratory failure in the elderly.This review aims at reporting and critically analyzing the peculiarities in the management of acute respiratory failure in elderly people, the role of noninvasive mechanical ventilation, the potential advantages of applying alternative or integrated therapeutic tools (i.e. high-flow nasal cannula oxygen therapy, non-invasive and invasive cough assist devices and low-flow carbon-dioxide extracorporeal systems), drawbacks in physician's communication and "end of life" decisions. As several areas of this topic are not supported by evidence-based data, this report takes in account also "real-life" data as well as author's experience.The choice of the setting and of the timing of non-invasive mechanical ventilation in elderly people with advanced cardiopulmonary disease should be carefully evaluated together with the chance of using integrated or alternative supportive devices. Last but not least, economic and ethical issues may often challenges the behavior of the physicians towards elderly people who are hospitalized for acute respiratory failure at the end stage of their cardiopulmonary and neoplastic diseases.
Energy Alternatives. Volume 2, No. 8
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mielke, G.
1984-08-01
Some new ways of financing energy-efficient homes are briefly discussed. A vertical axis wind turbine operating at an Illinois residence is described. The failure of the 40% federal renewable energy tax credit to be extended beyond December 31, 1985, and legislation concerning the manufacture, importation, and use of alcohol fuels are reported. An alternative way of constructing exterior corners using only two studs with drywall clips is described. (LEW)
ERIC Educational Resources Information Center
General Accounting Office, Washington, DC.
More than 250,000 federal employees nationwide are participating in a three-year voluntary experiment to find out if the federal government can successfully use flexible and compressed work schedules as alternatives to the traditional eight-hour day, forty-hour workweek. If the experiment is a success, the Congress may modify laws to allow…
Failure mode analysis to predict product reliability.
NASA Technical Reports Server (NTRS)
Zemanick, P. P.
1972-01-01
The failure mode analysis (FMA) is described as a design tool to predict and improve product reliability. The objectives of the failure mode analysis are presented as they influence component design, configuration selection, the product test program, the quality assurance plan, and engineering analysis priorities. The detailed mechanics of performing a failure mode analysis are discussed, including one suggested format. Some practical difficulties of implementation are indicated, drawn from experience with preparing FMAs on the nuclear rocket engine program.
Olsen, M E; Bishara, S E; Damon, P; Jakobsen, J R
1997-05-01
Damage to the enamel surface during bonding and debonding of orthodontic brackets is a clinical concern. Alternative bonding methods that minimize enamel surface damage while maintaining a clinically useful bond strength is an aim of current research. The purpose of this study was to compare the effects on bond strength and bracket failure location of two adhesives (System 1+ and Scotchbond Multipurpose, 3M Dental Products Division) and two enamel conditioners (37% phosphoric acid and 10% maleic acid). Forty-eight freshly extracted human premolars were pumiced and divided into four groups of 12 teeth, and metal orthodontic brackets were attached to the enamel surface by one of four protocols: (1) System 1+ and phosphoric acid, (2) Scotchbond and phosphoric acid, (3) System 1+ and maleic acid, and (4) Scotchbond and maleic acid. After bracket attachment, the teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 72 hours. A Zwick universal testing machine (Zwick GmbH & Co.) was used to determine shear bond strengths. The residual adhesive on the enamel surface was evaluated with the Adhesive Remnant Index. The analysis of variance was used to compare the four groups. Significance was predetermined at p < or = 0.05. The results indicated that there were no significant differences in bond strength among the four groups (p = 0.386). The results of the Chi square test, evaluating the residual adhesives on the enamel surfaces, revealed significant differences among the four groups (mean 2 = 0.005). A Duncan multiple range test revealed the difference occurred between the phosphoric acid and maleic acid groups, with maleic acid having bond failures at the enamel-adhesive interface. In conclusion, the use of Scotchbond Multipurpose and/or maleic acid does not significantly effect bond strength, however, the use of maleic acid resulted in an unfavorable bond failure location.
Bosserman, Elizabeth A; Helms, Donna J; Mosure, Debra J; Secor, W Evan; Workowski, Kimberly A
2011-10-01
Antimicrobial resistance is one of the causes of treatment failure in women after standard nitroimidazole therapy for Trichomonas vaginalis infections. The Centers for Disease Control and Prevention provides drug susceptibility testing and guidance for treatment failures but the efficacy of the alternate recommendations has not been assessed. T. vaginalis isolates from women who had failed at least 2 courses of standard therapy for trichomoniasis were submitted to the Centers for Disease Control and Prevention for susceptibility testing. Alternative treatment recommendations were provided based on in vitro drug susceptibility results and clinical outcomes were collected. Drug susceptibility results were available for 175 women tested between January 2002 and January 2008. In vitro, 115 of the 175 isolates demonstrated metronidazole resistance. For all isolates resistant to metronidazole, in vitro resistance to tinidazole was similar or lower. Clinical treatment outcomes were available for 72 women. Of the women receiving an alternative recommended nitroimidazole regimen, 30 (83%) of 36 were cured compared with 8 (57%) of 14 women who received a lower dose than recommended. Clinical and microbiologic success was attained in 59 (82%) of 72 women whose follow-up information was available, with some women requiring multiple treatment courses. Clinical and microbiologic cure rates were higher for women who were treated in accordance with the recommendation provided after in vitro testing compared with those who received a lower dose or a different drug. Susceptibility testing leading to tailored treatment may have a beneficial role for management of women with persistent trichomoniasis.
Fernandes, Juliana Folloni; Bonfim, Carmem; Kerbauy, Fábio Rodrigues; Rodrigues, Morgani; Esteves, Iracema; Silva, Nathalia Halley; Azambuja, Alessandra Prandini; Mantovani, Luiz Fernando; Kutner, José Mauro; Loth, Gisele; Kuwahara, Cilmara Cristina; Bueno, Clarissa; Kondo, Andrea Tiemi; Ribeiro, Andreza Alice Feitosa; Kok, Fernando; Hamerschlak, Nelson
2018-04-01
Allogeneic hematopoietic stem cell transplantation (HSCT) is the only treatment that enhances survival and stabilizes neurologic symptoms in X-linked adrenoleukodystrophy (X-ALD) with cerebral involvement, a severe demyelinating disease of childhood. Patients with X-ALD who lack a well-matched HLA donor need a rapid alternative. Haploidentical HSCT using post transplant cyclophosphamide (PT/Cy) has been performed in patients with malignant and nonmalignant diseases showing similar outcomes compared to other alternative sources. We describe the outcomes of transplants performed for nine X-ALD patients using haploidentical donors and PT/Cy. Patients received conditioning regimen with fludarabine 150 mg/m 2 , cyclophosphamide 29 mg/kg and 2 Gy total body irradiation (TBI) with or without antithymocyte globulin. Graft-vs.-host disease prophylaxis consisted of cyclophosphamide 50 mg/kg/day on days +3 and +4, tacrolimus or cyclosporine A and mycophenolate mofetil. One patient had a primary graft failure and was not eligible for a second transplant. Three patients had secondary graft failure and were successfully rescued with second haploidentical transplants. Trying to improve engraftment, conditioning regimen was changed, substituting 2 Gy TBI for 4 Gy total lymphoid irradiation. Eight patients are alive and engrafted (17-37 months after transplant). Haploidentical HSCT with PT/Cy is a feasible alternative for X-ALD patients lacking a suitable matched donor. Graft failure has to be addressed in further studies.
Failure Analysis at the Kennedy Space Center
NASA Technical Reports Server (NTRS)
Salazar, Victoria L.; Wright, M. Clara
2010-01-01
History has shown that failures occur in every engineering endeavor, and what we learn from those failures contributes to the knowledge base to safely complete future missions. The necessity of failure analysis is at its apex at the end of one aged program and at the beginning of a new and untested program. The information that we gain through failure analysis corrects the deficiencies in the current vehicle to make the next generation of vehicles more efficient and safe. The Failure Analysis and Materials Evaluation Branch in the Materials Science Division at the Kennedy Space Center performs metallurgical, mechanical, electrical, and non-metallic materials failure analyses and accident investigations on both flight hardware and ground support equipment for the Space Shuttle, International Space Station, Constellation, and Launch Services Programs. This paper will explore a variety of failure case studies at the Kennedy Space Center and the lessons learned that can be applied in future programs.
NASA Astrophysics Data System (ADS)
Son, Ho-Young; Kim, Ilho; Lee, Soon-Bok; Jung, Gi-Jo; Park, Byung-Jin; Paik, Kyung-Wook
2009-01-01
A thick Cu column based double-bump flip chip structure is one of the promising alternatives for fine pitch flip chip applications. In this study, the thermal cycling (T/C) reliability of Cu/SnAg double-bump flip chip assemblies was investigated, and the failure mechanism was analyzed through the correlation of T/C test and the finite element analysis (FEA) results. After 1000 thermal cycles, T/C failures occurred at some Cu/SnAg bumps located at the edge and corner of chips. Scanning acoustic microscope analysis and scanning electron microscope observations indicated that the failure site was the Cu column/Si chip interface. It was identified by a FEA where the maximum stress concentration was located during T/C. During T/C, the Al pad between the Si chip and a Cu column bump was displaced due to thermomechanical stress. Based on the low cycle fatigue model, the accumulation of equivalent plastic strain resulted in thermal fatigue deformation of the Cu column bumps and ultimately reduced the thermal cycling lifetime. The maximum equivalent plastic strains of some bumps at the chip edge increased with an increased number of thermal cycles. However, equivalent plastic strains of the inner bumps did not increase regardless of the number of thermal cycles. In addition, the z-directional normal plastic strain ɛ22 was determined to be compressive and was a dominant component causing the plastic deformation of Cu/SnAg double bumps. As the number of thermal cycles increased, normal plastic strains in the perpendicular direction to the Si chip and shear strains were accumulated on the Cu column bumps at the chip edge at low temperature region. Thus it was found that the Al pad at the Si chip/Cu column interface underwent thermal fatigue deformation by compressive normal strain and the contact loss by displacement failure of the Al pad, the main T/C failure mode of the Cu/SnAg flip chip assembly, then occurred at the Si chip/Cu column interface shear strain deformation during T/C.
Failure Mode Identification Through Clustering Analysis
NASA Technical Reports Server (NTRS)
Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)
2002-01-01
Research has shown that nearly 80% of the costs and problems are created in product development and that cost and quality are essentially designed into products in the conceptual stage. Currently, failure identification procedures (such as FMEA (Failure Modes and Effects Analysis), FMECA (Failure Modes, Effects and Criticality Analysis) and FTA (Fault Tree Analysis)) and design of experiments are being used for quality control and for the detection of potential failure modes during the detail design stage or post-product launch. Though all of these methods have their own advantages, they do not give information as to what are the predominant failures that a designer should focus on while designing a product. This work uses a functional approach to identify failure modes, which hypothesizes that similarities exist between different failure modes based on the functionality of the product/component. In this paper, a statistical clustering procedure is proposed to retrieve information on the set of predominant failures that a function experiences. The various stages of the methodology are illustrated using a hypothetical design example.
NASA Astrophysics Data System (ADS)
Pierson, Kyle D.; Hochhalter, Jacob D.; Spear, Ashley D.
2018-05-01
Systematic correlation analysis was performed between simulated micromechanical fields in an uncracked polycrystal and the known path of an eventual fatigue-crack surface based on experimental observation. Concurrent multiscale finite-element simulation of cyclic loading was performed using a high-fidelity representation of grain structure obtained from near-field high-energy x-ray diffraction microscopy measurements. An algorithm was developed to parameterize and systematically correlate the three-dimensional (3D) micromechanical fields from simulation with the 3D fatigue-failure surface from experiment. For comparison, correlation coefficients were also computed between the micromechanical fields and hypothetical, alternative surfaces. The correlation of the fields with hypothetical surfaces was found to be consistently weaker than that with the known crack surface, suggesting that the micromechanical fields of the cyclically loaded, uncracked microstructure might provide some degree of predictiveness for microstructurally small fatigue-crack paths, although the extent of such predictiveness remains to be tested. In general, gradients of the field variables exhibit stronger correlations with crack path than the field variables themselves. Results from the data-driven approach implemented here can be leveraged in future model development for prediction of fatigue-failure surfaces (for example, to facilitate univariate feature selection required by convolution-based models).
Graphical Displays Assist In Analysis Of Failures
NASA Technical Reports Server (NTRS)
Pack, Ginger; Wadsworth, David; Razavipour, Reza
1995-01-01
Failure Environment Analysis Tool (FEAT) computer program enables people to see and better understand effects of failures in system. Uses digraph models to determine what will happen to system if set of failure events occurs and to identify possible causes of selected set of failures. Digraphs or engineering schematics used. Also used in operations to help identify causes of failures after they occur. Written in C language.
Shivakoti, Rupak; Yang, Wei-Teng; Gupte, Nikhil; Berendes, Sima; Rosa, Alberto La; Cardoso, Sandra W.; Mwelase, Noluthando; Kanyama, Cecilia; Pillay, Sandy; Samaneka, Wadzanai; Riviere, Cynthia; Sugandhavesa, Patcharaphan; Santos, Brento; Poongulali, Selvamuthu; Tripathy, Srikanth; Bollinger, Robert C.; Currier, Judith S.; Tang, Alice M.; Semba, Richard D.; Christian, Parul; Campbell, Thomas B.; Gupta, Amita
2015-01-01
Background. Anemia is a known risk factor for clinical failure following antiretroviral therapy (ART). Notably, anemia and inflammation are interrelated, and recent studies have associated elevated C-reactive protein (CRP), an inflammation marker, with adverse human immunodeficiency virus (HIV) treatment outcomes, yet their joint effect is not known. The objective of this study was to assess prevalence and risk factors of anemia in HIV infection and to determine whether anemia and elevated CRP jointly predict clinical failure post-ART. Methods. A case-cohort study (N = 470 [236 cases, 234 controls]) was nested within a multinational randomized trial of ART efficacy (Prospective Evaluation of Antiretrovirals in Resource Limited Settings [PEARLS]). Cases were incident World Health Organization stage 3, 4, or death by 96 weeks of ART treatment (clinical failure). Multivariable logistic regression was used to determine risk factors for pre-ART (baseline) anemia (females: hemoglobin <12.0 g/dL; males: hemoglobin <13.0 g/dL). Association of anemia as well as concurrent baseline anemia and inflammation (CRP ≥10 mg/L) with clinical failure were assessed using multivariable Cox models. Results. Baseline anemia prevalence was 51% with 15% prevalence of concurrent anemia and inflammation. In analysis of clinical failure, multivariate-adjusted hazard ratios were 6.41 (95% confidence interval [CI], 2.82–14.57) for concurrent anemia and inflammation, 0.77 (95% CI, .37–1.58) for anemia without inflammation, and 0.45 (95% CI, .11–1.80) for inflammation without anemia compared to those without anemia and inflammation. Conclusions. ART-naive, HIV-infected individuals with concurrent anemia and inflammation are at particularly high risk of failing treatment, and understanding the pathogenesis could lead to new interventions. Reducing inflammation and anemia will likely improve HIV disease outcomes. Alternatively, concurrent anemia and inflammation could represent individuals with occult opportunistic infections in need of additional screening. PMID:25828994
Abdelhamid, Mahmoud; Mosharafa, Ashraf A; Ibrahim, Hamdy; Selim, Hany M; Hamed, Mohamed; Elghoneimy, Mohamed N; Salem, Hosny K; Abdelazim, Mohamed S; Badawy, Hesham
2016-11-01
To evaluate the ability of noncontrast CT parameters (stone size, stone attenuation, and skin-to-stone distance [SSD]) to predict the outcome of extracorporeal shockwave lithotripsy (SWL) in a prospective cohort of patients with renal and upper ureteric stones. Patients with stones 5 to 20 mm were prospectively enrolled from 2011 to 2014. Patients had NCCT with recording of stone size, stone mean attenuation, and SSD, as well as various stone and patient parameters. The numbers of needed sessions as well as the final outcome were determined, with SWL failure defined as residual fragments >3 mm. Predictors of SWL failure were assessed by multiple regression analysis. Two hundred twenty patients (mean ± standard deviation [SD] age 41.5 ± 12.4 years) underwent SWL. Mean ± SD stone size was 11.3 ± 4.1 mm, while mean ± SD stone attenuation was 795.1 ± 340.4 HU. Mean ± SD SSD was 9.4 ± 2.1 cm. The average number of sessions was 1.64. SWL was effective in 186 (84.5%) patients (group A), while 34 (15.5%) patients had significant residual fragments (>3 mm). On univariate analysis, predictors of SWL failure included stone attenuation >1000 HU, older age, higher body mass index, higher attenuation value, larger stone size, and longer SSD. Increased SSD and higher stone attenuation retained their significance as independent predictors of SWL failure (p < 0.05) on multiple regression analysis both after first session and as final SWL outcome. A positive correlation was found between number of SWL sessions and mean stone attenuation (r = 0.6, p < 0.001) and SSD (r = 4, p < 0.001). Stone mean attenuation and SSD on noncontrast CT are significant independent predictors of SWL outcome in patients with renal and ureteric stones. These parameters should be included in clinical decision algorithms for patients with urolithiasis. For patients with stones having mean attenuation of >1000 HU and/or large SSDs, alternatives to SWL should be considered.
NASA Technical Reports Server (NTRS)
Arakere, N. K.; Swanson, G.
2002-01-01
High cycle fatigue (HCF) induced failures in aircraft gas turbine and rocket engine turbopump blades is a pervasive problem. Single crystal nickel turbine blades are being utilized in rocket engine turbopumps and jet engines throughout industry because of their superior creep, stress rupture, melt resistance, and thermomechanical fatigue capabilities over polycrystalline alloys. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493, PWA 1484, RENE' N-5 and CMSX-4. These alloys play an important role in commercial, military and space propulsion systems. Single crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant factor in the overall analysis. The failure modes of single crystal turbine blades are complicated to predict due to the material orthotropy and variations in crystal orientations. Fatigue life estimation of single crystal turbine blades represents an important aspect of durability assessment. It is therefore of practical interest to develop effective fatigue failure criteria for single crystal nickel alloys and to investigate the effects of variation of primary and secondary crystal orientation on fatigue life. A fatigue failure criterion based on the maximum shear stress amplitude /Delta(sub tau)(sub max))] on the 24 octahedral and 6 cube slip systems, is presented for single crystal nickel superalloys (FCC crystal). This criterion reduces the scatter in uniaxial LCF test data considerably for PWA 1493 at 1200 F in air. Additionally, single crystal turbine blades used in the alternate advanced high-pressure fuel turbopump (AHPFTP/AT) are modeled using a large-scale three-dimensional finite element model. This finite element model is capable of accounting for material orthotrophy and variation in primary and secondary crystal orientation. Effects of variation in crystal orientation on blade stress response are studied based on 297 finite element model runs. Fatigue lives at critical points in the blade are computed using finite element stress results and the failure criterion developed. Stress analysis results in the blade attachment region are also presented. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to significantly increase a component S resistance to fatigue crack growth with- out adding additional weight or cost. [DOI: 10.1115/1.1413767
A Framework for Creating a Function-based Design Tool for Failure Mode Identification
NASA Technical Reports Server (NTRS)
Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)
2002-01-01
Knowledge of potential failure modes during design is critical for prevention of failures. Currently industries use procedures such as Failure Modes and Effects Analysis (FMEA), Fault Tree analysis, or Failure Modes, Effects and Criticality analysis (FMECA), as well as knowledge and experience, to determine potential failure modes. When new products are being developed there is often a lack of sufficient knowledge of potential failure mode and/or a lack of sufficient experience to identify all failure modes. This gives rise to a situation in which engineers are unable to extract maximum benefits from the above procedures. This work describes a function-based failure identification methodology, which would act as a storehouse of information and experience, providing useful information about the potential failure modes for the design under consideration, as well as enhancing the usefulness of procedures like FMEA. As an example, the method is applied to fifteen products and the benefits are illustrated.
Diagnostics of wear in aeronautical systems
NASA Technical Reports Server (NTRS)
Wedeven, L. D.
1979-01-01
The use of appropriate diagnostic tools for aircraft oil wetted components is reviewed, noting that it can reduce direct operating costs through reduced unscheduled maintenance, particularly in helicopter engine and transmission systems where bearing failures are a significant cost factor. Engine and transmission wear modes are described, and diagnostic methods for oil and wet particle analysis, the spectrometric oil analysis program, chip detectors, ferrography, in-line oil monitor and radioactive isotope tagging are discussed, noting that they are effective over a limited range of particle sizes but compliment each other if used in parallel. Fine filtration can potentially increase time between overhauls, but reduces the effectiveness of conventional oil monitoring techniques so that alternative diagnostic techniques must be used. It is concluded that the development of a diagnostic system should be parallel and integral with the development of a mechanical system.
Alternative Level of Care: Canada's Hospital Beds, the Evidence and Options
Sutherland, Jason M.; Crump, R. Trafford
2013-01-01
Patients designated as alternative level of care (ALC) are an ongoing concern for healthcare policy makers across Canada. These patients occupy valuable hospital beds and limit access to acute care services. The objective of this paper is to present policy alternatives to address underlying factors associated with ALC bed use. Three alternatives, and their respective limitations and structural challenges, are discussed. Potential solutions may require a mix of policy options proposed here. Inadequate policy jeopardizes new acute care activity-based funding schemes in British Columbia and Ontario. Failure to address this issue could exacerbate pressures on the existing bottlenecks in the community care system in these and other provinces. PMID:23968671
Failure-Modes-And-Effects Analysis Of Software Logic
NASA Technical Reports Server (NTRS)
Garcia, Danny; Hartline, Thomas; Minor, Terry; Statum, David; Vice, David
1996-01-01
Rigorous analysis applied early in design effort. Method of identifying potential inadequacies and modes and effects of failures caused by inadequacies (failure-modes-and-effects analysis or "FMEA" for short) devised for application to software logic.
Failure Mode and Effects Analysis (FMEA) Introductory Overview
2012-06-14
Failure Mode and Effects Analysis ( FMEA ) Introductory Overview TARDEC Systems Engineering Risk Management Team POC: Kadry Rizk or Gregor Ratajczak...2. REPORT TYPE Briefing Charts 3. DATES COVERED 01-05-2012 to 23-05-2012 4. TITLE AND SUBTITLE Failure Mode and Effects Analysis ( FMEA ) 5a...18 WELCOME Welcome to “An introductory overview of Failure Mode and Effects Analysis ( FMEA )”, A brief concerning the use and benefits of FMEA
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes, These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
Alternative aggregates and materials for high friction surface treatments : [summary].
DOT National Transportation Integrated Search
2016-07-01
Researchers at the Texas A&M Transportation Institute studied the materials and practices that best eliminate premature HFST failures and reduce overall HFST costs, while maintaining or improving treatment life and friction performance.
Emergent Irreversibility and Entanglement Spectrum Statistics
NASA Astrophysics Data System (ADS)
Chamon, Claudio; Hamma, Alioscia; Mucciolo, Eduardo R.
2014-06-01
We study the problem of irreversibility when the dynamical evolution of a many-body system is described by a stochastic quantum circuit. Such evolution is more general than a Hamiltonian one, and since energy levels are not well defined, the well-established connection between the statistical fluctuations of the energy spectrum and irreversibility cannot be made. We show that the entanglement spectrum provides a more general connection. Irreversibility is marked by a failure of a disentangling algorithm and is preceded by the appearance of Wigner-Dyson statistical fluctuations in the entanglement spectrum. This analysis can be done at the wave-function level and offers an alternative route to study quantum chaos and quantum integrability.
Lindley frailty model for a class of compound Poisson processes
NASA Astrophysics Data System (ADS)
Kadilar, Gamze Özel; Ata, Nihal
2013-10-01
The Lindley distribution gain importance in survival analysis for the similarity of exponential distribution and allowance for the different shapes of hazard function. Frailty models provide an alternative to proportional hazards model where misspecified or omitted covariates are described by an unobservable random variable. Despite of the distribution of the frailty is generally assumed to be continuous, it is appropriate to consider discrete frailty distributions In some circumstances. In this paper, frailty models with discrete compound Poisson process for the Lindley distributed failure time are introduced. Survival functions are derived and maximum likelihood estimation procedures for the parameters are studied. Then, the fit of the models to the earthquake data set of Turkey are examined.
NASA Astrophysics Data System (ADS)
Gan, Luping; Li, Yan-Feng; Zhu, Shun-Peng; Yang, Yuan-Jian; Huang, Hong-Zhong
2014-06-01
Failure mode, effects and criticality analysis (FMECA) and Fault tree analysis (FTA) are powerful tools to evaluate reliability of systems. Although single failure mode issue can be efficiently addressed by traditional FMECA, multiple failure modes and component correlations in complex systems cannot be effectively evaluated. In addition, correlated variables and parameters are often assumed to be precisely known in quantitative analysis. In fact, due to the lack of information, epistemic uncertainty commonly exists in engineering design. To solve these problems, the advantages of FMECA, FTA, fuzzy theory, and Copula theory are integrated into a unified hybrid method called fuzzy probability weighted geometric mean (FPWGM) risk priority number (RPN) method. The epistemic uncertainty of risk variables and parameters are characterized by fuzzy number to obtain fuzzy weighted geometric mean (FWGM) RPN for single failure mode. Multiple failure modes are connected using minimum cut sets (MCS), and Boolean logic is used to combine fuzzy risk priority number (FRPN) of each MCS. Moreover, Copula theory is applied to analyze the correlation of multiple failure modes in order to derive the failure probabilities of each MCS. Compared to the case where dependency among multiple failure modes is not considered, the Copula modeling approach eliminates the error of reliability analysis. Furthermore, for purpose of quantitative analysis, probabilities importance weight from failure probabilities are assigned to FWGM RPN to reassess the risk priority, which generalize the definition of probability weight and FRPN, resulting in a more accurate estimation than that of the traditional models. Finally, a basic fatigue analysis case drawn from turbine and compressor blades in aeroengine is used to demonstrate the effectiveness and robustness of the presented method. The result provides some important insights on fatigue reliability analysis and risk priority assessment of structural system under failure correlations.
Moore, Paul A; Cuddy, Michael A; Cooke, Matthew R; Sokolowski, Chester J
2011-09-01
and Overview. The provision of mandibular anesthesia traditionally has relied on nerve block anesthetic techniques such as the Halsted, the Gow-Gates and the Akinosi-Vazirani methods. The authors present two alternative techniques to provide local anesthesia in mandibular teeth: the periodontal ligament (PDL) injection and the intraosseous (IO) injection. The authors also present indications for and complications associated with these techniques. The PDL injection and the IO injection are effective anesthetic techniques for managing nerve block failures and for providing localized anesthesia in the mandible. Dentists may find these techniques to be useful alternatives to nerve block anesthesia.
NASA Technical Reports Server (NTRS)
Stahle, C. V.; Gongloff, H. R.
1977-01-01
A preliminary assessment of vibroacoustic test plan optimization for free flyer STS payloads is presented and the effects on alternate test plans for Spacelab sortie payloads number of missions are also examined. The component vibration failure probability and the number of components in the housekeeping subassemblies are provided. Decision models are used to evaluate the cost effectiveness of seven alternate test plans using protoflight hardware.
Economic Leverage on the Soviet Union in the 1980s.
1984-07-01
structure of the external markets and the Soviet will to resist the foreign pressure and assume the attendant costs. Consideration of the elements making up...additional handi- caps of late development of alternative energy plans, failure to offer alternative markets for the sales of pipe and equipment, and...be left to the dic- tates of the market , but in actuality every government intervenes to shape market flows to some extent. Where purposeful
ERIC Educational Resources Information Center
Ahn, Sunyoung; Simpson, Richard
2013-01-01
The purpose of this study was to investigate the relationships between the perceptions of school membership, risk factors, and behavioral and academic engagement among a sample of alternative school students. The study subjects were 48 7th-9th graders who were at high risk for school failure because of their serious and chronic behavioral and…
Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P
2016-07-01
Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.
Peridynamic theory for modeling three-dimensional damage growth in metallic and composite structures
NASA Astrophysics Data System (ADS)
Ochoa-Ricoux, Juan Pedro
A recently introduced nonlocal peridynamic theory removes the obstacles present in classical continuum mechanics that limit the prediction of crack initiation and growth in materials. It is also applicable at different length scales. This study presents an alternative approach for the derivation of peridynamic equations of motion based on the principle of virtual work. It also presents solutions for the longitudinal vibration of a bar subjected to an initial stretch, propagation of a pre-existing crack in a plate subjected to velocity boundary conditions, and crack initiation and growth in a plate with a circular cutout. Furthermore, damage growth in composites involves complex and progressive failure modes. Current computational tools are incapable of predicting failure in composite materials mainly due to their mathematical structure. However, the peridynamic theory removes these obstacles by taking into account non-local interactions between material points. Hence, an application of the peridynamic theory to predict how damage propagates in fiber reinforced composite materials subjected to mechanical and thermal loading conditions is presented. Finally, an analysis approach based on a merger of the finite element method and the peridynamic theory is proposed. Its validity is established through qualitative and quantitative comparisons against the test results for a stiffened composite curved panel with a central slot under combined internal pressure and axial tension. The predicted initial and final failure loads, as well as the final failure modes, are in close agreement with the experimental observations. This proposed approach demonstrates the capability of the PD approach to assess the durability of complex composite structures.
NASA Technical Reports Server (NTRS)
Arakere, Nagaraj K.; Swanson, Gregory R.
2000-01-01
High Cycle Fatigue (HCF) induced failures in aircraft gas-turbine engines is a pervasive problem affecting a wide range of components and materials. HCF is currently the primary cause of component failures in gas turbine aircraft engines. Turbine blades in high performance aircraft and rocket engines are increasingly being made of single crystal nickel superalloys. Single-crystal Nickel-base superalloys were developed to provide superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys previously used in the production of turbine blades and vanes. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. PWA1493, identical to PWA1480, but with tighter chemical constituent control, is used in the NASA SSME (Space Shuttle Main Engine) alternate turbopump, a liquid hydrogen fueled rocket engine. Objectives for this paper are motivated by the need for developing failure criteria and fatigue life evaluation procedures for high temperature single crystal components, using available fatigue data and finite element modeling of turbine blades. Using the FE (finite element) stress analysis results and the fatigue life relations developed, the effect of variation of primary and secondary crystal orientations on life is determined, at critical blade locations. The most advantageous crystal orientation for a given blade design is determined. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to optimize blade design by increasing its resistance to fatigue crack growth without adding additional weight or cost.
Imaging in Central Nervous System Drug Discovery.
Gunn, Roger N; Rabiner, Eugenii A
2017-01-01
The discovery and development of central nervous system (CNS) drugs is an extremely challenging process requiring large resources, timelines, and associated costs. The high risk of failure leads to high levels of risk. Over the past couple of decades PET imaging has become a central component of the CNS drug-development process, enabling decision-making in phase I studies, where early discharge of risk provides increased confidence to progress a candidate to more costly later phase testing at the right dose level or alternatively to kill a compound through failure to meet key criteria. The so called "3 pillars" of drug survival, namely; tissue exposure, target engagement, and pharmacologic activity, are particularly well suited for evaluation by PET imaging. This review introduces the process of CNS drug development before considering how PET imaging of the "3 pillars" has advanced to provide valuable tools for decision-making on the critical path of CNS drug development. Finally, we review the advances in PET science of biomarker development and analysis that enable sophisticated drug-development studies in man. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsanakas, John A.; Jaffre, Damien; Sicre, Mathieu; Elouamari, Rachid; Vossier, Alexis; de Salins, Jean-Edouard; Bechou, Laurent; Levrier, Bruno; Perona, Arnaud; Dollet, Alain
2014-09-01
This paper presents a preliminary study upon a novel approach proposed for highly accelerated ageing and reliability optimization of high concentrating photovoltaic (HCPV) cells and assemblies. The intended approach aims to overcome several limitations of some current accelerated ageing tests (AAT) adopted up today, proposing the use of an alternative experimental set-up for performing faster and more realistic thermal cycles, under real sun, without the involvement of environmental chamber. The study also includes specific characterization techniques, before and after each AAT sequence, which respectively provide the initial and final diagnosis on the condition of the tested sample. The acquired data from these diagnostic/characterization methods are then used as indices to determine both quantitatively and qualitatively the severity of degradation and, thus, the ageing level for each tested HCPV assembly or cell sample. Ultimate goal of such "initial diagnosis - AAT - final diagnosis" sequences is to provide the basis for a future work on the reliability analysis of the main degradation mechanisms and confident prediction of failure propagation in HCPV cells, by means of acceleration factor (AF) and mean-time-to-failure (MTTF) estimations.
Progressive Failure Analysis of Composite Stiffened Panels
NASA Technical Reports Server (NTRS)
Bednarcyk, Brett A.; Yarrington, Phillip W.; Collier, Craig S.; Arnold, Steven M.
2006-01-01
A new progressive failure analysis capability for stiffened composite panels has been developed based on the combination of the HyperSizer stiffened panel design/analysis/optimization software with the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC). MAC/GMC discretizes a composite material s microstructure into a number of subvolumes and solves for the stress and strain state in each while providing the homogenized composite properties as well. As a result, local failure criteria may be employed to predict local subvolume failure and the effects of these local failures on the overall composite response. When combined with HyperSizer, MAC/GMC is employed to represent the ply level composite material response within the laminates that constitute a stiffened panel. The effects of local subvolume failures can then be tracked as loading on the stiffened panel progresses. Sample progressive failure results are presented at both the composite laminate and the composite stiffened panel levels. Deformation and failure model predictions are compared with experimental data from the World Wide Failure Exercise for AS4/3501-6 graphite/epoxy laminates.
NASA Astrophysics Data System (ADS)
Bulleri, Fabio; Cucco, Andrea; Dal Bello, Martina; Maggi, Elena; Ravaglioli, Chiara; Benedetti-Cecchi, Lisandro
2018-02-01
The global decline of canopy-forming macroalgae has stimulated research on the mechanism regulating shifts among alternative habitats on rocky reefs. The effects of sea urchin grazing and alterations of environmental conditions are now acknowledged as the main drivers of shifts between canopy-formers and encrusting coralline barrens and algal turfs, respectively. The conditions under which these mechanisms operate remains, however, somewhat elusive. This is mostly a consequence of the fact that our current understanding has been generated by envisioning habitat shifts as dichotomic, at odds with rocky reef landscapes being composed by mosaics of habitats and with evidence of strong interactions among the species that compose each of the alternative habitats. Using data from a long-term sampling program and path analysis, we investigated how wave-exposure and human-induced degradation of environmental conditions regulate the mechanisms maintaining algal canopies formed by Cystoseira crinita, barren habitats and algal turfs as alternative states on subtidal reefs in the NW Mediterranean. In the Tuscan Archipelago, wave-exposure had positive effects on sea urchins, which, likely due to their low mean density, had weak effects on each of the alternative habitats. Canopy-forming macroalgae resulted, instead, to exert strong negative effects on the abundance of algal turfs. Since data from the Tuscan Archipelago did not explain any of the variation in the abundance of C. crinita canopies, a further analysis was performed including data from the coast of Tuscany to assess the role of cumulative human impacts in regulating habitat shifts. This showed that degradation of environmental conditions is a direct cause of the decline of macroalgal canopies, indirectly favouring the dominance of algal turfs. Our study suggests that management of human impacts should be considered a priority for preserving subtidal canopies formed by Cystoseira in the NW Mediterranean and that conservation efforts based exclusively on the control of sea urchin populations might be doomed to failure in some areas.
Risk Based Reliability Centered Maintenance of DOD Fire Protection Systems
1999-01-01
2.2.3 Failure Mode and Effect Analysis ( FMEA )............................ 2.2.4 Failure Mode Risk Characterization...Step 2 - System functions and functional failures definition Step 3 - Failure mode and effect analysis ( FMEA ) Step 4 - Failure mode risk...system). The Interface Location column identifies the location where the FMEA of the fire protection system began or stopped. For example, for the fire
Management of failure after surgery for gastro-esophageal reflux disease.
Gronnier, C; Degrandi, O; Collet, D
2018-04-01
Surgical treatment of gastro-esophageal reflux disease (ST-GERD) is well-codified and offers an alternative to long-term medical treatment with a better efficacy for short and long-term outcomes. However, failure of ST-GERD is observed in 2-20% of patients; management is challenging and not standardized. The aim of this study is to analyze the causes of failure and to provide a treatment algorithm. The clinical aspects of ST-GERD failure are variable including persistent reflux, dysphagia or permanent discomfort leading to an important degradation of the quality of life. A morphological and functional pre-therapeutic evaluation is necessary to: (i) determine whether the symptoms are due to recurrence of reflux or to an error in initial indication and (ii) to understand the cause of the failure. The most frequent causes of failure of ST-GERD include errors in the initial indication, which often only need medical treatment, and surgical technical errors, for which surgical redo surgery can be difficult. Multidisciplinary management is necessary in order to offer the best-adapted treatment. Copyright © 2018. Published by Elsevier Masson SAS.
Robotic Mars Sample Return: Risk Assessment and Analysis Report
NASA Technical Reports Server (NTRS)
Lalk, Thomas R.; Spence, Cliff A.
2003-01-01
A comparison of the risk associated with two alternative scenarios for a robotic Mars sample return mission was conducted. Two alternative mission scenarios were identified, the Jet Propulsion Lab (JPL) reference Mission and a mission proposed by Johnson Space Center (JSC). The JPL mission was characterized by two landers and an orbiter, and a Mars orbit rendezvous to retrieve the samples. The JSC mission (Direct/SEP) involves a solar electric propulsion (SEP) return to earth followed by a rendezvous with the space shuttle in earth orbit. A qualitative risk assessment to identify and characterize the risks, and a risk analysis to quantify the risks were conducted on these missions. Technical descriptions of the competing scenarios were developed in conjunction with NASA engineers and the sequence of events for each candidate mission was developed. Risk distributions associated with individual and combinations of events were consolidated using event tree analysis in conjunction with Monte Carlo techniques to develop probabilities of mission success for each of the various alternatives. The results were the probability of success of various end states for each candidate scenario. These end states ranged from complete success through various levels of partial success to complete failure. Overall probability of success for the Direct/SEP mission was determined to be 66% for the return of at least one sample and 58% for the JPL mission for the return of at least one sample cache. Values were also determined for intermediate events and end states as well as for the probability of violation of planetary protection. Overall mission planetary protection event probabilities of occurrence were determined to be 0.002% and 1.3% for the Direct/SEP and JPL Reference missions respectively.
Space Shuttle Stiffener Ring Foam Failure Analysis, a Non-Conventional Approach
NASA Technical Reports Server (NTRS)
Howard, Philip M.
2015-01-01
The Space Shuttle Program made use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications de-bond, classical methods of failure analysis did not provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.
Hepatic stem/progenitor cells and stem-cell transplantation for the treatment of liver disease.
Kakinuma, Sei; Nakauchi, Hiromitsu; Watanabe, Mamoru
2009-01-01
Allogeneic liver transplantation is still the only effective treatment available to patients with liver failure. However, because there is a serious shortage of liver donors, an alternative therapeutic approach is needed. Transplantation of mature hepatocytes has been evaluated in clinical trials, but the long-term efficacy remains unclear and the paucity of donor cells limits this strategy. Stem-cell transplantation is a more promising alternative approach. Several studies have provided information about the mechanism underlying the proliferation and differentiation of hepatic stem/progenitor cells. Moreover, in experimental models of liver disease, transplantation of hepatic stem/progenitor cells or hepatocyte-like cells derived from multipotent stem cells led to donor cell-mediated repopulation of the liver and improved survival rates. However, before stem-cell transplantation can be applied in the clinic to treat liver failure in humans, it will be necessary to overcome several difficulties associated with the technique.
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Kichak, Robert A.; McManamen, John P.; Kramer-White, Julie; Raju, Ivatury S.; Beil, Robert J.; Weeks, John F.; Elliott, Kenny B.
2009-01-01
The NASA Engineering and Safety Center (NESC) was tasked with assessing the validity of an alternate opinion that surfaced during the investigation of recurrent failures at the Space Shuttle T-0 umbilical interface. The most visible problem occurred during the Space Transportation System (STS)-112 launch when pyrotechnics used to separate Solid Rocket Booster (SRB) Hold-Down Post (HDP) frangible nuts failed to fire. Subsequent investigations recommended several improvements to the Ground Support Equipment (GSE) and processing changes were implemented, including replacement of ground-half cables and connectors between flights, along with wiring modifications to make critical circuits quad-redundant across the interface. The alternate opinions maintained that insufficient data existed to exonerate the design, that additional data needed to be gathered under launch conditions, and that the interface should be further modified to ensure additional margin existed to preclude failure. The results of the assessment are contained in this report.
Seña, Arlene C; Bachmann, Laura H; Hobbs, Marcia M
2014-06-01
Trichomonas vaginalis (TV) is a common sexually transmitted infection that can cause vaginitis, cervicitis and urethritis. Persistent and recurrent TV infections are frequent in women, potentially due to the lack of routine screening recommendations for this pathogen, the chronic nature of some infections, and drug resistance. Metronidazole and tinidazole are two oral drugs that are effective against trichomoniasis. There are few alternative treatment options for persons with a metronidazole allergy or treatment failure. Most TV isolates from women with treatment failures that have been analyzed for susceptibility testing in the United States have exhibited low-level metronidazole resistance, supporting the initial use of tinidazole for patients who fail metronidazole therapy. Several non-nitroimidazole drugs and other agents have demonstrated acceptable in vitro activity or cure rates in case reports for metronidazole-resistant trichomoniasis; however, clinical trials are imperative to evaluate their efficacy as alternative therapeutic regimens for this highly prevalent infection.
Microcircuit failure analysis using the SEM. [Scanning Electron Microscopes
NASA Technical Reports Server (NTRS)
Nicolas, D. P.
1974-01-01
The scanning electron microscope adds a new dimension to the knowledge that can be obtained from a failed microcircuit. When used with conventional techniques, SEM assists and clarifies the analysis, but it does not replace light microscopy. The most advantageous features for microcircuit analysis are long working distances and great depth of field. Manufacturer related failure modes of microcircuits are metallization defects, poor bonding, surface and particle contamination, and design and fabrication faults. User related failure modes are caused by abuse, such as overstress. The Physics of Failure Procedure followed by the Astrionics Laboratory in failure analysis is described, which is designed to obtain maximum information available from each step.
A case study in nonconformance and performance trend analysis
NASA Technical Reports Server (NTRS)
Maloy, Joseph E.; Newton, Coy P.
1990-01-01
As part of NASA's effort to develop an agency-wide approach to trend analysis, a pilot nonconformance and performance trending analysis study was conducted on the Space Shuttle auxiliary power unit (APU). The purpose of the study was to (1) demonstrate that nonconformance analysis can be used to identify repeating failures of a specific item (and the associated failure modes and causes) and (2) determine whether performance parameters could be analyzed and monitored to provide an indication of component or system degradation prior to failure. The nonconformance analysis of the APU did identify repeating component failures, which possibly could be reduced if key performance parameters were monitored and analyzed. The performance-trending analysis verified that the characteristics of hardware parameters can be effective in detecting degradation of hardware performance prior to failure.
Risk Analysis of Earth-Rock Dam Failures Based on Fuzzy Event Tree Method
Fu, Xiao; Gu, Chong-Shi; Su, Huai-Zhi; Qin, Xiang-Nan
2018-01-01
Earth-rock dams make up a large proportion of the dams in China, and their failures can induce great risks. In this paper, the risks associated with earth-rock dam failure are analyzed from two aspects: the probability of a dam failure and the resulting life loss. An event tree analysis method based on fuzzy set theory is proposed to calculate the dam failure probability. The life loss associated with dam failure is summarized and refined to be suitable for Chinese dams from previous studies. The proposed method and model are applied to one reservoir dam in Jiangxi province. Both engineering and non-engineering measures are proposed to reduce the risk. The risk analysis of the dam failure has essential significance for reducing dam failure probability and improving dam risk management level. PMID:29710824
Full-Field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites
NASA Technical Reports Server (NTRS)
Littell, Justin D.; Binienda, Wieslaw K.; Goldberg, Robert K.; Roberts, Gary D.
2008-01-01
Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape out of triaxial braided composite materials. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A more detailed investigation of deformation and failure processes in large-unit-cell-size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. This report presents some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12- and 24-k yarns and a 0 /+60 /-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed and correlations were made between these local failures and global composite deformation and strength.
Cheyne-stokes respiration in patients with heart failure.
AlDabal, Laila; BaHammam, Ahmed S
2010-01-01
Cheyne-Stokes respiration (CSR) is a form of central sleep-disordered breathing (SDB) in which there are cyclical fluctuations in breathing that lead to periods of central apneas/hypopnea, which alternate with periods of hyperpnea. The crescendo-decrescendo pattern of respiration in CSR is a compensation for the changing levels of blood oxygen and carbon dioxide. Severe congestive heart failure seems to be the most important risk factor for the development of CSR. A number of pathophysiologic changes, such as sleep disruption, arousals, hypoxemia-reoxygenation, hypercapnia/hypocapnia, and changes in intrathoracic pressure have harmful effects on the cardiovascular system, and the presence of CSR is associated with increased mortality and morbidity in subjects with variable degrees of heart failure. The management of CSR involves optimal control of underlying heart failure, oxygen therapy, and positive airway pressure support. In this review, we initially define and describe the epidemiology of central sleep apnea (CSA) and CSR, its pathogenesis, clinical presentation, diagnostic methods, and then discuss the recent developments in the management in patients with heart failure.
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
NASA Astrophysics Data System (ADS)
Spinner, Neil S.; Hinnant, Katherine M.; Mazurick, Ryan; Brandon, Andrew; Rose-Pehrsson, Susan L.; Tuttle, Steven G.
2016-04-01
Cylindrical 18650-type surrogate cells were designed and fabricated to mimic the thermophysical properties and behavior of active lithium-ion batteries. An internal jelly roll geometry consisting of alternating stainless steel and mica layers was created, and numerous techniques were used to estimate thermophysical properties. Surrogate cell density was measured to be 1593 ± 30 kg/m3, and heat capacity was found to be 727 ± 18 J/kg-K. Axial thermal conductivity was determined to be 5.1 ± 0.6 W/m-K, which was over an order of magnitude higher than radial thermal conductivity due to jelly roll anisotropy. Radial heating experiments were combined with numerical and analytical solutions to the time-dependent, radial heat conduction equation, and from the numerical method an additional estimate for heat capacity of 805 ± 23 J/kg-K was found. Using both heat capacities and analysis techniques, values for radial thermal conductivity were between 0.120 and 0.197 W/m-K. Under normal operating conditions, relatively low radial temperature distributions were observed; however, during extreme battery failure with a hexagonal cell package, instantaneous radial temperature distributions as high as 43-71 °C were seen. For a vertical cell package, even during adjacent cell failure, similar homogeneity in internal temperatures were observed, demonstrating thermal anisotropy.
Adsett, Julie; Morris, Norman; Kuys, Suzanne; Hwang, Rita; Mullins, Robert; Khatun, Mohsina; Paratz, Jennifer; Mudge, Alison
2017-06-01
Providing flexible models and a variety of exercise options are fundamental to supporting long-term exercise participation for patients with heart failure (HF). The aim of this pilot study was to determine the feasibility and efficacy of aquatic exercise training during a maintenance phase for a clinical heart failure population. In this 2 x 2 crossover design trial, individuals who had previously completed HF rehabilitation were randomised into either a land-based or aquatic training program once per week for six weeks, after which time they changed to the alternate exercise training protocol for an additional six weeks. Six-minute walk test (6MWT), grip strength, walk speed, and measures of balance were compared for the two training protocols. Fifty-one participants (43 males, mean age 69.2 yrs) contributed data for the analysis. Both groups maintained function during the follow-up period, however improvements in 6MWT were greater in the land-based training group (95% CI: 0.7, 22.5; p=0.038), by a mean difference of 10.8 metres. No significant difference was observed for other parameters when the two training protocols were compared. Attending an aquatic exercise program once per week is feasible for patients with stable HF and may provide a suitable option to maintain functional performance in select patients. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Mission Data System Java Edition Version 7
NASA Technical Reports Server (NTRS)
Reinholtz, William K.; Wagner, David A.
2013-01-01
The Mission Data System framework defines closed-loop control system abstractions from State Analysis including interfaces for state variables, goals, estimators, and controllers that can be adapted to implement a goal-oriented control system. The framework further provides an execution environment that includes a goal scheduler, execution engine, and fault monitor that support the expression of goal network activity plans. Using these frameworks, adapters can build a goal-oriented control system where activity coordination is verified before execution begins (plan time), and continually during execution. Plan failures including violations of safety constraints expressed in the plan can be handled through automatic re-planning. This version optimizes a number of key interfaces and features to minimize dependencies, performance overhead, and improve reliability. Fault diagnosis and real-time projection capabilities are incorporated. This version enhances earlier versions primarily through optimizations and quality improvements that raise the technology readiness level. Goals explicitly constrain system states over explicit time intervals to eliminate ambiguity about intent, as compared to command-oriented control that only implies persistent intent until another command is sent. A goal network scheduling and verification process ensures that all goals in the plan are achievable before starting execution. Goal failures at runtime can be detected (including predicted failures) and handled by adapted response logic. Responses can include plan repairs (try an alternate tactic to achieve the same goal), goal shedding, ignoring the fault, cancelling the plan, or safing the system.
Węgrzynowska-Teodorczyk, Kinga; Mozdzanowska, Dagmara; Josiak, Krystian; Siennicka, Agnieszka; Nowakowska, Katarzyna; Banasiak, Waldemar; Jankowska, Ewa A; Ponikowski, Piotr; Woźniewski, Marek
2016-08-01
The consequence of exercise intolerance for patients with heart failure is the difficulty climbing stairs. The two-minute step test is a test that reflects the activity of climbing stairs. The aim of the study design is to evaluate the applicability of the two-minute step test in an assessment of exercise tolerance in patients with heart failure and the association between the six-minute walk test and the two-minute step test. Participants in this study were 168 men with systolic heart failure (New York Heart Association (NYHA) class I-IV). In the study we used the two-minute step test, the six-minute walk test, the cardiopulmonary exercise test and isometric dynamometer armchair. Patients who performed more steps during the two-minute step test covered a longer distance during the six-minute walk test (r = 0.45). The quadriceps strength was correlated with the two-minute step test and the six-minute walk test (r = 0.61 and r = 0.48). The greater number of steps performed during the two-minute step test was associated with higher values of peak oxygen consumption (r = 0.33), ventilatory response to exercise slope (r = -0.17) and longer time of exercise during the cardiopulmonary exercise test (r = 0.34). Fatigue and leg fatigue were greater after the two-minute step test than the six-minute walk test whereas dyspnoea and blood pressure responses were similar. The two-minute step test is well tolerated by patients with heart failure and may thus be considered as an alternative for the six-minute walk test. © The European Society of Cardiology 2016.
Chong, Alexander Cm; Prohaska, Daniel J; Bye, Brian P
2017-05-01
With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity. Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained. Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber ® was used and at least one half-hitch was reversed. Knots tied with either Force Fiber ® or Orthocord ® showed 0% chance of knot slippage while knots tied with FiberWire ® or braided fishing line had about 10 and 30% knot slippage chances, respectively. A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future.
NASA Technical Reports Server (NTRS)
Behbehani, K.
1980-01-01
A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.
Analysing malaria drug trials on a per-individual or per-clone basis: a comparison of methods.
Jaki, Thomas; Parry, Alice; Winter, Katherine; Hastings, Ian
2013-07-30
There are a variety of methods used to estimate the effectiveness of antimalarial drugs in clinical trials, invariably on a per-person basis. A person, however, may have more than one malaria infection present at the time of treatment. We evaluate currently used methods for analysing malaria trials on a per-individual basis and introduce a novel method to estimate the cure rate on a per-infection (clone) basis. We used simulated and real data to highlight the differences of the various methods. We give special attention to classifying outcomes as cured, recrudescent (infections that never fully cleared) or ambiguous on the basis of genetic markers at three loci. To estimate cure rates on a per-clone basis, we used the genetic information within an individual before treatment to determine the number of clones present. We used the genetic information obtained at the time of treatment failure to classify clones as recrudescence or new infections. On the per-individual level, we find that the most accurate methods of classification label an individual as newly infected if all alleles are different at the beginning and at the time of failure and as a recrudescence if all or some alleles were the same. The most appropriate analysis method is survival analysis or alternatively for complete data/per-protocol analysis a proportion estimate that treats new infections as successes. We show that the analysis of drug effectiveness on a per-clone basis estimates the cure rate accurately and allows more detailed evaluation of the performance of the treatment. Copyright © 2012 John Wiley & Sons, Ltd.
Turned versus anodised dental implants: a meta-analysis.
Chrcanovic, B R; Albrektsson, T; Wennerberg, A
2016-09-01
The aim of this meta-analysis was to test the null hypothesis of no difference in the implant failure rates, marginal bone loss (MBL)and post-operative infection for patients being rehabilitated by turned versus anodised-surface implants, against the alternative hypothesis of a difference. An electronic search without time or language restrictions was undertaken in November 2015. Eligibility criteria included clinical human studies, either randomised or not. Thirty-eight publications were included. The results suggest a risk ratio of 2·82 (95% CI 1·95-4·06, P < 0·00001) for failure of turned implants, when compared to anodised-surface implants. Sensitivity analyses showed similar results when only the studies inserting implants in maxillae or mandibles were pooled. There were no statistically significant effects of turned implants on the MBL (mean difference-MD 0·02, 95%CI -0·16-0·20; P = 0·82) in comparison to anodised implants. The results of a meta-regression considering the follow-up period as a covariate suggested an increase of the MD with the increase in the follow-up time (MD increase 0·012 mm year(-1) ), however, without a statistical significance (P = 0·813). Due to lack of satisfactory information, meta-analysis for the outcome 'post-operative infection' was not performed. The results have to be interpreted with caution due to the presence of several confounding factors in the included studies. © 2016 John Wiley & Sons Ltd.
Remission of Grave's disease after oral anti-thyroid drug treatment.
Ishtiaq, Osama; Waseem, Sabiha; Haque, M Naeemul; Islam, Najmul; Jabbar, Abdul
2009-11-01
To evaluate remission rate of anti-thyroid drug treatment in patients with Grave's disease, and to study the factors associated with remission. A cross sectional study. The Endocrine Department of the Aga Khan University Hospital, Karachi from 1999 to 2000. Seventy four patients of Grave's disease were recruited who were prescribed medical treatment. Grave's disease was diagnosed in the presence of clinical and biochemical hyperthyroidism along with anti-microsomal (AMA) and anti-thyroglobulin antibodies (ATA) and thyroid scan. These patients were prescribed oral anti-thyroid drugs using titration regime and followed at 3, 6, 12 and 18 months. Patients were categorized into two groups: "remission group" and "treatment failure group" and results were compared using a chi-square test, t-test and logistic regression model with significance at p < 0.05. A majority of the patients were females (62.6%, n=46). During the follow-up period of 18 months, 41.9% patients went into remission. Univariate analysis showed that the initial free T4 level was significantly different (p < 0.05) in patients in remission and treatment failure groups. Multivariate analysis showed only initial free T4 level was a significant predictor of outcome. Positive AMA patients (n=27) had higher treatment failure (odds ratio: 2.55: 95%, CI 0.69 - 9:31), although the difference was not statistically significant (p = 0.13). Remission rates with oral anti-thyroid agents is markedly high. Patients should be offered alternate treatment options to those who do not enter remission during a period of 12-18 months of treatment, those who develop relapse, and those who have aggressive disease on initial presentation.
NASA Astrophysics Data System (ADS)
Milledge, David; Bellugi, Dino; McKean, Jim; Dietrich, William E.
2013-04-01
Current practice in regional-scale shallow landslide hazard assessment is to adopt a one-dimensional slope stability representation. Such a representation cannot produce discrete landslides and thus cannot make predictions on landslide size. Furthermore, one-dimensional approaches cannot include lateral effects, which are known to be important in defining instability. Here we derive an alternative model that accounts for lateral resistance by representing the forces acting on each margin of an unstable block of soil. We model boundary frictional resistances using 'at rest' earth pressure on the lateral sides, and 'active' and 'passive' pressure, using the log-spiral method, on the upslope and downslope margins. We represent root reinforcement on each margin assuming that root cohesion declines exponentially with soil depth. We test our model's ability to predict failure of an observed landslide where the relevant parameters are relatively well constrained and find that our model predicts failure at the observed location and predicts that larger or smaller failures conformal to the observed shape are indeed more stable. We use a sensitivity analysis of the model to show that lateral reinforcement sets a minimum landslide size, and that the additional strength at the downslope boundary results in optimal shapes that are longer in the downslope direction. However, reinforcement effects alone cannot fully explain the size or shape distributions of observed landslides, highlighting the importance of the spatial pattern of key parameters (e.g. pore water pressure and soil depth) at the watershed scale. The application of the model at this scale requires an efficient method to find unstable shapes among an exponential number of candidates. In this context, the model allows a more extensive examination of the controls on landslide size, shape and location.
Paeng, Jin Chul; Keam, Bhumsuk; Kim, Tae Min; Kim, Dong-Wan; Heo, Dae Seog
2018-01-01
Intratumoral heterogeneity has been suggested to be an important resistance mechanism leading to treatment failure. We hypothesized that radiologic images could be an alternative method for identification of tumor heterogeneity. We tested heterogeneity textural parameters on pretreatment FDG-PET/CT in order to assess the predictive value of target therapy. Recurred or metastatic non-small cell lung cancer (NSCLC) subjects with an activating EGFR mutation treated with either gefitinib or erlotinib were reviewed. An exploratory data set (n = 161) and a validation data set (n = 21) were evaluated, and eight parameters were selected for survival analysis. The optimal cutoff value was determined by the recursive partitioning method, and the predictive value was calculated using Harrell’s C-index. Univariate analysis revealed that all eight parameters showed an increased hazard ratio (HR) for progression-free survival (PFS). The highest HR was 6.41 (P<0.01) with co-occurrence (Co) entropy. Increased risk remained present after adjusting for initial stage, performance status (PS), and metabolic volume (MV) (aHR: 4.86, P<0.01). Textural parameters were found to have an incremental predictive value of early EGFR tyrosine kinase inhibitor (TKI) failure compared to that of the base model of the stage and PS (C-index 0.596 vs. 0.662, P = 0.02, by Co entropy). Heterogeneity textural parameters acquired from pretreatment FDG-PET/CT are highly predictive factors for PFS of EGFR TKI in EGFR-mutated NSCLC patients. These parameters are easily applicable to the identification of a subpopulation at increased risk of early EGFR TKI failure. Correlation to genomic alteration should be determined in future studies. PMID:29385152
Alternative methods of flexible base compaction acceptance.
DOT National Transportation Integrated Search
2012-05-01
In the Texas Department of Transportation, flexible base construction is governed by a series of stockpile : and field tests. A series of concerns with these existing methods, along with some premature failures in the : field, led to this project inv...
ANAEROBIC BIOREMEDIATION OF CHLORINATED ETHENES
The failure of what have been termed convential methods to reclaim contaminated environmental media has over the years lead to the interest and development of alternative technologies. One of these technologies is bioremediation, or the utilization of microbial agents to reduce ...
Independent Orbiter Assessment (IOA): Analysis of the crew equipment subsystem
NASA Technical Reports Server (NTRS)
Sinclair, Susan; Graham, L.; Richard, Bill; Saxon, H.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical (PCIs) items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results coresponding to the Orbiter crew equipment hardware are documented. The IOA analysis process utilized available crew equipment hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 352 failure modes analyzed, 78 were determined to be PCIs.
Zarriello, Phillip J.
2004-01-01
The Hydrologic Simulation ProgramFORTRAN (HSPF) model of the Ipswich River Basin previously developed by the U.S. Geological Survey was modified to evaluate the effects of the 2003 withdrawal permits and water-management alternatives on reservoir storage and yields of the Lynn, Peabody, and SalemBeverly water-supply systems. These systems obtain all or part of their water from the Ipswich River Basin. The HSPF model simulated the complex water budgets to the three supply systems, including effects of regulations that restrict withdrawals by the time of year, minimum streamflow thresholds, and the capacity of each system to pump water from the river. The 2003 permits restrict withdrawals from the Ipswich River between November 1 and May 31 to streamflows above a 1.0 cubic foot per second per square mile (ft3/s/mi2) threshold, to high flows between June 1 and October 31, and to a maximum annual volume. Yields and changes in reservoir storage over the 35-year simulation period (196195) were also evaluated for each system with a hypothetical low-capacity pump, alternative seasonal streamflow thresholds, and withdrawals that result in successive failures (depleted storage). The firm yields, the maximum yields that can be met during a severe drought, calculated for each water-supply system, under the 2003 permitted withdrawals, were 7.31 million gallons per day (Mgal/d) for the Lynn, 3.01 Mgal/d for the Peabody, and 7.98 Mgal/d for the SalemBeverly systems; these yields are 31, 49, and 21 percent less than their average 19982000 demands, respectively. The simulations with the same permit restrictions and a hypothetical low-capacity pump for each system resulted in slightly increased yields for the Lynn and SalemBeverly systems, but a slightly decreased yield for the Peabody system. Simulations to evaluate the effects of alternative streamflow thresholds on water supply indicated that firm yields were generally about twice as sensitive to decreases in the NovemberFebruary or MarchMay thresholds than to increases in these thresholds. Firm yields were also generally slightly less sensitive to changes in the NovemberFebruary than to changes in the MarchMay thresholds in the Peabody and SalemBeverly water-supply systems. Decreases in the JuneOctober streamflow threshold did not affect any of the system's firm yield. Simulations of withdrawal rates that resulted in successive near failures during the 196195 period indicated the tradeoff between increased yield and risks. The Lynn and Peabody systems were allowed to near failure up to six times. At the sixth near failure, yields of these systems increased to 10.18 and 4.43 Mgal/d, respectively; these rates increased the amount of water obtained from the Ipswich River Basin (relative to the firm-yield rate), as a percentage of average 19982000 demands, from 68 to 96 percent and from 51 to 75 percent, respectively. The SalemBeverly system was able to meet demands after the third near failure. Reservoir storage was depleted about 6 percent of the time at the withdrawal rate that caused the sixth near failure in the Lynn and Peabody system and about 3 percent of the time at the withdrawal rate that caused the third near failure in the SalemBeverly system. Supply systems are at greatest risk of failure from persistent droughts (lasting more than 1 year), but short-term droughts also present risks during the fall and winter when the supply systems are most vulnerable. Uncertainties in model performance, simplification of reservoir systems and their management, and the possibility of droughts of severity greater than simulated in this investigation underscore the fact that the firm yield calculated for each system cannot be considered a withdrawal rate that is absolutely fail-safe. Thus, the consequences of failure are an important consideration in the planning and management of these systems.
Interventions following hearing screening in adults: a systematic descriptive review.
Pronk, Marieke; Kramer, Sophia E; Davis, Adrian C; Stephens, Dafydd; Smith, Pauline A; Thodi, Chryssoula; Anteunis, Lucien J C; Parazzini, Marta; Grandori, Ferdinando
2011-09-01
Adult hearing screening may be a solution to the under-diagnosis and under-treatment of hearing loss in adults. Limited use and satisfaction with hearing aids indicate that consideration of alternative interventions following hearing screening may be needed. The primary aim of this study is to provide an overview of all intervention types that have been offered to adult (≥ 18 years) screen-failures. Systematic literature review. Articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, private libraries, and through reference checking. Of the initial 3027 papers obtained from the searches, a total of 37 were found to be eligible. The great majority of the screening programmes (i.e. 26) referred screen-failures to a hearing specialist without further rehabilitation being specified. Most of the others (i.e. seven) led to the provision of hearing aids. Four studies offered alternative interventions comprising communication programme elements (e.g. speechreading, hearing tactics) or advice on environmental aids. Interventions following hearing screening generally comprised referral to a hearing specialist or hearing aid rehabilitation. Some programmes offered alternative rehabilitation options. These may be valuable as an addition to or replacement of hearing aid rehabilitation. It is recommended that this be addressed in future research.
Wang, Juejin; Li, Guang; Yu, Dejie; Wong, Yuk Peng; Yong, Tan Fong; Liang, Mui Cheng; Liao, Ping; Foo, Roger; Hoppe, Uta C; Soong, Tuck Wah
2018-01-01
Recently, we reported that homozygous deletion of alternative exon 33 of Ca V 1.2 calcium channel in the mouse resulted in ventricular arrhythmias arising from increased Ca V 1.2 Δ33 I CaL current density in the cardiomyocytes. We wondered whether heterozygous deletion of exon 33 might produce cardiac phenotype in a dose-dependent manner, and whether the expression levels of RNA splicing factors known to regulate alternative splicing of exon 33 might change in human heart failure. Unexpectedly, we found that exon 33 +/- cardiomyocytes showed similar Ca V 1.2 channel properties as wild-type cardiomyocyte, even though Ca V 1.2 Δ33 channels exhibit a gain-in-function. In human hearts, we found that the mRNA level of splicing factor Rbfox1, but not Rbfox2, was downregulated in dilated cardiomyopathy, and CACNA1C mRNA level was dramatically decreased in the both of dilated and ischemic cardiomyopathy. These data imply Rbfox1 may be involved in the development of cardiomyopathies via regulating the alternative splicing of Ca V 1.2 exon 33. (149 words).
Cost-effectiveness analysis of timely dialysis referral after renal transplant failure in Spain.
Villa, Guillermo; Sánchez-Álvarez, Emilio; Cuervo, Jesús; Fernández-Ortiz, Lucía; Rebollo, Pablo; Ortega, Francisco
2012-08-16
A cost-effectiveness analysis of timely dialysis referral after renal transplant failure was undertaken from the perspective of the Public Administration. The current Spanish situation, where all the patients undergoing graft function loss are referred back to dialysis in a late manner, was compared to an ideal scenario where all the patients are timely referred. A Markov model was developed in which six health states were defined: hemodialysis, peritoneal dialysis, kidney transplantation, late referral hemodialysis, late referral peritoneal dialysis and death. The model carried out a simulation of the progression of renal disease for a hypothetical cohort of 1,000 patients aged 40, who were observed in a lifetime temporal horizon of 45 years. In depth sensitivity analyses were performed in order to ensure the robustness of the results obtained. Considering a discount rate of 3 %, timely referral showed an incremental cost of 211 €, compared to late referral. This cost increase was however a consequence of the incremental survival observed. The incremental effectiveness was 0.0087 quality-adjusted life years (QALY). When comparing both scenarios, an incremental cost-effectiveness ratio of 24,390 €/QALY was obtained, meaning that timely dialysis referral might be an efficient alternative if a willingness-to-pay threshold of 45,000 €/QALY is considered. This result proved to be independent of the proportion of late referral patients observed. The acceptance probability of timely referral was 61.90 %, while late referral was acceptable in 38.10 % of the simulations. If we however restrict the analysis to those situations not involving any loss of effectiveness, the acceptance probability of timely referral was 70.10 %, increasing twofold that of late referral (29.90 %). Timely dialysis referral after graft function loss might be an efficient alternative in Spain, improving both patients' survival rates and health-related quality of life at an affordable cost. Spanish Public Health authorities might therefore promote the inclusion of specific recommendations for this group of patients within the existing clinical guidelines.
Laboratory ultrasonic pulse velocity logging for determination of elastic properties from rock core
NASA Astrophysics Data System (ADS)
Blacklock, Natalie Erin
During the development of deep underground excavations spalling and rockbursting have been recognized as significant mechanisms of violent brittle failure. In order to predict whether violent brittle failure will occur, it is important to identify the location of stiffness transitions that are associated with geologic structure. One approach to identify the effect of geologic structures is to apply borehole geophysical tools ahead of the tunnel advance. Stiffness transitions can be identified using mechanical property analysis surveys that combine acoustic velocity and density data to calculate acoustic estimates of elastic moduli. However, logistical concerns arise since the approach must be conducted at the advancing tunnel face. As a result, borehole mechanical property analyses are rarely used. Within this context, laboratory ultrasonic pulse velocity testing has been proposed as a potential alternative to borehole mechanical property analysis since moving the analysis to the laboratory would remove logistical constraints and improve safety for the evaluators. In addition to the traditional method of conducting velocity testing along the core axis, two new methodologies for point-focused testing were developed across the core diameter, and indirectly along intact lengths of drill core. The indirect test procedure was implemented in a continuous ultrasonic velocity test program along 573m of drill core to identify key geologic structures that generated transitions in ultrasonic elastic moduli. The test program was successful at identifying the location of geologic contacts, igneous intrusions, faults and shear structures. Ultrasonic values of Young's modulus and bulk modulus were determined at locations of significant velocity transitions to examine the potential for energy storage and energy release. Comparison of results from different ultrasonic velocity test configurations determined that the indirect test configuration provided underestimates for values of Young's modulus. This indicated that the test procedure will require modifications to improve coupling of the transducers to the core surface. In order to assess whether laboratory testing can be an alternative to borehole surveys, laboratory velocity testing must be directly assessed with results from acoustic borehole logging. There is also potential for the laboratory velocity program to be used to assess small scale stiffness changes, differences in mineral composition and the degree of fracturing of drill core.
Barkoudah, Ebrahim; Kodali, Sindhura; Okoroh, Juliet; Sethi, Rosh; Hulten, Edward; Suemoto, Claudia; Bittencourt, Marcio Sommer
2015-05-01
Although diuretics are mainly used for the treatment of acute decompensated heart failure (ADHF), inadequate responses and complications have led to the use of extracorporeal ultrafiltration (UF) as an alternative strategy for reducing volume overloads in patients with ADHF. The aim of our study is to perform meta-analysis of the results obtained from studies on extracorporeal venous ultrafiltration and compare them with those of standard diuretic treatment for overload volume reduction in acute decompensated heart failure. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials databases were systematically searched using a pre‑specified criterion. Pooled estimates of outcomes after 48 h (weight change, serum creatinine level, and all-cause mortality) were computed using random effect models. Pooled weighted mean differences were calculated for weight loss and change in creatinine level, whereas a pooled risk ratio was used for the analysis of binary all-cause mortality outcome. A total of nine studies, involving 613 patients, met the eligibility criteria. The mean weight loss in patients who underwent UF therapy was 1.78 kg [95% Confidence Interval (CI): -2.65 to -0.91 kg; p < 0.001) more than those who received standard diuretic therapy. The post-intervention creatinine level, however, was not significantly different (mean change = -0.25 mg/dL; 95% CI: -0.56 to 0.06 mg/dL; p = 0.112). The risk of all-cause mortality persisted in patients treated with UF compared with patients treated with standard diuretics (Pooled RR = 1.00; 95% CI: 0.64-1.56; p = 0.993). Compared with standard diuretic therapy, UF treatment for overload volume reduction in individuals suffering from ADHF, resulted in significant reduction of body weight within 48 h. However, no significant decrease of serum creatinine level or reduction of all-cause mortality was observed.
Barkoudah, Ebrahim; Kodali, Sindhura; Okoroh, Juliet; Sethi, Rosh; Hulten, Edward; Suemoto, Claudia; Bittencourt, Marcio Sommer
2015-01-01
Introduction Although diuretics are mainly used for the treatment of acute decompensated heart failure (ADHF), inadequate responses and complications have led to the use of extracorporeal ultrafiltration (UF) as an alternative strategy for reducing volume overloads in patients with ADHF. Objective The aim of our study is to perform meta-analysis of the results obtained from studies on extracorporeal venous ultrafiltration and compare them with those of standard diuretic treatment for overload volume reduction in acute decompensated heart failure. Methods MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials databases were systematically searched using a pre‑specified criterion. Pooled estimates of outcomes after 48 h (weight change, serum creatinine level, and all-cause mortality) were computed using random effect models. Pooled weighted mean differences were calculated for weight loss and change in creatinine level, whereas a pooled risk ratio was used for the analysis of binary all-cause mortality outcome. Results A total of nine studies, involving 613 patients, met the eligibility criteria. The mean weight loss in patients who underwent UF therapy was 1.78 kg [95% Confidence Interval (CI): −2.65 to −0.91 kg; p < 0.001) more than those who received standard diuretic therapy. The post-intervention creatinine level, however, was not significantly different (mean change = −0.25 mg/dL; 95% CI: −0.56 to 0.06 mg/dL; p = 0.112). The risk of all-cause mortality persisted in patients treated with UF compared with patients treated with standard diuretics (Pooled RR = 1.00; 95% CI: 0.64–1.56; p = 0.993). Conclusion Compared with standard diuretic therapy, UF treatment for overload volume reduction in individuals suffering from ADHF, resulted in significant reduction of body weight within 48 h. However, no significant decrease of serum creatinine level or reduction of all-cause mortality was observed. PMID:25626761
Static and fatigue testing of full-scale fuselage panels fabricated using a Therm-X(R) process
NASA Technical Reports Server (NTRS)
Dinicola, Albert J.; Kassapoglou, Christos; Chou, Jack C.
1992-01-01
Large, curved, integrally stiffened composite panels representative of an aircraft fuselage structure were fabricated using a Therm-X process, an alternative concept to conventional two-sided hard tooling and contour vacuum bagging. Panels subsequently were tested under pure shear loading in both static and fatigue regimes to assess the adequacy of the manufacturing process, the effectiveness of damage tolerant design features co-cured with the structure, and the accuracy of finite element and closed-form predictions of postbuckling capability and failure load. Test results indicated the process yielded panels of high quality and increased damage tolerance through suppression of common failure modes such as skin-stiffener separation and frame-stiffener corner failure. Finite element analyses generally produced good predictions of postbuckled shape, and a global-local modelling technique yielded failure load predictions that were within 7% of the experimental mean.
Metallurgical failure analysis of MH-1A reactor core hold-down bolts. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hawthorne, J.R.; Watson, H.E.
1976-11-01
The Naval Research Laboratory has performed a failure analysis on two MH-1A reactor core hold-down bolts that broke in service. Adherence to fabrication specifications, post-service properties and possible causes of bolt failure were investigated. The bolt material was verified as 17-4PH precipitation hardening stainless steel. Measured bolt dimensions also were in accordance with fabrication drawing specifications. Bolt failure occurred in the region of a locking pin hole which reduced the bolt net section by 47 percent. The failure analysis indicates that the probable cause of failure was net section overloading resulting from a lateral bending force on the bolt. Themore » analysis indicates that net section overloading could also have resulted from combined tensile stresses (bolt preloading plus differential thermal expansion). Recommendations are made for improved bolting.« less
Stingray Failure Mode, Effects and Criticality Analysis: WEC Risk Registers
Ken Rhinefrank
2016-07-25
Analysis method to systematically identify all potential failure modes and their effects on the Stingray WEC system. This analysis is incorporated early in the development cycle such that the mitigation of the identified failure modes can be achieved cost effectively and efficiently. The FMECA can begin once there is enough detail to functions and failure modes of a given system, and its interfaces with other systems. The FMECA occurs coincidently with the design process and is an iterative process which allows for design changes to overcome deficiencies in the analysis.Risk Registers for major subsystems completed according to the methodology described in "Failure Mode Effects and Criticality Analysis Risk Reduction Program Plan.pdf" document below, in compliance with the DOE Risk Management Framework developed by NREL.
A health economic model of breakthrough pain.
Abernethy, Amy P; Wheeler, Jane L; Fortner, Barry V
2008-05-01
Although the literature adequately addresses the biologic basis, epidemiology, and management of breakthrough pain (BTP), it does not yet describe the full impact of this troubling, widespread phenomenon. The risks of a scanty understanding of BTP impact are failure to take preventive measures, underdiagnosis, undertreatment, and inappropriate management. Studies to date of the impact of BTP have followed pharmacoeconomic approaches. Building on prior efforts, this paper develops a more comprehensive health economic model that encompasses the full spectrum of costs, outcomes, risks and benefits associated with BTP and its management. The authors provide a rubric within which stakeholders--including providers, institutional leaders, administrators, and policymakers--can systematically balance the myriad potential effects of different treatment scenarios to guide decision-making. The paper then extends this model to the population level, providing a template for health economic analysis of alternate strategies for managing BTP, and delineating steps for accomplishing the analysis.
Competing Logics and Healthcare
Saks, Mike
2018-01-01
This paper offers a short commentary on the editorial by Mannion and Exworthy. The paper highlights the positive insights offered by their analysis into the tensions between the competing institutional logics of standardization and customization in healthcare, in part manifested in the conflict between managers and professionals, and endorses the plea of the authors for further research in this field. However, the editorial is criticized for its lack of a strong societal reference point, the comparative absence of focus on hybridization, and its failure to highlight structural factors impinging on the opposing logics in a broader neo-institutional framework. With reference to the Procrustean metaphor, it is argued that greater stress should be placed on the healthcare user in future health policy. Finally, the case of complementary and alternative medicine is set out which – while not explicitly mentioned in the editorial – most effectively concretizes the tensions at the heart of this analysis of healthcare. PMID:29626406
Androgen receptor modulation following combination exposure to brominated flame-retardants.
Kharlyngdoh, Joubert Banjop; Pradhan, Ajay; Olsson, Per-Erik
2018-03-19
Endocrine disrupting compounds can interfere with androgen receptor (AR) signaling and disrupt steroidogenesis leading to reproductive failure. The brominated flame-retardant (BFR) 1, 2-dibromo-4-(1, 2-dibromoethyl) cyclohexane (TBECH), is an agonist to human, chicken and zebrafish AR. Recently another group of alternative BFRs, allyl 2, 4, 6-tribromophenyl ether (ATE), and 2, 3-dibromopropyl 2, 4, 6-tribromophenyl ether (DPTE) along with its metabolite 2-bromoallyl 2, 4, 6-tribromophenyl ether (BATE) were identified as potent human AR antagonists. These alternative BFRs are present in the environment. The aim of the present study was to determine the effect of mixed exposures to the AR agonist and the AR antagonists at environmentally relevant concentrations. In vitro reporter luciferase assay showed that the AR antagonists, when present at concentration higher than TBECH, were able to inhibit TBECH-mediated AR activity. These AR antagonists also promoted AR nuclear translocation. In vitro gene expression analysis in the non-tumorigenic human prostate epithelial cell RWPE1 showed that TBECH induced AR target genes whereas DPTE repressed these genes. Further analysis of steroidogenic genes showed that TBECH up-regulated most of the genes while DPTE down-regulated the same genes. The results indicate that when TBECH and DPTE are present together they will antagonize each other, thereby reducing their individual effects.
Mathias, C J; Fosbraey, P; da Costa, D F; Thornley, A; Bannister, R
1986-01-01
Day and night urine volume, morning and evening body weight, and supine and sitting blood pressure were measured in five patients with chronic autonomic failure who were not receiving treatment with drugs. All had nocturnal polyuria, overnight weight loss, and a pronounced postural fall in blood pressure, with lowest levels in the morning. Desmopressin (2-4 micrograms given intramuscularly at 8 pm) reduced nocturnal polyuria, diminished overnight weight loss, raised supine blood pressure, and reduced the postural fall, especially in the morning, when patients were often at their worst. Desmopressin may be a useful alternative to, or may supplement, other forms of treatment in some patients with autonomic failure. PMID:3089519
Wong, Kam Cheong
2016-04-06
Clinicians use various clinical reasoning tools such as Ishikawa diagram to enhance their clinical experience and reasoning skills. Failure mode and effects analysis, which is an engineering methodology in origin, can be modified and applied to provide inputs into an Ishikawa diagram. The human biliary system is used to illustrate a modified failure mode and effects analysis. The anatomical and physiological processes of the biliary system are reviewed. Failure is defined as an abnormality caused by infective, inflammatory, obstructive, malignancy, autoimmune and other pathological processes. The potential failures, their effect(s), main clinical features, and investigation that can help a clinician to diagnose at each anatomical part and physiological process are reviewed and documented in a modified failure mode and effects analysis table. Relevant medical and surgical cases are retrieved from the medical literature and weaved into the table. A total of 80 clinical cases which are relevant to the modified failure mode and effects analysis for the human biliary system have been reviewed and weaved into a designated table. The table is the backbone and framework for further expansion. Reviewing and updating the table is an iterative and continual process. The relevant clinical features in the modified failure mode and effects analysis are then extracted and included in the relevant Ishikawa diagram. This article illustrates an application of engineering methodology in medicine, and it sows the seeds of potential cross-pollination between engineering and medicine. Establishing a modified failure mode and effects analysis can be a teamwork project or self-directed learning process, or a mix of both. Modified failure mode and effects analysis can be deployed to obtain inputs for an Ishikawa diagram which in turn can be used to enhance clinical experiences and clinical reasoning skills for clinicians, medical educators, and students.
Profits R Us: Notes on the Commercialization of America's Schools.
ERIC Educational Resources Information Center
Kaplan, George R.
1996-01-01
The phrase "school/business relationship" is misleading, since such "partnerships" encompass everything from genuine altruism to cynical exploitation of the "youth market." Corporate infiltration could signal privatization of public education, despite conspicuous failures like Education Alternatives, Inc. Instead of…
Normal Accident at Three Mile Island.
ERIC Educational Resources Information Center
Perrow, Charles
1981-01-01
Discusses some aspects of the accident at the Three Mile Island nuclear power plant. Explains a number of factors involved including the type of accident, warnings, design and equipment failure, operator error, and negative synergy. Presents alternatives to systems with catastrophic potential. (MK)
Risk management of key issues of FPSO
NASA Astrophysics Data System (ADS)
Sun, Liping; Sun, Hai
2012-12-01
Risk analysis of key systems have become a growing topic late of because of the development of offshore structures. Equipment failures of offloading system and fire accidents were analyzed based on the floating production, storage and offloading (FPSO) features. Fault tree analysis (FTA), and failure modes and effects analysis (FMEA) methods were examined based on information already researched on modules of relex reliability studio (RRS). Equipment failures were also analyzed qualitatively by establishing a fault tree and Boolean structure function based on the shortage of failure cases, statistical data, and risk control measures examined. Failure modes of fire accident were classified according to the different areas of fire occurrences during the FMEA process, using risk priority number (RPN) methods to evaluate their severity rank. The qualitative analysis of FTA gave the basic insight of forming the failure modes of FPSO offloading, and the fire FMEA gave the priorities and suggested processes. The research has practical importance for the security analysis problems of FPSO.
Analysis of Emergency Diesel Generators Failure Incidents in Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Hunt, Ronderio LaDavis
In early years of operation, emergency diesel generators have had a minimal rate of demand failures. Emergency diesel generators are designed to operate as a backup when the main source of electricity has been disrupted. As of late, EDGs (emergency diesel generators) have been failing at NPPs (nuclear power plants) around the United States causing either station blackouts or loss of onsite and offsite power. These failures occurred from a specific type called demand failures. This thesis evaluated the current problem that raised concern in the nuclear industry which was averaging 1 EDG demand failure/year in 1997 to having an excessive event of 4 EDG demand failure year which occurred in 2011. To determine the next occurrence of the extreme event and possible cause to an event of such happening, two analyses were conducted, the statistical and root cause analysis. Considering the statistical analysis in which an extreme event probability approach was applied to determine the next occurrence year of an excessive event as well as, the probability of that excessive event occurring. Using the root cause analysis in which the potential causes of the excessive event occurred by evaluating, the EDG manufacturers, aging, policy changes/ maintenance practices and failure components. The root cause analysis investigated the correlation between demand failure data and historical data. Final results from the statistical analysis showed expectations of an excessive event occurring in a fixed range of probability and a wider range of probability from the extreme event probability approach. The root-cause analysis of the demand failure data followed historical statistics for the EDG manufacturer, aging and policy changes/ maintenance practices but, indicated a possible cause regarding the excessive event with the failure components. Conclusions showed the next excessive demand failure year, prediction of the probability and the next occurrence year of such failures, with an acceptable confidence level, was difficult but, it was likely that this type of failure will not be a 100 year event. It was noticeable to see that the majority of the EDG demand failures occurred within the main components as of 2005. The overall analysis of this study provided from percentages, indicated that it would be appropriate to make the statement that the excessive event was caused by the overall age (wear and tear) of the Emergency Diesel Generators in Nuclear Power Plants. Future Work will be to better determine the return period of the excessive event once the occurrence has happened for a second time by implementing the extreme event probability approach.
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
NASA Technical Reports Server (NTRS)
Bogert, Philip B.; Satyanarayana, Arunkumar; Chunchu, Prasad B.
2006-01-01
Splitting, ultimate failure load and the damage path in center notched composite specimens subjected to in-plane tension loading are predicted using progressive failure analysis methodology. A 2-D Hashin-Rotem failure criterion is used in determining intra-laminar fiber and matrix failures. This progressive failure methodology has been implemented in the Abaqus/Explicit and Abaqus/Standard finite element codes through user written subroutines "VUMAT" and "USDFLD" respectively. A 2-D finite element model is used for predicting the intra-laminar damages. Analysis results obtained from the Abaqus/Explicit and Abaqus/Standard code show good agreement with experimental results. The importance of modeling delamination in progressive failure analysis methodology is recognized for future studies. The use of an explicit integration dynamics code for simple specimen geometry and static loading establishes a foundation for future analyses where complex loading and nonlinear dynamic interactions of damage and structure will necessitate it.
Quantitative method of medication system interface evaluation.
Pingenot, Alleene Anne; Shanteau, James; Pingenot, James D F
2007-01-01
The objective of this study was to develop a quantitative method of evaluating the user interface for medication system software. A detailed task analysis provided a description of user goals and essential activity. A structural fault analysis was used to develop a detailed description of the system interface. Nurses experienced with use of the system under evaluation provided estimates of failure rates for each point in this simplified fault tree. Means of estimated failure rates provided quantitative data for fault analysis. Authors note that, although failures of steps in the program were frequent, participants reported numerous methods of working around these failures so that overall system failure was rare. However, frequent process failure can affect the time required for processing medications, making a system inefficient. This method of interface analysis, called Software Efficiency Evaluation and Fault Identification Method, provides quantitative information with which prototypes can be compared and problems within an interface identified.
Probabilistic safety analysis of earth retaining structures during earthquakes
NASA Astrophysics Data System (ADS)
Grivas, D. A.; Souflis, C.
1982-07-01
A procedure is presented for determining the probability of failure of Earth retaining structures under static or seismic conditions. Four possible modes of failure (overturning, base sliding, bearing capacity, and overall sliding) are examined and their combined effect is evaluated with the aid of combinatorial analysis. The probability of failure is shown to be a more adequate measure of safety than the customary factor of safety. As Earth retaining structures may fail in four distinct modes, a system analysis can provide a single estimate for the possibility of failure. A Bayesian formulation of the safety retaining walls is found to provide an improved measure for the predicted probability of failure under seismic loading. The presented Bayesian analysis can account for the damage incurred to a retaining wall during an earthquake to provide an improved estimate for its probability of failure during future seismic events.
Independent Orbiter Assessment (IOA): Analysis of the auxiliary power unit
NASA Technical Reports Server (NTRS)
Barnes, J. E.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Auxiliary Power Unit (APU). The APUs are required to provide power to the Orbiter hydraulics systems during ascent and entry flight phases for aerosurface actuation, main engine gimballing, landing gear extension, and other vital functions. For analysis purposes, the APU system was broken down into ten functional subsystems. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. A preponderance of 1/1 criticality items were related to failures that allowed the hydrazine fuel to escape into the Orbiter aft compartment, creating a severe fire hazard, and failures that caused loss of the gas generator injector cooling system.
NASA Technical Reports Server (NTRS)
Roscoe, Stanley N.
1989-01-01
For better or worse, virtual imaging displays are with us in the form of narrow-angle combining-glass presentations, head-up displays (HUD), and head-mounted projections of wide-angle sensor-generated or computer-animated imagery (HMD). All military and civil aviation services and a large number of aerospace companies are involved in one way or another in a frantic competition to develop the best virtual imaging display system. The success or failure of major weapon systems hangs in the balance, and billions of dollars in potential business are at stake. Because of the degree to which national defense is committed to the perfection of virtual imaging displays, a brief consideration of their status, an investigation and analysis of their problems, and a search for realistic alternatives are long overdue.
Mod 1 wind turbine generator failure modes and effects analysis
NASA Technical Reports Server (NTRS)
1979-01-01
A failure modes and effects analysis (FMEA) was directed primarily at identifying those critical failure modes that would be hazardous to life or would result in major damage to the system. Each subsystem was approached from the top down, and broken down to successive lower levels where it appeared that the criticality of the failure mode warranted more detail analysis. The results were reviewed by specialists from outside the Mod 1 program, and corrective action taken wherever recommended.
Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio
2017-01-01
To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure ( P <0.05). Multivariate logistic regression analysis showed no statistically significant relationship ( P >0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant ( P <0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.
Tourkmani, Abdo Karim; Sánchez-Huerta, Valeria; De Wit, Guillermo; Martínez, Jaime D.; Mingo, David; Mahillo-Fernández, Ignacio; Jiménez-Alfaro, Ignacio
2017-01-01
AIM To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P<0.05). Multivariate logistic regression analysis showed no statistically significant relationship (P>0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y. PMID:28393027
Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.
Kallianos, Kimberly; Henry, Travis S; Yeghiazarians, Yerem; Zimmet, Jeffrey; Shunk, Kendrick A; Tseng, Elaine E; Mahadevan, Vaikom; Hope, Michael D
2017-03-15
Computed tomography angiography (CTA) is the test of choice for pre-procedure imaging of transcatheter aortic valve replacement (TAVR) candidates. The iodinated contrast required, however, increases the risk of renal dysfunction in patients with pre-existing renal failure. Ferumoxytol is a magnetic resonance imaging (MRI) contrast agent that can be used with renal failure. Its long vascular resonance time allows gated MRA sequences that approach CTA in image quality. We present respiratory and cardiac gated MRA enabled by ferumoxytol that can be post-processed in an analogous fashion to CTA. Seven patients with renal failure presenting for TAVR were imaged with respiratory and cardiac gated MRA at 3T using ferumoxtyol for contrast. Aortic annulus, root and peripheral access dimensions were calculated in a fashion identical to that used for CTA. Of these, 6 patients underwent a TAVR procedure and 5 had intraoperative valve assessment with transesophageal echocardiograph (TEE) using standard clinical protocols that employed both two- and three-dimensional techniques. Good correlation between MRA aortic annulus measurements and those from TEE were shown in 5 patients with mean annulus area of 392.4mm 2 (290-470 range) versus 374.1mm 2 (285-440 range), with a pairwise correlation coefficient of 0.92, p=0.029. All patients received Sapien valve implants (one 20mm, three 23mm, and two 26mm valves). Access decisions were guided by MRA with no complications. Annulus sizing resulted in no greater than trace/mild aortic regurgitation in all patients. Ferumoxytol MRA is a safe alternative to CTA in patients with renal failure for pre-TAVR analysis of the aortic root and peripheral access. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Milési, Christophe; Essouri, Sandrine; Pouyau, Robin; Liet, Jean-Michel; Afanetti, Mickael; Portefaix, Aurélie; Baleine, Julien; Durand, Sabine; Combes, Clémentine; Douillard, Aymeric; Cambonie, Gilles
2017-02-01
Nasal continuous positive airway pressure (nCPAP) is currently the gold standard for respiratory support for moderate to severe acute viral bronchiolitis (AVB). Although oxygen delivery via high flow nasal cannula (HFNC) is increasingly used, evidence of its efficacy and safety is lacking in infants. A randomized controlled trial was performed in five pediatric intensive care units (PICUs) to compare 7 cmH 2 O nCPAP with 2 L/kg/min oxygen therapy administered with HFNC in infants up to 6 months old with moderate to severe AVB. The primary endpoint was the percentage of failure within 24 h of randomization using prespecified criteria. To satisfy noninferiority, the failure rate of HFNC had to lie within 15% of the failure rate of nCPAP. Secondary outcomes included success rate after crossover, intubation rate, length of stay, and serious adverse events. From November 2014 to March 2015, 142 infants were included and equally distributed into groups. The risk difference of -19% (95% CI -35 to -3%) did not allow the conclusion of HFNC noninferiority (p = 0.707). Superiority analysis suggested a relative risk of success 1.63 (95% CI 1.02-2.63) higher with nCPAP. The success rate with the alternative respiratory support, intubation rate, durations of noninvasive and invasive ventilation, skin lesions, and length of PICU stay were comparable between groups. No patient had air leak syndrome or died. In young infants with moderate to severe AVB, initial management with HFNC did not have a failure rate similar to that of nCPAP. This clinical trial was recorded in the National Library of Medicine registry (NCT 02457013).
How Many Separable Sources? Model Selection In Independent Components Analysis
Woods, Roger P.; Hansen, Lars Kai; Strother, Stephen
2015-01-01
Unlike mixtures consisting solely of non-Gaussian sources, mixtures including two or more Gaussian components cannot be separated using standard independent components analysis methods that are based on higher order statistics and independent observations. The mixed Independent Components Analysis/Principal Components Analysis (mixed ICA/PCA) model described here accommodates one or more Gaussian components in the independent components analysis model and uses principal components analysis to characterize contributions from this inseparable Gaussian subspace. Information theory can then be used to select from among potential model categories with differing numbers of Gaussian components. Based on simulation studies, the assumptions and approximations underlying the Akaike Information Criterion do not hold in this setting, even with a very large number of observations. Cross-validation is a suitable, though computationally intensive alternative for model selection. Application of the algorithm is illustrated using Fisher's iris data set and Howells' craniometric data set. Mixed ICA/PCA is of potential interest in any field of scientific investigation where the authenticity of blindly separated non-Gaussian sources might otherwise be questionable. Failure of the Akaike Information Criterion in model selection also has relevance in traditional independent components analysis where all sources are assumed non-Gaussian. PMID:25811988
Characterization and optimization of spiral eddy current coils for in-situ crack detection
NASA Astrophysics Data System (ADS)
Mandache, Catalin
2018-03-01
In-situ condition-based maintenance is making strides in the aerospace industry and it is seen as an alternative to scheduled, time-based maintenance. With fatigue cracks originating from fastener holes as the main reason for structural failures, embedded eddy current coils are a viable non-invasive solution for their timely detection. The development and potential broad use of these coils are motivated by a few consistent arguments: (i) inspection of structures of complicated geometries and hard to access areas, that often require disassembly, (ii) alternative to regular inspection actions that could introduce inadvertent damage, (iii) for structures that have short inspection intervals, and (iv) for repaired structures where fastener holes contain bushings and prevent further bolt-hole inspections. Since the spiral coils are aiming at detecting radial cracks emanating from the fastener holes, their design parameters should allow for high inductance, low ohmic losses and power requirements, as well as optimal size and high sensitivity to discontinuities. In this study, flexible, surface conformable, spiral eddy current coils are empirically investigated on mock-up specimens, while numerical analysis is performed for their optimization and design improvement.
Grigg, Matthew J.; William, Timothy; Menon, Jayaram; Barber, Bridget E.; Wilkes, Christopher S.; Rajahram, Giri S.; Edstein, Michael D.; Auburn, Sarah; Price, Ric N.; Yeo, Tsin W.; Anstey, Nicholas M.
2016-01-01
Background. Chloroquine (CQ)-resistant Plasmodium vivax is increasingly reported throughout southeast Asia. The efficacy of CQ and alternative artemisinin combination therapies (ACTs) for vivax malaria in Malaysia is unknown. Methods. A randomized, controlled trial of CQ vs artesunate-mefloquine (AS-MQ) for uncomplicated vivax malaria was conducted in 3 district hospitals in Sabah, Malaysia. Primaquine was administered on day 28. The primary outcome was the cumulative risk of treatment failure by day 28 by Kaplan–Meier analysis. Results. From 2012 to 2014, 103 adults and children were enrolled. Treatment failure by day 28 was 61.1% (95% confidence interval [CI], 46.8–75.6) after CQ and 0% (95% CI, 0–.08) following AS-MQ (P < .001), of which 8.2% (95% CI, 2.5–9.6) were early treatment failures. All patients with treatment failure had therapeutic plasma CQ concentrations at day 7. Compared with CQ, AS-MQ was associated with faster parasite clearance (normalized clearance slope, 0.311 vs 0.127; P < .001) and fever clearance (mean, 19.0 vs 37.7 hours; P = .001) and with lower risk of anemia at day 28 (odds ratio = 3.7; 95% CI, 1.5–9.3; P = .005). Gametocytes were present at day 28 in 23.8% (10/42) of patients following CQ vs none with AS-MQ (P < .001). AS-MQ resulted in lower bed occupancy: 4037 vs 6510 days/1000 patients (incidence rate ratio 0.62; 95% CI, .60–.65; P < .001). One patient developed severe anemia not regarded as related to their AS-MQ treatment. Conclusions. High-grade CQ-resistant P. vivax is prevalent in eastern Malaysia. AS-MQ is an efficacious ACT for all malaria species. Wider CQ-efficacy surveillance is needed in vivax-endemic regions with earlier replacement with ACT when treatment failure is detected. Clinical Trials Registration. NCT01708876. PMID:27107287
Grigg, Matthew J; William, Timothy; Menon, Jayaram; Barber, Bridget E; Wilkes, Christopher S; Rajahram, Giri S; Edstein, Michael D; Auburn, Sarah; Price, Ric N; Yeo, Tsin W; Anstey, Nicholas M
2016-06-01
Chloroquine (CQ)-resistant Plasmodium vivax is increasingly reported throughout southeast Asia. The efficacy of CQ and alternative artemisinin combination therapies (ACTs) for vivax malaria in Malaysia is unknown. A randomized, controlled trial of CQ vs artesunate-mefloquine (AS-MQ) for uncomplicated vivax malaria was conducted in 3 district hospitals in Sabah, Malaysia. Primaquine was administered on day 28. The primary outcome was the cumulative risk of treatment failure by day 28 by Kaplan-Meier analysis. From 2012 to 2014, 103 adults and children were enrolled. Treatment failure by day 28 was 61.1% (95% confidence interval [CI], 46.8-75.6) after CQ and 0% (95% CI, 0-.08) following AS-MQ (P < .001), of which 8.2% (95% CI, 2.5-9.6) were early treatment failures. All patients with treatment failure had therapeutic plasma CQ concentrations at day 7. Compared with CQ, AS-MQ was associated with faster parasite clearance (normalized clearance slope, 0.311 vs 0.127; P < .001) and fever clearance (mean, 19.0 vs 37.7 hours; P =001) and with lower risk of anemia at day 28 (odds ratio = 3.7; 95% CI, 1.5-9.3; P =005). Gametocytes were present at day 28 in 23.8% (10/42) of patients following CQ vs none with AS-MQ (P < .001). AS-MQ resulted in lower bed occupancy: 4037 vs 6510 days/1000 patients (incidence rate ratio 0.62; 95% CI, .60-.65; P < .001). One patient developed severe anemia not regarded as related to their AS-MQ treatment. High-grade CQ-resistant P. vivax is prevalent in eastern Malaysia. AS-MQ is an efficacious ACT for all malaria species. Wider CQ-efficacy surveillance is needed in vivax-endemic regions with earlier replacement with ACT when treatment failure is detected.Clinical Trials Registration NCT01708876. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.
Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann
2015-01-01
To test the null hypothesis of no difference in the implant failure rates, postoperative infection and marginal bone loss for the insertion of dental implants in fresh extraction sockets compared to the insertion in healed sites, against the alternative hypothesis of a difference. Main search terms used in combination: dental implant, oral implant, resh extraction socket, immediate placement, immediate insertion, immediate implant. An electronic search was undertaken in July/2014, in PubMed, Web of Science, Cochrane Oral Health Group Trials Register plus hand-searching. Eligibility criteria included clinical human studies, either randomized or not. The search strategy resulted in 73 publications, with 8,241 implants inserted in sockets (330 failures, 4.00%), and 19,410 in healed sites (599 failures, 3.09%). It is suggested that the insertion of implants in fresh extraction sockets affects the failure rates (RR 1.58, 95% CI 1.27-1.95, P<0.0001). The difference was not statistically significant when studies evaluating implants inserted in maxillae or in mandibles were pooled, or when the studies using implants to rehabilitate patients with full-arch prostheses were pooled; however, it was significant for the studies that rehabilitated patients with implant-supported single crowns and for the controlled studies. There was no apparent significant effect on the occurrence of postoperative infection or on the magnitude of marginal bone loss. The results should be interpreted with caution due to the potential for biases and to the presence of uncontrolled confounding factors in the included studies, most of them not randomized. The question whether immediate implants are more at risk for failure than implants placed in mature bone has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine techniques and eliminate unnecessary procedures. This would form a basis for optimum treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio
2018-05-25
As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p <.001) for all comparisons except for Hand Innovations vs. Zimmer bending stiffness post fatigue (p = .197). the significant higher load to failure of the titanium plate, makes it indicated for patients with higher functional requirements or at higher risk of trauma in the post-operative period. The CFR-PEEK plate showed material-specific disadvantages, represented by little tolerance to plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.
Diagnosis of Fanconi anemia in patients with bone marrow failure
Pinto, Fernando O.; Leblanc, Thierry; Chamousset, Delphine; Le Roux, Gwenaelle; Brethon, Benoit; Cassinat, Bruno; Larghero, Jérôme; de Villartay, Jean-Pierre; Stoppa-Lyonnet, Dominique; Baruchel, André; Socié, Gérard; Gluckman, Eliane; Soulier, Jean
2009-01-01
Background Patients with bone marrow failure and undiagnosed underlying Fanconi anemia may experience major toxicity if given standard-dose conditioning regimens for hematopoietic stem cell transplant. Due to clinical variability and/or potential emergence of genetic reversion with hematopoietic somatic mosaicism, a straightforward Fanconi anemia diagnosis can be difficult to make, and diagnostic strategies combining different assays in addition to classical breakage tests in blood may be needed. Design and Methods We evaluated Fanconi anemia diagnosis on blood lymphocytes and skin fibroblasts from a cohort of 87 bone marrow failure patients (55 children and 32 adults) with no obvious full clinical picture of Fanconi anemia, by performing a combination of chromosomal breakage tests, FANCD2-monoubiquitination assays, a new flow cytometry-based mitomycin C sensitivity test in fibroblasts, and, when Fanconi anemia was diagnosed, complementation group and mutation analyses. The mitomycin C sensitivity test in fibroblasts was validated on control Fanconi anemia and non-Fanconi anemia samples, including other chromosomal instability disorders. Results When this diagnosis strategy was applied to the cohort of bone marrow failure patients, 7 Fanconi anemia patients were found (3 children and 4 adults). Classical chromosomal breakage tests in blood detected 4, but analyses on fibroblasts were necessary to diagnose 3 more patients with hematopoietic somatic mosaicism. Importantly, Fanconi anemia was excluded in all the other patients who were fully evaluated. Conclusions In this large cohort of patients with bone marrow failure our results confirmed that when any clinical/biological suspicion of Fanconi anemia remains after chromosome breakage tests in blood, based on physical examination, history or inconclusive results, then further evaluation including fibroblast analysis should be made. For that purpose, the flow-based mitomycin C sensitivity test here described proved to be a reliable alternative method to evaluate Fanconi anemia phenotype in fibroblasts. This global strategy allowed early and accurate confirmation or rejection of Fanconi anemia diagnosis with immediate clinical impact for those who underwent hematopoietic stem cell transplant. PMID:19278965
Consequences of avoiding β-lactams in patients with β-lactam allergies.
Jeffres, Meghan N; Narayanan, Prasanna P; Shuster, Jerrica E; Schramm, Garrett E
2016-04-01
The choice of empiric antibiotics for the treatment of gram-negative bacilli (GNB) bloodstream infections (BSIs) in patients presenting with a β-lactam (BL) allergy is often a difficult decision given that these agents are first-line treatment in many guidelines. We sought to compare rates of clinical failure between patients with a history of BL allergy who received either a BL or a non-β-lactam (NBL). Adult patients with a past medical history of BL allergy and receipt of antibiotics for treatment of a GNB BSI were included from 3 academic medical centers. Treatment groups were classified as BL or NBL groups based on the empiric antibiotics received. Clinical failure was assessed 72 to 96 hours after initiation of empiric antibiotics. Hypersensitivity reactions during receipt of antibiotic therapy for the index BSI were recorded. A total of 552 patients were included for analysis: 433 patients in the BL group and 119 patients in the NBL group. Clinical failure was higher in the NBL group compared with the BL group (38.7% vs 27.4%, P = .030). The most common cause of clinical failure was a temperature of greater than 38.0°C 72 to 96 hours after receipt of empiric antibiotics (NBL group: 22.7% vs BL group: 13.9%, P = .016). Hypersensitivity occurred in 16 (2.9%) of 552 patients. Thirteen (2.5%) of 552 patients experiencing hypersensitivity reactions were exposed to a BL during treatment for GNB BSI. Among patients with a BL allergy, use of BL antibiotics is associated with a lower rate of clinical failure. The low rate of hypersensitivity provides further evidence about the risk of cross-reactivity between BL classes. These results support the practice of using a BL from an alternative class for patients in need of gram-negative antibiotic coverage. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Martini, Thomas; Wezel, Felix; Löbig, Niklas; Mitterberger, Michael J; Colleselli, Daniela
2017-08-01
Background Adjuvant Bacillus Calmette-Guérin (BCG) intravesical instillation is the recommended standard treatment in patients with high-risk non-muscle-invasive bladder cancer (NMIBC). However, a significant proportion of patients fail treatment, and radical cystectomy (RC) is the subsequent gold standard. On the other hand, there is an unmet need for conservative alternatives for patients who are unfit or unwilling to undergo surgery. This study aimed to identify conservative treatment options in NMIBC patients after BCG failure. Material and Methods We performed a systematic search in the databases Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE, including all randomised controlled trials (RCTs), quasi-RCTs and single-arm studies, in which patients with NMIBC were treated with second-line intravesical or systemic therapy after BCG failure. A minimum of eight patients were included in each treatment arm. Full papers were restricted to English language. Literature research and data analysis were assessed independently by two reviewers. Data on treatment response, recurrence, time to recurrence, progression and rate of cystectomy were collected and analysed. Results This systematic review included 42 publications with a total of 3521 patients (2371 BCG failures). Valrubicin, taxanes, gemcitabine, combination chemotherapy, thermochemotherapy, photodynamic therapy, combination of BCG and interferon and immunotherapies or targeted therapies were identified as conservative treatment options. For taxanes, gemcitabine and thermochemotherapy there is the highest evidence for a clinical meaningful response with minor toxicities. Conclusions Despite some promising response rates for taxanes, gemcitabine or thermochemotherapy, an evidence-based recommendation for treatment options superior to RC in patients failing BCG therapy cannot be made. The definition of BCG failure is still inconsistent and heterogeneous outcomes in patients with BCG failure have been reported. In order to identify effective conservative therapy options in patients failing BCG therapy, prospective trials with a standardised trial design are needed. © Georg Thieme Verlag KG Stuttgart · New York.
Mechanisms, predictors, and trends of electrical failure of Riata leads.
Cheung, Jim W; Al-Kazaz, Mohamed; Thomas, George; Liu, Christopher F; Ip, James E; Bender, Seth R; Siddiqi, Faisal K; Markowitz, Steven M; Lerman, Bruce B
2013-10-01
Riata and Riata ST implantable cardioverter-defibrillator leads have been shown to be prone to structural and electrical failure. To determine predictors, mechanisms, and temporal patterns of Riata/ST lead electrical failure. All 314 patients who underwent Riata/ST lead implantation at our institution with greater than or equal to 90 days of follow-up were studied. The Kaplan-Meier analysis of lead survival was performed. Results from the returned product analysis of explanted leads with electrical lead failure were recorded. During a median follow-up of 4.1 years, the Riata lead electrical failure rate was 6.6%. The rate of externalized conductors among failed leads was 57%. The engineering analysis of 10 explanted leads revealed 5 (50%) leads with electrical failure owing to breach of ethylene tetrafluoroethylene conductor coating. Female gender (hazard ratio 2.7; 95% confidence interval 1.1-6.7; P = .04) and age (hazard ratio 0.95; 95% confidence interval 0.92-0.97; P < .001) were multivariate predictors of lead failure. By using log-log analysis, we noted that the rate of Riata lead failure initially increased exponentially with a power of 2.1 but leads surviving past 4 years had a linear pattern of lead failure with a power of 1.0. Younger age and female gender are independent predictors of Riata lead failure. Loss of integrity of conductor cables with ethylene tetrafluoroethylene coating is an important mode of electrical failure of the Riata lead. Further study of Riata lead failure trends is warranted to guide lead management. © 2013 Heart Rhythm Society. All rights reserved.
Power degradation and reliability study of high-power laser bars at quasi-CW operation
NASA Astrophysics Data System (ADS)
Zhang, Haoyu; Fan, Yong; Liu, Hui; Wang, Jingwei; Zah, Chungen; Liu, Xingsheng
2017-02-01
The solid state laser relies on the laser diode (LD) pumping array. Typically for high peak power quasi-CW (QCW) operation, both energy output per pulse and long term reliability are critical. With the improved bonding technique, specially Indium-free bonded diode laser bars, most of the device failures were caused by failure within laser diode itself (wearout failure), which are induced from dark line defect (DLD), bulk failure, point defect generation, facet mirror damage and etc. Measuring the reliability of LD under QCW condition will take a rather long time. Alternatively, an accelerating model could be a quicker way to estimate the LD life time under QCW operation. In this report, diode laser bars were mounted on micro channel cooler (MCC) and operated under QCW condition with different current densities and junction temperature (Tj ). The junction temperature is varied by modulating pulse width and repetition frequency. The major concern here is the power degradation due to the facet failure. Reliability models of QCW and its corresponding failures are studied. In conclusion, QCW accelerated life-time model is discussed, with a few variable parameters. The model is compared with CW model to find their relationship.
[Review of the knowledge on acute kidney failure in the critical patient].
Romero García, M; Delgado Hito, P; de la Cueva Ariza, L
2013-01-01
Acute renal failure affects from 1% to 25% of patients admitted to intensive care units. These figures vary depending on the population studied and criteria. The complications of acute renal failure (fluid overload, metabolic acidosis, hyperkalemia, bleeding) are treated. However, mortality remains high despite the technological advances of recent years because acute renal failure is usually associated with sepsis, respiratory failure, serious injury, surgical complications or consumption coagulopathy. Mortality ranges from 30% to 90%. Although there is no universally accepted definition, the RIFLE classification gives us an operational tool to define the degree of acute renal failure and to standardize the initiation of renal replacement techniques as well as to evaluate the results. Therefore, nurses working within the intensive care unit must be familiar with this disease, with its treatment (drug or alternative) and with the prevention of possible complications. Equally, they must be capable of detecting the manifestations of dependency each one of the basic needs and to be able to identify the collaboration problems in order to achieve an individualized care plan. Copyright © 2012 Elsevier España, S.L. y SEEIUC. All rights reserved.
Risk analysis by FMEA as an element of analytical validation.
van Leeuwen, J F; Nauta, M J; de Kaste, D; Odekerken-Rombouts, Y M C F; Oldenhof, M T; Vredenbregt, M J; Barends, D M
2009-12-05
We subjected a Near-Infrared (NIR) analytical procedure used for screening drugs on authenticity to a Failure Mode and Effects Analysis (FMEA), including technical risks as well as risks related to human failure. An FMEA team broke down the NIR analytical method into process steps and identified possible failure modes for each step. Each failure mode was ranked on estimated frequency of occurrence (O), probability that the failure would remain undetected later in the process (D) and severity (S), each on a scale of 1-10. Human errors turned out to be the most common cause of failure modes. Failure risks were calculated by Risk Priority Numbers (RPNs)=O x D x S. Failure modes with the highest RPN scores were subjected to corrective actions and the FMEA was repeated, showing reductions in RPN scores and resulting in improvement indices up to 5.0. We recommend risk analysis as an addition to the usual analytical validation, as the FMEA enabled us to detect previously unidentified risks.
Occipital GABA correlates with cognitive failures in daily life.
Sandberg, Kristian; Blicher, Jakob Udby; Dong, Mia Yuan; Rees, Geraint; Near, Jamie; Kanai, Ryota
2014-02-15
The brain has limited capacity, and so selective attention enhances relevant incoming information while suppressing irrelevant information. This process is not always successful, and the frequency of such cognitive failures varies to a large extent between individuals. Here we hypothesised that individual differences in cognitive failures might be reflected in inhibitory processing in the sensory cortex. To test this hypothesis, we measured GABA in human visual cortex using MR spectroscopy and found a negative correlation between occipital GABA (GABA+/Cr ratio) and cognitive failures as measured by an established cognitive failures questionnaire (CFQ). For a second site in parietal cortex, no correlation between CFQ score and GABA+/Cr ratio was found, thus establishing the regional specificity of the link between occipital GABA and cognitive failures. We further found that grey matter volume in the left superior parietal lobule (SPL) correlated with cognitive failures independently from the impact of occipital GABA and together, occipital GABA and SPL grey matter volume statistically explained around 50% of the individual variability in daily cognitive failures. We speculate that the amount of GABA in sensory areas may reflect the potential capacity to selectively suppress irrelevant information already at the sensory level, or alternatively that GABA influences the specificity of neural representations in visual cortex thus improving the effectiveness of successful attentional modulation. © 2013. Published by Elsevier Inc. All rights reserved.
Capucci, Alessandro; De Simone, Antonio; Luzi, Mario; Calvi, Valeria; Stabile, Giuseppe; D'Onofrio, Antonio; Maffei, Simone; Leoni, Loira; Morani, Giovanni; Sangiuolo, Raffaele; Amellone, Claudia; Checchinato, Catia; Ammendola, Ernesto; Buja, Gianfranco
2017-09-01
Heart failure (HF) patients with implantable cardioverter-defibrillators (ICD) require admissions for disease management and out-patient visits for disease management and assessment of device performance. These admissions place a significant burden on the National Health Service. Remote monitoring (RM) is an effective alternative to frequent hospital visits. The EFFECT study was a multicentre observational investigation aiming to evaluate the clinical effectiveness of RM compared with in-office visits standard management (SM). The present analysis is an economic evaluation of the results of the EFFECT trial. The present analysis considered the direct consumption of healthcare resources over 12-month follow-up. Standard tariffs were applied to hospitalizations, in-office visits and remote device interrogations. Economic comparisons were also carried out by means of propensity score (PS) analysis to take into account the lack of randomization in the study design. The analysis involved 858 patients with ICD or CRT-D. Of these, 401 (47%) were followed up via an SM approach, while 457 (53%) were assigned to RM. The rate of hospitalizations was 0.27/year in the SM group and 0.16/year in the RM group (risk reduction =0.59; P = 0.0004). In the non-adjusted analysis, the annual cost for each patient was €817 in the SM group and €604 in the RM group (P = 0.014). Propensity score analysis, in which 292 RM patients were matched with 292 SM patients, confirmed the results of the non-adjusted analysis (€872 in the SM group vs. €757 in the RM group; P < 0.0001). There is a reduction in direct healthcare costs of RM for HF patients with ICDs, particularly CRT-D, compared with standard monitoring. http://clinicaltrials.gov/Identifier, NCT01723865. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.
ELECTRONIC COMPONENT COOLING ALTERNATIVES: COMPRESSED AIR AND LIQUID NITROGEN
The goal of this study was to evaluate topics used to troubleshoot circuit boards with known or suspected thermally intermittent components. Failure modes for thermally intermittent components are typically mechanical defects, such as cracks in solder paths or joints, or broken b...
Thermal design, analysis and comparison on three concepts of space solar power satellite
NASA Astrophysics Data System (ADS)
Yang, Chen; Hou, Xinbin; Wang, Li
2017-08-01
Space solar power satellites (SSPS) have been widely studied as systems for collecting solar energy in space and transmitting it wirelessly to earth. A previously designed planar SSPS concept collects solar power in two huge arrays and then transmits it through one side of the power-conduction joint to the antenna. However, the system's one group of power-conduction joints may induce a single point of failure. As an SSPS concept, the module symmetrical concentrator (MSC) architecture has many advantages. This architecture can help avoid the need for a large, potentially failure-prone conductive rotating joint and limit wiring mass. However, the thermal control system has severely restricted the rapid development of MSC, especially in the sandwich module. Because of the synchronous existence of five suns concentration and solar external heat flux, the sandwich module will have a very high temperature, which will surpass the permissible temperature of the solar cells. Recently, an alternate multi-rotary joints (MR) SSPS concept was designed by the China Academy of Space Technology (CAST). This system has multiple joints to avoid the problem of a single point of failure. Meanwhile, this concept has another advantage for reducing the high power and heat removal in joints. It is well known to us that, because of the huge external flux in SSPS, the thermal management sub-system is an important component that cannot be neglected. Based on the three SSPS concepts, this study investigated the thermal design and analysis of a 1-km, gigawatt-level transmitting antenna in SSPS. This study compares the thermal management sub-systems of power-conduction joints in planar and MR SSPS. Moreover, the study considers three classic thermal control architectures of the MSC's sandwich module: tile, step, and separation. The study also presents an elaborate parameter design, analysis and discussion of step architecture. Finally, the results show the thermal characteristics of each SSPS concept, and the three concepts are compared. The design layouts, analysis results and parameter discussions of the thermal management sub-system proposed in this study can help inform future SSPS thermal designs.
Immunity-based detection, identification, and evaluation of aircraft sub-system failures
NASA Astrophysics Data System (ADS)
Moncayo, Hever Y.
This thesis describes the design, development, and flight-simulation testing of an integrated Artificial Immune System (AIS) for detection, identification, and evaluation of a wide variety of sensor, actuator, propulsion, and structural failures/damages including the prediction of the achievable states and other limitations on performance and handling qualities. The AIS scheme achieves high detection rate and low number of false alarms for all the failure categories considered. Data collected using a motion-based flight simulator are used to define the self for an extended sub-region of the flight envelope. The NASA IFCS F-15 research aircraft model is used and represents a supersonic fighter which include model following adaptive control laws based on non-linear dynamic inversion and artificial neural network augmentation. The flight simulation tests are designed to analyze and demonstrate the performance of the immunity-based aircraft failure detection, identification and evaluation (FDIE) scheme. A general robustness analysis is also presented by determining the achievable limits for a desired performance in the presence of atmospheric perturbations. For the purpose of this work, the integrated AIS scheme is implemented based on three main components. The first component performs the detection when one of the considered failures is present in the system. The second component consists in the identification of the failure category and the classification according to the failed element. During the third phase a general evaluation of the failure is performed with the estimation of the magnitude/severity of the failure and the prediction of its effect on reducing the flight envelope of the aircraft system. Solutions and alternatives to specific design issues of the AIS scheme, such as data clustering and empty space optimization, data fusion and duplication removal, definition of features, dimensionality reduction, and selection of cluster/detector shape are also analyzed in this thesis. They showed to have an important effect on detection performance and are a critical aspect when designing the configuration of the AIS. The results presented in this thesis show that the AIS paradigm addresses directly the complexity and multi-dimensionality associated with a damaged aircraft dynamic response and provides the tools necessary for a comprehensive/integrated solution to the FDIE problem. Excellent detection, identification, and evaluation performance has been recorded for all types of failures considered. The implementation of the proposed AIS-based scheme can potentially have a significant impact on the safety of aircraft operation. The output information obtained from the scheme will be useful to increase pilot situational awareness and determine automated compensation.
Reliability Evaluation of Machine Center Components Based on Cascading Failure Analysis
NASA Astrophysics Data System (ADS)
Zhang, Ying-Zhi; Liu, Jin-Tong; Shen, Gui-Xiang; Long, Zhe; Sun, Shu-Guang
2017-07-01
In order to rectify the problems that the component reliability model exhibits deviation, and the evaluation result is low due to the overlook of failure propagation in traditional reliability evaluation of machine center components, a new reliability evaluation method based on cascading failure analysis and the failure influenced degree assessment is proposed. A direct graph model of cascading failure among components is established according to cascading failure mechanism analysis and graph theory. The failure influenced degrees of the system components are assessed by the adjacency matrix and its transposition, combined with the Pagerank algorithm. Based on the comprehensive failure probability function and total probability formula, the inherent failure probability function is determined to realize the reliability evaluation of the system components. Finally, the method is applied to a machine center, it shows the following: 1) The reliability evaluation values of the proposed method are at least 2.5% higher than those of the traditional method; 2) The difference between the comprehensive and inherent reliability of the system component presents a positive correlation with the failure influenced degree of the system component, which provides a theoretical basis for reliability allocation of machine center system.
Independent Orbiter Assessment (IOA): Analysis of the pyrotechnics subsystem
NASA Technical Reports Server (NTRS)
Robinson, W. W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Pyrotechnics hardware. The IOA analysis process utilized available pyrotechnics hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
High-Temperature Graphitization Failure of Primary Superheater Tube
NASA Astrophysics Data System (ADS)
Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.
2015-12-01
Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.
Failure Analysis and Mechanisms of Failure of Fibrous Composite Structures
NASA Technical Reports Server (NTRS)
Noor, A. K. (Compiler); Shuart, M. J. (Compiler); Starnes, J. H., Jr. (Compiler); Williams, J. G. (Compiler)
1983-01-01
The state of the art of failure analysis and current design practices, especially as applied to the use of fibrous composite materials in aircraft structures is discussed. Deficiencies in these technologies are identified, as are directions for future research.
NASA Astrophysics Data System (ADS)
Waas, Anthony M.
A series of experiments were performed to determine the mechanism of failure in compressively loaded laminated plates in the presence of stress gradients generated by a circular cutout. Real time holographic interferometry and in-situ photomicrography of the hole surface, were used to observe the progression of failure.The test specimens are multi-layered composite flat plates, which are loaded in compression. The plates are made of two material systems, T300/BP907 and IM7/8551-7. Two different lay-ups of T300/BP907 and four different lay-ups of IM7/8551-7 are investigated.The load on the specimen is slowly increased and a series of interferograms are produced during the load cycle. These interferograms are video-recorded. The results obtained from the interferograms and photo-micrographs are substantiated by sectioning studies and ultrasonic C-scanning of some specimens which are unloaded prior to catastrophic failure, but beyond failure initiation. This is made possible by the servo-controlled loading mechanism that regulates the load application and offers the flexibility of unloading a specimen at any given instance in the loadtime history.An underlying objective of the present investigation is the identification of the physics of the failure initiation process. This required testing specimens with different stacking sequences, for a fixed hole diameter, so that consistent trends in the failure process could be identified.It is revealed that the failure is initiated as a localized instability in the 0? plies at the hole surface, approximately at right angles to the loading direction. This instability emanating at the hole edge and propagating into the interior of the specimen within the 0? plies is found to be fiber microbuckling. The microbuckling is found to occur at a local strain level of [...]8600 [mu]strain at the hole edge for the IM material system. This initial failure renders a narrow zone of fibers within the 0? plies to loose structural integrity. Subsequent to the 0?-ply failure, extensive delamination cracking is observed with increasing load. The through thickness location of these delaminations is found to depend on the position of the 0? plies.The delaminated portions spread to the undamaged areas of the laminate by a combination of delamination buckling and growth, the buckling further enhancing the growth. When the delaminated area reaches a critical size, about 75-100% of the hole radius in extent, an accelerated growth rate of the delaminated portions is observed. The culmination of this last event is the complete loss of flexural stiffness of each of the delaminated portions leading to catastrophic failure of the plate. The levels of applied load and the rate at which these events occur depend on the plate stacking sequence.A simple mechanical model is presented for the microbuckling problem. This model addresses the buckling instability of a semi-infinte layered half-plane alternatingly stacked with fibers and matrix, loaded parallel to the surface of the half-plane. The fibers are modelled using Bernoulli-Navier beam theory, and the matrix is assumed to be a linearly elastic foundation. The predicted buckling strains are found to overestimate the experimental result. However, the dependence of the buckling strain on parameters such as the fiber volume fraction, ratio of Youngs moduli of the constituents and Poisson's ratio of the matrix are obtained from the analysis. It is seen that a high fiber volume fraction, increased matrix stiffness, and perfect bonding between fiber and matrix are desirable properties for increasing the compressive strength.
Bone Graft Substitute Provides Metaphyseal Fixation for a Stemless Humeral Implant.
Kim, Myung-Sun; Kovacevic, David; Milks, Ryan A; Jun, Bong-Jae; Rodriguez, Eric; DeLozier, Katherine R; Derwin, Kathleen A; Iannotti, Joseph P
2015-07-01
Stemless humeral fixation has become an alternative to traditional total shoulder arthroplasty, but metaphyseal fixation may be compromised by the quality of the trabecular bone that diminishes with age and disease, and augmentation of the fixation may be desirable. The authors hypothesized that a bone graft substitute (BGS) could achieve initial fixation comparable to polymethylmethacrylate (PMMA) bone cement. Fifteen fresh-frozen human male humerii were randomly implanted using a stemless humeral prosthesis, and metaphyseal fixation was augmented with either high-viscosity PMMA bone cement (PMMA group) or a magnesium-based injectable BGS (OsteoCrete; Bone Solutions Inc, Dallas, Texas) (OC group). Both groups were compared with a control group with no augmentation. Initial stiffness, failure load, failure displacement, failure cycle, and total work were compared among groups. The PMMA and OC groups showed markedly higher failure loads, failure displacements, and failure cycles than the control group (P<.01). There were no statistically significant differences in initial stiffness, failure load, failure displacement, failure cycle, or total work between the PMMA and OC groups. The biomechanical properties of magnesium-based BGS fixation compared favorably with PMMA bone cement in the fixation of stemless humeral prostheses and may provide sufficient initial fixation for this clinical application. Future work will investigate the long-term remodeling characteristics and bone quality at the prosthetic-bone interface in an in vivo model to evaluate the clinical efficacy of this approach. Copyright 2015, SLACK Incorporated.
[Hazard function and life table: an introduction to the failure time analysis].
Matsushita, K; Inaba, H
1987-04-01
Failure time analysis has become popular in demographic studies. It can be viewed as a part of regression analysis with limited dependent variables as well as a special case of event history analysis and multistate demography. The idea of hazard function and failure time analysis, however, has not been properly introduced to nor commonly discussed by demographers in Japan. The concept of hazard function in comparison with life tables is briefly described, where the force of mortality is interchangeable with the hazard rate. The basic idea of failure time analysis is summarized for the cases of exponential distribution, normal distribution, and proportional hazard models. The multiple decrement life table is also introduced as an example of lifetime data analysis with cause-specific hazard rates.
Solder Reflow Failures in Electronic Components During Manual Soldering
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander; Greenwell, Chris; Felt, Frederick
2008-01-01
This viewgraph presentation reviews the solder reflow failures in electronic components that occur during manual soldering. It discusses the specifics of manual-soldering-induced failures in plastic devices with internal solder joints. The failure analysis turned up that molten solder had squeezed up to the die surface along the die molding compound interface, and the dice were not protected with glassivation allowing solder to short gate and source to the drain contact. The failure analysis concluded that the parts failed due to overheating during manual soldering.
Efficient 3-D finite element failure analysis of compression loaded angle-ply plates with holes
NASA Technical Reports Server (NTRS)
Burns, S. W.; Herakovich, C. T.; Williams, J. G.
1987-01-01
Finite element stress analysis and the tensor polynomial failure criterion predict that failure always initiates at the interface between layers on the hole edge for notched angle-ply laminates loaded in compression. The angular location of initial failure is a function of the fiber orientation in the laminate. The dominant stress components initiating failure are shear. It is shown that approximate symmetry can be used to reduce the computer resources required for the case of unaxial loading.
High-throughput sequencing: a failure mode analysis.
Yang, George S; Stott, Jeffery M; Smailus, Duane; Barber, Sarah A; Balasundaram, Miruna; Marra, Marco A; Holt, Robert A
2005-01-04
Basic manufacturing principles are becoming increasingly important in high-throughput sequencing facilities where there is a constant drive to increase quality, increase efficiency, and decrease operating costs. While high-throughput centres report failure rates typically on the order of 10%, the causes of sporadic sequencing failures are seldom analyzed in detail and have not, in the past, been formally reported. Here we report the results of a failure mode analysis of our production sequencing facility based on detailed evaluation of 9,216 ESTs generated from two cDNA libraries. Two categories of failures are described; process-related failures (failures due to equipment or sample handling) and template-related failures (failures that are revealed by close inspection of electropherograms and are likely due to properties of the template DNA sequence itself). Preventative action based on a detailed understanding of failure modes is likely to improve the performance of other production sequencing pipelines.
Application of Interface Technology in Progressive Failure Analysis of Composite Panels
NASA Technical Reports Server (NTRS)
Sleight, D. W.; Lotts, C. G.
2002-01-01
A progressive failure analysis capability using interface technology is presented. The capability has been implemented in the COMET-AR finite element analysis code developed at the NASA Langley Research Center and is demonstrated on composite panels. The composite panels are analyzed for damage initiation and propagation from initial loading to final failure using a progressive failure analysis capability that includes both geometric and material nonlinearities. Progressive failure analyses are performed on conventional models and interface technology models of the composite panels. Analytical results and the computational effort of the analyses are compared for the conventional models and interface technology models. The analytical results predicted with the interface technology models are in good correlation with the analytical results using the conventional models, while significantly reducing the computational effort.
Peek, Giles J; Clemens, Felicity; Elbourne, Diana; Firmin, Richard; Hardy, Pollyanna; Hibbert, Clare; Killer, Hilliary; Mugford, Miranda; Thalanany, Mariamma; Tiruvoipati, Ravin; Truesdale, Ann; Wilson, Andrew
2006-12-23
An estimated 350 adults develop severe, but potentially reversible respiratory failure in the UK annually. Current management uses intermittent positive pressure ventilation, but barotrauma, volutrauma and oxygen toxicity can prevent lung recovery. An alternative treatment, extracorporeal membrane oxygenation, uses cardio-pulmonary bypass technology to temporarily provide gas exchange, allowing ventilator settings to be reduced. While extracorporeal membrane oxygenation is proven to result in improved outcome when compared to conventional ventilation in neonates with severe respiratory failure, there is currently no good evidence from randomised controlled trials to compare these managements for important clinical outcomes in adults, although evidence from case series is promising. The aim of the randomised controlled trial of Conventional ventilatory support vs extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR) is to assess whether, for patients with severe, but potentially reversible, respiratory failure, extracorporeal membrane oxygenation will increase the rate of survival without severe disability ('confined to bed' and 'unable to wash or dress') by six months post-randomisation, and be cost effective from the viewpoints of the NHS and society, compared to conventional ventilatory support. Following assent from a relative, adults (18-65 years) with severe, but potentially reversible, respiratory failure (Murray score >/= 3.0 or hypercapnea with pH < 7.2) will be randomised for consideration of extracorporeal membrane oxygenation at Glenfield Hospital, Leicester or continuing conventional care in a centre providing a high standard of conventional treatment. The central randomisation service will minimise by type of conventional treatment centre, age, duration of high pressure ventilation, hypoxia/hypercapnea, diagnosis and number of organs failed, to ensure balance in key prognostic variables. Extracorporeal membrane oxygenation will not be available for patients meeting entry criteria outside the trial. 180 patients will be recruited to have 80% power to be able to detect a one third reduction in the primary outcome from 65% at 5% level of statistical significance (2-sided test). Secondary outcomes include patient morbidity and health status at 6 months. Analysis will be based on intention to treat. A concurrent economic evaluation will also be performed to compare the costs and outcomes of both treatments.
Shivakoti, Rupak; Yang, Wei-Teng; Gupte, Nikhil; Berendes, Sima; Rosa, Alberto La; Cardoso, Sandra W; Mwelase, Noluthando; Kanyama, Cecilia; Pillay, Sandy; Samaneka, Wadzanai; Riviere, Cynthia; Sugandhavesa, Patcharaphan; Santos, Brento; Poongulali, Selvamuthu; Tripathy, Srikanth; Bollinger, Robert C; Currier, Judith S; Tang, Alice M; Semba, Richard D; Christian, Parul; Campbell, Thomas B; Gupta, Amita
2015-07-01
Anemia is a known risk factor for clinical failure following antiretroviral therapy (ART). Notably, anemia and inflammation are interrelated, and recent studies have associated elevated C-reactive protein (CRP), an inflammation marker, with adverse human immunodeficiency virus (HIV) treatment outcomes, yet their joint effect is not known. The objective of this study was to assess prevalence and risk factors of anemia in HIV infection and to determine whether anemia and elevated CRP jointly predict clinical failure post-ART. A case-cohort study (N = 470 [236 cases, 234 controls]) was nested within a multinational randomized trial of ART efficacy (Prospective Evaluation of Antiretrovirals in Resource Limited Settings [PEARLS]). Cases were incident World Health Organization stage 3, 4, or death by 96 weeks of ART treatment (clinical failure). Multivariable logistic regression was used to determine risk factors for pre-ART (baseline) anemia (females: hemoglobin <12.0 g/dL; males: hemoglobin <13.0 g/dL). Association of anemia as well as concurrent baseline anemia and inflammation (CRP ≥ 10 mg/L) with clinical failure were assessed using multivariable Cox models. Baseline anemia prevalence was 51% with 15% prevalence of concurrent anemia and inflammation. In analysis of clinical failure, multivariate-adjusted hazard ratios were 6.41 (95% confidence interval [CI], 2.82-14.57) for concurrent anemia and inflammation, 0.77 (95% CI, .37-1.58) for anemia without inflammation, and 0.45 (95% CI, .11-1.80) for inflammation without anemia compared to those without anemia and inflammation. ART-naive, HIV-infected individuals with concurrent anemia and inflammation are at particularly high risk of failing treatment, and understanding the pathogenesis could lead to new interventions. Reducing inflammation and anemia will likely improve HIV disease outcomes. Alternatively, concurrent anemia and inflammation could represent individuals with occult opportunistic infections in need of additional screening. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Amato, Roberto; Lim, Pharath; Miotto, Olivo; Amaratunga, Chanaki; Dek, Dalin; Pearson, Richard D.; Almagro-Garcia, Jacob; Neal, Aaron T.; Sreng, Sokunthea; Suon, Seila; Drury, Eleanor; Jyothi, Dushyanth; Stalker, Jim; Kwiatkowski, Dominic P.; Fairhurst, Rick M.
2017-01-01
Summary Background As the prevalence of artemisinin-resistant Plasmodium falciparum malaria increases in the Greater Mekong Subregion (GMS), emerging resistance to partner drugs in artemisinin combination therapies (ACTs) seriously threatens global efforts to treat and eliminate this disease. Molecular markers for ACT failure are urgently needed to monitor the spread of partner drug resistance, and to recommend alternative treatments in Southeast Asia and beyond. Methods We performed a genome-wide association study (GWAS) of 297 P. falciparum isolates from Cambodia to investigate the relationship of 11,630 exonic single-nucleotide polymorphisms (SNPs) and 43 copy number variations (CNVs) with in-vitro piperaquine 50% inhibitory concentrations (IC50s), and tested whether these genetic variants are markers of dihydroartemisinin-piperaquine failures. We then performed a survival analysis of 133 patients to determine whether candidate molecular markers predicted parasite recrudescence following dihydroartemisinin-piperaquine treatment. Findings Piperaquine IC50s increased significantly from 2011 to 2013 in 3 Cambodian provinces. Genome-wide analysis of SNPs identified a chromosome 13 region that associates with elevated piperaquine IC50s. A nonsynonymous SNP (encoding a Glu415Gly substitution) in this region, within a gene encoding an exonuclease, associates with parasite recrudescence following dihydroartemisinin-piperaquine treatment. Genome-wide analysis of CNVs revealed that a single copy of the mdr1 gene on chromosome 5 and a novel amplification of the plasmepsin II and plasmepsin III genes on chromosome 14 also associate with elevated piperaquine IC50s. After adjusting for covariates, both exo-E415G and plasmepsin II-III markers significantly associate with decreased treatment efficacy (0.38 and 0.41 survival rates, respectively). Interpretation The exo-E415G SNP and plasmepsin II-III amplification are markers of piperaquine resistance and dihydroartemisinin-piperaquine failures in Cambodia, and can help monitor the spread of these phenotypes into GMS countries, and elucidate the mechanism of piperaquine resistance. Since plasmepsins are involved in the parasite’s haemoglobin-to-haemozoin conversion pathway, targeted by related antimalarials, plasmepsin II-III amplification likely mediates piperaquine resistance. Funding Intramural Research Program of the US National Institute of Allergy and Infectious Diseases, National Institutes of Health; Wellcome Trust; Bill and Melinda Gates Foundation; Medical Research Council; and UK Department for International Development. PMID:27818095
Fatigue of notched fiber composite laminates. Part 1: Analytical model
NASA Technical Reports Server (NTRS)
Mclaughlin, P. V., Jr.; Kulkarni, S. V.; Huang, S. N.; Rosen, B. W.
1975-01-01
A description is given of a semi-empirical, deterministic analysis for prediction and correlation of fatigue crack growth, residual strength, and fatigue lifetime for fiber composite laminates containing notches (holes). The failure model used for the analysis is based upon composite heterogeneous behavior and experimentally observed failure modes under both static and fatigue loading. The analysis is consistent with the wearout philosophy. Axial cracking and transverse cracking failure modes are treated together in the analysis. Cracking off-axis is handled by making a modification to the axial cracking analysis. The analysis predicts notched laminate failure from unidirectional material fatique properties using constant strain laminate analysis techniques. For multidirectional laminates, it is necessary to know lamina fatique behavior under axial normal stress, transverse normal stress and axial shear stress. Examples of the analysis method are given.
Rodríguez, Alejandro; Ferri, Cristina; Martin-Loeches, Ignacio; Díaz, Emili; Masclans, Joan R; Gordo, Federico; Sole-Violán, Jordi; Bodí, María; Avilés-Jurado, Francesc X; Trefler, Sandra; Magret, Monica; Moreno, Gerard; Reyes, Luis F; Marin-Corral, Judith; Yebenes, Juan C; Esteban, Andres; Anzueto, Antonio; Aliberti, Stefano; Restrepo, Marcos I
2017-10-01
Despite wide use of noninvasive ventilation (NIV) in several clinical settings, the beneficial effects of NIV in patients with hypoxemic acute respiratory failure (ARF) due to influenza infection remain controversial. The aim of this study was to identify the profile of patients with risk factors for NIV failure using chi-square automatic interaction detection (CHAID) analysis and to determine whether NIV failure is associated with ICU mortality. This work was a secondary analysis from prospective and observational multi-center analysis in critically ill subjects admitted to the ICU with ARF due to influenza infection requiring mechanical ventilation. Three groups of subjects were compared: (1) subjects who received NIV immediately after ICU admission for ARF and then failed (NIV failure group); (2) subjects who received NIV immediately after ICU admission for ARF and then succeeded (NIV success group); and (3) subjects who received invasive mechanical ventilation immediately after ICU admission for ARF (invasive mechanical ventilation group). Profiles of subjects with risk factors for NIV failure were obtained using CHAID analysis. Of 1,898 subjects, 806 underwent NIV, and 56.8% of them failed. Acute Physiology and Chronic Health Evaluation II (APACHE II) score, Sequential Organ Failure Assessment (SOFA) score, infiltrates in chest radiograph, and ICU mortality (38.4% vs 6.3%) were higher ( P < .001) in the NIV failure than in the NIV success group. SOFA score was the variable most associated with NIV failure, and 2 cutoffs were determined. Subjects with SOFA ≥ 5 had a higher risk of NIV failure (odds ratio = 3.3, 95% CI 2.4-4.5). ICU mortality was higher in subjects with NIV failure (38.4%) compared with invasive mechanical ventilation subjects (31.3%, P = .018), and NIV failure was associated with increased ICU mortality (odds ratio = 11.4, 95% CI 6.5-20.1). An automatic and non-subjective algorithm based on CHAID decision-tree analysis can help to define the profile of patients with different risks of NIV failure, which might be a promising tool to assist in clinical decision making to avoid the possible complications associated with NIV failure. Copyright © 2017 by Daedalus Enterprises.
Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C., III
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Vianello, Andrea; Arcaro, Giovanna; Paladini, Luciana; Iovino, Silvia
2016-08-01
Patients with Idiopathic Pulmonary Fibrosis (IPF) requiring Invasive Mechanical Ventilation (IMV) following unsuccessful treatment with Non-Invasive Ventilation (NIV) have a high mortality rate. IMV is, moreover, an independent predictor of poor outcome during the post-transplantation period in patients on waiting lists for Lung Transplantation (LT). Here we describe the successful management of an IPF patient with acute respiratory failure (ARF) using a pump-assisted veno-venous system for extracorporeal CO2 removal (ECCO2R) (ProLUNG® system) as an alternative to endotracheal intubation (ETI) following NIV failure. Given this positive experience, further studies are warranted focusing on the ECCO2R system's tolerability, safety, and efficacy in patients with IPF and severe ARF in whom NIV alone is ineffective.
Self-esteem and counterfactual thinking.
Roese, N J; Olson, J M
1993-07-01
Two studies examined the relation between self-esteem and counterfactual thinking (consideration of "might-have-been" alternatives to reality). Ss imagined themselves in scenarios with another actor that resulted in either success or failure. Ss then "undid" the outcome by altering events that preceded the outcome. Following success, high self-esteem (HSE) Ss were more likely than low self-esteem (LSE) Ss to mutate their own actions. Following failure, LSE Ss were more likely than HSE Ss to mutate their own actions. Also, the structure of counterfactuals was influenced by outcome valence but not by self-esteem: Subtractive structures (in which antecedents are removed) were elicited by success, whereas additive structures (in which antecedents are added) were elicited by failure. The importance of the self and individual differences in self-esteem to counterfactual thinking is discussed.
The effects of heart failure on renal function.
Udani, Suneel M; Koyner, Jay L
2010-08-01
Heart-kidney interactions have been increasingly recognized by clinicians and researchers who study and treat heart failure and kidney disease. A classification system has been developed to categorize the different manifestations of cardiac and renal dysfunction. Work has highlighted the significant negative prognostic effect of worsening renal function on outcomes for individuals with heart failure. The etiology of concomitant cardiac and renal dysfunction remains unclear; however, evidence supports alternatives to the established theory of underfilling, including effects of venous congestion and changes in intra-abdominal pressure. Conventional therapy focuses on blockade of the renin-angiotensin-aldosterone system with expanding use of direct renin and aldosterone antagonists. Novel therapeutic interventions using extracorporeal therapy and antagonists of the adenosine pathway show promise and require further investigation. 2010 Elsevier Inc. All rights reserved.
The Effects of Heart Failure on Renal Function
Udani, Suneel M; Koyner, Jay L
2010-01-01
Summary Heart-kidney interactions have been increasingly recognized by clinicians and researchers involved in the study and treatment of heart failure and kidney disease. A classification system has been developed to categorize the different manifestations of cardiac and renal dysfunction. Recent work has highlighted the significant negative prognostic effect of worsening renal function on outcomes for individuals with heart failure. The etiology of the concomitant cardiac and renal dysfunction remains unclear; however, increasing evidence supports alternatives to the established theory of underfilling, including effects of venous congestion and changes in intra-abdominal pressure. Conventional therapy focuses on blockade of the renin-angiotensin-aldosterone system with expanding use of direct renin and aldosterone antagonists. Novel therapeutic interventions using extracorporeal therapy and antagonists of the adenosine pathway show promise and require further investigation. PMID:20621250
Gyro and accelerometer failure detection and identification in redundant sensor systems
NASA Technical Reports Server (NTRS)
Potter, J. E.; Deckert, J. C.
1972-01-01
Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.
Survival analysis and classification methods for forest fire size
2018-01-01
Factors affecting wildland-fire size distribution include weather, fuels, and fire suppression activities. We present a novel application of survival analysis to quantify the effects of these factors on a sample of sizes of lightning-caused fires from Alberta, Canada. Two events were observed for each fire: the size at initial assessment (by the first fire fighters to arrive at the scene) and the size at “being held” (a state when no further increase in size is expected). We developed a statistical classifier to try to predict cases where there will be a growth in fire size (i.e., the size at “being held” exceeds the size at initial assessment). Logistic regression was preferred over two alternative classifiers, with covariates consistent with similar past analyses. We conducted survival analysis on the group of fires exhibiting a size increase. A screening process selected three covariates: an index of fire weather at the day the fire started, the fuel type burning at initial assessment, and a factor for the type and capabilities of the method of initial attack. The Cox proportional hazards model performed better than three accelerated failure time alternatives. Both fire weather and fuel type were highly significant, with effects consistent with known fire behaviour. The effects of initial attack method were not statistically significant, but did suggest a reverse causality that could arise if fire management agencies were to dispatch resources based on a-priori assessment of fire growth potentials. We discuss how a more sophisticated analysis of larger data sets could produce unbiased estimates of fire suppression effect under such circumstances. PMID:29320497
Survival analysis and classification methods for forest fire size.
Tremblay, Pier-Olivier; Duchesne, Thierry; Cumming, Steven G
2018-01-01
Factors affecting wildland-fire size distribution include weather, fuels, and fire suppression activities. We present a novel application of survival analysis to quantify the effects of these factors on a sample of sizes of lightning-caused fires from Alberta, Canada. Two events were observed for each fire: the size at initial assessment (by the first fire fighters to arrive at the scene) and the size at "being held" (a state when no further increase in size is expected). We developed a statistical classifier to try to predict cases where there will be a growth in fire size (i.e., the size at "being held" exceeds the size at initial assessment). Logistic regression was preferred over two alternative classifiers, with covariates consistent with similar past analyses. We conducted survival analysis on the group of fires exhibiting a size increase. A screening process selected three covariates: an index of fire weather at the day the fire started, the fuel type burning at initial assessment, and a factor for the type and capabilities of the method of initial attack. The Cox proportional hazards model performed better than three accelerated failure time alternatives. Both fire weather and fuel type were highly significant, with effects consistent with known fire behaviour. The effects of initial attack method were not statistically significant, but did suggest a reverse causality that could arise if fire management agencies were to dispatch resources based on a-priori assessment of fire growth potentials. We discuss how a more sophisticated analysis of larger data sets could produce unbiased estimates of fire suppression effect under such circumstances.
Probabilistic analysis on the failure of reactivity control for the PWR
NASA Astrophysics Data System (ADS)
Sony Tjahyani, D. T.; Deswandri; Sunaryo, G. R.
2018-02-01
The fundamental safety function of the power reactor is to control reactivity, to remove heat from the reactor, and to confine radioactive material. The safety analysis is used to ensure that each parameter is fulfilled during the design and is done by deterministic and probabilistic method. The analysis of reactivity control is important to be done because it will affect the other of fundamental safety functions. The purpose of this research is to determine the failure probability of the reactivity control and its failure contribution on a PWR design. The analysis is carried out by determining intermediate events, which cause the failure of reactivity control. Furthermore, the basic event is determined by deductive method using the fault tree analysis. The AP1000 is used as the object of research. The probability data of component failure or human error, which is used in the analysis, is collected from IAEA, Westinghouse, NRC and other published documents. The results show that there are six intermediate events, which can cause the failure of the reactivity control. These intermediate events are uncontrolled rod bank withdrawal at low power or full power, malfunction of boron dilution, misalignment of control rod withdrawal, malfunction of improper position of fuel assembly and ejection of control rod. The failure probability of reactivity control is 1.49E-03 per year. The causes of failures which are affected by human factor are boron dilution, misalignment of control rod withdrawal and malfunction of improper position for fuel assembly. Based on the assessment, it is concluded that the failure probability of reactivity control on the PWR is still within the IAEA criteria.
Development of STS/Centaur failure probabilities liftoff to Centaur separation
NASA Technical Reports Server (NTRS)
Hudson, J. M.
1982-01-01
The results of an analysis to determine STS/Centaur catastrophic vehicle response probabilities for the phases of vehicle flight from STS liftoff to Centaur separation from the Orbiter are presented. The analysis considers only category one component failure modes as contributors to the vehicle response mode probabilities. The relevant component failure modes are grouped into one of fourteen categories of potential vehicle behavior. By assigning failure rates to each component, for each of its failure modes, the STS/Centaur vehicle response probabilities in each phase of flight can be calculated. The results of this study will be used in a DOE analysis to ascertain the hazard from carrying a nuclear payload on the STS.
Mato, A R; Hill, B T; Lamanna, N; Barr, P M; Ujjani, C S; Brander, D M; Howlett, C; Skarbnik, A P; Cheson, B D; Zent, C S; Pu, J J; Kiselev, P; Foon, K; Lenhart, J; Henick Bachow, S; Winter, A M; Cruz, A-L; Claxton, D F; Goy, A; Daniel, C; Isaac, K; Kennard, K H; Timlin, C; Fanning, M; Gashonia, L; Yacur, M; Svoboda, J; Schuster, S J; Nabhan, C
2017-05-01
Ibrutinib, idelalisib, and venetoclax are approved for treating CLL patients in the United States. However, there is no guidance as to their optimal sequence. We conducted a multicenter, retrospective analysis of CLL patients treated with kinase inhibitors (KIs) or venetoclax. We examined demographics, discontinuation reasons, overall response rates (ORR), survival, and post-KI salvage strategies. Primary endpoint was progression-free survival (PFS). A total of 683 patients were identified. Baseline characteristics were similar in the ibrutinib and idelalisib groups. ORR to ibrutinib and idelalisib as first KI was 69% and 81%, respectively. With a median follow-up of 17 months (range 1-60), median PFS and OS for the entire cohort were 35 months and not reached. Patients treated with ibrutinib (versus idelalisib) as first KI had a significantly better PFS in all settings; front-line [hazard ratios (HR) 2.8, CI 1.3-6.3, P = 0.01], relapsed-refractory (HR 2.8, CI 1.9-4.1, P < 0.001), del17p (HR 2.0, CI 1.2-3.4, P = 0.008), and complex karyotype (HR 2.5, CI 1.2-5.2, P = 0.02). At the time of initial KI failure, use of an alternate KI or venetoclax had a superior PFS when compared with chemoimmunotherapy. Furthermore, patients who discontinued ibrutinib due to progression or toxicity had marginally improved outcomes if they received venetoclax (ORR 79%) versus idelalisib (ORR 46%) (PFS HR .6, CI.3-1.0, P = 0.06). In the largest real-world experience of novel agents in CLL, ibrutinib appears superior to idelalisib as first KI. Furthermore, in the setting of KI failure, alternate KI or venetoclax therapy appear superior to chemoimmunotherapy combinations. The use of venetoclax upon ibrutinib failure might be superior to idelalisib. These data support the need for trials testing sequencing strategies to optimize treatment algorithms. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Cycles till failure of silver-zinc cells with completing failures modes: Preliminary data analysis
NASA Technical Reports Server (NTRS)
Sidik, S. M.; Leibecki, H. F.; Bozek, J. M.
1980-01-01
One hundred and twenty nine cells were run through charge-discharge cycles until failure. The experiment design was a variant of a central composite factorial in five factors. Preliminary data analysis consisted of response surface estimation of life. Batteries fail under two basic modes; a low voltage condition and an internal shorting condition. A competing failure modes analysis using maximum likelihood estimation for the extreme value life distribution was performed. Extensive diagnostics such as residual plotting and probability plotting were employed to verify data quality and choice of model.
Failure Modes and Effects Analysis (FMEA): A Bibliography
NASA Technical Reports Server (NTRS)
2000-01-01
Failure modes and effects analysis (FMEA) is a bottom-up analytical process that identifies process hazards, which helps managers understand vulnerabilities of systems, as well as assess and mitigate risk. It is one of several engineering tools and techniques available to program and project managers aimed at increasing the likelihood of safe and successful NASA programs and missions. This bibliography references 465 documents in the NASA STI Database that contain the major concepts, failure modes or failure analysis, in either the basic index of the major subject terms.
Analysis of Discrete-Source Damage Progression in a Tensile Stiffened Composite Panel
NASA Technical Reports Server (NTRS)
Wang, John T.; Lotts, Christine G.; Sleight, David W.
1999-01-01
This paper demonstrates the progressive failure analysis capability in NASA Langley s COMET-AR finite element analysis code on a large-scale built-up composite structure. A large-scale five stringer composite panel with a 7-in. long discrete source damage was analyzed from initial loading to final failure including the geometric and material nonlinearities. Predictions using different mesh sizes, different saw cut modeling approaches, and different failure criteria were performed and assessed. All failure predictions have a reasonably good correlation with the test result.
Failure modes and effects analysis automation
NASA Technical Reports Server (NTRS)
Kamhieh, Cynthia H.; Cutts, Dannie E.; Purves, R. Byron
1988-01-01
A failure modes and effects analysis (FMEA) assistant was implemented as a knowledge based system and will be used during design of the Space Station to aid engineers in performing the complex task of tracking failures throughout the entire design effort. The three major directions in which automation was pursued were the clerical components of the FMEA process, the knowledge acquisition aspects of FMEA, and the failure propagation/analysis portions of the FMEA task. The system is accessible to design, safety, and reliability engineers at single user workstations and, although not designed to replace conventional FMEA, it is expected to decrease by many man years the time required to perform the analysis.
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
46 CFR 62.30-5 - Independence.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Reliability and Safety Criteria, All Automated Vital Systems § 62.30-5 Independence. (a) Single non-concurrent failures in control, alarm, or instrumentation systems, and their logical consequences, must not prevent...)(2) and (b)(3) of this section, primary control, alternate control, safety control, and alarm and...
RNA splicing regulated by RBFOX1 is essential for cardiac function in zebrafish.
Frese, Karen S; Meder, Benjamin; Keller, Andreas; Just, Steffen; Haas, Jan; Vogel, Britta; Fischer, Simon; Backes, Christina; Matzas, Mark; Köhler, Doreen; Benes, Vladimir; Katus, Hugo A; Rottbauer, Wolfgang
2015-08-15
Alternative splicing is one of the major mechanisms through which the proteomic and functional diversity of eukaryotes is achieved. However, the complex nature of the splicing machinery, its associated splicing regulators and the functional implications of alternatively spliced transcripts are only poorly understood. Here, we investigated the functional role of the splicing regulator rbfox1 in vivo using the zebrafish as a model system. We found that loss of rbfox1 led to progressive cardiac contractile dysfunction and heart failure. By using deep-transcriptome sequencing and quantitative real-time PCR, we show that depletion of rbfox1 in zebrafish results in an altered isoform expression of several crucial target genes, such as actn3a and hug. This study underlines that tightly regulated splicing is necessary for unconstrained cardiac function and renders the splicing regulator rbfox1 an interesting target for investigation in human heart failure and cardiomyopathy. © 2015. Published by The Company of Biologists Ltd.
Neural networks: Alternatives to conventional techniques for automatic docking
NASA Technical Reports Server (NTRS)
Vinz, Bradley L.
1994-01-01
Automatic docking of orbiting spacecraft is a crucial operation involving the identification of vehicle orientation as well as complex approach dynamics. The chaser spacecraft must be able to recognize the target spacecraft within a scene and achieve accurate closing maneuvers. In a video-based system, a target scene must be captured and transformed into a pattern of pixels. Successful recognition lies in the interpretation of this pattern. Due to their powerful pattern recognition capabilities, artificial neural networks offer a potential role in interpretation and automatic docking processes. Neural networks can reduce the computational time required by existing image processing and control software. In addition, neural networks are capable of recognizing and adapting to changes in their dynamic environment, enabling enhanced performance, redundancy, and fault tolerance. Most neural networks are robust to failure, capable of continued operation with a slight degradation in performance after minor failures. This paper discusses the particular automatic docking tasks neural networks can perform as viable alternatives to conventional techniques.
van Hal, Sebastiaan J.; Fowler, Vance G.
2013-01-01
For more than 4 decades, vancomycin has been the antibiotic of choice for methicillin-resistant Staphylococcus aureus (MRSA) infections. Recently, infections due to isolates with high but susceptible vancomycin minimum inhibitory concentrations have been associated with additional treatment failures and patient mortality. These poorer outcomes may in part be explained by the inability of attaining appropriate vancomycin levels in these patients. However, assumptions that these poor outcomes are solely due to failure to achieve optimal serum levels of vancomycin are premature. The availability of effective alternatives further erodes the position of vancomycin as first-line therapy. The emergence of resistance and cost considerations, however, favor a more measured approach when using alternative antimicrobials. Collectively, the current available data suggest that the optimal therapy for MRSA infections remains unclear. In the absence of further data, the Infectious Diseases Society of America guidelines remain relevant and inform clinicians of best practice for treating patients with MRSA infections. PMID:23511300
Modern methodology of designing target reliability into rotating mechanical components
NASA Technical Reports Server (NTRS)
Kececioglu, D. B.; Chester, L. B.
1973-01-01
Experimentally determined distributional cycles-to-failure versus maximum alternating nominal strength (S-N) diagrams, and distributional mean nominal strength versus maximum alternating nominal strength (Goodman) diagrams are presented. These distributional S-N and Goodman diagrams are for AISI 4340 steel, R sub c 35/40 hardness, round, cylindrical specimens 0.735 in. in diameter and 6 in. long with a circumferential groove 0.145 in. radius for a theoretical stress concentration = 1.42 and 0.034 in. radius for a stress concentration = 2.34. The specimens are subjected to reversed bending and steady torque in specially built, three complex-fatigue research machines. Based on these results, the effects on the distributional S-N and Goodman diagrams and on service life of superimposing steady torque on reversed bending are established, as well as the effect of various stress concentrations. In addition a computer program for determining the three-parameter Weibull distribution representing the cycles-to-failure data, and two methods for calculating the reliability of components subjected to cumulative fatigue loads are given.
De Vecchis, R; Esposito, C; Ariano, C
2014-04-01
Intravenous diuretics at relatively high doses are currently used for treating acute decompensated heart failure (ADHF). However, the existence of harmful side effects diuretic-related, such as electrolyte abnormalities, symptomatic hypotension and marked neuro-hormonal activation have led researchers to implement alternative therapeutic tools such as isolated ultrafiltration (IUF). Our study aimed to compare intravenous diuretics vs. IUF as regards their respective efficacy and safety in ADHF patients through systematic review and meta-analysis of data derived from relevant randomized controlled trials. 6 studies grouping a total of 477 patients were included in the systematic review. By contrast, data from only three studies were pooled for the meta-analysis, because of different adopted outcomes or marked dissimilarities in the data presentation . Weight loss at 48 h was greater in IUF group compared to the diuretics group [weighted mean difference (WMD)=1.77 kg; 95%CI: 1.18-2.36 kg; P<0.001)]. Similarly, greater fluid loss at 48 h was found in IUF group in comparison with diuretics group (WMD=1.2 liters; 95%CI: 0.73-1.67 liters; P< 0.001). In contrast, the probability of exhibiting worsening renal function (WRF), i.e., increase in serum creatinine > 0.3 mg/dl at 48 hours, was similar to the one found in the diuretics group (OR=1.33; 95% CI: 0.81-2.16 P=0.26). On the basis of this meta-analysis, IUF induced greater weight loss and larger fluid removal compared to iv diuretics in ADHF patients, whereas the probability of developing WRF was not significantly different in the comparison between iv diuretics and IUF.
NASA Astrophysics Data System (ADS)
Faruk, Alfensi
2018-03-01
Survival analysis is a branch of statistics, which is focussed on the analysis of time- to-event data. In multivariate survival analysis, the proportional hazards (PH) is the most popular model in order to analyze the effects of several covariates on the survival time. However, the assumption of constant hazards in PH model is not always satisfied by the data. The violation of the PH assumption leads to the misinterpretation of the estimation results and decreasing the power of the related statistical tests. On the other hand, the accelerated failure time (AFT) models do not assume the constant hazards in the survival data as in PH model. The AFT models, moreover, can be used as the alternative to PH model if the constant hazards assumption is violated. The objective of this research was to compare the performance of PH model and the AFT models in analyzing the significant factors affecting the first birth interval (FBI) data in Indonesia. In this work, the discussion was limited to three AFT models which were based on Weibull, exponential, and log-normal distribution. The analysis by using graphical approach and a statistical test showed that the non-proportional hazards exist in the FBI data set. Based on the Akaike information criterion (AIC), the log-normal AFT model was the most appropriate model among the other considered models. Results of the best fitted model (log-normal AFT model) showed that the covariates such as women’s educational level, husband’s educational level, contraceptive knowledge, access to mass media, wealth index, and employment status were among factors affecting the FBI in Indonesia.
NASA Technical Reports Server (NTRS)
Schmeckpeper, K. R.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 1671 failure modes analyzed, 9 single failures were determined to result in loss of crew or vehicle. Three single failures unique to intact abort were determined to result in possible loss of the crew or vehicle. A possible loss of mission could result if any of 136 single failures occurred. Six of the criticality 1/1 failures are in two rotary and two pushbutton switches that control External Tank and Solid Rocket Booster separation. The other 6 criticality 1/1 failures are fuses, one each per Aft Power Control Assembly (APCA) 4, 5, and 6 and one each per Forward Power Control Assembly (FPCA) 1, 2, and 3, that supply power to certain Main Propulsion System (MPS) valves and Forward Reaction Control System (RCS) circuits.
Development of automotive battery systems capable of surviving modern underhood environments
NASA Astrophysics Data System (ADS)
Pierson, John R.; Johnson, Richard T.
The starting, lighting, and ignition (SLI) battery in today's automobile typically finds itself in an engine compartment that is jammed with mechanical, electrical, and electronic devices. The spacing of these devices precludes air movement and, thus, heat transfer out of the compartment. Furthermore, many of the devices, in addition to the internal combustion engine, actually generate heat. The resulting underhood environment is extremely hostile to thermally-sensitive components, especially the battery. All indications point to a continuation of this trend towards higher engine-compartment temperatures as future vehicles evolve. The impact of ambient temperature on battery life is clearly demonstrated in the failure-mode analysis conducted by the Battery Council International in 1990. This study, when combined with additional failure-mode analyses, vehicle systems simulation, and elevated temperature life testing, provides insight into the potential for extension of life of batteries. Controlled fleet and field tests are used to document and quantify improvements in product design. Three approaches to battery life extension under adverse thermal conditions are assessed, namely: (i) battery design; (ii) thermal management, and (iii) alternative battery locations. The advantages and disadvantages of these approaches (both individually and in combination) for original equipment and aftermarket applications are explored.
Risk-based planning analysis for a single levee
NASA Astrophysics Data System (ADS)
Hui, Rui; Jachens, Elizabeth; Lund, Jay
2016-04-01
Traditional risk-based analysis for levee planning focuses primarily on overtopping failure. Although many levees fail before overtopping, few planning studies explicitly include intermediate geotechnical failures in flood risk analysis. This study develops a risk-based model for two simplified levee failure modes: overtopping failure and overall intermediate geotechnical failure from through-seepage, determined by the levee cross section represented by levee height and crown width. Overtopping failure is based only on water level and levee height, while through-seepage failure depends on many geotechnical factors as well, mathematically represented here as a function of levee crown width using levee fragility curves developed from professional judgment or analysis. These levee planning decisions are optimized to minimize the annual expected total cost, which sums expected (residual) annual flood damage and annualized construction costs. Applicability of this optimization approach to planning new levees or upgrading existing levees is demonstrated preliminarily for a levee on a small river protecting agricultural land, and a major levee on a large river protecting a more valuable urban area. Optimized results show higher likelihood of intermediate geotechnical failure than overtopping failure. The effects of uncertainty in levee fragility curves, economic damage potential, construction costs, and hydrology (changing climate) are explored. Optimal levee crown width is more sensitive to these uncertainties than height, while the derived general principles and guidelines for risk-based optimal levee planning remain the same.
Finite Element Creep-Fatigue Analysis of a Welded Furnace Roll for Identifying Failure Root Cause
NASA Astrophysics Data System (ADS)
Yang, Y. P.; Mohr, W. C.
2015-11-01
Creep-fatigue induced failures are often observed in engineering components operating under high temperature and cyclic loading. Understanding the creep-fatigue damage process and identifying failure root cause are very important for preventing such failures and improving the lifetime of engineering components. Finite element analyses including a heat transfer analysis and a creep-fatigue analysis were conducted to model the cyclic thermal and mechanical process of a furnace roll in a continuous hot-dip coating line. Typically, the roll has a short life, <1 year, which has been a problem for a long time. The failure occurred in the weld joining an end bell to a roll shell and resulted in the complete 360° separation of the end bell from the roll shell. The heat transfer analysis was conducted to predict the temperature history of the roll by modeling heat convection from hot air inside the furnace. The creep-fatigue analysis was performed by inputting the predicted temperature history and applying mechanical loads. The analysis results showed that the failure was resulted from a creep-fatigue mechanism rather than a creep mechanism. The difference of material properties between the filler metal and the base metal is the root cause for the roll failure, which induces higher creep strain and stress in the interface between the weld and the HAZ.
Finite element analysis of the failure mechanism of gentle slopes in weak disturbed clays
NASA Astrophysics Data System (ADS)
Lollino, Piernicola; Mezzina, Giuseppe; Cotecchia, Federica
2014-05-01
Italian south-eastern Apennines are affected by a large number of deep slow active landslide processes that interact with urban structures and infrastructures throughout the region, thus causing damages and economic losses. For most landslide processes in the region, the main predisposing factors for instability are represented by the piezometric regime and the extremely poor mechanical properties of the weak disturbed clays in the lower and central portions of the slopes that are overlaid in some cases by a stiffer cap layer, formed of rocky flysch, e.g. alternations of rock and soil strata. Based on phenomenological approaches, landslide processes are deemed to be triggered within the weaker clay layer and later on to develop upward to the stiffer cap, with the shear bands reaching also high depths. The paper presents the results of two-dimensional numerical analyses of the failure mechanisms developing in the unstable slopes of the region, carried out by means of the finite element method (Plaxis 2011) applied to slope conditions representative for the region. In particular, the effects of slope inclination, along with the thickness and the strength of the material forming the caprock at the top of the slope, on the depth of the sliding surface, the mobilised strengths, the evolution of the landslide process and the predisposing factors of landsliding have been explored by means of the finite element analysis of an ideal case study representative of the typical geomechanical context of the region. In particular, the increase of slope inclination is shown to raise the depth of the shear band as well as to extend landslide scarp upwards, in accordance with the field evidence. Moreover, the numerical results indicate how the increase of the caprock thickness tends to confine the development of the shear band to the underlying weaker clay layer, so that the depth of the shear band is also observed to reduce, and when the stiffer top stratum becomes involved in the retrogression of the failure process. The numerical results allow also for the investigation of the variation in seepage conditions that combine with the variations in litostratigraphy in determining the variations of the features of the failure mechanism.
Electromigration analysis of solder joints under ac load: A mean time to failure model
NASA Astrophysics Data System (ADS)
Yao, Wei; Basaran, Cemal
2012-03-01
In this study, alternating current (ac) electromigration (EM) degradation simulations were carried out for Sn95.5%Ag4.0%Cu0.5 (SAC405- by weight) solder joints. Mass transport analysis was conducted with viscoplastic material properties for quantifying damage mechanism in solder joints. Square, sine, and triangle current wave forms ac were used as input signals. dc and pulsed dc (PDC) electromigration analysis were conducted for comparison purposes. The maximum current density ranged from 2.2×106A/cm2 to 5.0×106A/cm2, frequency ranged from 0.05 Hz to 5 Hz with ambient temperature varying from 350 K to 450 K. Because the room temperature is nearly two-thirds of SAC solder joint's melting point on absolute temperature scale (494.15 K), viscoplastic material model is essential. Entropy based damage evolution model was used to investigate mean time to failure (MTF) behavior of solder joints subjected to ac stressing. It was observed that MTF was inversely proportional to ambient temperature T1.1 in Celsius and also inversely proportional to current density j0.27 in A/cm2. Higher frequency will lead to a shorter lifetime with in the frequency range we studied, and a relationship is proposed as MTF∝f-0.41. Lifetime of a solder joint subjected to ac is longer compared with dc and PDC loading conditions. By introducing frequency, ambient temperature and current density dependency terms, a modified MTTF equation was proposed for solder joints subjected to ac current stressing.
Independent Orbiter Assessment (IOA): Analysis of the communication and tracking subsystem
NASA Technical Reports Server (NTRS)
Gardner, J. R.; Robinson, W. M.; Trahan, W. H.; Daley, E. S.; Long, W. C.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Communication and Tracking hardware. The IOA analysis process utilized available Communication and Tracking hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Patel, Dipen A; Michel, Andre; Stephens, Jennifer; Weber, Bertram; Petrik, Christian; Charbonneau, Claudie
2014-01-01
Across Europe, methicillin-resistant Staphylococcus aureus (MRSA) is considered to be the primary cause of nosocomial pneumonia (NP). In Germany alone, approximately 14,000 cases of MRSA-associated NP occur annually, which may have a significant impact on health care resource use and associated economic costs. The objective of this study was to investigate the economic impact of linezolid compared with that of vancomycin in the treatment of hospitalized patients with MRSA-confirmed NP in the German health care system. A 4-week decision tree model incorporated published data and expert opinion on clinical parameters, resource use, and costs (2012 euros) was constructed. The base case first-line treatment duration for patients with MRSA-confirmed NP was 10 days. Treatment success (survival), failure due to lack of efficacy, serious adverse events, and mortality were possible outcomes that could impact costs. Alternate scenarios were analyzed, such as varying treatment duration (7 or 14 days) or treatment switch due to a serious adverse event/treatment failure (at day 5 or 10). The model calculated total base case inpatient costs of €15,116 for linezolid and €15,239 for vancomycin. The incremental cost-effectiveness ratio favored linezolid (versus vancomycin), with marginally lower costs (by €123) and greater efficacy (+2.7% absolute difference in the proportion of patients successfully treated for MRSA NP). Approximately 85%-87% of the total treatment costs were attributed to hospital stay (primarily in the intensive care unit). Sensitivity analysis yielded similar results. The model results show that linezolid is a cost-effective alternative to vancomycin for MRSA-confirmed NP, largely attributable to the higher clinical response rate of patients treated with linezolid.
Nouri.Gharahasanlou, Ali; Mokhtarei, Ashkan; Khodayarei, Aliasqar; Ataei, Mohammad
2014-01-01
Evaluating and analyzing the risk in the mining industry is a new approach for improving the machinery performance. Reliability, safety, and maintenance management based on the risk analysis can enhance the overall availability and utilization of the mining technological systems. This study investigates the failure occurrence probability of the crushing and mixing bed hall department at Azarabadegan Khoy cement plant by using fault tree analysis (FTA) method. The results of the analysis in 200 h operating interval show that the probability of failure occurrence for crushing, conveyor systems, crushing and mixing bed hall department is 73, 64, and 95 percent respectively and the conveyor belt subsystem found as the most probable system for failure. Finally, maintenance as a method of control and prevent the occurrence of failure is proposed. PMID:26779433
Stress Analysis of B-52B and B-52H Air-Launching Systems Failure-Critical Structural Components
NASA Technical Reports Server (NTRS)
Ko, William L.
2005-01-01
The operational life analysis of any airborne failure-critical structural component requires the stress-load equation, which relates the applied load to the maximum tangential tensile stress at the critical stress point. The failure-critical structural components identified are the B-52B Pegasus pylon adapter shackles, B-52B Pegasus pylon hooks, B-52H airplane pylon hooks, B-52H airplane front fittings, B-52H airplane rear pylon fitting, and the B-52H airplane pylon lower sway brace. Finite-element stress analysis was performed on the said structural components, and the critical stress point was located and the stress-load equation was established for each failure-critical structural component. The ultimate load, yield load, and proof load needed for operational life analysis were established for each failure-critical structural component.
Nouri Gharahasanlou, Ali; Mokhtarei, Ashkan; Khodayarei, Aliasqar; Ataei, Mohammad
2014-04-01
Evaluating and analyzing the risk in the mining industry is a new approach for improving the machinery performance. Reliability, safety, and maintenance management based on the risk analysis can enhance the overall availability and utilization of the mining technological systems. This study investigates the failure occurrence probability of the crushing and mixing bed hall department at Azarabadegan Khoy cement plant by using fault tree analysis (FTA) method. The results of the analysis in 200 h operating interval show that the probability of failure occurrence for crushing, conveyor systems, crushing and mixing bed hall department is 73, 64, and 95 percent respectively and the conveyor belt subsystem found as the most probable system for failure. Finally, maintenance as a method of control and prevent the occurrence of failure is proposed.
Availability Estimate of a Conceptual ESM System.
1979-06-01
affect mission operation.t A functional block level failure modes and effects analysis ( FMEA ) performed on the filter resulted in an assessed failure rate...is based on an FMEA of failures that disable the function (see Appendix A). A further 29 examination of the filter piece-parts reveals that the driver...Digital-to-analog converter DC Direct current DF Direction finding ESM Electronic Support Measures FMEA Failure modes and effects analysis FMPO
Failure environment analysis tool applications
NASA Astrophysics Data System (ADS)
Pack, Ginger L.; Wadsworth, David B.
1993-02-01
Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.
Failure environment analysis tool applications
NASA Technical Reports Server (NTRS)
Pack, Ginger L.; Wadsworth, David B.
1993-01-01
Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.
Failure environment analysis tool applications
NASA Technical Reports Server (NTRS)
Pack, Ginger L.; Wadsworth, David B.
1994-01-01
Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within it, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.
Product Support Manager Guidebook
2011-04-01
package is being developed using supportability analysis concepts such as Failure Mode, Effects and Criticality Analysis (FMECA), Fault Tree Analysis ( FTA ...Analysis (LORA) Condition Based Maintenance + (CBM+) Fault Tree Analysis ( FTA ) Failure Mode, Effects, and Criticality Analysis (FMECA) Maintenance Task...Reporting and Corrective Action System (FRACAS), Fault Tree Analysis ( FTA ), Level of Repair Analysis (LORA), Maintenance Task Analysis (MTA
Reliability Analysis of Systems Subject to First-Passage Failure
NASA Technical Reports Server (NTRS)
Lutes, Loren D.; Sarkani, Shahram
2009-01-01
An obvious goal of reliability analysis is the avoidance of system failure. However, it is generally recognized that it is often not feasible to design a practical or useful system for which failure is impossible. Thus it is necessary to use techniques that estimate the likelihood of failure based on modeling the uncertainty about such items as the demands on and capacities of various elements in the system. This usually involves the use of probability theory, and a design is considered acceptable if it has a sufficiently small probability of failure. This report contains findings of analyses of systems subject to first-passage failure.
NASA Astrophysics Data System (ADS)
Mahmood, Faleh H.; Kadhim, Hussein T.; Resen, Ali K.; Shaban, Auday H.
2018-05-01
The failure such as air gap weirdness, rubbing, and scrapping between stator and rotor generator arise unavoidably and may cause extremely terrible results for a wind turbine. Therefore, we should pay more attention to detect and identify its cause-bearing failure in wind turbine to improve the operational reliability. The current paper tends to use of power spectral density analysis method of detecting internal race and external race bearing failure in micro wind turbine by estimation stator current signal of the generator. The failure detector method shows that it is well suited and effective for bearing failure detection.
NASA Astrophysics Data System (ADS)
Mulyana, Cukup; Muhammad, Fajar; Saad, Aswad H.; Mariah, Riveli, Nowo
2017-03-01
Storage tank component is the most critical component in LNG regasification terminal. It has the risk of failure and accident which impacts to human health and environment. Risk assessment is conducted to detect and reduce the risk of failure in storage tank. The aim of this research is determining and calculating the probability of failure in regasification unit of LNG. In this case, the failure is caused by Boiling Liquid Expanding Vapor Explosion (BLEVE) and jet fire in LNG storage tank component. The failure probability can be determined by using Fault Tree Analysis (FTA). Besides that, the impact of heat radiation which is generated is calculated. Fault tree for BLEVE and jet fire on storage tank component has been determined and obtained with the value of failure probability for BLEVE of 5.63 × 10-19 and for jet fire of 9.57 × 10-3. The value of failure probability for jet fire is high enough and need to be reduced by customizing PID scheme of regasification LNG unit in pipeline number 1312 and unit 1. The value of failure probability after customization has been obtained of 4.22 × 10-6.
Program Helps In Analysis Of Failures
NASA Technical Reports Server (NTRS)
Stevenson, R. W.; Austin, M. E.; Miller, J. G.
1993-01-01
Failure Environment Analysis Tool (FEAT) computer program developed to enable people to see and better understand effects of failures in system. User selects failures from either engineering schematic diagrams or digraph-model graphics, and effects or potential causes of failures highlighted in color on same schematic-diagram or digraph representation. Uses digraph models to answer two questions: What will happen to system if set of failure events occurs? and What are possible causes of set of selected failures? Helps design reviewers understand exactly what redundancies built into system and where there is need to protect weak parts of system or remove them by redesign. Program also useful in operations, where it helps identify causes of failure after they occur. FEAT reduces costs of evaluation of designs, training, and learning how failures propagate through system. Written using Macintosh Programmers Workshop C v3.1. Can be linked with CLIPS 5.0 (MSC-21927, available from COSMIC).
Practical, transparent prospective risk analysis for the clinical laboratory.
Janssens, Pim Mw
2014-11-01
Prospective risk analysis (PRA) is an essential element in quality assurance for clinical laboratories. Practical approaches to conducting PRA in laboratories, however, are scarce. On the basis of the classical Failure Mode and Effect Analysis method, an approach to PRA was developed for application to key laboratory processes. First, the separate, major steps of the process under investigation are identified. Scores are then given for the Probability (P) and Consequence (C) of predefined types of failures and the chances of Detecting (D) these failures. Based on the P and C scores (on a 10-point scale), an overall Risk score (R) is calculated. The scores for each process were recorded in a matrix table. Based on predetermined criteria for R and D, it was determined whether a more detailed analysis was required for potential failures and, ultimately, where risk-reducing measures were necessary, if any. As an illustration, this paper presents the results of the application of PRA to our pre-analytical and analytical activities. The highest R scores were obtained in the stat processes, the most common failure type in the collective process steps was 'delayed processing or analysis', the failure type with the highest mean R score was 'inappropriate analysis' and the failure type most frequently rated as suboptimal was 'identification error'. The PRA designed is a useful semi-objective tool to identify process steps with potential failures rated as risky. Its systematic design and convenient output in matrix tables makes it easy to perform, practical and transparent. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Ji, Mi Seon; Jeong, Myung Ho; Ahn, Young Keun; Kim, Sang Hyung; Kim, Young Jo; Chae, Shung Chull; Hong, Taek Jong; Seong, In Whan; Chae, Jei Keon; Kim, Chong Jin; Cho, Myeong Chan; Rha, Seung-Woon; Bae, Jang Ho; Seung, Ki Bae; Park, Seung Jung
2016-12-15
It is unclear whether simvastatin-ezetimibe could be an alternative therapy to high-intensity statin therapy in high-risk patients. The aim of this study was to compare the clinical outcomes of simvastatin-ezetimibe and high-intensity statin therapy in patients with acute myocardial infarction (AMI), and especially in those with high-risk factor. A total of 3520 AMI patients in the KAMIR (Korea Acute Myocardial Infarction Registry) were classified into simvastatin-ezetimibe group (n=1249) and high-intensity statin group (n=2271). Multivariate analysis and propensity-score matching analysis were performed. The primary endpoint was major adverse cardiac events (MACE) at 12-months follow-up. In overall AMI patients, MACE occurred in 116 patients (9.3%) in simvastatin-ezetimibe group and 116 patients (5.1%) in high-intensity statin group. The difference in MACE between groups was driven by repeat revascularization (5.9% vs. 2.2%). After propensity matching analysis, simvastatin-ezetimibe was associated with a higher incidence of MACE than high-intensity statin therapy (adjusted hazard ratio: 3.090, 95% confidence interval: 1.715 to 5.566, p<0.001). However, in patients with high-risk factors, such as diabetes, old age, or heart failure, simvastatin-ezetimibe had similar incidence of MACE compared with high-intensity statin therapy in further adjusted analysis. In overall AMI patients, high-intensity statin therapy had better clinical outcomes than simvastatin-ezetimibe. However, in patients with high-risk factor, simvastatin-ezetimibe had comparable clinical outcomes to high-intensity statin therapy. Therefore, simvastatin-ezetimibe could be used as an alternative to high-intensity statin therapy in such patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Gibbel, Mark; Larson, Timothy
2000-01-01
An Engineering-of-Failure approach to designing and executing an accelerated product qualification test was performed to support a risk assessment of a "work-around" necessitated by an on-orbit failure of another piece of hardware on the Mars Global Surveyor spacecraft. The proposed work-around involved exceeding the previous qualification experience both in terms of extreme cold exposure level and in terms of demonstrated low cycle fatigue life for the power shunt assemblies. An analysis was performed to identify potential failure sites, modes and associated failure mechanisms consistent with the new use conditions. A test was then designed and executed which accelerated the failure mechanisms identified by analysis. Verification of the resulting failure mechanism concluded the effort.
NASA Technical Reports Server (NTRS)
2000-01-01
Genoa is a software product that predicts progressive aging and failure in a variety of materials. It is the result of a SBIR contract between the Glenn Research Center and Alpha Star Corporation. Genoa allows designers to determine if the materials they plan on applying to a structure are up to the task or if alternate materials should be considered. Genoa's two feature applications are its progressive failure simulations and its test verification. It allows for a reduction in inspection frequency, rapid design solutions, and manufacturing with low cost materials. It will benefit the aerospace, airline, and automotive industries, with future applications for other uses.
Fusion of approaches to the treatment of organ failure.
Ogle, Brenda; Cascalho, Marilia; Platt, Jeffrey L
2004-01-01
Because organ transplantation is the preferred treatment for organ failure, the demand for human organs for transplantation is large and growing. From this demand, several fields based on new technologies for the replacement or repair of damaged tissues and organs have emerged. These fields include stem cell biology, cloning, tissue engineering and xenotransplantation. Here we evaluate the potential contribution of these to the devising of alternative approaches to organ replacement. We present our vision for the development of two structurally complex organs - the lung and the kidney - based on a 'fusion' of new and established technologies.
Risk analysis of analytical validations by probabilistic modification of FMEA.
Barends, D M; Oldenhof, M T; Vredenbregt, M J; Nauta, M J
2012-05-01
Risk analysis is a valuable addition to validation of an analytical chemistry process, enabling not only detecting technical risks, but also risks related to human failures. Failure Mode and Effect Analysis (FMEA) can be applied, using a categorical risk scoring of the occurrence, detection and severity of failure modes, and calculating the Risk Priority Number (RPN) to select failure modes for correction. We propose a probabilistic modification of FMEA, replacing the categorical scoring of occurrence and detection by their estimated relative frequency and maintaining the categorical scoring of severity. In an example, the results of traditional FMEA of a Near Infrared (NIR) analytical procedure used for the screening of suspected counterfeited tablets are re-interpretated by this probabilistic modification of FMEA. Using this probabilistic modification of FMEA, the frequency of occurrence of undetected failure mode(s) can be estimated quantitatively, for each individual failure mode, for a set of failure modes, and the full analytical procedure. Copyright © 2012 Elsevier B.V. All rights reserved.
Berruyer, M; Atkinson, S; Lebel, D; Bussières, J-F
2016-01-01
Insulin is a high-alert drug. The main objective of this descriptive cross-sectional study was to evaluate the risks associated with insulin use in healthcare centers. The secondary objective was to propose corrective measures to reduce the main risks associated with the most critical failure modes in the analysis. We conducted a failure mode and effects analysis (FMEA) in obstetrics-gynecology, neonatology and pediatrics. Five multidisciplinary meetings occurred in August 2013. A total of 44 out of 49 failure modes were analyzed. Nine out of 44 (20%) failure modes were deemed critical, with a criticality score ranging from 540 to 720. Following the multidisciplinary meetings, everybody agreed that an FMEA was a useful tool to identify failure modes and their relative importance. This approach identified many corrective measures. This shared experience increased awareness of safety issues with insulin in our mother-child center. This study identified the main failure modes and associated corrective measures. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
PAPA, ANDREA ANTONIO; RAGO, ANNA; PETILLO, ROBERTA; D’AMBROSIO, PAOLA; SCUTIFERO, MARIANNA; FEO, MARISA DE; MAIELLO, CIRO; PALLADINO, ALBERTO
2017-01-01
Steinert’s disease or Myotonic Dystrophy type 1 (DM1) is an autosomal dominant multisystemic disorder characterized by myotonia, muscle and facial weakness, cataracts, cognitive, endocrine and gastrointestinal involvement, and cardiac conduction abnormalities. Although mild myocardial dysfunction may be detected in this syndrome with age, overt myocardial dysfunction with heart failure is not frequent. Cardiac resynchronization therapy is an effective treatment to improve morbidity and reduce mortality in patients with DM1 showing intra-ventricular conduction delay and/or congestive heart failure. We report the case of a patient with Steinert disease showing an early onset ventricular dysfunction due to chronic right ventricular apical pacing, in which an epicardial left ventricular lead implantation was performed following the failure of the percutaneous attempt. As no relief in symptoms of heart failure, nor an improvement of left ventricular ejection fraction and reverse remodelling was observed six months later, the patient was addressed to the heart transplantation.
Mechanical Behavior of a Hi-Nicalon(tm)/SiC Composite Having a Polycarbosilane Derived Matrix
NASA Technical Reports Server (NTRS)
Hurwitz, Frances I.; Calomino, Anthony M.; McCue, Terry R.
1999-01-01
Polymer infiltration of a rigidized preform, followed by pyrolysis to convert the polymer to a ceramic, potentially offers a lower cost alternative to CVD. It also offers more moderate temperature requirements than melt infiltration approaches, which should minimize potential fiber damage during processing. However, polymer infiltration and pyrolysis results in a more microcracked matrix. Preliminary mechanical property characterization, including elevated temperature (1204 C) tensile, 500 h stress rupture behavior and low cycle fatigue, was conducted on Hi-Nicalon (TM)/Si-C-(O) composites having a dual layer BN/SiC interface and a matrix derived by impregnation and pyrolysis of allylhydridopolycarbosilane (AHPCS). Microstructural evaluation of failure surfaces and of polished transverse and longitudinal cross sections of the failed specimens was used to identify predominant failure mechanisms. In stress rupture testing at 1093 C, the failure was interface dominated, while at 1204 C in both stress rupture and two hour hold/fatigue tests failure was matrix dominated, resulting in specimen delamination.
NASA Technical Reports Server (NTRS)
Dorris, William J.; Hairr, John W.; Huang, Jui-Tien; Ingram, J. Edward; Shah, Bharat M.
1992-01-01
Non-linear analysis methods were adapted and incorporated in a finite element based DIAL code. These methods are necessary to evaluate the global response of a stiffened structure under combined in-plane and out-of-plane loading. These methods include the Arc Length method and target point analysis procedure. A new interface material model was implemented that can model elastic-plastic behavior of the bond adhesive. Direct application of this method is in skin/stiffener interface failure assessment. Addition of the AML (angle minus longitudinal or load) failure procedure and Hasin's failure criteria provides added capability in the failure predictions. Interactive Stiffened Panel Analysis modules were developed as interactive pre-and post-processors. Each module provides the means of performing self-initiated finite elements based analysis of primary structures such as a flat or curved stiffened panel; a corrugated flat sandwich panel; and a curved geodesic fuselage panel. This module brings finite element analysis into the design of composite structures without the requirement for the user to know much about the techniques and procedures needed to actually perform a finite element analysis from scratch. An interactive finite element code was developed to predict bolted joint strength considering material and geometrical non-linearity. The developed method conducts an ultimate strength failure analysis using a set of material degradation models.
Sherman, Seth L; Copeland, Marilyn E; Milles, Jeffrey L; Flood, David A; Pfeiffer, Ferris M
2016-06-01
To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model. Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading. The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel. Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Education Reform in Mathematics: A History Ignored?
ERIC Educational Resources Information Center
Hofmeister, Alan M.
2004-01-01
Nationally, public education prepares to meet increasing federal and state accountability requirements. This article examines the history of math education reform and concludes that many present national trends do not provide substantive, valid alternatives to past failed practices. The evidence documents a failure to apply fundamental research…
USDA-ARS?s Scientific Manuscript database
Land dynamics, ecosystem resilience, and the interaction of management decisions with them vary significantly across space. One-size-fits-all applications across distinct land types have been responsible for many failures in rangeland management. Ecological Site Descriptions (ESDs) and similar lan...
The Negative Consequences of Teacher Competency Testing.
ERIC Educational Resources Information Center
Gallegos, Arnold M.
1984-01-01
Negative consequences of minimum competency testing for teacher candidates include the waste of human potential resulting from the disproportionately high failure rate of minority teacher candidates and the danger of lessening the pressure for needed curriculum reforms. This essay urges seeking alternative methods for improving the quality of…
Multiple Confidence Estimates as Indices of Eyewitness Memory
ERIC Educational Resources Information Center
Sauer, James D.; Brewer, Neil; Weber, Nathan
2008-01-01
Eyewitness identification decisions are vulnerable to various influences on witnesses' decision criteria that contribute to false identifications of innocent suspects and failures to choose perpetrators. An alternative procedure using confidence estimates to assess the degree of match between novel and previously viewed faces was investigated.…
DOT National Transportation Integrated Search
1995-12-01
Partial failures of aircraft primary flight-control systems and structural : damages to aircraft during flight have led to catastrophic accidents with : subsequent loss of life. These accidents can be prevented if sufficient : alternate control autho...
Practical Help for the Long-Term Learning Disabled Adolescent.
ERIC Educational Resources Information Center
Schirmer, Terry A.; George, Michael P.
1983-01-01
An alternative program offers learning disabled secondary students with histories of academic failure a curriculum emphasizing career awareness and life skills. A work station setup provides experience in such areas as drafting, consumer awareness, mechanics, and transportation. Results include increased attendance, improved self esteem, and…
Thermal Barrier Coatings. Abstracts and figures
NASA Technical Reports Server (NTRS)
1985-01-01
The Thermal Barrier Coatings Workshop was held May 21 and 22, 1985, at the NASA Lewis Research Center in Cleveland, Ohio. Six sessions covered Failure Mechanisms and Life Modeling, Effects of Oxidation and Creep, Phase Stability and Microstructural Aspects, Nondestructive and Analytical Assessment, Coating Development, and Alternative Applications.
Another School is Possible: Learning from Europe
ERIC Educational Resources Information Center
Wrigley, Terry
2005-01-01
In this impassioned attack on the profound failure of the current English system of schooling, Terry Wrigley reminds us of inspirational European alternatives, particularly but not exclusively, from Scandinavia. They not only produce better "results" as measured by international league tables; they also produce better "results"…
Dropout Prevention: An Intervention Model for Today's High Schools.
ERIC Educational Resources Information Center
Maurer, Richard D.
1982-01-01
Describes Project Intercept in Ossining (New York), which cut the high school's dropout, absence, and failure rates by involving teachers, students, and families. The program uses four major strategies--teacher/staff inservice training, alternative academic programs, student training in social and interpersonal skills, and family intervention…
Kadoglou, Nikolaos Pe; Mandila, Christina; Karavidas, Apostolos; Farmakis, Dimitrios; Matzaraki, Vasiliki; Varounis, Christos; Arapi, Sofia; Perpinia, Anastasia; Parissis, John
2017-05-01
Background/design Functional electrical stimulation of lower limb muscles is an alternative method of training in patients with chronic heart failure (CHF). Although it improves exercise capacity in CHF, we performed a randomised, placebo-controlled study to investigate its effects on long-term clinical outcomes. Methods We randomly assigned 120 patients, aged 71 ± 8 years, with stable CHF (New York Heart Association (NYHA) class II/III (63%/37%), mean left ventricular ejection fraction 28 ± 5%), to either a 6-week functional electrical stimulation training programme or placebo. Patients were followed for up to 19 months for death and/or hospitalisation due to CHF decompensation. Results At baseline, there were no significant differences in demographic parameters, CHF severity and medications between groups. During a median follow-up of 383 days, 14 patients died (11 cardiac, three non-cardiac deaths), while 40 patients were hospitalised for CHF decompensation. Mortality did not differ between groups (log rank test P = 0.680), while the heart failure-related hospitalisation rate was significantly lower in the functional electrical stimulation group (hazard ratio (HR) 0.40, 95% confidence interval (CI) 0.21-0.78, P = 0.007). The latter difference remained significant after adjustment for prognostic factors: age, gender, baseline NYHA class and left ventricular ejection fraction (HR 0.22, 95% CI 0.10-0.46, P < 0.001). Compared to placebo, functional electrical stimulation training was associated with a lower occurrence of the composite endpoint (death or heart failure-related hospitalisation) after adjustment for the above-mentioned prognostic factors (HR 0.21, 95% CI 0.103-0.435, P < 0.001). However, that effect was mostly driven by the favourable change in hospitalisation rates. Conclusions In CHF patients, 6 weeks functional electrical stimulation training reduced the risk of heart failure-related hospitalisations, without affecting the mortality rate. The beneficial long-term effects of this alternative method of training require further investigation.
Long-term Follow-up of Revision Osteochondral Allograft Transplantation of the Ankle.
Gaul, Florian; Tírico, Luís E P; McCauley, Julie C; Bugbee, William D
2018-05-01
Osteochondral allograft (OCA) transplantation is a useful alternative for treatment of posttraumatic ankle arthritis in young patients but has a relatively high failure rate and further procedures are often required. The purpose of this study was to evaluate outcomes of patients who underwent revision OCA transplantation of the ankle after failed primary OCA transplantation. Twenty patients underwent revision OCA transplantation of the ankle between 1988 and 2015. Mean age was 44 years, 55% (11 of 20) were female. The mean time from primary to revision OCA was 3.0 ± 1.7 years. All patients had a minimum follow-up of 2 years. Outcomes included the American Academy of Orthopaedic Surgeons Foot and Ankle Module (AAOS-FAM) and questionnaires evaluating pain and satisfaction. Failure of the revision OCA was defined as a conversion to arthroplasty, arthrodesis, or amputation. Ten of 20 ankles required further surgery, of which 30% (6 of 20) were considered OCA revision failures (4 arthrodeses, 1 arthroplasty, and 1 amputation). The mean time to failure was 6.7 (range, 0.6-13.1) years. Survivorship of the revision OCA was 84% at 5 years and 65% at 10 years. The 14 patients with grafts remaining in situ had an average follow-up of 10.3 years; mean AAOS-FAM Core Score was 70.5 (range, 42.3-99). Of the patients who answered the follow-up questions, 4 of 7 reported moderate to severe pain, and 5 of 12 were satisfied with the results of the procedure. Although the results of revision ankle OCA transplantation are not inferior to primary OCA transplantation, the high rates of persistent pain, further surgery, and graft failure suggest that the indications for OCA as a revision procedure should be carefully evaluated, with proper patient selection. Considering the treatment alternatives, revising a failed OCA transplantation can be a useful treatment option, especially for young and active patients who wish to avoid arthrodesis or arthroplasty. Level IV, case series.
Fault management for the Space Station Freedom control center
NASA Technical Reports Server (NTRS)
Clark, Colin; Jowers, Steven; Mcnenny, Robert; Culbert, Chris; Kirby, Sarah; Lauritsen, Janet
1992-01-01
This paper describes model based reasoning fault isolation in complex systems using automated digraph analysis. It discusses the use of the digraph representation as the paradigm for modeling physical systems and a method for executing these failure models to provide real-time failure analysis. It also discusses the generality, ease of development and maintenance, complexity management, and susceptibility to verification and validation of digraph failure models. It specifically describes how a NASA-developed digraph evaluation tool and an automated process working with that tool can identify failures in a monitored system when supplied with one or more fault indications. This approach is well suited to commercial applications of real-time failure analysis in complex systems because it is both powerful and cost effective.
Real-time automated failure analysis for on-orbit operations
NASA Technical Reports Server (NTRS)
Kirby, Sarah; Lauritsen, Janet; Pack, Ginger; Ha, Anhhoang; Jowers, Steven; Mcnenny, Robert; Truong, The; Dell, James
1993-01-01
A system which is to provide real-time failure analysis support to controllers at the NASA Johnson Space Center Control Center Complex (CCC) for both Space Station and Space Shuttle on-orbit operations is described. The system employs monitored systems' models of failure behavior and model evaluation algorithms which are domain-independent. These failure models are viewed as a stepping stone to more robust algorithms operating over models of intended function. The described system is designed to meet two sets of requirements. It must provide a useful failure analysis capability enhancement to the mission controller. It must satisfy CCC operational environment constraints such as cost, computer resource requirements, verification, and validation. The underlying technology and how it may be used to support operations is also discussed.
Fluid removal in acute heart failure: diuretics versus devices.
Krishnamoorthy, Arun; Felker, G Michael
2014-10-01
Fluid removal and relief of congestion are central to treatment of acute heart failure. Diuretics have been the decongestive mainstay but their known limitations have led to the exploration of alternative strategies. This review compares diuretics with ultrafiltration and examines the recent evidence evaluating their use. Relevant recent studies are the Diuretic Optimization Strategies Evaluation trial (of diuretics) and the Cardiorenal Rescue Study in Acute Decompensated Heart Failure (of ultrafiltration). The Diuretic Optimization Strategies Evaluation study evaluated strategies of loop diuretic use during acute heart failure (continuous infusion versus intermittent bolus and high dose versus low dose). After 72 h, there was no significant difference with either comparison for the coprimary end points. Patients treated with a high-dose strategy tended to have greater diuresis and more decongestion compared with low-dose therapy, at the cost of transient changes in renal function. The Cardiorenal Rescue Study in Acute Decompensated Heart Failure study showed that in acute heart failure patients with persistent congestion and worsening renal function, ultrafiltration, as compared with a medical therapy, was associated with similar weight loss but greater increase in serum creatinine and more adverse events. Decongestion remains a major challenge in acute heart failure. Although recent studies provide useful data to guide practice, the relatively poor outcomes point to the continued need to identify better strategies for safe and effective decongestion.
Future research directions to improve fistula maturation and reduce access failure
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J.; Santana, Jeans M.; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R.; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-01-01
With the increasing prevalence of end stage renal disease there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes, in the setting of uremia, systemic inflammation, oxidative stress and preexistent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis, as well as development of neointimal hyperplasia (NIH) that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to NIH involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure, based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure requires a multidisciplinary approach involving nephrologists, vascular surgeons and interventional radiologists, allowing careful patient selection and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. PMID:28779782
Future research directions to improve fistula maturation and reduce access failure.
Hu, Haidi; Patel, Sandeep; Hanisch, Jesse J; Santana, Jeans M; Hashimoto, Takuya; Bai, Hualong; Kudze, Tambudzai; Foster, Trenton R; Guo, Jianming; Yatsula, Bogdan; Tsui, Janice; Dardik, Alan
2016-12-01
With the increasing prevalence of end-stage renal disease, there is a growing need for hemodialysis. Arteriovenous fistulae (AVF) are the preferred type of vascular access for hemodialysis, but maturation and failure continue to present significant barriers to successful fistula use. AVF maturation integrates outward remodeling with vessel wall thickening in response to drastic hemodynamic changes in the setting of uremia, systemic inflammation, oxidative stress, and pre-existent vascular pathology. AVF can fail due to both failure to mature adequately to support hemodialysis and development of neointimal hyperplasia that narrows the AVF lumen, typically near the fistula anastomosis. Failure due to neointimal hyperplasia involves vascular cell activation and migration and extracellular matrix remodeling with complex interactions of growth factors, adhesion molecules, inflammatory mediators, and chemokines, all of which result in maladaptive remodeling. Different strategies have been proposed to prevent and treat AVF failure based on current understanding of the modes and pathology of access failure; these approaches range from appropriate patient selection and use of alternative surgical strategies for fistula creation, to the use of novel interventional techniques or drugs to treat failing fistulae. Effective treatments to prevent or treat AVF failure require a multidisciplinary approach involving nephrologists, vascular surgeons, and interventional radiologists, careful patient selection, and the use of tailored systemic or localized interventions to improve patient-specific outcomes. This review provides contemporary information on the underlying mechanisms of AVF maturation and failure and discusses the broad spectrum of options that can be tailored for specific therapy. Published by Elsevier Inc.
Kosinski, Jan; Gajda, Michal J; Cymerman, Iwona A; Kurowski, Michal A; Pawlowski, Marcin; Boniecki, Michal; Obarska, Agnieszka; Papaj, Grzegorz; Sroczynska-Obuchowicz, Paulina; Tkaczuk, Karolina L; Sniezynska, Paulina; Sasin, Joanna M; Augustyn, Anna; Bujnicki, Janusz M; Feder, Marcin
2005-01-01
In the course of CASP6, we generated models for all targets using a new version of the "FRankenstein's monster approach." Previously (in CASP5) we were able to build many very accurate full-atom models by selection and recombination of well-folded fragments obtained from crude fold recognition (FR) results, followed by optimization of the sequence-structure fit and assessment of alternative alignments on the structural level. This procedure was however very arduous, as most of the steps required extensive visual and manual input from the human modeler. Now, we have automated the most tedious steps, such as superposition of alternative models, extraction of best-scoring fragments, and construction of a hybrid "monster" structure, as well as generation of alternative alignments in the regions that remain poorly scored in the refined hybrid model. We have also included the ROSETTA method to construct those parts of the target for which no reasonable structures were generated by FR methods (such as long insertions and terminal extensions). The analysis of successes and failures of the current version of the FRankenstein approach in modeling of CASP6 targets reveals that the considerably streamlined and automated method performs almost as well as the initial, mostly manual version, which suggests that it may be a useful tool for accurate protein structure prediction even in the hands of nonexperts. 2005 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Karri, Naveen K.; Mo, Changki
2018-06-01
Structural reliability of thermoelectric generation (TEG) systems still remains an issue, especially for applications such as large-scale industrial or automobile exhaust heat recovery, in which TEG systems are subject to dynamic loads and thermal cycling. Traditional thermoelectric (TE) system design and optimization techniques, focused on performance alone, could result in designs that may fail during operation as the geometric requirements for optimal performance (especially the power) are often in conflict with the requirements for mechanical reliability. This study focused on reducing the thermomechanical stresses in a TEG system without compromising the optimized system performance. Finite element simulations were carried out to study the effect of TE element (leg) geometry such as leg length and cross-sectional shape under constrained material volume requirements. Results indicated that the element length has a major influence on the element stresses whereas regular cross-sectional shapes have minor influence. The impact of TE element stresses on the mechanical reliability is evaluated using brittle material failure theory based on Weibull analysis. An alternate couple configuration that relies on the industry practice of redundant element design is investigated. Results showed that the alternate configuration considerably reduced the TE element and metallization stresses, thereby enhancing the structural reliability, with little trade-off in the optimized performance. The proposed alternate configuration could serve as a potential design modification for improving the reliability of systems optimized for thermoelectric performance.
Failure analysis of aluminum alloy components
NASA Technical Reports Server (NTRS)
Johari, O.; Corvin, I.; Staschke, J.
1973-01-01
Analysis of six service failures in aluminum alloy components which failed in aerospace applications is reported. Identification of fracture surface features from fatigue and overload modes was straightforward, though the specimens were not always in a clean, smear-free condition most suitable for failure analysis. The presence of corrosion products and of chemically attacked or mechanically rubbed areas here hindered precise determination of the cause of crack initiation, which was then indirectly inferred from the scanning electron fractography results. In five failures the crack propagation was by fatigue, though in each case the fatigue crack initiated from a different cause. Some of these causes could be eliminated in future components by better process control. In one failure, the cause was determined to be impact during a crash; the features of impact fracture were distinguished from overload fractures by direct comparisons of the received specimens with laboratory-generated failures.
Dubben, H H; Beck-Bornholdt, H P
2000-12-01
The statistical quality of the contributions to "Strahlentherapie und Onkologie" is assessed, aiming for improvement of the journal and consequently its impact factor. All 181 articles published during 1998 and 1999 in the categories "review", "original contribution", and "short communication" were analyzed concerning actuarial analysis of time-failure data. One hundred and twenty-three publications without time-failure data were excluded from analysis. Forty-five of the remaining 58 publications with time-failure data were evaluated actuarially. This corresponds to 78% (95% confidence interval: 64 to 88%) of papers, in which data were adequately analyzed. Complications were reported in 16 of 58 papers, but in only 3 cases actuarially. The number of patients at risk during the course of follow-up was documented adequately in 22 of the 45 publications with actuarial analysis. Authors, peer reviewers, and editors could contribute to improve the quality of the journal by setting value on acturial analysis of time-failure data.
NASA Technical Reports Server (NTRS)
Berry, David M.; Stansberry, Mark
1989-01-01
Using the ANSYS finite element program, a global model of the aft skirt and a detailed nonlinear model of the failure region was made. The analysis confirmed the area of failure in both STA-2B and STA-3 tests as the forging heat affected zone (HAZ) at the aft ring centerline. The highest hoop strain in the HAZ occurs in this area. However, the analysis does not predict failure as defined by ultimate elongation of the material equal to 3.5 percent total strain. The analysis correlates well with the strain gage data from both the Wyle influence test of the original design aft sjirt and the STA-3 test of the redesigned aft skirt. it is suggested that the sensitivity of the failure area material strength and stress/strain state to material properties and therefore to small manufacturing or processing variables is the most likely cause of failure below the expected material ultimate properties.
Specifying design conservatism: Worst case versus probabilistic analysis
NASA Technical Reports Server (NTRS)
Miles, Ralph F., Jr.
1993-01-01
Design conservatism is the difference between specified and required performance, and is introduced when uncertainty is present. The classical approach of worst-case analysis for specifying design conservatism is presented, along with the modern approach of probabilistic analysis. The appropriate degree of design conservatism is a tradeoff between the required resources and the probability and consequences of a failure. A probabilistic analysis properly models this tradeoff, while a worst-case analysis reveals nothing about the probability of failure, and can significantly overstate the consequences of failure. Two aerospace examples will be presented that illustrate problems that can arise with a worst-case analysis.
Study of complete interconnect reliability for a GaAs MMIC power amplifier
NASA Astrophysics Data System (ADS)
Lin, Qian; Wu, Haifeng; Chen, Shan-ji; Jia, Guoqing; Jiang, Wei; Chen, Chao
2018-05-01
By combining the finite element analysis (FEA) and artificial neural network (ANN) technique, the complete prediction of interconnect reliability for a monolithic microwave integrated circuit (MMIC) power amplifier (PA) at the both of direct current (DC) and alternating current (AC) operation conditions is achieved effectively in this article. As a example, a MMIC PA is modelled to study the electromigration failure of interconnect. This is the first time to study the interconnect reliability for an MMIC PA at the conditions of DC and AC operation simultaneously. By training the data from FEA, a high accuracy ANN model for PA reliability is constructed. Then, basing on the reliability database which is obtained from the ANN model, it can give important guidance for improving the reliability design for IC.
NASA Technical Reports Server (NTRS)
Wray, S. T., Jr.
1975-01-01
The LOVES computer code developed to investigate the concept of space servicing operational satellites as an alternative to replacing expendable satellites or returning satellites to earth for ground refurbishment is presented. In addition to having the capability to simulate the expendable satellite operation and the ground refurbished satellite operation, the program is designed to simulate the logistics of space servicing satellites using an upper stage vehicle and/or the earth to orbit shuttle. The program not only provides for the initial deployment of the satellite but also simulates the random failure and subsequent replacement of various equipment modules comprising the satellite. The program has been used primarily to conduct trade studies and/or parametric studies of various space program operational philosophies.
Orbiter subsystem hardware/software interaction analysis. Volume 8: Forward reaction control system
NASA Technical Reports Server (NTRS)
Becker, D. D.
1980-01-01
The results of the orbiter hardware/software interaction analysis for the AFT reaction control system are presented. The interaction between hardware failure modes and software are examined in order to identify associated issues and risks. All orbiter subsystems and interfacing program elements which interact with the orbiter computer flight software are analyzed. The failure modes identified in the subsystem/element failure mode and effects analysis are discussed.
Coelli, Fernando C; Almeida, Renan M V R; Pereira, Wagner C A
2010-12-01
This work develops a cost analysis estimation for a mammography clinic, taking into account resource utilization and equipment failure rates. Two standard clinic models were simulated, the first with one mammography equipment, two technicians and one doctor, and the second (based on an actually functioning clinic) with two equipments, three technicians and one doctor. Cost data and model parameters were obtained by direct measurements, literature reviews and other hospital data. A discrete-event simulation model was developed, in order to estimate the unit cost (total costs/number of examinations in a defined period) of mammography examinations at those clinics. The cost analysis considered simulated changes in resource utilization rates and in examination failure probabilities (failures on the image acquisition system). In addition, a sensitivity analysis was performed, taking into account changes in the probabilities of equipment failure types. For the two clinic configurations, the estimated mammography unit costs were, respectively, US$ 41.31 and US$ 53.46 in the absence of examination failures. As the examination failures increased up to 10% of total examinations, unit costs approached US$ 54.53 and US$ 53.95, respectively. The sensitivity analysis showed that type 3 (the most serious) failure increases had a very large impact on the patient attendance, up to the point of actually making attendance unfeasible. Discrete-event simulation allowed for the definition of the more efficient clinic, contingent on the expected prevalence of resource utilization and equipment failures. © 2010 Blackwell Publishing Ltd.
Memory Circuit Fault Simulator
NASA Technical Reports Server (NTRS)
Sheldon, Douglas J.; McClure, Tucker
2013-01-01
Spacecraft are known to experience significant memory part-related failures and problems, both pre- and postlaunch. These memory parts include both static and dynamic memories (SRAM and DRAM). These failures manifest themselves in a variety of ways, such as pattern-sensitive failures, timingsensitive failures, etc. Because of the mission critical nature memory devices play in spacecraft architecture and operation, understanding their failure modes is vital to successful mission operation. To support this need, a generic simulation tool that can model different data patterns in conjunction with variable write and read conditions was developed. This tool is a mathematical and graphical way to embed pattern, electrical, and physical information to perform what-if analysis as part of a root cause failure analysis effort.
Evaluation of Enhanced Risk Monitors for Use on Advanced Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramuhalli, Pradeep; Veeramany, Arun; Bonebrake, Christopher A.
This study provides an overview of the methodology for integrating time-dependent failure probabilities into nuclear power reactor risk monitors. This prototypic enhanced risk monitor (ERM) methodology was evaluated using a hypothetical probabilistic risk assessment (PRA) model, generated using a simplified design of a liquid-metal-cooled advanced reactor (AR). Component failure data from industry compilation of failures of components similar to those in the simplified AR model were used to initialize the PRA model. Core damage frequency (CDF) over time were computed and analyzed. In addition, a study on alternative risk metrics for ARs was conducted. Risk metrics that quantify the normalizedmore » cost of repairs, replacements, or other operations and management (O&M) actions were defined and used, along with an economic model, to compute the likely economic risk of future actions such as deferred maintenance based on the anticipated change in CDF due to current component condition and future anticipated degradation. Such integration of conventional-risk metrics with alternate-risk metrics provides a convenient mechanism for assessing the impact of O&M decisions on safety and economics of the plant. It is expected that, when integrated with supervisory control algorithms, such integrated-risk monitors will provide a mechanism for real-time control decision-making that ensure safety margins are maintained while operating the plant in an economically viable manner.« less
NASA Astrophysics Data System (ADS)
Zhao, Yong; Yang, Tianhong; Bohnhoff, Marco; Zhang, Penghai; Yu, Qinglei; Zhou, Jingren; Liu, Feiyue
2018-05-01
To quantitatively understand the failure process and failure mechanism of a rock mass during the transformation from open-pit mining to underground mining, the Shirengou Iron Mine was selected as an engineering project case study. The study area was determined using the rock mass basic quality classification method and the kinematic analysis method. Based on the analysis of the variations in apparent stress and apparent volume over time, the rock mass failure process was analyzed. According to the recent research on the temporal and spatial change of microseismic events in location, energy, apparent stress, and displacement, the migration characteristics of rock mass damage were studied. A hybrid moment tensor inversion method was used to determine the rock mass fracture source mechanisms, the fracture orientations, and fracture scales. The fracture area can be divided into three zones: Zone A, Zone B, and Zone C. A statistical analysis of the orientation information of the fracture planes orientations was carried out, and four dominant fracture planes were obtained. Finally, the slip tendency analysis method was employed, and the unstable fracture planes were obtained. The results show: (1) The microseismic monitoring and hybrid moment tensor analysis can effectively analyze the failure process and failure mechanism of rock mass, (2) during the transformation from open-pit to underground mining, the failure type of rock mass is mainly shear failure and the tensile failure is mostly concentrated in the roof of goafs, and (3) the rock mass of the pit bottom and the upper of goaf No. 18 have the possibility of further damage.
NASA Astrophysics Data System (ADS)
Bonachera Martin, Francisco Javier
The characterization of fatigue resistance is one of the main concerns in structural engineering, a concern that is particularly important in the evaluation of existing bridge members designed or erected before the development of fatigue design provisions. The ability of a structural member to develop alternate load paths after the failure of a component is known as member-level or internal redundancy. In fastened built-up members, these alternate load paths are affected by the combination of fastener pre-tension and friction between the structural member components in contact. In this study, a finite element methodology to model and analyze riveted and bolted built-up members was developed in ABAQUS and validated with experimental results. This methodology was used to created finite element models of three fastened plates subjected to tension, in which the middle plate had failed, in order to investigate the fundamental effects of combined fastener pre-tension and friction on their mechanical behavior. Detailed finite element models of riveted and bolted built-up flexural members were created and analyze to understand the effect of fastener pre-tension in member-level redundancy and resistance to fatigue and fracture. The obtained results showed that bolted members are able to re-distribute a larger portion of the load away from the failing component into the rest of the member than riveted members, and that this transfer of load also took place over a smaller length. Superior pre-tension of bolts, in comparison to rivets, results in larger frictional forces that develop at the contact interfaces between components and constitute additional alternate load paths that increase member-level redundancy which increase the fatigue and fracture resistance of the structural member during the failure of one of its components. Although fatigue and fracture potential may be mitigated by compressive stresses developing around the fastener hole due to fastener pre-tension, it was also observed, that at the surface of the fastener hole and at the contact interface with another plate, tensional stresses could develop; however, further computational and experimental work should be performed to verify this claim.
Direct seeding for forestation
Walter H. Davidson
1980-01-01
Direct seeding, an attractive alternative to planting, is not a simple method of forestation. Past experiences show far more failures than successes. Well documented procedures must be followed to insure any degree of success. In general, conifers have given the best results. Black walnut and black locust are notable exceptions. Current research suggests that other...
What's Wrong with Reference: Coping with Success and Failure at the Reference Desk.
ERIC Educational Resources Information Center
Miller, William
1984-01-01
This essay on problems associated with library reference service and personnel discusses the pros and cons of four approaches designed to improve staff utilization and quality of performance--hiring additional staff, automation, alternative staffing arrangements, and planning and rearrangement of priorities. Fourteen sources are given. (EJS)
Changing Attitudes Through Behavior Modification.
ERIC Educational Resources Information Center
Whipple, W. Scott
This article describes the philosophy and methods used by the staff at the Granite Alternative School in changing student attitudes through behavior modification. The students involved all have a failure syndrome or low self-image, and are dropouts from traditional high schools. Among the techniques used are: (1) reinforcing good behavior (praise…
77 FR 43176 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-24
... alternating current (AC) generator failures in-service due to incomplete fusion in the weld joint of the rotor band assembly. This proposed AD would require inspecting the AC generator to determine the part number, and replacing the AC generator if necessary. We are proposing this AD to prevent rotor windings from...
School Exclusion and Educational Inclusion of Pregnant Young Women
ERIC Educational Resources Information Center
Rudoe, Naomi
2014-01-01
This article analyses the school exclusion and subsequent educational inclusion of pregnant young women participating in a course of antenatal and key skills education at an alternative educational setting. It examines the young women's transitions from "failure" in school to "success" in motherhood and re-engagement with…
Intelligence Architecture, Echelons Corps and Below (ECB): Some Near Term Alternatives
1991-04-05
intelligence missions. - Failure to have an annual "MI Table VIII" type evaluation system keeps MI units in the business of supporting other Table...Division) CAC: Combined Arms Center (Ft Leavenworth) CEWI: Combat Electronic Warfare Inteligence C&GSC: Command and General Staff College CI
Sources of Social Control in School: A Speculative Essay.
ERIC Educational Resources Information Center
Schlechty, Phillip C.; Burke, William I.
1980-01-01
This essay attempts to demonstrate that age segregation and subject matter specialization are two important supports of the authority of teachers and the school's ability to control students. Therefore, efforts to change these organizational patterns without considering alternative means of establishing control are doomed to failure. (Author/SJL)
33 CFR 151.1514 - Ballast water management alternatives under extraordinary conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... failure, or other extraordinary conditions, is unable to effect a ballast water exchange before entering... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Ballast water management... SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of...
33 CFR 151.1514 - Ballast water management alternatives under extraordinary conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... failure, or other extraordinary conditions, is unable to effect a ballast water exchange before entering... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Ballast water management... SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of...
Resolving Ethical Disputes Through Arbitration: An Alternative to Code Penalties.
ERIC Educational Resources Information Center
Barwis, Gail Lund
Arbitration cases involving journalism ethics can be grouped into three major categories: outside activities that lead to conflicts of interest, acceptance of gifts that compromise journalistic objectivity, and writing false or misleading information or failing to check facts or correct errors. In most instances, failure to adhere to ethical…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-19
... cause of failures in the electronic processes of the DoD's business enterprise requiring manual... structure that reflects the offeror's business practices for selling and billing commercial items and... sufficient for delivery, payment, and subsequent inventory management of the items delivered. For example...
Understanding and Portraying the Global Atmospheric Circulation.
ERIC Educational Resources Information Center
Harrington, John, Jr.; Oliver, John E.
2000-01-01
Examines teaching models of atmospheric circulation and resultant surface pressure patterns, focusing on the three-cell model and the meaning of meridional circulation as related to middle and high latitudes. Addresses the failure of the three-cell model to explain seasonal variations in atmospheric circulation. Suggests alternative models. (CMK)
Basil Bernstein: Agency, Structure and Linguistic Conception of Class
ERIC Educational Resources Information Center
Best, Shaun
2007-01-01
The paper outlines an interpretation of Bernstein's contribution to the sociology of education that stands in contrast to the common interpretations of Bernstein's work. It is commonly assumed that Bernstein constructed a simplistic "deficit model" of educational failure, or alternatively, that Bernstein was a structuralist who did not give any…
Cultural Assumptions against Sustainability: An International Survey
ERIC Educational Resources Information Center
Gambini, Barbara
2006-01-01
Despite the great progress in increasing public awareness of and attention to the issue of sustainability, the measures taken so far fall dramatically short of halting deleterious cycles. This apparent deficiency can be ascribed to two main factors: insufficient efforts to finding viable and visible alternatives and the failure to thoroughly…
Compression After Impact on Honeycomb Core Sandwich Panels with Thin Facesheets, Part 2: Analysis
NASA Technical Reports Server (NTRS)
Mcquigg, Thomas D.; Kapania, Rakesh K.; Scotti, Stephen J.; Walker, Sandra P.
2012-01-01
A two part research study has been completed on the topic of compression after impact (CAI) of thin facesheet honeycomb core sandwich panels. The research has focused on both experiments and analysis in an effort to establish and validate a new understanding of the damage tolerance of these materials. Part 2, the subject of the current paper, is focused on the analysis, which corresponds to the CAI testings described in Part 1. Of interest, are sandwich panels, with aerospace applications, which consist of very thin, woven S2-fiberglass (with MTM45-1 epoxy) facesheets adhered to a Nomex honeycomb core. Two sets of materials, which were identical with the exception of the density of the honeycomb core, were tested in Part 1. The results highlighted the need for analysis methods which taken into account multiple failure modes. A finite element model (FEM) is developed here, in Part 2. A commercial implementation of the Multicontinuum Failure Theory (MCT) for progressive failure analysis (PFA) in composite laminates, Helius:MCT, is included in this model. The inclusion of PFA in the present model provided a new, unique ability to account for multiple failure modes. In addition, significant impact damage detail is included in the model. A sensitivity study, used to assess the effect of each damage parameter on overall analysis results, is included in an appendix. Analysis results are compared to the experimental results for each of the 32 CAI sandwich panel specimens tested to failure. The failure of each specimen is predicted using the high-fidelity, physicsbased analysis model developed here, and the results highlight key improvements in the understanding of honeycomb core sandwich panel CAI failure. Finally, a parametric study highlights the strength benefits compared to mass penalty for various core densities.
Mechanisms of Diagonal-Shear Failure in Reinforced Concrete Beams analyzed by AE-SiGMA
NASA Astrophysics Data System (ADS)
Ohno, Kentaro; Shimozono, Shinichiro; Sawada, Yosuke; Ohtsu, Masayasu
Serious shear failures in reinforced concrete (RC) structures were reported in the Hanshin-Awaji Earthquake. In particular, it was demonstrated that a diagonal-shear failure could lead to disastrous damage. However, mechanisms of the diagonal-shear failure in RC beams have not been completely clarified yet. In this study, the diagonal-shear failure in RC beams is investigated, applying acoustic emission (AE) method. To identify source mechanisms of AE signals, SiGMA (Simplified Green's functions for Moment tensor Analysis) procedure was applied. Prior to four-point bending tests of RC beams, theoretical waveforms were calculated to determine the optimal arrangement of AE sensors. Then, cracking mechanisms in experiments were investigated by applying the SiGMA procedure to AE waveforms. From results of the SiGMA analysis, dominant motions of micro-cracks are found to be of shear crack in all the loading stages. As the load increased, the number of tensile cracks increased and eventually the diagonal-shear failure occurred in the shear span. Prior to final failure, AE cluster of micro-cracks was intensely observed in the shear span. To classify AE sources into tensile and shear cracks, AE parameter analysis was also applied. As a result, most of AE hits are classified into tensile cracks. The difference between results obtained by the AE parameter analysis and by the SiGMA analysis is investigated and discussed.
Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler
NASA Astrophysics Data System (ADS)
Ghosh, D.; Ray, S.; Mandal, A.; Roy, H.
2015-04-01
This paper highlights a case study of typical premature failure of a radiant platen superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement and chemical analysis, are conducted as part of the investigations. Apart from these, metallographic analysis and fractography are also conducted to ascertain the probable cause of failure. Finally it has been concluded that the premature failure of the super heater tube can be attributed to localized creep at high temperature. The corrective actions has also been suggested to avoid this type of failure in near future.
Failure analysis of stainless steel femur fixation plate.
Hussain, P B; Mohammad, M
2004-05-01
Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
Vianello, Andrea; Savoia, Francesca; Pipitone, Emanuela; Nordio, Beatrice; Gallina, Giulia; Paladini, Luciana; Concas, Alessandra; Arcaro, Giovanna; Gallan, Federico; Pegoraro, Elena
2013-12-01
The "hospital-at-home" model may provide adequate care without an adverse effect on clinical outcome, and is generally well received by users. Our objective was to compare hospital-at-home and in-patient hospital care for neuromuscular disease (NMD) patients with respiratory tract infections. We conducted a prospective randomized controlled trial in a university teaching hospital offering secondary care service to a population of approximately 500,000. We recruited selected NMD patients with respiratory tract infection for whom hospital admission had been recommended after medical assessment. Hospital-at-home was provided as an alternative to in-patient admission. The main outcome measures were need for hospitalization, treatment failure, time to recovery, death during the first 3 months following exacerbation, and cost of patient care. Among 59 consecutive NMD patients eligible for the study, 53 met the criteria for hospital-at-home. Twenty-six subjects were randomized to home care and 27 to hospital care. No significant differences were found in treatment failure (8/26 vs 13/27, P = .19), time to recovery (8.9 ± 4.6 vs 9 ± 8.9 d, P = .21), or mortality at 3 months (3/26 vs 4/27 deaths, P = .42) between the groups. Hospital-at-home failure was independently correlated with type of NMD (P = .004) with an odds ratio of failure of 17.3 (95% CI 2.1 to infinity) for subjects with amyotrophic lateral sclerosis. The total and daily direct cost of patient healthcare was significantly lower for the subjects who were successfully treated at home, compared to the hospitalized individuals. Hospital-at-home is an effective alternative to hospital admission for selected NMD patients with respiratory tract infections.
Clinical review: Helmet and non-invasive mechanical ventilation in critically ill patients.
Esquinas Rodriguez, Antonio M; Papadakos, Peter J; Carron, Michele; Cosentini, Roberto; Chiumello, Davide
2013-04-25
Non-invasive mechanical ventilation (NIV) has proved to be an excellent technique in selected critically ill patients with different forms of acute respiratory failure. However, NIV can fail on account of the severity of the disease and technical problems, particularly at the interface. The helmet could be an alternative interface compared to face mask to improve NIV success. We performed a clinical review to investigate the main physiological and clinical studies assessing the efficacy and related issues of NIV delivered with a helmet. A computerized search strategy of MEDLINE/PubMed (January 2000 to May 2012) and EMBASE (January 2000 to May 2012) was conducted limiting the search to retrospective, prospective, nonrandomized and randomized trials. We analyzed 152 studies from which 33 were selected, 12 physiological and 21 clinical (879 patients). The physiological studies showed that NIV with helmet could predispose to CO₂ rebreathing and increase the patients' ventilator asynchrony. The main indications for NIV were acute cardiogenic pulmonary edema, hypoxemic acute respiratory failure (community-acquired pneumonia, postoperative and immunocompromised patients) and hypercapnic acute respiratory failure. In 9 of the 21 studies the helmet was compared to a face mask during either continous positive airway pressure or pressure support ventilation. In eight studies oxygenation was similar in the two groups, while the intubation rate was similar in four and lower in three studies for the helmet group compared to face mask group. The outcome was similar in six studies. The tolerance was better with the helmet in six of the studies. Although these data are limited, NIV delivered by helmet could be a safe alternative to the face mask in patients with acute respiratory failure.
Burchell, Amy E; Sobotka, Paul A; Hart, Emma C; Nightingale, Angus K; Dunlap, Mark E
2013-06-01
Heart failure is increasing in prevalence around the world, with hospitalization and re-hospitalization as a result of acute decompensated heart failure (ADHF) presenting a huge social and economic burden. The mechanism for this decompensation is not clear. Whilst in some cases it is due to volume expansion, over half of patients with an acute admission for ADHF did not experience an increase in total body weight. This calls into question the current treatment strategy of targeting salt and water retention in ADHF. An alternative hypothesis proposed by Fallick et al. is that an endogenous fluid shift from the splanchnic bed is implicated in ADHF, rather than an exogenous fluid gain. The hypothesis states further that this shift is triggered by an increase in sympathetic tone causing vasoconstriction in the splanchnic bed, a mechanism that can translocate blood rapidly into the effective circulating volume, generating the raised venous pressure and congestion seen in ADHF. This hypothesis encourages a new clinical paradigm which focuses on the underlying mechanisms of congestion, and highlights the importance of fluid redistribution and neurohormonal activation in its pathophysiology. In this article, we consider the concept that ADHF is attributable to episodic sympathetic hyperactivity, resulting in fluid shifts from the splanchnic bed. Chemosensitivity is a pathologic autonomic mechanism associated with mortality in patients with systolic heart failure. Tonic and episodic activity of the peripheral chemoreceptors may underlie the syndrome of acute decompensation without total body salt and water expansion. We suggest in this manuscript that chemosensitivity in response to intermittent hypoxia, such as experienced in sleep disordered breathing, may explain the intermittent sympathetic hyperactivity underlying renal sodium retention and acute volume redistribution from venous storage sites. This hypothesis provides an alternative structure to guide novel diagnostic and treatment strategies for ADHF.
The role of shear and tensile failure in dynamically triggered landslides
Gipprich, T.L.; Snieder, R.K.; Jibson, R.W.; Kimman, W.
2008-01-01
Dynamic stresses generated by earthquakes can trigger landslides. Current methods of landslide analysis such as pseudo-static analysis and Newmark's method focus on the effects of earthquake accelerations on the landslide mass to characterize dynamic landslide behaviour. One limitation of these methods is their use Mohr-Coulomb failure criteria, which only accounts for shear failure, but the role of tensile failure is not accounted for. We develop a limit-equilibrium model to investigate the dynamic stresses generated by a given ground motion due to a plane wave and use this model to assess the role of shear and tensile failure in the initiation of slope instability. We do so by incorporating a modified Griffith failure envelope, which combines shear and tensile failure into a single criterion. Tests of dynamic stresses in both homogeneous and layered slopes demonstrate that two modes of failure exist, tensile failure in the uppermost meters of a slope and shear failure at greater depth. Further, we derive equations that express the dynamic stress in the near-surface in the acceleration measured at the surface. These equations are used to approximately define the depth range for each mechanism of failure. The depths at which these failure mechanisms occur suggest that shear and tensile failure might collaborate in generating slope failure. ?? 2007 The Authors Journal compilation ?? 2007 RAS.
1982-08-23
LUBRICATION, FAILURE PROGRESSION WNITORING OIL-ANALYSIS, FAILURE ANALYSIS, TRIBOLOGY WEAR DEBRIS ANALYSIS, WEAR REGIMS DIAGNOSTICS, BENCH TESTING, FERROGRApHy ...Spectrometric Oil Analysis . ............... 400 G. Analytical Ferrography ............................. 411 3 NAEC-92-153 TABLE OF CONTENTS (Continued...of ferrography entry deposit mnicrographs of these sequences, which can be directly related to sample debris concentration levels. These micrographs
Simulation Assisted Risk Assessment: Blast Overpressure Modeling
NASA Technical Reports Server (NTRS)
Lawrence, Scott L.; Gee, Ken; Mathias, Donovan; Olsen, Michael
2006-01-01
A probabilistic risk assessment (PRA) approach has been developed and applied to the risk analysis of capsule abort during ascent. The PRA is used to assist in the identification of modeling and simulation applications that can significantly impact the understanding of crew risk during this potentially dangerous maneuver. The PRA approach is also being used to identify the appropriate level of fidelity for the modeling of those critical failure modes. The Apollo launch escape system (LES) was chosen as a test problem for application of this approach. Failure modes that have been modeled and/or simulated to date include explosive overpressure-based failure, explosive fragment-based failure, land landing failures (range limits exceeded either near launch or Mode III trajectories ending on the African continent), capsule-booster re-contact during separation, and failure due to plume-induced instability. These failure modes have been investigated using analysis tools in a variety of technical disciplines at various levels of fidelity. The current paper focuses on the development and application of a blast overpressure model for the prediction of structural failure due to overpressure, including the application of high-fidelity analysis to predict near-field and headwinds effects.
[Alternative hemodialysis regimens].
Matos, Jorge Paulo Strogoff de; Lugon, Jocemir Ronaldo
2010-03-01
The mortality rate among patients on hemodialysis (HD) is extremely high. Remaining life expectancy for a patient initiating HD is only approximately one quarter of that of the general population at the same age bracket. The conventional HD regimen based on four-hour sessions three times a week was empirically established nearly four decades ago and needs to be revisited. Since the failure of the HEMO Study to demonstrate the clinical benefits of higher urea Kt/V for patients on conventional HD, an increasing interest for alternative HD regimens has emerged aiming at providing a treatment for improving survival rates. Short daily HD and long nocturnal HD stand out as the most promising alternative regimens. Economical obstacles which could hinder the clinical application of emerging knowledge in the field should be overcome.
The Identification of Software Failure Regions
1990-06-01
be used to detect non-obviously redundant test cases. A preliminary examination of the manual analysis method is performed with a set of programs ...failure regions are defined and a method of failure region analysis is described in detail. The thesis describes how this analysis may be used to detect...is the termination of the ability of a functional unit to perform its required function. (Glossary, 1983) The presence of faults in program code
Failure analysis on optical fiber on swarm flight payload
NASA Astrophysics Data System (ADS)
Bourcier, Frédéric; Fratter, Isabelle; Teyssandier, Florent; Barenes, Magali; Dhenin, Jérémie; Peyriguer, Marie; Petre-Bordenave, Romain
2017-11-01
Failure analysis on optical components is usually carried-out, on standard testing devices such as optical/electronic microscopes and spectrometers, on isolated but representative samples. Such analyses are not contactless and not totally non-invasive, so they cannot be used easily on flight models. Furthermore, for late payload or satellite integration/validation phases with tight schedule issues, it could be necessary to carry out a failure analysis directly on the flight hardware, in cleanroom.
NASA Astrophysics Data System (ADS)
Ke, Jyh-Bin; Lee, Wen-Chiung; Wang, Kuo-Hsiung
2007-07-01
This paper presents the reliability and sensitivity analysis of a system with M primary units, W warm standby units, and R unreliable service stations where warm standby units switching to the primary state might fail. Failure times of primary and warm standby units are assumed to have exponential distributions, and service times of the failed units are exponentially distributed. In addition, breakdown times and repair times of the service stations also follow exponential distributions. Expressions for system reliability, RY(t), and mean time to system failure, MTTF are derived. Sensitivity analysis, relative sensitivity analysis of the system reliability and the mean time to failure, with respect to system parameters are also investigated.
Nitrile O-ring Cracking: A Case of Vacuum Flange O-ring Failures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dees, Craig
2016-07-01
A review of recent nitrile O-ring failures in ISO-KF vacuum flange connections in glovebox applications is presented. An investigation of a single “isolated” o-ring failure leads to the discovery of cracked nitrile o-rings in a glovebox atmospheric control unit. The initial cause of the o-ring failure is attributed to ozone degradation. However, additional investigation reveals nitrile o-ring cracking on multiple gloveboxes and general purpose piping, roughly 85% of the nitrile o-rings removed for inspection show evidence of visible cracking after being in service for 18 months or less. The results of material testing and ambient air testing is presented, elevatedmore » ozone levels are not found. The contributing factors of o-ring failure, including nitrile air sensitivity, inadequate storage practices, and poor installation techniques, are discussed. A discussion of nitrile o-ring material properties, the benefits and limitations, and alternate materials are discussed. Considerations for o-ring material selection, purchasing, storage, and installation are presented in the context of lessons learned from the nitrile o-ring cracking investigation. This paper can be presented in 20 minutes and does not require special accommodations or special audio visual devices.« less
X-framework: Space system failure analysis framework
NASA Astrophysics Data System (ADS)
Newman, John Steven
Space program and space systems failures result in financial losses in the multi-hundred million dollar range every year. In addition to financial loss, space system failures may also represent the loss of opportunity, loss of critical scientific, commercial and/or national defense capabilities, as well as loss of public confidence. The need exists to improve learning and expand the scope of lessons documented and offered to the space industry project team. One of the barriers to incorporating lessons learned include the way in which space system failures are documented. Multiple classes of space system failure information are identified, ranging from "sound bite" summaries in space insurance compendia, to articles in journals, lengthy data-oriented (what happened) reports, and in some rare cases, reports that treat not only the what, but also the why. In addition there are periodically published "corporate crisis" reports, typically issued after multiple or highly visible failures that explore management roles in the failure, often within a politically oriented context. Given the general lack of consistency, it is clear that a good multi-level space system/program failure framework with analytical and predictive capability is needed. This research effort set out to develop such a model. The X-Framework (x-fw) is proposed as an innovative forensic failure analysis approach, providing a multi-level understanding of the space system failure event beginning with the proximate cause, extending to the directly related work or operational processes and upward through successive management layers. The x-fw focus is on capability and control at the process level and examines: (1) management accountability and control, (2) resource and requirement allocation, and (3) planning, analysis, and risk management at each level of management. The x-fw model provides an innovative failure analysis approach for acquiring a multi-level perspective, direct and indirect causation of failures, and generating better and more consistent reports. Through this approach failures can be more fully understood, existing programs can be evaluated and future failures avoided. The x-fw development involved a review of the historical failure analysis and prevention literature, coupled with examination of numerous failure case studies. Analytical approaches included use of a relational failure "knowledge base" for classification and sorting of x-fw elements and attributes for each case. In addition a novel "management mapping" technique was developed as a means of displaying an integrated snapshot of indirect causes within the management chain. Further research opportunities will extend the depth of knowledge available for many of the component level cases. In addition, the x-fw has the potential to expand the scope of space sector lessons learned, and contribute to knowledge management and organizational learning.
Determination of UAV pre-flight Checklist for flight test purpose using qualitative failure analysis
NASA Astrophysics Data System (ADS)
Hendarko; Indriyanto, T.; Syardianto; Maulana, F. A.
2018-05-01
Safety aspects are of paramount importance in flight, especially in flight test phase. Before performing any flight tests of either manned or unmanned aircraft, one should include pre-flight checklists as a required safety document in the flight test plan. This paper reports on the development of a new approach for determination of pre-flight checklists for UAV flight test based on aircraft’s failure analysis. The Lapan’s LSA (Light Surveillance Aircraft) is used as a study case, assuming this aircraft has been transformed into the unmanned version. Failure analysis is performed on LSA using fault tree analysis (FTA) method. Analysis is focused on propulsion system and flight control system, which fail of these systems will lead to catastrophic events. Pre-flight checklist of the UAV is then constructed based on the basic causes obtained from failure analysis.
NASA Astrophysics Data System (ADS)
Hughes, Allen A.
1994-12-01
Public safety can be enhanced through the development of a comprehensive medical device risk management. This can be accomplished through case studies using a framework that incorporates cost-benefit analysis in the evaluation of risk management attributes. This paper presents a framework for evaluating the risk management system for regulatory Class III medical devices. The framework consists of the following sixteen attributes of a comprehensive medical device risk management system: fault/failure analysis, premarket testing/clinical trials, post-approval studies, manufacturer sponsored hospital studies, product labeling, establishment inspections, problem reporting program, mandatory hospital reporting, medical literature surveillance, device/patient registries, device performance monitoring, returned product analysis, autopsy program, emergency treatment funds/interim compensation, product liability, and alternative compensation mechanisms. Review of performance histories for several medical devices can reveal the value of information for many attributes, and also the inter-dependencies of the attributes in generating risk information flow. Such an information flow network is presented as a starting point for enhancing medical device risk management by focusing on attributes with high net benefit values and potential to spur information dissemination.
Yoo, Tae Yeon; Adhikari, Aashish; Xia, Zhen; Huynh, Tien; Freed, Karl F.; Zhou, Ruhong; Sosnick, Tobin R.
2012-01-01
Progress in understanding protein folding relies heavily upon an interplay between experiment and theory. In particular, readily interpretable experimental data are required that can be meaningfully compared to simulations. According to standard mutational φ analysis, the transition state for Protein L contains only a single hairpin. However, we demonstrate here using ψ analysis with engineered metal ion binding sites that the transition state is extensive, containing the entire four-stranded β sheet. Underreporting of the structural content of the transition state by φ analysis also occurs for acyl phosphatase1, ubiquitin2 and BdpA3. The carboxy terminal hairpin in the transition state of Protein L is found to be non-native, a significant result that agrees with our PDB-based backbone sampling and all-atom simulations. The non-native character partially explains the failure of accepted experimental and native-centric computational approaches to adequately describe the transition state. Hence, caution is required even when an apparent agreement exists between experiment and theory, thus highlighting the importance of having alternative methods for characterizing transition states. PMID:22522126
Alternative Radioisotopes for Heat and Power Sources
NASA Astrophysics Data System (ADS)
Tinsley, T.; Sarsfield, M.; Rice, T.
Production of 238Pu requires considerable facilities including a nuclear reactor and reprocessing plants that are very expensive to build and operate. Thus, a more economical alternative is very attractive to the industry. There are many alternative radioisotopes that exist but few that satisfy the criteria of performance, availability and cost to produce. Any alternative to 238Pu must exist in a chemical form that is compatible with the materials required to safely encapsulate the heat source at the high temperatures of operation and potential launch failure scenarios. The chemical form must also have suitable thermal properties to ensure maximum energy conversion efficiencies when integrated into radioisotope thermoelectric generators over the required mission durations. In addition, the radiation dose must be low enough for operators during production and not so prohibitive that excessive shielding mass is required on the space craft. This paper will focus on the preferred European alternative of 241Am, and the issues that will need to be addressed.
Failure analysis and modeling of a VAXcluster system
NASA Technical Reports Server (NTRS)
Tang, Dong; Iyer, Ravishankar K.; Subramani, Sujatha S.
1990-01-01
This paper discusses the results of a measurement-based analysis of real error data collected from a DEC VAXcluster multicomputer system. In addition to evaluating basic system dependability characteristics such as error and failure distributions and hazard rates for both individual machines and for the VAXcluster, reward models were developed to analyze the impact of failures on the system as a whole. The results show that more than 46 percent of all failures were due to errors in shared resources. This is despite the fact that these errors have a recovery probability greater than 0.99. The hazard rate calculations show that not only errors, but also failures occur in bursts. Approximately 40 percent of all failures occur in bursts and involved multiple machines. This result indicates that correlated failures are significant. Analysis of rewards shows that software errors have the lowest reward (0.05 vs 0.74 for disk errors). The expected reward rate (reliability measure) of the VAXcluster drops to 0.5 in 18 hours for the 7-out-of-7 model and in 80 days for the 3-out-of-7 model.
A Comparison of Functional Models for Use in the Function-Failure Design Method
NASA Technical Reports Server (NTRS)
Stock, Michael E.; Stone, Robert B.; Tumer, Irem Y.
2006-01-01
When failure analysis and prevention, guided by historical design knowledge, are coupled with product design at its conception, shorter design cycles are possible. By decreasing the design time of a product in this manner, design costs are reduced and the product will better suit the customer s needs. Prior work indicates that similar failure modes occur with products (or components) with similar functionality. To capitalize on this finding, a knowledge base of historical failure information linked to functionality is assembled for use by designers. One possible use for this knowledge base is within the Elemental Function-Failure Design Method (EFDM). This design methodology and failure analysis tool begins at conceptual design and keeps the designer cognizant of failures that are likely to occur based on the product s functionality. The EFDM offers potential improvement over current failure analysis methods, such as FMEA, FMECA, and Fault Tree Analysis, because it can be implemented hand in hand with other conceptual design steps and carried throughout a product s design cycle. These other failure analysis methods can only truly be effective after a physical design has been completed. The EFDM however is only as good as the knowledge base that it draws from, and therefore it is of utmost importance to develop a knowledge base that will be suitable for use across a wide spectrum of products. One fundamental question that arises in using the EFDM is: At what level of detail should functional descriptions of components be encoded? This paper explores two approaches to populating a knowledge base with actual failure occurrence information from Bell 206 helicopters. Functional models expressed at various levels of detail are investigated to determine the necessary detail for an applicable knowledge base that can be used by designers in both new designs as well as redesigns. High level and more detailed functional descriptions are derived for each failed component based on NTSB accident reports. To best record this data, standardized functional and failure mode vocabularies are used. Two separate function-failure knowledge bases are then created aid compared. Results indicate that encoding failure data using more detailed functional models allows for a more robust knowledge base. Interestingly however, when applying the EFDM, high level descriptions continue to produce useful results when using the knowledge base generated from the detailed functional models.
Baqui, Abdullah H; Saha, Samir K; Ahmed, A S M Nawshad Uddin; Shahidullah, Mohammad; Quasem, Iftekhar; Roth, Daniel E; Samsuzzaman, A K M; Ahmed, Wazir; Tabib, S M Shahnawaz Bin; Mitra, Dipak K; Begum, Nazma; Islam, Maksuda; Mahmud, Arif; Rahman, Mohammad Hefzur; Moin, Mamun Ibne; Mullany, Luke C; Cousens, Simon; El Arifeen, Shams; Wall, Stephen; Brandes, Neal; Santosham, Mathuram; Black, Robert E
2015-05-01
Severe infections remain one of the main causes of neonatal deaths worldwide. Possible severe infection is diagnosed in young infants (aged 0-59 days) according to the presence of one or more clinical signs. The recommended treatment is hospital admission with 7-10 days of injectable antibiotic therapy. In low-income and middle-income countries, barriers to hospital care lead to delayed, inadequate, or no treatment for many young infants. We aimed to identify effective alternative antibiotic regimens to expand treatment options for situations where hospital admission is not possible. We did this randomised, open-label, equivalence trial in four urban hospitals and one rural field site in Bangladesh to determine whether two alternative antibiotic regimens with reduced numbers of injectable antibiotics combined with oral antibiotics had similar efficacy and safety to the standard regimen, which was also used as outpatient treatment. We randomly assigned infants who showed at least one clinical sign of severe, but not critical, infection (except fast breathing alone), whose parents refused hospital admission, to one of the three treatment regimens. We stratified randomisation by study site and age (<7 days or 7-59 days) using computer-generated randomisation sequences. The standard treatment was intramuscular procaine benzylpenicillin and gentamicin once per day for 7 days (group A). The alternative regimens were intramuscular gentamicin once per day and oral amoxicillin twice per day for 7 days (group B) or intramuscular procaine benzylpenicillin and gentamicin once per day for 2 days, then oral amoxicillin twice per day for 5 days (group C). The primary outcome was treatment failure within 7 days after enrolment. Assessors of treatment failure were masked to treatment allocation. Primary analysis was per protocol. We used a prespecified similarity margin of 5% to assess equivalence between regimens. This study is registered with ClinicalTrials.gov, number NCT00844337. Between July 1, 2009, and June 30, 2013, we recruited 2490 young infants into the trial. We assigned 830 infants to group A, 831 infants to group B, and 829 infants to group C. 2367 (95%) infants fulfilled per-protocol criteria. 78 (10%) of 795 per-protocol infants had treatment failure in group A compared with 65 (8%) of 782 infants in group B (risk difference -1.5%, 95% CI -4.3 to 1.3) and 64 (8%) of 790 infants in group C (-1.7%, -4.5 to 1.1). In group A, 14 (2%) infants died before day 15, compared with 12 (2%) infants in group B and 12 (2%) infants in group C. Non-fatal relapse rates were similar in all three groups (12 [2%] infants in group A vs 13 [2%] infants in group B and 10 [1%] infants in group C). Our results suggest that the two alternative antibiotic regimens for outpatient treatment of clinical signs of severe infection in young infants whose parents refused hospital admission are as efficacious as the standard regimen. This finding could increase treatment options in resource-poor settings when referral care is not available or acceptable. Copyright © 2015 Baqui et al. Open Access article distributed under the terms of CC BY. Published by .. All rights reserved.
NASA Astrophysics Data System (ADS)
Simuel, Gloria J.
Heart Failure continues to be a major public health problem associated with high mortality and morbidity. Heart Failure is the leading cause of hospitalization for persons older than 65 years, has a poor prognosis and is associated with poor quality of life. More than 5.3 million American adults are living with heart failure. Despite maximum medical therapy and frequent hospitalizations to stabilize their condition, one in five heart failure patients die within the first year of diagnosis. Several disease-management programs have been proposed and tested to improve the quality of heart failure care. Studies have shown that hospital admissions and emergency room visits decrease with increased nursing interventions in the home and community setting. An alternative strategy for promoting self-management of heart failure is the use of electronic home monitoring. The purpose of this study was to examine what effects heart failure has on patient's quality of life that had been monitoring on an electronic home monitor longer than 2 months. Twenty-one questionnaires were given to patients utilizing an electronic home monitor by their home health agency nurse. Eleven patients completed the questionnaire. The findings showed that there is some deterioration in quality of life with more association with the physical aspects of life than with the emotional aspects of life, which probably was due to the small sample size. There was no significant difference in readmission rates in patients utilizing an electronic home monitor. Further research is needed with a larger population of patients with chronic heart failure and other chronic diseases which may provide more data, and address issues such as patient compliance with self-care, impact of heart failure on patient's quality of life, functional capacity, and heart failure patient's utilization of the emergency rooms and hospital. Telemonitoring holds promise for improving the self-care abilities of persons with HF.
NASA Technical Reports Server (NTRS)
Wanthal, Steven; Schaefer, Joseph; Justusson, Brian; Hyder, Imran; Engelstad, Stephen; Rose, Cheryl
2017-01-01
The Advanced Composites Consortium is a US Government/Industry partnership supporting technologies to enable timeline and cost reduction in the development of certified composite aerospace structures. A key component of the consortium's approach is the development and validation of improved progressive damage and failure analysis methods for composite structures. These methods will enable increased use of simulations in design trade studies and detailed design development, and thereby enable more targeted physical test programs to validate designs. To accomplish this goal with confidence, a rigorous verification and validation process was developed. The process was used to evaluate analysis methods and associated implementation requirements to ensure calculation accuracy and to gage predictability for composite failure modes of interest. This paper introduces the verification and validation process developed by the consortium during the Phase I effort of the Advanced Composites Project. Specific structural failure modes of interest are first identified, and a subset of standard composite test articles are proposed to interrogate a progressive damage analysis method's ability to predict each failure mode of interest. Test articles are designed to capture the underlying composite material constitutive response as well as the interaction of failure modes representing typical failure patterns observed in aerospace structures.
Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee C. Cadwallader
2010-06-01
This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.
Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee C. Cadwallader
2007-08-01
This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.
Flight Data Analysis of HyShot 2
NASA Technical Reports Server (NTRS)
Hass, Neal E.; Smart, Michael K.; Paull, Alan
2005-01-01
The development of scramjet propulsion for alternative launch and payload delivery capabilities has comprised largely of ground experiments for the last 40 years. With the goal of validating the use of short duration ground test facilities, the University of Queensland, supported by a large international contingency, devised a ballistic re-entry vehicle experiment called HyShot to achieve supersonic combustion in flight above Mach 7.5. It consisted of a double wedge intake and two back-to-back constant area combustors; one supplied with hydrogen fuel at an equivalence ratio of 0.33 and the other un-fueled. Following a first launch failure on October 30th 2001, the University of Queensland conducted a successful second launch on July 30th, 2002. Post-flight data analysis of the second launch confirmed the presence of supersonic combustion during the approximately 3 second test window at altitudes between 35 and 29 km. Reasonable correlation between flight and some pre-flight shock tunnel tests was observed.
Yazdi, Mohammad; Korhan, Orhan; Daneshvar, Sahand
2018-05-09
This study aimed at establishing fault tree analysis (FTA) using expert opinion to compute the probability of an event. To find the probability of the top event (TE), all probabilities of the basic events (BEs) should be available when the FTA is drawn. In this case, employing expert judgment can be used as an alternative to failure data in an awkward situation. The fuzzy analytical hierarchy process as a standard technique is used to give a specific weight to each expert, and fuzzy set theory is engaged for aggregating expert opinion. In this regard, the probability of BEs will be computed and, consequently, the probability of the TE obtained using Boolean algebra. Additionally, to reduce the probability of the TE in terms of three parameters (safety consequences, cost and benefit), the importance measurement technique and modified TOPSIS was employed. The effectiveness of the proposed approach is demonstrated with a real-life case study.
Brondani, Lucas Pradebon; Pereira-Cenci, Tatiana; Wandsher, Vinicius Felipe; Pereira, Gabriel Kalil; Valandro, Luis Felipe; Bergoli, César Dalmolin
2017-04-10
Resin cements are often used for single crown cementation due to their physical properties. Self-adhesive resin cements gained widespread due to their simplified technique compared to regular resin cement. However, there is lacking clinical evidence about the long-term behavior of this material. The aim of this prospective clinical trial was to assess the survival rates of metal-ceramic crowns cemented with self-adhesive resin cement up to six years. One hundred and twenty-nine subjects received 152 metal-ceramic crowns. The cementation procedures were standardized and performed by previously trained operators. The crowns were assessed as to primary outcome (debonding) and FDI criteria. Statistical analysis was performed using Kaplan-Meier statistics and descriptive analysis. Three failures occurred (debonding), resulting in a 97.6% survival rate. FDI criteria assessment resulted in scores 1 and 2 (acceptable clinical evaluation) for all surviving crowns. The use of self-adhesive resin cement is a feasible alternative for metal-ceramic crowns cementation, achieving high and adequate survival rates.
Beyond FMEA: the structured what-if technique (SWIFT).
Card, Alan J; Ward, James R; Clarkson, P John
2012-01-01
Although it is probably the best-known prospective hazard analysis (PHA) tool, failure mode and effects analysis (FMEA) is far from the only option available. This article introduces one of the alternatives: The structured what-if technique (SWIFT). SWIFT is a flexible, high-level risk identification technique that can be used on a stand-alone basis, or as part of a staged approach to make more efficient use of bottom-up methods like FMEA. In this article we describe the method, assess the evidence related to its use in healthcare with the use of a systematic literature review, and suggest ways in which it could be better adapted for use in the healthcare industry. Based on the limited evidence available, it appears that healthcare workers find it easy to learn, easy to use, and credible. Especially when used as part of a staged approach, SWIFT appears capable of playing a useful role as component of the PHA armamentarium. © 2012 American Society for Healthcare Risk Management of the American Hospital Association.
Ferrographic and spectrographic analysis of oil sampled before and after failure of a jet engine
NASA Technical Reports Server (NTRS)
Jones, W. R., Jr.
1980-01-01
An experimental gas turbine engine was destroyed as a result of the combustion of its titanium components. Several engine oil samples (before and after the failure) were analyzed with a Ferrograph as well as plasma, atomic absorption, and emission spectrometers. The analyses indicated that a lubrication system failure was not a causative factor in the engine failure. Neither an abnormal wear mechanism, nor a high level of wear debris was detected in the oil sample from the engine just prior to the test in which the failure occurred. However, low concentrations of titanium were evident in this sample and samples taken earlier. After the failure, higher titanium concentrations were detected in oil samples taken from different engine locations. Ferrographic analysis indicated that most of the titanium was contained in spherical metallic debris after the failure.